HomeMy WebLinkAboutEVALUATION REPORTWWI EVALUATION REPORT TRI-BUILT Materials Group, LLC PO Box 70 Rutherford, NJ 07070 (800)516-1485 SCANNED BY St. Lucie County EXTERIOR RESEARCH & DESIGN, LLC. Certificate of Authorization #9503 353 Christian Street Oxford, CT 06478 (203)262-924S Evaluation Report A42970.10.12-R2 FL16027-R2 Date of Issuance:10/23/2012 Revision 2: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for compliance with the 6th Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinityl ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix Prepared by: Robert J.M. Nieminen, P.E. Thelacaimilexealappeanny•vasauronzeab,R.benN4minen. Florida Registration No. 59166, Florida DCA ANE1983 '�S='^u== ,' p.Lon09125/2017 This apaa npuarve asap eieceromcanvaiynaa document. CERTIFICATION OF INDEPENDENCE: 1. Exterior Research & Design, LLC. d/b/a Trinity I ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or cistributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. r TRINITY ERD ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Modified Bitumen Roof Systems Compliance Statement: TRI-BUILT Modified Bitumen Roof Systems, as produced by TRI-BUILT Materials Group, LLC, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1 Wind FM 4474 2011 1504.7 Impact FM 4470 2012 1507.11.2 Physical Properties ASTM D6163 2008 1507.11.2 Physical Properties ASTM D6164 2011 1507.11.2 Physical Properties ASTM D6222 2011 3. REFERENCES Entity Examination Reference Date ERD (TST6049) Physical Properties P10490.10.08-2 10/30/2008 ERD (TST6049) FM 4470/4474 P13760.09.09 09/10/2009 ERD (TST6049) FM 4470/4474 P13770.09.09 09/10.,2009 ERD (TST6049) FM 4470/4474 P30540.11.09-R1 11/30/2009 ERD (TST6049) FM 4470/4474 P30550.12.09 12/02/2009 ERD (TST6049) Physical Properties P33960.12.10 12/30/2010 ERD (TST6049) FM 4470/4474 P33970.03.11 03/15/2011 ERD (TST6049) Physical Properties 1`37590.03.13-3A 03/06/2013 ERD (TST6049) FM 4470/4474 P39680.03.13 03/04/2013 ERD (TST6049) Physical Properties P37590.03.13-1-R1 06/26/2013 ERD (TST6049) Physical Properties P37590.03.13-2-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-2 07/01/2013 ERD (TST6049) Physical Properties P37590.03.13-5-R1 07/01/2013 ERD (TST6049) Physical Properties P37590.07.13-1 07/02/2013 ERD (TST6049) Physical Properties P45940.09.13 09/04/2013 ERD (TST6049) Physical Properties P44370.10.13 10/04/2013 FM Approvals (TST1867) FM 4470 2W7A7.AM 08/04/1994 FM Approvals (TST1867) FM 4470 OD3A3.AM 04/04/1997 FM Approvals (TST1867) FM 4470 2DOAO.AM 12/23/1998 FM Approvals (TST1867) FM 4470 2D5A9.AM 06/22/1999 FM Approvals (TST1867) FM 4470 3006646 01/04/2000 FM Approvals (TST1867) FM 4470 3001334 01/25/2000 FM Approvals (TST1867) FM 4470 3001334 02/15/2000 FM Approvals (TST1867) FM 4470 3000857 01/12/2000 FM Approvals (TST1867) FM 4470 3004091 01/12/2000 FM Approvals (TST1867) FM 4470 3006115 OS/02/2001 FM Approvals (TST1867) FM 4470 3012321 07/29/2002 FM Approvals (TST1867) FM 4470 3014692 08/05/2003 FM Approvals (TST1867) FM 4470 3014751 08/27/2003 FM Approvals (TST1867) FM 4470 3007170 01/13/2004 FM Approvals(TST1867) FM 4470 3019317 06/30/2004 FM Approvals (TST1867) FM 4470 3020703 07/30/2004 FM Approvals (TST1867) FM 4470/4474 3018332 01/31/2006 FM Approvals (TST1867) FM 4470/4474 3023368 03/20/2006 FM Approvals (TST1867) FM 4470/4474 3024594 05/23/2006 Exterior Research and Design, H.C. Evaluation Report A42970.10.12-112 certificate ofAathorization#5503 6"EDIT10N(20171 FBC N D N. HVH 2 EVALUATI ON FL36027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 2 of 4 Katty Examination Reference FM Approvals(TST1867) FM 4470/4474 3023458 FM Approvals(TST1867) FM 4470/4474 3030668 FM Approvals(TST1867) FM 4470/4474 3032172 PRI (TST5878) Physical Properties PUSA-062-02-01 PRI TST5878) Physical Properties PUSA-061-02-02 PRI (TST5878) Physical Properties PUSA-064-02-02 PRI (TST5878) Physical Properties PUSA-062-02-02 Miami-Dade(CER1592) HVHZCompliance Various NOAs Miami -Dade (CER1592) Proposal for Review 30-0823 ULLLC (QUA9625) Quality Control ML Agreement UL LLC (QUA9625) Quality Control ML Correlation, R27202 UL LLC (QUA9625) Quality Control Service Confirmation, R14571 4. PRODUcr DESCRIPTION: TRINITY ERD Date 07/18/2006_ 09/12/2007 06/12/2009 12/04/2007 01/28/2008 02/27/2008 12/04/2008 Various 10/12/2010 02/27/2012 08/20/2012 Exp. 10/06/2018 This Evaluation Report covers TRI-BUILT Modified Bitumen Roof Systems installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions and the Limitations / Conditions of Use herein. The following membranes make up the subject systems. Table 1: Roll-Goods,for TRI=BUILT Modified Bitumen Roof Systems Type Product Specification Reference Grade Type SBS Membranes TriBuilt SA SBS Base ASTM D6163, Table 2 S I TriBuilt SBS Granular ASTM D6164 G I TriBuilt SA SBS Cap ASTM D6164 6 I APP Membranes TriBuilt APP Smooth ASTM D6222 S I TriBuilt APP Granular ASTM D6222 G TriBuilt SA APP Cap ASTM D6222 G 1 S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity IERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Refer to a current Approved Roofing Materials Directory for fire ratings of this product. 5.4 For steel deck installations, foam plastic insulation shall be separated from the building interior in accordance with FBC 2603.4 unless the exceptions stated in FBC 2603.4.1 and 2603.6 apply. 5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 5.6 For recover installations, the existing roof shall be examined in accordance with FBC 1511. 5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. Exterior Research and Design, LLC. Evaluation Report A42970.10.12-RZ certificate ofAuthorizoHon 99503 o'"EDITION I2017j FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 3 of 4 TRINITY ERD 5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No rational analysis is permitted for these systems. 5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the existing deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. If any surface conditions exist that bring system performance into question, field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124 shall be conducted on mock-ups of the proposed new roof assembly. 5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof system shall be capable of resisting project design pressures on its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with FBC Chapter 16 and tested for resistance in accordance with ANSI/SPRI ES-1 or Roofing Application Standard RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or 1609.3(3). 5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3. 6. INSTALLATION: �. 6.1 TRI-BUILT Modified Bitumen Roof Systems shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation instructions, subject to the Limitations / Conditions of Use noted below. 6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FBC 1609 for determination of design wind loads. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 8. MANUFACTURING PLANTS: Contact the noted QA agency for information on product locations covered for F.A.C. Rule 61G20-3 QA requirements. 9.. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (314) 578-3406, k.chancellor@us.ul.com -THE26-PAGES THAT FOLLOW FORM PART OF THIS EVALUATION REPORT - Exterior Research and Design, I.I.C. Evaluation Report A42970.10.12-RZ Certificate of Authori:adon#9503 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL16027-R2 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Revision 2: 09/25/2017 Page 4 of 4 TRINI-IY ERD rAPPENDI%S: ATTACHMENT REQUIflEMENiS FOR WIND UPLIFT RESISTANCE' Table Deck Application Type Description Page IA-1 Wood New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 4 1A-2 Wood New, Reroof (Tear -Off) or.Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover - 5 SB Wood New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 5 1C Wood New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 6 ID Wood New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 6 1E-1 Wood New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 7 ;01E — _ Wood_ _ New, Reroof (Tear -Off) or Recover E N -In rated Mecb-Attach B sP Sheet, Bdnded Roof Cover. �n RF _ Wood New or Reroof (Tear- F Non -Insulated, B nded Roof Cover 2A Steel or Structural con a ew, Reroof (Tear -Off) or Recover B Mech. A[[ac ed Base Insulation, op Insu anon, Bonded Roof Cover 9 2B Steel or5tructural concrete New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 9 2C Steel or Structural concrete New, Reroof (Tear -Off) or Recover D Prelim. Attached Insulation, Mech. Attached Base Sheet, Bonded Roof Cover 10 3A Structural concrete New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 11-14 36 Structural concrete New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 14 4A LWIC New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 15-16 4B LWIC New or Reroof (Tear -Off) A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 16 4C LWIC New or Reroof (Tear -Off) E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 17-19 SA CWF New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 20 5B CWF New, Reroof (Tear -Off) or Recover A-2 Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 21 SC CWF New, Reroof (Tear -Off) or Recover B Mech. Attached Base Insulation, Bonded Top Insulation, Bonded Roof Cover 22 SD CWF New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 22 5E CWF New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 22 6A Gypsum New or Reroof (Tear -Off) A-1 Bonded Insulation, Bonded Roof Cover 23 6B Gypsum New, Reroof (Tear -Off) or Recover A-2 -Mech. Attached Anchor Sheet, Bonded Insulation, Bonded Roof Cover 24 6C Gypsum New, Reroof (Tear -Off) or Recover C Mech. Attached Insulation, Bonded Roof Cover 24 6D Gypsum New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet, Bonded Roof Cover 24 7A Various Recover A-1 Bonded Insulation, Bonded Roof Cover 25-26 78 Various Recover F Non -Insulated, Bonded Base Sheet, Bonded Roof Cover 26 The following notes following notes apply the systems outlined herein: systems outlined herein: 1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. 2. Insulation / base sheet fasteners shall be of sufficient length for the following deck engagement: ➢ Wood: Minimum 0.75-Inch penetration. D Steel: Minimum 0.75-Inch penetr_tion and engage the top flute of the steel deck. D Structural concrete: Minimum 1-inch embedment Into pilot hole in accordance with fastener manufacturer's published Installation Instructions. 3. unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite, gypsum -based roof board or mineral -woo[ roof hoard that meets the CIA requirements of F.A.C. Rule 61G20-3 and is documented as meeting FBC 1505.1 and, forfoam plastic, FBC Chapter 26, when Installed with the roof cover. I Exterior Research and Design, LLC. d/b/a Triniry] ERD Evaluation Report A42970.19.12-112 for F1.36027-112 Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 1 of 26 ,,jTRINITYI ERD Minimum 200 psi, minimum 2-Inch thick lightweight Insulating concrete may be substituted for rigid insulation board for System Type D (mechanically attached base sheet, bonded roof cover), whereby the base sheet fasteners are Installed through the LWIC to engage the structural steel or concrete deck. The structural deck shall be of equal or greater configuration to the steel and concrete deck listings. Roof decks and structural members shall be In accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation. S. Preliminary insulation attachment for System Type D: Unless otherwise noted, refer to Section 2.2.10.1.3 of FM Loss Prevention Data Sheet 1-29 (January 2016). Unless otherwise noted, insulation adhesive application rates are as follows. Ribbon or bead width Is at the time of application; the ribbons/beads shall expand as noted in the manufacturer's published Instructions. D HA (HA): Full coverage at 25-30 Ibs/square. D Dow INSTA STIK Quik Set Insulation Adhesive (D-IS): Continuous 0.75 to 1-inch wide ribbons, 12-Inch o.c. D Millennium One Step Foamable Adhesive (M-OSFA): Continuous 0.25 to 0.5-inch wide ribbons, 12-Inch o.c. D OMG OlyBond 500 (08500): Continuous 0.75 to 1-Inch wide ribbons, 12-Inch o.c. (PaceCart or SpotShot). Note: OlyBond Green may be used where OlyBond 500 is referenced. D OlyBond Classic (OB Classic): Full coverage at 1 gal/square. D ICP Adhesive & Sealants CR-20: Continuous 2.5-3.5-Inch wide ribbons, 12-inch o.c. D Note: When multiple loyers(s) of insulation and/or coverboard are installed in ribbon -applied adhesive, adhesive ribbons shall be staggered from layer -to -layer a distance ofone-holf the ribbon spacing. D Note: The maximum edge distance from the adhesive ribbon to the edge of the Insulation board shall be not less than one-half the specified ribbons spacing. Unless otherwise noted, all insulations are flat stock or taper board of the minimum thickness noted. Tapered polyisocyanurate at the following thickness limitations maybe substituted with the following Maximum Design Pressure (MDP) limitations. In no case shall these values be used to 'increase' the MOP listings in the tables; rather if MDP listing below meets or exceeds that listed for a particular system in the tables, then the thinner board listed below may be used as a drop -in for the equivalent thicker material listed In the table: ➢ Millennium One Step Foamable Adhesive(M-OSFA): MDP -157.5 psf (Min. 0.5-inch thick) D OMG 0lyBond 500(08500): MDP -45.0 psf (Min. 0.5-inch thick Multi -Max FA-3) ➢ OMG 0IyBond 500(08500): MDP -187.5 psf (Min. 0.5-inch thick ISO 95+GL) D OMG 0lyBond 500(OB500): MDP -315.0 psf (Min. 0.5-inch thick ENRGY 3) D OMG 0lyBond 500(OB500): MDP -487.5 psf (Min. 0.5-inch thick ACFoam Il) D ICP Adhesive & Sealants CR-20: MDP -117.5 psf (Min. 1.0-inch thick) 8. Bonded polyisocyanurate insulation boards shall be maximum 4 x 4 ft. 9. For mechanically attached components or partially bonded Insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDl, FM Loss Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk• carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 10. For fully bonded assemblies, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no rational analysis is permitted. 11. For mechanically attached components over existing decks, fasteners shall be tested In the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Standard TAS 105. 12. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing roof system (for recover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124. 13. For Recover Applications using System Type D, the Insulation is optional; however, the exiting roof system shall be suitable for a recover application. 14. Lightweight Insulating Concrete (LWC) shall be cast In accordance with FBC Section 1917 to the satisfaction of the Authority Having Jurisdiction. For systems where specific LWC is referenced, refer to current LWC Product Approval for specific deck construction and limitations. For systems where specific LWC is not referenced, the minimum design mix shall be 300 psi. In all cases, the minimum top -coat thickness is 2-inches. For LWC over structural concrete, reference is made to FBC Section 1917.4.1, Point 1. Exterior Research and Design, LLC. d/b/a Trinity H ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization 09503 a"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) S16-1485 Appendix 1, Page 2 of 26 qTFUNITYIERD 15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications. ,-- -- j(' c J TROOF COVERS. 'E i�. ' "S 'Y•."�. c_.� Reference Layer Material Application BP -AA Base Ply FBC Approved ASTM D4601, Type II HA at 20-40 Ihs/square Ply FBC Approved ASTM D2178, Type IV or VI (Base and Ply sheets, Asphalt -Applied) SBS-AA Cap Ply TriBuilt SBS Granular HA at 20-40 lbs/square (SBS, Asphalt -Applied) SBS-TA Cap Ply TriBuilt SBS Granular Torch -Applied (SBS, Torch -Applied) SBS-SA Base Ply TriBuilt SA SBS Base Self -Adhering (SBS, Self -Adhering) Cap Ply TriBUllt SA SBS Cap APP-TA Base Ply or Ply TrIBUIlt APP Smooth Torch -Applied I Cap Ply TriBuIlt APP Smooth, TriBulIt APP Granular (APP, Torch -Applied) APP-SA Cap Ply TrieuiIt SA APP Cap Self -Adhering (APP, Self -Adhering) 16. Vapor barrier options for use over structural concrete deck followed by adhered Insulation carry the following Maximum Design Pressure (MDP) limitations. The lesser of the MDP listings below vs. those in Table 3A applies' VAPORBARRICR oPT_IONsI STRUCTURAL CONCRETE DECK; ADHERED INSULATION PER TABLE 3A`- Option Primer Vapor Barrier Insulation Adhesive MDP (psf) type Attach VB-1. ASTM D41 TrIBUIIt SASBS Base Self -Adhering Inta-Stik or CR-20, 12-inch o.c. -60.0 VB-2. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Insta-Stik, 12-Inch o.c. -75.0 VB-3. ASTM D41 TriBuilt SA SBS Cap Self -Adhering Millennium One Step Foamable Adhesive, 12-Inch o.c. -157.5 VB-4. ASTM D41 ThBullt SA SBS Cap Self -Adhering CR-20, 12-inch o.c. -270.0 VB-5. ASTM D41 TrlBuilt SA SBS Base Self -Adhering Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Grade Adhesive, OlyBond 500 or CR-20, 12-inch o.c. -290.0 17. Dens Deck shall he field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements. 18. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads. Exterior Research and Design, I.I.C. d/b/a Trinity IERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization 89503 6T" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 3 of 26 TRINITY j ERD , lA>l: WOOD DECKS—piEW CONSTRUCTION oR REROOF(TEAR=OFF) ,. ,.,i, ,TABLE :,. .. .. . , .. '-SYSTEM TYPEA �AI�J�HOR SHEETiBCINDEDiNSULATION�BONDE6ROOFCOVER •� rl-" »'' 2:,MECHANICALLY-rATiACRED System Deck Anchor Sheet Base Insulation Top Insulation Reef Cover (Note 15) MOP No. (Note 1) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 0.25-inch Dens B-inch o.c. in 4- Deck, Dens Deck Prime, Polyglass G2 Base, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC SECUROCK Gypsum - Min. 19/32- CertainTeed Glasbase, Inch diameter Inch o.c. in Approved, Fiber Roof Board, Min. (Optional) SBS-AA, W 1 Inch plywood Firestone MB Base, JM tin caps with 31 three, equally ASTM C3289, HA o HA BP -AA BP AA , -60.0 at max. 24- Perma-Ply 28, Tamko ga. annular ring spaced, type II polyiso- min. (homogeneous) or min. (homogeneous) eous) APP-T APP-TA Inch spans Glass Base or shank nails staggered ganurate Inch Stry GAFGLAS #75 center rows Fiberboard High Density Fiberboard High Roof Insulation 8-Inch o.c. in 4- Polyglass G2 Base, 32 ga., 1-5/8- inch lap and 8- (Optional) FBC Min., inch Dens (Optional) SBS-SA, Min.19/32- CertainTeed Glasbase, Inch diameter Inch o.c. in Approved, Den Prime, Deck, Dens One or W 2 Inch plywood Firestone MB Base, JM tin caps with 11 three, equally ASTM C7289, HA SECUROCK Gypsum- Gypecksum- HA SBS-SA more SBS- SBS-TA, SBS-7A or -60.0 at max. 24- Perma-Ply 28, Tamko ga. annular ring spaced, type II polyiso- Fiber Roof Board or APP-TA Inch spans Glass Base or shank nails staggered cyanurate APP GAFGLAS#75 center rows 6-Inch o.c. in 4- Min. 2-Inch D-15, OB500, Min. 32 ga., 1-5/8- Inch lap and 6- ACFoam 11, III, CR-20 or M- Min. 0.25-Inch Dens D-15, SBS-AA, inch plywood plywood Polyglass Elastobase Inch diameter inch o.c. in H-Shield, H- OSFA, atop Deck, Dens Deck Prime OB500, BP -AA (Optional) SBS-TA -60.0• W-3 a[ max. 24- or Polyglass tin caps with 12 four, equally Shield CG, fastener or SECUROCK Gypsum- CR-20 or BP -AA APP TA Inch spans Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-Inch Fiber Roof Board M-OSFA shank nails staggered or ENRGY-3 oc center rows 32 ga., 1-5/8- 6-inch o.c. in 4- inch lap and 6- Min. 2-Inch D-IS, OB500, (Optional) Min. 19/32- Polyglass Elastobase inch diameter inch o.c. in ACFoam II, III, H-Shield, H- CR-20 or M- OSFA, atop (Optional) Additional D-IS, OB500, One or SBS-SA, APP SA, W-q inch plywood or Polyglass tin caps with 12 four, equally Shield CG, fastener layers of base insulation CR-20 or SBS-SA more SBS- SBS-TA or -60.0• at max. 24- Elastobase Poly ga. annular ring spaced, Multi -Max FA3 rows, 7-Inch - M-OSFA SA or APP-TA Inch spans shank nails staggered or ENRGY-3 oc APP TA center rows Exterior Research and Design, LLC. d/b/a Trinity(ERD Certificate of Authorization #9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 . Revision 2: 09/25/2017 Appendix 1, Page 4 of 26 \�TRINITYIERD I ?; -I�TA'BLE--2:.VD9RdE RECOVER 3 , SYSTEV2: VIE6HAALLYATTACHDANCHORSHEET, BONDED INSULATION, BONDED ROOF"CcV E " System Deck AnchorSheet Baseinsulation Top Insulation Roof Cover (Note 15) MOP No. (Note 1) Type Fasteners Attach Type — Attach Type Attach— Base Ply Ply Cap Ply (Psf) Min. 0.25-Inch Dens Deck, Polyglass 12-inch o.c. in 4- (Optional) FBC Dens Deck Prime, SECUROCK Min. 19/32- Elastobase or OMG Flat Inch lap and 12- Approved, Gypsum -Fiber Roof Board, (Optional) SBS-AA, SBS- W-5 Inch plywood Polyglass Bottom Plates Inch o.c. in two, ASTM C1289, HA Min. 0.75-Inch FescoBoard HA BP -AA BP AA TA, APP-TA -60.0 at max. 24- Elastobase (square) with equally spaced type 11 polylso- (homogeneous) or min. 0.5- F Inch spans Poly Roofgrip #12 staggered center cyanurate inch Structodek High Density rows Fiberboard Roof Insulation Polyglass 12-inch o.c. in 4- (Optional) FBC (Optional) Min. 19/32- Elastobase or OMG Flat Inch lap and 12- Approved, Min. 0,25-Inch Dens Deck, One or SBS-SA, APP- W-6 inch plywood Polyglass Bottom Plates Inch o.c. in two, ASTM C1289, HA Dens Deck Prime, SECUROCK HA SBS-SA more SBS- SA, SBS-TA -60.0 at max. 24- Elastobase (square) with equally spaced, type 11 polyiso- Gypsum -Fiber Roof Board SA or APP- or APP-TA inch spans Poly Roofgrip N12 staggered center cyanurate TA rows TABLE 1131: WOOD DECKS" NEW CONSTRUCTION;,REROOF:(TEAR,'OFF) OR RECOVER SYSTEM TYPE B: MECHANICALLY ATTACHED BASE INSULATION;,BONDED TOP INSULATION, BONDED ROOF COVER System Base Insulation Layer Top insulation Layer Roof cover (Note 15) MOP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psf) min. 0.75-Inch FescoBoard (Optional If (Optional if using Min. 19/32-inch Min. 1.5-Inch Dekfast Hex with 1 per (homogeneous) or min. 0.5-Inch HA using AA Ply) AA Base) one or SBSiAA, SBS-TA, -60.0 W-7 plywood at max. 24-inch ENRGY 3, H-Shield Dekfast #12 or TruFast 1.33 ft 2 Structodek High Density Fiberboard more BP -AA or APP-TA spans or Polytherm MP-3 with Roof Insulation BP AA APP-TA Exterior Research and Design, U.C. d/b/a Trinity I ERD Certificate of Authorization #9503 6r"EDITION (2017) FBC NON-HVHZ EVALUATION Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970. 1 10.12-112 for FL16027-RZ Revision 2: 09/25/2017 Appendix 1, Page 5 of 26 "T'INITYIERD TABLE 10 W00D DECKS NEW CONSTRU,CTION,REROOF(TEnR0F01 RECOVER , SYSTEMT'P_EC:MECHANICALLYAl7ACHE0INSULATION, BONDEDROOFCOVER = + ` - Base Insulation Top4nsulation Layer Roof Cover (Note 15) MOP System Deck (Note 1) Layer Type Fasteners Attach Base Ply Ply Cap Ply (psf) No. (Optional) MIn.0.5-Inch Structodek High Density Dekfast Galvalume (Optional if (Optional if using AA SBS-AA, SBS-TA,APP- Min.19/32-Inch One or more layers, Fiberboard Roof Insulation or min. 0.25- 1 per 1.33 using AA PI Base One or more BP -AA TA -82.5 W-B plywood at max. y Steel Hex with Rx g YI ) 24-inch spans anycombination, Inch Dens Deck, Dens Deck Prime or Dekfast #12 DP BP -AA or APP-TA loose laid SECUROCK Gypsum -Fiber Roof Board Dekfast Galvalume (Optional) Steel Hex with Min. 19/32-inch One or more layers, Min. 1.5-Inch ENRGY 3, H-Shield or 1 per 1.33 (Optional) One or more SBS-SA, APP-SA, SBS- 82 5 W-9 plywood at max. y Dekfast #12 DP or it, SBS-SA SBS-SA or APP-TA TAor APP-TA 2lywoo at pans any combination, Polythenn TruFast MP-3 with loose laid TruFast DP TABLE-1D: WOOD DECKS NEW CONSTRUCTION, FIEROOF (TEM OFF) oli RECOVER ' ' ATTACHED INSULATION, MECHANICALLY ATTACHEDBASE SHEET, BONDED ROOF COVER SYSTEM TYPED : PRELIMINARILY Base Sheet Roof Cover (Note 15) MOP System Deck (Note 1) Insulation Layer(s) Attach Base Fasteners Attach Base Ply Cap Ply (psf) No. Type Polyglass Elastobase, Polyglass G2 Base, OMG Flat Bottom Plates (square) with Roofgrip 12-inch o.c. In 4-Inch lap and 12- (Optional) One SBS-AA, Min. 19/32-inch One or more layers, Prelim. Elastobase Poly, Polyglass CertainTeed Glasbase, Firestone MB #14, Dekfast Hex with inch o.c. in two, equally spaced, or more BP -AA SBS-TA, -52.5 W-30 plywood at max. any combination Attached Base,JM Perma-Ply 28, Tamko Glass Dekfast 914 or TruFast staggered center rows or APP-TA -TA 24-inch spans Base or GAFGLAS #75 MP-3 with TruFast HD Dekfast Hex with Dekfast 12-inch o.C. in 4-inch lap and 12- One or more SBS-SA, APP-SA, Min. 19/32-Inch One or more layers, Prelim. Polyglass Elastobase or Polyglass #14 or TruFast MP-3 with Inch o.c. in two, equally spaced, SBS-SA or -52.5` W-11 plywood at Max. any combination Attached Elastobase Poly with poly tap surface TruFast HD staggered rows APP.T APP-7A 24-Inch spans One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-inch o.c. in 4-Inch lap and 12- inch o.c. in two, equally spaced, (Optional) One or more BP -AA SBS-AA, SBS-TA, -60.0 Min . 19/32-Inch W-12 plywood at Max. any combination Attached Elastobase Poly (square) with Roofgrip #12 staggered center rows or APP-TA APP-TA 24-inch spans SBS-SA, Min. 19/32-Inch One or more layers, Prelim. Polyglass Elastobase or Polyglass OMG Flat Bottom Plates 12-Inch o.c. in 4-inch lap and 12- Inch o.c. in two, equally spaced, One or more SBS-SA APP-SA, SBS-TA -60.0 ` W-13 plywood at max. any combination Attached Elastobase Poly with poly tap surface (square) with Roofgrip #12 staggered center rows APP-TA 24-Inch spans Evaluation Report A42970.10.12-R2 for FL16027-R2 Exterior Research and Design, I.I.C. d/b/a Trinity H ERD CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Certificate of Authorization #9503 Appendix 1, Page 6 of 26 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Root Systems; (800) 516-1485 (TTRINITY ERD TABLE H-4"Willop REc0"NEwc9,Ns;TRUcrION OR REROOIF (TW-OFF) ATTACHED D' BASE SON 0 E D 00 R ANON ZSULATtDj'IVItCHANICAL1LY ROOF COVER'- SYSTEIVITYPE -INSULATED; System Base Sheet Roof Cover (Note 15) MOP MOP No. No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Pso Min. 15/32-inch 9-Inch o.c. at 2-inch lap and 18-inch o.c. In two, (Optional) BP -AA or SBS-AA, SBS-TA W-14 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap equally spaced, staggered center rows APP-TA orAPP-TA spans Min. 15/32-inch 9-Inch o.c. at 2-Inch lap and 12-inch o.c. In two, (Optional) BP -AA or SBS-AA, SBS-TA W-15 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap equally spaced, staggered center rows APP-TA or APP-TA 5 -52.5 Inch spans Min' 19/32-Inch Polyglass Elastobase, Polyglass Elastobase (Optional) One or Poly, Polyglass G2 Base, CertaInTeed 32 ga., 1-5/8-inch diameter tin ups 9-inch o.c. In 4-Inch lap and 8-inch o.c. In three, BP SBS-AA, 585- W-16 plywood at max. Glasbase Firestone MB Base, JM Forma- with 11 ga. annular ring shank nails equally spaced, staggered center rows more -AA or APP-TA TA, APP-TA -60.0 24-Inch spans Ply 28, ;�mko Glass Base or GAFGLAS #75 n. 19/32-Inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 8-Inch o.c. in 4-inch lap and 8-inch o.c. In three, (Optional) One or SBS-SA, APP- ood at max- Elastobase Poly with poly top surface with 11 ga. annular ring shank nails equally spaced, staggered center rows more SBS-SA or SA, SBS-TA or r6o.0 4-inch spans APP-TA APP-TA Min. 15/32-inch 6-Inch o.c. at 2-inch lap and 6-inch o.c. In two, (Optional) BP -AA or SBS-AA, SBS-TA W-18 plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap equally spaced, staggered center rows APP-TA orAPP-TA -90.0 Inch spans Min.19/32-Inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-inch diameter tin caps 4-inch o.c. in 4-Inch lap and 4h o.c. In four, (Optional) One or SBS-SA, APP- W-19 Plywood at max. Elastobase Poly with poly top surface with 11 ga. annular ring shank nails. equally spaced, staggered center rows more SBS-SA or SA, SBS-TA or -97.5 24-inch spans APP-TA APP-TA W-20 Min. 15/32-inch plywood at max. 24- Polyglass Elastobase Simplex MAXX Cap 6-inch o.c. at 2-inch lap and 6-Inch o.c. in three, (Optional) BP -AA or SBS-AA, SBS-TA -105.0 equally spaced, staggered center rows APP-TA orAPP-TA inch spans — Min. 19/32-Inch Polyglass Elastobase or Polyglass 32 ga., 1-5/8-Inch diameter tin caps 6-inch o.c. in 4-inch lap and 6-Inch o.c. In four, (Optional) One or I SBS-AA, SBS W-21 plywood at max. Elastobase Poly with 11 ga. annular ring shank nails equally spaced, staggered center rows more BP -AA or TA, APP-TA -112.5 24-inch spans APP-TA I — Min. 19/32-Inch 32 go., 1-5/8-Inch diameter tin caps SB I S-SA, APP- Polyglass Elastobase or Polyglass with 11 ga. annular ring shank nails. 6-inch o.c. in 4-Inch lap and 6-inch o.c. In four, (Optional) One or SA, SBS-TA or -112.5 W-22 plywoo at max. Elastobase Poly with poly top surface Note: Tin caps are to be primed with equally spaced, staggered center rows more APP-TA APP-TA 24-inch pans I ASTM D41 primer. I I I I Exterior Research and Design, U.C. d/b/a Trinity I ERD Certificate of Authorization #9503 67 EDITION (2017) FBC NON-HVHZ EVALUATION Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 I Evaluation Report A42970.1 ' D.12-R2 for FL16027-R2 Revision 2: 09/25/2017 Appendix 1, Page 7 of 26 \\,\,ITR INITY I ERD - r,a 1� TABLE lEZ WOODpEd NEWCO071`97014,REROOF,(Tena OFFJ Op REtovDt „y,_ ' t"rr ,( � ' (' �iEEi,BONUEpR00F,COVEg-,, n ,ICALLYATTACHED.BASE - ,wSYSTEM'jYP,E E;,NON INSULATED, MECHAN System Base Sheet Roof Cover (Note 1S) MDP No. Deck (Note 1) Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 19/32-Inch Polyglass Elastobase, Polyglass Elastobase OMG Flat Bottom Plates (square) with 12-Inch o.c. in 4-inch lap and 12-Inch (Optional) One or SBS-AA, SBS- W-1 plywood at max.. Paly, Polyglass 62 Base, CertainTeed Roofgrip #14, Dekfas[ Hex with Dekfas[ #14 two, equally spaced, staggered more BP -AA or TA APP TA -52.5 24-inch spans Glasbase, Firestone MB Base, JM Perma- orTruFast MP-3 with 7ruFast HD center r rows APP-TA Ply 28, Tamko Glass Base or GAFGLAS#75 Min. 19/32-Inch Polyglass Elastobase or Polyglass Dekfast Hex with Dekfast 414 or TruFast MP- 12-inch o.c. in 4-inch lap and 12-Inch o.c. In two, equally spaced, staggered One or more SBS- SBS-SA, APP- SA, SBS-TA or -52.5- W-2 plywood at max. Elastobase Poly with poly top surface 3 with TruFast HD rows SA APP-TA 24-inch spans center Min'19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-Inch o.c. in 4-Inch lap and 12-Inch o.c. in two, equally spaced, staggered (Optional) One or more BP -AA or SBS-AA, SBS- -60.0 W-3 plywood at max. Elastobase Poly Roofgrip#12 rows APP-TA TA, APP-TA 24-inch spans center Min. 19/32-inch Polyglass Elastobase or Polyglass OMG Flat Bottom Plates (square) with 12-Inch o.c. in 4-Inch lap and 12-inch o.c, in two, equally spaced, staggered One or more SBS- SBS-SA, APP- SA, SBS-TA or -60.0• W-4 plywood at max. Elastobase Poly with poly top surface Roofgrip #12 center rows SA APP-TA 24-inch spans TABLE IF WOODDECKS—NEW CONSTRUCTIONORREROOF(TEAT OFp) - " - `'• -.. SYSTEM.TYP.E F:NON-INSULATED BONDEDROOFCOVER - `ryr - - , -a-,. t r ,== Roof cover (Note15) MDP System Deck Primer (Psf) Joint Treatment Ply Ply i Ply Cap in_15/ -inch plywood None tB3i5A BS=SA.or .SBSSA„APPA 85�5- A� -90'0 axrh p- Min. 15/32-inch plywood (Optional ASTMD41 Plywood Joints are covered with 4-Inch wide strips of TdBuilt SA &1ptionap TriBullt SA SBS Base APP, TA (Optional)SBS-SA or 6o_r�APP-TAt_ 4:_ SBS-SA, APP-SA, SBS-TA -6 at max. 24-inch spans (Optional) ASTM D41 SBS Base, rolled Into place to create continuous bond. APP TA or APP-TA I ;97.5 Exterior Research and Design, U.C. d/b/a Trinity) ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 C" EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for 1L36027-112 Revision 2: 09/25/2017 Appendix 1, Page 8 of 26 RINITY I ERD .TABLE 2A STEEL OR STRUCTURALCONCRETE DECKS—NEW.CONSTRUCf10N, REROOF(TFAa OFF)OR RECOVER .. . . . .h . .. -. -..-, .,., - " : SYSTEM TYPE B: MECHANICALLYATTACHED BASE INSULATION, BONDEDTOP INSULATION, BONDED ROOFCOVER E., y „ , System peck (Note 1) Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) Nlpp No. Type Fasteners Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 22 ga., type B, Min. Inch Dekfast Hex with Trufast Dekfa5tMP-3 MIn. 0.75-inch FescoBoard (Optional if using SC-1. Grade 33 steel or am ACFoam II, ENRGY w tth T MP-3 with Trufast HD or 1 per 2 it' (homogeneous) or min. 0.5-inch HA (Optional If using AA Base) One or SBS-AA, SBS- -45.0• min. 2,500 psi 3, H-Shield or OMG 3-Inch Plate Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm with OMD HDD Fiberboard Roof Insulation APP-TA Min. 22 ga., type e, Min. 2-inch Dekfast Hex with Dekfast R14, Trufast Min. 0.75-inch FescoBoard (Optional if using SC-2. Grade 33 steel or ACFoam II, ENRGY MP-3 with Trufast HD or 1 per 4 ft' (homogeneous) or min. OS -inch HA (Optional if using AA Base) One or SBS-AA, SBS- -q5.0" min. 2,500 psi 3, H-Shield or OMG 3-inch Galy Plate Structodek High Density AA Ply) BP -AA more BP -AA or TA, APP-TA structrual concrete Polytherm with OMD HD Fiberboard Roof Insulation APP-TA Min. 22 ga., type B, Min. 1.5-Inch Dekfast Hex with Min. 0.75-Inch FescoBoard (Optional if using SC-3. Grade 33 steel or ENRGY 3, H-Shield Dekfast 414 or TruFast 1 per 1.33 (homogeneous) or min.0.5-inch HA (Optional if using AA Base) One or SBS-AA, SBS- min. psi or Polytherm MP-3 with TruFast HD z it, High Density AA Ply) BP -AA more BP -AA or TA, APP-TA -90.0 structrual structrual concrete FiberStrucboarddek Fiberboard Roof Insulation APP-TA Min. 22 ga., type B, Grade 33 steel or Min. 1.5-inch Dekfast Hex with 1 per 1.33 Min. 0.75-inch FescoBoard (homogeneous) or min. 0.5-inch BP-AA(Top surface One or more SBS-SA,APP- SC-4. min. 2,500 psi ENRGY 3, H-Shield tth ft x Structodek High Density HA primed with ASTM layers, SBS-SA or SA, SBST A -90.0 structrual concrete or Polytherm MP-3 wDekfast MP-3 with TruFast HD astTruHD[ Tru14 Fast Fiberboard Roof Insulation D41 primer) APP-TA or APP-TA TABLE 213:STEEL,ORSTRUCTURAL CONCRETE DECKS —NEW CONSTRUCTION, REROOF(TrAROFF) ORRECOVER 2 f SYSTEM TYPEC: MECHANICALLY ATTACHED. INSULATION,BONDED ROOF.COVER System Deck (Note 1) Base Insulation Top Insulation Layer Roof Cover (Note 15) MOP Type Fasteners Attach Base Ply Ply Cap Ply No. Layer (Psf) Min. 22 ga., type B, (Optional) One or (Optional if (Optional if using AA Grade 33 steel or more layers, any Min. Inch SECUROCK Gypsum- OMG 3-Inch Galvalume Steel 1 per 1.78 SBS-AA, SBS- SC-5. min. 2,500 psi combination, loose Ro Fiber Roof Board Plate with OMG d14 HD ftz using AA Ply) Base) One or more BP- TA APP TA -75.0 structrual concrete laid BP -AA AA or APP-TA Min. 0.5-Inch Structodek High Min. 22 ga., type B, One or more layers, Density Fiberboard Roof Dekfast Galvalume Steel Hex with (Optional if (Optional if using AA SC-6. Grade 33 steel or any combination, Insulation ormin. 0.25-Inch Dens Dekfast (steel only) or k14 or 1 per 1.33 z using AA Ply) Base) One or more BP- SBS-AASBS- , -82.5 min. 2,500 psi loose laid Deck, Dens Deck Prime or TruFast MP-3 with TruFast DP it BP -AA AA or APP-TA 7A, APP-TA structrual concrete SECUROCK Gypsum -Fiber Roof (steel only) or HD Board Min. 22 ga., type B, (Optional) Dekfast Galvalume Steel Hex with SBS-AA,SBS- Grade 33 steel or One or more layers, Min.1.5-inch ENRGY 3, H-Shield Dekfast#12 (steel only) or k14 or i per 1'33 (Optional) One or more TA, SBS-SA, SC-7. min. 2,500 psi any combination, or Polytherm TruFast MP-3 with Trufast DP W SBS-SA SBS-SA or APP-TA APP-TA, APP- -82.5 structrual concrete loose laid (steel only) or HD SA Exterior Research and Design, LLC. d/b/a TrinityI ER Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization $19503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 9 of 26 J J TRINITY I ERD - TABLE 2C-STEEL OR STRUCfURAI CONCRETE DECILS NEW CONSTRUCTION, REROOF(TFAR OFE)aR RECOVER _ , M SYSTETYPED PRELIMINARILY ATTACHED INSULATION MECHANICALLY ATTACHED BASE SHEET BONDED ROD P COVER - -'NOTE: INSULATION IS FOR RECOVER OPTIONAL APPLI&TIONS>= - r-,-- System Deck Insulation Layer(s) Base Sheet Roof Cover INote 15) MDP No. (Note 1) Type Attach Base Fasteners Attach Base Ply Cap Ply (Psf) Min. 22 ga., type B, One more Polyglass Elastobase, Polyglass OMG Flat Bottom Plates (square) 12-inch ox. in 4-inch lap (Optional) One or SC-8. Grade 33 steel or min. s, a Prelim. Elastobase Poly orJM Perma- with Roofgrip d14, Dekfas[ Hex and 18-inch o.c. in two, more BP -AA or APP- SBS-AA, SBS- -45.0' 2,500 psi structrual combination combinattion Attached Ply 28 with Dekfast #14 or TruFast MP-3 equally spaced, staggered TA TA, APP-TA concrete with TruFast HD center rows Polyglass Elastobase, Polyglass Min. 22 ga., type B, Elastobase Poly, Polyglass G2 OMG Flat Bottom Plates (square) 12-inch o.c. in 4-inch lap Grade 33 steel or min. One or more Prelim. Base, CertainTeed Glasbase, with Roofgrip # 14, Dekfast Hex and 12-Inch stag in two, (Optional) One or SBS-AA, SBS- SC-9. 2,500 psi structrual layers, any Attached Firestone MB Base, JM Perma- with Dekfast #14 or Trufast MP-3 equally spaced, staggered more BP -AA or APP- 7A, APP-TA -52.5 concrete combination Ply 28, Tamko Glass Base or with TruFast HD center rows TA GAFGLAS #75 Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-Inch o.c. in 4-Inch lap SBS-SA, APP- SC-10. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #14, Dekfast Hex and 12-Inch stag in two, One or more SBS-SA SA, SBS-TA -52.5' psi structrual combination Attached poly top surface with Dekfast #14 or TruFast MP-3 equally spaced, staggered or APP-TA concrete concr with TruFast HD center rows Min. 22 ga., type B, Ones, more OMG Flat Bottom Plates (square) 12-Inch O.C.in 4-inch lap nap One or SC-11. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase or with Roofgrip #12 (steel only) or and 12-Inch stag in two, more more BP -AA or APP- SBS-AA, 585- -60.0 2,500 psi structrual combination Attached Polyglass Elastobase Poly #14 equally spaced, staggered TA TA, APP-TA concrete center rows Min. 22 ga., type B, One or more Polyglass Elastobase or OMG Flat Bottom Plates (square) 12-Inch o.c. in 4-Inch lap SBS-SA, APP- SC-12. Grade 33 steel or min. layers, any Prelim. Polyglass Elastobase Poly with with Roofgrip #12 (steel only) or and 12-Inch stag in two, One or more SBS-SA SA, SBS-TA -60.0' psi structrual combination Attached poly top surface 414 equally spaced, staggered or APP-TA concrete concrete center rows Min. 22 ga., type B, One or more Grade 80 steel or min. Prelim. Dekfast isofast IF-2.375-AT Plates 12-Inch o.c. in the 5-inch SBS-TA, APP- SC-13. 2,500 psi structrual layers, any Attached TriBuilt APP Smooth with Dekfast #15 HS wide, heat -welded side lap (Optional) APP-TA TA -82.5 combination concrete Min. 22 ga., type B, One or more Grade 80 steel or min. Prelim. Trufast 2.4 in. Barbed Seam 12-Inch o.c. in the 6-inch 5B5-TA, APP- SC-14. 2,500 psi structrual layers, any Attached TriBuilt APP Smooth Plates with Trufast EHD Fasteners wide, heat -welded side lap (Optional) APP-TA TA -82.5 combination concrete Min. 22 ga., type B, One or more Dekfast Hex with Dekfast #14 or 12-Inch o.c. in the 4-Inch SC-15. Grade 33 steel min. layers, any Prelim. TriBuilt APP Smooth OMG Flat "_ottom Plates with lap and 18-inch stag in two, (Optional) BP -AA or 585-AA, SB$- -112.5 ru psi structrual combination httached OMG Roofgrip #14 equally spaced, staggered APP-TA 7A, APP-TA concrete concrete center rows Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 10 of 26 TRINITY I ERD TABLE3A:StR, CgURALCONCRETEDECKS NEW CONSTRUCTIONJ OR REROOF(TFAROFF) _' -,SYSTEMTYPEAr BON-dEDINSULATI,ON,BONDEU'ROOF COVER SEE NOTE I@FOR VAPOR BARI(IER System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Primer Type Attach Type Attach Base Ply Ply Cap Ply (psf) SEE ADNEWNGSYST[MSWrm'BMEINSUlATIONANDOPEIONALTOPINSUMVONOFTNESAMETYPE- t- Structural (Optional) Min.1.5-Inch H-Shield or Multi -Max (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C 1 concrete ASTM D41 FA3 D-IS base insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -67.5 Structural (Optional) (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, L 2 concrete ASTM D41 in. 1.5-Inch ACFoam II or ENRGY 3 D-IS base Insulation D-IS SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -135.0 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C-3 None Min. 1.5-Inch, min. l.S pcf lnsulfoam DAS DAS SBS-SA -157.5 concrete insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C4 None MIn.1.5-inch, min. 2.0 pcf lnsulfoam OB500 OB500 SBS-SA -120.0 concrete Insulation SBS-SA or APP-TA SBS-TA or APP-TA Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-5 concrete None Min. 1.5-inch ENRGY3 OB500 base insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -127.5 Structural (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-6 concrete None Min. 1.5-Inch ACFoam ll or H-Shield OB500 base insulation OB500 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -150.0 Structural Min. 1.5-Inch ACFoam 11, ENRGY 3, H- (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-7 concrete None Shield or Multi -Max FA3 M-OSFA base insulation M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -232.5 Structural (Optional) additional layers of base (Optional) One or more SBS-SA, APP-SA, C B concrete None Min. 1.5-inch, min. 2.0 pcf lnsulfoam CR-20 Insulation CR-20 SBS-SA SBS-SA or APP-TA SBS-TAor APP-TA -240.0 Structural min. 1.5-Inch ACFoam 11, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-Si , APP-SA, C-9 concrete None ENRGY 3,H-Shield, H-Shield CG, Multi- CR-20 base Insulation CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -270.0 Max FA3 or ISO 95+ GL Structural OB (Optional) additional layers(s) of OR (Optional) One or more SBS-SA, APP-SA, C-30 None Min. 2-inch ACFoam ll or H-Shield Classic base insulation Classic SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA 270.0 concrete (FULL) (FULL) Structural Min. 1.5-Inch ACFoam 11, ACFoam III, (Optional) additional layers(s) of (Optional) One or more SBS-SA, APP-SA, C-11 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA base insulation HA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -480.0 Multi -Max FA3 �SELFADRERING SYSTEMS WRIT BASE INSULATION AND COVERBOARO: Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more SBS SA, APP SA, C-12 concrete None Min.1.5-inch Multi -Max FA3 DAS Fiber Roof Board DAS 5BS-SA SBS-SA or APP-TA SBS-TA or APP-TA -67.5 Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA,APP-SA, C-13 concrete None MIn. 1.5-Inch, min. 2.0 pcf Insulfcam D-IS Deck Prime D-IS SBS-SA SBS-_A or APP-TA SBS-TA or APP-TA -120.0 Structural Min. 2-Inch ACFoam 11, ENRGY-3 or H- Min. 0.25-Inch SECUROCK Gypsum- D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA, 247.5 C-14 concrete None Shield D-IS Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Structural Min. 0.25-inch Dens Deck, Dens (Optional) One or more 5BS-SA, APP-SA, C-15 concrete None Min. 1.5-Inch ENRGY3 0B500 Deck Prime OB500 5BS-SA SBS-SA or APP-TA SBS-TA or APP-TA -127.5 Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization N9503 6EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:09/25/2017 Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 11 of 26 `r \ I TRINITY I ERD '' , '' r -- '.TABLE 3A STRUCTURAL FONCRETE DECKS -NEW fONSTRUCiION ORREROOF�TEAR OFFS i t, Lr SYSTEM TI,(PE,41: BONDEDINSULATION BONDED ROOF COVER v .. e v - oSEE NOTE 16 VAPOR BARRIER OPTIONS FOR System Primer Base Insulation layer Top Insulation Layer Roof Cover (Note 15) MDP No. Deck Type Attach Type Attach Base Ply Ply Cap Ply (Psi) Structural None Min.1.5-inch ACFoam II,H-Shieldor Min. 0.25-inch Dens Deck, Dens (Optional) One or more SBS-SA, APP-SA, C-16 Concrete 15095+GL O8500 Deck Prime OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -150.0 Structural Min. 2-Inch ACFoam 11, ENRGY-3 or H- Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C17 concrete None Shield OB500 Fiber Roof Board OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 Structural Min. 1.5-Inch ACFoam II, ENRGY 3, H- Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-18 concrete None Shield or Multi -Max FA3 M-OSFA Fiber Roof Board M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -232.5 Structural Min. 2-inch ACFoam 11, ENRGY-3 or H- Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-19 concrete None Shield M-OSFA Fiber Roof Board M-OSFA SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 C 20 Structural None Min. 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-Inch Dens Deck, Dens CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, concrete Deck Prime SBS-SA or APP-TA SBS-TA or APP-TA 240 0 Min. 1.5-Inch Ultra -Max or Multi -Max Structural FA-3, min. 1.3-inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-ZS concrete None 1.0-inch IS095+GL, H-Shield, H-Shield CR-20 Fiber Roof Board CR-20 SBS-SA SBS-SAor APP-TA SBS-TAor APP-TA -240.0 CG or ENRGY 3 Structural Min. 2-Inch ACFoam II, ENRGY-3 or H- Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C 22 concrete None Shield CR 20 Fiber Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -247.5 OB 06 Structural Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more SBS-SA, APP-SA, C-23 concrete None Min. 2-Inch ACFoam II or H-Shield Classic Fiber Roof Board Classic SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -350.0 (FULL) (FULL) Min. 1.5-Inch ACFoam 11, ACFoam III, C-24 Structural ASTM D41 ENRGY 3, H-Shield, H-ShIeId CG or HA Min. 0.25-inch SECUROCK Gypsum- HA SBS-SA (Optional) One or more SBS-SA, APP-SA, -350.0 concrete Multi -Max FA3 Fiber Roof Board SBS-SAor APP-TA SBS-TA or APP-TA ASPNALTAND/ORTORm APPDEO SYSTEMS: ... -`. ... •. .L ... x ,.,. `•` ..^ - - Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more C 25 None Min. 2-Inch ACFoam II or H-ShIeId D-IS I D IS BP AA SBS-AA -225.0 concrete Fiber Roof Board BP -AA Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more C 26 None Min. 2-Inch ACFoam It or H-ShIeId D-IS D-IS APP-TA APP-TA -232.5 concrete Fiber Roof Board APP-TA Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more C 27 None Min. 2-Inch ACFoam II or H-ShIeId OB500 OB500 BP -AA SBS-AA -225.0 concrete Fiber Roof Board BP -AA C-28 Structural None Min. 2-Inch ACFoam II or H-Shield OB500 Min. 0.25-inch SECUROCK Gypsum- OB500 APP-TA (Optional) One or more APP-TA -232.5 concrete Fiber Roof Board APP TA Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more C 29 None Min. 2-Inch ACFoam II or H-Shield M-OSFA M-OSFA BP -AA SBS-AA -225.0 concrete Fiber Roof Board 8P-AA Structural Min. 0.25-Inch SECUROCK Gypsum- (Optional) One or more C-30 None Min. 2-inch ACFoam II or H-Shield M-OSFA M-OSFA APP-TA APP TA -232.5 concrete Fiber Roof Board APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity ERD Certificate of Authorization #9503 Prepared by: Robert Nieminen, PE-59166 6r"EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 (Revision 2: 09/25/2017 Aplpendix 1, Page 12 of 26 TT�RINITYJERD STE Y - S �MTipEA:i:;B6"NDEEiiNSULAtIONiBONbEDAOOF�C6VER. a z,.SEENOTE 16FOR VAPOR RIE11,01TI0N Sj system Deck Primer Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MOP No. Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Ultra -Max or Multi -Max C-31 Structural None FA-3, min. 1.3-Inch ACFoam III or min. Min. 0.25-inch SECUROCK Gypsum- (Optional) one or more concrete 1.0-Inch ISO 95+GL, H-Shield, H-Shleld CR-20 Fiber Roof Board CR 20 BP AA BP -AA SIIS-AA -225.0 CG or ENRGY 3 Min. 1.5-inch Ultra -Max or Multi -Max C-32 Structural None FA-3, min. 1.3-inch ACFoam III or min. CR-20 Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more concrete 1.0-inch ISO 95+GL, H-Shield, H-Shield Fiber Roof Board CR-20 APP-TA APP-TA APP-TA -232.5 CG or ENRGY 3 C-33 Structural None (Optional) Min. 2-inch ACFoam 11 or H- OB classic Min. 0.25-inch SECUROCK Gypsum- OB (Optional) One or more concrete Shield Fiber Roof Board Classic BP -AA BP -AA SBS-AA -225.0 (FULL) (FULL) C-34 Structural None (Optional) Min. 2-Inch ACFoam 11 or H- OB classic Min. 0.25-Inch SECUROCK Gypsum- OR (Optional) One or more concrete Shield Fiber Roof Board Classic APP-TA APP-TA APP-TA -232.5 (FULL) (FULL) C-35 Structural ASTM D41 Min 1.5-Inch ACFoam 11, ACFoam III, ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.25-inch SECUROCK Gypsum- HA BP -AA (Optional) One or more concrete Multi -Max FA3 Fiber Roof Board BP -AA SBS-AA -225.0 Structural Min. 1.5-Inch ACFoam 11, ACFoam 111, Min. 0.25-inch SECUROCK Gypsum- (Optional) One or more C-36 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Fiber Roof Board HA APP-TA APP-TA APP-TA -232.5 Multi -Max FA3 (Optional If C-37 Structural ASTM D41 Min. 0.75-inch FescoBoard HA None N/A using AA Ply) (Optional If using AA Base) One or more BP- SBS-AA,SBS-TA, concrete (homogeneous) One or more APP-TA -277.5 BP -AA AA or APP-TA StrL rctural Min.1.5-inch ACFoam 11, ACFoam III, (Optional if (Optional if using AA C-38 concrete ASTM D41 I ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.75-inch Fesco Board HA using AA Ply) Base) One or more BP- SBS-AA, SBS-TA, -290.0 Multi -Max FA3 One or more AAorAPP-TA APP-TA BP -AA (Optional if C-39 Structural ASTM D41 Min. inch Structodek High Density HA None N/A using AA Ply) (Optional If using AA SBS-AA, SBS-TA, concrete Fiberboard Roof Insulation One or more Base) One or more BP- APP-TA -285.0 BP -AA AA or APP-TA Structural Min. 1.5-Inch ACFoam 11, ACFoam 111, Min. 0.5-inch Structodek High (Optional If using AA Ply) (Optional if using AA SBS-AA, SBS-TA, C-40 concrete ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Density F Fiberboard Roof Insulation HA One or more Base) One or more BP. APP-TA -480.0 Multi -Max FA3 AA or APP-TA I BP -AA Exterior Research and Design, UU1 d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization #9503 CH EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (sco) s16-mils Appendix 1, Page 13 of 26 �TRINITYI ERD ';tABLE3A: STRUcrURALCONCRETE DECKS- NEW, CONSTRUCTION i0iA �:;SYSTIEIVIT -1�BONDiD'IN'S�ULATION,BONDED*RobFC'OVEW" SEE NOTE 16 FORAPOR ARRIEROP'no _S System Deck Primer Base Insulation Layer — Top Insulation Layer Roof Cover (Note is) MDP No. Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Structural Min. 1.5-inch ACFoam 11, ACFoam Ill, (Optional if (Optional if using AA C-41 ASTM D41 ENRGY 3, H-Shield, H-Shield CG or HA Min. 0.25-inch Dens Deck Prime HA using AA Ply) Base) One or more BP- SBS-AA, SBS.TA, -480.0 concrete Multi -Max FA3 One or more AA or APP-TA APP-TA BP -AA C-42 Structural ASTM 041 Min. 0.25-inch Dens Deck Prime HA None N/A (Optional if using AA Ply) (Optional if using AA Base) One or more BP- SBS-AA, SOS -TA, concrete One or more APP-TA -9101 -510.0 BP -AA AA or APP-TA TABLE 36: STRUCTURAL CONCRETE DECKS- NEW CONSTRUCTION OR R I ' ' . .' -' ' ; I EROOF [TEAR-0iF)! 7 SYSTEM TYPE F; NON -INSULATED, BONDED BASE SHEET,'40NDED ROOF CCIVER-; System No. Deck Primer Roof Cover (Note 15) MDP (Psf) Base Ply Ply Cap a IV C-43 Structural concrete ASTM M BS-SA I S (Optional) SBS-SA or _S-TA or APP-TA i SBS-SA, APP-SA SBP -315.0 C-44 Structural concrete AST D41 BP -AA (Optional if using asphalt applied Ply) — (Optional if using asphalt applied Base) BP -AA or APP-TA SBS-AA, SBS-TA, APP-TA -622.5 Exterior Research and Design, U.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 09503 6"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems, (goo) si&ias Appendix 1, Page 14 of 26 J TRINITY I ERD I aTABLE4A: LIGHTWEIGHTC0NCRETEDECKS-NEWLONSTRUCI'IONDa REROOF(TFAROFF)',•.` -' >>.' SYSTEM TYPEA-I:+BONDEDINSULgTION,BONDED ROOF COVER System Oeck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 151 MOP No. (Note 1) -.. Concrete (Note 14) ... (psf) Type Attach -o Type Attach Base Ply Ply Cap Ply . _ _ ,.. .... �SEiF-AOHENNG SYSTEMS WITH BASE INSUUATIONANU:OPTIONAL TOP,INSLLAiION OFTHESAMETYPEf. ' LWC 1 Structural Min. 200 psi, min 2- Min. 1.5-inch, min. 2.0 pcf Insulfoam p OB500 (Optional) Additional OB500 SBS-SA (Optional) One or SBS-SA, APP ' concrete Inch Elastizell layers of base insulation more SBS-SA SA 120.0 LWC 2 Structural Min. 200 psi, min 2- MIn.1.5-inch ACFoam II, ENRGY 3, ISO 95+ GL (Optional) Additional (Optional) One or SBS-SA,APP- concrete inch Elastizell or H-Shield OB500 layers of base insulation OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA LWC-3 Structural Min. 200 psi, min. Min. 2.0 pcf Insulfoam CR-20 (Optional) Additional CR-20 SBS-SA (Optional) One or SBS-SA,APP- concrete 2-Inch Elastizell layers of base insulation V more SBS-SA SA -180.0 Structural Min. 200 psi, min. Min. 1.5-Inch ACFoam II, ACFoam III, ENRGY 3, (Optional) Additional (Optional) One or SBS-SA, APP- LWC-4 concrete 2-Inch Elastizell ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers of base insulation CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 FA3 APP-TA or APP-TA LWC-5 Structuml Min. 200 psi, min. 2-Inch Celcore or Min. 2.0 pcf Insulfoam CR-20 (Optional) Additional CR-20 SBS-SA (Optional) One or SBS-SA, APP- cencre[e Mearlcrete layers of base insulation more SBS-SA SA 222.5 Structural Min. 200 psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, (Optional) (Optional) One or SBS-SA, APP- LWC-6 concrete 2"inch Celcore or 150 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 layers of base insulation se insulation CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 Mearlcrete FA3 APP-TA or APP-TA . SELILADHEWNG SYSTEMS WNN BASE INSULATION AND COVERROARD::"..; LWC 7 Structural Min. 200 psi, min 2- 0.2 Min. 0.25-inch SECUROCK (Optional) One or SBS-SA,APP- concrete Inch Elastizell Min. 1.5-inch, min. 2.0 pcf Insulfoam OBSOO Gin. Fiber Roof Board OB500 SBS-SA more SBS-SA or SA, SBS-TA -120.0 APP-TA or APP-TA LWC-8 Structural Min. 200 psi, min 2- Min. 1.5-Inch ACFoam II, ENRGY 3, ISO 95+GL Min. 0.25-inch SECUROCK (Optional) One or SBS-SA, APP- concrete Inch Elastizell orH-Shleld OB500 Gypsum -Fiber Roof Board OB500 SBS-SA more SBS-SA or SA, SBS-TA -225.0 APP-TA or APP-TA Structural Min. 20D psi, min. Min. 1.5-inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-inch SECUROCK (Optional)One or SBS-SA,APP- LWC-9 concrete 2-Inch Elastizell I50 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -180.0 FA3 or min. 2.0 pcf Insulfoam APP-TA or APP-TA Structural Min. 200 psi, min. Min. 1.5-Inch ACFoam 11, ACFoam III, ENRGY 3, Min. 0.25-Inch SECUROCK (Optional) One or SBS-SA, APP- LWC-10 concrete Celcore or ISO 95+GL, CG, MuI[I-Max CR-20 Gypsum -Fiber Roof Board CR-20 SBS-SA more SBS-SA or SA, SBS-TA -222.5 Meafl Mearlcrete 2.0 pcf Insulfoam FA3 or min. 2.0 cf Insul(Gam P APP-TA or APP-TA 'ASPHAITANO/ORTOR[HAPPLIEb UD v - SYSTEMS. N, ' LWC-31 Structural Min. 200 psi, min 2- Min. 1.5-Inch ACFoam II, ENRGY 3, ISO 95+GL Min. 0.25-Inch SECUROCK BP -AA (Optional) One or SBS-AA, SBS- concrete Inch Elastizell or H-Shleld OB500 Gypsum -Fiber Roof Board OB500 APP TA re BP -AA or APP- TA APP TA -225.0 TA LWC-12 Structural Min. 200 psi, min. Min. 1.5-Inch ACFoam II, ACFoam III, ENRGY 3, Min. 0.25-Inch SECUROCK BP -AA, (Optional) One or SBS-AA,SBS- concrete 2-Inch Elastizell ISO 95+GL, H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 APP TA more BP -AA or APP- TA APP TA -180.0 FA3 or min. 2.0 pcf Insulfoam TA Exterior Research and Design, I.I.C. d/b/a T:inity)ERD Evaluation Report A42970.10.12-R2 for FL16OZ7-RZ Certificate of Authorization 09503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems, (800) 516-1485 Appendix 1, Page 15 of 26 QTRINITY 1 ERD I LI01H E10111TCONCIBETE DECKS' NEW corimucriON OR RIEROOF (TEAR IF) STEMTYPEA;U % -BONDED INSULATION, BONDED ROOF COVER System Deck Lightweight Base Insulation Layer Coverboard Roof Cover (Note 15) MD1P Type Attach Type Attach Base Ply Ply Cap Ply No. (Note 1) Concrete (Note 14) (Psf) Structural Min. 200 psi, min. Min. 1.5-inch ACFoam 11, ACFoam 111, ENRGY 3, Min. 0.25-inch SECUROCK BP -AA (Optional) One or SBS-AA, SBS- LWC-13 concrete 2-Inch Celcore or ISO 95+ GI., H-Shield, H-Shield CG, Multi -Max CR-20 Gypsum -Fiber Roof Board CR-20 I I A more BP -AA or APP. I -222.5 MearIcrete FA3 or min. 2.0 pcf In TA TA, APP-TA TABLE413:LIGHTWEIGHT CONCRETE DECKS= NEW CONSTRucrioN aft RERO IF(Teiiin -OFF)., 0 E A-2: MECHANICALLY' SYSTEM TYP ATTACHED ANCHOR SHEET, BONDED INSULATION,' BONDED R 60F COVER - :'4 System Deck Lightweight Anchor Sheet Base Insulation Top insulation Roof cover (Note 1 ) 1 Concrete MOP - No. (Note 1) (Notee.4) Type Fasteners Attach Type Attach Type Attach Base Ply Ply Cap Ply 1 (PSf) Min. 1.5-Inch Min. 22 ga., 7-Inch o.c. at (Optional) Min. Thermaroof Composite, Type B, Min. 300 psi 4-inch lap and 1.5-inch Polythemn Composite or (Optional if (Optional if using AA Base) LWC-14 vented steel Approved GArGLAs OMG CR 7-inch o.c. in ACFoam 11, H_ HA min. 0.5-Inch Structodek HA using AA Ply) One or more SBS-AA, SBS- at max. 5 It cellular LWC #75 BSF two, equally Shield, Multi- High Density Fiberboard BP -AA BP -AA or APP- TA, APP-TA -45.0 spaced center Max FA3 or Roof Insulation on or min. spans rows Polytherm 0.75-inch FescoBoard TA (homogeneous) Min. 22 ga., 7-Inch D.C. at Min. 1.5-inch Type B, Min. 300 psi GAFGLAS OMG CR 4-inch lap and 7-Inch o.c. in ACFoam 11, H- (Optional) One SBS-SA, APP- LWC-15 vented steel Approved #75 BSF two, equally Shield, Multi- HA None N/A SBS-SA or more SBS-SA SA, SOS -TA -45.0 at max. 5 It cellular LWC spacedcenter Max FA3 or or APP-TA or AP. TA spans Polytherm I rows Exterior Research and Design, I.I.C. d/b/a Trinity) ERD Certificate of Authorization #9503 6"EDITION (2017) FBC NON-HVHZ EVALUATION Prepared by: Robert Nleminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Evaluation Report A42970.10.12-R2 for FL16027-R2 Revision 2:09/25/2017 Appendix 1, Page 16 of 26 TJ TfSRINITY! ERD TAU�' COt4CRETEDECO�;F4MCONStAUcTibNokRER60F.(TgAi -biq ,LE4�lIGHTWEIG#iT SYSTEMTYPE E:,MECHA"NIiCALLY, A"TTACHEd BASE'SHEET, BONDED ROQFCOER 7Q System Deck Base Sheet (Note A below) Roof Cover (Note 15) Type No. (Note 1) Lightweight Concrete (Note 14) MDP (Note A) Fasteners Attach (Psf) 'CiFiNiRle CELLBIAR LIGHTWEIGHT INSULATING CONiRUE': -It Min cellular . 300 psi, min. 2-inch thick cel M n. 22 go., type B steel LWC. Note; To qualify the LWIC under is this 7-inch o.c. in a 3-inch lap and 7-Inch o.c. in (Optional) LWC 16 max 5 ft spans or assembly, an OMG CR BPF short achieve El OMG CR BPF] two, equally spaced, staggered rows in the One or more SEIS-AA, App- -45.0 structural concrete an average withdrawal of 53 lbf when field of the sheet BP -AA TA tested per rAS 105 or ANSIISPRI FX-1 'CELCORE CELLULAR LIGHTWEIGHT INSULATING CONCRETE '. Min. 0.0179-Inch Tensilform 5-75 or min. Trufast FM-90 8-inch o.c. in a 3-Inch lap and 16-inch o.c. in LWC-17 0.0205-inch Tensilform Min. 200 psi, min. 2-inch thick Celcore B1, 32, B3 or B7 or two, equally spaced, staggered rows in the One or more SEIS-AA 37.5 75 at max. 5 it spans or OMG CR BPF field of the sheet BP -AA structural concrete Min. 22 go., type B steel Trufast FM-90 or 7-inch o.c. in a 3-inch lap and 7-inch o.c. in One or more LWC-18 at max 5 it spans or Min, 200 psi, min. 2-inch thick Celcore B1 through B12 two, equally spaced, staggered rows in the SBS-AA -45.0 structural concrete OMG OR BPF field of the sheet BP AA Min. 26 go., type HIF 31, B2, B3, B4, 9-inch o.c. in a 3-inch lap and 9-inch o.c. in LWC-19 steel at max 5 ft spans Min. 225 psi, min. 2-inch thick Celcore MF B7, BE, 310, Ell OMG CR BPF two, equally spaced, staggered rows in the One or more L-AA -45.0 or structural concrete or B12 field of the sheet BP -AA Min. 22 go., type B steel 81, 82, B3, B4, 7-Inch o.c. in a 3-inch lap and 14-inch o.c. in LWC-20 at max 6 it spans or Min, 225 psi, min. 2-inch thick Celcore MF 87, BE, B10, B11 OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP -AA Min. 22 go., type B steel Bit, B2, B3, B4, 9-inch o.c. In a 3-Inch lap and 9-inch o.c. in LWC-21 at max 6 it spans or Min. 225 psi, min. 2-inch thick Celcore MF 87, B8, 310, ELL OMG CR BPF two, equally spaced, staggered rows in the One or more SBS-AA -45.0 structural concrete or B12 field of the sheet BP -AA Min. 22 go., type B steel Trufast Twin Lee- 9-Inch o.c. in a 4-inch lap and 18-Inch o.c. in One or more SBS-AA, SBS- LWC-22 at max 5 Ift spans or Min. 225 psi, min. 2-inch thick Celcore MF B1 or B2 two, equally spaced, staggered rows in the BP -AA or APP- -45.0 structural concrete Nall field of the sheet TA T A or APP-TA Min. 22 go., type B steel B2 (with poly- Trufast Twin Loc- 9-Inch o.c. in a 4-inch lap and 18-inch o.c. in One or more SBS-SA, APP- LWC-23 at max 5 it spans or Min. 225 psi, min. 2-inch thick Celcore MF film top surface) Nall two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete field of the sheet APP-TA or APP-TA Min. 22 go., type B steel 'WC-24 at max 5 it spans or Min. 300 psi, min. 2-Inch thick Celcorg MF 32 Trufast FM-90 8-inch o.c. in a 4-inch lap and 8-inch o.c. in BP -AA or APP- SBS-AA, SBS- -60.0 structural concrete I three equally spaced, staggered center rows TA TA or APP-TA Min. B2 (with poly- 8-inch o.c. in a 4-inch lap and 8-Inch o.c. in One or more SBS-SA, APP- LWC-25 at 1 300 psi, min. 2-Inch thick Celcore MF I I Trufast FM-90 I SBS-SA or SA SBS-TA I 60.0 structuralfilm top surface) three equally spaced, staggered APP-TA , or APP-TA Exterior Research and Design, I.I.C. d/b/a Trinity HERD Certificate of Authorization #9503 Prepared by; Robert Nleminen, PE-59166 6T'EDITION (2017) FBC NON-HVHZ EVALUATION TRI-BUILT Modified Bitumen Roof Systems; (8001516-1485 I Evaluation Report A4297 1'-R' 2for FL16027-R2 0* �Revlslo. 09/25/2017 A end" 1, Page 17 0126 1 TRINITY; ERD ' � r iEAROFF„;> IDRREROO( (::TABLE4CtLlGN,TWEIGHT.CONCREIEDECKS=NEW.CONSTRUCO. r "; E:'NCHANICALLWATTAC y OOERSY$LEV c• - - � NEDBSESHET,ONDEDOFCVTYRE .. , System Deck Base Sheet (Note A below) Roof Cover (Note 25) Type Na. (Note 1) Lightweight Concrete (Note 141 MDP (Note A) Fasteners Attach Base Ply Cap Ply (Psf) Min. 22 ga., type B steel Trufast FM-90 or ]-inch o.c. in a 3-Inch lap and 7-inch o.c. in One or more LWC-26 at max 5 ft spans or Min. 300 psi, min. 2-inch thick Celcore B3 through 812 two, equally spaced, staggered rows In the SBS-AA -75.0 structural concrete OMG CR BPF field of the sheet BP Min. 22 ga., type B steel LWC-27 at max 5 ft spans or Min. 300 psi, min. 2-Inch thick Celcore MF Polyglass Trufast FM-260 10-inch o.c. in a 4-inch lap and 30-inch o.c. in (Optional) BP- SBS-AA, SBS- -90.0 structural concrete Elastobase Poly three equally spaced, staggered center rows AA or APP-TA TA, APP-TA kELASTRELLCELLULARLIGHTWE1GW INSULATING CONCRETE. a i Min. 0.0179-Inch Tensilform 5-75 or min. Min. 200 psi, min. 2-Inch thick Elastizell Trufast FM-90 or 7.5-inch o.c. in a 3-inch lap and 7.5-inch o.c. One or more SBS-AA, SBS- LWC-28 -Inch Range II el through B12 OMG CR BPF in two, equally spaced, staggered rows in the or APP- -30.0 it spTensans o 75 at max.5 ft spans or 750.at field of the sheet TA 7q TA or APP-TA structural concrete MIn.0.0179-inch Tensilform 5-75 or min. Min. 200 psi, min. 2-inch thick Elastizell 82 (with poly- Trufast FM-90 or 7.5-inch o.c. In a 3-inch lap and 7.5-inch o.c. One or more SBS-SA, APP- LWC-29 Range II film top surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -30.0 75 at 75 a[ max. 5 ft spans or field of the sheet APP-TA or APP-TA structural concrete Min. 22 ga., type B steel Min. 200 psi, min. 2-Inch thick Elastizell Trufast FM-90 or 7-Inch o.c. In a 3-Inch lap and 7-Inch o.c. One or more I SB5-AA,SBS- LWC-30 at max ft spans or Range II Bl through B12 OMG CR BPF two, equally spaced, staggered rows in the BP -AA or APP- 7A or APP-TA -45.0 structural concrete field of the sheet TA i Min. 22 ga., type B steel Min. 200 psi, min. 2-Inch [hick Elastizell B2 (with poly- Trufast FM-90 or Inch o.c. In a 3-Inch lap and 7-inch o.c. In One or more SBS-SA, APP- -;SBA LWC-31 at max 5 ft spa or p Range II film top surface) OMG CR BPF t7 two, equally spaced, staggered rows In the SBS-SA or SA, -45.0 structural concrete field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel Min. 350 psi, min. 2-Inch thick Elastizell Trufast Twin Loc- 6-inch o.c. In a 4-inch lap and 6-inch o.c. In SBS-AA, SBS- LWC-32 at max 5 ft spans or with Zell -Crete Fibers, supple -mentally B2 Nails (min. 1.8- three, equally spaced, staggered rows in the One or more TA, SB5-SA, -60.0 structural concrete attached with Roofgrip H21 and 3-inch inch) field of the sheet BP -AA APP-TA or plates at 1 per B ft2 APP-SA Min. 22 ga., type B steel Min. 350 psi, min. 2-inch thick Elastizell with Zell -Crete Fibers, supple -mentally B2 (with poly- Trufast Twin Loc- 6-inch o.c. in a 4-inch lap and 6-inch o.c. in SB5-SA or SBS-SA, APP- LWC-33 at max 5 ft spans or attached with Roofgrip 421 and 3-inch film top surface) Nails (min.1.8- three, equally spaced, staggered rows in the APP-TA SBS-T SASBS-TA -60.0 structural concrete plates at 1 per 8 f12 inch) field of the sheet ar, EE..A „MEAtutRSLLr LW-_ 4.x....r,.rn:i`AG' Min. 24 ga., type B steel Trufast FM-90 or 7.5-Inch o.c. in a 3-Inch lap and 10-inch o.c. One or more LWC-34 at max5 ft spans or Min. 200 psi, min. 2-inch [hick Mearlcrete Bl through 612 In two, equally spaced, staggered rows in the SBS-AA -30.0 I structural concrete OMG CR BPF field of the sheet BP AA Exterior Research and Design, I.I.C. d/b/a Trinity H ERD Evaluation Report A42970.10.12-R2 for F1.16027-112 Certificate of Authorization 49503 6r"EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 18 of 26 TRINITY I ERD ;TABLE 4C: WGHTWEIGFjT CON' RETE,DECKS ' NEW CONSTRUCTION oR REROQF(TEAR �° -, MTYPE E;'NIECHANICALLY'ATTACHED BASE SHEET, BONDED ROOF.COVER , 2= _ . Base Sheet (Note A below) Roof Cover (Note 151 System Deck Lightweight Concrete (Note 34) MDP Type No. (Note 1) (Note A) Fasteners Attach Base Ply Cap Ply (Psi) Min. 22 ga., type B steel Trufast FM-90 7-inch o.c. in a 4-Inch lap and 7-inch o.c. in One or more LWC-35 at max 5 it spans or Min. 300 psi, min. 2-Inch thick Mearlcrete B3, B2 or 812 or two, equally spaced, staggered rows In the BP -AA or APP- SBS-AA, - SBS -45.0 structural concrete OMG CR BPF field of the sheet TA TA or APP-TA Min. 22 ga., type B steel B2 (with poly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-Inch o.c. in One or more SBS-SA, APP- LWC-36 at max 5 It spans or Min. 300 psi, min. 2-inch thick Mearlcrete film [op surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -45.0 structural concrete I I field of the sheet APP-TA or APP-TA Min. 22 ga., type B steel B1 82, 63, 87 or Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-Inch o.c. in One or more A, LWC-37 at max 5 It spans or Min. 300 psi, min. 2-inch thick Mearlcrete gl OMG CR BPF two, equally spaced, staggered rows in the BP -AA or APP- -52.5 structural concrete field of the sheet TA or TA TA or APP-TA Min. 22 ga., type B steel B2 (with poly- Trufast FM-90 or 7-inch o.c. in a 4-inch lap and 7-inch o.c. in One or more SBS-SA, APP- LWC-38 at max 5 it spans or Min. 300 psi, min. 2-inch [hick Mearlcrete film top surface) OMG CR BPF two, equally spaced, staggered rows in the SBS-SA or SA, SBS-TA -52.5 structural concrete field of the sheet APP-TA or APP-TA A. Base Sheets options are coded as follows: B3: Polyglass G2 Bose; B2: Polyglass Elastobase or Polyglass Elastobase Poly; B3: GAFGLAS #75; B4: GAFGLASStrotovent Nallable Venting Bose Sheet; 85: GAFGLAS Ply 4; 136: GAFGLA.S FlexPly 6; B7: JM Perma Ply No. 28; B8: JM Vensulation; B9: JM GlasPly IV; B10: JM GlasPly Premier, B31: Tomko Glass -Base; B12: Tomko Vapor -Chan Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.30.12-R2 for FL16027-RZ Certificate of Authorization 49503 6P EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (900) 516-1485 Appendix 1, Page 19 of 26 '\ TRINITY ERD "•�* " TABLESA.CEMENTRIOUS'WOOp � � FIBER pECI(S=NENICQNSTRUCIONoR NEROOF(TFAR OFF), � � �, <-. :�^ INSULATION, 'SYSTEM TYPE A-I:BONDED BONDED,ROOFCOVER" System Deck Base Insulation layer Top Insulation layer Roof Cover (Note 15) MOP No. (Note 1) Type Attach Type Attach Base Ply Ply Cap Ply (psf) Min95+GInch ACFoam II, Min. 0.25-Inch Dens Deck, Dens Deck Prime, (Optional) One or CWF-1 Min. 2.5-inch Tectum 150therm, D-IS or SECUROCK Gypsum -Fiber Roof Board or min. 0.5- D-IS or BP -AA more BP -AA or APP- S85-AA, SBS-TA, -45.0 Plank or Tectum LS Plank 08500 Inch Structodek High Density Fiberboard Roof OR500 APP-TA ENRGH-Shield, POIy[herm, ENRGY-3 Insulation TA Min. 2.5-inch Tectum Min. 1.5-Inch ACFoam II, D-IS or Min. 0.25-inch Dens Deck, Dens Deck Prime, D-IS or SBS-SA or (Optional) One or SBS-TA, SBS-SA, CWF-2 Plank or Tectum LS Plank 15095+GL, H-Shield, OB500 SECUROCK Gypsum -Fiber Roof Board OB500 APP-TA more SBS-SA or APP-TA, APP-SA -45.0 Polytherm, ENRGY-3 APP-TA Min. 0.25-Inch Dens Deck, Dens Deck Prime, Min. 2.5-Inch Tectum Min. 1.5-Inch ACFoam II, SECUROCK Gypsum -Fiber Roof Board or min. B.S. (Optional) One or SBS-AA, SBS-TA, CWF-3 Plank or Tectum LS Plank 15095+GL, CA-20 Inch Structodek High Density Fiberboard Roof CR-20 8P-AA more BP -AA or APP- APP-TA -52.5 ENRGY3 -H-Shleld Polytherm, NRG Insulation TA Min. 2.5-Inch Tectum Min.1.5-Inch ACFoam II, Min. OZ5-inch Dens Deck, Dens Deck Prime, SBS-SA or (Optional) One or 585-TA, 585-SA, CWF 4 Plank or Tectum Plank ISO 95+GL, H-Shield, CR-20 SECUROCK Gypsum -Fiber Roof Board CR-20 APPTA I more SBS-SA or APP-TA, APP-SA -52.5 Polytherm, ENRGY-3 I I I APP-TA Exterior Research and Design, LLC, d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization N9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (900) 516-1485 Appendix 1, Page 20 of 26 TRINITY I ERD : ABLE SB. CENIENTITIOUS,WOOD FIBERDECICS—NEW CONSTRUCTION OR REROOF(TeAR-OFF)` SYSTFrM,TYPEA2: MEfHANICALL&_ATTACHED ANCHOR SHE E'�, BONDED1[�SULATIONj BONDED'ROQFC01(ER 7.' System Deck Anchor Sheet Base Insulation Top Insulation Roof Cover (Note 15) MDP No. (Note 1) Type Fastener Attach Type Attach Type Attach Base Ply Ply Cap Ply (Psf) Min. 1.5-inch Min. 0.25-inch Dens Deck, Dens MIn.2.5-Inch Polyglass 9-inch o.c. in 4-Inch ACFoam IIACFoam , Deck Prime, SECUROCK Gypsum- (Optional) Tectum Plank Elastobase, Trufast lap and 12-inch o.c. III, ISO95+GL, H- Fiber Roof Board, Min. 0.75-inch One or more SBS-AA, CWF-5 or Tectum LS Polyglass Inuldek in two, equally ShieldENRGY 3, HA FescoBoard(homogeneous) or HA BP -AA BP -AA or SBS-TA, -30.0" Plank Elastobase Poly, Loc-Nail spaced, staggered , Polytherm or Multi- min. 0.5-inch Struaodek High APP TA APP-TA Polyglass G2 Base center rows Density Fiberboard Roof Max FA3 Insulation Polyglass 9-Inch o.c. in 4-Inch Min. 1.5-inch Min. 2.5-inch Elastobase, Trufast ,lap and 12-Inch o.c. ACFoam II, ACFoam Min. 0.25-Inch Dens Deck, Dens SBS-SA (Optional) SBS-TA, CWF-6 Tectum Plank Polyglass Inuldek in two, equally III, IS095+GL, H- HA Deck Prime, SECUROCK Gypsum- HA or APP- One or more SBS-SA, -30.0- or Tectum LS Elastobase Poly, Loc-Nail spaced, staggered Shield, ENRGY 3, Fiber Roof Board TA SBS-SA or APP-TA, Plank Polyglass G2 Base center rows Polytherm or Multi- APP TA APP SA Max FA3 Min. 0.25-Inch Dens Deck, Dens Polyglass 9-Inch o.c. in 4-Inch Min. 1.5-Inch - Deck Prime, SECUROCK Gypsum - Min. 2.5-inch Elastobase, Trufast lap and 1B-inch o.c. ACFoam II, ACFoam Fiber Roof Board, Min. 0.75-inch (Optional) SBS-AA, CWF-7 Tectum Plank Polyglass Twin in two, equally III, GL, H- HA FescoBoard (homogeneous) or HA BP -AA One or more 5B5-TA, -45.0• or Tectum LS Elastobase Poly, Lac -Nail spaced, staggered , ENRGY 3, Shield, EN min. 0.5-inch Struc[odek High BP -AA or APP-TA Plank Polyglass G2 Base center rows Polytherm or Multi- Density Fiberboard Roof APP TA Max FA3 Insulation Polyglass 9-inch o.c. in 4-inch Min. 1.5-Inch Elastobase, Trufast lap and 16-inch o.c. ACFoam+GL,Hoam Min. 0.25-inch Dens Deck, Dens 585-SA (Optional) SBS-TA, CWF-B Tectur5Pnch Tectum Plank Polyglass Twin In equally III, 15095+GL, H- HA Deck SECUROCK Gypsum- HA or APP- One or more SBS-SA, -45.0' or Tectum LS Elastobase Poly, Loc-Nail spaced spaced, staggered Shield, ENRGY 3, Roof Bo Fiber Roof Board TA SBS-SA or APP-TA, Plank Polytherm or Multi- APP-TA APP-SA Polyglass G2 Base center rows Max FA3 Exterior Research and Design, U.C. d/b/a Trinity)ERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization R9503 bra EDITION 12017) FBC NON-HVH2 EVALUATION i Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 5164485 Appendix 1, Page 21 of 26 TRINITYi ERD CEIV)ENTITIOUS,INOOD FIBER DECKS —NEW REROOF('fEAR-OFF)DR RECOVER e ._�, ,,. -CONSTRUCTION, as LT,YpE Bp NJECHANICALLY ATTACHED BASE INSULATION, ',BONDED,TOp INSUlATIOH;BONDEDRO�OFCOVER ,SYSTEM System Base Insulation Layer Top Insulation layer I Roof Cover (Note 15) MOP No. Deck (Note 1) Type Fasteners Attach Type Attach Base Ply Ply Cap Piy (psf) Min. 2.5-Inch Min. 2-inch H- OMG Polymer GypTec Plate Min. 0.5-inch Structodek (O (Optional if using (Optional If using AA SBS-AA, CWF-9 Tectum Plank or Shield or with Polymer GypTec or TruFast 1 per 4 ft z High Density Fiberboard HA Ply) BP AA Base) One or more BP -AA SBS-TA, I .45.0" Tectum LS Plank Polytherm TL 3 In. Plate with TL Fastener Roof Insulation or APP-TA APP-TA ,\;TABLESD;CEMENTITIOUSWOODF16ERDECkS NEWCONSTRUCTIONREROOF(Tenk-OFF)oRRECOVER - '' `. SYSTEaTYPEC;'MECHANICALLY` ATTACHED INSULATION;BONDED ROOF COVER: System Top Insulation Layer Roof Cover (Note 151 MDP Deck (Note 1) Base Insulation Layer No. Type Fasteners Attach Base Ply Ply Cap Ply (psf) Min. 2.5-Inch (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Prime (Optional if using AA SBS-AA, WF-10 Tectum Plank or more layers, any or SECOROCk Gypsum -Fiber Roof Board or Trufast Twin Loc-Nails r 1 per 2 R (Optional if using Base) One or more BP -AA SBS-TA; -45.0" Tectum LS Plank combination, loose Structodek High Density (min. 1-inch embedment) AA Ply) BP -AA or APP-TA APP-TA laid fiberboard Roof Insulation Fiberboard D F16ER ECKS NEW LONSTRUCI'IONOR REROOF(TFAR-OFF)'. SYSTEM TYPE EE NQNINISULADILIS OMECHAN ) ICALLY,ATTACHED-BASESHEET, BANDED ROOF COVER System Base Sheet Roof Cover (Note 35) MDP No. Deck (Note 1) (psf) Base Fasteners Attach Base Ply -Cap Ply Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Inuldek 9-inch o.c. in 4-Inch lap and 12-Inch ox. in two, (Optional) One or SBS-AA, SBS-TA, CWF-11 or Tectum LS Plank Poly, Polyglass G2 Base Lac -Nail equally spaced, staggered center rows more BP -AA or APP-TA APP-TA -30.0' Min. 2.5-inch Tectum Plank Polyglass Elastobase, Polyglass Elastobase Trufast Twin Loc. 9-Inch o.c. in 4-Inch lap and 18-inch ox. In two, (Optional) One or SBS-AA, SBS-TA, CWF-12 or Tectum LS Plank Poly, Polyglass G2 Base Nails equally spaced, staggered center rows more BP -AA or APP-TA APP-TA -45.0 Exterior Research and Design, U.C. d/b/a Trinity HERD Evaluation Report A42970.10.12-R2 for FL36027-R2 Certificate of Authorization 89503 6'"EDITION (2017) FBC NON-HVH2 EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 22 of 26 TRINITY ERD EDI NSULITINBONCEDlSfST5M TYPE A-i: BOND I System Deck (Notes I & 12) I Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP Type Attach Type Attach Base Ply Ply Cap Ply No. (psf) G-1 Existing, sound Poured gypsum Min. 2.0 pcf, Insulfoarn OB500 (Optional) additional layers(s) of base OBSOO SBS-SA (Optional) One SBS-SA, APP-SA -112.5 or gypsum plank deck Insulation or more SBS-SA G-2 Existing, sound poured gypsum Min. 1.5-inch ACFoam 11, ENRGY 3 or (Optional) additional layers(s) of base (Optional) One SBS-SA, APP-SA, or gypsum plank deck H-Shield OB500 Insulation OB500 00 SBS-SA or more 5BS-SA SBS-TA or APP-TA -112.5 orAPP-TA G-3 Existing, sound poured gypsum Min. 1.5-inch ACFoam 11, ENRGY 3 or Min. 0.25-inch SECUROCK Gypsum- (Optional) One SBS-SA, APP-SA, or gypsum plank deck H-Shield or min. 2.0 pcf, lnsulfoam OBSOO Fiber Roof Board OB500 SBS-SA or more SBS-SA SBS-TA or APP-TA -112.5 or APP-TA Existin& sound poured gypsum Min. 1.5-inch ACFoam 11, ENRGY 3, (Optional) additional layers(s) of base (Optional, On IBI-'A' APP-SA, G-4 or gypsum plank deck H-Shield or Multi -Max FA3 M-OSFA insulation and/or min. 0.25-inch M-OSFA SBS-SA or more SBS-SA SBS-TA or APP-TA -202.5 . SECUROCK Gypsum -Fiber Roof Board or APP-TA G-5 Existing, sound poured gypsum Min. 1.5-inch, min. 2.0 pcf Insulfoarn CR-20 (Optional) additional layers of base CR-20 SBS-SA (Optional) One SBS-SA, APP-SA -240.0 or gypsum plank deck insulation or more SBS-SA G-6 Existing, sound poured gypsum Min, 1.5-inch, min. 2.0 pcf Insulfoam CR-20 Min. 0.25-inch SECUROCK Gypsum- CR-20 SBS-SA (Optional) One or more SBS-SA SBS-SA, APP-SA, -240.0 or gypsum plank deck Fiber Roof Board SBS-TA or APP-TA orAPP-TA Existing, sound poured gypsum Min. 0.25-inch Dens Deck, Dens (Optional if using (Optional if using AA Base) One or I SBS-AA, SBS-TA, G-7 or gypsum plank deck Deck Prime or SECUROCK Gypsum- CR-20 None N/A AA Ply) more BP -AA or APP-TA -245.0 Fiber Roof Board I I I BP -AA APP-TA Existm& sound poured gypsum Min. 1.5-inch ACFoam 11, ACFoam III, I (Optional) additional layers(s) of base (Optional) One G-8 or gypsum plank deck I ENRGY 31 H-Shield, H-Shield CG or I CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA I or oreSBS-SA SBS-SA, AP-257.5 Multi -Max FA3 I SECUROCK Gypsum -Fiber Roof Board or 'P-TA SBS-TA or Exterior Research and Design, I.I.C. d/b/a Trinity I ERD Evaluation Report A42970.10.12-R2 for F1.16027-112 Certificate of Authorization 49503 EDITION (2017) FBC NON-HVHZ EVALUATION I Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (8o0) aii-uss Appendix 1, Page 23 of 26 1 TRINITY ERD ` 4A6LE68 GYPSUM DECKS=REROOP(T¢AR•QFFj '; e • `yet - [;il SYSTaMTYPEA-2:" MECHANICALLYATTAC`HED ANCHOR SHEET BONDED INSULATION,BfJNDEDROOPCOVER-,,,,,� Anchor5heet Base Insulation Top Insulation Roof Cover (Note 15) System No. Deck (Note 3) Type Fasteners (Note 13) Attach Type Attach Type Attach Base Ply Ply Cap Ply MDP (psf) 9-inch o.c. in 4- Min. 1.5-Inch Min. 0.25-inch Dens Deck, Dens Existing, sound Polyglass Trufast FM- inch lap and 18- ACFoam II, ACFoam Deck Prime, SECUROCK Gypsum - (Optional) ) poured gypsum Elastobase, 75 or FM- inch in two, III, H- Fiber Roof Board, Min. 0.75-inch One more SBS-AA, G 9 or gypsum Polyglass 90or Twin leyo. equally spaced, Shield,ISOENGL, 3, HA Fescoeoard (homogeneous) or HA BP -AA A BP -AA or SBS-TA, -45.0• plank deck Elastobase Poly, Loc-Nails staggered center yther or Polytherm or Multi- StructodekRoof High Density APP TA APP-TA Polyglass G2 Base Finch Density Fiberboard Roof rows Max FA3, Insulation c TABLE 6C:fDECKS- ' .GYPSUM —REROOR.(TEAR-OFF)oa RECOVERS' SYSTEM, TYPE C: MECHANICALLY ATTACHED INSULATION;BONDEDROOF COVER = - P - System Deck (Note 1) Base Insulation Top Insulation Layer Roof Cover (Note 1S) MDP Type Fasteners (Note 11) Attach Base Ply Ply Cap Ply No. Layer (psf) (Optional) One or Min. 0.25-inch Dens Deck, Dens Deck Existing sound more layers, any Prime or SECUROCK Gypsum -Fiber Trufast Twin Loc- r (Optional if (Optional if using AA ease) One SBS-AA, SBS- G-10 poured gypsum or combination, loose Roof Board Nails (min. lper 2 ft using AA Ply) or more BP -AA or APP-TA TA, APP-TA -45.0• gypsum plank deck laid Hor igh Density ib High Density Fiberboard nt)inch embedment) BP -AA Roof Insulation Roof Insulation - TABLE 66:'GYPSUM DECKS- REROOF(TEAR-OFF) -�- _' , ,- .SYSTEM TYPE Et NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET, 80NDIED ROOF COVER System Base Sheet Roof Cover (Note 15) MDP No. Deck (Note 1) Base Fasteners (Note 11) Attach Base Ply Cap Ply (psf) Existing sound poured Polyglass Elastobase, Polyglass Elastobase Trufast FM-75 or FM-90 or 9-inch o.c. in 4-inch lap and 18-inch o.c. In (Optional) One or more SBS-AA, SBS-TA, G-11 gypsum or gypsum Poly, Polyglass G2 Base Twin Loc-Nails two, equally spaced, staggered center rows BP -AA or APP-TA APP-TA -45.0• plank deck Exterior Research and Design, LLC. d/b/a Trinity I ERD Evaluation Report A42970.30.12-R2 for FL36027-R2 Certificate of Authorization N9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nienninen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 24 of 26 I 1 L TRINITY; ERD F •1 1:=BONDED INSU(.ATION_,BONDED ROOF COVER"': _ �.. ,,. _3YSTEIVITPPEiA System Base Insulation Layer Top Insulation layer Roof Cover (Note 15) MDP No. Substrate Type Attach Type Attach Base Ply Ply Cap Ply (psf) Existing (Optional) additional layers(s) of base (Optional) One SBS-SA, P-SA, R-1 Min. 1.5-inch Multi -Max FA3 D-IS insulation and/or D-IS SBS-SA -67.5 asphaltic roof SECUROCK Gypsum -Fiber Roof Board psumFiber Roof Amore SBS-SA or APP-TA r SBS-TA or APP-TA Existing (Optional) additional layers(s) of base (Optional) One or more R 2 asphaltic roof Min. 2.0 pcf Insulfoam D-IS insulation D-IS SBS-SA SBS-SA SBS-SA, APP-SA -90.0 Existing Min. 1.5-inch ACFoam II or ENRGY 3 or min. D-IS Min. 0.25-Inch SECUROCK Gypsum -Fiber D-IS SBS-SA (Optional) One or more SBS-SA, APP-SA, -g0.0 R-3 asphaltic roof 2.0 pcf Insulfoam Roof Board SBS-SA or APP-TA SBS-TA or APP-TA Existing (Optional) additional layers(s) of base (Optional) One more SBS-SA, PP-SA, R-4 asphaltic roof Min. 1.5-inch ACFoam II or ENRGY 3 D-IS insulation and/or min. 0.25-Inch D-IS SBS-SA SBS-SA or APP-TA SBS-TA orAP-T-TA -90.0 SECUROCK Gypsum -Fiber Roof Board R-5 Existing Min.1.5-inch, min. 2.0 pcf Insulfoam 08500 (Optional) additional layers of base OB500 SBS-SA (Optional) One or more SBS-SA, APP-SA -120.0 asphaltic roof insulation SBS-SA Existing Min. 0.25-Inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-6 asphaltic roof Min. 1.5-Inch, min. 2.0 pcf Insulfoam OB500 Roof Board OB500 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -120.0 Existing Min. 1.5-inch ACFoam II, ENRGY3 or H- (Optional) additional layers(s) of base (Optional) One or more SBS-SA, APP-SA, R-7 OB500 insulation and/ormin. Inch OB500 SBS-SA -127.5 asphaltic roof Shield SECUROCK Gypsum -Fiber Roof Board psu iber R SBS-SA or APP-TA SBS-TA or APP-TA Existing Min. Inch ACFoam II, ENRGY 3, H- M- (optional) additional layers(s) of base (Optional)One SBS-SA, APP-SA, R-B insulation and/or min. Inch SBS-SA -157.5 asphaltic roof l or Shield or Multi -Max FA3 OSFA iber R SECUROCK Gypsum -Fiber Roof Board OS OSFA Amore SBS-SA or APP-TA SBS-TA or APP-TA R 9 Existing Min. 2.0 pcf Insulfoam CR-20 (Optional) additional layers(s) of base CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA -240.0 asphaltic roof insulation SBS-SA Existing Min. 0.25-inch SECUROCK Gypsum -Fiber (Optional) One or more SBS-SA, APP-SA, R-30 asphaltic roof Min. 2.0 pcf Insulfoam CR-20 Roof Board CR-20 SBS-SA SBS-SA or APP-TA SBS-TA or APP-TA -240.0 Min. 1.5-Inch Ultra -Max or Multi -Max FA-3, (Optional) additional layers(s) of base Existing min. 1.3-Inch ACFoam 111 or min. 1.0-inch CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA (Optional) One or more SBS-SA, APP-SA, -240.0 R-11 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY SECUROCK Gypsum -Fiber Roof Board SBS-SA or APP-TA SBS-TA or APP-TA 3 Existing (Optional) additional layers(s) of base (Optional) One or more neonP-TA SBS-SA, APP-SA, R-12 asphaltic roof Min.2-Inch ACFoam II, ENRGY-3 or H-Shield CR-20 insulation and/or min. 0.25-inch CR-20 SBS-SA SBS-SA SBS-TA or APP-TA 247.5 SECUROCK Gypsum -Fiber Roof Board Existine Min. 0.25-inch Dens Deck, Dens Deck BP- AASBS- (Optional) One or more SBS-AA, SBS-TA or R-13 asphaltic roof Min. 1.5-inch Muiti-Max FA3 D-IS Prime or SECUROCK Gypsum -Fiber Roof D-IS SA, APP-TA BP -AA of APP-TA APP-TA -6r.5 Board Existing Min. 35-inch ACFoam II or ENRGY 3 or min. Min. 0.25-Inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, 585-TA or R-14 asphaltic roof 2.0 pcf Insulfoam D-IS Prime or SECUROCKGypsum-Fiber Roof D-IS SA, APP-TA BP -AA or APP-TA APP-TA -90.0 Board Exterior Research and Design, U.C. d/b/a Trinity HERD Evaluation Report A42970.10.12-R2 for FL16027-R2 Certificate of Authorization 49503 EPEDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Merriman, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 25 of 26 \JTRINIlY j ERD u =`� ;TABLE 7A•:RECOVER�IPPLICATIONS c , ' ,5 r_ j z ,` r TYPEA L,BONDEDINSULATIONr B4OJJDED�R00FCOwit. .. -, -, -, , .-,SYSTEM System Base Insulation Layer Top Insulation Layer Roof Cover (Note 15) MDP No. Substrate I Type Attach Type Attach Base Ply Ply Cap Ply IPsQ Existing Min. 1.5-inch ACFoam II, ENRGY 3, H-Shield Min. 0.25-inch Dens Deck, Dens Deck BP -AA SBS- (Optional) One or more SBS-AA, SBS-TA or R-15 OB500 Prime or SECU ROCK Gypsum -Fiber Roof OB500 -127.5 asphaltic roof or ISO 95+GL Board SA, APP-TA BP -AA or APP-TA APP-TA Existing Min.1.5-inch ACFoam II, ENRGY 3, H-Shield M- Min. 0.25-inch SECUROCK Gypsum -Fiber M- BP -AA SBS- (Optional) One or more 5BS-AA, SBS-TA or R-16 asphaltic roof or Multi -Max FA3 OSFA Roof Board OSFA SA, APP-TA BP -AA or APP-TA APP-TA -157.5 Min. 1.5-inch Ultra -Max or Multi -Max FA-3, Existing min.1.3-Inch ACFoam III or min. 1.0-inch CR-20 Min. 0.25-Inch SECUROCK Gypsum -Fiber CR-20 BP -AA (Optional) One or more SBS-AA -225.0 R-17 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY Roof Board BP -AA 3 or min. 2.0 pcf Insulfoam Min. I.5-Inch Ultra -Max or Multi -Max FA-3, Existing min. 1.3-Inch ACFoam III or min. 1.0-Inch CR-20 Min. 0.25-Inch SECUROCK Gypsum -Fiber CR-20 APP-TA (Optional) One or more APP TA -232.5 R-18 asphaltic roof ISO 95+GL, H-Shield, H-Shield CG or ENRGY Roof Board APP-TA 3 or min. 2.0 pcf Insulfoam r :TABLE 76RECOVER APPLICATIONS SYSTEM TYPEF NON-INSULATEDj�BONDED BASESHEET, BONDED ROOF COVER System Roof Cover (Note 25) MDP Deck Primer No. � Base Ply Ply I Cap Ply (Psf) R-19 Existing ASTM D41 BP -AA (Optional if using asphalt applied Ply) (Optional if using asphalt applied Base)BP-AA or APP-TA SBS-AA, SBS-TA,.APP-TA -45.0 asphaltic roof I Exterior Research and Design, I.I.C. d/b/a Trinity HERO Evaluation Report A42970.10.12-R2 for FL16027-RZ Certificate of Authorization #9503 6r" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2: 09/25/2017 Prepared by: Robert Nieminen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; (600) 516-1485 Appendix 1, Page 26 of 26