Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEI7U:iu[[IM111 .r FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: Standard Pacific RB Stamford Lot 43 Builder Name: Standard Pacific Homes 1 ,.3 _ �n , I Street: ��3I W Permit Office: St. Lucie - - �i City, State, Zip: Port 1. Luci , L , H Permit Number: Owner: Standard Pacific Homes Jurisdiction: I ,.,O UDesign Location: FL, Fort Pierce tI n I 1. New construction or existing New (From Plans) 9. Wall Types (3971.5 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 3646.00 fta b. Frame - Wood, Adjacent R=11.0 325.43 Its 3. Number of units, if multiple family 1 c. N/A R= t fz 4. Number of Bedrooms 4 d. N/A R= ftz 5. Is this a worst case? No 10. Ceiling Types (3540.0 soft.) Insulation Area a. Under Attic (Vented) R=30.0 3540.00 ftz 6. Conditioned floor area above grade (ftz) 3540 b. N/A R= ftz Conditioned floor area below grade (ftz) 0 c. N/A R= IS 11. Ducts R ftz 7. Windows(965.0 soft.) Description Area a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 6 640 a. U-Factor: Dbl, U=0.60 472.06 its SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.59 288.00 ftz 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.32 a. Central Unit 57.0 SEER:15.00 c. U-Factor: Dbl, U=0.77 136.00 ftz SHGC: SHGC=0.22 13. Heating systems kBtu/hr Efficiency d. U-Factor: other (see details) 68.99 ftz a. Electric Heat Pump 56.0 HSPF:8.50 SHGC: other (see details) Area Weighted Average Overhang Depth: 8.469 ft. Area Weighted Average SHGC: 0.300 14. Hot water systems 8. Floor Types (3540.0 soft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 3540.00 ftz b. Conservation features EF: 0.910 b. N/A R= Its None c. N/A R= Its 15. Credits Patel Total Proposed Modified Loads: 48.94 Glass/Floor Area: 0.273 PA!iSS Total Standard Reference Loads: 66.00 I hereby certify that the plans and specifications covered by Review of the plans and this calculation are in compliance with the Florida Energy specifications covered by this w&O Code. eigilallysgnetlbyChrisWildro tll eN: an W Idraudl, c US, calculation indicates compliance p `�. y ✓' Chris 0. Enginecredar LLC,ou New ConsWcrron Sates and with the Florida Energy Code. , '� & PREPARED BY: Ea meetag- __ _ Before construction is completedg ,,j wen ee,eaan . DATE: W/Iid-r-udt this building will be inspected for compliance with Section 553.908 'Y , wm- Dale: 20141230 10:58:57 OS'eg' I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Cop','.- n' , _ Q� OWNER/AGENT: �lL-�IlJ=- BUILDING OFFICIAL: -- y DATE: �i�Il� DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with 403.2.2.1.1. - Compliance requires completion of a Florida Air Barrier and Insulation Inspection Checklist - Heat sys #1 may be undersized. Size of 56.0 was increased to 69.8 for simulation. Please review the Manual J8 report. SCANNED BY St. Lucie County 12/30/2014 10:56 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 .P PROJECT Title: Standard Pacific RB Stamford Bedrooms: 4 Address Type: Lot Information Building Type: User Conditioned Area: 3540 Lot # 43 Owner: Standard Pacific Homes Total Stories: 1 Block/SubDivision: Riverbend # of Units: 1 Worst Case: No PlatBook: Builder Name: Standard Pacific Homes Rotate Angle: 0 Street: Permit Office: St. Lucie Cross Ventilation: County: --St.-Lucie - - Jurisdiction: Whole House Fan: City, State, Zip: Port St. Lucie , Family Type: Single-family FL, New/Existing: New (From Plans) - Comment: CLIMATE / IECC Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_ST_LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 3540 37945.9335 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 AC 1 First Floor 3540 37945.9326 No 5 4 1 Yes Yes Yes FLOORS # Floor Type Space_ Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio AC 1 First Floor 372 If 0 3540 ft2 0 0 1 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V If Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Barrel tile 3959 ft2 0 ft2 Medium 0.65 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 300 3540 ft2 N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type_ 1 Under Attic (Vented) AC 1 First Floor 30 3540 ft2 0.11 Wood 12/30/2014 10:56 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 6 WALLS Adjacent Cavity Width Height Sheathing Framing Solar Below IDt Tn Space Wall Type p R- /awe Ft In Ft in Area R-N/nhie Frart on Ahenr (:rsda% 1 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.4 0 0.4 0 2 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 10 0 10.67 0 106.6999 0.4 0 0.4 0 3 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13 0 10.67 0 138.7100 0.4 0.4-- 0 4 E Exterior Concrete Block - Int Ins= 1 First Flo 4.1 12 0 10.67 0 128.0400 0.4 _0 0 0.4 0 5 S Exterior Concrete Block - Int InsX 1 First Flo 4.1 80 0 10.67 0 853.5999 0.4 0 0.4 0 6 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 13.5 0 10.67 0 144.0449 0.4 0 0.4 0 7 W Exterior Concrete Block - Int InsW 1 First Flo 4.1 34 0 10.67 0 362.7799 0.4 0 0.4 0 8 W Exterior Concrete Block- Int InsAC 1 First Flo 4.1 20 0 12.67 0 253.3999 0.4 0 0.4 0 9 N Exterior Concrete Block - Int InsAG 1 First Flo 4.1 14 0 10.67 0 149.3800 0.4 0 0.4 0 10 N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 24 0 10.67 0 256.0800 0.4 0 0.4 0 11 N Garage Frame - Wood AC 1 First Flo 11 8 0 10.67 0 85.36000 0.4 0.4 0 12 W Garage Frame - Wood AC 1 First Flo 11 6 0 10.67 0 64.02000 0.4 0.4 0 13 W Exterior Concrete Block - Int InsAC 1 First Flo 4.1 18 0 10.67 0 192.0599 0.4 0 0.4 0 14- N Exterior Concrete Block - Int InsAC 1 First Flo 4.1 50 0 10.67 0 533.5 f12 0.4 0 0.4 0 15 S Exterior Concrete Block - Int InsAC 1 First Flo 4.1 6 0 10.67 0 64.02000 0.4 0 0.4 0 16 E Garage Frame - Wood AC 1 First Flo 11 16.5 0 10.67 0 176.0550 0.4 0.4 0 _ 17 S Exterior Concrete Block - Int InsW 1 First Flo 4.1 12 0 10 0 120 W 0.4 0 0.4 0 18 E Exterior Concrete Block - Int InsAC 1 First Flo 4.1 20.5 0 10 0 205 Its 0.4 0 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 W Insulated AC 1 First Flo None 0.6 2.67 0 8 0 21.36 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. / Wall Overhang V # Orni ID Frame Panes NFRC U-Factor SHGC Area Depth Separation Int Shade Screening 1 E 1 Metal Low-E Double Yes 0.77 0.22 48 ft2 23 it 0 in 2 ft 0 in None None 2 E 1 Metal Low-E Double Yes 0.4 0.31 21.28000 23 it 0 in 2 It 0 in None None 3 E 2 Metal Low-E Double Yes 0.77 0.22 48 ft2 13 it 0 in 2 ft 0 in None -None 4 E 3 Metal Low-E Double Yes 0.6 0.31 16.17000 6 It 0 in 2 ft 0 in None None 5 E 4 Metal Low-E Double Yes 0.77 0.22 40 fR 8 ft 0 in 2 ft 0 in None None 6 S 5 Metal Low-E Double Yes 0.6 0.31 116.9783 1.33 ft 0 i 2 it 0 in None None 7 S 5 Metal Low-E Double Yes 0.6 0.31 22.68000 1.33 ft 0 i 2 ft 0 in None None 8 S 5 Metal Low-E Double Yes 0.6 0.31 9.180000 1.33 It 0 i 2 ft 0 in None None 9 S 6 Metal Law-E Double Yes 0.59 0.32 80 ft2 18 it 0 in 2 it 0 in None None 10 W 7 Metal Low-E Double Yes 0.6 0.31 116.9783 1.33 It 0 i 2 ft 0 in None None 11 W 8 Metal Low-E Double Yes 0.59 0.32 128 fly 12 ft 0 in 4.67 it 0 i None None 12 W 8 Metal Low-E Double Yes 0.4 0.31 24.88439 12 it 0 in 1 fl 0 in None None 13 N 9 Metal Low-E Double Yes 0.59 0.32 80 ft2 18 it 0 in 2 it 0 in None None 14 N 10 Metal Low-E Double Yes 0.6 0.31 22.68000 9 it 0 in 2 it 0 in None None _ 15 W 13 Metal Low-E Double Yes 0.6 0.31 58.48919 1.33 it 0 i 2 It 0 in None None 16 N 14 Metal Low-E Double Yes 0.6 0.31 27.34560 1.33 ft 0 i 2 it 0 in None None 12/30/2014 10:56 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 6 WINDOWS Orientation shown is the entered, Proposed orientation. / _V # 17 18 _- 19 20 21 22 Wall Ornt ID Frame Panes NFRC N 14 Metal Low-E Double Yes N 14 Metal Low-E Double Yes N 14 Metal Low-E Double Yes N 14 Metal Low-E Double Yes S 15 Metal Low-E Double Yes S 17 Metal Low-E Double Yes Overhang U-Factor SHGC Area Depth Separation Int Shade 0.6 0.31 38.99279 1.33 ft 0 i 2 ft 0 in None 0.6 0.31 9.180000 1.33 ft 0 i 2 ft 0 in None 0.4 0.31 16.17000 1.33 ft 0 i 2 ft 0 in None 0.4 0.31 6.652800 1.33 It 0 i 2 ft 0 in None 0.6 0.31 13.67280 1.33 ft 0 i 2 ft 0 in None 0.6 0.31 19.71199 2 ft 0 in 1 ft 0 in None Screening None None None None None None GARAGE _ # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Height Exposed Wall Insulation 1 660 ft2 660 ft2 _Wall 72 ft 10 ft 1 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Best Guess 0.000500 4642.7 254.88 479.33 0.3650 7.3410 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump None HSPF: 8.5 56 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit Split SEER: 15 57 kBtu/hr 1710 cfm 0.75 1 sys#1 HOT WATER SYSTEM _ # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.91 50 gal 70 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cent # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / V # ---- Supply ---- ---- Return ---- Air Percent Location R-Value Area Location Area Leakage Type Handler CFM 25 Leakage ON RLF HVAC # Heat Cool 1 Attic 6 640 W Attic 160 ft2 Default Leakage AC 1 First F (Default) (Default) % 1 1 12/30/2014 10:56 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 6 TEMPERATURES Programable Thermostat: Y Ceiling Fans: Coolin f[`�x]JJan fj jFeb II` Mar j ] A r Ma IfX Jun frX Jul X Au X Se ff Oct [`��jJ Nov Dec Heating Jan [X] Feb Mar L J Apr I May Jun Jul lX� Nov f Venting I Jan II l l J Feb l� IXl Mar lxl (I [ Aug Sep Oct lnJ Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 66 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 12/30/2014 10:56 AM EnergyGaugeO USA - FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 6 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Performance Method ADDRESS: PERMIT #: Port St. Lucie, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details. COMPONENT SECTION SUMMARYOF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating and controls cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and / sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent / to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of = 1 & Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16113). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per Tables 503.2.3. Equipment efficiency verification required. Special / equipment occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. 12/30/2014 10:56 AM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 6 of 6 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 74 The lower the EnergyPerformance Index, the more efficient the home. Port St. Lucie, FL, 1. New construction or existing New (From Plans) 9. Wall Types Insulation 2. Single family or multiple family Single-family a. Concrete Block - Int Insul, Exterior R=4.1 b. Frame - Wood, Adjacent R=11.0 3. Number of units, if multiple family 1 c. NIA R= 4. Number of Bedrooms 4 d.N/A R= 5. Is this a worst case? 6. Conditioned floor area (ft2) 7. Windows- Description a. U=Factor: Dbl, U=0.60 SHGC: SHGC=0.31 b. U-Factor: Dbl, U=0.59 SHGC: SHGC=0.32 10. Ceiling Types Insulation No a. Under Attic (Vented) R=30.0 3540 b. N/A R= Area c. NIA R= 472.061t' 11. Ducts a. Sup: Attic, Ret: Attic, AH: AC 1 First Floor 288.00 ft2 c. U-Factor: Dbl, U=0.77 136.00 ft2 SHGC: SHGC-0.22 d. U-Factor: other (see details) 68.991? SHGC: other (see details) Area Weighted Average Overhang Depth: 8.469 It, Area Weighted Average SHGC: 0.300 8. Floor Types Insulation Area a. Slab -On -Grade Edge Insulation R=0.0 3540.00 ft2 b. N/A R= it- c. N/A R= IF 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Heat Pump 14. Hot water systems a. Electric b. Conservation features None 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: QMW �7 / Date: 2 (11 \ Address of New Home: \1%-) 9W typ�/��_ City/FL Zip: t�- Area 3646.00 ft2 325.43 ft2 ft2 ft2 Area 3540.00 ft2 ft2 ft2 R ft2 6 640 kBtu/hr Efficiency 57.0 SEER:15.00 kBtu/hr Efficiency 56.0 HSPF:8.60 Cap: 50 gallons EF: 0.91 Pslat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. **Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Stamford Model HVAC Load Calculations for Standard Pacific Homes EON It"\FIF i-I'�1A L.c�Ar 1\�Q� , Prepared By: Chris Wildroudt Engineered Air LLC CACO45860 2520 N Andrews Ave Ext Pompano Beach, FL 33064 954 974-7277 Monday, February 10, 2014 Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. --------------------- Pro'ect Report -------------------- ------ Designed By: Chris Wildroudt Project Date: - 2-10=14 Client Name: Standard Pacific Homes Company Name: Engineered Air LLC CAC045860 Company Representative: Chris Wildroudt Company Address: 2520 N Andrews Ave Ext Company City: Pompano Beach, FL 33064 Company Phone: 954 974-7277 Company Fax: 954 973-1883 Outdoor Outdoor Outdoor Indoor Indoor Grains Dry But Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference Winter: 42 39.4 n/a n/a 70 n/a Summer: 90 75 50% 50% 75 42 Square ft. of Room Area: Volume (ft3) of Cond. Space: 3,483 35,411 Total Sensible Gain: Total Latent Gain: Total Cooling Required Including Ventilation Air: Square ft. Per Ton: 831 r - 50,280 Btuh 50.280 MBH 43,180 Stuh 86 % 7,134 Btuh 14 % 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) rtnvac is an AUUA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM -0-77-SHGC-0 22 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 46.2 518 0 578 578 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 155.8 2,622 0 5,308 5,308 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 40 862 0 924 924 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 316.2 5,319 0 6,275 6,275 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 288 4,760 0 5,532 5,532 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 22.8 256 0 286 286 0.4, SHGC 0.31 1 U: Door -Metal - Fiberglass Core 21.4 192 0 192 192 13A-4ocs: Wall -Block, board insulation only, R-4 board 2476 9,915 0 5,417 5,417 insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud 304.1 311 0 311 311 6avity, no board insulation, brick finish, wood studs 1213-0sw: Part -Frame, R-11 insulation in 2 x 4 stud 205 298 0 298 298 cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic 3482.9 3,121 0 3,344 3,344 Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no 372 10,302 0 0 0 insulation below floor, any floor cover, passive, light dry soil Subtotals for structure: 40,544 0 30,017 30,017 People: 5 1,500 1,400 2,900 Equipment: 2,000 2,400 4,400 Lighting: 0 0 0 Ductwork: 3,017 428 2,591 3,019 Infiltration: Winter CFM: 218, Summer CFM: 112 6,719 3,206 1,848 5,054 Ventilation: Winter CFM: 0, Summer CFM: 0 0 0 0 0 AED Excursion: ...:. 0 0 4,924 4,924 Total Building Load Totals: 50,280 7,134 43,180 50,314 Total Building Supply CFM: 1,965 CFM Per Square ft.: 0.564 j Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (W) of Cond. Space: 35,411 S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM S stem 1 A 1 -First Floor Summary Loads Lo-17 rrencn uoor: uiazing-Low-t rrencn uoor, u-value -0.77, SHGC 0.22 - --- Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 0.4, SHGC 0.31 Lo-E operable: Glazing-Low-E Operable Glass, u-value 0.6, SHGC 0.31 Lo-E French Door: Glazing-Low-E French Door, u-value 0.77, SHGC 0.22 Lo-E operable: Glazing-Low-E Operable Glass, u-value 0.6, SHGC 0.31 Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value 0.59, SHGC 0.32 Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value 0.4, SHGC 0.31 11J: Door -Metal - Fiberglass Core 13A-'4ocs: Wall -Block, board insulation only, R-4 board insulation, open core, siding finish 12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud cavity, no board insulation, brick finish, wood studs 12B-Osw: Part -Frame, R-11 insulation in 2 x 4 stud cavity, no board insulation, siding finish, wood studs 16D-30: Roof/Ceiling-Under Attic with Insulation on Attic Floor (also use for Knee Walls and Partition Ceilings), Vented Attic, No Radiant Barrier, Dark Tile, Slate or Concrete, R-30 insulation 22A-pl: Floor -Slab on grade, No edge insulation, no insulation below floor, any floor cover, passive, light . __dry soil Subtotals for structure: People: Equipment: Lighting: Ductwork: Infiltration: Winter CFM: 218, Summer CFM:112 Ventilation: Winter CFM: 0, Summer CFM: 0 AED Excursion: System 1 AC 1 - First Floor Load Totals: 96 46.2 155.8 40 316.2 288 22.8 21.4 2476 304.1 205 3482.9 518 2,622 862 5,319 4,760 256 192 9,915 311 298 3,121 0 0 0 0 0 0 0 0 0 0 0 578 5,308 924 6,275 5,532 286 192 5,417 311 298 3,344 578 5,308 924 6,275 5,532 286 192 5,417 311 298 3,344 372 10,302 0 0 0 40,544 0 5 1,500 2,000 0 3,017 428 6,719 3,206 0 0 0 0 50,280 7,134 30,017 1,400 2,400 0 2,591 1,848 0 43,180 30,017 2,900 4,400 0 3,019 5,054 0 4,924 50,314 Check .:igitres Supply CFM: 1,965 CFM Per Square ft.: 0.564 Square ft. of Room Area: 3,483 Square ft. Per Ton: 831 Volume (ft3) of Cond. Space: 35,411 I otal Heating Hequired Including Ventilation Air: 50,280 Btuh 50.280 MBH Total Sensible Gain: 43,180 Btuh 86 % Total Latent Gain: 7,134 Btuh 14 % Total Cooling Required Including Ventilation Air: 50,314 Btuh 4.19 Tons (Based On Sensible + Latent) Rhvac is an ACCA approved Manual J and Manual D computer program. Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D. All computed results are estimates as building use and weather may vary. Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at your design conditions. S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Riverbend Stamford.rh9 Monday, February 10, 2014, 1:50 PM