Loading...
HomeMy WebLinkAboutPLANSDESIGN CERTIFICATION FOR WIND LOAD COMPLIANCE: 11 GARY POINELL. I CERTIFY THAT, TO THE BEST OF MY KNOWLE516E AND BELIEF, THESE PLANS AND SPECIFICATIONS HAVE BEEN DE516NED TO COMPLY WITH THE APPLICABLE STRUCTURAL PORTION OD THE BUILDING CODE AS AMENDED, ADOPTED, AND ENFORCED BY ST. LUCIE COUNTY BUILDING DEPARTMENT. I AL50 CERTIFY THAT THE STRUCTURAL COMPONENTS, SYSTEMS. AND RELATED ELEMENTS PROVIDE ADEQUATE RESISTANCE TO THE WIND LOADS AND FORGES SPECIFIED BY THE CURRENT CODE PROVISIONS. I HERBY ACCEPT RESPONSIBILITY FOR THE STRUCTURAL DESIGN. CODE EDITIONS: BUILDING DESIGN A5: BASK WIND SPEED: BUILDING CATEGORY: WIND IMPORTANCE FACTOR: INTERNAL PRESSURE COEFFICIENT: GARAGE DOOR PF516N PRESSURE: WINDOW DESIGN PRESSURE: WIND SPEED EXF05URE: IMPACT PROTECTION (EXTERIOR OPENIN(55): 2017 FLORIDA BUILDING CODE 6 EDITION A5CE -I-10 ENCLOSED WEST OF TURNPIKE_____ EAST OF TURNPIKE_ X I II X III IV r1p] SEE FLOOR PLAN FOR WIND PRESSURES SEE FLOOR PLAN FOR WIND PRESSURES FOR WINDOW5 AND DOORS IN INT. AN REND ZONES I80 MPH. Lrj APPROVED SHUTTERS IMPACT RE515TANT X GLASS (MUST BE INDICATED ON PERMIT DOCUMENTS FOR ALL RESIDENTIAL / COMMERCIAL BUILDIN65, ALTERATIONS, AND RENOVATIONS) NOTE: ACTUAL DESIGN PRESSURES FOR ALL EXTERIOR WINDOWS, DOOR, GARAGE DOORS, AND 51MILAR ENVELOPE ELEMENTS MUST AL50 BE INDICATEDON CONSTRUCTION PLAN5.5 DEMOLITION PLAN '0 /OI REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC SCANNED BY SCALE: 1. Lucie County 1/4" = 1'-0" ARCH 1 TEGTURE AND PLANNING 16 SOUTH RIVER ROAD SEWALLS POINT, FL. 540101(o OFFICE: "772-225-1'155 O LL UJ v Z UJ Q � la IX � O O H � f- U1 (� LU v Q Q � � Q is) U_ Q �--F-�-N 9) W U � z � O M I p 1.2 oto >n DRAM BY WGP CHECKED BY WGP DATE MAR. 2q, 201q SCALE A5 NOTED U� REVISIONS: FILE. COPY • ELECTRICAL 5PECIi=1CATIONS I DRAWIN65 ARE DIAGRAMMATIC AND SHALL NOT BE 50ALED REFER TO ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATION OF ALL EQUIPMENT. ELECTRICAL CONTRACTOR SHALL FURNISH AND INSTALL ALL ITEMS REQUIRED FOR A COMPLETE AND ACCEPTABLE WORKING INSTALLATION 2 ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE NATIONAL ELECTRICAL GORE AND SHALL COMPLY WITH ALL LOCAL RULES AND ORDINANCES HAVING JURISDICTION. S MINIMUM WIRE 51ZE SHALL BE a 12 AW6. UNLESS OTHERWISE NOTED. ALL CONDUCTORS SHALL BE COPPER WITH THWN OR THHN INSULATION. 4 ALL MATERIAL 5HALL BE NEW AND BEAR THE UNDERWRITE5 LABLE NL) WHERE APPLICABLE. 5 THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY &ROUNDED AS REQUIRED IN ARTICLE 250 OF THE NATIONAL ELECTRICAL CODE. 6 THE ELECTRICAL TELEPHONE AND GABLE TELEVISION INSTALLATIONS SHALL MEET ALL REQUIREMENTS BY THE LOCAL UTILITY COMPANIES. T ALL DISCONNECT SWITCHES SHALL BE RATED FOR 100,000 A.I.G. UNLESS OTHERWI5E NOTED. ALL FUSES SHALL BE RATED FOR 200,000 A.I.G. AND SHALL BE CURRENT LIMITING. 5 ALL ELECTRICAL SWITCH6EAR SHALL BE BY SQUARE D. ITE. OR CHALLEN6ER. SUBSTITUTES MUST BE APPROVED SY THE ENGINEER. 4 OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS. PLASTIC BOXES MAY BE USED IN LIEU OF THE STEEL BOX WHERE PERMITTED BY LOCAL CODES. IN DAMP OR WET LOCATIONS BOXES SHALL BE MADE FROM CAST ALLOY WITH THREADED HUBS. 5PECIAL ENCLOSURES ARE REQUIRED FOR OTHER CLA551FIED AREAS. 10 SEPARATE WIRE AND CONDUIT SYSTEM MAY BE SUBSTITUTED WITH FACTORY FABRICATED ASSEMBLY OF INSULATED CONDUCTORS IN A FLEXIBLE METALLIC ENCLOSURE WHERE PERMITTED BY LOCAL CODES. II MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC WITH OVERLOAD RELAYS IN EACH HOT LE6. IT SHALL BE THE ELECTRICAL CONTRACTOR TO PROVIDE ALL STARTERS WHERE REQUIRED. 12 FURNISH AND INSTALL DISCONNECT SWITCHES OVER CURRENT PROTECTION, AND WIRING FOR THE AIR CONDITIONING SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED BY THE AIR CONDITIONING CONTRACTOR AND CONNECTED BY THE ELECTRICAL CONTRACTOR. 19 ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE AND ACCEPTED BY THE ENGINEER OR ARCHITECT. 14 ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID INTERFERENCE WITH THE PROGRESS OF CONSTRUCTION. 15 THE ELECTRICAL CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (U ONE YEAR FROM THE DATE OF ACCEPTANCE. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHITCH MAY HAVE BEEN DAMAGED THEREBY. 16 ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION A5AIN5T PUBLIC LIABILITY OR PROPERTY DAMAGE FOR THE DURATION OF THE WORK, E X. LA`✓ EX. 2" VTR GO I > 1 1/2" NEW LAV EXI5T6. 2" SANITARY LINE ELECTRICAL 5YMBOL5 I"X4" (2 7USE) FLUORE5E147 LIGHT CL& MTO ® RECESSED LIGHT 4 WALL MOUNTED LIGHT ,II 6 IIO V DUPLEX OUTLET 6. 1IOV DUPLEX OUT. GROUND FAULT PROTECTED ® SPECIAL PURPOSE OUTLET $ 5WITCH O EXHAUST FAN JQ-- TELEVISION OUTLET OTV b TELEPHONE OUTLET WIP1 ELEC PANEL FLOOD LGT. ® IIOV SMOKE DETECTOR W/ BATT BACKUP SANITARY RISER NTS. PLUMBING NOTES: I. PROVIDE WATER -HAMMER ARRESTORS ON ALL QUICK GLOSINS VALVE5. PER F.B.G. 2gO5.5 / MFSR. SPECS. 2. PROVIDE A WATER HEATER RELIEF VALVE $ PIPING TO EXTERIOR GREEN AREA. 3. PROVIDE AN APPROVED DEVICE FOR THERMAL EXPANSION CONTROL ON ON ALL ELECTRIC WATER HEATERS (5TORA6E WATER HEATING EQUIPTMENT). PER F.B.C. 2gO5.4. REVISED FLOOR FLAN SCALE: 3/16" = I'—O" GAR"'' FONELL ARCHITECTURE AND PLANNING 16 SOUTH RIVER ROAD OFFICE: FL. 34gg6 -1-72-223-gg43 Lu v z w w o lu Q w 0 0 lu o lu W Q v O 2 � z z p � Q Z z Z � O � H � � Q lf1 i PRAIM BY WGP GFlEGKED SY YNGP VATE MAR. 28, 201 cl SCALE AS NOTED NO. Ia REVISIONS1 A==2 1) STRUCTURAL NOTES: A. STRUCTURAL DRAWINGS SHALL BE WORKED TOGETHER WITH ARCHITECTURAL, MECHANICAL AND ELECTRICAL DRAAN&5 TO VERIFY DIMENSIONS, LOCATIONS OF DEPRESSED SLABS, SLOPES, DRAINS, OUTLETS, RECESSES, RESLEETS, BOLT SETTINGS, SLEEVES, ETC. DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO PROCEEDING WITH THE WORK B. ALL STRUCTURAL OFENIN65 AROUND OR AFFECTED BY MECHANICAL, ELECTRICAL OR PLUMBING BWIPTMENT SHALL BE VERIFIED WITH EQUIPTMENT PURCHASED BEFORE PROCEEDING WITH STRUCTURAL WORK AFFECTED. CONTRACTOR SHALL SUBMIT TO THE STRUCTURAL ENGINEER FOR APPROVAL A ORAWI1,16 DETAILING THE OPENIN65, LOCATIONI5 AND SIZE PRIOR TO CONSTRUCTION. NO PENETRATIONS OF ANY STRUCTURAL MEMBER NOT SHOWN ON THE STRUCTURAL DRAWIN65 WILL BE ALLOWED WITHOUT PRIOR APPROVAL OF THE STRUCTURAL ENGINEER. C. ALL WORK TO BE PREFORMED IN ACCORDANCE WITH ALL STATE, COUNTY, AND OR MUNICIPAL CODES AND ORDINANCES. D. CONTRACTOR SHALL OBTAIN THE LATEST SET OF DRAWINGS INCLUDING ANY REVISIONS BEFORE STARTING CONSTRUCTIONS. E. ALL DETAILS, SECTIONS AND NOTES SHOWN ON THESE ORAWIN65 ARE INTENDED TO BE TYPICAL AND SHALL APPLY TO SIMILAR 511UATIONS ELSEWHERE UNLESS NOTED OR SHOWN. F. COMPUTED DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALED DIMENSIONS. S. WHEN SPECIFICATIONS AND GENERAL NOTES DISA&REE, &ENERAL NOTES SHALL TAKE PRECEDENCE. 2) ELEVATIONS: .q, SEE PLANS FOR FINISH FLOOR ELEVATIONS, FOOTING, COLUMN AND BEAM HM&H75. 5) CONCRETE: A. COMPRESSIVE STREN&TH OF CONCRETE AT 28 DAYS F'G= Sp00 P51. B. TEST: A MINIMUM OF 5 CONCRETE 5PECIMAN5 SHALL BE TAKEN FROM EACH 50 CU. YD. OR PORTION THEREOF. SPECIMANS SHALL BE TESTED ACCORDINI6 TO ASTM A-Sq, ONE AT 3, ONE AT 7AND 5 AT 28 DAYS. C. REINFORCING COVER: CONCRETE DEPOSITED A&AINLST THE 6ROUND..............................3. FORMED CONCRETE AGAINST THE GROUND..................... - .............. " BEAMS AND COLUMNS..................................................................................1 1/21, SLABS....................... _..-..-............................. -................. -..-..- ....................... .3/4„ SLABS ON 61POUNIP (BOTTOM) .................... ................. ........ ......... - ..... I" R/T SLABS EXPOSED EXPOSED TO N✓FATHER........................ - ..... I" 14"X 14" RECESS IN — SLAB TO CONSEALL BOLTS (FILL SOLID lov GROUT 12"X 12" X 5/4" BASE - PLATE W/ (40 5/8" X 8" EWAN510H BOLTS 4) SLAB ON FILL: PLACED IN ACCORDANCE WITH AGI 502 A. VAPOR BARRIOR: WATERPROOF MEMBRANES (OVERLAPPED 6" AT JOINTS) WITH PERMEANCE OF LESS THAN 0.3 PERMS IN ACCORDANCE WITH ASTM E-qb SHALL BE PROVIDED UNDER INTERIOR SLABS. B. P44ERE NO VAPOR SARRIOR IS USED THE SUE36RADE MUST BE DAMPED WITH WATER IN ADVANCE OF CONCRETING. NO FREE WATER 57ANDIN6 ON THE SOIL NOR ANY MUDDY OR SOFT SPOT 15 PERMITTED. C. ANY STRUCTURAL MEMBER PENETRATING SLABS ON FILL 15 TO BE ISOLATED WITH 1 1/2" THICK PRE -MOLDED JOINT FILLER COMPLYING WITH A5TM 0-1752, TYPE. D. FINI5HIN6- NO PREMATURE FINISHING SHALL BE ALLOWED. IMMEO ATLY FOLLOWING FLOATING TROWELING WITH STEEL TROWELS SHOULD BE COMMENCED IF REQUIRED. BROOMIN& SHALL BE DONE AFTER THE STEEL TRO10EL.IN6 OPERATION. 5) REINFORCING STEEL. A. REINFORCING BARS CONFORIN6 TO ASTM A-615 6RADE 60, INCLUDING COLUMN AND BEAM TIES. B. WELDED ARE FABRIC CONFORMING TO A57M A-165 AND SUPPORTED ON SLAB BOLSTERS SPACED AT 5'-O"OC. C. FABRICATION AND DETAILING ACCORDING TO AGI-515. D. ALL ACZESSORIES TO HAVE UPTURNED LESS AND BE PLASTIC DIPPED AFTER FABRICATION. 6) MA50NKY WALLS: A. BEARING MASONRY SHOWN IN PLAN SHALL BE ERECTED PRIOR TO THE STRUCTURE ABOVE BEING POURED. B. NON-BEARIN* MASONRY SHOWN O IN PLAN SHALL BE ERECTED AFTER THE CONCRETE STRUCTURE IS POURED AND ALL SHORING HA5 BEEN REMOVED. HOLD CLEAR OF OVERHEAD CONCRETE UNTIL ANTICIPATED DEFLECTION HAS OCCURED. C. MORTOR, CONFORMING TO A5TM C-270, TYPE "M" (2500 F51) D. CONCRETE LINTELS, OPENIN65 UP TO W-O" 8" X 4" WITH 2 • 4 OPENIN65 UP TO 8'-0" 8" X 4" WITH 2• 4 TOP AND BOTT. E. PROVIDE DOVETAIL ANCHORS AT INTERSECTION OF NON -BEARING MASONRY WITH STRUCTURAL CONCRETE COLUMNS AND WALLS. NEW 48" X 46" X 16" Y1/ 5 05 EACH WAY BOTT. NlEA 1 •5 X 50" LONG DOWELS AT 12" OC. DOWELED INTO EXIST*. CONC. SLAB MIN. 6" AND SET IN HI&H 5TREN&TH EPDXY &ROUT AND CA51" INTO NEW FOOTING (ALL 4 61DE5) EXIST&. 4" CONC. SLAB 2 F0071 N& DETAIL. SCALE: 5116" D. CONCRETE LINTELS: OPENIN(95 UP TO 4'-0" 8" X 4" WITH 2 P 4 OPENIN&5 UP TO 81-0" 8" X 4' WITH 2 • 4 TOP AND BOTT. E. PROVIDE DOVETAIL ANGHOR5 AT INTERSECTION OF NON -BEARING MASONRY WITH STRUCTURAL CONCRETE COLUMNS AND WALLS. 7) GENERAL BEAM SCHEDULE NOTES. A. SCHEDULE HOOPS OR STIRRUPS SHALL BE PLACED AT EACH END OF BEAM NOTED OTHERWISE. B. BUNDLE ALL STRUCTURAL BEAM TOP BARS IN PAIRS OVER SUPPORT WITH TOP BAR FROM ADJACENT BEAM. C. ALL CONCRETE BEAMS OTHER THAN THOSE WITH THE PREFIX TB SHALL BE POURED PRIOR TO PLACING THE BLOCK BELOW. D. ALL THE BEAM REINFORCING SHALL Be CONTINUOUS THRU BEAMS ONLY. E. ALL THE BEAM TOP REINFORCING SHALL EXTEND INTO SPAN OF ANY ADJACENT STRUCTURAL BEAM AS PER BENDING DIAGRAM. R DROP BOTT. OF BEAMS AS REQUIRED AT WINDOW AND DOOR HEADS (25" MAX.) AND ADD 2 • 5 5AR5 BOTT. IF DROP EXCEEDS 5". &. THE BEAM SCHEDULED DEPTHS ARE MINIMUMS AND MAY BE INCREASED (8" MAXIMUM TO FIT BLOCK WORK). H. ALL ADDED LONGITUDINAL BEAM REINFORCING SHALL EXTEND 8" MINIMUM INTO SUPPORTS UNLESS OTHERWISE NOTED. I. PROVIDE 2 • 5 CORNER BARS AT ALL BEAM INTERSECTIONS ( 50" LEGS MINIMUM ) 6) nMBER A. ALL TIMBER TO HAVE A MINIMUM 5TRE55 &RAVE P. 1;200 P51 AND E.1,5000000 P51. B. ALL ROOF PI FMENT5 TO BE SECURED TO BEAM OR OTHER STRUCTURAL ELEMENTS WITH HURRICANE STRAPS. C. TRU555 MANUFACTURER TO SUBMIT SHOP DRAWINGS SIGNED AND SEALED BY A FLORIDA ENGINEER. q) STRUCTURAL STEEL: A. CONFORMING TO ASTM A-56. B. BOLTS CONFORMING TO ASTM A-525 (U.NA) TYPE N. SCALE: 1/4" I'-O" (2) 1/2" THRU BOLTS C. PIPE COLUMNS CONFORMIN& TO ASTM A-55, GRADE S. D• PROVIDE ONE SHOP COAT OF RUST INHIBITING PAINT (MIN. 3 MIL. DRY THIGKNEE) E. FABRICATION AND ERECTION ACCORDING TO THE LATEST AI5C SPECIFICATIONS. F. SHOP DRANING5 MU5T BE SEALED BY THE MANUFAGTURER5 FLORIDA RE*15TERED ENGINEER BEFORE SUBMITTN6 FOR APPROVAL. 6, STRUCTURAL TUBES GOMFORMIN& TO ASTM A-500, 6RADE B. H. ALL BOLTED CONNECTIONS TO BE VERIFIED BY A TE5TIN6 LABORATORY. 10) WELDING: A. ALL WELDIN6 15 TO BE DONE BY A CERTIFIED WELDER B. ELECTRODES TO BE B-70 SERIES, LOW HYDROGEN (STORED ACC01;DIN6 TO A. W. 5. REQUIREMENT5 ) IU APPROVALS. A. SUBMIT SHOP DRAWINGS FOR ITEMS 5, 7, 8, q. B. SUBMIT CONCRETE MIX DESIGN. C. SUBMIT LABORATORY REPORTS FOR ITEM S. 12) COORDINATION: o _ _ Qi O1/4" WELD i ®5TL. ANGL' E DETAIL NT'S. �0 ry a 5 1/2" X 5 1/2" k X 3/5 STL. ^� COL. V (4) 1/2" BOLTS 2) 1/2" TH JOLTS 4" STL. P. ASSEMEL —1/4" CONT. WELD OF 5-1/2"50-1/ 5T_. COLU1 1/4" PLATE ASSEMBLY EACH 51DE OF GIRDER cV �3/4" BASE PLATE I II ®STL. ANGLE DE AIL NTS. NOTE VERIFY ROUGH OPENING FOR DOORS R WINDOWS W/ MF&R PRIOR CONSTRUCTION. GOLUMN 50HEDULE: Q ■ 5 1/2" X 5 1/2" X g" STL. COL. W/ 12"X 12" X 5/4" STL. BASE -SEE DETAILS FOR BAS AND GAP PLATE FOOTING SCHEDULE G 40" X 46" X 16" W/ 5 • 5 EACH WAY 5OTT. 501L BEARING 5TATEMEMT: 1. FOOTINI65 WERE DE516NED FOR A SOIL BEARING CAPACITY OF 2500 P5F. 2. GENMRAL CONTRACTOR SHALL VERIFY SOIL BEARING CAPACITY PRIOR TO CONSTRUCTION. PROVIDE 501L BEARING TE5T5 516N AND SEALED BY A STATE OF FLORIDA RES15TERED ENGINEER TO ARCHITECT FOR REVIEW PRIOR TO CONSTRUCTION. EXISTS. ROOF- 1RU55M AT 24" OC.. ANCHOR TO TOP PLATE W/ (2) 16 D ANILS EACH TRU55 DOUBLE 2" X 6" TOP PLATE 2" X 4" WOOD STUDS AT 16" or. 2" X 4" WOOD BOTT PLATE W/ 1/41X 6 TAP GON SCRENIS AT 16" OG. T EXISTS. GONG. SLAB} TYf�'IGrotL SHORING ^ALL SCALE: NT5 9-I/2"X3-I/2"XI/4" STL COL. CONT 1/4" WELD !4) 5/5" X 8" ANCHOR BOLTS EACH BASE PLATE 8"X8"XI/2" STL BASE PLATE. O COLUMN BASE FOUNDA71ON PLEAT SCALE: 1/4" &ARY PONELL ARCHITECTURE AND FLANN I NG 16 5OU7H RIMER ROAD OFFICE: "IR�HT FL. 34 aa6 i72-225-aa45 Il EW.Am BY N&F C+ec4cw BY WGF DATE SCALE �29a , 201 SCALE ASNOTED W� NO. la I�GY I��VI\•7i lu D N t` z