Loading...
HomeMy WebLinkAboutPOOL PAPERWORKGOODWIN RESIDENCE POOL Sr �GREG, INC. FILE COPY _� VIEWED FOVI E CODE C CIE COUNTy St. LU SOCC SCREEN ENCLOSURE THE PORCH FACTORY POOL AND SPA THE BE CENTEk%Er) GA HOUSE REVIEWED FOR CODE COMPLIANT ST. LUCIE COUNT BOCC FILE COPY DECK SQFT: 815 �� _ SPA RAISED 12" AIR SWITCH /7-- ABOVE DECK 1 SPA SPLIT LEVEL SPA i $ BENCH 18" / 21" / NICHELESS SPA LED + 12" WATERLINE TILE:GG8M2348B18 STEP TILE: GG8M2348B18 FLO-CRETE: BOMBAY EXPANSION JOINTS: WHITE INTERIOR FINISH: SKY BLUE CHILD BARRIER:BLACK ON BLACK SPA MAIN DRAIN DEPTH 3' 6" EDGE TILE DEC-O-DRAIN REMOVE EXISTING CONCRETE M -3' EDGE TILE 48" SPILLWAY NICHELESS POOL LED 10 MAIN DRAIN -12" DEPTH 6' 111 2.511 SPA RETURN LINE 2.5" REMOTE EQUIPMENT STAND 0 L� SPA MAIN DRAIN LINE 2.5" RETURN LINE 2.5" SKIMMER LINE 2" MAIN DRAIN LINE 2.5" VACUUM LINE 2" MAX WIDTH: 14' MAX LENGTH: 28' DEPTH: 3' 6" TO 6' PERIMETER: 84' SHAPE: RECTANGLE SQUARE FEET: 392 DIRT FROM EXCAVATION: LEAVE AND SPREAD LEAVE: NO LEAVE & SPREAD: YES LEAVE -MOVE -THEN SPREAD NO EXTRA FILL & COMPACTION NO JOB ENTRANCE: THROUGH GATE ON LEFT SIDE OF HOUSE 6 X 6 TILE: GG8M2348B18 INT FINISH: SKY BLUE STEP TILE: GG82348B18 ON STEPS FILTER: CLEAN & CLEAR 150 PUMP: INTELLIFLO VSF MOTOR H.P. 3 HP MAX TIME CLOCK: IN PUMP CHLORINATOR: ICHLOR -30 LIGHTS 2 POOL 1SPA GLOBRITES TRANSFORMERS 2 POOL CLEANER: DORADO VAC LINE 1 MAIN DRAIN: 32" CHANNEL SKIMMERS: 1 RETURNS: 4 SWIMOUT OR LADDER: SWIMOUT HANDRAIL: NONE FILL LINE: NONE OVERFLOW LINE: NONE SPA SPECS: 5' X 7' RECTANGLE RAISED V ABOVE POOL DECK SPA PUMP 2HP SUPERFLO SLIDE: NONE HEATER: ULTRATEMP 120C TANK: N/A VAC. HEAD: N/A VAC. HOSE 1 VAC POLE: 1 BRUSH: 1 LEAF SKIMMER: 1 TEST KIT: 1 OVERFLOW LINE: NONE FILL LINE: NONE TREE REMOVAL: NONE STUMP REMOVAL: NONE WATER & ELECTRICAL SUPPLY: REAR OF HOUSE ELECTRICAL HOOKUP: PAYUK RIGHT SIDE OF HOME BACKWASH LINE: STD BLUE FLAT LINE PATIO: 815 SQFT FLO-CRETE COLOR: BOMBAY EXISTING PATIO: REMOVE 69 SQFT TERMITE: STD DEC-O-DRAIN: WHITE FOOTERS: STD PL.':NTERS: M01E OVERPOUR: `.ES SCREEN ENCLOSURE: NONE SAFETY FENCE COLOR: NONE CUT & CAP SPRINKLERS: NONE APPROX GALLONS: 13,250 PUMP G.P.M. SEE ATTACHED SOLAR BY: NONE YES NO 6" X 6" X SHEET TILE _X_ OVERPOUR —X_ MOSAICS X_ -6„ P� CROpG� EN Designer: ROBERT WOOD L12 _ PE 68212 m : Address: 8886 S FEDERAL HWY City: PORT ST LUCIE FL 34982 ' TE Phone: 772-337-9713 ext20 Cell: 772-631-3948 0" M. R��Hd;�jl� i Qc(g', P.E. Email: robertbwood@att.net FL Lic. No. 68212 License #: CPC 1458338 1801 Hazelwood Drive Fort Pierce, FL 34982 PH: (772) 201-1634 CLIENT INFORMATION CLIENT SCANNED POOR ALARMS TO CODE APPROVAL Name: ASHLEY GOODWIN BY I have reviewed and I give my approval to proceed with the construction of this project. Lucie OU11 \ Address: 7201 SHANAS TRAIL tv --- x City: PORT ST LUCIE FL 34952 Cell: 954-410-5413 0_2 - n / p \ - Customer Date i �, Email: agoodwincontractors@gmaiLcom Y' PER Fr. MIN SLOPE WELL LP REMOVE GRATE & —� POINT A FROM MN POUR OR CAR TILE DRAIN ATTACH ACH AUX, PUMP WHERE APPLICABLE • . '`.,9',A'''' LINE WHEN EMPTYING POOL ,, ,•lL�; ;:,:; ;; �'.; ..` .. -, a 6"x6" TILE (2) #3 REBAR OR GRATE SHALL 4" SLAB BE SECURED IN INTERIOR 2500 FIBER MIX (1) #5 REBAR PLOOS —Pool construction complies with FBC 2017 ANSI—? ANSI-15 PLACE SO FINISH 41 TYP. WALL-3,000 PSI GUNITE S) —Water Velocity —Max 8ft sec as per FBC 2017—R4501.6.3 THAT TOOLS p ARE REQUIRED r_ —Pool Barrier to Comply with Section R4501 17-6th edition FBC FOR REMOVAL STEEL-TEX FORM /"�� OR KRAFT WALL M —Skimmers comply with FBC 2017—R4501.21.2 6" TYP. FLOOR '! � W. 8" i —Soil bearingcapacity assumed 2.000 si @95% corn action TRENCH DRAIN GUNITE PSI #3 ® 12" O.C.B.S - p y p p GUNITE NOTE: FOR DEPTHS —Equipment Foundation 3'x7' cone slab min 3.5" thick pour In r! GREATER THAN 6' ADDE� jN0 place or approved Hurricane Rated precast equipment pads TREADED .k , :: (1)#3 COVE BAR ®6' O.C. Q'r (,_ , —Water Heating equipment to comply with FBC 2017—R4501 U GRAVEL BE TO PUMP - TYP. WALL SECTION & WELL POINT FOOTER DETAIL (NO SCALE) WHEN PROVIDED SHALL BE AT 20" MAX BELOW THE WATERLINE SWIMOUTS (NO SCA ) PRESSURE GAUGES INSTALLED ON FILTER PUMP FOR FINAL INSPECTION I Vacuum (In Hg) X 1.13 Feet Of Head i Pressure (PSI) X 2.31 Feet Of Head Vacuum Head + Pressure Head = Total Dynamic Head HYDRO -STATIC RELIEF DEVICE INSTALLED IN AREAS THAT EXCEED WATER TABLE IN SHELL TRENCH DRAIN .5" POOL ,.5" SPA MAIN DRAIN POOL DETAIL (NO SCALE) OUTSIDE ANGLE OF REPOSE 6' AND FURTHER - 4' THICK WALLS W/#3 REBAR 012" O.C. EACH WAY 3' TO 6' - 6" THICK WALLS W& REBAR e12" O.C. EACH WAY 0' TO 3' - 8" THICK WALLS W/#3 REBAR 012° O.C. EACH WAY J 3 MISC, NOTES 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2x6 CAPTILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HANDHOLD TO BE INSTALLED ARE WHERE DECK RAISED +6" ABOVE POOL F� � EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE P,V SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES ' COMPACTION TEST OF THE BACKFILLED MATERIAL ARE PROVIDED PRIOR TO THE POURING OF THE PATIO 10" MIN 'a O , a STEPS (NO SCALE) N OVERPOUR OR CAP TILE WHERE APPLICABLE 6"x6" TILE 6"x6" TILE '^.:1 4" SLAB •'e'•' :' 2500 FIBER MIX SPA BENCH 18' ,t;• BELOW WATER LINE GRATE SHALL {,.'`:,',':. , +^;':; •...,:•,.•.. BE SECURED IN ^i• T PLACE SO •' •' �'• ' �'. 4Y2" TYP, WALL-3,000 PSI GUNITE LS If ARE REQUIRED 6" TYP ,.:A' • "'u i FOR REMOVAL FLOOR "'; +'::�•: "� STEEL-TEX FORM ."' a '•.f..;' OR KRAFT WALL TRENCH DRAIN f''..T•r.," #3 0 12" O.C.B.W. GRAVEL BE TO PUMP SPA WALL SECTION (NO SCALE) VENT UNE NOT TO BE FURTHER THAN 40 FT FROM POOL 25' MAX WET LENGTH DRAIN SPA DETAIL (NO SCALE) POOL PATIO WATER LEVEL UNDERWATER '! LIGHT '••li ^, i FILTER PUMP 11 TO 12 VAC FROM POWER SUPPLY SIZE AS DETERMINED BY LICENSED ELECTRICIAN \-- 1" PVC POOL FINISH CONDUIT STEP DETAILS 1. TREAD IS MIN OF 10" WIDE. SCHEDULE 40 PVC SLEEVE 2. RISER NOT GREATER THAN 12' EXCEPT IF ` NO BONDING MORE THAN (3) TREADS ARE USED �::'.�'; OR GROUND 3. ALL STEPS TO BE SOLID GUNITE 3000 P.S.I. . REQUIRED NICHLESS UNDERWATER LIGHT DETAIL (NO SCALE) CHLORINATOR HEATER 7 FILTER PUMP W/ HAIR & LINT STRAINER PUMP W/ HAIR & r— LINT STRAINER e HEATER BY-PASS PAD 3A3'_ DRNH CHANNEL ORp,\N CIFANEk p0OL 3°x3'L CNNNNF3- DftNN PIPING SCHEMATIC CUSTOM MOLDED PRODUCTS INC. SINGLE CHANNEL DUAL OUTLET CMP 25506-32X VGB PER FRC4501,8.e COMPLIANT 32" CHANNEL DRAIN COMPLIANT WIT 2017 FLORIDA BUILDING CODE LISTED TO ASME/ANSI AI12198 32" CHANNEL DRAIN AND SUMP 25506-320-000 "THREE 2" SOCKET x 2.5" SPIGOT PORTS *DEBRIS GUARD INCLUDED *38.79in? OPEN AREA *IAMPO LISTED FLOW RATES *WHITE PVC BODY *COVER GOES OVER BODY TO GIVE FINISHED LOOK TO PUMP The maximum flow rating for this suction fitting with the center port plugged and outer ports open is 308 GPM (floor) and 212 GPM (wall) when using 2.5 plumbing and 268 GPM (floor) and 192 GPM (wall) when using 2° plumbing. The maximum flow rating for this suction filling with the outer ports plugged and the center port open is 2GO GPM (floor) and 168 GPM (wall) when using 2.5' plumbing and 184 GPM (floor) and 176 GPM (wall) when using 2" plumbing. FILE COPY REVIEWED FOR CODE COMPLIANCE ST, LUCIE COUNTY DECK --\ 1 ROW OF WATERLINE TILE WATERLINE - WAX 8'-0" 1 #3 STEEL a 12` O/C E.W. VEL FLOOR L�— fi" THICK FLOOR SLOPES FLOOR SLOPE SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLEE 11t TMRu ssa THE OP OF THE BOOR FROM THE SHALOw END wAu TOWARDS THE DEEP AREA SHALL NOi fxCEm f FOOT IN r FOOT 5'-8" 19'-8" 3'—[ 2uo 8F 0' TYPICAL SECTION THRU POOL (NO SCALE) wao SN61.L NOT SLOPE GREATER THAN 11" Determine System Flow Rate: Minimum Flow Rate Required: 35 gpm per skimmer POOL 1. Calculate Pool Volume: __==___ft_==x 7.48(gal/Ft) _ _________gal PUMP (Surface Area) (Average Depth) (Volume in gallons) 2. Determine Flow Rate: —_ XXX___ gal / --- LxX --- _--- XXX _--+---XXX --_=XXX (Volume) (Turnover Minutes) (Pool Flow Rate) (Feature Flow Rate) (System Flow Rate) Determine Pipe Sizes: Trunk Piping to be 2_5_inch to keep velocity ® 8 fps max, at_ i5gpm Maximum System Flow Rate. Return Piping to be--2.5—inch to keep velocity 0 8 fps max. at 117—gpm Maximum System Flow Rate. Main Drain Cover( ------ . SEE—A80VE__--) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineeling Page for Drain Configuration Pump Model PENTAIR INTELLIFLO VS3050 H.P. 3 Total H.P: H.P.x service factor. I H.p. or more musk be 2 speed or variable speed Filter Make PENTAIR C&C Size 150 Fitter min. area based on 6hr, turnover flow rate pool gal.1360 min. =Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make ON PUMP Model ------ Controls must operate a minimum of two speeds. The hlaher soeed override is not to exceed one normal cycle or 24 his, whichever Is less Pipe Size 6 fps Sfps 1' 16 gpm 0.14' 21 gpm 0.23' 1,5' 37 gpm 0,08' 50 gpm 0.14' 2' 62 gpm 0.06' 82 m 0,10, 215' 88 gpm 0.05' gpm 17 0,09 3' 136 gpm 0.04' 181 gpm . 7' 4' 234 gpm 0,03' 313 gpm 0,05' 6' 534 gpm 0,02' 712 gpm Determine Pipe Sizes: HYDROS Trunk Piping to be_ 25inch to keep velocity ® 8 fps max. at_ 1 17_gpm Maximum System Flow Rate. Return Piping to be 2.5_inch to keep velocity 0 8 fps max. at_ 117_gpm Maximum System Flow Rate. Main Drain Cover(_____ SEE ABOVE____) System Flow Rate must not exceed approved cover flow rate. (Make and Model) See Engineering Page for Drain Configuration Pump Model PENTAIR SUPERFLO H.P. 2 Total H.P.=H.P.x service factor.1 H.p. or more must be 2 speed or variable speed Filter Make N/A Size --- Filter min area based on 6hi turnover flow rate pool gal. 1360 min. = Flow Rate Divide G.P.M. by Cartridge = .375 or Sand =15 or D.E. = 2 Time Controller make N/A Model ------ Controls must operate a minimum of two speeds. The higher seed override Is not to exceed one normal cycle or 24 his whichever Is less Pipe Size 6 fps Bfps 1' 16 gpm 0.14' 21 gpm 0.23' 1,5' 37 gpm 0.06' 50 gpm 0.14' 2' 62 gpm 0.06' 82 m 0.10' 2.5, 88 gpm 0.05' 17 gpm 0.09 3' 136 gpm 0,04' 181 gpm A7' 4' 234 gpm 0.03' 313 gpm 0,05' 6' 534 gpm 0.02' 712 gpm 0.03' DESIGNED FOR: POOLS BY GREG GOODWIN RESIDENCE 7201 SHANAS TRAIL PORT ST LUCIE, FL Q3� i Lmense _ * 1801 P162elwood Drive: g SfT9.ltocC 34982,' i ;P (772)201-163�4, �!V VIV// ***ELECTRIC NOT INCLUDED*** PREPARED BY: SHEET: STEVE HORST Y311 DRAFTING & DESIGN SERVICES 01.7846 horst,steve@yahoo,com 4/2 TDH CALCULATOR Pool Information PBG-GOODWIN-HIGH SPEED Flow Rate: 98,30 GPM Total Piping Lengths: Suction Lift: 2 Ft Inlet Side: 80 Ft Discharge Side: 134 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consult your local code) Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 In Inlet Piping: 8 Ft/Sec Discharge Piping: 8 FVSec Piping Hand Loss at 98.30 Gal/Min: (not incuding fittings or valves) Inlet Piping: 4.79 Ft Discharge Piping: 8.03 Ft Foradvanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for singly pump sytems with a single body of water. Results: Your TDH Calculation 3ugga.ted Minimum Pipe Sizes: Flow Rate: 98.30 Gal/Min Branch Piping: 3.0 In Your Head Lose: 79.57 Ft Inlet Piping: 2.5 In Maximum Flow Rate Discharge Piping: 2.5 In at Maximum RPM: 98.30 Got/Min Ensure the drain clover max how rating Is not exceeded. Head Loss at Maximum Flow Rate: 79.57 Ft System Head Pressure Curve 1so �'t00 S v 50 ... IntelliFlo Variable Speed VS+,6VRS, VF, or VSF - 3450 rpm '.. clean system Desired Operation Point ''.. q 0 50 100 Selected Components Components- ""L aaa N. 0A.Iy Naiades a.1.1 10-Al 1 2.66 3"t26"9wMVWe J "0" as ail I On CZae,GW I 8.22 UIcr Roo I JS,Oi VnNANum d LSJ Piping IMN Macs'. Nxtl beN x.m. tmemxy A ... ON a40as0am miss. Nbaw 0 19 1034 45tlepro.NMr/ 0 0 am T. TNAah 0 5 147 Pumps New quenON InW4FIO VA.Mmed.y8,8VR8.VF, I .IVW 4x PAaI ah, Mdiixv veoes,bVPeta..lne. aAkFsOr rea0eae EwTavit laff-MA,, S.Tcds Ad Ew&sled* em iseiane-A MdMOMeme,W MPonav Wek/Pm`uq Spa,Me. enPbrMaflili&dcamp.rvea In Ih. lhEed STeM.nNwalMr .4..ble. ciaeiepm¢Yy .W ,"nrefaW bre.d¢WIINM pM11u In.InuY O.Wadln#e ubampMam. sedm elan."Aaassw aMwMmwNbeM9en IM awM,e plMe¢e lamHMdd'MWNdWMNWMe,PoNMtlSpa, lnc. TMYMme.0ae hA,JNIK Dasaee.eaaaMbedemeM blMee apan,Ye.SueuM ws em amfinlroualylmp/wlrp ou,prohela entlaerviw¢, PeMehmervw IM ,,'AMmyf'AaAas..aA.1 v_. IMnvhansA.1aAAe,empd/er. ! y ! TDH CALCULATOR Pool Information PBG-GOODWIN-LOW SPEED Pool Volume: 13253 Gal Total Piping Lengths: Turn Over Time: 6.00 Hire Inlet Side: 80 Ft Suction Lift: 2 Ft Discharge Side: 134 Ft Maximum Pipe VolooltL ')owed: Piping Sizes: (consult your local code) �✓ ��/ Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 In Inlet Piping: 8 Ft/Sec Discharge Piping: 9 Ft/Sec .81 Piping Head Loss at 36Gal/Min: (not Incudtrrg fittinga or valves) Inlet Piping: 0.78 Ft Discharge Piping: 1.30 Ft For advanced pools that contain multiple suctions, this program may be inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water - Results: Your TDH Calculation Suggested Minimum Pipe Sizes: Flow Rate: 36.81 Gal/Min Branch Piping: 1.5 In Your Head Loss: 18.31 Ft Inlet Piping: 1.5 In Maximum Flow Rate Discharge Piping: 1.5 In at Maximum RPM: 98.30 Gal/Min ,Ensure the drain cover max flow rating is not exceeded. Head Lose at Maximum Flow Rate: 79.57 Ft 30 25 5 20 s System I -pd Pressure Curve ~ Intelll Flo Variable Speed, VS+SVRS, VF, or VSF - 1600 rpm Glean System ' Desired Operation Point j 0 10 20 30 40 Voiumetric Flow Rate (GPM) Selected Components Components x.m. aaMav ie r.' min rMnarlwlc-aa 1 .1 V i,1IV ave.ei a am MMO,em I a. cNeeMaea, 1 a. U're-, 1 94a i MM Ra- 4 as Piping We DlrtM1npa H,ai Weel Nanw oA.MN Q..w Or".011. mdyxeboe a 10 165 45Gq,n NWw a a am T. TMagh 0 5 0.24 Pumps Nine OaMly INVea W.W. eM, Vs,8VR8, VF, 1 or VW 4tt(4MablMMnw#entlbpai mo"nede,Palor Mc IWaVW tviRcasir EaeyT;eh* Inte Twice, Serus %Md ev Wiew ire NkaerAi*.c nNa, tltlimeM. dpaAsr me. Podsa Spa, j_..ri AAss. M IM ever ssa, ea,., AN, muMHe is N'nsa ded M.Wa sAaAdid Mdas.lMl a, La u.W. as dMwneM.'c.. m M...-Ass , i.imeMb . . ftow,"Iedfias a sii.e ve awaf Pon armlaP dad Sp, Inc. n.-A.taians ntl,.,Nse 'a"'. ,wmpioeei.allw .'s MWpAl4s esug xnMiwuyyimpmxnpaw FlManl4,ndaWiea,. P.Mev msamaln. npnlroaarp gesiMe6wv urawutpvw lWiur. PmmxuenepweppmtunlNMVbn,. ELECTRICAL EQUIPMENT WIRING, GROUNDING AND INSTALLATION MUST CONFORM TO THE 2017 N.E.C. AND APPLICABLE LOCAL CODES 30" WIDE a 8 8" HIGH z SO" DEPTH CLEAR WORKING SPACE IN FRONT OF ANY PANEL BOARD PER 110.26(A), 110.26(2) AND 110..e,8(3) OF THE 2017 NATIONAL ELECTRCC CODE aaavaus SFORMEF ""'"AUNCTI� (S) OIO of B" C 11MER W/S.T. REVE POOL DECK W LE -SWITCH' -'-'POOL DEAPROVIDRa C CONDURNUTER rfBSOUD PROOF C,F I. NOT BE MOREYTHAN 72 IN.MUST 20' FROM POOL" CMDREDGE AND NOTWITHIN 8' OF POOL E001SOLD'COPPER WIREZZ EOlAPOiEMNL BONO N.E.C. 2017 SEC. 680,A2(3 COPPER WIRE TO GROUND bu FILE COPY STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) TDH CALCULATOR Pool information PBG-GOODWIN-SPA Flow Rate: 95 GPM Total Piping Lengths: Suction Lift: 2 Ft Inlet Side: 76 Ft Discharge Side: 80 Ft Maximum Pipe Velocity Allowed: Piping Sizes: (consul your, local code) Inlet Piping: 2.445 In Branch Piping: 6 FVSec Discharge Piping: 2.445 In Inlet Piping: 8 Ft/Sec Discharge Piping: 8 FVSec Piping Hand Loss at 96.00 Gal/Min: (roe incuding fittings or valvess) Inlet Piping: 4.28 Ft Discharge Piping: 4.50 Ft For advanced pools that contain multiple suctions, this program maybe inaccurate. Consult a hydraulics engineer. This program is for single pump sytems with a single body of water. Results: Your TDH Calculation Suggested Minimum Pipe Sizas: Flow Rate: 95.00 Gal/Min Branch Piping: 3.0 In Your Head Loss: 25.70 Ft Inlet Piping: 2.5 In Maximum Flow Rate Discharge Piping: 2.5 In at Maximum RPM: 95.00 GaliMin Ensure the drain cover max now rating is not exceeded. Head Loss at Maximum Flow Rate: 25.70 Ft 50 40 30 20 10 0 System Head Prossuro Curve 21hp, E+, Single Speed (548025) clean System tZ Desired Operation Point 0 Selected Components Components 50 Fa,r 0 Noma Haausi. 5'9we IWAON Oton IIMln Ya20. M.N0aa yvalve I. 3N Imh Near a 2.0 Piping as larsdu!ge Hutl UasN Name QArMN i a fly 95.00 OaIMN wehpe aa" 0 1. 0,32 4scemaebe 0 a am Tes Ti 0 7 Im Pumps N.m. reathy 24p. a,, aa.$e" i3rW25i 1 µPeM.rtese"Mentlb0a maaar V near, Ile IMeIF 'MMNLanxre is'n m,IMara'AlkamreeMtlseSeNo- ArtpA"Assume.sca'aiemedJ"e. sae PA.as'e. as"NUi mean a ea. N a, U0n,eA. aaia e1 .iAre.%AbetIMkaW,ae Asnemacaa.. &so.acP.A Irae u,As IM1b, is' ne'aiss droias, MiGIMYMa 'a"Ar"nenl Oafs MeowM affia. aaMWe'eviliaPMf--...* Seams1'AdA.AMdM. mryMIM M1ir,.'A Mlpiaaaab ` s..Aes, pediea. e,".I ea aev auilyinyFoavp NlpM1VUMeeM»Mcse, PaM.NIeNnNe IM IiDblm dmae Yaa'fioaddmWNNwtlINNHM4ce. PMm:MMM..IropMwme,m+ara/. REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY SOCC - ANCHOR WITH 18 SOLD COPPER _ BOND WIRE WITH APPROVED CLAMPS 18 MUD COPPER BOND WIRE WT 11 APPROVED CVMPS NICHE1-18 SOLD BARE COPPER 18"MIN-24"MAX CONT. PERIMETER BOND N EN ae IRE WTfH APPROVED 4" i0 r BELOW \ Rn])[i p p [� II SUB -GRADE SUB -GRADE BOND TO r ENTIRE EQUIPMENT ALL-INGROUNO cc 21111M ....,.. �- MOE � C : IMN uere,h,,,,,.,l na.,. 11I 1-18 SOLD BARE COPPER BOND WIRE WIIN APPROVED CLAMPS 0 (4) SIDES OF GONE MOB BOND TO POOL SUL ELECTRICAL DETAIL NOTE: ALL ELECTRICAL WORK BRAT] CONFORM TO N.R.C. 2017 SEC. 680 EQUIPOTENTIAL BONDING DETAIL PER FLORIDA BUILDING CODE ADAPTION OF THE N.E.C. 2017 SEC. 680.26