HomeMy WebLinkAboutPOOL PLANSPOOL -BOND PB-2008
WATER
ELECTRICAL DIAGRAM AND ELECTRICAL DIAGRAM N.T.S.
GFI OUTLET PER 2014 NEC
HEAT PUMP WITH JANDY TRUE
(3) #6 CU & (1) #10 CLEAR SALT MANUAL MOTOR STARTER
CU GROUND IN 1" I / SWITCH
DECK
(1) #5 REBAR
OR (2) # 3 REBAR
0
8"
NO SCALE
GRID
LOCATION OF
WATER BOND
CONDUIT \ 1HP VARIABLE SPEED JANDY
i, PUMP MOTOR WITH BUILT-IN
POOL PANEL WI 80 AMP OVERLOAD SWITCH Wl3- #10 THHN
BRKR & (2)-#4 & (2) #10 GND CU WITHIN %" MIN. CONDUIT (GFCI
THHN CU IN 1" RPVC CONDUIT PROTECTED)
S.P.S.T. TOGGLE SWITCH
(2) POOL LIGHTS
(GFI NOT REQUIRED) /
JUNCTION BOX
PUMP1PUMP
BONDED BACK TO
POOL
TIME CLOCK
W. P. DISCONNECT
12 VOLT TRANSFORMER
ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. ELECTRICAL CONTRACTOR TO
ERIFY ADEQUATE CAPACITY AT POINT OF CONNECTION
3412 THHN CU WITHIN %" MIN. CONDUIT FOR POOL LIGHT(S)
GROUND ALL BOXES, LIGHTS, MOTORS, ETC. w/#8 SOLID, BARE COPPER.
PROVIDE W.P.G.F.I. OUTLET 10' MIN. -20' MAX. FROM WATER'S EDGE.
ALL POOL PUMPS TO BE GFCI PROTECTED PER NEC 680.22(B)
IPMENT LAYOUT N.T.S.
1.5" VACUUM LINE
2X" POOL MAIN DRAIN
2" SKIMMER LINE
2" POOL RETURN LINE TO FIRST TEE, 1.5" TO POOL
JANDY TRUE CLEAR SALT SYSTEM
1.5" TO WASTE OR DISCHARGE TO GROUND
1HP JANDY VARIABLE FHPM PUMP WITH W/APPR HAIR AND LINT STRAINER
CARTRIDGE FILTER W/ PRESSURE GAUGE AND AIR RELIEF VALVE
INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP
ROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SQ. IN SURFACE AREA
(POSED TO WATER) PER MFGR'S SPECS (FIELD VERIFY LOCATION)
HEAT PUMP W/INTERNAL BY-PASS
VALVES
wa,..",yna.�weunenmV4Blao. 64018XXV
Ntlpryl of pLAE�1i198 +rvi A5MEP11259Ea]WB as4efin¢d f �'
T dSCMIer I. uE NN6M T Cmifietlb(IavbwfierslzMnlw45,N4
SI6E mqN XYfrvay Sv=tm.&e�.G9]IISA]9.
U.. Mrxa OT.,®mrnrOmw
a vN 'M-avWvaFbaYv�vm
•y.eM.rs-rwswsY .'Ys 4 _ _
_ ✓�r��•v--"F• �� 'aa oiY,.wWW,�.fa mw
__ MP
C r AHM 4 ib d m 55I5
wvav rvaamnwA
CHILD SAFETY
I BARRIER FENCE NO
CLOSER THAN 20"
FROM WATERLINE
*LOCATION OF GFI
RECEPTACLE
EQ
TO BE DETERMINED IN
FIELD PER NEC 680
QUIPMENI
VERIFY
PAD
EXACT
PER FBC
LOCATION IN
R4501.22
FIELD WITH
SUPERVISOR
POOL DETAILRESIDENTIAL
APPROVED
AND THE ANSUAPSP-72D06 FOR SUCTION
ENTRAPMENT AVOIDANCE
I
APPROVEDMAIN➢RAIN FRAMES
AND GRATES PER V.G.& ASA
ANSI 112.19.&20a/
MINIMUM Q SUCTION LINES PER PUMP 3_FT_.
SEPARATION OR SEPARATE PLANES
3 FT. MIN.
•2.5" LINE TO FIRST TEE.
1.5" TO POOL
•A
• •
3" SUCTION LINE MAX
181 G.P.M. TO FILTRATION PUMP 6 FPS MAX
Is- MIN.
( ENTIRE PERIMETERI)e-
W.L.
BOND WIRE Wl
APPR. CLAMPS
(ONE ON EACH
SIDE OF POOL 4
PER N.E.C. 2014 SEC. 680.26
(WHERE ADOPTED)
M a, .
1 ALL STEPS AND SWIMOUT BENCH
EDGES WILL HAVE 2X6 CAPTILE
BORDER OF OPPOSITE COLOR OF
GEM FINISH FOR VISIBILITY
2. HAND HOLD TO BE INSTALLED AT
ARE WHERE DECK RAISED -6" <
ABOVEPOOL
48" MAX
WATER. FIr M
DEPTH MA
Y
. .
Y
N.T.S.
PLUMBING LINES FROM
SUMP W13" TEE
-� I(
8 GAUGE SOLID COPPER WIRE
1 I 1 I
MINIMUM Is- MAX 7A" FROM
EDGE OF POOL AROUND
ENTIRE POOL PERIMETER
BURIED 4" TO 6" DEEP
#8GROUND
WIRE
STEPDETAIL
1. TREAD IS MIN. OF 10" WIDE.
2. RISER NOT GREATER THAN 12"
EXCEPT IF MORE THAN (3) TREADS
ARE USED.
3. ALL STEPS TO BE SOLID GUNITE
4000 PSI.
OUTSIDE ANGLE OF REPOSE
6' AND FURTHER = e THICK WALLS W1#3 REBAR @ 12" O.C. EACH WAY
3' TO V - 6" THICK WALLS W1#3 REBAR @ 12" O.C. EACH WAY
0' TO Y = 8" THICK WALLS W1#3 REBAR @ 12" O.C. EACH WAY
9ft
m
m 3 fl.
/
/ 0
/ c a°
/ � o
EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE
PROVIDED:
SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE
SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT
' NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES
' COMPACTION TEST OF THE BACKFILLED MARTIAL ARE PROVIDED
AT C.O. OF THE SWIMMING POOL
1
SWIMOUTS
WHEN PROVIDED SHALL
BE AT 20" MAX. BELOW
THE WATERLINE
201' max.
Per F.R.C. 4501.18 AND ANSI/
NSPI-5-2003
_SCHEMATIC MUST HOLD
y355PSI FOR
(NO SCALE) __aEAST ST 30 N
RETURN LINE
SEPARATE
AINS 36"
'PRfSSU
FILTER GAU
HAIR & LIN'
CATCHER
10NENT OF
PUMP 1
Janay Pro Series VS Repro Series Pump
VS-FHP2.0 Performance Curves
IN 43
90 39
so 3s
10 30 0
3 a
a
. 60 28
a
so zz v
y j N
E 4o 17
S MIArI
30 13 A
20 e
10 4
NO Pm
0 1
0
0 10 20 30 40 60 60 70 80 90 100 110 IM IN 140 IN 160 170 IN INFlow Rate, Gallons Per Minute. IGPMI
200
EQ. LAYOUT
(NO SCALE)
EQUIPMENT
PAD 30"MIN. CLEARANCE
PER FBC IN FRONT
R4501.22 )F SUBPANEL
LOCATION OF GFI
U RECEPTACLE
TOBE DETERMINED IN
SALT MELD PER NEC 680
VERIFY
FILTER EXACT
LOCATION IN
FIELD WITH
HEATER SUPERVISOR
• APPROVED WITH THE 2017 FLORIDA BUILDING CODE
FOR RESIDENTIAL 6TH EDITION
SPECIFICATIONS
MAX. WIDTH 28' MAX. LENGTH 40'
MIN. DEPTH 3.5' MAX. DEPTH 6'
SHAPE CUST ELEVATION T.B.D
FILL FROM EXCAVATION STOCKPILE
TILE INTERIOR FINISH GEM FILTER CS200
PUMP MAKE PER FBC 4601.20
PUMP HP: POOL FLOPRO VAR 2hp SPA NA
FILTRATION PUMP COMPLIANT WITH ANSI1APSP/ICC-1S 2011
LIGHTS POOL 2 CLR LED SPA NA
TRNFORM: POOL 100 WATT SPA NA
MAIN DRAIN: POOL 2 SPA NA
SKIMMER
(1)
_
RETURNS: POOL 3 SPA NA
JETS: POOL NA_ SPA NA
VALVED VAC LINE INCL FILL LINE NA
DISCHARGE LINE TO GROUND
CHLORINATOR TRU CLEAR SALT SYSTEM
LADDER NA
DIVING BOARD NA SLIDE NA
HEATER RHE_EM8460
VACUUM HEAD INCL POLE INCL
VACUUM HOSE INCL BRUSH INCL
LEAF SKIMMER INCL TEST KIT INCL
TREE / STUMP REMOVAL NA
CHILD BARRIER FENCE INCL.
SCREEN NA
HANDRAIL NA
ELECTRICAL INCL
POOL PATIO CONCRETE FLOCRETE
EXISTING PATIO NA
DECK DRAIN NA
GALLON CAPACITY -POOL 31,266 GAL.
GALLON CAPACITY SPA- NA GAL. NA
TURN -OVER RATE 6 hm
TERMITE TREAT INC BARRIER INCL
MAX. WATER VELOCITY - 6 WS FROM TRUNK LINES
TO 8 k./S SUCTION LINES IMPS MAX RETURN LINE
SKIMMER MIN. FLOW 25 GPM
SURFACE AREA OF POOL —880 SO. FT 136 LN FT
ESPINAL NAVION DRIVE
JOB NAME: TREASURE COAST
ADDRESS: AIRPARK LOT 99
PERMIT NO.:
DATE DRAWN: MARCH 27, 2019
DRAWN BY: DAVE CURLAND
DESIGNER APPROVAL:
CUSTOMER APPROVAL:
SCALE: 1/4" = V RAY REINHARD
PE # 47041
1010 EASTER LILLY LANE
UNIT 203 VERO BEACH 3296CD
CD
CONCRETE
P:�PPOOLS, INC.
ICRETE DECK
POOL PATIO NOTE: REMOVE GRATE & DECK-1 1 ROW OF WATERLINE TILE
WATER LEVEL WELL POINT PLUG FROM MAIN OVERPOUR BEND INTO D CK @ 48" O.C. MAX.
- DRAIN &ATTACH AUX. PUMP (IH
NE WHEN EMPTYING POO O . WATERLINE
A4'/:" THICK
_ FROM 6"X64" SLAB R w
LIGH
00 POWER 2500 FIBE v/Ai_Ls
1" LIGHT #3 STEEL @ 12" O/C E.W. 6'
Z SUPPLY GRATE SHALL TYPICAL WALL SHALL
CONDUIT BE SECURED IN /2" TYP. FLOOR SLID N0
uNDERWATE UNDERWATER WALL SECTION & FLOOR9 LOPES SHALL BE 6"THICK SLOPE
r
PLACE SOWELL POINT FLOOR
UNIFORM AND
NO c zrA: r_
LIGHT LIG__HTDE7AIL THAT TOOLS1 cGMPLYwninncLEssc.1NICHE \ NvscALE/ THAN'11( ) ARE REQUIRED HRU 6.6NO SCALEAPPROVED FOR R MOVALSTEEL-TEX FORM CYCOLAC MAIN DRAIN -A
GROUND CLAMP 6'R KRAFT WALLTHE SL(PE OF THE FLOOR FROM 3FLTHEWALLOW END WALL
#3 @ 12" O.C.B.W.TOWARG THE DEEP AREA SMALL
CONTINUOUS BOND WIRE THREADENOTE: FOR DEPTHS NorEE EF01FOOTiN7FOOCOMMON TO POOL STEEL, PLUG EATER THAN T ADD 1-
POOL FINISH RAILS & EQUIPMENT AR @ 6" O.C.
TO PUMP—► TYPICAL SECTION THRU POOL
GRAVEL BED - -
NO SCALE)
FILE C.Y
I C 04+- c053
REVIEWED FOR
CODE COMPLIANCIL
ST. LUCIE COUNTY
BOCC
SCANNED
BY
St. Lucie County
1aou- m53