Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
ENERGY EFFICIENCY CODE
FORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT SCANNED Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY BY City, State, Zip: FT. PIERCE, FL, 1p��a�, Permit Number: Jurisdiction: St. LUCI@ County Design Location: FL, FortPierceCounty: St. Lucie (Florida Climate Zone 2) 1. New construction or existing New (From Plans) 9. Wall Types (1432.0 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1224.00 ft2 b. Frame - Wood, Adjacent R=11.0 208.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? Yes 10. Ceiling Types (1753.0 sqft.) Insulation Area a. Under Attic (Vented) R=30.0 1753.00 ft2 6. Conditioned floor area above grade (ft2) 1753 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c' 11. Ducts R ft2 7. Windows(151.4 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Attic 6 250 a. U-Factor. SgI, U=0.63 111.36 ft' SHGC: SHGC=0.25 b. U-Factor: SgI, U=0.65 40.00 ft2 12. Cooling systems kBtu/hr Efficiency SHGC: SHGC=0.21 a. Central Unit 34.8 SEER:15.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Heat Pump 34.8 HSPF:8.50 SHGC: Area Weighted Average Overhang Depth: 2.850 ft. Area Weighted Average SHGC: 0.239 14. Hot water systems 8. Floor Types (1753.0 sqft.) Insulation Area a. Electric Cap: 40 gallons a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2 b. Conservation features EF: 0.970 b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.93 PASS Total Baseline Loads: 53.85 1 hereby certify that the plans and specifications covered by Review of the plans and STgTB this calculation are in compliance with the Florida Energy specifications covered by this OFTKE Code. calculation indicates compliance with the Florida Energy Code. O PREPARED By. Before construction is completed DATE t - - this building will be inspected for w O a ! compliance with Section 553.908 , I hereby certify that this building, as designed, is in compliance Florida Statutes. with the Florida Energy Code. SOD WE OWNE�� T. OFFICIAL: DATEVL DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 11/19/2018 3:23 PM EnergyGaugeO USA Section R405.4.1 CompliantF1LE Co PY gel of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: WYNNE THE WINDSOR IMP ,Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1753 Lot# Owner Name: Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: Yes PlatBook: Builder Name: WYNNE DEVELOPMENT Rotate Angle: 225 Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY Cross Ventilation: No County: St. Lucie Jurisdiction: Whole House Fan: No City, State, Zip: FT. PIERCE, Family Type: Single-family FL, New/Existing: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1753 14024 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER BEDROO 224 1792 No 0 1 1 Yes Yes Yes 2 WIC 63 504 No 0 1 No Yes Yes 3 MASTER BATH 56 448 No 0 1 Yes Yes Yes 4 M. BATH 61 488 No 0 1 Yes Yes Yes 5 LAUDRY 36 288 No 0 1 No Yes Yes 6 BEDROOM 2 180 1440 No 0 1 1 Yes Yes Yes 7 DINING/GREAT R 588 4704 No 2 1 Yes Yes Yes 8 KITCHEN 209 1672 Yes 0 1 Yes Yes Yes 9 BATH 50 400 No 0 1 Yes Yes Yes 10 HALL 25 200 No 0 1 No Yes Yes 11 FOYER 92 736 No 0 1 Yes Yes Yes 12 BEDROOM 3 169 1352 No 0 1 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 It 0 224 ft' — 0 1 0 2 Slab -On -Grade Edge Insulatio WIC 1 ft 0 63 ft' -_ 0 1 0 3 Slab -On -Grade Edge Insulatio MASTER BATH 8 It 0 56 ft' ___ 0 1 0 4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0 61 ft- 0 1 0 5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0 36 ft2 -_ 0 1 0 11/19/2018 3:23 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 6SIab-On-Grade Edge Insulatio 13EDROOM 2 12 It 0 too ft2 _- 0 1 0 7 Slab -On -Grade Edge Insulatio DINING/GREAT 50 ft 0 588 ft2 0 1 0 8 Slab -On -Grade Edge Insulatio KITCHEN lift 0 209 ft' ___ 0 1 0 9 Slab -On -Grade Edge Insulatio BATH 5 ft 0 50 ft' ___ 0 1 0 10SIab-On-Grade Edge Insulatio HALL 1 It 0 25 ft2 ____ 0 1 0 11Slab-On-Grade Edge Insulatio FOYER 9 it 0 92 ft2 ____ 0 1 0 12SIab-On-Grade Edge Insulatio BEDROOM 3 14 It 0 169 ft2 0 1 0 ROOF / Roof Gable Roof Solar SA Emitt Emitt Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Gable or Shed Metal 1847 ft2 292 112 Light 0.6 No 0.9 No 0 18.4 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 1753 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) MASTER BEDRO 30 Blown 224 ft' 0.1 Wood 2 Under Attic (Vented) WIC 30 Blown 63 ft2 0.1 Wood 3 Under Attic (Vented) MASTER BATH 30 Blown 56 ft2 0.1 Wood 4 Under Attic (Vented) M. BATH 30 Blown 61 ft2 0.1 Wood 5 Under Attic (Vented) LAUDRY 30 Blown 36 112 0.1 Wood 6 Under Attic (Vented) BEDROOM 2 30 Blown 180 ft2 0.1 Wood 7 Under Attic (Vented) DINING/GREAT 30 Blown 588 ft2 0.1 Wood 8 Under Attic (Vented) KITCHEN 30 Blown 209 ft2 0.1 Wood 9 Under Attic (Vented) BATH 30 Blown 50 ft2 0.1 Wood 10 Under Attic (Vented) HALL 30 Blown 25 ft2 0.1 Wood 11 Under Attic (Vented) FOYER 30 Blown 92 ft2 0.1 Wood 12 Under Attic (Vented) BEDROOM 3 30 Blown 169 ft2 0.1 Wood WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below 1 NE=>W Exterior Concrete Block - Ext InsMASTER BE 4.1 16 0 8 0 128.0 ft2 0 0 0.4 0 2 SW=>E Exterior Concrete Block - Ext InsMASTER BE 4.1 7 0 8 0 56.0 112 0 0. 0.4 0 3 NW=>S Exterior Concrete Block - Ext InsMASTER BE 4.1 14 0 8 0 112.0 ft2 0 0 0.4 0 4 NE=>W Exterior Concrete Block - Ext InsMASTER BA 4.1 8 0 8 0 64.0 ft2 0 0 0.4 0 11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT - WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo ,Space Pt 1� Ft In A,,, PAblite Fraction Ahqnr w 5 NE=>W Exterior Concrete Block - Lxt InsuM. BATH 4.1 7 0 8 0 56.0 ft' 0 0 0.4 0 6 NE=>W Exterior Concrete Block - Ext InfiffDROOM 2 4.1 12 0 8 0 96.0 ft' 0 0 0.4 0 7 SW=>E Exterior Concrete Block - Ext IndXNING/GRE 4.1 30 0 8 0 240.0 ft' 0 0 0.4 0 8 NW=>S Exterior Concrete Block - Ext IndXNlNG/GRE 4.1 20 0 8 0 160.0 ft' 0 0 0.4 0 9 SW=>E Exterior Concrete Block - Ext InsuKITCHEN 4.1 11 0 8 0 88.0 ft' 0 0 0.4 0 10 NE=>W Exterior Concrete Block - Ext Insul BATH 4.1 5 0 8 0 40.0 ft' 0 0 0.4 0 11 SE=>N Exterior Concrete Block - Ext Insul FOYER 4.1 8 0 8 0 64.0 ft' 0 0 0.4 0 12 SW=>E Exterior Concrete Block - Ext Insul FOYER 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 13 NE=>W Exterior Concrete Block - ExtinREDROOM 3 4.1 13 0 8 0 104.0 ft' 0 0 0.4 0 14 SW=>E Exterior Concrete Block - Ext InRIEDROOM 3 4.1 1 0 8 0 8.0 ft' 0 0 0.4 0 15 N=>SW Garage Frame - Wood BEDROOM 3 11 26 8 208.0 ft' 0.23 0.4 0 DOORS # Ornt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 SE=>N Insulated FOYER None .39 3 3 6 8 21.7 ft' WINDOWS Orientation shown is the entered orientation => changed to Worst Case. / Wall Overhang V # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Int Shade Screening 1 NW=>S 3 Metal Low-E Single. Yes 0.63 0.25 N 32.4 ft' 1 ft0 in 1 ft 4 in Drapes/blinds Exterior 5 2 NE=>W 5 Metal Low-E Single Yes 0.63 0.25 N 6.9 ft' 1 ft0 in 1 ft4 in None None 3 NE=>W 6 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft0 in 1 ft4 in None None 4 SW=>E 7 Metal Low-E Single Yes 0.63 0.25 N 39.8 ft' 1 ft0 in 1 ft4 in None None 5 NW=>S 8 Metal Low-E Single Yes 0.65 0.21 N 40.0 ft' 8 ft 0 in 1 ft 4 in None None 6 NE=>W 13 Metal Low-E Single Yes 0.63 0.25 N 16.2 ft' 1 ft 0 in 1 it 4 in Drapes/blinds Exterior 5 GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 806 ft2 806 ft' 26 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH50 1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82 168.92 .2578 7 11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Heat Pump/ Split HSPF:8.5 34.8 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 15 34.8 kBtu/hr cfrn 0.85 1 sys#1 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.97 40 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 —# DUCTS FV Supply ---- -- Return — Air CFM 25 CFM25 HVAC # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 250 ft' Attic 75 ft' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programablree Thermostat: Y Ceiling Fans: Cooling Venting Jlan Feb ]] Marr H Feb ki Mar € ju [[ �X� nAu [[ ]] r Oct Nov � Dec rIX,I [ ]Jan Apr May, Jun [X� Jul Aug [X] Sep Nov [ ] Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 SO 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 Ibs/sq.ft. 0 ft2 0 ft 0.3 MASTER BEDROO Default(8 lbs/sq.ft. ft2 ft 0.3 WIC Default(8 Ibs/sq.ft. ft2 ft 0.3 MASTER BATH Default(8 lbs/sq.ft. ft2 ft 0.3 M. BATH Default(8 lbs/sq.ft. ft2 ft 0.3 LAUDRY Default(8 Ibs/sq.ft. ft2 ft 0.3 -BEDROOM 2 Default(8 lbs/sq.ft. ft2 ft 0.3 DINING/GREAT R Default(81bs/sq.ft. ft2 ft 0.3 KITCHEN Default(8 lbs/sq.ft. ft2 ft 0.3 BATH Default(8 lbs/sq.ft. ft2 ft 0.3 HALL Default(8 lbs/sq.ft. ft2 ft 0.3 FOYER Default 8 Ibs/s .ft. ft2 ft 0.3 BEDROOM 3 Name: Test Rater Signature: Rating Compant: Test Rater Date: ��- 11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY City, State, Zip: FT. PIERCE, FL, Permit Number: Y U Owner: Jurisdiction: w x Design Location: FL, Fort Pierce � COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier. not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in any ceiling/soffit dropped ceilin9 the insulation and any gaps in the air barrier shall be sealed. air shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed. with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be cut to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind pipino and wirino Shower/tub I The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electrical/phone box o I The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots ( HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be sprinklers sealed in a manner that is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids h.�..n fi,. s�rinkler cover plates and Wall !no a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400. 1Ill 9/2018 3:23 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 98 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 34.8 a) Split system SEER 15.0 5. Is this a worst case? (yes/no) 5. Yes b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1753 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.635 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239 c) Area 7c. 151.4 8. Skylights a) U-factor:(weighted average) 8a. NA b) Solar Heat Gain Coefficient (SHGC) 8b. NA 9. Floor type, insulation level: a) Slab -on -grade (R-value) b) Wood, raised (R-value) c) Concrete, raised (R-value) 10. Wall type and insulation: A. Exterior: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) B. Adjacent: 1. Wood frame (Insulation R-value) 2. Masonry (Insulation R-value) 11. Ceiling type and insulation level a) Under attic b) Single assembly c) Knee walls/skylight walls d) Radiant barrier installed 10A1. 10A2. 4.1 14. Heating system: Capacity 34.8 a) Split system heat pump HSPF 8.5 b) Single package heat pump HSPF c) Electric resistance COP d) Gas furnace, natural gas AFUE e) Gas furnace, LPG AFUE f) Other 15. Water heating system a) Electric resistance EF 0.97 b) Gas fired, natural gas EF c) Gas fired, LPG EF d) Solar system with tank EF e) Dedicated heat pump with tank EF f) Heat recovery unit HeatRec% g) Other 10131. 11.0 10B2. 16. HVAC credits claimed (Performance Method) a) Ceiling fans 11 a. 30.0 b) Cross ventilation No 11 b. c) Whole house fan No 11c. d) Multizone cooling credit 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed based on installed code compliant features. I y Builder Signature: Date: �1 � Address of New Home: THE WINDSOR City/FL Zip: FT. PIERCE, FL 3 y CI AU M2e t 11/19/2018 3:23:44 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 + wrightsoft= Project Summary Entire House QUICK CALCS,,INC. Job: SCANNED Date: BY By: St. Lucie County For. WYNNE DEVELOPMENT, THEWINDSOR, FT. PIERCE, FL Notes., Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside.db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Structure 18467 Btuh Ducts 6190 Btuh Central vent (0 cfm) 0 Btuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24657 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Hea1753 lin Co 1753 Area ft z Volume (ft3) 14741 14741 Air changesthour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Model 25HBC536MO30 AHRI ref 7914585 Efficiency Heating input Heating output Temperature rise Actual airflow Air flow factor Static pressure Space thermostat Capacity balance point = 34 OF Backup: 8.5 HSPF 34600 Btuh @ 47OF 27 OF 1160 cfm 0.047 cfm/Btuh 0.50 in H2O Input = 7 kW, Output = 23009 Btuh, 100 AFUE Sensible Cooling Equipment Load Sizing Structure 17655 Btuh Ducts 9340 Btuh Central vent (0 cfm) 0 Btuh (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 25645 Btuh Latent Cooling Equipment Load Sizing Structure 2453 Btuh Ducts 2554 Btuh Central vent (0 cfm) 0 Btuh (none) Equipment latent load 5007 Btuh Equipment total load 30652 Btuh Req. total capacity at 0.70 SHR 3.1 ton Cooling Equipment Summary Make Carrier Trade CARRIER AIR CONDITIONING Cond 25HBC536A*030 Coil FX4DN(B,F)037 AHRtref 7914585 Efficiency 12.0 EER, 15 SEER Sensible cooling 24360 Btuh Latent cooling 10440 Btuh Total cooling 34800 Btuh Actual air flow 1160 cfm Air flow factor 0.043 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.84 Calculations approved byACCA to meet all requirements of Manual J 8th Ed AL + wrighisoft' 2017-Apr-1017:19:28 RightSuite® Universal 201717.0.14 RSU08101 �� ...k CalcsXD0cumentslWYMJE-THE WINDSOR-REVISED.mp Gale = W8 Front Door faces: N Page 1 wright ofe Right-JO Worksheet Job: Entire House Date: QUICK CALCS, INC. By. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-0666799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM 1 Room name Entire House -- - - - MASTER BEDROOM 2 . E)pwed wall 153.0 It = 45.0 It 3 Room height 8.4 It d 8.0 It heal/cod 4. Room dimensions - 1.0 x 280.0 It 5 Room area 1753.0 ft2 280.0 ft2 Ty Construction U-value Or HTM Area (ft2) Load Area - (ft2) Load - .. .number - (BtuWWF) (Btuh/ft2) a -perimeter-(ft)... (Btuh). - or perimeter (ft)... (Btuh) Heat Owl Gross WP/S Heat Cool Gross WP/S Heat Cod 6 13A4ocs _ 0143 n6 400 255 488 448 1795 1141 192 192 769 48& yAclonr ] 270 ne 35.55 7043 7 ' 0 =_247 488 0 : 0 = 0 -d ;tActom., 2 ` r4270 ne a3556 -70.43 46 a 0 S87 1151 �, - .1Actorn' - '1.270 ..n6 '3556 `45:24 i6 - 0.. . 581 739 .0 0 -0 11 ly 13AAocs 0.143 as -4.00 255 64 41 165 105 0 0 0 ( UDO 0390 se 1092 11.31 23 23 248 257 0 0 0 I yy 13A4ocs . ' —0.143 'SW - 4.00 .. 255 437 .396 ' ' -16M -- 1007 -56 56 . - 224 t 14& 0.770 , sw. 21.56 >'. 27.53 . 411 . '. 45 • .. 893 � 1140 - ', :.0 . 0 ._..- 0 ..... --. o 13A4dcs 0.143 rw 4.00 255 290 217 867 551 112 79 318 2D2 1Aclom 1.270 my 35.56. 45.24 33 0 1162 1478 33 0 1162 1478 4A5-2=d 0770 my 2156 36.90 41 0 880 1505 0 0 0 0 12Casw 0091 -+f;'255 '-" 1128. 3087.(. ;308 ,'.. ,_... 784 •i 1, 395•.p ':,' D•:' 0' =:ti0 C 16A-30md 0.032 - 0.90 232 1753 - 1763 1671 4067 - 280 280 251 65D .r 22A4p1 ". -,... ' :. -0.989 -. -. . Z7.69 " - 0.00 1753'_ . 153 . _ . `.:4237 " ::0 , . ` : 280 :.: 45 '• 1746 . - (. }':+0 61 c)AED exursion 1 1360 600 Emelope loss/gain 15564 15385 39rm 3561 12 a) hlfittr40on 2873 810 809 228 A Roomvemilation 0 0 0 0 13 kitemal gains: Occupants @ 230 2 460 0 0 Appliances/other low 0 Subtotal Qines 6 to 13) 18467 17655 4779 3789 Less edemalload 0 0 -0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 18467 17655 4779 3789 1151 Duct loads 1 345/6 53%1 6190 9340 34%a 53% 1602 20D5 - Total mom load I 1 1 24657 26995 6380 5794 Air required(cfm) 1160 ' 1160 300 249 Aft 412 wrightsoTY Right-SuBe® Universal 201717.0.14 RSU08101 ... k CalcslDocuments%WYNNE•THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N 2017-Apr-10 17:19:28 Page 1 i wrightsoft• RighW@ Worksheet Entire House QUICK CALCS, INC. 317 ST. LUCIE UL, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@IOLCOM Job: Date: By: 1 Room name WIC M. BATH 2 F5posed wall 0 ft 7.0 ft 3 Room height 8.0 ft heat/cool 8.0 ft heatfood 4 Room dimensions 7.0 x 9.0 ft 1.0 x 61.0 ft 5 Room area 63.0 ft- 61.0 ft- Ty Construction U-value Or HTM Area Load number (Bluh(fWF) (BtuWft') or perimeter (ft) (Muh) or perimeter (ft) (Btuh) Heat Cod Gross I WP/S Heat Cod Gmss WP/S Heat Cod 8 lAr 13AAocs -1 0143 ne 410 255 0 0 0 0 66 49 196 125 �1Xcicm 1270 ne 3556 .-.70.43. 0 0 . 0 .0 7' 0 . - 247 k 488 1A-croon - ..-1270 ne-....3556 .70.43. 0 0'_ --0.. 0 0 0"- 0>-; .'.0 1Ac1am: _ 1.270 _ ne 35.66 "45.24 '. 6 0 0 . 0 0 0 - 0 '0 11 W 13A4acs o 143 se a 00 266 0 0 . 0 0 0 0- 0 p L— D 11DO 0390 se 1092 11.31 0 0 0 0 0 0 0 0 ^.,0.1,lV x 400 ' .. 255 . , .:0 ., . 0 -' : ' .0 `. .0 0 -0 - - 0 4AS2om sw.: 21:56 ,27.53 - 0 0: .. - 0 "0 0 ..0 ' 10 "....0 '0 I—G 13AA= 0.143 nw 4.00 255 0 0 0 0 0 0 ,_, 0 0 1Aclom 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 �G 4As4omd 0.770 " nw , 21.55 36.90 0 0 0 0 0 0 0 0 P '. -i12C,0sw- ... "0.091 ".. , .., 2.55 -'--'L28 .. '0 :0 - '. .0. 0 ' -.0 _0'.= - ',,0 :.. 4 C_ 16A-Mmd 0.032 - 0.90 232 63 63 56 146 61 61 55 142 '�F - 22A-tpl _' .. . 0:989 - 27..69.". 0.00 63 "0 -0 : a - , 61 . -7, - "194 - 0 6 c)AED excursion -g -26 Envelope loss/gain 56 141 692 729 12 a) Infiltration 0 0 126 35 b) RoomvenlJation 0 0 0 0 13 Intemai gains: Occupants @ 230 0 0 0 0 Appliancestother 0 0 Subtotal 0irxs 6 to 13) 66 141 817, 764 Less eldemalload 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 55 141 817 7B 15 Duct loads 34% 53% 19 75 34% 53% 274 40a Total room load 1 75 216 1 1091 1168 Plr recluired(cfm) 4 8 51 50 Calculations approved byACCA to meet all requirements of Manual J Sth Ed wrights ft- 2017-Apr-1017.19:28 .h RlghtSuite@ Universal 2017 17.0.14 RSU08101 Page 2 ...k CelcslDocuments%WYNNE-TFEWINDSOR-RE%ASED.mp Cdc=MJB Front Doorfaces: N wrightsofC Right-M Worksheet Job: Entire House Data: QUICK CALCS, INC. By: 317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: T72466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM 1 Room name LAUDRY BEDROOM 0 ft 12.0 ft 3 Room heel height 8.0 ft heaUcool 8.0 ft heat/cool 4 Room dimensions 6.0 x 6.0 ft 15.0 x 120 It 5 Room area 36.0 ft' 180.0 ft- Ty Construction U-value Or HTM Area Load Area number (BtuNftk-F) (Btuhfft° or perimeter (ft) (Btuh) or perimeter (ft) - (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Cool 6 V13A4ocs 0143 ne 400 255 0 . 0 0 0 96 • 80 319 203 03 1 " 1A-clam 1.270 ne .`3556 , 70.43 .0 ., p p �. ,p . 0 p -:. p tAclom - 1 270 ,ne -3556 . 70.43 .0 , - 0 0 0 16 , �. 581 - 1161' tAelom - 1.270 no _35.65 45.24 - 01 6 0 0 ,0 0 () 4. c0 11 Y-D 13A-0ocs 0.143 se 4.00 2.65 0 0 0 .0 0 0 0 0 0 11DO 0390 as 1092 11.31 0 0 a 0 0 0 0 o yI . 3A-0acs "4Aszom 0143 -sw ' 490 ' 2.65 -27.53 ; 0 - o .. .0 0 ._;0 .':o - , - a r. -' •'0 �C -::: : 0.770 sw:' .21.56 `- - 0 - 0 - . o 0 ':0 , 0.- 0 vI�--G 13A4acs 0.143 my 4.D0 2.55 0 0 0 0 0 . 0 0 0 1A-clan 1.270 nw 35.56 45.24 0 0 0 0 0 0 0 0 r--G. "' 4AFY2oma 0.770 nw 21.55 36.90 0 0 0 0 0 0 0 0 P - "IM-0sw •.. 0.091''.- . 2.55 "- ' 1:28 0 - 0. - - p. 0 .. 0'.' 0 s :•' <.0 _ +-0 C 16A30mtl 0.032 - 0.90 232 36 36 32 84 180 180 161 418 F- :'' '22A-tpl _ ' - 0.989 - - 27.69 - 0.00 - 36 . a - 0' 0 180 ' .12 . 332 , -.; '. , .0 6 c)AED excursion -3 -60 Envelope lcss/gain 32 81 1394 1711 12 a) Infdtramon 0 0 216 61 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/ather 0 0 Subtotal pines 6 to 13) 132 81 1609 1772 Less ademal load 0 0 p 0 Less transfer 0 0 0 0 Redistribution 6 14 6 14 14 Subtotal 38 95 1615 1786 15 Duct loads 34% 53% 131 501 341/6 531/6 5411 945 Total roan load 51 145 2156 - 2no Air required (cfm) 2 6 101 117 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed wrighlsoft- ,��p RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:28 ...k CalcslDocuments\WYMJE-THEWINDSOR-RMSED.wp CaIc=MJ8 Front Doorfaces: N Page wrightsofr Right-JO Worksheet Job: Entire House pate: QUICK CALCS, INC. By: 317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: OUICKCALCS@AOLCOM 1 Room name DINWG/GREAT ROOM KITCHEN ed wall 50.0 ft 11.0 ft 3 Room t omheight 8.9 ft haat/cool 8.9 If heat/cod 4 Room dimensions 1.0 x 588.0 ft 19.0 x 11.0 ft 5 Room area 588.0 ft- 209.0 ft Ty Constmcticn U-value Or HTM Area Load Area number (BtuWftMF) (BtuWft2) or perimeter (ft) (Bluh) or perimeter (it) (Btuh) Heat Cool Gross WP/S Heat Cod Gross WP/S Heat Co,[ 6 13A-0acs 0.143 ne 400 2.55. 0 0 0 0 0. . *0 0 0 ,' ,1Aciam 1.270 ne• 3565 70.43 0 .0 0 0 0. -0 0 _.0 � ; Welorn - - 1.270 ' ne 3556 70.43' .. .. 0 . - 0 0. 0 0'. 0 0 0 4Aciom -' `p.270 - ne 35.56 45.24 0 0 . 0 0, _ 0 . . " 0 0 . , ' •'0 11 y! 13A.4ocs 0.143 se 4.00 Z55 0 0 0 0 0 0 0 0 �-D 11D0- 0390 se 1092 11.31 -.. 0 0 0 0 0 0 0 0 n 13A-0oo - .. -. 0.143 , sw: 4 00 , . 2.55 267 .. 226 " ..::; 903. 574 ` 98. ' 98 392 ':>'7249 '4AS-tam 0.770 r"sw 21.56 -.-27:53- 41 22 893 �: 1140 0 . .. .... .0 , -.0 1� 13A-4= " 0.143 my 4.00 2.55 178 137 549 349 .- 0 _0 0 0 0 1Actom 1.270 mw 35.56 45.24 0 0 0 0 0 0 0 0 �G 4h5-2omp 0.770 my 21.56 36.90 41 0 880 15DS 0 0 0 0 P'.'1'12"W.; ,, 0.091 .- -2.55' 1.28 0. .. 0. 0 0.:.. „116 .116-- 295 "-�148 C 16A-Wmd 0.032 _ - 0.90 Z32 588 588 527 1334 209 209 197 485 F. ,' `22A=tpl' 0.989 _ 27.0 . 0.00 5W .. 50 - 1385 : 0 209 _ 11 '- 305 ; -0 6 c)AED etxursion 7004 -64 EJnelope loss/gain 5136 5937 - 1179 818 12 a) infiltration 1000 292 220 62 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Appliance.s(other 0 1000 Subtotal Qiries 6 to 13) 6136 6679 1399 1880 Less e#errel load 0 0 0 0 less transfer 0 0 Redistribution 6 14 0 0 14 Subtotal 6142 6693 130 1880 15 Duct loads 347. 53% 2058 3541 340/. 531/6 469 995 Total room load 8200 10234 18 2Air required(cfm) 386 440 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .leeh wtrightsoR- RlghtSuite® Universal 201717.0.14 RSU08101 2017-Apr-10 17:19:28 ...k CaIcslDocumentslWYNI4E-THE WINDSO Universal 20171 Calc = U08 Front Door faces: N Page 4 ' wrightsoft. RighW@ Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST.. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: ONCKCALCS@AOLCOM 1 Room name BATH HALL 2 FVosed wall 5.0 ft 0 It 3 Room height 8.0 ft heat/cod 8.0 ft hea lcool 4 Room dimensions 10.0 x 5.0 ft 5.0 x 5.0 ft 5 Room area 50.0 ft2 25.0 W Ty Construction U-value Or HTM Area (ft2) Load Area (ft5 Load number (Btuh/WF) (Btulvft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross WPIS Heat Cool Gross WPIS Heat Cod 6 13AAccs 0143 ne 400 2.55 40 40 160 102 0 0-. 0 0 .tAclan '1270 ne :,. 3556 -70.43 0.' -0: 0 0 0- 0'. •' 0 '.0 i1Aclan .. `1270 ne -.3556 ..70.43 . 0> 0: 0 - 0 0- 0, 0. ;0 .1.270 . ne. , "35.56 , ' 45.24 0 -:. 0. 0 - _. 0„ ; 0 ' .... -0 --_,: '0 11 1y m4ocs 0.143 se 4.00 2.55 0 0 0 0 0 0 . ,0 0 0 11D0 0390 se 1092 11.31 0 0 0 0 0 0_ 0 0 -D . -..0143sw _ -400 -.. 255 '.27.53 ..-0:.... 0:` '0 ; .0 .. 0i .. 0' 0 r .. ;.0 AA5-2orn :. - ,0 770 � svi `21.56 . 0 -:: 0 - - 0 .. . 0.- 0 ' ' 0 ', 0 . ..0 .. WI--G 13A4ocs 0.143 rm/ 4.00 2.55 0 0 0 0 0 0 0 0 1Aclm 1.270 my 35M 45.24 0 0 0 0 0 0 0 0 - -='..12r 4A5-2omd 0.770 mx 21.56 36.90 _ 0 0- 0 0 0 0 0 0 P'.. osw=: - 0.091 ..2.55 , 1.28 0 0 0 . 0 0. - p . '0 - . _,0 C 16A4pl 0.032 - 0.90 232 50 50 _ 45 116 25 25 22 58 F , • •. 2'1p-tpl - ... . -. 0.989 ..-. :27.69 - 0.00 - 50 5 138 : . , 0 .. 25 p :0 . •.: 0 6 c)AED exursim -8 -2 Ermelope loss/gain 343 210 22 56 12 a) Irifi0ration 90 25 p . 0 b) Rcemventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 0 Subtotal Qines 6 to 13) 433 235 22 56 Less eAemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 6 14 -22 -56 14 Subtotal 439 249 0 0 15 Duct loads 34% 53% 147 132 340A 530/6 0 0 Toted roan load 586 381 0 0 Air required (arm) 28 is 0 0 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed gyp- wrightsofY 2017-Apr-1017:19:28 Aem Right -Suite® Universal 201717.0.14 RSU08101 Page 5 ...I( Ca1cslDocuments1WYNNE-THE WINDSOR-REVISED.mp Cato =MJ8 Front Door faces: N wrightsoft- RighW@ Worksheet Job: Entire House Date: QUICK CALCS, INC. Bv: 317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 7-,246"799 Fax 772-46"796 Email: OUICKCALCSa( )AOL.COM 1 Room name FOYER BEDROOM 2 E-yosed wall 9.0 ft 14.0 ft 3 Room height 8.0 k heaticod 8.0 ft heat/cod 4 Room dimensions 1.0 x 920 ft 13.0 x 13.0 ft 5 Room area 920 ft' 169.0 ft, Ty Construction U-value Or HTM Area Lead Am (ftq Load number I (Btuwft-° (Btuh/ftl o pemneter (ft) (Btuh) or perimeter ft Heat Cool Gross N/P!S Heat Cool Gross WP/S Heal Cod 6 1MA. 0143 no 4OD 255 0 0 0 0 104 88 351 223 JAc1crn .1 270 , ne .. 35,% 70.43 0 0 0 0 - 0 0 0 ' 0 1Ac1orn _ •� 1.270 ne. `ne: =. 3556 70.43 0 a 0 0 .'g. . 0 _ .'..0 11 W lAcldm ; 13A-0acs 1270 0143 se _�3556 400 ..:45.24' 255 0' 64 0.`. 0 0. i6 ,0-- 0: 581 •1739 41 165 105 0 0 0 0 --D yI 11DO "IMAces-: 0.390 -.0143 se sw 10.92 ::--,400 11.31 `._, 2.55 23 8 23 ,. : 8 248 32 257 0 0 -8 0 0 ' ,tiu. ` U-G 4A5Zorn '- _ - 0.770 sw 27.53 .. 0 , 0 ¢ - 0 20' . _ .0 .., 8 0 ,0 - 32 . 0 .20 , .:q) WI--G ocs 13A4 0.143 nw 4.OD 2.55 0 0 0 0 0 0 0 0 1Aclom 1.270 rw 35.56 45.24 0 0 0 0 0 0 0 0 �-G. 4A5-2omd 0.770 my 21.66 36.90 0 0 0 0 0 0 0 0 P .=i';12COswr -. -0091'. "2.55 `:1t28. -�88 88. ''224: .'113 -104 r. 104'. 265 -'-133 C i6A-30md -. 0032 0.90 Z32 92 92 82 213 169 169 151 392 F ' M3 tpl - 0.989 - - 27.69 : 0.00 -: .. 92 - 9 249 - • ' 0 - 169 ` 14 % '388 ?. : ' 0 ,-52 6 c)AED excursion 25. Envelops IossWn 1002 684 1 1768 1456 12 a) InfiRretion 162 46 252 71 b) Roomventlation 0 0 '0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Appliances/other 0 0 Subtotal Aires 6 to 13) 1163 730 2020 1527 Less e)dwW load D 0 0 0 Lass transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1163 730 2020 1527 15 Dud loads 34% 53% 390 386 34% 53% 677 808 Total ream load Air required(cfm) 1553 1116 1 1 2697 2335 73 48 127 100 Calculations approved byACCA to meet all requirements of Manual J 8th Ed .eek � wrighLsOfC RlghtSuReO Universal 201717.0.14 RSU08101 2017-Apr-1017:1g:28 ...k CaloslDacumentslWlTAIE-THE WINDSOR-REVISED.mp Colo =MJB Front Door faces: N Page 6 �- wrightsoft Duct System Summary Job Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772466-6796 Email: QUICKCALCS@10LCOM eroject Intormation For. WYNNE DEVELOPMENT THE WINDSOR, FT. PIERCE, FL EXtemal static pressure Pressure losses Available static pressure Supply /. return available pressure Lowest friction rate Actual airflow Total effective length. (fEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.273 in/100ft 1160 cfm 183 ft Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (In) H x W (In) Duct Mail Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH IT 586 28 16 0.372 4.0 OxO VIFx 19.5 115.0 st1 BEDROOM C 2730 101 117 0.384 7.0 OxO VIFx 15.0 115.0 st1 BEDROOM IT 2697 127 100 0.353 6.0 0x0 VIFx 26.8 115.0 st1 DININGIGREAT ROOM c 3411 129 147 0.292 7.0 OxO VIFx 36.5 135.0 st2 DINING/GREAT ROOM-8 C 3411 129 147 0.371 7.0 OxO VIFx 19.9 115.0 st1 DINING/GREATROOM-C c 3411 129 147 0.278 7.0 OxO VIFx 44.9 135.0 st2 FOYER h 1553 73 48 0.490 4.0 OxO VIFx 7.0 -95.0 KITCHEN c 2875 88 124 0.366 6.0 Ox0 VIFx 21.8 115.0 st1 LAUDRY C 145 2 6 0.371 4.0 OxO VIFx 19.9 115.0 st1 M. BATH IT 1091 51 50 0.282 6.0 OxO VIFx 42.3 135.0 st2 MASTER BEOROOM h 3190 150 124 0.273 6.0 OxO VIFx 48.4 135.0 st2 MASTER BEDROOM -A h 3190 150 124 0.284 6.0 OxO VIFx 40.9 135.0 st2 WIG C 216 4 9 0.292 1 4.0 Ox0 VIFX 36.0 135.0 st2 Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm) (Cfm) FIR (fpm) (In) (In) Material Trunk st2 Peak AVF 612 602 0.273 780 12.0 0 x 0 VinlFlx st1 st1 Peak AVF 1087 1112 0.273 796 16.0 0 x 0 VinlFlx C + wrightsoft` S2017-Apr.1017:19:29 �� Rightuite® Universe1201717.0.14 RSU08701 ... k CaicslDocumentslWYNNE-TFE WINDSOR-REVISED.mp Calc = MJB Front Door faces: N page 1 Return Branch Detail Table Name Grille Size (in) Htg (cfm) clg (cfmp TEL (ft) Design FR Veloc (fpm) Diam (in) I H x W (n) I Stud/Joist Opening (in) Duct Mat[ Trunk rb1 Ox0 1 1160 1160 0 1 0 0 0 Ox 0 VIFx ^t wri 9 htsoft' 2017-Apr-1017.19:29 RightSuiteO Universal 2017 17.0.14 RSU08101 Page 2 �� ...k CalcslDocuments\WYNNE-THE WINDSORAWSED.mp Calc =MA Front Door faces: N