FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: WYNNE THE WINDSOR IMPACT
Builder Name: WYNNE DEVELOPMENT
SCANNED
Street: THE WINDSOR
Permit Office: ST. LUCIE COUNTY
BY
City, State, Zip: FT. PIERCE, FL,
1p��a�,
Permit Number:
Jurisdiction:
St. LUCI@ County
Design Location: FL, FortPierceCounty:
St. Lucie (Florida Climate Zone 2)
1. New construction or existing New (From Plans)
9. Wall Types (1432.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1224.00 ft2
b. Frame - Wood, Adjacent
R=11.0 208.00 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? Yes
10. Ceiling Types (1753.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1753.00 ft2
6. Conditioned floor area above grade (ft2) 1753
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c'
11. Ducts
R ft2
7. Windows(151.4 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Attic
6 250
a. U-Factor. SgI, U=0.63 111.36 ft'
SHGC: SHGC=0.25
b. U-Factor: SgI, U=0.65 40.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.21
a. Central Unit
34.8 SEER:15.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Heat Pump
34.8 HSPF:8.50
SHGC:
Area Weighted Average Overhang Depth: 2.850 ft.
Area Weighted Average SHGC: 0.239
14. Hot water systems
8. Floor Types (1753.0 sqft.) Insulation Area
a. Electric
Cap: 40 gallons
a. Slab -On -Grade Edge Insulation R=0.0 1753.00 ft2
b. Conservation features
EF: 0.970
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.086 Total Proposed Modified Loads: 52.93
PASS
Total Baseline Loads: 53.85
1 hereby certify that the plans and specifications covered by
Review of the plans and
STgTB
this calculation are in compliance with the Florida Energy
specifications covered by this
OFTKE
Code.
calculation indicates compliance
with the Florida Energy Code.
O
PREPARED By.
Before construction is completed
DATE t - -
this building will be inspected for
w
O a
!
compliance with Section 553.908
,
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
SOD WE
OWNE�� T.
OFFICIAL:
DATEVL
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
11/19/2018 3:23 PM EnergyGaugeO USA Section R405.4.1 CompliantF1LE Co PY gel of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: WYNNE THE WINDSOR IMP
,Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1753
Lot#
Owner Name:
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: Yes
PlatBook:
Builder Name: WYNNE DEVELOPMENT
Rotate Angle: 225
Street:
THE WINDSOR
Permit Office: ST. LUCIE COUNTY
Cross Ventilation: No
County:
St. Lucie
Jurisdiction:
Whole House Fan: No
City, State,
Zip:
FT. PIERCE,
Family Type: Single-family
FL,
New/Existing: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp
Heating
Design Daily Temp
V Design Location TMY Site
97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39
90
70
75
299
62
Low
BLOCKS
Number Name Area
Volume
1 Entire House 1753
14024
SPACES
Number Name Area
Volume Kitchen Occupants
Bedrooms
Infil ID
Finished Cooled
Heated
1 MASTER BEDROO 224
1792 No
0
1
1
Yes
Yes
Yes
2 WIC 63
504 No
0
1
No
Yes
Yes
3 MASTER BATH 56
448 No
0
1
Yes
Yes
Yes
4 M. BATH 61
488 No
0
1
Yes
Yes
Yes
5 LAUDRY 36
288 No
0
1
No
Yes
Yes
6 BEDROOM 2 180
1440 No
0
1
1
Yes
Yes
Yes
7 DINING/GREAT R 588
4704 No
2
1
Yes
Yes
Yes
8 KITCHEN 209
1672 Yes
0
1
Yes
Yes
Yes
9 BATH 50
400 No
0
1
Yes
Yes
Yes
10 HALL 25
200 No
0
1
No
Yes
Yes
11 FOYER 92
736 No
0
1
Yes
Yes
Yes
12 BEDROOM 3 169
1352 No
0
1
1
Yes
Yes
Yes
FLOORS
# Floor Type Space
Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio MASTER BEDRO 37 It 0
224 ft'
—
0 1
0
2 Slab -On -Grade Edge Insulatio WIC
1 ft 0
63 ft'
-_
0 1
0
3 Slab -On -Grade Edge Insulatio MASTER BATH 8 It 0
56 ft'
___
0 1
0
4 Slab -On -Grade Edge Insulatio M. BATH 7 ft 0
61 ft-
0 1
0
5 Slab -On -Grade Edge Insulatio LAUDRY 1 ft 0
36 ft2
-_
0 1
0
11/19/2018 3:23 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
6SIab-On-Grade Edge Insulatio
13EDROOM 2 12 It
0
too ft2
_-
0
1
0
7 Slab -On -Grade Edge Insulatio
DINING/GREAT 50 ft
0
588 ft2
0
1
0
8 Slab -On -Grade Edge Insulatio
KITCHEN lift
0
209 ft'
___
0
1
0
9 Slab -On -Grade Edge Insulatio
BATH 5 ft
0
50 ft'
___
0
1
0
10SIab-On-Grade Edge Insulatio
HALL 1 It
0
25 ft2
____
0
1
0
11Slab-On-Grade Edge Insulatio
FOYER 9 it
0
92 ft2
____
0
1
0
12SIab-On-Grade Edge Insulatio
BEDROOM 3 14 It
0
169 ft2
0
1
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emitt
Deck
Pitch
V
# Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1 Gable or Shed
Metal 1847 ft2
292 112
Light
0.6
No
0.9
No
0
18.4
ATTIC
/
V
# Type
Ventilation Vent Ratio (1 in)
Area
RBS
IRCC
1 Full attic
Vented
150
1753 ft2
N
N
CEILING
# Ceiling Type
Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1 Under Attic (Vented)
MASTER BEDRO
30
Blown
224 ft'
0.1
Wood
2 Under Attic (Vented)
WIC
30
Blown
63 ft2
0.1
Wood
3 Under Attic (Vented)
MASTER BATH
30
Blown
56 ft2
0.1
Wood
4 Under Attic (Vented)
M. BATH
30
Blown
61 ft2
0.1
Wood
5 Under Attic (Vented)
LAUDRY
30
Blown
36 112
0.1
Wood
6 Under Attic (Vented)
BEDROOM 2
30
Blown
180 ft2
0.1
Wood
7 Under Attic (Vented)
DINING/GREAT
30
Blown
588 ft2
0.1
Wood
8 Under Attic (Vented)
KITCHEN
30
Blown
209 ft2
0.1
Wood
9 Under Attic (Vented)
BATH
30
Blown
50 ft2
0.1
Wood
10 Under Attic (Vented)
HALL
30
Blown
25 ft2
0.1
Wood
11 Under Attic (Vented)
FOYER
30
Blown
92 ft2
0.1
Wood
12 Under Attic (Vented)
BEDROOM 3
30
Blown
169 ft2
0.1
Wood
WALLS
Adjacent
Space Cavity Width
Height
Sheathing Framing
Solar
Below
1
NE=>W Exterior Concrete Block - Ext InsMASTER BE
4.1 16
0 8
0
128.0 ft2
0
0
0.4
0
2
SW=>E Exterior Concrete Block - Ext InsMASTER BE
4.1 7
0 8
0
56.0 112
0
0.
0.4
0
3
NW=>S Exterior Concrete Block - Ext InsMASTER BE
4.1 14
0 8
0
112.0 ft2
0
0
0.4
0
4
NE=>W Exterior Concrete Block - Ext InsMASTER BA
4.1 8
0 8
0
64.0 ft2
0
0
0.4
0
11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT -
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Belo
,Space
Pt
1�
Ft In
A,,,
PAblite
Fraction Ahqnr
w
5
NE=>W Exterior
Concrete Block - Lxt InsuM. BATH
4.1 7
0
8 0
56.0 ft'
0
0
0.4
0
6
NE=>W Exterior
Concrete Block - Ext InfiffDROOM 2
4.1 12
0
8 0
96.0 ft'
0
0
0.4
0
7
SW=>E Exterior
Concrete Block - Ext IndXNING/GRE
4.1 30
0
8 0
240.0 ft'
0
0
0.4
0
8
NW=>S Exterior
Concrete Block - Ext IndXNlNG/GRE
4.1 20
0
8 0
160.0 ft'
0
0
0.4
0
9
SW=>E Exterior
Concrete Block - Ext InsuKITCHEN
4.1 11
0
8 0
88.0 ft'
0
0
0.4
0
10
NE=>W Exterior
Concrete Block - Ext Insul BATH
4.1 5
0
8 0
40.0 ft'
0
0
0.4
0
11
SE=>N Exterior
Concrete Block - Ext Insul FOYER
4.1 8
0
8 0
64.0 ft'
0
0
0.4
0
12
SW=>E Exterior
Concrete Block - Ext Insul FOYER
4.1 1
0
8 0
8.0 ft'
0
0
0.4
0
13
NE=>W Exterior
Concrete Block - ExtinREDROOM 3
4.1 13
0
8 0
104.0 ft'
0
0
0.4
0
14
SW=>E Exterior
Concrete Block - Ext InRIEDROOM 3
4.1 1
0
8 0
8.0 ft'
0
0
0.4
0
15
N=>SW Garage
Frame - Wood BEDROOM 3
11 26
8
208.0 ft'
0.23
0.4
0
DOORS
# Ornt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft In
Ft In
1 SE=>N Insulated FOYER
None
.39
3
3
6 8
21.7 ft'
WINDOWS
Orientation shown is the entered orientation
=> changed to Worst Case.
/
Wall
Overhang
V
# Ornt ID
Frame Panes NFRC U-Factor
SHGC
Imp
Area
Depth
Separation
Int Shade
Screening
1 NW=>S 3
Metal Low-E Single. Yes
0.63 0.25
N
32.4 ft'
1 ft0 in
1 ft 4 in
Drapes/blinds
Exterior 5
2 NE=>W 5
Metal Low-E Single Yes
0.63 0.25
N
6.9 ft'
1 ft0 in
1 ft4 in
None
None
3 NE=>W 6
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft'
1 ft0 in
1 ft4 in
None
None
4 SW=>E 7
Metal Low-E Single Yes
0.63 0.25
N
39.8 ft'
1 ft0 in
1 ft4 in
None
None
5 NW=>S 8
Metal Low-E Single Yes
0.65 0.21
N
40.0 ft'
8 ft 0 in
1 ft 4 in
None
None
6 NE=>W 13
Metal Low-E Single Yes
0.63 0.25
N
16.2 ft'
1 ft 0 in
1 it 4 in
Drapes/blinds
Exterior 5
GARAGE
# Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1 806 ft2 806 ft'
26 ft
8 ft
11
INFILTRATION
# Scope Method SLA CFM 50 ELA
EgLA
ACH
ACH50
1 Wholehouse Proposed ACH(50) .000356 1636.1 89.82
168.92
.2578
7
11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Heat Pump/
Split
HSPF:8.5
34.8 kBtu/hr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency
Capacity
Air Flow
SHR
Block
Ducts
1
Central Unit/
Split
SEER: 15 34.8 kBtu/hr cfrn
0.85
1
sys#1
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Garage
0.97 40 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
—#
DUCTS
FV
Supply ----
-- Return —
Air
CFM 25
CFM25
HVAC #
Location R-Value Area
Location
Area Leakage Type
Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6 250 ft'
Attic
75 ft' Default Leakage
Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablree Thermostat: Y
Ceiling Fans:
Cooling
Venting
Jlan Feb
]] Marr
H Feb ki Mar
€
ju [[
�X�
nAu
[[ ]]
r
Oct
Nov
�
Dec
rIX,I
[ ]Jan
Apr
May, Jun [X� Jul
Aug
[X] Sep
Nov
[ ] Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6
7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78
78
78
SO
80
80
80
PM 80
80 78
78 78 78
78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78
78
78
78
78
78
78
PM 78
78 78
78 78 78
78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68
68
68
68
68
68
68
PM 68
68 68
68 68 68
68
68
68
68
66
66
11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 Ibs/sq.ft.
0 ft2
0 ft
0.3
MASTER BEDROO
Default(8 lbs/sq.ft.
ft2
ft
0.3
WIC
Default(8 Ibs/sq.ft.
ft2
ft
0.3
MASTER BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
M. BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
LAUDRY
Default(8 Ibs/sq.ft.
ft2
ft
0.3
-BEDROOM 2
Default(8 lbs/sq.ft.
ft2
ft
0.3
DINING/GREAT R
Default(81bs/sq.ft.
ft2
ft
0.3
KITCHEN
Default(8 lbs/sq.ft.
ft2
ft
0.3
BATH
Default(8 lbs/sq.ft.
ft2
ft
0.3
HALL
Default(8 lbs/sq.ft.
ft2
ft
0.3
FOYER
Default 8 Ibs/s .ft.
ft2
ft
0.3
BEDROOM 3
Name: Test Rater Signature:
Rating Compant: Test Rater Date: ��-
11/19/2018 3:23 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: WYNNE THE WINDSOR IMPACT Builder Name: WYNNE DEVELOPMENT
Street: THE WINDSOR Permit Office: ST. LUCIE COUNTY
City, State, Zip: FT. PIERCE, FL, Permit Number:
Y
U
Owner: Jurisdiction:
w
x
Design Location: FL, Fort Pierce
�
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any ceiling/soffit
dropped ceilin9
the insulation and any gaps in the air barrier shall be sealed.
air
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spaces.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind pipino and wirino
Shower/tub
I The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box o
I The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
( HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
h.�..n fi,. s�rinkler cover plates and Wall !no
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
1Ill 9/2018 3:23 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1.
New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts
R
6.0
2. Single-family or multiple -family
2.
Single-family
b) Return ducts
R
6.0
c) AHU location
Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system:
Capacity
34.8
a) Split system
SEER
15.0
5. Is this a worst case? (yes/no)
5.
Yes
b) Single package
SEER
c) Ground/water source
SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1753
d) Room unit/PTAC
EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average) 7a. 0.635
b) Solar Heat Gain Coefficient (SHGC) 7b. 0.239
c) Area 7c. 151.4
8. Skylights
a) U-factor:(weighted average) 8a. NA
b) Solar Heat Gain Coefficient (SHGC) 8b. NA
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
b) Wood, raised (R-value)
c) Concrete, raised (R-value)
10. Wall type and insulation:
A. Exterior:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
B. Adjacent:
1. Wood frame (Insulation R-value)
2. Masonry (Insulation R-value)
11. Ceiling type and insulation level
a) Under attic
b) Single assembly
c) Knee walls/skylight walls
d) Radiant barrier installed
10A1.
10A2. 4.1
14. Heating system: Capacity 34.8
a) Split system heat pump HSPF 8.5
b) Single package heat pump HSPF
c) Electric resistance COP
d) Gas furnace, natural gas AFUE
e) Gas furnace, LPG AFUE
f) Other
15. Water heating system
a) Electric resistance EF 0.97
b) Gas fired, natural gas EF
c) Gas fired, LPG EF
d) Solar system with tank EF
e) Dedicated heat pump with tank EF
f) Heat recovery unit HeatRec%
g) Other
10131. 11.0
10B2.
16. HVAC credits claimed (Performance Method)
a) Ceiling fans
11 a. 30.0
b) Cross ventilation No
11 b.
c) Whole house fan No
11c.
d) Multizone cooling credit
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features. I y
Builder Signature: Date:
�1 �
Address of New Home: THE WINDSOR City/FL Zip: FT. PIERCE, FL 3 y CI
AU M2e t
11/19/2018 3:23:44 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
+ wrightsoft=
Project Summary
Entire House
QUICK CALCS,,INC.
Job:
SCANNED Date:
BY By:
St. Lucie County
For. WYNNE DEVELOPMENT,
THEWINDSOR, FT. PIERCE, FL
Notes.,
Weather. Fort Pierce, FL, US
Winter Design Conditions Summer Design Conditions
Outside db 42 OF Outside db 90 OF
Inside db 70 OF Inside.db 75 OF
Design TD 28 OF Design TD 15 OF
Daily range L
Relative humidity 50 %
Moisture difference 61 gr/lb
Heating Summary
Structure 18467 Btuh
Ducts 6190 Btuh
Central vent (0 cfm) 0 Btuh
(none)
Humidification 0 Btuh
Piping 0 Btuh
Equipment load 24657 Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Hea1753 lin
Co 1753
Area ft z
Volume (ft3)
14741
14741
Air changesthour
0.38
0.20
Equiv. AVF (cfm)
93
49
Heating Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Model 25HBC536MO30
AHRI ref 7914585
Efficiency
Heating input
Heating output
Temperature rise
Actual airflow
Air flow factor
Static pressure
Space thermostat
Capacity balance point = 34 OF
Backup:
8.5 HSPF
34600
Btuh @ 47OF
27
OF
1160
cfm
0.047
cfm/Btuh
0.50
in H2O
Input = 7 kW, Output = 23009 Btuh, 100 AFUE
Sensible Cooling Equipment Load Sizing
Structure
17655
Btuh
Ducts
9340
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 25645 Btuh
Latent Cooling Equipment Load Sizing
Structure
2453
Btuh
Ducts
2554
Btuh
Central vent (0 cfm)
0
Btuh
(none)
Equipment latent load
5007
Btuh
Equipment total load
30652
Btuh
Req. total capacity at 0.70 SHR
3.1
ton
Cooling Equipment Summary
Make Carrier
Trade CARRIER AIR CONDITIONING
Cond 25HBC536A*030
Coil FX4DN(B,F)037
AHRtref 7914585
Efficiency 12.0 EER, 15 SEER
Sensible cooling
24360
Btuh
Latent cooling
10440
Btuh
Total cooling
34800
Btuh
Actual air flow
1160
cfm
Air flow factor
0.043
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.84
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
AL
+ wrighisoft' 2017-Apr-1017:19:28
RightSuite® Universal 201717.0.14 RSU08101
�� ...k CalcsXD0cumentslWYMJE-THE WINDSOR-REVISED.mp Gale = W8 Front Door faces: N Page 1
wright ofe Right-JO Worksheet Job:
Entire House Date:
QUICK CALCS, INC. By.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 772-0666799 Fax 772-4666796 Email: OUICKCALCS@AOL.COM
1
Room name
Entire House -- -
- - MASTER BEDROOM
2
. E)pwed wall
153.0 It =
45.0 It
3
Room height
8.4 It d
8.0 It heal/cod
4.
Room dimensions
- 1.0 x 280.0 It
5
Room area
1753.0 ft2
280.0 ft2
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area - (ft2)
Load
- ..
.number -
(BtuWWF)
(Btuh/ft2)
a -perimeter-(ft)...
(Btuh). -
or perimeter (ft)...
(Btuh)
Heat
Owl
Gross
WP/S
Heat
Cool
Gross
WP/S
Heat
Cod
6
13A4ocs _
0143
n6
400
255
488
448
1795
1141
192
192
769
48&
yAclonr
] 270
ne
35.55
7043
7
' 0
=_247
488
0
: 0
= 0
-d
;tActom., 2 `
r4270
ne
a3556
-70.43
46
a 0
S87
1151
�,
-
.1Actorn' -
'1.270
..n6
'3556
`45:24
i6
- 0..
. 581
739
.0
0
-0
11
ly
13AAocs
0.143
as
-4.00
255
64
41
165
105
0
0
0
(
UDO
0390
se
1092
11.31
23
23
248
257
0
0
0
I
yy
13A4ocs . '
—0.143
'SW
- 4.00
.. 255
437
.396
' ' -16M
-- 1007
-56
56
. - 224
t 14&
0.770
, sw.
21.56 >'.
27.53
. 411
. '. 45
•
.. 893
� 1140
-
', :.0
.
0
._..-
0
.....
--. o
13A4dcs
0.143
rw
4.00
255
290
217
867
551
112
79
318
2D2
1Aclom
1.270
my
35.56.
45.24
33
0
1162
1478
33
0
1162
1478
4A5-2=d
0770
my
2156
36.90
41
0
880
1505
0
0
0
0
12Casw
0091
-+f;'255 '-"
1128.
3087.(.
;308
,'.. ,_...
784
•i 1, 395•.p
':,'
D•:'
0'
=:ti0
C
16A-30md
0.032
-
0.90
232
1753
-
1763
1671
4067
-
280
280
251
65D
.r
22A4p1 ". -,...
' :. -0.989
-. -.
.
Z7.69 "
- 0.00
1753'_
.
153
. _
. `.:4237
"
::0
, .
` : 280
:.:
45
'•
1746
. -
(. }':+0
61
c)AED exursion
1 1360
600
Emelope loss/gain
15564
15385
39rm
3561
12
a) hlfittr40on
2873
810
809
228
A Roomvemilation
0
0
0
0
13
kitemal gains: Occupants @ 230
2
460
0
0
Appliances/other
low
0
Subtotal Qines 6 to 13)
18467
17655
4779
3789
Less edemalload
0
0
-0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
18467
17655
4779
3789
1151
Duct loads 1
345/6
53%1
6190
9340
34%a
53%
1602
20D5
-
Total mom load
I
1
1
24657
26995
6380
5794
Air required(cfm)
1160
' 1160
300
249
Aft 412 wrightsoTY Right-SuBe® Universal 201717.0.14 RSU08101
... k CalcslDocuments%WYNNE•THEWINDSOR-REVISED.mp Calc=MJ8 Front Doorfaces: N
2017-Apr-10 17:19:28
Page 1
i wrightsoft• RighW@ Worksheet
Entire House
QUICK CALCS, INC.
317 ST. LUCIE UL, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772466-6796 Email: OUICKCALCS@IOLCOM
Job:
Date:
By:
1
Room name
WIC
M. BATH
2
F5posed wall
0 ft
7.0 ft
3
Room height
8.0 ft heat/cool
8.0 ft heatfood
4
Room dimensions
7.0 x 9.0 ft
1.0 x 61.0 ft
5
Room area
63.0 ft-
61.0 ft-
Ty
Construction
U-value
Or
HTM
Area
Load
number
(Bluh(fWF)
(BtuWft')
or perimeter (ft)
(Muh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
I WP/S
Heat
Cod
Gmss
WP/S
Heat
Cod
8
lAr
13AAocs -1
0143
ne
410
255
0
0
0
0
66
49
196
125
�1Xcicm
1270
ne
3556
.-.70.43.
0
0
. 0
.0
7'
0
. - 247
k 488
1A-croon -
..-1270
ne-....3556
.70.43.
0
0'_
--0..
0
0
0"-
0>-;
.'.0
1Ac1am: _
1.270
_ ne
35.66
"45.24
'. 6
0
0
. 0
0
0
- 0
'0
11
W
13A4acs
o 143
se
a 00
266
0
0
.
0
0
0
0-
0
p
L— D
11DO
0390
se
1092
11.31
0
0
0
0
0
0
0
0
^.,0.1,lV
x 400
' .. 255
. , .:0
., . 0
-' : ' .0
`. .0
0
-0
- - 0
4AS2om
sw.:
21:56
,27.53
- 0
0:
.. - 0
"0
0
..0
' 10
"....0
'0
I—G
13AA=
0.143
nw
4.00
255
0
0
0
0
0
0
,_,
0
0
1Aclom
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
�G
4As4omd
0.770
" nw
, 21.55
36.90
0
0
0
0
0
0
0
0
P '.
-i12C,0sw- ...
"0.091
".. ,
.., 2.55
-'--'L28
.. '0
:0
- '. .0.
0
' -.0
_0'.=
- ',,0
:.. 4
C_
16A-Mmd
0.032
-
0.90
232
63
63
56
146
61
61
55
142
'�F -
22A-tpl _' .. .
0:989
-
27..69.".
0.00
63
"0
-0
: a
- , 61
. -7,
- "194
- 0
6
c)AED excursion
-g
-26
Envelope loss/gain
56
141
692
729
12
a) Infiltration
0
0
126
35
b) RoomvenlJation
0
0
0
0
13
Intemai gains: Occupants @ 230
0
0
0
0
Appliancestother
0
0
Subtotal 0irxs 6 to 13)
66
141
817,
764
Less eldemalload
0
0
0
0
Less transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
55
141
817
7B
15
Duct loads
34%
53%
19
75
34%
53%
274
40a
Total room load
1
75
216
1
1091
1168
Plr recluired(cfm)
4
8
51
50
Calculations approved byACCA to meet all requirements of Manual J Sth Ed
wrights ft- 2017-Apr-1017.19:28
.h RlghtSuite@ Universal 2017 17.0.14 RSU08101 Page 2
...k CelcslDocuments%WYNNE-TFEWINDSOR-RE%ASED.mp Cdc=MJB Front Doorfaces: N
wrightsofC Right-M Worksheet Job:
Entire House Data:
QUICK CALCS, INC. By:
317 ST. LUCIE LM, FT. PIERCE, FL 34946 Phone: T72466-6799 Fax 772466-6796 Email: OUICKCALCS@AOLCOM
1
Room name
LAUDRY
BEDROOM
0 ft
12.0 ft
3
Room heel
height
8.0 ft heaUcool
8.0 ft heat/cool
4
Room dimensions
6.0 x 6.0 ft
15.0 x 120 It
5
Room area
36.0 ft'
180.0 ft-
Ty
Construction
U-value
Or
HTM
Area
Load
Area
number
(BtuNftk-F)
(Btuhfft°
or perimeter (ft)
(Btuh)
or perimeter (ft) -
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cod
Gross
WP/S
Heat
Cool
6
V13A4ocs
0143
ne
400
255
0
. 0
0
0
96
• 80
319
203
03
1 "
1A-clam
1.270
ne
.`3556
, 70.43
.0
., p
p
�. ,p
. 0
p
-:. p
tAclom
- 1 270
,ne
-3556
. 70.43
.0
, - 0
0
0
16
, �. 581
- 1161'
tAelom -
1.270
no
_35.65
45.24
- 01
6
0
0
,0
0
()
4. c0
11
Y-D
13A-0ocs
0.143
se
4.00
2.65
0
0
0
.0
0
0
0
0
0
11DO
0390
as
1092
11.31
0
0
a
0
0
0
0
o
yI .
3A-0acs
"4Aszom
0143
-sw
' 490
' 2.65
-27.53
; 0
- o
.. .0
0
._;0
.':o
- , - a
r. -' •'0
�C
-:::
: 0.770
sw:'
.21.56
`-
- 0
- 0
- . o
0
':0
, 0.-
0
vI�--G
13A4acs
0.143
my
4.D0
2.55
0
0
0
0
0
.
0
0
0
1A-clan
1.270
nw
35.56
45.24
0
0
0
0
0
0
0
0
r--G.
"'
4AFY2oma
0.770
nw
21.55
36.90
0
0
0
0
0
0
0
0
P -
"IM-0sw •..
0.091''.-
.
2.55
"- ' 1:28
0
- 0.
- - p.
0
.. 0'.'
0
s :•' <.0
_ +-0
C
16A30mtl
0.032
-
0.90
232
36
36
32
84
180
180
161
418
F- :''
'22A-tpl _ '
- 0.989
- -
27.69
- 0.00
- 36
. a
- 0'
0
180
' .12
. 332
, -.; '. , .0
6
c)AED excursion
-3
-60
Envelope lcss/gain
32
81
1394
1711
12
a) Infdtramon
0
0
216
61
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/ather
0
0
Subtotal pines 6 to 13)
132
81
1609
1772
Less ademal load
0
0
p
0
Less transfer
0
0
0
0
Redistribution
6
14
6
14
14
Subtotal
38
95
1615
1786
15
Duct loads
34%
53%
131
501
341/6
531/6
5411
945
Total roan load
51
145
2156
- 2no
Air required (cfm)
2
6
101
117
Calculations approved bvACCA to meet all requirements of Manual J 8th Ed
wrighlsoft- ,��p RlghtSuite® Universal 2017 17.0.14 RSU08101 2017-Apr-1017:19:28
...k CalcslDocuments\WYMJE-THEWINDSOR-RMSED.wp CaIc=MJ8 Front Doorfaces: N Page
wrightsofr Right-JO Worksheet Job:
Entire House pate:
QUICK CALCS, INC. By:
317 ST. LUCIE LR, FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: OUICKCALCS@AOLCOM
1
Room name
DINWG/GREAT ROOM
KITCHEN
ed wall
50.0 ft
11.0 ft
3
Room t
omheight
8.9 ft haat/cool
8.9 If heat/cod
4
Room dimensions
1.0 x 588.0 ft
19.0 x 11.0 ft
5
Room area
588.0 ft-
209.0 ft
Ty
Constmcticn
U-value
Or
HTM
Area
Load
Area
number
(BtuWftMF)
(BtuWft2)
or perimeter (ft)
(Bluh)
or perimeter (it)
(Btuh)
Heat
Cool
Gross
WP/S
Heat
Cod
Gross
WP/S
Heat
Co,[
6
13A-0acs
0.143
ne
400
2.55.
0
0
0
0
0.
. *0
0
0
,'
,1Aciam
1.270
ne•
3565
70.43
0
.0
0
0
0.
-0
0
_.0
� ;
Welorn - -
1.270
' ne
3556
70.43'
.. .. 0
. - 0
0.
0
0'.
0
0
0
4Aciom -'
`p.270
- ne
35.56
45.24
0
0
. 0
0,
_ 0
. .
" 0
0
. , ' •'0
11
y!
13A.4ocs
0.143
se
4.00
Z55
0
0
0
0
0
0
0
0
�-D
11D0-
0390
se
1092
11.31
-..
0
0
0
0
0
0
0
0
n
13A-0oo - ..
-. 0.143
, sw:
4 00
, . 2.55
267
.. 226
" ..::; 903.
574
` 98.
' 98
392
':>'7249
'4AS-tam
0.770
r"sw
21.56
-.-27:53-
41
22
893
�: 1140
0
.
..
.... .0
,
-.0
1�
13A-4= "
0.143
my
4.00
2.55
178
137
549
349
.-
0
_0
0
0
0
1Actom
1.270
mw
35.56
45.24
0
0
0
0
0
0
0
0
�G
4h5-2omp
0.770
my
21.56
36.90
41
0
880
15DS
0
0
0
0
P'.'1'12"W.;
,,
0.091
.-
-2.55'
1.28
0.
.. 0.
0
0.:..
„116
.116--
295
"-�148
C
16A-Wmd
0.032
_ -
0.90
Z32
588
588
527
1334
209
209
197
485
F. ,'
`22A=tpl'
0.989
_
27.0
. 0.00
5W
.. 50
- 1385
: 0
209
_ 11
'- 305
; -0
6
c)AED etxursion
7004
-64
EJnelope loss/gain
5136
5937
-
1179
818
12
a) infiltration
1000
292
220
62
b) Room ventilation
0
0
0
0
13
Internal gains: Occupants @ 230
2
460
0
0
Appliance.s(other
0
1000
Subtotal Qiries 6 to 13)
6136
6679
1399
1880
Less e#errel load
0
0
0
0
less transfer
0
0
Redistribution
6
14
0
0
14
Subtotal
6142
6693
130
1880
15
Duct loads
347.
53%
2058
3541
340/.
531/6
469
995
Total room load
8200
10234
18
2Air
required(cfm)
386
440
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
.leeh wtrightsoR- RlghtSuite® Universal 201717.0.14 RSU08101 2017-Apr-10 17:19:28
...k CaIcslDocumentslWYNI4E-THE WINDSO Universal
20171 Calc = U08 Front Door faces: N
Page 4
' wrightsoft. RighW@ Worksheet Job:
Entire House Date:
By:
QUICK CALCS, INC.
317 ST.. LUCIE I.M. FT. PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-46"796 Email: ONCKCALCS@AOLCOM
1
Room name
BATH
HALL
2
FVosed wall
5.0 ft
0 It
3
Room height
8.0 ft heat/cod
8.0 ft hea lcool
4
Room dimensions
10.0 x 5.0 ft
5.0 x 5.0 ft
5
Room area
50.0 ft2
25.0 W
Ty
Construction
U-value
Or
HTM
Area (ft2)
Load
Area (ft5
Load
number
(Btuh/WF)
(Btulvft2)
or perimeter (ft)
(Btuh)
or perimeter (ft)
(Btuh)
Heat
Cod
Gross
WPIS
Heat
Cool
Gross
WPIS
Heat
Cod
6
13AAccs
0143
ne
400
2.55
40
40
160
102
0
0-.
0
0
.tAclan
'1270
ne
:,. 3556
-70.43
0.'
-0:
0
0
0-
0'.
•' 0
'.0
i1Aclan ..
`1270
ne
-.3556
..70.43
. 0>
0:
0
- 0
0-
0,
0.
;0
.1.270
. ne.
, "35.56
, ' 45.24
0
-:. 0.
0
- _. 0„
; 0
' .... -0
--_,: '0
11
1y
m4ocs
0.143
se
4.00
2.55
0
0
0
0
0
0
. ,0
0
0
11D0
0390
se
1092
11.31
0
0
0
0
0
0_
0
0
-D
. -..0143sw
_
-400
-.. 255
'.27.53
..-0:....
0:`
'0
; .0
.. 0i
.. 0'
0
r .. ;.0
AA5-2orn :.
- ,0 770
� svi
`21.56
.
0
-:: 0
- - 0
.. . 0.-
0
' ' 0
', 0
. ..0
..
WI--G
13A4ocs
0.143
rm/
4.00
2.55
0
0
0
0
0
0
0
0
1Aclm
1.270
my
35M
45.24
0
0
0
0
0
0
0
0
-
-='..12r
4A5-2omd
0.770
mx
21.56
36.90
_ 0
0-
0
0
0
0
0
0
P'..
osw=:
- 0.091
..2.55
,
1.28
0
0
0
. 0
0.
- p
. '0
- . _,0
C
16A4pl
0.032
-
0.90
232
50
50
_
45
116
25
25
22
58
F , • •.
2'1p-tpl - ...
. -. 0.989
..-.
:27.69
- 0.00
- 50
5
138
: . , 0
.. 25
p
:0
. •.: 0
6
c)AED exursim
-8
-2
Ermelope loss/gain
343
210
22
56
12
a) Irifi0ration
90
25
p
. 0
b) Rcemventilation
0
0
0
0
13
Internal gains: Occupants @ 230
0
0
0
0
Appliances/other
0
0
Subtotal Qines 6 to 13)
433
235
22
56
Less eAemal load
0
0
0
0
Less transfer
0
0
0
0
Redistribution
6
14
-22
-56
14
Subtotal
439
249
0
0
15
Duct loads
34%
53%
147
132
340A
530/6
0
0
Toted roan load
586
381
0
0
Air required (arm)
28
is
0
0
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed
gyp- wrightsofY 2017-Apr-1017:19:28
Aem Right -Suite® Universal 201717.0.14 RSU08101 Page 5
...I( Ca1cslDocuments1WYNNE-THE WINDSOR-REVISED.mp Cato =MJ8 Front Door faces: N
wrightsoft-
RighW@ Worksheet Job:
Entire House Date:
QUICK CALCS, INC.
Bv:
317 ST. LUCIE LN., FT. PIERCE, FL 34M Phone: 7-,246"799 Fax 772-46"796 Email: OUICKCALCSa( )AOL.COM
1
Room name
FOYER
BEDROOM
2
E-yosed wall
9.0 ft
14.0 ft
3
Room height
8.0 k heaticod
8.0 ft heat/cod
4
Room dimensions
1.0 x 920 ft
13.0 x 13.0 ft
5
Room area
920 ft'
169.0 ft,
Ty
Construction
U-value
Or
HTM
Area
Lead
Am (ftq
Load
number
I
(Btuwft-°
(Btuh/ftl
o pemneter (ft)
(Btuh)
or perimeter ft
Heat
Cool
Gross
N/P!S
Heat
Cool
Gross
WP/S
Heal
Cod
6
1MA.
0143
no
4OD
255
0
0
0
0
104
88
351
223
JAc1crn
.1 270
, ne
.. 35,%
70.43
0
0
0
0
- 0
0
0
' 0
1Ac1orn _
•�
1.270
ne.
`ne:
=. 3556
70.43
0
a
0
0
.'g.
.
0
_ .'..0
11
W
lAcldm ;
13A-0acs
1270
0143
se
_�3556
400
..:45.24'
255
0'
64
0.`.
0
0.
i6
,0--
0:
581
•1739
41
165
105
0
0
0
0
--D
yI
11DO
"IMAces-:
0.390
-.0143
se
sw
10.92
::--,400
11.31
`._, 2.55
23
8
23
,. : 8
248
32
257
0
0
-8
0
0
'
,tiu.
` U-G
4A5Zorn '-
_ - 0.770
sw
27.53
..
0
,
0
¢
- 0
20'
. _ .0
.., 8
0
,0
- 32
. 0
.20
, .:q)
WI--G
ocs 13A4
0.143
nw
4.OD
2.55
0
0
0
0
0
0
0
0
1Aclom
1.270
rw
35.56
45.24
0
0
0
0
0
0
0
0
�-G.
4A5-2omd
0.770
my
21.66
36.90
0
0
0
0
0
0
0
0
P .=i';12COswr
-.
-0091'.
"2.55
`:1t28.
-�88
88.
''224:
.'113
-104
r. 104'.
265
-'-133
C
i6A-30md
-.
0032
0.90
Z32
92
92
82
213
169
169
151
392
F '
M3 tpl -
0.989
- -
27.69
: 0.00
-: .. 92
- 9
249
-
• ' 0
- 169
` 14
% '388
?. : ' 0
,-52
6
c)AED excursion
25.
Envelops IossWn
1002
684
1
1768
1456
12
a) InfiRretion
162
46
252
71
b) Roomventlation
0
0
'0
0
13
Internal gains: Occupants @ 23D
0
0
0
0
Appliances/other
0
0
Subtotal Aires 6 to 13)
1163
730
2020
1527
Less e)dwW load
D
0
0
0
Lass transfer
0
0
0
0
Redistribution
0
0
0
0
14
Subtotal
1163
730
2020
1527
15
Dud loads
34%
53%
390
386
34%
53%
677
808
Total ream load
Air required(cfm)
1553
1116
1
1
2697
2335
73
48
127
100
Calculations approved byACCA to meet all requirements of Manual J 8th Ed
.eek � wrighLsOfC RlghtSuReO Universal 201717.0.14 RSU08101 2017-Apr-1017:1g:28
...k CaloslDacumentslWlTAIE-THE WINDSOR-REVISED.mp Colo =MJB Front Door faces: N
Page 6
�- wrightsoft Duct System Summary Job
Entire House By:
QUICK CALCS, INC.
317 ST. LUCIE LN., FT. PIERCE, FL 34946 Phone: 77246"799 Fax 772466-6796 Email: QUICKCALCS@10LCOM
eroject Intormation
For. WYNNE DEVELOPMENT
THE WINDSOR, FT. PIERCE, FL
EXtemal static pressure
Pressure losses
Available static pressure
Supply /. return available pressure
Lowest friction rate
Actual airflow
Total effective length. (fEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.273
in/100ft
1160
cfm
Cooling
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.273
in/100ft
1160
cfm
183 ft
Name
Design
(Btuh)
Htg
(cfm)
Clg
(cfm)
Design
FR
Diam
(In)
H x W
(In)
Duct
Mail
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
BATH
IT 586
28
16
0.372
4.0
OxO
VIFx
19.5
115.0
st1
BEDROOM
C 2730
101
117
0.384
7.0
OxO
VIFx
15.0
115.0
st1
BEDROOM
IT 2697
127
100
0.353
6.0
0x0
VIFx
26.8
115.0
st1
DININGIGREAT ROOM
c 3411
129
147
0.292
7.0
OxO
VIFx
36.5
135.0
st2
DINING/GREAT ROOM-8
C 3411
129
147
0.371
7.0
OxO
VIFx
19.9
115.0
st1
DINING/GREATROOM-C
c 3411
129
147
0.278
7.0
OxO
VIFx
44.9
135.0
st2
FOYER
h 1553
73
48
0.490
4.0
OxO
VIFx
7.0
-95.0
KITCHEN
c 2875
88
124
0.366
6.0
Ox0
VIFx
21.8
115.0
st1
LAUDRY
C 145
2
6
0.371
4.0
OxO
VIFx
19.9
115.0
st1
M. BATH
IT 1091
51
50
0.282
6.0
OxO
VIFx
42.3
135.0
st2
MASTER BEOROOM
h 3190
150
124
0.273
6.0
OxO
VIFx
48.4
135.0
st2
MASTER BEDROOM -A
h 3190
150
124
0.284
6.0
OxO
VIFx
40.9
135.0
st2
WIG
C 216
4
9
0.292 1
4.0
Ox0
VIFX
36.0
135.0
st2
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(cfm)
(Cfm)
FIR
(fpm)
(In)
(In)
Material
Trunk
st2
Peak AVF
612
602
0.273
780
12.0
0 x 0
VinlFlx
st1
st1
Peak AVF
1087
1112
0.273
796
16.0
0 x 0
VinlFlx
C + wrightsoft` S2017-Apr.1017:19:29
�� Rightuite® Universe1201717.0.14 RSU08701 ... k CaicslDocumentslWYNNE-TFE WINDSOR-REVISED.mp Calc = MJB Front Door faces: N page 1
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(cfm)
clg
(cfmp
TEL
(ft)
Design
FR
Veloc
(fpm)
Diam
(in)
I H x W
(n)
I Stud/Joist
Opening (in)
Duct
Mat[
Trunk
rb1
Ox0
1 1160
1160
0
1 0
0
0
Ox 0
VIFx
^t wri 9 htsoft' 2017-Apr-1017.19:29
RightSuiteO Universal 2017 17.0.14 RSU08101 Page 2
�� ...k CalcslDocuments\WYNNE-THE WINDSORAWSED.mp Calc =MA Front Door faces: N