Loading...
HomeMy WebLinkAboutPLANSe Residence - SAS kW Solar Photovoltaic 4stem APR 0 8 2019 IST..Luci ounty, Permitting+ a, 3 ST BLDG ' DATE: I: ELE i -„ DATE:�=t� - PLUMB:.-;`.t.y_ n .._ _..... DATE: _ 1 -MECH• c J. 4 F r DATE: 4 @� mr l4 4 r, JFST��� I =+ti' 77J7 y L t T $1 r r., j.- 'i�OI 1'i bl +aim .SICBrr i , SIUar t. r h jj Location Map r SYSTEM SUMMARY 18 HANWHA Q.PEAK DUO-G5 320/325 MODULES 1 SOLAR EDGE 6000H-US-INVERTER - SNAPnRACK RAIL SYSTEM SHEET INDEX SP SITE MAP AND PV PLAN STRUCTURAL S1 MOUNTING & ATTACHMENT PLAN S2-1 ATTACHMENT DETAILS S2-2 ATTACHMENT DETAILS ELECTRICAL E1 ELECTRICAL RISER & SCHEDULES E2 DISCONNECT & WARNING LABELS CODE TABLE APPLICABLE CODES & CERTIFICATIONS: CODES STRUCTURAL: 2015 IBC/IEBC/IRC, FBC 2017 ELECTRICAL/FIRE SAFETY: 2017 IEC, 2014 NFPA 70 & 70A, FBC 2017 '-ENERGY: SYSTEM SUMMARY 18 HANWHA Q.PEAK DUO-G5 320/325 MODULES 1 SOLAR EDGE 6000H-US-INVERTER - SNAPnRACK RAIL SYSTEM SHEET INDEX SP SITE MAP AND PV PLAN STRUCTURAL S1 MOUNTING & ATTACHMENT PLAN S2-1 ATTACHMENT DETAILS S2-2 ATTACHMENT DETAILS ELECTRICAL E1 ELECTRICAL RISER & SCHEDULES E2 DISCONNECT & WARNING LABELS CODE TABLE APPLICABLE CODES & CERTIFICATIONS: CODES STRUCTURAL: 2015 IBC/IEBC/IRC, FBC 2017 ELECTRICAL/FIRE SAFETY: 2017 IEC, 2014 NFPA 70 & 70A, FBC 2017 '-ENERGY: 2015 IECC, FBC 2017 MATERIALS CERTIFICATIONS INVERTERS: UL1741SA OPTIMIZERS: UL1703 MODULES: UL1703 RACKING: UL2703 RACK JUNCTION BOX: NEMA4X WALL JUNCTION BOX: NEMA3R CONTRACTOR .Z... CEP GOLDIN SOLAR, LLC 1309 US HIGHWAY No.1 3 * No •- -�_ VERO BEACH, FLORIDA 32960 = L/ GQ-, J MSOLAR CERTIFIED FLORIDA SOLAR CONTRACTOR c TATE' (772) 205-3244 ? '10 A, Email: permitting@goldinsolar.com ��'� • Z 0 R Web: www.GoldinSolar.com "1,111���nftNA pnurn 1717 Primrose Court, Port St. Lucie, FL 34952 SCANNED 1 St. Luce Cous4%-Y 0 A1 � N E DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER GS NO. 1902047 YCI�UO:i 3!:'.U1T8 �� In a. .a �i F r Ir k.' . —z t e .r GENERAL NOTES: 1. THE PROJECT IS DESIGNED IN GENERAL ACCORDANCE WITH THE FLORIDA BLDG CODE 2017 AND ADDITIONAL CODES AS ADDITIONALLY REFERENCED. 2. ABBREVIATIONS OTHER THAN AS PROVIDED IN TABLES/LEGENDS ARE INDUSTRY STANDARD. 3. CONDITION AND CONSTRUCTION OF ROOF FRAMING.AND ROOF COVER LAYERS SHALL BE VERIFIED BY PHYSICAL INSPECTION AND ACCEPTED BY GOLDIN SOLAR AND ANY OTHER RESPECTIVE CONTRACTOR FOR WORK -PRIOR TO PERMITTING ACTIVITIES. - 4. ALL CONTRACTORS/SUB-CONTRACTORS SHALL BE LICENSED BY THE STATE OF FLORIDA AND AS REQUIRED BY PERMITTING AGENCY. 5. NO UNLICENSED CONSTRUCTION OR TRADE WORKERS SHALL BE ALLOWED ON JOBSITE. 6. ALL GENERAL CONTRACTORS AND SUB -CONTRACTORS SHALL INSPECT THE SITE AND ANY RESPECTIVE EXISTING BUILDING IMMEDIATLEY BEFORE PREPARING ANY BID AND BEFORE ORDERING ANY MATERIALS AND SHALL PROVIDE GOLDIN SOLAR WRITTEN NOTICE OF ANY DISCREPANCY BETWEEN FIELD CONDITIONS AND THE PLANS. AFTER VERIFYING THE WRITTEN NOTICE, GOLDIN SOLAR SHALL PREPARE ANY NECESSARY PLAN REVISION, GENERALLY WITHIN 72 HOURS OF SUCH NOTICE. 7. ANY PLAN DIMENSION NEEDED BUT NOT PROVIDED SHALL BE CONFIRMED WITH THE ENGINEER OF RECORD (EOR). 8. ALTERATION OF ANY UNPLANNED, STRUCTURAL ROOF OR WALL FRAMING SHALL BE APPROVED IN ADVANCE IN WRITING BY THE FOR AND OWNER AND PLANS SHALL BE SO REVISED. 9. FIRE PROTECTION PROCEDURES SHALL BE FOLLOWED IN ACCORDANCE WITH NEC 2014, Art. 690. SEE: SHEET E3 10. ALL WORK MUST BE INSPECTED BY FOR AND BUILDING INSPECTOR PRIOR TO COVER WHICH WOULD AFFECT EASE/DURATION OF INSPECTION. 11. BEST MANAGEMENT PRACTICES SHALL BE EXERCISED AT ALL TIMES TO MAINTAIN A SAFE AND CLEAN JOBSITE IN COORDINATION WITH THE PROPERTY OWNER; THIS APPLIES TO PARKING, TRASH REMOVAL, STORAGE, SOUND, UTILITIES AND TIMES OF WORK. 12. ' NO WORK SHALL BE PERFORMED IN RIGHT-OF-WAY WITHOUT WRITTEN PERMISSION FROM THE APPROPRIATE PERMITTING AGENCY. 13. ANY DAMAGE TO PROPERTY OR BUILDING NOT UNDER THE CONTROL OF GOLDIN SOLAR SHALL BE REMEDIED BY THE OWNER. 14. ALL NEW MATERIALS SHALL MATCH EXISTING MATERIALS WHERE VISIBLE AND SHALL BE APPROVED IN WRITING BYTHE OWNER. 15. ALL MATERIALS NOT LISTED OR SPECIFIED HEREIN SHALL BE OBTAINED THROUGH CONTRACTOR -APPROVED VENDORS, GENERALLY NECESSARY TO COMPLETE TYPICAL SIMILAR CONSTRUCTION AND SHALL CONFORM TO CODE TABLE, INDUSTRY STANDARDS AND POLICIES OF THE PERMITTING AGENCY. 16. ALL DETAILS OR SPECIFICATIONS SHALL BE MATCHED TO LOCATION OR BY ARRAY. 17. IN THE EVENT OF WEATHER OR OTHER CIRCUMSTANCES THAT MATERIALLY AFFECT OR COULD HAVE AFFECTED EXISTING BUILDING CONDITIONS AFTER INSPECTION OR DURING CONSTRUCTION, GOLDIN SOLAR SHALL REINSPECT THE BUILDING ALONG WITH ANY OTHER NECESSARY CONTRACTOR AND ADJUST THE PROJECT SCHEDULE AND MAKE ANY NECESSARY PLAN REVISIONS. LEGAL DESCRIPTION: LAKE LUCIE ESTATES PLAT NO. ONE LOT 136 (OR 938-794) SITE DETAILS: PARCEL NO: 342670301500001 USE TYPE: 0100 ZONING: PUD PARCEL AREA: 10,454 SQ FT ELECTRICA MOUNT. I PRIMOSE CT \t181' ±120' ., E a to E Z N `m a m N 3�a �xMm SCALE: 1" = 20'-0" MU T 7m N'z LEGEND p N E (E) EXISTING O: n `m UJI (N) -NEW (N-I)NEW INTERIOR a, (1) INTERIOR M METER VERTEI INVERTER�` D DISCONNECT ,\\N Z�(j��,j L�p O O r� LLJ z�L a rn � uJ in.NLL a (� Lu O` u E :3 LLI a` _ d 0 a U^CL ul) 0 \ CL al� W 1••1 ul DOCUMENTS PLAN SET •CALCULATIONS ITIII IIIII(T HOp'''%,, •SPECIFICATIONS :BERnALIA TIONSMANUALS - ��``�O�•''\y ENS'/.�`F.fJ''/� UILDING PERMIT (MNTAIN COPY ON JO n ENGINEER• HW 3 Al DESIGNER: J 3(1MI DRAFTER. ARM 3WII DATE REVISION OF .p :• STATE ��'•�0, •; C O R 10 P •G�� � SHEET: 2 OF 10 SS�OINA� lx`�`�� SP DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER WIND ZONES SCALE: 1" = 10'-0" EXISTING ROOF CONSTRUCTION TYPE: GABLE DECK TYPE: PLYWOOD/OSB MATERIAL: SHINGLE SLOPE = 6:12 SUPPORT TYPE: TRUSS/RAFTER ROOF MEAN HEIGHT: 114' MOUNT HEIGHT: f6 FASTENERS/MOUNT:2 MODULE WEIGHT: 41.2 lbs. TOTAL ARRAY WEIGHT: f742 lbs. ROOF ASSEMBLY FIRE RATING (UL 790/ASTM E 108). : CLASS A EXISTING ROOF FRAMING NOTES: 1. PROPERTY APPARAISER ROOF DIMENSIONS FIELD -VERIFIED WITH DRONE & SATELLITE IMAGERY. 2. ROOF FRAMING / SPACING: 2X4 WOOD TRUSS 24" O.C. 3. WORK SHALL BE PERFORMED IN ACCORDANCE WITH EXISTING ROOF FIRE SAFETY RATING EXPOSURE NOTES: BLDG DEPT DESIGN REQUIREMENT: 160 MPH EXPOSURE CATEGORY:C STRUCTURE CATEGORY: TYPE II/ENCLOSED E Zat e 4 25'-7" 14'-6" > INn o I IG E MOUNCAL I z 0IIM) co L_Y WO5 I , �mevz o € N END ATTIC .Oy W n y RUN - GARAGE -_7— _ % ❑o �y o Z G o o� BEGIN ATTIC ° RUN Z I I I I I I I I -I I I I I I I I I I I I I I III �liil Illfll IIIIII I CL W ~ W Wif In u M U 1 U) y LL I l l i l l l l l l l l l l i W o v F i l l l l l I_I_I_I_I l i cl� E u �.. W a` Q ROOF Q r, _y ACCESS SYSTEM LEGEND U ^ V W POINT W O m 39 In. 18.25 SF MODULE a Z ;.� 661n. — — — TRUSS .L — "- - RAIL W/ ATTACHMENT .�-16'-5-16'-5°— 0 \��auuNNnn� ATTACHMENT PLAN �,\\`\\ICE HODL''�,, SCALE: 1" = 10•-0'- �•� �O• .: E NSF • F,P''. J eggs CONSTRUCTION ROOF ACCESS POINT (FIRE SAFETY). ` Tt r iJO. /f� DOCUMENTS PUN SEr ROOF ACCESS POINTS ARE LOCATED FOR FIRE DEPi.LADDER(S) CLEAR OF 7 (,�•F" ` • CALCULATIONSMO5 OPENINGS AND OBSTRUCTIONS IN ACCORDANCE WITH NFPA 11.12.2.2.1.3 - .SPECIFICATIONS .O : STA E OF NSTA AT ON MANUALS ••• •CERTIFICATIONS CONNECTOR ATTACHMENT NOTE: 10. o p; 64� BUILDING PERMIT THE .�LL..' ..O R I -_-"` c POINT. SEE:ING DETAIISAC52-1 52-2HMENT 5)TEM SHALL BE USED AT EACH ATTACHMENT /,''i''/S`S��1NAL�;\G�``�� DEER, HUU4 JW v 9 ECOFASTENER: AT EACH ATTACHMENT POINT, TWO (2) 5/16" DIAMETER STAINLESS STEEL LAG DATE PZdn OR SCREWS SHALL BE DRILLED THROUGH THE ROOF MATERIAL INTO THE TRUSS ACCORDING TO RESPECTIVE DETAIL. SHIMr 3 OF 10 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER S1 s.A� .,. .- �♦.. ..:. �, a.. .. -.. n. - .v�av ....... __ a.Y _._" s, ...�su.: Pu. ,+_ _ - ,.. q _ _15r. r.rt _. r -. Ta r. .._ .. -e•.. ._ _ t.c .a.a ......_ m. .vs ... a.. _ ...a.m.i. .-.. :.-. .� t._. _. - a. ..s .- i •bt f:I r IY 1 _. - � 1. � ... i• n. y YI $11 ...�a ��. 1♦u. � .. ♦ .j aJ�r y.3 �. .n ram, it is •� 4.+ i.; i 'at 51 b _ '.1 �I n 1 4 a. -a'ro •c... __ -- :a:S � `rla �. a � :'v'. ^ a o- ✓FVS _ .. A a O J.� n . a -.. . ROOF RAFTERS OR STRUCTURAL MEMBERS ATTACHMENT POINT SPAN BETWEEN SNAPNRACK MODULE MID CLAMPS MODULE OVERHANG ATTACHMENT: 2- 4" x 5/16" 0 SS LAG SCREWS • TORQUE 7-9 FT-LBS • RAIL CAN MOUNT TO EITHER SIDE OF POST (UP-/DOWNSLOPE) / • TWO LEVELING SPACERS PER L FOOT OR STANDOFF MAY BE USED OVERHANG: 34% OF SPAN (MAX.) • INSTALLATION MANUAL DIRECTIONS SHALL BE FOLLOWED IN ORDER �rAe a MAINSTAE4M ENERGY CORP. DESIGNER GMUFt. en ) IUD\VII h- PHONE (80515MT05 • FAx(Bp5)5 M?M DRAFTER; D Ryan SCALE DNS I PART NUMBER I S100 D05 IIRs &ja2mw - APPROVED AY' DATE 120113 STRUCTURAL SCHEDULE ITEM MANUFACTURER QUANTITY 6005 ALLOY 162" CLEARIBLACK SNAPNRACK 0 SNAPNRACK, 6005 ALLOY 122" CLEAR/BLACK SNAPNRACK 12 SNAPNRACK, STANDARD RAIL SPLICE ASSEMBLY, CLEAR SNAPNRACK 8 SNAPNRACK, BONDING MID CLAMP, 1.31 - 1.77IN, BLACK SNAPNRACK 32 SNAPNRACK GROUNDING LUG SNAPNRACK 2 SNAPBACK BONDING UNN END CLAMP ASSMBLY SNAPNRACK 8 SNAPNRACK, STANDARD RAIL END CAP SNAPNRACK 8 SNAPNRACK, WIRE RETENTION CLIP, COMPOSITE, BLACK SNAPNRACK 40 SOLAREDGE & MLPE RAIL ATTACHMENT KITS SNAPNRACK 18 FLASHING BLACK, QUICKFOOT FLASHING BLACK ECOFASTEN 36 L FOOT COMPRESSION BRACKET, QUICKFOOT MILL FINISH ECOFASTEN 36 BASE PLATE - QF-BASE 2Hole ECOFASTEN 36 31C100HCSS - 5/16-18 X 1" HEX CAP SCREW S/S ECOFASTEN 36 5/16 USS FLAT WASHER S/S ECOFASTEN 36 Bonding Channel Nut ECOFASTEN 36 NEOPRENE FLASHING CEMENT ROOF SULANT (10 OZ) GARDNER 1-12 MODULE OVERHANG (NOT EXCEED OR MANUFACTURER'S RECOMMENDATIONS) Materials Included SERIES 100 TYPICAL LAYOUT ATTACHMENT SPACING PARALLEL TO TRUSS (TYP.) 39.3" © (1) SnapNrack Junction Box Body 0 (1) SnapNrack Junction Box Lid w/Gasket ® (1) 5/16"-18 X 1-1/4' SS HCS Bolt 0 (1) SnapNrack Channel Nut © (1) 5/16"-18 X V SS HCS Bolt © (1) 5/16' 18 Self -Retaining Washer Interval Dmensions S.S-x4.5-x 3Z Iime boxarea) Material Box Palymrbonete Gasket: Rubber UL EmimnmenWl Retina Type 4X(NEMA 4X) C&rtfimtlons uL Temw.W.Rarge - 'F-185T(4VC-84C) CompbNrity Box Mount Ultra R&J, SIM SWnd=IRaY, S2MGmund Rail Intemal Mount rypeO DIN Rail Junction Box R for Rail Installation Manual Part No. 242-01104 G PERPENDICULAR TO TRUSS (TYP.) NOTES: 1. MAINTAIN ROOF EDGE TO MODULE EDGE DISTANCE: CLAY OR CONCRETE BARREL TILE: 12" CLAY OR CONCRETE FLAT TILE: 12" COMPOSITE SHINGLE: 6" METAL (5V OR STANDING SEAM): 6" 8" 52 8" 24" A D 8. _TRUSS _ MEMBER 2. ATTACHMENT POINT DIMENSIONS ARE FOR 24"O.C. TRUSSES (TYP.) 3. MAX. EDGE DISTANCE TO ATTACHMENT IS 30% OF CHORD LENGTH. 4. SPACING FIELD TOLERANCE 2"+/-, OTHERWISE FOR APPROVAL REQUIRED. O CE IH( ENS * MSTATE i �`` .5�ZOR%D L III//lllllllll\ O e 0 Z 0] Z C4 m aM H = 4 C4 9 U• = N o M SR0YI m H W O C 7 m N z 0 C-4 •0 p LU Z t In Ui M CT Q 0 M t-1 J U) 0) LL (t LLB O` N E 7 W d J O^� Urn U) 0 • PLAN SET •CALCULATIONS -SPECIFICATIONS -INSTALLATION MANUALS •CERTIFICATIONS • BUILDING PERMIT 4 OF 10 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER S2-1 QI R.38in 9.53mm ] .032in O [0.81mm ] 2X 0.331n Z 8.38mm ] 7 O 0 c c E � Nm ry E og 12.00in ISOM rl [304.BOmm[38.10mm OF-M: 1.5" C� 1.75' 877-859-3947 EcoFasten Solar® All content protected under copyright. All rights reserved. 1G/09114 QF-AL-Base GARDNER NEOPRENE FLASHING CEMENT ROOF SEALANT 100% LIQUID RUBBER MATERIAL (ASPHALT FREE); BLACK COLOR APPLICATION; NEW CONSTRUCTION AROUND VENT STACKS, SKYLIGHTS, FLASHINGS, ETC. TO SEAL LEAKS, CRACKS, HOLES AND TEARS ON EXISTING ROOFS WET OR DRY CONDITIONS MODIFIED BITUMEN SINGLE PLY'S SEALING LAPS IN SHEET METAL ROOFS PATCH AND REPAIR EPDM (COVERS APPROX 30 LIN. FT. PER TUBE) Flashing Cement Roof Sealant 3.00in [76.20mm ] .501n 8.00in [12.70mm ] [203.20mm ] EcoFasten QFL-812 Flashing MATERIALS FOR ASSEMBLY TAG NO. DESCRIPTION OF MATERIAL/PART 1 QUICKFOOT BASE PLATE 2 FASTENER (4" x 5/16" P SS LAG SCREW) 3 QUICKFOOT FLASHING 4 EPDM WASHER 5 L-102-3" BRACKET * (OTHER OPTIONS AVAILABLE) 6 5/16" EPDM BONDED 18.8 SS WASHER 7 3/8" STAINLESS STEEL HEX NUT 1. LOCATE TOP CHORD OF TRUSS AND SNAP HORIZONTAL AND VERTICAL LINES TO MARK QUIKFOOT INSTALLATION POSITIONS. 2. INSERT FLASHING WITH TOP BELOW NEXT ROW OF SHINGLES PUSHED UP TO WHERE NAILERS STOP IT. 3. CUT V-NOTCHES AT NAILER POINTS AND REINSERT UP TO STOP, PUSHED FAR ENOUGH UP SLOPE TO PREVENT WATER INFILTRATION THROUGH VERTICAL JOINT IN SHINGLES. INSTALL BARE EPDM WASHER ON STUD, PUSHING IT DOWN UNTIL IT IS FLUSH WITH THE TOP OF THE FLASHING APPLY COMPRESSION BRACKET TO STUD. INSTALL BONDED WASHER WITH RUBBER SIDE DOWN, AND TIGHTEN STAINLESS NUT TO 50 INCH -POUNDS. Flashing Installation Instructions 1 EcoFasten L-102-3 .405int.010 [10.29mmtO.25 ] F E c a� 1.88in § [47.63mm] O 75in E [19.OSmm] c E 9 o mm N 41 _u �� CE HOp OF -,. 0 R10�G��` NALE0o\``�• ST 0 E 00 0 Z In 7 N m Q M H = LL v 9 O = N o0 M SQmE tAWOc �D] NZ 0 � 4 E `W n n !t / \/ /6. S , 00 �! a W U Z�In II� U M V/ N LL o C ' E0 W 0��; U ,. t! U7 r 0 � a DOCUMENTS rJ IH H W Z W U a F- a .INSTALLATION MANUALS • CERTIFICATIONS • BUILDING PERMIT 5 OF 10 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER S2-2 PV ARRAYS (N) TOTAL OUTPUT: S,SSOW I O-String of 18 Modules JUNCTION BOX (N) - 3Q INVERTER WITH INTEGRATED ROOF DISCONNECT(N) O-STRING DETAIL ENTER SOFFIT (BEGIN optimizer 0 O ATTIC RUN) DC O O 03E AC Q-Cell D/C SWITCH INVERTER RATINGS - SEE: SPECIFICATIONS & E2 EQUIPMENT NOTES (NEC 201412017 & FBC 2017) 1. NEW EQUIPMENT SHALL COMPLY WITH NEC 110.26 CLEARANCES: 36" (FRONT), 30" (WORKARROUND), 6 FT (OH) 2. NEW EQUIPMENT AND COMPONENTS SHALL BE CERTIFIED BY A NATIONALLY RECOGNIZED LABORATORY. 3. LABEL THAT READS, "WARNING: THIS EQUIPMENT FED BY MULTIPLE SOURCES" SHALL BE PROPERLY AFFIXED. 4. LISTED OR LABELED EQUIPMENT SHALL BE INSTALLED AND USED IN ACCORDANCE WITH MANUFACTURER'S 5. INSTRUCTIONS PURSUANT TO NEC 110.3(B), AS RATED FOR OUTDOOR USE (NEMA 3-6P, NEC TABLE 110.28) ELECTRICAL SCHEDULE ITEM MODEL QUANTITY MODULE HANWHA/Q.PEAK DUO-GS 320/32S 18 OC OPTIMIZER SOLAREDGE P370 18 JUNCTION BOX SNAMRACK (NEMA 4x, ULSO) 1 INVERTER W/ INTEGRATED DISCONNECT STOREDGE 6000H-US 1 GSM Or ZIGBEE Wireless CommuNcatlon Devloe SOLAREDGE KIT OPTIONS 1 EXTERIOR BREAKER PANEL (E-I) METER F O30A ISOA SITE CONDITIONS INTERCONNECTION FREQUENCY 60 Hz VOLTAGE LINE 1/2 TO NEUTRAL 120 V VOLTAGE LINE I TO LINE 2 240V MIN/MAX ANNUAL TEMPERATURE 14'C35-C ELECTRICAL LEGEND BREAKER n FUSE M GROUND UG UNDERGROUND I I O-STRING OPTIMIZER -STRING NOTE: LOAD SIDETAP(N) NEW WITH INSTALLATION OF (NH) NEW -INTERIOR NEW 2P-30A BREAKER UG SERVICE (E) EXISTING AT OPPOSITE END OF Iph-120/240 BUSBAR (E-1) EXISTING -INTERIOR ELECTRICIAN NOTE: 1. FIELD CONFIRM FOLLOWING FEEDER & GROUND PRIOR TO WORK. 2. FEEDER(F): 344/0 THWN-2-AL, 3. GROUND: CONDUCTOR CONNECTEDTOELECTRODE EXPANSION 30INT: RUN <=75 FT, USE 4"; > 75 FT, USE 8" EXPANSION NOTES: PURSUANT TO SEC. 352.44 (NEC), EXPANSION FITTINGS SHALL BE INSTALLED BETWEEN SECURELY -MOUNTED ELBOWS AND TERMINATION POINTS (NOT INCLUDING WYES). IF JOINT IS VERTICAL, OPEN END SHALL BE SECURELY FASTENED IN DOWN POSITION WITH COUPLING INSTALLED CLOSE TO THE TOP OF RUN WITH BARREL ALSO DOWN AND LOWER END SHALL BE SECURED AT BOTTOM TO ALLOW UPWARD MOVEMENT. CONDUCTOR SCHEDULE TAG CIRCUIT CONDUCTOR SIZE DESIGN Q OCPD CONDUIT 01 PV SOURCE W WIRE-CU 2430 AWG 12.2 A N/A 3/4" EMT 0 PV OUTPUT PV WIRE.CU 2410 AWG IS A N/A 3/4" EMT 0 INVERTERINPUT THWN-2-CU 2-#10, 1-910(G)AWG 1SA N/A 3/4'EMT O INVERTERINPUT THWN-2-CU 2-#10, 1-#10 (G)AWG 15A N/A 3/4' EMT /3� '-�E Ll INVERTER OUTPUT THWN-2-CU 3-#8, 1-#8 (G)AWG 25A 30A/2PC8 I" EMT CONDUCTOR NOTE: TEMPERATURE AD3USTMENT FOR NEC 310.SS(B) #12-21A /#10-28A / #8-39A / #6-53A /#4-67A /#2-92A / #1-103A /#1/0-120A ELECTRICAL NOTES: 1. GOLDIN SOLAR SHALL FURNISH ALL LABOR, MATERIALS AND EQUIPMENT NECESSARY FOR THE INSTALLATION OF A COMPLETE ELECTRICAL SYSTEM PURSUANTTO THE PLANS IN ACCORDANCE WITH THE FBC, NEC, FHPA, OSHA AND ALL OTHER APPLICABLE CODES AND ORDINANCES. 2. ALL ELECTRICAL WORK AND RESPECTIVE PREPARATION WORK SHALL BE PERFORMED BY PROPERLY LICENSED SUBCONTRACTORS. 3. ALL MATERIALS USED SHALL BE INCLUDED IN THE PLANS AND ANY NECESSARY SUBSTITUTIONS SHALL BE APPROVED BY THE EOR. 4. ALL CONDUCTORS SHALL BE COPPER OF 98% CONDUCTIVITY. ALL CABLES SHALL BE 60OV, SINGLE -CONDUCTOR IN THERMOPLASTIC INSULATION SUITABLE FOR CONTINUOUS OPERATION AT 75 DEGREES C. CONDUCTORS AND CABLE SHALL BE NEC CLASS TYPE THW OR THWN, EXCEPT AWG SIZE #10 AND SMALLER MAY BE TW. INSULATION SHALL BE COLOR -CODED AWG #6 AND SMALLER. COLOR -CODED ELECT. TAPE SHALL BE USED ON AWG #4 AND LARGER. S. ALL CONDUCTORS SHALL BE RUN IN CONDUIT AND EXPOSED CONDUIT IS ONLY PERMITTED IN GARAGES OR OTHER AREAS ACCEPTABLE TO OWNER AND AS APPROVED BY EOR. CONDUIT SHALL BE PAINTED TO MATCH SURFACE AS REQUIRED. 6. FLEXIBLE CONDUIT SHALL BE USED FOR VIBRATING EQUIPMENT INCLUDING MOTORS AND RECESSED, MOUNTED FIXTURES AND SHALL BE SEALED WITH LIQUID TIGHT IF EXPOSED TO WEATHER WIYH A GREEN BOND CONDUCTOR INSTALLED TOGETHER AT CIRCUIT CONDUCTORS. GALV. EMT WITH SET -SCREW MAY BE USED FOR INTERIOR LOCATIONS. PVC WITH GREEN BOND CONDUCTOR SIZED IN ACCORDANCE WITH NEC 250 MAY BE USED IN UG LOCATIONS. 7. PV OUTPUT CIRCUITS ENTERING BLDG PRIOR TO INVERTEER DISCONECT SHALL BE INSTALLED IN METAL RACEWAY. 8. ALL EXISTING AND CONNECTED ELECTRICAL PANELS, CIRCUIT BREAKERS AND SAFETY SWITCHED SHALL BE SQUARE D OR EQUIVALENT. LOAD SIDE SOLAR PV-SYSTEM CIRCUIT BREAKERS SHALL BE INSTALLED AT OPPOSITE END OF BUSBAR. A LINE BREAKER DIRECTORY OF SHALL BE AFFIXED TO PANEL. 9. HVAC CONDUCTORS, CIRCUIT BREAKERS AD FUSES SHALL BE REPLACED AS NECESSARY TO COMPLY WITH MANUFACTURER'S RECOMMENDED OVERCURRENT PROTEXTION AT NO UPCHARGE AND CONDUIT AND BREAKERS SHALL BE COORDIATED WITH THE EQPT. NAMEPLATE. OTHER CIRCUITS PULLING 208-240V SHALL BE INSPECTED FOR COMPLIANCE WITH CONDUCTOR AND OVERCURRENT PROTECTION REQUIREMENTS AND REPLACEMENT SHALL BE THE RESPONSIBILITY OF THE OWNER AND ANY NECESSARY REPLACEMENT PERFORMED BEFORE GOLDIN SOLAR PERFORMS INITIAL SYSTEM TESTING. PV SPECIFICATIONS MODEL No. HANWFWQ.PEAK DUO-GS 320/325 MAXIMUM SYSTEM VOLTAGE 1000 VDC TEMP. COEF. - VOLTAGE -0.28 %/K TEMP. COEF. - CURRENT +0.04 ^/o/K TEMP. COEF. - POWER -0.37 %/K SPECIFICATIONS AT STANDARD TEST CONDITIONS (STC) MPP POWER -Pmp 320/325W MPP CURRENT - Imp _ 9.66 A. MPP VOLTAGE - Vmp 33.65 V SHORT CIRCUIT CURRENT - Iw 10.14 A OPEN CIRCUIT VOLTAGE -Voc 40.40 V DC OPTIMIZER SPECS MANUFACTURER/MODEL No. SOLAR EDGE/P370 RATED INPUT DC POWER 370W MAXIMUM INPUT VOLTAGE 60 V MAXIMUM SHORT CIRCUIT CURRENT 11A MAXIMUM OLJTpIJT CURRENT 15 A INVERTER INPUT VOLTAGE AT SPECIEZED INTERCONNECTION VOLTAGE 350V MAXIMUM POWER PER STRING 5250 W MINIMUM OPTIMIZERS PER STRING 8 NOTE: SOLAREDGE POWER OPTIMIZERS SHALL BE USED ONLY WITH SOLAR EDGE INVERTER, AS SPECIFIED ON THESE DRAWINGS. STRING LIMITATIONS APPLY, BASED ON THE INVERTER SELECTED. INVERTERS SPECIFICATIONS MANUFACTURER SOLAR EDGE MODEL NUMBER 6000H-US NOMINAL POWER OUTPUT 6000W MAXIMUM AC POWER OUTPUT 6G00 W MAXIMUM CONTINUOUS OUTPUT CURRENT AT 240V 25 A MAXIMUM DC POWER 9,300 W ELECTRICAL METALLIC TUBING (EMT) NOTES: 1. EMT SHALL BE INSTALLED ACCORDING TO NEC Art. 358. 2. CONNECTORS MUST BE CORROSION RESISTANT. 3. ALL BENDS BETWEEN PULL POINTS SHALL NOT COMBINE > 360°. 4. SECURELY FASTEN EMT @ 10 FT & 3 FT TO ANY BOX, FITTING OR TERMINAL POINT. 5. WATERTIGHT GASKETS SHALL BE PROVIDED. EMT COUPLINGS AND CONNECTORS SHALL BE RAIN -TIGHT OR RAIN-TIGHT/INSULATED. 6. SIZE OUTLET BOX ACCORDING TO NEC PER RUN. o E C TD $ Z N io Q M u0i = L6 O Pl =Q Ln m V) W 0 ,5 �mNy p)ONE Ouj uj P, d i> .� 0 O UJI z t In Lu 01 0 0 M L--I J UO y LL Lu Lu o (U O L U n- o�j, V) 'H O =:) 0. LL Y/ W J 7 0 W W cd W U) M Q U W J W PLAN SET .CALCULATIONS • SPECIFICATIONS • INSTALLATION MANUALS • CERTIFICATIONS • BUILDING PERMIT MEET: 6 OF 10 E1 ,•. e, ?.. ` , •.•., �; Fw ;. �.:.xt, [ ��:'•<, .. •: T,1M '...-.r: ..':.,:.-:a ' .. - •.. ,;. rr,. .... .." .. .... <:, _ - c .. .. 5,. ,'e' .. `'r-Y»_�:'+Y.e S' �. _nw • ..e ". q..b ... - aa3^..- x uu _. ... .. --...- ..9x-. "..._.. .+_." e. - _, ay, • ,�: r- � I ter• .. • � 4 S • Y u g9r I a 1 N _ Q Combiner Box / Circuits / Conduit Combiner Box / Enclosures./ EMT Enclosures SA\WARNINGI ® ARNINT ;GI0 ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD DONOTTOUCHTERNUNALS THE Dc CONDUCTORS OF THIS TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED PHOTOVOLTAIC SYSTEM ARE UNGROUNDED IN THE OPEN POSITION ANDUAYBEENERGNED NEC 690.17(0IPan No 596D0497 NEC 69D351F) I Part No 596-00588 I�AiWARNIPIGGGGG11 -. ©Building /Structure TURN OFF PHOTOVOLTAIC CAUTION AC DISCONNECT PRIORTO ash WORKING INSIDE PANEL NEC 710.27(C)801910.1-W49) Pan ; Pzrt No. 59fi-00499 0 DC'Disconnect / Breaker / RecoinbinerBox WANA:RNINGIN • ELECTRICAL SHOCK HAZARD - • • THE DC CONDUCTORS OF THIS _.. .. .. PHOTOVOLTAIC SYSTEM ME UNGROUNDED IFC 605.11.1, NEC690.15, NEC 690.13(B) MO MAY BE ENERGUN D Part No. 596-00238 NEC 690.35(F) I Part Na 596-00598 A WARN�IN,G ELECTRICAL SHOCK HAZARD DO NOTMUCH TERMINALS TERMINALS OH BOTH LINE AND LOAD SIDES MAY BE ENERGDFD W THE OPEN POSITION DC VOLTAGE 13 ALWAYS PRESENT WHEN SOLAR NOODS ARE EMOSED TO SUNLILEGHT NEC 690.17(E) I Pan No. 596M96 Pan No 59&00240 Iermann.Tyton DC DISCONNECT OPERATING CURRENT OPERATING VOLTAGE' 0 NIAXIMUIa SYSTEPA VOLTAGE' Sam 'SHORT CIRCUITCURRENT NEC 690,531 Part No 596-00241 NEC 690.531 Pan Na 596-DO253 0 EMT / Conduit Raceways *(Reflective Material Required) L • • L • • • ■ •• NEC 69031(GX3X4)1 Pan No. 596-00206 NEC 690.31(G)(1) I Part No. 596-00257 0 Inverter 0 Production / Net Meter /ATWARNINGa ELECTRICAL SHOCK HAZARD 6A GROUND FAVLTIS MDICATED NORMALLYG0.0UNDED CONOUCMR9 MAYBEUNGROUNDEDMOENERGGED NEC 690.5(OI Pan No. 596-00498 NEC 690.31(1)1 Pan No-596 00590 NEC 690.541 Part No. 596-00239 WAMMN N G, ELECTRICAL SHOCK HAZARD IF A GROUND FAULT IS INDICATED NORMALLY GROUNDED CONDUCTORS NAY OF UNGROUNDFDMID FNEflGD'FD NEC 690.5(C) I Pan No. 596-D0498 0 Production / Net Meter (Bi-directional) CAUTION: SOLAR ELECTRIC' SYSTEM CONNEC ED NEC 690.15 & NEC 690.13(B)1 Part No. 596 W613 AWARNINGIDUALIPOWER SOURCE sECOErO soDRCE Is PxoTovaTuO srsrEll NEC 705.12(D)(3) & NEC 690.64 Part No 596-00495 0 AC Disconnect / Breaker / Points of Connection IFC 605,113, NEC690.15, NEC 690.130 Pan No 596-00237 N0',IqJA[02ERA➢NGACV0tTAGE 1110711111 804010PRATNGAC FREQUENCY 61AXIANACCURMIT 11011111111 UAY.OtlERCURRENI QfNtE RAW FORACN00J(EPROiECTR ©a .•I hI NEC 690.13(6)1 Part N. 596-DD239 0 Breaker Panel / Pull Boxes /AZWARNINO I WN1NARNIN;=M ELECTRICAL SHOCK HAZARD ELECTRICAL SHOCK HAZARD IF AGROUND FAULT 191NOICATED THEOCMUDUCTORSOFTHI9 NDRMALLYGROUNDEDCONDUCTOR9 PHOTOVOLTAIC SYSTEM ARE UNGROUNDED MAY BE UNGROUNDED AND ENER 0 RED AND MAY BE ENERGIZED NEC 690.5(C) I Part No. 596-00498 NEC 690 35(F) I Part No. 596-00588 WAAMR-NIN E Mj WARNING ELECTRICAL SHOCK HAZARD 00 NOT TOUCH TERMINALS SINGLE 120-VOLT SUPPLY TERMINALS ON BOTH LINE AND DO NOT CONNECT LOAD SIDES MAY BE ENERGIZED MULTMRRE BRANCH CIRCUITS IN THE OPEN POSITION NEC 690.17(H I Part No. SW 00497 NEC 690 HIM I Pan No. 596-00591 /ALVIIAR�NING TURN OFF PHOTOVOLTAIC NEC 69033(E)(2) I Part No. 59600244 ACALITION ' AC DISCONNECT PRIOR TO PH-MOLTAICSTSTEM mRcuRls 9ACIFED WORKING INSIDE PANEL NEC 705.120)(3-4) & NEC 690.64 NEC 110.27(C)&OSHA 1910.145(G(7) Pan No. 596-DO587 Part No. 596-00499 OWARNINGIDUALEP•OWERSOURCE • • SECONDSODRCEBPHOTOYOLTAIC SYSTEM 25A NEC 705.120)(3) & NEC 690.641 Pat No 596-00495 • r 240V NE[690.541 Part No 596-0@39 QIWARNING NV ERIER DUTPUI,CONNECTId{OO MOT OGN I OVERGLRRENT Main Service Disconnect NEC705.12(D)(2)(3b) IPan No.59600589 WMARNIN:, • , • ELECTRICAL SHOCK HAZARD DO NOT TOUCH TERMINALS ki a • TERMINALS ON BOTH LINE AND LOAD SIDES MAY BE ENERGIZED NEC 690.15 & NEC 690.13(B) I Part No. 596OD243 IN THE OPEN POSITION - NEC 690.17(E) I Part No 596-00497 CAUTION: SOLAR ELECTRIC SYSTEM CONNECTED NEC 69015 & NEC 690,13(B) I Part No 596-00613 NEC m Main Service Disconnect / Utility Meter PURSUANT TO FLORIDA STATUE 377.705 (REVISED 7/1/2017) I, HOLLYCE HOOVER, PE (FL52666), AN ENGINEER LICENSED PURSUANT TO CHAPTER 471, CERTIFY THAT THE PV ELECTRICAL SYSTEM AND COMPONENTS ARE DESIGNED AND APPROVED USING THE CODE REQUIREMENTS AND STANDARDS CONTAINED IN THE MOST RECENT VERSION OF THE FLORIDA BUILDING CODE. GOLDIN SOLAR RECOGNIZES FLORIDA SOLAR ENERGY CENTER (FSEC) AS DEVELOPING STANDARDS FOR SOLAR ENERGY SYSTEMS MANUFACTURED OR SOLD IN FLORIDA BASED ON THE BEST CURRENTLY AVAILABLE INFORMATION IN CONSULTATION WITH SCIENTISTS, ENGINEERS AND RESEARCHERS AND DEVELOPING CRITERIA FOR TESTING THE PERFORMANCE OF SOLAR ENERGY SYSTEMS. YLp)1111IIIII„ ��,,(CE HOp�%,,% �� .Z.. .... .0 E NS . F.p ; f OF `14 vice` �. 4LE�ArL`• o E 0 In Z fV `m Q Pi TON = U. 9 �• = r4 a = a In p 1A UA0 E 7mNr• mO1^E .0 n W t In LLI , O1 0 M V / LL U) LLI o v LL1 0` —j O ^ U) V) T4 O :D CL IY J LLI CID Z M Z a 1 U W Z Z O ra CONSTRUCTION DOCUMENTS • PLAN SET •CALCULATIONS • SPECIFICATIONS • INSTALLATION MANUALS .CERTIFICATIONS • BUILDING PERMIT WINTAIN COPY ON JOB M 7 OF 10 E2 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER ' r s .y,- .. � a. � I a . a .. [ s'-. .. -' � - . .., .. .. _ • ...� w:. •Zi .vim .�.F. ... - -. � .. ... rh��L � i .e.n. k � ._ �r is _ .'.. ryr i... T � w .... � �h A / J \ y • " i !ti � - � _. �3: / ' _ y+ .... _ _ .. 'a ' � i' � � '� � r . -, � �;: _ _ �. ' .. s � `, � - � i �' :a . :. r� y - .. i ` .ti is .� _ � � � � q 4 6{ y y y •.� n 'I .j ' :py .... .., T 1 b?r• 'ii . ... ' i �. ' S„ f :) Y. �i` N � � � , 4 • ��; - L The new Q.PEAK DUO-G5 solar module from Q CELLS impresses thanks to innovative Q.ANTUM DUO Technology, which enables particularly high performance on a small surface. Q.ANTUM's world -record -holding cell concept has now been combined with state-of-the-art circuitry half cells and a six-busbar design, thus achieving outstanding performance under real conditions - both with low -intensity solar radiation as well as on hot, clear summer days. Q.ANTUM TECHNOLOGY: LOW LEVELIZED COST OF ELECTRICITY Higher yield per surface area, lower BOS costs, higher power classes, and an efficiency rate of up to 19.9 INNOVATIVE ALL-WEATHER TECHNOLOGY Optimal yields, whatever the weather with excellent low -light and temperature behavior. ENDURING HIGH PERFORMANCE QGELLS 1 Long-term yield security with Anti LID and Anti PID Technology) Hot -Spot Protect and Traceable Quality Tra.QT .-Torlwtorv: �•� i alOr EXTREME WEATHER RATING High-tech aluminum alloy frame, certified for high snow (5400 Pa) and Wind loads (4000 Pa) regarding IEC. p A RELIABLE INVESTMENT ■ Inclusive 12-year product warranty and 25-year Quality Testetl as1, linear performance guaranlee2 STATE OF THE ART MODULE TECHNOLOGY ID. 004 33268 ' Q.ANTUM DUO combines culling edge cell separation and Innovative Wiring with Q.ANTUM Technology. t APT test conditions according to IECrrS 62004-1:2015, method B (-1500 V, 168 h) r See data sheet on nearfdrfvMer THE IDEAL SOLUTION FOR: infonnaadn. ®an ,eaemew bulaf,� ® vimamal OCEIIS Engineered In Germany MECHANICAL Format SPECIFICATION 66.31n x 39.41n x 1.261n (Including frame) (1665 man x 1000 ram x 32 mm) +=n� ,°-""� • Weight 41.21bs(18,7 kg) a a .. o.-..r�.e,..x.., e.. • ^e` El Front Cover 0.131n(3.2mm)thermally presVessetl glasswim enWaOerdon teNuplogy Back Cover Composllerilm Bleep slwnNum Call Call 6 x 20 monocrystalline OAMUM selarhaticegs monocr Junction box 2.763N .35In x 1.97-2.761n x 0.51-0.83 (70-85 min a 50-70 mm x 13.21 rem), decenimb ei. IP67 Lable 4mm-Solar cable; (+) a 43.3 in It100 mm),(-) a43.3 In(1100 man) �F P .em...oTflI"+n'-•` Connecter Mu10-6anted MC4, IP68 ELECTRICAL CHARACTERISTICS POWERCLASS 316 320 325 - 330 MINIMUM PERFORMANCE AT STANDARD TEST CONDITIEBB(OTOOLERANCE+6 W I -0 Mr) Power at MPP7 N 315 320 325 330 E short Circuit Currontl JAI 10.04 10.09 10.14 10.20 E Open Circuit Voltagel M 39.87 40.13 4040 40.66 g Current at MPPI [A] 9.55 9.60 9.66 9.71 Voltage at MPP M 32.98 33.32 33.65 33,96 Emclencyt n 1%) a 18.7 a 19.0 a 19,3 a 19.6 MINIMUM PERFORMANCE AT NORMAL OPERATING CONDITIONS, NMOT2 Powerd MPP IWI 235.3 239.0 242.8 246.5 Short Clrcult Current (Al 6.09 8.13 8.17 e.22 2 Open Cimult Voltage M 37.52 37.77 38.02 38.27 -f Current at MPP aa�JAI 7.52 7.56 7.60 Test Voltage at MPP M 31.30 31.62 31.04 3225 1Measurememtolemnm PNPP e 3 %; IBC; VOCxS %at STL: tOrcYa92C, AM 1.SG aaordum b IEC 609043eWWfM, NMOT, sceawn AM 1.SG %CELLS PERFORMANCE WARRANTY- RERFORMANCE AT LOW IRRADIANCE a At leastea% ofnommalpowerdurhlg ruslyear. Themederan. O.54% degraaakeperyear. Atleastomss steamiest pmveruplo toyeam. '+ 5' +sun Atleasta5% ofnombal lxrvrerup to 25 yeen. :o Alldetawibb measurement tolerances, w + FUll wemntles b acmrd.mm aM the we:rent, $ term.V0.0CELLSsalmmgenlralkenofyour I$ esceaw ounh. a w w _ Iw,'rmxae2'(imkl w • ne • yEWa Typical modulepedo:mance underlowlrtedlenceeondNonsN a•a nm�,' comparison to STC oond4lons (25'c, 100c vVrr2 TEMPERATURE COEFFICIENTS _ - _ '. Tempereture Coemdent of lsc a [%/Kl 40.04 Temperature Coefficient ofVOC p rAI KI -0.28 Temperature Coefllclent of PMPP y 1%/19 -0.37 Normal Module Operating TemperatureNMOT rF[ 109 t 5,4(43 a 3•C) PROPERTIES O. SYSTEM DESIGN Maxlmum System Voltage VSYS M IODO(IEC)/ 1000(UL) Safety Class II Maximum Sense Fuse Rating [A DC) 20 Fire Rating C (IEC) /TYPE 1 (UL) Max. Design Load, push2 pbMq 75(36DO Pa)/ 55(2667 Pa) Permitted module temperature -40'F up to.185-F on continuous duty (-0'C up to•85-C) Max. Test Load, Push I PUI12 [IbsW 113 (5400 Pa) / a4 (4000 Pa) r see Installation manual QUALIFICATIONS AND CERTIFICATES PACKAGING INFORMATION UL 1703: WE Cuouty Tested; CE complaM Number of Modules per Pallet 32 IEC 61216:2016; IEC 61730:201, epplic hon less A � Number of Pallets per 63' Trailer 30' Number of Pallets per40' High Cube Container 26 L .1 C E Oyu Pallet Dimensions(L x W• H) 69.31n x 45.3 In . 45.9N I me (1760 ram x 1150 men x 1190 man) Pallet Weight 14151bs (642 kg) NOW: installation becuctlons must be followed. See be installaton and operating manual or centadouNerAnkal seMcetleparMemfar Ndherinbmle8on on epPmved NslaneWn erquse Of pmaud. HanwM G CE Amedca Inc. 300 Spectrum Censer Dr., Suet. 1250. 1N me, CA 92618. USA I TEL*1649 Its 56 N I EMAIL Inquiry®ut.t,auh.cem I Was www.eceus.us `tt1111111111111//7yy �j Hpp`% 'STATE OF i F4OR10 G�Cv: s/OINA�%\\1\`°• Z 0 laaa Ixi LL N W CL 'ww YI W J r�1 DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLFES SIGNED AND SEALED BY ENGINEER Power Optimizer For North America - P320 J- P340-/-P370 /-P-400 PV power optimization at the module -level / Specifically designed to work with SolarEdge / Fast installation with a single bolt inverters / Next generation maintenance withmodule- / Up to 25%more energy level monitoring / Superior efficiency(99.5%) / Meets NEC requirements for arc fault / Mitigates all types of module mismatch losses, protection (AFCI) and Photovoltaic Rapid Shutdown System (PVRSS) from manufacturing tolerance to partial shading / Module -level voltage shutdown for installer / Flexible system for maximum space firefighter safety - utilizationdesign utilization I I solaredge.com solar=@@ / Power Optimizer For North America P320 / P340 / P370 / P400 / P405 / P505 RMW Input DC Pam(1) Me 3W 370 400 405 505 W Alzelute Malmum rpu v.ft4. (vonath.th'.he.W ) 40 60 00 gem oA Van MPPT0Mm1hhgRange 0-48 8-W B-BJ 125-105 125-a) Van Marlmum Shod CinudC IM41 11 10A 14 Aac Maximum DC lr,tCurteM 13.7E 1253 17.5 Ad. Malmum Eftaexy 995 % Weighted affd q "'a 9&6 % Overvce4ge chawry II (OUTPUT DURING OPERATION (POWER OPTIMIZER CONNECTED TO OPERATING SOLAREDGE INVERTER) Mayrnum Output OuneN 15 PAc Malmum ONpN Valtajle W 95 Vdc U V 1 r V I UUNINU.a 1ANUNY (F.UeytH OF I (MILER UIJUUNNEG I EU FRUM JOLAREDGE INVERTER OR SOLAREDGE INVERTER OFF) pares our W V0hze mr 1: oe vac Malmum AMa SWra VPPage 1oW vac C.M,VbWfire.m All Sol2rE90 Single Phase vN TM1ree FNa 6 m Dlmemlvu(WxLx HIWaght 128x 152a ZB/5z6.9]a1.1 128x 15L 38/ 4Bx 162z50/ SZ S.Wx1.43 5x58]v 1.86 12av 152x591 5x5.W x2ffi mmlN cables) 63011A ]50/1.] B4511.9 1004/23 grlA hn1C.lndWlip NPALRnnMa .w Ou Whe Type/C w Double I.esx:MU OU hWM.Legm 0.95/3.0 1.213.9 mIM1 Input W1re Lapth 0.1610.52 m1A Ocerasrg TemperaWre Rap 40- 551io-+105 -CIT Preec6en <taBm IP60l NEMPSP Rela,aHr1ft 1 0-100 % m�pmm{vvsmvm eio�vi a2in5mlr 11�eMrev ma ITu1'MPoM M M nvs tivn R! 1VM+PIvmvwem Sb-N9s Single phase 4 Three Phase 2084 Minimum SObp Werh P32�'P340, P3)0, HD�Wave 0 10 10 (Power OPtlmherm) P4051 P505 B a 14 Mexlmumbhing LepN 25 25 P.rL ..n me 570.911 Mazmm Powe lur PerSMry SE)600-', 0-US -6E11 5250 9000(]I 12]SgBI W US) Pamnel svmB. m D merem LerpOu Yes or OrkMeSmm obM4•IMeYgbltl/JlpevurmLL50i.VLZEa•Lw,fe}xyaMlu¢PaY50Y46[�uin.IuvyyJuympg56Fq iJmbpvle [E ROHS 0 Q V N LL N W 'raA Y/ ce W N !N L 01111111111///)// NN ,\11 J OMV /)/ IL 0,E14 :F,p STATE OF r 0%' • F4 0 R 10...`.G��v`. )„/INI nm%%P r -1 Lt DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED DY ENGINEER 7% Its W 30, "0 x. v. ty ti to so- 4 / Single Phase Inverter with HD -Wave Technology for North America SE3000H-US / SE380OH-US / SE5000H-US / SE6000H-US/ Single Phase Inverter SE760OH-US / SE10000H-US / SE1140OH-US_ HD with —Wave Technology.. Rated AC Power Dulput 3000 380011240V 3]00 dD 208V 5000 6ad011240V 5c00 gg 20BV ,6pp t000p D6000 VA for North America T Minimum AC Power Ouput 3000 3800®240V 3300®2d8V 500p 60.. G' V 5ggg®268V T600 10000 11400p VA SE3000H-US./ SE380OH-US / SE5000WUS / SE6000H-US / /T�, / — AG OumNNonage MN.-Nem.M11az. °°'-2°°-'29) AC OupN Vdppe Mln.J4om. •.�. 3 - 3 - - - Vee SE7600H=US / SE1 OOOOH-US / SE1140OH-US (211-2402R) AC FreVenry (Nomnel) ] ] 3 3 3 ) 3 Vac 59.3.60-60.5(1) Hz o. -.. .. .. ' Medwm Cmomtoun Ouput C .M208V - 16 - q Msewm Cm6nuWs Gupta Cat. 125 16 21 25 32 42 R.5 A - O W) a �®-! .' • va GMIRata GFDI TNeMdtl ud1ty Mondor6p, ISlandmg 1 A - - (O mbEUS ..JD... • i C Protace CWI CmSgurade Yee INPUT INPUT jh 0 p MaaNmm CC Power@240V 4650 59M 770 9300 118M 15500 R650 W `• r - • a illllllll1:�T / 111111111/ ,- M.mrn DCPmrer®20N - 5100 - 77W - - - Ij - (jj ' ••�••` `, - Tnmtmmer4.1. Ungrounded Yes ! i •••• -/ —� J Mmlmuminput Vothep 480 Vds • - � y--•� D • _ a .". " Nam MDCMput VaOage Medmuml1utCweM20N(2) 3W 400 Vdc 6 13.5 - - - `4 • NR7 B.5 10.5 135 16. 20 Z7 SO.s Me .. • • 4.�I ,,. Meallnput Cited tDon Revesefedpn detly Rd Ya 'v�'� - Ground-Faudbddon Detac 6001,6e M^ • •i •?^. i �• - .. Maeunum lrneNr Effidavy 89 992 % CEC Weighted! EK'ercy 99 % - NlghNme Power Consumptbn e2.6 W ADDITIONAL FEATURES " - - SI,ratl C...Itatlon lMe,fIa R6485. EMemep LgBee(op6onal). CeWler(opSenaD Optimized installation with HD -Wave technology / SpecifiEally designed to work with / Extremely small power optimizers Record -breaking efficiency If Built-in module -level monitoring Fused voltage Inverter for longer strings / Outdoor and indoor installation / Integrated arc fault protection and rapid shutdown for I Optional Revenue grade data, ANSI C1Z20 NEC 2014 and 2017, per article 690.11 and 690.12 Class 0.5 (0.5% accuracy) / UL1741 SA certified, for CPUC Rule 21 grid compliance 301]680.12 oma6a 20170•1•••••••-••`•---•-•••" ANRIM D upon AC GM Dbwnnea Cdd DOMeeIa steadanb IEEEI547. Rute 21. Rub 14 (H1) Emieaba i FCC Per 15 Cast B INSTALLATION SPECIFICATIONS ACOutput ConcLft 4e/AWG R., L4-mWmrmIIHAWG L{'mbimumllH RYLG DO Inputt,,e Sim /t ol5hba AWD Rage 3/4-nudmum/1-2 ofn,s/Wfi AWG W/ mi mum/1-3st(ugs/14d AWG DMenalona wIN SafaW Switch (lyyyap) 13.7a14.8a8.8/450a370y174 21.3XI4.5X?.31540X3T0Y165 In/ min WCIQMw1%8araty S00h 22110 25.1111.4 26.2/11S 38.8117.6 Ib/Yg Ndse i 60 d9A Coohg NaturalConvedon Neeadc.Ifian 0pera4np Tempera ara Renee -13 W 41401-25 N a6D(4) (40'F 14WC ep enXS) T/Y Notedon Rang NEMA4XQnvertewithsafely SwBch) pFpOMipbnl Yahgegrvevm! iFaluE��eewept gAN]rH mnNs'iaa mw MussLtlehrYtwwlllOmlmlryNnmearo VenY9aaNf solaredge.com solaI:iiaFaa� aaee�.d>.mmeeeafand•.a+asnw�.e+«.nw�m.�+,dr r- • e 640—aeap696 ObNHW aWrveerlavaaa9YvhY.Y/iv.mnASQYID4E q. Wh43.ag6ma�a6fSNAy.'YnavMneNprg6mNMm�IMSJRP�aIMne4yb.MY vab mnbM bnN e. vabmvb d eva mp.e�v enaa pv r}/X�iMggG 1 VY ya}a m vmq YpY naK CC ROHS O Pal N lL N .IL Www Y/ ce W ld W H DISCLAIMER: PLAN SHEET FOR REFERENCE ONLY UNLESS SIGNED AND SEALED BY ENGINEER