EVALUATION REPORT St. Lucie County
Tarco Roofing
One Information Way, Suite 225
Little Rock, AR 72202
(254)913-7750
EXTERIOR RESEARCH & DESIGN, I.I.C.
Certificate of Authorization N9503
353 Christian Street, Unit 13
Oxford, CT 06478
(203) 262-9245
Evaluation Report
Date of Issuance:
Revision 3:10/02/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION* LeakBartier0 EasyStick al Modified Bitumen Roo stems�
LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity) ERD requires a complete review of this
Evaluation. Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TRINrryIERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPEc iON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 3-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
Thefaclmil'ie seal appearing was authorized by Robert Nkminen, P.E.
on 10102/2017. This does not serve as an electronically signed
document.
CERTIFICATION OF INDEPENDENCE:
1. Exterior Research & Design, LLC. d/b/a Trinity ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in
any company manufacturing or distributing products it evaluates.
2. Exterior Research & Design, LLC. d/b/a TrinitylERD is not owned, operated or controlled by any company manufacturing or
distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, In any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
\ TRINITY ERD
ROOFING SYSTEMS EVALUATION:
1. SCOPE:
Product Category: Roofing,
Sub -Category: Modified Bitumen Roof Systems
Compliance Statement: LeakBarrier® EasyStickm Modified Bitumen Roof Systems, as produced by Tarco Roofing,
have demonstrated compliance with the following sections of the 6" Edition (2017) Florida Building Code through
testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and
Limitations / Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind
FM 4474
2011
1504.7
Impact
FM 4470
2012
1507.10.2
Physical Properties
ASTM D226
2009
1507.10.2
Physical Properties
ASTM D4601
2012
1507.11.2
Physical Properties
ASTM D6163
2008
1507.11.2
Physical Properties
ASTM D6164
2011
3. REFERENCES:
Enti
Examination
Reference
Date
PRI (TST5878)
Physical Properties
TOT-041-02-01
05/24/2006
ERD (TST6049)
Wind - FM447014474
TAR-SC7960.01.16
01/31/2016
ERD (TST6049)
Wind -. FM4470/4474
TAR-SC5670.03.16
03/21/2016
ERD (TST6049)
Wind - FM4470/4474
T6460.06.07-R2
05/26/2017
ERD (TST6049)
Physical Properties
T6470.08.07-R2
06/02/2017
UL (QUA1743)
Quality Assurance
Service Confirmation
Exp. 06/28/2020
4. PRODUCT DESCRIPTION:
This Evaluation Report covers LeakBarrier® EasyStickTM Modified Bitumen Roof Systems installed in accordance with
Tarco Roofing published installation instructions and the Limitations / Conditions of Use herein. The following
products make up the subject systems.
TABLE 1: ROLL -GOODS FOR LEAKBARRIER®.EASYSnckm MODIFIED' BITUMEN ROOF SYSTEMS , ..
Type
Product
Specification
Reference
Type
Grade
Base Sheets:
LeakBarrier® EasyLaym
ASTM D226
II
N/A
LeakBarrier® EasyNailBase'""
ASTM D4
(published)
II
N/A
Smooth Surfaced Membranes:
LeakBarrier® EasyBase'
ASTM D6163
'I
S
Granule Surfaced Membranes:
LeakBarrier® EasyStick"
ASTM D6164.
I
G
Exterior Research and Design, U.C. Evaluation Report T39820.12.11-R3
Certlflcate ofAuthcrizatlon 09503 6r"EDITION (2o17)FBC NON-HVHZ EVALUATION FL9487-RS
LeakBarrier° EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017
Page 2 of 4
-,I I KINITY ERD
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinity IERD nor Robert.Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used
for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire classification does not form part of this Evaluation Report; refer to a current Approved Roofing Materials
Directory for fire ratings of this product.
5.4 For,steel deck installations, foam plastic insulation shall be separated from the building interior in accordance
with FBC 2603.4unless the .exceptions stated in FBC 2603.4.1 and 2603.6 apply.
5.5 The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural
members shall be in accordance with FBC requirements to the satisfaction of the Authority Having
Jurisdiction. Load resistance of the roof deck shall be documented through proper codified and/or FBC
Approval documentation.
5.6 For recover installations, the existing roof shall be examined in accordance with FBC-1511.
5.7 For mechanically attached insulation or membrane or strip -bonded insulation, the maximum design pressure
for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with
FBC Chapter 16. Zones 2 and 3 shall employ an attachment density designed by a qualified design
professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS
137. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.16.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.8 For assemblies with all components fully bonded in place, the maximum design pressure for the selected
assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16. No
rational, analysis is permitted for these systems.
5.9 For mechanically attached insulation or membrane over existing roof decks, fasteners shall be tested in the
existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison
to the minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI
Fx-1 or Testing Application Standard TAS 105.
5.10 For bonded insulation or membrane over existing substrates in a re -roof (tear off) or recover installation, the
existing.deck or existing roof surface shall be examined for compatibility with the adhesive to be installed. if
anysurfaceconditions exist that bring system performance into question, field uplift testing in accordance
with ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS
124 shall be conducted on mock-ups of the proposed new roof assembly.
5.11 For bonded insulation or membrane over existing substrates in a recover installation, the existing roof
system shall be capable of resisting project design pressures on its own merit to the satisfaction of the
Authority Having Jurisdiction, as documented through fielduplift testing in accordance with ASTM E907, FM
Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
5.12 Metal edge attachment (except gutters), shall be designed and installed for wind loads in accordance with
FBC Chapter 16 and tested for resistance in accordance with AN51/SPRI ES-1 or Roofing Application Standard
RAS 111, except the basic wind speed shall be determined from FBC Figure 1609.3(1), 1609.3(2) or
1609.3(3).
5.13 All products in the roof assembly shall have quality assurance in accordance with FAC Rule 61G20-3.
Exterior Research and Design, I.I.C. Evaluation Report T39820.12.11-R3
Cerolrcate of quthodzation#9503 61X EDITION (2017) FBC NON-HVHZ EVALUATION FL9487-RS
LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02/2017
Page 3 of 4
\, TRINITY ERD
6. INSTALLATION:
6.1 EasyStickm Modified Bitumen Roof Systems shall be installed in accordance with Tarco Roofing published
installation instructions, subject to the Limitations / Conditions of Use noted herein.
6.2 System attachment requirements for wind load resistance are set forth in Appendix 1. "MDP" = Maximum
Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects
the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been
applied). Refer to FBC 1609 for determination of design wind loads.
7. BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Contact the named QA entity for manufacturing facilities covered by F.A.C._ Rule 61G20-3 QA requirements.
9. QUALITY ASSURANCE ENTITY:
Underwriters Laboratories —QUA1743; (414) 248-6409; Karen.buchmann@us.ul.com
- THE THREE (3) PAGES THAT FOLLOWS FORMS PART OF THIS EVALUATION REPORT -
Exterior Research and Design, I.I.C. Evaluation Report T39820,12.
Certificate of)lWorkation M03 6'"EDITION (2017)FBC NON-HVH2 EVALUATION ,FL94970M
LeakBarrier® EasyStick Modified Bitumen Roof Systems Revision 3: 10/02 2017
Page 4 of 4
VT-RINITYIERD
APPENDIX I: ATTACHMENT REQUIREMENTS FOR WIND UPLIFT RESISTANCE
Table
Deck
Application
Type
Description
Page
1A
Wood
New, Reroof (Tear -Off) or Recover
C
Mach. Attached Insulation, Bonded Roof Cover
2
1B
Wood
New, Reroof (Tear -Off) or Recover
D
Insulated, Mach. Attached Base Sheet, Bonded Roof Cover
2
IC-1
Wood
New or Reroof (Tear -Off)
E
Non -Insulated, Mach. Attached Base Sheet (nails), Bonded Roof Cover
2
1C-2 Wood New, Reroof (Tear -Off) or Recover E Non -Insulated, Mech. Attached Base Sheet (screws & plates), Bonded Roof Cover 3
1D Wood New or Reroof (Tear -Off) F Non -Insulated, Bonded Roof Cover 3
The following notes apply to the systems outlined herein:
1. The roof system evaluation herein pertains to above -deck roof components. Roof decks and structural members shall be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Load resistance of the roof deck shall be documented through proper codified and/or FBC Approval documentation.
2. Unless otherwise noted, fasteners and stress plates for Insulation attachment shall be as follows. Fasteners shall be of sufficient length forthe following engagements:
➢ Wood Deck: OMG 412 or k14 HD with OMG 3 In. Galvalume Steel Plate (non -ribbed) or Tru-Fast,DP or HD with Trufast 3" Metal Insulation Plates. Minimum'/. -Inch plywood penetration or minimum
1-inch wood plank embedment.
3. Unless otherwise noted, Insulation may be any one layer or combination of polyisocyanurate, polystyrene, wood fiberboard, perlite or gypsum -based roof board that meets the QA requirements of F.A.C. Rule 61G2G-
3 and is documented as meeting FBC 1505.1 and, for foam plastic, FBC Chapter 26, when installed with the roof cover.
4. For mechanically attached components or partially bonded insulation, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC
Chapter 16, and Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDI, FM Loss
Prevention Data Sheet 1-29, Roofing Application Standard RAS 117 and Roofing Application Standard RAS 137. Assemblies marked with an asterisk- carry the limitations set forth in Section 2.2.10.1 of FM Loss
Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
S. For assemblies where all components are fully adhered, the maximum design pressure for the selected assembly shall meet or exceed critical design pressure determined in accordance with FBC Chapter 16, and no
rational analysis is permitted.
6. For mechanically attached components over existing decks, fasteners shall be tested in the existing deck for withdrawal resistance. A qualified design professional shall review the data for comparison to the.
minimum requirements for the system. Testing and analysis shall be in accordance with ANSI/SPRI FX-1 or Testing Application Stanard TAS 105.
7. For existing substrates in a bonded recover or re -roof installation, the existing roof surface or existing roof deck shall be examined for compatibility and bond performance with the selected adhesive, and the existing
roof system (for recover) shall be capable of resisting project design pressures on Its own merit to the satisfaction of the Authority Having Jurisdiction, as documented through field uplift testing in accordance with
ANSI/SPRI IA-1, ASTM E907, FM Loss Prevention Data Sheet 1-52 or Testing Application Standard TAS 124.
8. "MDP" = Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, I.I.C. d/b/a Trinity(ERD Evaluation Report T39820.12.11-R3f rF 7-RS
Certificate of Authorization #9503 6'y EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3: 10/02/2017
Prepared by: Robert Nieminen, PE-59166 LeakBarrier° EasyStick- Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 1 of 3
VTRINITYIERD
TABLE 1A: WOOD DECKS-- NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE C; MECHANICALLY ATTACHED INSULATION, BONDED ROOF COVER
System
Top Insulation layer
_ Roof Cover
MDP
No.
Deck (Note 1)
Base Insulation Layer
(Psf)
Type
Fasteners
Attach
Base Ply
Ply
Cap
W-1'
Min. 15/32" plywood
(Optional) One or more layers,
Min. 3/8-Inch SECUROCK Gypsum-
Note 2
1 per 1 ft a
EasyBase
(Optional) EasyBase
EasyStick Plus
-52.5
at max. 24" spans
any combination; loose laid
Fiber Roof Board
W 2
Min. 15/32" plywood
(Optional) One or more layers,
Min. 2-inch ACFoam II, EnergyGuard
Polyiso, ENRGY 3, H-Shield, 150 95*
Note 2
1 per 1 fe
EasyBase
(Optional) EasyBase
EasyStick Plus
-82.5
at max. 2e spans
any combination, loose laid
GL or Multi -Max FA3
TABLE.IB: WOOD DECKS -NEW CONSTRUCTION, REROOF (Tear -Off) or RECOVER
SYSTEM TYPE D: INSULATED, MECHANICALLY ATTACHED BASE SHEET, BONDED ROOF COVER
System
Insulation Layer
Base Sheet
Roof Cover
MDP
No.
Deck (Nate 1)
Type
Attach
Type
Fasteners
Attach
Base Ply
Cap
(psi)
W-3.
Min. 15/32" plywood
Any type, thickness or
Loose laid
Earylay
Note 2
10-inch o.c. in the min. 4-inch lap and 10-inch o.c.
One or two plies,
EasyStick Plus
-60.0
at max. 24' spans
combination
in two (2), equally spaced, staggered center rows
EasyBase
W 4
Min. 15/32" plywood
Any type, thickness or
Loose laid
EaryLay
Note 2
B-inch o.c. in the min. 4-inch lap and B-inch o.c. in
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
combination
four (4), equally spaced, staggered center rows
EasyBase
W 5
Min. 15/32" plywood
Any type, thickness or
Loose laid
EasyNailBase
Note 2
6-Inch o.c. In the min. 4-Inch lap and 6-inch o.c. In
One or two plies,
�asy5tick Plus
-135.0
at max. 24" spans
combination
four (4), equally spaced, staggered center rows
EasyBase
TABLE IC-1: WOOD DECKS — NEW CONSTRUCTION or REROOF (Tear -Off)
SYSTEM TYPE E; NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (nails), BONDED ROOF COVER _
System
Base Sheet
Roof Cover
MDP
Deck (Note 1)
No.
Type
Fasteners
Attach
Base Ply
Cap
(Psi)
W-6'
Min. 19/32" plywood
EaryLay
12 ga. annular ring shank nails and min. 32 ga.,1-5/8"
7-inch o.c. in the 4-Inch lap and 7-inch o.c. in three
One or two plies,
EasyStick Plus
-60.0
at max. 24" spans
diameter tin -caps. (Ref: FBC 1517.5)
(3), equally spaced, staggered center rows
EasyBase
-7.
Min SI32',pfllivo3d
Easy ey:�
Sj pitti a MA)0(Cap Faste`ne`f,''.tL�
B Intp-o:rlrLahe nrht i c lap and 8;incho.c r
Oneurt mptl s,
EasyBase
Eas SYtc lus
-82:
at .spa
�->y-�-_ p --
our ;gq_ally5paceastagg Brent@rr-, ow; .x
W-8.
Min. 15/32" plywood
EaryLay
12 ga. annular ring shank nails and min. 32 ga.,1-5/8'
4-Inch o.c. in the 4-inch lap and 4-inch o.c. in four
One or two plies,
EasyStick Plus
-120.0
at max. 24"spans
diameter tin -caps. (Ref: FBC 1517.5)
(4), equally spaced, staggered center rows
EasyBase
W-9'
Min.
Min. 15/32" plywood
EaryNailBase
12 ga. annular ring shank nails and min. 32 ga., 1-5/8"
4-inch o.c. in the 4-inch lap and 4-inch o.c. in five
One octavo plies,
EasyStick Plus
-120.0
24" spans
diameter tin -caps. (Ref: FBC 1517.5)
(5), equally spaced, staggered center rows
EasyBase
Exterior Research and Design, U.C. d/b/a Trinity ERD Evaluation Report T39820.12.11-R3f rFL9487-RS
Certificate of Authorization #9503 6'" EDITION (2017) FBC NON-HVHZ EVALUATION Revision 3:10 02/20I
IIIIf
Prepared by: Robert Nieminen, PE-59166 LeakBarrier° EasyStick- Modified Bitumen Roof Systems; (254) 913.7750 Appendix 1, Page 2 of 3
�! TRINITY ERD
TABLE SC-2: WOOD DECKS— NEW CONSTRUCTION, REROOF,(Tear-Off) or RECOVER
'SYSTEM TYPE E: NON -INSULATED, MECHANICALLY ATTACHED BASE SHEET (screws.& plates), BONDED ROOF COVER -
System
Base Sheet
Roof Cover
MDP
Deck (Note 1)
No.
Type
Fasteners
Attach
Base Ply
Cap
(PsQ
W-10.
Min. 15/32" plywood
EaryLay
Note 2
10-inch o.c, in the min. 4-inch lap and 10-inch o.c. in two (2), equally spaced,
One or two plies,
EasyStick Plus
-60.0
at max. 24" spans
staggered center rows
EasyBase
W-IS.
Min. 15/32" plywood
EasyLay
Note 2
8-Inch o.c. In the min. 4-inch lap and 8-inch o.c. in four (4), equally spaced,
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
staggered center rows
EasyBase
W 12
Min. 15/32" plywood
EasyNallBase
Note 2
6-inch o.c. in the min. 4-inch lap and 6-inch o.c. in four (4), equally spaced,
One or two plies,
EasyStick Plus
-135.0
at max. 24" spans
staggered center rows
EasyBase
' TABLE ID:WOODDECKS—,NEWCONSTRUCTION or REROOF(Tear-Off)
SYSTEM TYPE F:.. BONDED ROOF COVER
System
Deck (Note 1)
Roof Cover
MDP
No.
Type
Joint Treatment
Base Ply
Ply
Cap
(Psf)
W-13.
plywood
at max.x. 2424" spans
at m"
None
(Optional) EasyBase
(Optional) EasyBase
EasyStick Plus
-75.0
W-14.
Min. 15/32"plywood
Plywood joints are covered with 4-Inch wide strips of EasyBase, rolled Into
(Optional) EasyBase
(Optional) EasyBase
EasyStick Plus
-120.0
at max. 24" spans
place to create continuous bond.
Exterior Research and Design, I.I.C. d/b/aTrinity I ERD Evaluation Report T39820.12.11-R3 f FL94B7-RS
Certificate o)Authorkation #9503 6ry EORION (2017) FBC NON-HVH2 EVALUATION Revision 3: 10/02 2 f
Prepared by: Robert Nieminen, PE-59166 LeakBarrier® EasyStick^' Modified Bitumen Roof Systems; (254) 913-7750 Appendix 1, Page 3 of 3
CREEK
TECHNICAL SERVICES, LLC
EVALUATION REPORT
Manufacturer:
Manufacturing:
Quality Assurance:
SCOPE
Certificate of Authorization No. 29824
17520 Edinburgh Dr
Tampa, FL 33647
(813)480-3421
FLORIDA BUILDING CODE, C EDITION (2017)
SCANNED Issued October9, 2018
BY
iCounty
www.drexmet.com St. Luce
RECEIVED
Drexel Metals Association of Regional Manufacturers (DM -ARM)
APR 88 7019
Architectural Testing, Inc. (QUA1844)
ST. Lucie County, Permitting
DREXEL METALS, INC.
1234 Gardiner Lane
Louisville, KY 40213
(502) 716-7143
Category: .Roofing
Subcategory: Metal Roofin .
Code Sections: 1504.3
Properties: Wind Resistance
REFERENCES
Entitv
Report No.
Standard
Year
Architectural Testing (TST1558)
56840.02-122-18
TAS 100
1995
Architectural Testing (TST1558)
58389.01-122-44
UL 580
2006
Architectural Testing (TST1558)
58459.01-122-44
UL 580
2006
Architectural Testing (TST1558)
58461.01-122-44
TAS 125
2003
Architectural Testing (TST1558)
82776.01-109-44
UL 580
2006
UL1897
2012
AmhBectural Testing (TST1558)
82784.01-109-44
UL 680
2006
UL1897
2012
Architectural Testing (TST1558)
83296.01-109-44
UL 580
2006
UL1897
2012
Architectural Testing, Inc (an Intertek Company) (TST1527)
H3245.01-450-18
TAS 125
2003
Architectural Testing, Inc (an Intertek Company) (TST1527)
H9058.02-050-18
TAS 125
2003
Architectural Testing, Inc (an Intertek Company) (TST1527)
H9058.01-450-18
TAS 125
2003
Architectural Testing, Inc (an Intertek Company) (TST1527)
13391.01-450-44
UL 580
2006
Force Engineering & Testing (TST5328)
178-0054T-12
UL 580
2006
UL1897
2012
Force Engineering & Testing-(TST5328)
178-0055T-12
UL 580
2006
UL 1897
2012
Hurricane Test Laboratory (TST1527)
0287-0209-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0308-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0311-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0313-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0512-07
TAS 125
2003
Hurricane Test Laboratory (TST1527)
0287-0706-07
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
VLS-005-02-01
ASTM B 117
2016
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
VLS-004-02-01
ASTM G 155
2005a
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
DMC-004-02-01
TAS 125
2003
PRI Construction Materials Technologies (TS75878)
DMC-005-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-006-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-007-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-008-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-009-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-014-02-01
TAS 125
2003
PRI Construction Materials Technologies (TST5878)
DMC-016-02-01
TAS 100
1995
PRI Construction Materials Technologies (TST5878)
DMC-017-02-01 Rev 1
UL 580
2006
UL 1897
2012
DRX15001.6 F.
S:R6
Page 1 of 5
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed heroin.
®CREEK
TECHNICAL SERVICES, LLC
Enti
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRI Construction Materials Technologies (TST5878)
PRODUCT DESCRIPTION
DREXEL METALS, INC.
Metal Roofing
Report No.
Standard
Year
DMC-018-02-01
UL 580
2006
UL 1897
2012
DMC-024-02-01
UL 580
2006
UL 1897
2012
DMC-033-02-01.1
UL 580
2006
UL 1897
2012
DMC-037-02-01
UL 580
2006
UL 1897
2012
DMC-037-02-02
UL 580
2006
UL 1897
2012
DMC-038-02-01
UL 580
2006
UL 1897
2012
I) _ C;OUNS
Profile:
1 in. snap lock seam; Max.16 in. coverage
Description:
_
Non-structural, snap lock standing seam roof panel with integral perorated nail
strip
Material:
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fr, = min. 50 ksi; Shall conform with FBC Section 1507.4.3
16
r
DMC 150SL
Profile:
1.5 in. snap lock seam; Max. 16 in. coverage
Description:
Non-structural, snap lock standing seam roof panel
Material:
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fermin. 50 ksi; Shall conform with FBC Section 1507.4.3
T-
DRX15001.6 FL17678-R6 Page 2 of 5
This evaluation report is provided for State of Florida product approval under Rule 61 G20�3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality, assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing
DMC 15OSS
Profile:
1.5 in. mechanical seam; Max. 16 in. coverage
Description:
Non-structural, mechanical lock standing seam roof panel
Material:
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 16 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or ASTM A653 G90; Fy = min.
50 ksi; Shall conform with FBC Section 1607.4.3
— r „ all r�
,I
-T
Material: Min. 0.027 in. Zinc; Fy = min. 16 ksi; Shall conform with FBC Section 1507.4.3
L
15.r
DMC 175S
Profile:
1.75 in. snap lock seam; Max. 18 in. coverage
Description:
Non-structural, snap lock standing seam roof panel
Material:
_
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall
conform with FBC Section 1507.4.3
Min. 0.040-inch Fluropon® coated ASTM B209 aluminum (Fy = min. 20 ksi); Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon® coated ASTM A792 AZ50, or
ASTM A653 G90; Fy= min_50 ksi; Shall conform with FBC Section 1507.4.3
1 tj"
L
DMC 200S
Profile:
2 in. mechanical seam; Max. 16 in. coverage
Description:
Non-structural, mechanical lock standing seam roof panel
Material:
Min. 0.040 in. Fluropon@ coated ASTM B209 aluminum; Fy = min. 20 ksi; Shall
conform with FBC Section 1507.4.3
Min. 24 ga. Fluropon@ coated ASTM A792 AZ50, or
ASTM A653 G90; Fy = min. 50 ksi; Shall conform with FBC Section 1507A.3
e a
I 18. I
This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
DREXEL METALS, INC.
Metal Roofing
DMC 450
Profile:
1.5 in. snap lock seam; Max. 16 in. coverage
Description:
Non-structural, snap lock standing seam roof panel with concealed clip
Material:
Min. 24 ga. ASTM A792 or ASTM A653; Fy = min. 50 ksi; Shall conform with FBC
Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 24 ksi; Shall
conform with FBC Section 1507.4.3
16"
DMC 5V
Profile:
3/8 in.ribs; Min. 21 in., Max. 24 in. coverage
Description:
Non-structural, through fastened roof panel
Material:
Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 50 ksi;
Shall conform with FBC Section 1507.4.3
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 23 ksi; Shall
conform with FBC Section 1507.4.3
21" up to 24' Coverage
e
DMC
Profile:
1/2 in. corrugation; 21 in. coverage
Corrugated
Description:
Non-structural, through fastened roof panel
Material:
Min. 26 ga. Fluropon® coated ASTM A792 or ASTM A653 G90 ; Fy = min. 40 ksi;
Shall conform with FBC Section 1507.4.3
_
Min. 0.032 in. Fluropon® coated ASTM B209 aluminum; Fy = min. 19 ksi; Shall
conform with FBC Section 1507.4.3
2,_lTg
DRX15001.6 FL17678-R6 Page 4 of 5
This evaluation report Is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
LIMITATIONS
DREXEL METALS, INC.
Metal Roofing
1. Fire classification is not within the scope of this evaluation.
2. This report is not for use in the HVHZ.
3. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
4. Roof slope shall be in accordance with FBC Section 1507.4.2.
5. Reroofing shall be in accordance with FBC Section 1511.
6. Installations of the evaluated products shall comply with this report, the FBC and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
7. All products listed in this report shall be manufactured under a quality assurance program in compliance with
Rule 61G20-3.
COMPLIANCE STATEMENT
The products evaluated herein by Zachary R. Priest, P.E.
have demonstrated compliance with the Florida Building
Code, 6� Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
P�2018.10.09
.``%,QC'� C
No 74021 _
11:21:46
_041001
%� STATE OF
O 41
�'�,< O R I O P
Zachary R. Priest, P.E.
Florida�`�
21
1 1l Al
Organization No. ANE9641
CERTIFICATION OF INDEPENDENCE
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entityinvolved in the approval process of the
product.
APPENDICES
1) APPENDIX A —installation (12pages)
2) APPENDIX B —Approved Roof Systems (8 pages)
3) APPENDIX C —Design Wind Loads (4 pages)
DRX15001.6 FL17678-R6 Page 5 of 5
This evaluation report is provided for Stale of Florida product approval under Rule 61 G20.3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
®CREEK
TECHNICAL SERVICES, LLC
APPROVED ROOF SYSTEMS
DREXEL METALS, INC.
Metal Roofing
APPENDIX B
The following notes shall be observed when using the assembly tables below.
1. Maximum Design Pressure (MDP) was calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to UMITATIONs and sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated for the selected assembly.
4. The on -center (o.c.) spacing given is the maximum allowable attachment spacing for the rated system.
5. Steel Deck shall be designed by others in accordance with FBC requirements and shall be minimum 22 ga (Fy = min.33 ksi) Wide Rib Deck (Type WR)
conforming to ANSI/SDI-RD1.0 6 FBC.
6. Wood Deck shall be designed by others in accordance with FBC requirements and shall be minimum 15/32-inch thick APA Span -Rated plywood
.sheathing at maximum 24-inch span.
.Roof System Numbers and Definitions
100NS-W#
DMC 100NS over Wood Deck New or Existing)
150SL-W#
DMC 150SL over Wood Deck New or Existing)
150SS-S#
DMC 150SS over Steel Deck New or Existing)
150SS-W#
DMC 150SS over Wood Deck New or Existing)
175S-S#
DMC 1755 over Steel Deck New or Existing)
175S-W#
DMC 175S over Wood Deck new or Existing)
200SS#
DMC 200S over Steel Deck New or Existing)
200S-W#
DMC 2005 over Wood Deck New or Existing)
450-W#
DMC 450 over Wood Deck New or Existing)
SV-W#
DMC 5V over Wood Deck New or Existing)
COR-W#
I DMC Corrugated over Wood Deck New or Existing)
' - Approved Systems for DMC 100NS over Wood' Deck (New or Existing)
System
No.
:Deck
Fire Barrier
Underlayment
-
Roof Panel
Panel Attachment
.. -
-MDP
(Pat)
100NS-W1
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 100NS
DMC 100NS Standard attachment
-97.5
CDX plywood
Versashield Solo
Max. 16-inch wide
with fastener spaced 10.5 in. o.c.
'DONS.-NF2
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 100NS
DMC 100NS Standard attachment
CDX plywood
Versashield Solo
Max. 16-inch wide
with fasteners spaced 5.25 in. o.c.
100NS-W3
Min. 15/32
OPTIONAL
As required per FBC
24 ga. DMC 100NS
DMC f00NS Enhanced attachment
-135
CDX plywood
Versashield Solo
Max. 16-inch wide
with fasteners spaced 6.25 in. o.c.
FL17678-R6
1 of 8
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or
quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other
product attributes that are not specifically addressed herein.