HomeMy WebLinkAboutREVISION - BUILDING PERMITOFFICE USE ONLY: FILE COPY DATE FILED: \ ` `0rr1 ,� PERM[T # REVISION FEE: , `P 3 RECEIPT # PLANNING & DEVELOPMENT SERVICES SCANNED BUDDING & CODE REGULATION DIVISION BY 2300 VIRGINIA AVENUE St. Lucie County FORT PIERCE, FL 34982-5652 (772)462-1553 RECEIVED APPLICATION FOR BUILDING PERM REVIS PROJECT INFORMATION 1 0 L' ; ST. Lucie County, Permitting LOCATION/SITE ADDRESS: 5711 Raintree Trail Fort Pierce FL 34982 DETAILED DESCRIPTION OF PROJECT REVISIONS: Change scope from shingle roof system to metal roof system. Install Owens Coming Titanium Undedayment and 26GA 5V Crimp metal roof system. Replace existing skylight with same. CONTRACTOR INFORMATION: STATE of FL REGJCERT. #: CCC1330816 ST. LUCIE CO CERT. #: BUSINESS NAME: St Lude Roofing INc QUALIFIERS NAME: Jeffrey Hampson ADDRESS: 1913 SW south Macedo Blvd CM: Port St Lucie STATE: FL Z[P: 34984 PHONE (DAYTIME): 772344-7193 FAX: 772-207-7354 OWNER/BUILDER INFORMATION: Q1:\TIC /:\ JI 77F.S3 CITY: STATE: ZIP: PHONE (DAYTIME: FAX: ARCHITECT/ENGINEER INFORMATION: NAME: ADDRESS: CITY: STATE: ZIP: PHONE (DAYTIME): 1ZMA I 07fil 1 �" 4/9/2019 Florida Building Code Online Produd Aonrwal Menu>PmdI orlinofotw Se "> Applloaon list>ApplimUenreran FL # Application Type Code Version Application Status Comments Archived Product Manufacturer Address/Phone/Email Authorized Signature Technical Representative Address/Phone/Email Quality Assurance Representative Address/Phone/Email Category Subcategory Compliance Method FL11602-R7 Revision 2017 Approved BY.�U St. Lucie County APR 10 :'..i ST. Lucie County, Permitting Owens Coming Roofing and Asphalt, LLC One Owens Coming Parkway Toledo, OH 43645 (740) 321-6345 Greg.Keeler@owenscoming.rom Keeler Greg Gmg.Keeler@owenscoming.com Greg Keeler 2790 Columbus Road Granville, OH 43023 (740)321-6345 greg.keeler@owenscomi ng.com Roofing Underiayments Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer ._ 7 Evaluation Report - Hardcopy Received Florida Engineer or Architect Name who developed the Robert Nteminen Evaluation Report Florida License PE-59166 Quality Assurance Entity Intertek Testing Services NA, Inc - QA Entity Quality Assurance Contract Expiration Date 12/31/2020 Validated By John W. Knezevich, PE Validation Checklist - Hardcopy Received Certificate of Independence Referenced Standard and Year (of Standard) Equivalence of Product Standards Certified By FL11602 R7 COI 2018 01 COI NIEMINEN.p Standard ASTM D1970 ASTM D226 (physicals) ASTM D4798 FRSA/TRI April 2012 TAS 117(B) Year 2015 2009 2011 2012 1995 httpsJ/8oridabuilding.orWpripr app dti.aspx?param=wGEVXQwtDgsQFc5Kp/.2frrZeHYB7UGe5KMr5ErnR4gtpLet7gKPIfiBaeQ-/.3dp/pad 112 4912019 Sermons from the Code Florida Building Code Online Product Approval Method Date Submitted Date Validated Date Pending FBC Approval Date Approved Summary of Products Method 1 Option D 08/16/2018 10/08/2018 08/23/2018 10/18/2018 FL # Model, Number or Name Description 11602.1 Titanium Roof Undedayments Synthetic sheet -type roof underlayments Limits of Use Installation Instructions Approved for use in HVHZ: No FL11602 R7 11 2018 09 FINAL2 ER OWENS Approved for use outside HVHZ. Yes CORNING F1.11602-117.odf Impact Resistant: N/A Verified By: Robert Nieminen PE-S9166 Design Pnssure: +N/A(-45 Created by Independent Third Party: Yes Other: 1.) The design pressure noted herein pertains to use of Evaluation Reports a specific undedayment system beneath foam -on file sytsems. FJ11602 R7 AE 2018 09 FINAL2 ER OWENS Refer to ER Section 5.6.3 for details. 2.) Refer to ER Sections 5 CORNING FL31602-R7.ndf and 6 for other Limits of Use. I Created by Independent Third Party: Yes Back Nert r U Us :: 203 6hir Stine Road, Tallahassee FL M399 Phone: 850-487-1824 The state of Florida is an I VEEO employer. rawriaM 2007-2013 Sbbe of norida.:: to .. AEI W Sbriamp rt :- RK W St nn Wrier Florida law, ema0 addresses are pub& remrds. If you do not waft your e-Ma0 addrew released In resporee W a Wblk r rds request, do not send et m r lc mail W Mk entty. Instead, o:nbR Me off-" by phone mby tradRbwl malt. If you have arty questions, please mnmet 850.487.1395.'P nt W Sendlon 455.2MI), Florida State , elrenYlve OGober 1, 2012, fimvoe¢ licensed under Clwpmr455, FS. must pmvtde the Depadment Huh an arms address if they have are. The erruils provided may be used for off d cnnmrmiadon wah Me liarwee. However mall addm;sas are pudic record. If yw do Flat w W supply a primal addrev pl e provide the DepaMrent w M an mwl address which can be made available W the Wblic To determine if you are a floensee under Chapter 455, FS., Pease cK& her . t ?Cl Url tN m I-I-RIC.s httpslffia4dabuildng.orgfpr/pr app_rill.aspx?param=wGEVXQwtDgsOFc5KOlo2frrZeHYB7UCe5KMr5EmR4gtpLet7gKPlflBaeQo.*M%3d 212 SCANNED NEMO I etc. BY Certificate of Authorization N32455 St. Lucie County 353 Christian Street, Unit813 Oxford, CT 06478 (203) 262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY EVALUATION•• Owens Corning Roofing and Asphalt, LLC Evaluation Report 111980.11.09-RS One Owens Corning Parkway FL11602-R7 Toledo, OH 43659 Date of Issuance:11/03/I009 (740) 321-634S Revision 8: 09/14/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida_ The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Titanium"' Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOietc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO i etc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPErnON: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 7 Prepared b Y� P y -y ..n; aau MM Robert J.M. Nieminen, P.E. g Y vi The racgrule seat appearngwasaud�oraedbyRoben Florida Registration No_59166, Florida DCAANE1983 Nieminen,PZ on 09114/201& This does natserve as an eleUronicaHys%ned dmanent. COmnrATION OF INDEPENDENCE: I. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product S. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E.are, in anyway, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. ONEMO etc. ROOFING COMPONENT EVALUATION: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Titanium"' Roof Underiayments, as produced by Owens Coming Roofing and Asphalt, LLC, have demonstrated compliance with the intent of the following sections of the 6'h Edition (2017) Florida Building Code through testing in accordance with appricable sections the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Prop Stanard year 1507.1.1, R905.1.1 Exception Unrolling, Breaking Strength, Pliability ASTM D226 2009 1507.1.1, R905.1.1 Exception Tear Strength ASTM D1970 2015 1507.1.1, T1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 TAS 110 Accelerated Weathering ASTM D4798 2011 TAS S10 Pull -through resistance TAS 117(B) 1995 E Examination Reference bate` ERD 0ST6049) Physical Properties 115010.04.09 04/29/2009 ERD (TST6049) Physical Properties 115010.05.10 05/14/2010 ERD (TST6049) Physical Properties 135520.06.11 05/15/2011 ERD (TST6049) ASTM D226 138010.08.11 08/11/2011 ERD (TSr6049) Wind Uplift 135520.08.11-1 09/12/2011 ITS(TST1509) ASTM D226 311801000Q-003 04/26/2007 ITS OST1509) ASTM D226 3130639COQ-002A 08/21/2007 ITS (IST1509) Physical Properties 3126617COCI-WS 10/31/2007 ITS(TST1509) ASTM D226 101823107COQ-011 01/23/2015 Owens Coming Product equivalency Declaration 06/18/2018 PRI (TST5878) ASTM D1970 OCF-341-02-01 09/20/2017 PRI(TSTS878) ASTM D1970; Tear strength OCF-331-02-02 10/03/2017 PRI (TST5878) ASTM D1970; Tear strength OCF332-02-02 10/03/2017 PRI OSTS8781 ASTM D1970; Tear strength OCF-334-02-02 10/03/2017 PRI (TST5878) FRSA/TRI April 2012 (04-12), partial OCF-343-02-01 11/09/2017 PRI (TST5878) ASTM D4798 OCF-341-02-01 IV27/2017 PRI (TST5878) TAS 117(8); Pull -through DCF-422-02-02 04/03/2018 PRI [TST5878) FRSA/rRI April 2012 (04-12), partial OCF425-02-01 09/13/2018 ITS (QUA1673) Quality Control ITS listings Current ITS (QUA1673) Quality Control Service Confirmation 09/30/2017 4. PRODUCT DESCRIPTION: 4.1 Self -Adhering Underiayments: 4.1.1 Titaniumn' PSU-30 is an unreinforced polymer modified bitumen material adhered to the underside of a polymer - coated, synthetic woven sheet. The underside is backed with a release film. Unit weight 24 Ibs/square. Meets ASTM D1970 and FRSA/TRI April 2012. NEMO ETC, LLC Evaluation Report 111980AL08403 Certificate of Autflor=ffon#32455 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R7 Titanium RooWnderlaymems Revision & 09/14/Z018 Page 2 of 7 ONEMOletc. 4.2 Mechanically Fastened Underlayments: 4.2.1 TitaniumTM UDL-25 is a synthetic sheet -type underlayment comprised of a woven core coated on one side with a polymer coating. Unit weight 2.5 lbs./square; meets FBC 1507.1.1 & R905.1.1(Exception). 4.2.2 Tdanium' UDL-30 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.0 lbs./square; meets FBC 1507.1.1 & R905.1.1(Exception). 4.2.3 Titanium"' UDL-50 is a synthetic sheet -type underlayment comprised of a woven core coated on both sides with a polymer coating. Unit weight 4.7 lbs./square; meets FBC 1507.1.1 & R905.1.1(Exception). 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Titanium' Roof Underlayments may he used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS ASPHALT :' WOOD SHAKES' UNDERLAYMENT - SHINGLES NAI40NTILIE 'FOAM-ONTILE METAL &SHINGLES SLATE Titanium PSU-30 Yes (Dubai, UAE) yes Yes (See 5.5.1) Yes Yes Yes Titanium PSU-30 (Brentwood, NH) Yes Yes No Yes Yes Yes Titanium UDL-25 Yes No No Yes Yes Yes Yes Yes Titanium UDL-30 Yes (a She h2pir (a She m2piy Yes Yes Yes system) system) Titanium UDL-50 Yes No No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of following Approved the adhesives / underlayment combinations. 'Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product ApprovalforOvertuming Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 111980.1L08-RS a"Jk teofAutho ulwn a32455 61° EDITION (2017) FBC NON-HVHZ EVALUATION FL11602-R7 Titanium Roof Underlayments Revision 8: 09/24/2018 Page 3 of 7 ONEMOletc. 5.6 Allowable Substrates: Titanium PSU-30: 5.6.1 Direct -Bond to Deck: ➢ New untreated plywood; ➢ Existing untreated plywood, primed as needed with D41 primer to achieve bond. 5.6.2 Bond to Mechanically Attached Base Sheet: ➢ ASTM D226, Type 1 or II felt. ➢ Titanium UDL-30 (primed with D41 primer) or UDL-30 (inverted). 5.6.3 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on the systems, where the underlayment farms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Referto FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or FBC 1609 for determination of design wind loads. #1 Maximum Design Pressure=-45 psf: Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 Underlayment: One or two plies, Titanium PSU-30 (Dubai, UAE), self -adhered and back -nailed max. 12" o.c in accordance with Owens Coming Roofing and Asphalt LLC published installation requirements. #2 Maximum Design Pressure =-30osf': Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32ga, 1-5/8" diameter tin caps Spacing: 6-inch o.c. at 4-inch wide side laps and 12-inch o.c. at three (3), equally spaced center rows. Primer: ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max- 12" o.c. in accordance with Owens Corning Roofing and Asphalt LLC published installation requirements. #3 Maximum Design Pressure=-30 pstx: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16Anch with min. 32 ga, 1-5/8" diameter tin caps. Spacing: 64nch o.c. at 4-inch wide side laps and 12-inch o.c at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed max. 12" o.c. in accordance with Owens Coming Roofing and Asphalt LLC published installation requirements. NEMO ETC, LLC Evaluation Report 111980.1L08-RB Cerhfficate afAuthoMabdn#32455 6m EDITION (2017) FBC NON-HVRZ EVALUATION FL11602-R1 Titanium Roof Undedayments Revision a: 09/14/2018 Page 4 of ONEMO etc. #4 Maximum Design Pressure=-45 psf•: Deck: Min. 15/324nch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (inverted) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga, 1-5/8" diameter tin caps Spacing: 6-inch o.c. at4-inch wide side laps and 8-inch o.c. at three (3), equally spaced center rows. Primer., ASTM D41 primer required at all tin -caps. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o.c. in accordance with Owens Corning Roofing and Asphalt, LLC published installation requirements. #5 Maximum Design Pressure= -45 psf': Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Titanium UDL-30 (printed side up) Fasteners: 12 ga. annular ring shank nails having not less than 20 rings per inch, heads not less than 3/8 inch diameter and length sufficient to penetrate through the thickness of deck not less than 3/16-inch with min. 32 ga, 1-5/8" diameter tin caps. Spacing: 6-inch o.c. at4-inch wide side laps and 8-inch o.c_ at three (3), equally spaced center rows. Primer: ASTM D41 primer required over printed side of UDL-30. Underlayment: One or two plies, Titanium PSU 30 (Dubai, UAE), self -adhered and back -nailed 12" o.c. in accordance with Owens Coming Roofing and Asphalt, LLC published installation requirements. 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117_ Assemblies marked with an asterisk' carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Titanium UDL-25, Titanium UDL-30 orTitaniumUDL-50 shall not be left exposed for longer than 30-days. Titanium PSU-30 shall not be left exposed for longer than 180-days. 5.8 Tile Slippage Limitations [per FRSA/TRI April 2012 (04-1211: When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. Titanium PSU-30 (Dubai, UAE) Flat Max.10-tile stack 5:12 Lugged Max. 10-tile stack 6:12 Titanium PSU-30 (Brentwood, NH) Tiles shall be loaded and staged atop battens, regardless of tile profile or slope NEMO ETC, LLC Evaluation Report 111MAL08-M Certfimte of AuthcaWhon#32455 6- EDITION (2017) F8C NON-HVH2 EVALUATION FL316D2-R7 Titanium Roof Underlayments Reu"WM S-09/14/2028 Page 5 oF7 NNEW10 et c. c 6.1 Titanium Roof Underlayments shall be installed in accordance with Owens Coming Roofing and Asphak, LLC published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate (if appliable)- 6.3 Titanium" UDL-25, Titanium UDL-30 or Titanium UDL-50: - 6.3.1 Shall be installed in compliance with the requirements for ASTM D226, Type I or II underlayment in FBC Table 1507.1.1 or R905.1.1 for the type of prepared roof covering to be installed, considering the wider sheet -width. 6.3.2 Fasteners: Mechanical attachment of Titanium UDL-25 and Titanium UDL-30 is limited to ring shank roofing nails with minimum 1-inch diameter plastic caps. Mechanical attachment of Titanium UDL-50 is limited to ring shank roofing nails with minimum 3/8-inch diameter heads; ring shank roofing nails with minimum 1-inch diameter plastic caps; screws and plates; or plastic cap staples. 6.3.2.1 Code Reference: The Exception statement in FBC 1507.1.1 and FBC R905.1.1 states: '...except metal cop noilssholl be required where the ultimate design wind speed, V.' equals or exceeds 150 mph." Owens Coming Roofing and Asphalt, LLC has furnished data to permit the use of 1-inch diameter plastic cap nails in lieu of metal cap nails for these applications, when the Titanium" UDL-25, Titanium UDL-30 or Titanium UDL- 50 underlayment is installed beneath mechanically fastened prepared roof covers referenced in FBC Table 1507.1.1 or R905.1.1. 6.3.3 Slopes of 4:12 or ereater: End (vertical) laps shall be minimum 6-inches and side (horizontal) laps shall be minimum 4 inches. Minimum attachment shall be in accordance with FBC Table 1507.1.1 or R905.1.1. When batten systems are to be installed atop the underlayment, the underlayment need only be preliminarily attached pending attachment of the battens. 6.3.4 Slopes of 2:12 to less than 4:12: Double layer application; begin by fastening a 25-inch wide strip along the eaves. Place a full -width sheet over the starter, completely overlapping the starter course- Continue as noted in 6.3.3, but maintaining minimum 25-inch side (horizontal) laps, resulting in a double -layer application - GA Titaniumfl' PSU-30: 6.4.1 Non -Tile Installations: Shall be installed in compliance with the codified requirements for ASTM 01970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed, and Owens Coming published requirements. Titanium'" PSU-30 shall be back -nailed max.12" o.c. in accordance with Owens Coming Roofing and Asphalt, LLC published installation requirements. 6.4.2 Tile Applications: Shall be installed in compliance with the requirements for Self -Adhered Membrane underlayment set forth in FRSA/TRI April2012 (04-12), and Owens Corning published requirements. Titanium"' PSU-30 shall be back -nailed max.12" o.c. in accordance with Owens Coming Roofing and Asphalt, LLC published installation requirements. Tile shall be loaded and staged in a manner that prevents the slippage and/ordamage to the underlayment Refer to Table 2 herein, and Owens Coming Roofing and Asphalt LLC published requirements fortile staging. NEMO ETC, LLC EvaluaBon Report 111980.2L08-RS Certfico[e ofAuVw=Wm d32455 a EDmON (2017) FBC NON-HVHZ EVALUATION FLU602-R7 Titanium Roof Undedayments Revision 8: 09/14/2018 Page 6 of 7 ONEMO etc. 6.5 Titanium 2-PIy System: 65.1 The Titanium 2-Ply System consists of a base layer of Titanium UDL-30 (top -surface primed or sheet inverted) mechanically attached to the wood roof deck followed by Titanium PSU-30, self -adhered. 6.5.2 Non -Tile Applications: Install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with Section 6.3 followed by Titanium PSU-30 in accordance with Section 6.4. 65.3 Tile Applications: For nail -on the installations, install Titanium UDL-30 (top surface primed or sheet inverted) in accordance with FRSA/TRI April 2012 (04-12), using Section 6.3 as a guide, and considering the wider sheet width relative to ASTM D226 felt. Then apply Titanium PSU-30 in accordance with Section 6.4. For adhesive -set file roofing, refer to Section 5.6.3 herein. Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. Refer to Table 2 herein, and Owens Coming Roofing and Asphalt, LLC published requirements for tile staging. As required by the Building Official or Authority Having J urisdiction in order to this product. Contact the noted QA agency for information on product locations covered for F.A.C. 631520-3 CIA requirements. The following plants have qualified products under their respective physical properties specifications. Plant; ' 5pg4 cation Produ' s Mission, BC, Canada FBC 1507.1.1(Exception) Titanium UDL-30; Titanium UDL-50 Qingdao, China FBC 1507.11(Exception) Titanium UDL-25; Titanium UDL-30; Titanium UDL-50 Dubai, UAE FRSA/FRI 04-12 (2-ply system) Titanium PSU-30 (Dubai, UAE) Brentwood, NH ASTM D1970, FRSA/rR104-12 Titanium PSU-30 (Breatwood, NH) QUALITY9. Intertek Testing Services NA Inc.—QUA1673; (604) 520-3321 -END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report 111980AL08-R8 OutrflWe OfAunefaiWon 432455 6- EDmON (Z017) FBC NON-HVHZ EVALUATION FL3360Z-R7 Titanium Roof Uldedayments Revision 8: 09/14/2018 Page 7 of 7 RECEIVED APR 10 ?01g i ST. Lucie County, Permitting 4 ��1 Im SCANNED BY St. Lucie County Palm City, FL 34990 Compliant with Florida Building Code 2017 (6tl' ed.) Compliant with Florida Product Approval Rule # 611320-3 Compliant: Keystone Certifications Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2 Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood Deck w/ min. 0.42 specific gravity with screws. 24" Coverage Rib Height 3/8" Corrosion Resistant Compliant: FBC Sec.1507.4.3 Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet requirements) Underlayment: To be compliant with FBC Sec. Chart 1507.1.1 Slope: Shall be in compliance with FBC Sec.1507. See Fastener attachment specifications above Install Details: Table A ' Allowable, Loads METHOD 1 ----- - METHOD 2 ----- -- METHOD.3 _ METHOD 4 DESIGN PRESSURE* -86 PSF -93.5 PSF -101 PSF -228 PSF ROW SPACING . ... _ 16" ax. _ _ 16" o.c.., 8" O.C. 6" o.c. FASTENER SPACING (ALONG Panel width) , _ 12" o.c. _12" o.c. _ _ 12" o.c. 12" o.c. FASTENER SIZE #9 #10 #10 #10 Reference Data: ARCHITECTURAL TESTING, INC. TST ID#:1527 UL 580-06 & 1897-041 Test Report 016893.01-450-18 05/02/14 Test Report F3366.01-450-18 11/18/15 TAS 125-03 Test Report D05893.02-450-18 07/22/14 *EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-Irf I II t *Design pressure margin of safety 2:1 �C.O .F Locke Bowden, P.E. does not have, not will acquire a financial int lh a �cq 4ym,9iyfacturing or distributing products under this evaluation. Locke Bowden, P.E. is not owned, operated, or controlled by a& coonpadypmbb3f9tures, or distributing products under this report. a ,C : /' ; . a "..9 N FL17O22.1 5V Crimp (26GA Steel), 24" Wide Roof Panel - Details Limitations: 1. Uhderlayment to be compliance with current Florida Building Code (FBC)2017 6th ed. 2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference. 3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-13 4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers. 5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report. 6. Support framing in compliance w/FBC 2017 61h ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for Structural Loading. 7. This report does not imply warranty, installation, recommended product use outside of this report. — Fasteners - #9.1-12"Min. or #10 " 1-12" Min. pwTable A' rorRow 5-V Dimp Roof Panel Spacing and Design Pressures Hex Washer Head Wood screws Deck: -15132" agreater Plywood, a - Wood plank 24" 12' 30 Panel Overlap Panel Profile Nominal12" Nominal12" O.C. o.c. Fasten g x -1/2" Min. or #10 x 1-112" Min. per Table "A" Hex Washer Head Screw Spaced 12" o.c. across the Panel Width Refer to Table "A" for Spacing Along Panel Length Deck-15/32" or greater Plywood, or -Wood plank RECE1Vty p k 10 '19 5T. Lucie CounC tYe Pew slyw l—rwrlti.e,.rrrw.wl me.+l+mlo-a+u.l ---I —I —IY r Approval AProduct II usEx:pwucuser Pmauttlearned > ape ,t of aolllcodbrSyr> sochrobon I sr >Appllwtlon Detail R2418 R11 tip sn'r Revision Mir M sonemn Approved •Approved by DEPa Appmals W Deal van be mylewea earatelea W the fail t.WW tem mmm .If rccessar, m O W.Im industries, In . alumormm./an.r 1630 here colors Gun Derr, T%1531i-Mil Wa®matlmskyllpa6.mm ew. Iarfnss David Thee. IhmQmacimd,bgmy.mm ,_.mso— �_r a� rmae.r Sw lights comepn Skylight Onsal—aysnd cemfimuon run dr i-cond onflosessaumn xaCgnal Acoealuuse vemmn xaaaw AcgmmuaawannagemmmemMa onne wtltun —.sn,m.e..an-wemw,m aum.m xr.e No his is. aga..w�wr,sa,mswmm by FlMda 11¢rted Rvfe¢9ow Enplrcer or A:Wte¢ n5y n rnaua µs•nY xew Method l Option Duclussucall 031OW2018 03/MMI8 c Amup oa.A+prosa D3/Dp/$O1E SuNRma of PZDtiuptg ', .. ., •`.' ^. ,� ,.. oevnpnet, ". - n.. xmraaublosr. .e -ollso Pfa: yyelnwn onate Glast be54upnl sWfcuawux s�PoM� .[he. Age:q cemmml. umltsofuae ApptouM Nor use In HwZ: yes Jodi Apromsed her useeuGWy NVNZ: Yee Ihmm, Assuranu font. FvplraNim gate impxlhowshanu Yes IV31/ZOSt .1, Pressure: +EOy.E3 Imeallauon lo-tru¢bns ONO, Vmfied BY: Robert J. AmonsonFe R iE No.r 4WO thatM by Independent TNN Party: Yes Evaluation Reports ]aee ail no pely,oca puny, g; n M Cma Oeatea by 1Mepenaen[3hIN Party: Yes z.u.z saw'osroeSnfroury5e _ sM'am fdycalbONte G13RY uwnlnuT skyngnt , _ i - elmllsoff.. e¢nX Mo Agenq feNfcate Approved Mr use In u V NL Yes WereaMNwuseausaWa MVNLYec QualltY Aseu:arm contract esprauan plane empatRdstink Yei l3/3V2021 gO1gm once rtd +W-w enMlYch-leiM1u¢IOn. gNa prool bcm� r", � net . Venfiea patent, . Mmn6e.1£ R IE. MM - - + ombea by uwepanaem-mbe Pa,: Yes evzlualbn Reports n.Rei ec p[p]rXYe Rav]aIP. Ot .N e by 1,, mi.n geale0wece:iaeR TNN peM:Yei E.IX Inert (yD[EQV5:: 26n[PJah Srene Rnanl. TnRnFnameR3gq phnnePefl<A Tire irate of Malda Is an WEF0 amployea "m ]npv]nta Emm of Poll :: "No" Smhm^ent:: Pblllly ct ., R.firnd"Is was lroaaa law, emau edWeeal are public retsNs. if you tip not want your e-mail address relaaM In msponu to a pabllcre¢Ns request, do not send decomNe mall to this many. handead, tmmO the ohl by phone or by traditional mall. If you have any questions, please cmmQ ecn 487 I age, *pursuant m RNon 455.275(I), Flmlde Statutes, eaective Webb, lr ' Nlli,lcomeees Gtvtsed under Oohm"55, F.S. muse provide the Department Mth an small addrta a they have one, Tile emalls plovlded mey be used for officialNm blue canmumawith e Ilee:lse. mmayer emNl addresses art public needed. If you do not arsh he supply a personal address, please prwlde the Department with an email address wNdt on be made available to the publlc To detemilne If you are a licensee under Gapter 455, FS., please tlIIX all product APPMal Accepts: 00®®G oeatcad Sa/a SCANNED BY St. Lucie County MAXIM INDUSTRIES, INC. SERIES "DCM" DADE CURB MOUNT SKYLIGHT INSTALLATION ANCHORAGE DETAILS GENERAL NOTES: INSTALLATION NOTES: 1. THIS PRODUCT IS DESIGNED TO COMPLY WITH THE HIGH 1.ONE (1) INSTALLATION ANCHOR IS REQUIRED AT EACH VELOCITY HURRICANE ZONE(HVHZ) OF THE CURRENT ANCHOR LOCATION SHOWN. EDITION OF THE FLORIDA BUILDING CODE (FBC). THE PRODUCT DETAILS CONTAINED HEREIN ARE BASED UPON 2. THE NUMBER OF INSTALLATION ANCHORS DEPICTED ARE SIGNEDAND SEALEOTESTREPORTATI01d3381.01AND THE MINIMUM NUMBER OF ANCHORS TO BE USED FOR ASSOCIATED LABORATORY DRAWINGS, PRODUCT INSTALLATION. . 2. ADEQUACY OF THE EXISTING STRUCTURAL FRAMING AS A 3. FOR INSTALLATION INTO WOOD ROOF DECK, USE 012 MAIN WIND FORCE RESISTING SYSTEM CAPABLE OF WOOD SCREWS OF SUFFICIENT LENGTH TO ACHIEVE 1318 WITHSTANDING AND TRANSFERRING APPLIED PRODUCT INCH MINIMUM EMBEDMENT. MINIMUM EDGE DISTANCE IS LOADS TO THE STRUCTURE IS THE RESPONSIBILITY OF THE 11NCH. ENGINEER ORARCHITECT OF RECORD. ' 4. MINIMUM EMBEDMENTAND EDGE DISTANCE EXCLUDE 3.IN AREAS WHERE WIND-BORNE DEBRIS PROTECTION WALL FINISHES, INCLUDING BUT NOT LIMITED TO REQUIREMENTS EXIST USE OF AN APPROVED IMPACT STUCCO, FOAM, BRICK VENEER AND SIDING. PROTECTIVE SYSTEM IS NOT REQUIRED. 5. INSTALLATION ANCHORS SHALL BE INSTALLED IN 4. MATERALS: ACCORDANCE WITH ANCHOR MANUFACTURER'S 4.1. SKYLIGHTFRAME:8083-T6EXTRUDEDALUMINUM. INSTALLATION INSTRUCTIONS AND ANCHORS SHALL 4.2. SKYLIGHT INNERAND OUTER DOME MATERIAL: NOT BE USED IN SUBSTRATES WITH STRENGTHS LESS MAI ROLON POLYCARBONATE BY COVESTRO, LLC PER THAN THE MINIMUM STRENGTH SPECIFIED BY THE CURRENT MIAMIDADE NOA COMPONENT APPROVAL. ANCHOR MANUFACTURER. B. INSTALLATION ANCHOR CAPACITIES FOR PRODUCTS HEREIN ARE BASED ON SUBSTRATE MATERIALS WITH THE FOLLOWING PROPERTIES: A. WOOD - MINIMUM SPECIFIC GRAVITY OF 0.42. 4" MAX. FROM 10.50' MAX. CORNERS TYP. O.C. TVP. L T T T T 4" MAX. FROM T ~ CORNERS TYP. TABLE OF CONTENTS DESIGN PRESSURE RATING(PSF) IMPACTRATING LARGE MISSILE i80A IMPACT SHEET REV. SHEET DESCRIPTION 1 — NOTES, ELEVATION S ANCHOR LAYOUT 2 SECTION VIEWS 10.50" MAX. O.C. TYR 1 1 1 48" MAX. O.A. FIXED D.L.O. WIDTH _ 518" MAX. O.A. CURB WIDTH _ 43" MAX. OA. WIDTH ELEVATION & ANCHOR LAYOUT EXTERIOR VIEW TH -777 4 m w �LL w KF u LL e UW a a ax a a U 0 Q x u� m� �o 3yyu Q yy 1 U.N U'o 4 :O:�oa Ai €�o.ZL m UW Jfd RpYs � 041 y Robed. . P.E. FbMe P..E.C. N.. o.49]6] !Digitally signed by pw RobertJ 10:08:11 -05,00, 1. Minimum #12 fastener by others. Pre -punched installation holes 4" from each corner, maximum 10.5" on center. Minimum penetration=1-3/8". 2. .060" X 1.5" X 1.75" 6063-T6 extruded aluminum retaining angle. Aluminum angle mitered and welded @ four comers. 3. 52.5" X 100.375" UV Enhanced outer Makrolon Polycarbonate Dome by Covestro, LLC @ 8" height on test sample dome height varies per skylight size but not less than the larger of 10% of the dome's span or 4') . 4. 52.5" X 100.375" UV Enhanced inner Makrolon Polycarbonate Dome by Covestro, LLC @ 4" height on test sample ( dome height varies per skylight size but not less than the larger of 10% of the dome's span or 41 . 5. OSI PR256 urethane sealant. Located between aluminum retaining angle and outer dome $ between inner dome and aluminum frame. 6. Sealant tape. 1" X .125" located between outer and inner domes. 7. 6063-T6 extruded aluminum frame. Aluminum frame mitered and welded @ four corners. B. #12 X 1.75" fastener. One fastener located equidistant from each corner. Four fasteners per skylight. 9. #10 X .375 18-8 stainless steel fastener. Located 4" from each comer, maximum 11" on center. 10. All units equal to or less than the total square footage or the test specimen, 36 square feet, will be accepted under this approval. 11. Minimum distance = 4" from angle lip to roof surface for shingles or BUR without insulation. For insulation and file roof add tile height and insulation thickness to the 4" minimum height. O2 .060" Extruded Aluminum,' Retaining Angle OMinimum #12 wood screw with min. 1-3/8" embedment into substrate receiving point. Installation holes 4"� from each comer, maximum 10.5" on center. Design Pressure: 60psf +/- I_ Roof deck and framing by others. All mof details shall comply with _ Chapter 15 of the Current Edition FBC and Chapter 9 of the Current Edition FRC. Outer Polycarbonate Dome O3 Inner Polycarbonate Dome Sealant O Sealant Tape -Sealant O —Condensation Gutter Sealant O 1-3/8"'Min. Embedment Curb Mount Model #12 Stainless Steel Fastener with neoprene gasket. One fastener located equidustant from each ' comer. (Four fasteners per skylight) #10 X .375" stainless steel fastener @ 4" from each corner, maximum 11" 9O on center. 0.060" Aluminum Frame O R.b dj.P ...P.E. RWde P.E.Ne.4WW Digitally signed by €?.4,, RobertJ 10:08:31 -05'00'