Loading...
HomeMy WebLinkAboutPLANS63.98, 18600' 16.Q0 11A� OPEN PATIO 8.00' i �E SCREEN ROOM 4:00 e SHED` .� 12.00' , �25 33' , U a P ART cn — —-19.00' i MIN. SETBACK REQ. REVIEWED OR MN. CODE COMPLIANCE SIDES CNR S ST. LUCIE COUNTY REA 3267' BOCC , ZNG. TECH, In the event ofa comlictin memh rsizes shown on the plans and the general notes, th utlze fhe more s6 ngent member.,Zn�ctormust Engineer: Michael Thompson, P.E: n 9uuemenls. 7509030930 ...1'0' EASEMENT SCANNED CL�STO,MER BY k St. Lucie County BLOCK: -70 LOT.' 04 PHASE: 08 MODEL.: MINICORAL`REEF SIDLNG COLOR: SIZE 2T X -- 4" ,:. DRAWN BY:_JOHN MANUF: HOMES OF�MERIT DATE::07/11/05 �- 'SCALE: 1" = 1.0' { , n �0 m m � c <_ connm n m 3 m 00Ir„ v >O z Z 10 ,,,< m m T N S S CD m m Q m n• -z rt CD a$ m 3 all posts 3x3 8'-8- I 8-6• shed I ; I , a) I , I I I I I C C I I I O I � I I _0 I � I I (O I U I N I I o I N i 3 C z (0 T (' E 1 , I I I I I �— T i T —� 16, I 14 I T 8'-8• 8'-8• all posts 3x3 T 8 20 eve rail connected to house with 2" rec channel at house(black) secured with (2) y" lapcons and (2) #12 x }" top and bottom 3" poly rommet nel cured to eve rail12" with #14 x 5" SDS with rubber on ery 31--E� 2or�33eve •Eve rail attached to post with 2' rec channel and (2) #12 x 1" into top and bottom and (4) #12 x 1'through channel Into post 3x3 post notched in front to accommodate 2x lap carder beam with %' bolts x 4" through post and beam. 910 x 3f4" through header into panel every e" or 6 per 4' panel no screws on lop 3" 3le" bolts through beam, and post Poly roof connection to wall and house details Ginter braces at each beam 4" wide with (3) #14 x 1" through brace on one side and (3) #14 x 1" Into lip of (6) #10 gutter 3/e" boltbeam, and posh heam, and post 5" supergutler beam screwed to gutter before mating with #10 x 314" at 6" Oc Poly roof to super gutter to enclosure connection details Contractor Alternative Option REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY EOCC In the event of a tanfllct In member sizes shown on the plans and the general notes, the conhactormust utilize the more stringent membe'rrize requirements. Fnginaer: Michael Thompson, P.E. 47509/CA30930 n '.� 0 cm< ponnm 0 Mrn n0�® L M Z 10 m es sh0vM Or' In the event of a cant ai 1110 tiet the�pntrado must the plans and the g uirements- ul1ize the mote stdngeld membef Me 5p91CA30930 Engineer Michael Thompson, P. Poly Roof Attached to beam with Self Drilling Lags #14 @ 18" cc 2x3 or 3x2eve rail Uprights fastened through eve rail with (4) #10 x 2" sheet metal screws 2x uprights (patio) Angle attached to upright with (2) #14 x 1"and into concrete with (1) 3/8' x 4'tapcon MI X 2' sheet metal screws )ugh upright into eve rail each side 2x uprights (lap) Poly roof connection details to post and eve using 2x patio and lap uprights 3" poly panel secured to eve rail with #14 x 5' SDS with rubber grommet on top every 12. OC \ structural Gutter Roof 0 `(2) #10 X 3/4'se# drilling screws through channel into gutter Poly roof connection details to super gutter Contractor Alternative Option I , r 2 0 %' x 4' bolts with nylock nuts 1.5' x 2" receiver channel attaches to house with tapconsA" x 1 W 3' header severed to house(CBS) with Yi tapcons x 1 Y.' long every 18" OC r 3" 3" header o o -J{ r3" r-`-1 Carrier beam Ye' x 4' boltswith nylodk nuts =1--3" In the event ofa conflict in member sizes shown on the plans and the general notes, the contractor must dtitize the more stqngent member,ize require Engineer: Michael Thompson, P.E. 47509/CA3ments. 0930 3" Internal post Insert secured to concrete with (4) x 1 314" tapcons Poly roof post and beam connection details using 3" posts Contractor Alternative Option . REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY BOCC ALUMINUM SCREEN DESIGN ROLL -FORM GUTTER IS ATTACHED TO 3" PAN ROOF WITH # 10 1" 6" FROM ENDS 24" C ROOF IS ATTACHED TO FRONT WALL & SUPPORT BEAM WITH (4) #10 1" PER PAN BEAM TO WALL CONNECTION REVIEWED FOR ;ODE COMPLIANCE ;T. LUCIE COUNTY BOCC 2X2 RECIEVING CHANNEL IS ATTACHED TO BEAM WITH 1 LESS # 10 1" THEN BEAM SIZE & INTO STRUCTURE WITH (4) BRACKET FROM 3X3 IS ATTACHED TO CONCRETE WITH (2) 1/4" X 2" TAPCONS TYP. ((2) 1/4" X 5" TAPCONS IF THRU PAVERS) ((2) #10 2" IF TO WOOD DECK) ALUNII SCREENDESIGMCOM ALUMINUMSCREENDESIGN @YAHOO.COM PHONE: 407-734-1470 FAX: 407-734-1790 3" C CHANNEL IS ATTACHED TO 4TH WALL STRUCTURE WITH #10 1" 6" FROM ENDS 24" O.C. & TO 3" PAN ROOF WITH (4) #10 1" PER PANNEL ROLL FORM FASCIA IS ATTACHED TO PAN ROOF WITH 910 1" 6" FROM ENDS 24" O.C. 3X3 POSTS ARE ATTACHED TO 2X6 BEAM (2) 3/8" X 3 1/2" 3X3 POST IS ATTACHED TO BRACKET WITH (2) 3/8" X 3 DESIGN STATEMENT METAL IS .046 THICKNESS OR GREATER, ALLOY IS 6005-T5 ALL TAPCONS SHALL PROVIDE MINIMUM OF 11/8" CONCRETE EMBEDMENT DEPTH THIS STRUCTURE HAS BEEN DESIGNED IN ACCORDANCE TO MEET THE REQUIREMENTS OF THE 2017 (6TH EDITION) FLORIDA BUILDING CODE FOR OPEN AND SEMI -OPEN STRUCTURES AND SHALL WITH STAND ULTIMATE WIND SPEEDS OF 150 MPH (FOR 3 SECOND GUSTS) NOMINAL SPEED 117 MPH UP TO A 15FT ROOF HEIGHT, FACTOR OF 1.0, AND EXPOSURE C, RISK CATEGORY 1. CONTRACTOR SHALL FIELD VERIFY ALL PLANS DIMENSIONS PRIOR TO MATERIAL PURCHASE, FABRICATION AND CONSTRUCTION CONTRACTOR SHALL NOTIFY THE ENGINEER IMMEDIATELY SHOULD SITE CONDITIONS DIFFER FROM CONSTRUCTION PLANS MICHAEL THOMPSON 4401 VINELAND ROAD SUITE A6 O, FL 32811 • P.E. # 47509 RECEIVED APR 082018 Permitting Department' St. Lucie County