Loading...
HomeMy WebLinkAboutPRODUCT APPROVALFlorida Building Code OnlineR111119, 10:17 AM W.a..�a 's BM Home Lop to User Regb&agon Hot Topics Submit Surcharge Slabs &Facts Publltations ContactUs acts Site Map unkB Search Product Approval I` USER: Public Uwr SCANNED > APPUmdon Detail BY St. Lucie County FL # FL11651-R3 Application Type Revision Code Version 2017 Application Status Approved Comments Amhived Product Manufacturer Gulf Coast Supply & Manufacturing, LLC. Address/Phone/Email 4020 S. W. 449th Street Rlfi Horseshoe Beach, FL 32648 qp9 Fp nfo@9ulfcoastsupply.rnm ps gl`iO 1 �1p1,9 % "Ce C"O. Authorized Signature Eng David P4. nfo@gulfcoastsupply.com Coli4fi °nr Technical Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352)498-0778 info@g ulfceastsu pply.com Quality Assurance Representative David Eng Address/Phone/Email 14429 SW 2nd PI Ste G30 Newberry, FL 32669 (352) 498-0778 david.eng@gulfcoastsupply.com Category Roofing Subcategory Metal Roofing Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer Evaluation Report - Hardoopy Received Florida Engineer or Architect Name who developed Daniel S. Kuhn the Evaluation Report Florida License PE-75519 Quality Assurance Entity Keystone Certifications, Inc. Quality Assurance Contract Expiration Date 04/12/2024 Validated By Locke Bowden P.E. Validation Checklist - Hardcopy Received Certificate of Independence 1 10104, a t https:liw.floridabuilding.org/pr/pr_app_dti.aspx?param=wGEVXQWtDgSQFc5K%2frZeCSHgw99R5wgrf90E �4,y�� % Page 1 of 6 MPLIANCE 'I L 0ST. UCI COUNTY B®CC Florida Building Code Online 4111119, 10:17 AM Referenced Standard and Year (of Standard) Standard Year FM 4471 1992- TAS 100 1995 TAS 110 2000 TAS 125 2003 UL 1897 2012 UL 580 2006 Equivalence of Product Standards Certified By Sections from the Lode Product Approval Method Method 1 Option D Date Submitted 1O/10/2017 Date Validated 10/12/2017 Date Pending FBC Approval 10/17/2017 Date Approved 12/12/2017 Summary of Products Go to Page 0 0 0 Page 1/ 2 ,&3 i FLL� # Model, Number or Name Description _ 111651.1 0.032° Aluminum SV Crimp Min 0.032" 5 V Crimp Aluminum Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No I Approved for use outside HVHZ Yes I Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. Install per manufadvrers Evaluation Reports I details. Not for use in HVHZ Zones. i 4 j Created by Independent Third Party: Yes 111651.2 0.032' Aluminum Gulf Lok Min 0.032" Aluminum Gulf Lok 16' Wide Roof Panel over 15/32° Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes Other: -52.5 psf @ 5 3/16" o.c. fastener spacing. -116.0 psf Evaluation Reports 5 3/16" o.c. fastener spacing. Install per manufacturers )@ Y details. Not for use In HVHZ Zones. Created by Independent Third Party: Yes i 11651.3 1" 24ga. Gulf Snap 1° Gulf Snap 24 Ga. 17" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes r Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-131.OPS Created by Independent Third Party: Yes Other: -67.3 psf @ 24" O.C. dip spacing. -131 psf @ 6" O.C. i Evaluation Reports iii clip spacing. Install per manufacturers details. For use in -HVHZ Zones. i I Created by Independent Third Party: Yes i https:liw .floridabuilding.org/pr/pLapp_dti.aspx?param=wGEVKQWtDgsQFcSK%2fTrZaCSHgw99RSwgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 2 of 6 I I Florida Building Code Online 4111/19, 10:17 AM 11651.4 11' 24ga. Versal-oc 1' VersaLoc 24ga 16.5" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ Yes - h Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-138.SPSF Created by Independent Third Party: Yes I Other: -71 psf@ 24' o.c. clip spacing. -138.5 psf @ 6' O.C. Evaluation Reports IIi1i clip spacing. Install per manufacturers details. For use in HVHZ Zones." `Created by Independent Third Party: Yes - 11651--1" Vem Loc .032" Aluminum. 1" Versal-oc min .032" Aluminum over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes I„ Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-101.0PSF Created by Independent Third Party: Yes 4 Other:-63.3 psf @ 24' o.c. clip spacing. -101.0 psf @ 6" o.c. Evaluation Reports ' clip spacing. Install per manufacturers details. For use in HVHZ Zones. j '- Created by Independent Third Party: Yes 11651.6 1.5' 24ga. Gulf Snap 1.51 Gulf Snap 24ga. 16" Wide Roof Panel over 15/32" Plywood Limits of Use I Installation Instructions Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes ff Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-116.OPSF Created by Independent Third Party: Yes IIII Other: -86.0 psf @ 24" o.c. clip spacing. -108.5 psf @ 12' ! Evaluation Reports o.c. clip spacing. -116.0 psf @ 6" o.c. clip spacing. Install per manufacturers detals. For use in HVHZ Zones. - - Created by Independent Third Party: Yes 11651.7 1.5" 24ga. Versal-oc 1.5" VersaLoc min 24ga. 16" wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions l Approved for use in HVHZ: Yes IIIr Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-123.5PSF Created by Independent Third Party: Yes 1 Other: -59.75 psf @ 24' o.c. clip spacing. -123.5 psf @ 12' Evaluation Reports I o.c, clip spacing. Install per manufacturers details. For use In I HVHZ Zones. 'Created by Independent Third Party: Yes .i 11651r 8 2° 24ga. MegaLoc Min 24 Ga. 2' Megal-oc 18' wide Roof Panel over 15132" Plywood i Limits of Use Installation Instructions Approved for use In HVHZ: No I Ii. Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 1 Design Pressure: +N/A/-108.SPSF Other: -71.0 psf @ 24" O.C. clip spacing. -108.5 psf @ 12" Created by Independent Third Party: Yes Evaluation Reports o.c. clip spacing. Install per manufacturers details. Not for use in HVHZ Zones. { _ Created by Independent Third Party: Yes 11651.9 24 Ga. Gulf Lok Min 24 Ga. Gulf Lok 16" Wide over 15/32' Plywood Limits of Use Installation Instructions Approved for use In HVHZ: No - Approved for use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 1 Design Pressure: +N/A/-96.7PSF Created by Independent Third Party: Yes Other: -81.75 psf @ 10-1/4' o.c. fastener spacing. -96.76 Evaluation Reports psf @ 5-118" O.C. fastener spacing.-121.75 psf @ S-1/8" i fastener spacing. -261 psf @ 5-1/8" fastener spacing. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party: Yes https:llw w.floridabuilding.org/pripr app_dtl.aspxlparam=wGEVXQmDgSQFc5K%2fTrZeCSHgw99RSwgrf9OEegvkzBZ4cWkSTfwnA%3d%3d Page 3 of 6 Florida Building Code Online 4/11/19, 10:17 AM 11651.10 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam 16" Wide Roof Panel over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions i. Approved for use in HVHZ: No t _ Approved for use outside HVHZ: Yes j Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-93.5PSF Created, by Intlependent Third Party: Yes I Other: -93.5 psf @ 18" o.c. Install per manufacturers details. Evaluation Reports Not for use in HVHZ Zones. EU t�^^� �••• -•- --�iS- Created by Intlependent Third Party: Yes i 11651.11 24 Ga. Gulf Seam Min 24 Ga. Gulf Seam, 1 3/4" Snap Lock, 18" Wide Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Et .Approved for use outside HVHZ: Yes gl ' if Impact Resistant: N/A Verified By: Dan Kuhn, RE. 75519 Design Pressure: +N/A/-108.5PSF Created by Independent Third Party: Yes Sr Other: -69.25 psf @ 24" o.c. clip spacing. -108.5 psf @ 12" Evaluation Reports o.c. clip spacing. Install per manufacturers details. Not for use f S 1 in HVHZ Zones • - - "Created by Independent Third Party: Yes 111651.12 126 Ga. 5V Crimp Min 26 Ga. SV Crimp Roof Panel over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: Yes Approvedfor use outside HVHZ: Yes Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-156.SPSF I Created by Independent Third Party: Yes Other. -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ ( Evaluation Reports 6" o.c. fastener spacing. Install per manufacturers details. For , use in HVHZ Zones. 'r Created by Independent Third Party: Yes T- 11651.1� 3 26 Ga. 5V Crimp Min 26 Ga. 5V Crimp over 15/32" Plywood Limits of Use Installation. Instructions I Approved for use in HVHZ: No f' Approved for use outside HVHZ: Yes i '111 Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-131.PSF Created by Independent Third Party: Yes Other: -94.25 psf @ 16" o.c. fastener pattern. -131.0 psf @ Evaluations Reports 16" o.c. fastener pattern. Install per manufacturers details. Not for use in HVHZ Zones. Created by Independent Third Party Yes 11651.14 26 Ga. SV Crimp Min 26 Ga. 5V Crimp Roof Panel over Sk4 Wood.Purlins over 15/32" Plywood Limits of use Installation Instructions j Approved for use in HVHZ: No F I ` Approved for use outside, HVHZ: Yes Impact Resistant: N/A I Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-156.SPSF Created by Independent Third Party: Yes Other: -108.5 psf @ 12" o.c. fastener spacing. -156.5 psf @ Evaluation Reports 6" o.c. fastener spacing. Install per manufacturers details. For use in HVHZ Zones. _ Created by Independent Third Party: Yes i 11651.15 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15/32" Plywood i Limits of Use Installation Instructions Approved for use In HVHZ: Yes - - Approved for use outside HVHZ: Yes r :f Impact Resistant: N/A Verified By: Dan Kuhn, P.E. 75519 Design Pressure: +N/A/-161.OPSF Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c, fastener spacing.-121.75 Evaluation Reports psf @ 5 3/16" spacing. -161.0 psf @ 5 3/16" o.c. fastener t:. , spacing. Install per manufacturers details. For use In HVHZ Zones. Created by Independent Third Party: Yes https://www.flaridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsQFCSK%2fTrZeCSHgw99R5wgrf90EegvkzBZ4cWkSTfwnA%3d%3d Page 4 of 6 Florida Building Code Online 4111119, 10:17 AM 11651.16 26 Ga. Gulf Lok Min 26 Ga. Gulf Lok 16" Wide Roof Panel over 15132" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-63.5PSF Installation Instructions - FL11651 R3 II FL11fi51 16 R3 Metal Roof Panel Detail - signed.odf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Other: -63.5 psf @ 5 3/16" o.c. fastener spacing.-121.75 psf @ 5 3/16" fastener spacing. -161 psf @ 5 3/16" fastener Evaluation Reports F111651 R3 AE FL11651 16 R3 Mulfbok 16 15- 32Plywood NonHVHZ-Sj9ned.Ddf Created by independent Third Party: Yes spacing. Install per manufacturers details. Not for use in HVHZ Zones. I 11651.17 26 Ga. GuIfPBR Min 26 Ga. Gulf PBR Roof Panel over 15/32" Plywood Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-154.7PSF 'Other: -59.25 psf @ 24" o.c. fastener pattern.-154.75 psf @ 12" o.c. fastener pattern. Install per manufacturer details. Not for use in HVHZ I Installation Instructions FL11651 R3 II FL11651 17 R3 etal Rn Panel Detali- sianetl ndf Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports ^, T FLi1651 R3-6-F_t(f1_" ^^ 32FIyv ood Non4Vi "-_ '- ' Ud Created by Independent Third Party: Yes 11651.18 26 Ga. GulfPBR Min 26 Ga. GuIfPBR Roof Panel over 1x4 Wood Purlins-over 15/32"-Plywood Limits of Use Approved for use In HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design -Pressure: +N/A/-151.7PSF Other: -100.5 psf @ 24" O.C. fastener spacing.-151.75 psf @ Installation Instructions ELIIC5l. R3 It ri l l65l it,ks mt+r'i K^�^ P'—i 5'9EW Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes Evaluation Reports _ 12" fastener spacing. Install per manufacturer's details. For c:' %' - ` i use in HVHZ Zones n2Plvw .,df Created by Independent Third Party: Yes 11651.19 26 Ga. GuIfPBR Min 26 Ga. GuIfPBR over 15/32" Plywood r Limits of use Approved for use in HVHZ: Yes 1'1t Approved for use outside HVHZ: Yes t Impact Resistant: N/A 11 Design Pressure: +N/A/-154.7PSF Other: -60.5 psf @ 24" o.c. fastener spacing.-154.75 psf @ 412" o.c. fastener spacing. Install per manufacturer's details. Installation Instructions Verified By: Dan Kuhn, P.E. 75519 Created by Independent Third Party: Yes 'Evaluation Reports i-: For use in HVHZ Zones. Created by Independent Third Party: Yes 11651.20 1 26 Ga- GuIfPBR Min 26 Ga. GuIfPBR over 1x4 Wood Purlins over 15/32" Plywood Limits of Use Installation Instructions Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-151.7PSF Other: -94.25 psf @ 24" o.c. fastener spacing.-151.75.psf @ Verified By: Dan Kuhn, P.E. 75519 Created: by Independent Third Party: Yes Evaluation Reports 12" fastener spacing. Install per manufacturer's details. Not for use In HVHZ Zones i Created by Independent Third Party: Yes Go to Page Ci zi 0 Page l/20 0 Comae Us:: 2601a rStoneRoatl 3Pa4assee FL 32399 Phone: 850-487-1824 The State of Florida is an AAIE employec r pvdoht 2OW-701A State of Florida.:: Privacy segment :: Acm ibili�etatement :: Refund Statement Under Florida taw, email addresses are public records. if you do not want your e-mail address released In response to a public-mwrds request, do not send electronic mallto this entity. Instead, cumact the office by phone or by traditional mail. If you have any questions, please canraG 850.487.1395.'Pursuant to SecdOn 455.275(1), Florida Starves, effective October 1, 2012, licensees licensed under ehephur 455, F.S. must provide the Department with an email address If they have https:ltw w.floridabuilding.orglprlpr-app_dtl.aspx?param=wGEVXQMDgsQFcSK%2fTrZeCSHgw99R5wgrf9OEegvkzBZ4cWkSTfwnA"d%3d Page 5 of 6 Florida. Building Code Online 4111119, 10:17 AM one. The ema0s provided may W used far official tommuniralion with the licensee. However email addresses are public record. N you do not Wish W supply a personal address, please provide the Department wdh as email address F.S., please rynuade ilable W the pubbc To datemdne If you are a licensee under Gaptar Product APProval Accepts: EJ � ictaY El Credit Card Safe https://www.floridabuilding.org/pr/pr_app_dtiasPx'param=wGEVXQwtDgsQFc5K%2fTrZeCSHgw99RSwgrfgOEegvkzBZ4cWkSTfwnA%3d%3d Page 6 of 6