Loading...
HomeMy WebLinkAboutPOOL PAPERWORKUNIT DESCRIPTION CONTROLS_ WITH LED READ OUT _L L_JCte County, ELECTRICAL / INSTALLATION PORTS WATER OUT 2" THREADED UNION (INCLUDED) AIR DISCHARGE FAN WARNING: ROTATING BLADE KEEP HANDS & HAIR CLEAR PLATE SCANNED BY St. Lucie County WATER IN 2" THREADED UNION (INCLUDED) PLUMBING & WATER CONNECTIONS 1.BASICPLUMBING. Fora pool only or spa only, install the plumb- ing piping as shown. Connec- PUMP C tions from factory are 2"unions. s• To r Hand tighten then 1/4 to 1/2 snug TO or R tight with pliers. Water IN on the Pool RIGHT, Water OUT on the LEFT. PLUMB AFTER the FILTER & CHLORINATOR PUMPS OVER 70 GPM BEFORE any CHLORINATORS REQUIRE BYPASS HERE or CHEMICAL FEEDERS 2. BYPASS FOR FLOW RATES OVER 70 G.P.M. O Typically the automatic internal water bypass can handle up to a 1.5 H.P. water pump or 70 GP.M. If the water pump exceeds 1.5 H.P. then install either of the optional bypasses as shown below. The installation of a flow meter on the WATER OUT line is suggested. Adjust wr IF through the heater. Flow meters the manufacturer's instructions. C;ITOP VIEW Ir-i a (R VALVE y J 11� h METER Fulet T OF PIPE To POOL be installed per METER WATER I FROM G PUMP POOL FLOW METER TO FROM POOL FR.TFRTO POOL FROM FILTER 3. MULTI UNIT WATER CONNECTIONS Plumb multiple units as shown below. Use flow me- ters on each WATER OUT line if two or more units are plumbed together. Use ball valves to balance the water flow through each unit. Using T's, caps and a minimum 6 inch pipe extension on the plumbing mani- fold will help equalize the water flow better than 90"s. Flow meters should be installed per the manufacturer's instructions. 8 JI I I NOTES UNLESS OTHERWISE SPECIFIED: 1. TO BE USED ON THE FOLLOWING UNITS: AT050, AT075, AT100, AT140, OS115, OS140 O LT0400, LT055, LT0600, LT0700, LT0800, LT1000 ET055, ET075, ET095, ET110, ET135 �E REVISION TABLE REV. PCA NUMBER/DESCRIPTION CHANGED BY DATE DEV-A INITIAL RELEASE RENEEC 11/2812012 DEV-8 ADDED THE 500 CAP UNIT; THE 1400 UNIT WAS A 1300 RENEEC 2/8/2013 REL-C RMV•DREFERENCES TOCUSTOMER RENEEC 10/22/12013 REL-D ADDED MTM NUMBERS TO NOTE 1 & RE -ARRANGED DRAWING VIEW FOR P.E. MARK STEVEF 1/27/2016 I REL-E ADDED TO NOTE 1 - OS MODELS & ET MODELS STEVEF 11/28/2017 2X 114 x 1-1 /2" CONCRETE SCREWS HURRIC/ BRAC MTMC # 10 x 5/8" PAN HEAD, PHIL SST SCREW 3/16" PILI ?.00" DP 10 IN IE. V,VIII L.V LV�?.. BRACKETS TO BE USED PER UNIT %an7 A. ,rj�n nn?r fnndeHnmi'q Fqu,p/nn'/ AUTOPILOTS SYSTEMS - 273724th St. ND. zi --'— St. Petersburg. FL 33713 SALT Cn,. GENERATORS _:=NE V UNLESS OIHERWRE SPECFED. DESCR N rc DRAENSpNS ARE �� """""`"uER5' DIAGRAM,BKT,HURRICANE,MTM072 < TOLERANCES: <�q DECPMLS ANGLES D tOg 78D TBD ,AoceLFDBr R8C puwry ar: RBC wF rRona ENc: JT c"rnrt JT DATE: B/9(2012 DATE'. 11128/2012 UCf OZ PwYEREL trIrORMAIpNCOe,IAWEDMIMR - ORAWNGRINE SOLE PROPFIFIT OE LTMO3O8 V O AOUACAL AUTMOT. V C. AM H KME NW!'SUI NY6gN � REPPOWC1pNN rARI DR WMOIF ��^�� - wRNOIrt wRR1FN PFRmRSpH OF AOUACAE ANOFROi.RK.R VRONWfFO DO NOI SCAT DRAWING CAD FaE'PCP0251 sent I Of I Lml ReviYon. T r akn 1, "T E V cTn Y Aquatherm / Calorex Pool Heat Pumps designed and built the first swimming pool heat pump as an economical way to heat a pool. Over the years we have relentlessly pursued improving our products. Our latest models are the finest'units we have ever offered. In 2018, Aquatherm introduced the 15th generation Whisper Heat AT150. Incorporating the �hermolink tube in shell heat exchanger and a double row evaporator coil, it is our most efficient and highest heat output unit we've ever produced. Our new cabinet design gives our line a fresh new look, while offering one of the quietest pool heat pumps ever produced. HOW A HEAT PUMP WORKS The Aquatherm heat pump utilizes proven refrigerant technology to capture the heat in the outside air and transfer it to the pool water. The fan circulates air across COMPRESSOR cis the evaporator coil and the liquid refrigerant absorb/ heat from the ambient air, transforming it into a gas. Q&Air M The gas is then pumped into the compressor, superheat- ing it. The intensely hot gas is then pumped into the heat exchanger where the heat transfer takes place. As the pool water passes through the heat exchanger, the hot FAt411-1 gas gives up its heat to the cooler pool water. AIR COIL The refrigerant returns to a liquid state and the process EVAPORATOR starts all over again. The result. a warm pool) i C� Pool WI Pump HEAT EXCHANGER ❑ Absorbed Heat From Air CONDENSER Compressed'Hor to Pool Ater Heat is Give to Pool VALVE MODEL NUMBER AT75 AT115 AT130 AT150 BTUs (Water Temp/Ambient Air/Relative Humidity) 80/80/80................................... 72, 000................................110, 000..............................128, 000.............................138, 000 80/80/63................................... 67, 000................................106, 000.............................123, 000 ............................. 129,000 80/50/63................................... 46, 000................................75, 000 ............................... 82,000 ............................... 88,000 Coefficient of Performance (Water Temp/Ambient Air/Relative Humidity) 80/80/80................................... 5.4......................................5.8 .....................................5.7 ..................................... 6.2 80/80/63................................... 5.3......................................5.6 .....................................5.4 ..................................... 5.8 80/50/63................................... 4.0......................................4.0 .....................................4.0 ..................................... 4.0 Refrigerant ..................................... R410A.......... ...................... R410A................................ R410A................................ R410A Compressor ................................... Scroll .................................. Scroll .................................Scroll ................................. Scroll Heat Exchanger ............................. Rifled Titanium ................... Thermolink....................... ..Thermolink......................... Thermolink ................................................. Tube in Tube ...................... Tube in Shell ...................... Tube in Shell ........ - ....... .... Tube in Shell Electrical KWInput..................................3.8......................................4.9.....................................5.8.....................................6.4 Voltage/Hz/Phase..................... 208-230/60/1..................... 208-230/60/ 1.....................208-230/60/1 ..................... 208-230/60/ 1 Min Circuit Ampacity................. 31.65..................................40.2 ...................................41.8 ................................... 41.8 MaxFuse Size ......................... 50.......................................60 ......................................60 ......................................60 Water Flow Min/Max GPM .......................... 30/70.................................. 30/70.................................30/70 ................................. 30/70 Dimensions Weight...................................... 255.....................................295 .................................... 310.................................... 327 L xW xH................................31 x31 x35........ ............... 35x36x37....................... 35x36x41 ....................... 35x36x41 51, www.aquathermheatpumps.com :AQUATHERM 2213 Andrea Lane • Fort Myers, FL 33912.1-800-749-9774 �Ww (feat = _Z FEATU R ES AQUATH ER1) SWIMMING POOL & HEAT PUMPS ..00_ D DIGITAL CONTROLS 2019 • Touch screen controls Permitting Ith temperature lock -out feature - — II electronics encapsulated in epoxy, which isolates components and connections from moisture intrusion, the cause of 98% of control failures DIGITAL MICROPROCESSOR • Seamlessly interfaces with all pool/spa automation systems • Smart defrost control works down to mid to low 40' F THERMOLINK ° TITANIUM HEAT EXCHANGER • Patented tube in shell heat exchanger is more efficient and more durable than less expensive tube in tube heat exchangers. • Patented hydraulic design adds only 1 PSI at 30 gpm, increasing compatibility T' -�' with variable speed pumps. • Titanium tube heat exchanger is the ultimate protection against corrosion from pool chemical imbalance. SOUND INSULATED iCROLL COMPRESSOR -High efficiency -One moving part -Reduced noise level ULTRAVIOLET LIGHT PROTECTED I IL " ABS PLASTIC CABINET Will not rust, crack or corrode Si Y'Il • Molded fan cowling maximizes air flow x, across evaporator coil, increasing efficiency and reducing noise WARRANTY 15 YEARS ON TITANIUM HEAT EXCHANGER AGAINST CORROSION FULL 7 YEARS ON ALL PARTS FULL 2YEARS ON LABOR For units installed in Florida MADE4N F.