Loading...
HomeMy WebLinkAboutEVALUATION REPORT ROOFINGPIOL(� Yk RECEIVED Ft QPRY APR 2018 1}°� permitting Department AT R OF St, Lucte Counev METAL SALES MANUFACTURING CORPORATION '26 GA. IMAGE H PANEL' SCANNED BY St. Lucie County FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 11560.5-R3 ROOFING METAL ROOFING Prepared For: - Metal Sales Manufacturing Corporation 545 South 31 Street, Suite 200 Louisville, KY 40202 Telephone: (502) 8554300 Fax: (502) 855-4200 Prepared By: Bala Sockaling=4 Ph.D., P.E. Florida Professional Engineer #62240 1216 N Lansing Ave., Suite Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation ad SpanTahle (1 Page)) �``,,Q\'P'SOElVgC/NG��i� S' Report No. C2181-5 Date: 9.8.2017 No 62240 ' STATE OF ,•� ��i�s•:ORIOP.N,,� 9.4.20li FL 11560.5-R3 C2181-5 9.8.2017 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image II Panel Description: Max. 16" wide coverage with 1" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 19/32" plywood or min. %" thick wood plank (min SG of 0.42) for new and existing constructions. Designed and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c. (Minimum) in the field and edges. Designed as per FBC 2017. Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1 Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) 102.7 psf @ fastener spacing of 6" o.c. 139.1 psf @ fastener spacing of 6" o.c. with 3/8" bead adhesive in panel sidelap Fastener Pattern: At panel seam #10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of/4". Sidelap Adhesive: Schnee -Morehead SM7108 Permathane adhesive Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4 Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. The design pressure for reduced fastener spacing may be computed using rational analysis prepared by a Florida Professional Engineer or based on Metal Sales load span table. This evaluation report is not applicable in High Velocity Hurricane Zone. Refer to current NOA for use of this product in High Velocity Hurricane Zone. FL 11560.5-R3 C2181-5 9.8.2017 Page 3 of 3 Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. Supporting Documents: TAS 125 Test Reports Farabaugh Engineering and Testing Inc. Project No. T241-07, Reporting Date 7/23/07 Hurricane Test Laboratory, LLC HTL Report #: 0103-0714-09, Reporting Date 9/1/09 ROOF PANESEE DETAIL 1 L F� MAX. ifi'PANEL FASTENER I SPACING PER ALLOWABLE o PRESSURE TABLE. n `- / II PLYWOOD II UNDERLAYMENT SHALL BE INSTALLED AS PER INSTALLATION 8d x 2.5" LONG RING SHANK NAIL 19/32' THICK OR #8 z 2° LONG WOOD SCREWS (MIN.) GUIDELINESMANUFACTURER'S MIN. 2X_ WOOD RAFTER/JOIST/ SPACED 0 6" O.C. IN THE FIELD & TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES FASTENING PATTERN 1 SEE DETAIL 2 ADHESIVE IN THE ROOF PANEL --� PANEL SIDEIAP / MAX, 16" PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. n SHALL 'S INSTALLED AS PER AS PER MANUFACTURER'S INSTALLATION n PLYWOOD 8d x 2.5' LONG RING SHANK NAIL 19/32° THICK (MIN.) „e ee „ ,,, ,,,,,,, ,,,,,,,,, �„e�„� II II I GUIULUNLS SPACED "0 6' O.C. IN THE FIELD & MIN. 2X- WOOD RAFTER/JOIST/ TRUSS AT MAX. 24" O.C. AT PLYWOOD EDGES FASTENING PATTERN 2 TYPICAL PANEL INSTALLATION X-SECTION MIN 26 GA. PANEL PCAKESCREWSNG AN DETAIL 1 AT MAX. 6" G.C. UNDERLAYMENT PLYWOOD 19/32" THICK (MIN.) SIDELAP ADHESIVE SIDE 3/8° BEAD MIN 26 GA. PANEL—\,j NOM. #10-12 X 1" LONG PANCAKE SCREWS AT MAX 6" 0 C DETAIL 2 UNDERLAYMENT PLYWOOD 19/32" THICK (MIN.) GENERAL NOTES: 1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE FLORIDA BUILDING CODE BC). 2. ROOF PANEIS SHPL. BE IN. 26 GA. (t - 0.01677. MAX. EFFECRVE COVERING WIDTH OF PANEL - 16'. 3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS SPECIFIED ON THIS DRAWING. 4. REQUIRED DESIGN WINO LOADS SHALL BE DETERMINED MR EACH PROJECT. THI 61 6. a rc U O a ,rj N 2 OF METAL SAi.F,S MANUFACTURING CORPORATION Image II Uplift Loads (Min. 26 ga.) Description Fastener Spacing along Panel Length (in) Allowable Uplift Load (psf) Coverage width: 16" Panel Fastener: #10-12 pancake head screws 6 102.7 8 100.7 10 98.6 12 96.6 14 94.5 16 92.5 18 90.4 20 88.4 22 86.3 24 84.3 With Sidelap Sealant 6 139.1 Notes: 1. The bold numbers indicate design loads calculated from test data with safety factor of 2. 2. Panels must be installed as per Evaluation Report FL 11560.5 and Metal Sales current installation procedure. 3. Three or more spans condition. 1216 N Lansing Ave., Suite C Tulsa, Ok 74106 918 492 5992 `tttt1ti1111j1j ���I(q P SOC O`,���ii No 62240 •.•� C) STATE OF mac: ,:I-. ?_0 k 1 Bala Sockalingam, Ph.D., P.E. FL 62240