Standby Generators
Perm 1I'ing 9eparttMVant Liquid -Cooled Gaseous Engine
st, Luefo County
INCLUDES: BY Standby Power Rating
• Two -Line LCD Multilingual Digital St. Lucie COUPAydel RGO22 (Aluminum - Bisque) - 22 kW 60 Hz
Evolution'" Controller (English/Spanish/ Model RG027 (Aluminum - Bisque) - 27 kW 60 Hz
French/Portuguese) with external viewing Model RG032 (Aluminum - Bisque) - 32 kW 60 Hz
window for easy indication of generator Model RG038 (Aluminum - Bisque) - 38 kW 60 Hz
status and breaker position. Model RG048 (Aluminum - Bisque) - 48 kW 60 Hz
• True Power'" Electrical Technology
• Isochronous Electronic Governor STLUCIECOUNTY
• Sound Attenuated Enclosure PLAN REVIEW
• Closed Coolant Recovery System
BLDG
• Smart Battery Charger DATE
• UV/Ozone Resistant Hoses E4,
• -t 1 % Voltage Regulation DATE-/ f-!�
• Natural Gas or LP Operation PLUMB:
DATE:
• 5 Year Limited Warranty
MECH:
• UL 2200 Listed DATE:
• Capability to be installed within 18"
(457) mm of a building*
GE�Eq=C
Emm
Eta QUID
Meets EPA Emission Regulations
'Only if located away from doors, windows, and fresh air 22 & 27 kW are CA/MA emissions compliant
intakes, and unless otherwise directed by local codes. 32 & 38 kW not for sale in CA / MA
FEATURES
O INNOVATIVE DESIGN & PROTOTYPE TESTING are key components of
GENERAL'S success in "IMPROVING POWER BY DESIGN." But it
doesn't stop there. Total commitment to component testing, reliability
testing, environmental testing, destruction and life testing, plus testing
to applicable CSA, NEMA, EGSA, and other standards, allows you to
choose GENERAC POWER SYSTEMS with the confidence that these
systems will provide superior performance.
O SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION.
This slate i-the-arl power maximizing regulation system is standard on
all Generac models. It provides optimized FAST RESPONSE to changing
load conditions and MAXIMUM MOTOR STARTING CAPABILITY by
electronically torque -matching the surge loads to the engine. Digital
voltage regulation at ±1 %.
O SINGLE SOURCE SERVICE RESPONSE from Generac's extensive dealer
network provides parts and service know-how for the entire unit, from the
engine to the smallest electronic component.
o TEST CRITERIA: O GENERAC TRANSFER SWITCHES. Long life and reliability are
• PROTOTYPE TESTED v NEMA MG1-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this
• SYSTEM TORSIONAL TESTED v MOTOR STARTING ABILITY confidence is that the GENERAC product line Includes its own transfer
systems and controls for total system compatibility.
IVA
ii 1zo°G'e' i
GENERAL'
22.27.32.38.48kW
GENERATOR SPECIFICATIONS
Type
Synchronous
Rotor Insulation Class
H (22 & 27 kW) or
F (32, 38 & 48 kW)
Stator Insulation Class
H
Telephone Interference Factor (TIF)
<50
Alternator Output Leads 1-Phase
4 wire
Alternator Output Leads 3-Phase
6 wire
Bearings
Sealed Ball
Coupling
Flexible Disc
Excitation System
Direct
VOLTAGE REGULATION
Type
Electronic
Sensing
Single Phase
Regulation
. 1%
GOVERNOR SPECIFICATIONS
Type
Electronic
Frequency Regulation
Isochronous
Steady State Regulation
t 0.25%
ELECTRICAL SYSTEM
Battery Charge Alternator
12 Volt 30 Amp
Static Battery Charger
2.5 Amp
Recommended Battery (battery not included)
Group 26 (22, 27, 32 & 38 km
or Group 24F (48 kW), 525CCA
System Voltage
12 Volts
GENERATOR FEATURES
Revolving field heavy duty generator
Directly connected to the engine
Operating temperature rise 120 °C above a 40 °C ambient
Class H insulation is NEMA rated
Class F insulation is NEMA rated
All models fully prototyped tested
ENCLOSURE FEATURES
Aluminum weather
Ensures protection against mother nature.
protective enclosure
Electrostatically applied textured epoxy paint for added
durability.
Enclosed critical grade
Quiet, critical grade muffler Is mounted inside the unit
muffler
to prevent injuries.
Small, compact, attractive
Makes for an easy, eye appealing installation.
SAE
Sound attenuated enclosure ensures quiet operation.
(All ratings in accordance with BS5514, ISO3046, ISO8528, SAE J1349 and DIN6271)
ENGINE
application & engineering data
22. 27. 32 & 38 kW
Make
Generac
Model
In -line
Cylinders
4
Displacement (Liters)
2.4
Bare (iNmm)
3.41/86.5
Stroke (iNmm)
3.94/100
Compression Ratio
9.5:1
Intake Air System
Naturally Aspirated (22 & 27"or
Turbocharged/After000led
(32 & 38 kW)
Lffter Type
Hydraulic
ENGINE SPECIFICATIONS: 48 kW
Make
Generac
Model
VType
Cylinders
8
Displacement (Liters)
5.4
Bore (Irt/mm)
3.55/90.2
Stroke (iNmm)
4.17/105.9
Compression Ratio
9:1
Intake Air System
NaturallyAsplated
Litter Type
Hydraulic
ENGINE LUBRICATION SYSTEM
Oil Pump Type Gear
Oil Filler Type Full flow spin -on cartridge
Crankcase Capacity (qVp 4/3.8 (22, 27, 32 & 38 kW) or
6/5.7 (48 kW)
ENGINE COOLING SYSTEM
Type
Closed
Water Pump
Belt driven
1980 - 22 & 27 kW
Fan Speed (rpm)
1500 - 32 & 38 kW
1954 - 48 kW
16.11459.7 (22 & 27 kW) or
Fan Diameter (iNmm)
22/558.8 (32, 38 & 48 kW)
Pusher (22 & 27 kW) or
Fan Made
Puller (32. 38 & 48 kW)
FUEL SYSTEM
Fuel Type
Natural gas, propane vapor
Carburetor
Down Draft
Secondary Fuel Regulator
Standard
Fuel Shut Off Solenoid
Standard
Operating Fuel Pressure
5-14° water column/9-26 mm HG
LP Fuel Pressure
11 -141 Water Column
NG Fuel Pressure
5 -141 Water Column
22.27.32.38.48kW
GENERAC°
operating data
GENERATOR OUTPUT VOLTAGE/kW - 60 Hz
kW LPG Arno LPG kW Nat. Gas Amu Nat. Gas CB Size (Both)
120/240 V, 10, 1.0 pf
22
92
22
92
100
RG022
120/208 V, 30. 0.8 pf
22
76
22
76
80
120/240 V, 30, 0.8 pf
22
66
22
66
80
120/240 V. 10, 1.0 pf
27
113
25
104
125
RG027
120/208 V, 30, 0.8 of
27
94
25
87
100
120/240 V. 30. 0.8 pi
27
81
25
75
90
120/240 V. 10. 1.0 pf
32
133
32
133
150
120/208 V, 30, 0.8 pf
32
111
32
111
125
RG032
120/240 V, 30, 0.8 pf
32
96
32
96
100
277/480 V, 30, 0.8 pf
32
48
32
48
60
120/240 V. 10, 1.0 pf
38
15B
38
158
175
120/208 V, 30. 0.8 pf
38
132
38
132
150
R6038
120/240 V, 30, 0.8 of
38
114
38
114
125
2771480 V. 30. 0.8 pf
38
57
38
57
60
1201240 V. 10. 1.0 pf
48
200
48
200
200
1211208 V, 30, 0.8 pf
48
167
48
167
175
RG048
120/240 V, 30, 0.8 pl
48
144
48
144
150
277/480 V, 30, 0.8 pf
48
72
48
72
80
SURGE CAPACITY IN AMPS ENGINE FUEL CONSUMPTION
Voltage Dip @ <.4 pf Natural Gas Propane
15% 30% (D3/hr) 03/hr) (gaVhr) (Vhr) (113/hr)
120/240 V, 10
55
135
8G022
120/208 V, 30
40
92
120/240 V. 30
35
80
120/240 V, 10
62
170
RG027
120/208 V, 30
70
120
120/240 V, 30
61
103
120/240 V, 10
75
180
120/208 V, 30
87
210
RG032
120/240 V, 30
75
182
277/480 V, 30
36
87
120/240 V. 10
75
180
1201208 V, 30
87
210
RG038
120/240 V. 30
75
182
277/480 V. 30
36
87
120/240 V. 10
85
195
120/208 V, 30
90
218
RG048
120/240 V, 30
78
189
277/480 V, 30
36
87
Note: Fuel pipe must be sized for full load.
For Btu content, multiply ft3/hr x 2520 (LP) or 83/hr x 1000 (NG)
For megajoule content, multiply m3/hrx 93.15 (LP) or m3/hrx 37.26 INS)
Refer to "Emissions Data Sheets° for maximum fuel flow for EPA and
SCAOMD permitting purposes.
Exercise cycle
42
1.2
0.44
1.7
16
25% of rated load
100
2.8
1.1
4.2
40
RG022
50% of rated load
190
5.4
2.1
7.8
75
75% of rated load
255
7.2
2.8
10.5
101
100%of rated load
316
9
3.4
13
125
Exercise cycle
42
1.2
0.44
1.7
16
25% of rated load
108
3.1
1.2
4.5
43
RG027
50% of rated load
197
5.6
2.1
8.1
78
75% of rated load
287
8.2
3.1
11.8
114
100%of rated load
359
10.2
3.9
14.8
143
Exercise cycle
79
2.2
0.8
3.2
30
25% of rated load
144
4.1
1.7
6.3
60
RG032
50% of rated load
226
6.4
2.7
10.3
97
75% of rated load
298
6.4
3.7
13.9
132
100% of rated load
375
10.6
4.6
17.5
166
Exercise cycle
83
2.3
0.9
3.2
31
25% of rated load
162
4.6
1.7
6.6
62
RG038
50% of rated load
255
7.2
2.9
10.8
103
75% of rated load
345
9.8
4 1
15 1
142
log% of rated load
437
12.4
5.2
19
185
Exercise cycle
95
2.7
1
3.9
38
25% of rated load
204
5.8
2.16
8.5
82
RG048
50% of rated load
392
11.1
4.14
15.7
151
75% of rated load
547
15.5
5.8
22.8
220
100%of rated load
756
21.5
7.96
31.3
302
STANDBY RATING: Standby ratings apply to installations served by a reliable utility source. The standby rating is applicable to varying loads for the duration of a power outage. There
is no overload capability for this rating. Ratings are in accordance with ISO-3046-1. Design and specifica0ons are subject to change without notice.
GENERAC°
IIIIIIIIIIIIIIN
22 • 27 • 32 • 38 • 48 IcW operating data
ENGINE COOLING
22 kW 27 kW 32 & 38 kW 48 kW
Air flow (Inlet air including alternator and combustion air in cfm/cmm)
2400/68
2400/68
1 2200/62.3
4350/123.2
System coolant capacity (gal/liters)
2.5/9.5
2.4.5
2.5/9.5
3/11.4
Heat rejection to coolant (BTU per hr/MJ per hr)
99.000/104.5
105,000/110.8
145,000/153
186,000/196.2
Maximum operation air temperature an radiator (°C/'F)
60/150
Maximum ambient temperature (*CM
50/140
COMBUSTION REQUIREMENTS
Flaw at rated power(cfm/cmm) 68/1.9 68/1.9 106/3 163/4.6
SOUND EMISSIONS
Sound output in dB(A) at 23 it (7 m) with generator in exercise mode'
1 61
61
58
63
Sound output in dB(A) at 23 it V m) with generator operating at normal load'
1 70
70
64
68
'sound levels are taken from the front of the generator. Sound levels taken from other sides of the generator may he higher depending on Installation parameters.
EXHAUST
Exhaust flow at rated output(cfm/cmm)
1 165/4.7
1 180/5.1
30018.5
414/11.7
Exhaust temperature at muffler outlet(°C/°F)
1 482/900
1 538/1000
579/1075
552/1025
ENGINE PARAMETERS
Rated Synchronous rpm 1800
POWER ADJUSTMENT FOR AMBIENT CONDITIONS
Temperature Deration...........................................................................................................3%for every 10 °C above 25 °C or 1.65% for every 10 °F above 77 °F
Altitude Deration (22, 27 & 48 kW).....................................................................................1% for every 100 m above 183 m or 3%for every 1000 it above 600 it
Altitude Deration (32 & 38 kW) ............................... ........................................................ 1%for every 100 m above 915 m or 3°% for every 1000 it above 3000 it
CONTROLLER FEATURES
Two -Line Plain Text LCD Display....................................................................................................................................Simple
user interface for ease of operation.
Mode Switch: Auto..............................................................................................................................................Automatic
Start on Utility failure. 7 day exerciser
Off...........................................................................................................................Stops
unit. Power Is removed. Control and charger still operate.
Manual.........................................................................................
Start with starter control, unit stays on. If utility fails, transfer to load takes place.
Programmable start delay between 10-30 seconds.................................................................................................................................................10
sec standard
Engine Start Sequence.....................................................................................................................
Cyclic cranking:16 sec on, 7 rest (90 sec maximum duration)
EngineWarm-up.....................................................................................................................................................................................................................5
sec
EngineCool-Down..................................................................................................................................................................................................................1
min
Starter Lock-out................................................................................................................................Starter
Gannet re-engage until 5 sec after engine has stopped.
SmartBattery Charger........................................................................................................................................................................................................
Standard
Automatic Voltage Regulation with Over and Under Voltage Protection................................................................................................................................
Standard
Automatic Low Oil Pressure Shutdown...............................................................................................................................................................................
Standard
OverspeedShutdown..............................................................................................................................................................................................Standard,
72 Hz
HighTemperature Shutdown...............................................................................................................................................................................................Standard
OvercrankProtection..........................................................................................................................................................................................................Standard
SafetyFused......................................................................................................................................................................................................................Standard
Failureto Transfer Protection..............................................................................................................................................................................................
Standard
LowBattery Protection........................................................................................................................................................................................................
Standard
50 Event Run Log...............................................................................................................................................................................................................Standard
FutureSet Capable Exerciser..............................................................................................................................................................................................Standard
IncorrectWiring Protection.................................................................................................................................................................................................
Standard
InternalFault Protection.....................................................................................................................................................................................................Standard
CommonExternal Fault Capability ......................................................................................................................................................................................Standard
GovernorFailure Protection................................................................................................................................................................................................Standard
22 . 27 . 32 . 38 . 48 kW
GENERAC
available accessories
Model # Product Description
Generac's Mobile Link allows you to check the status of your generator from
anywhere that you have access to an Internet connection from a PC or with
G006463-4
Mobile Link'
any smart device. You will even be notified when a change in the generator's
status occurs via e-mail or text message. Note: Harness Adapter Kit required.
Available in the U.S. only.
G006478-0
Harness Adapter Kit
The Harness Adapter Kit is required to make liquid -cooled units compatible
with Mobile Link"'.
G005630-1 - 22, 27, 32 & 38 kW
If the temperature regularly falls below 32 OF (0 °C), install a cold weather kit
Cold Weather Kit
to maintain optimal battery temperature. Kit consists of battery warmer with
G005632-1- 48 kW
thermostat built into the wrap.
G005616-0 - 22, 27, 32 & 38 kW
Extreme Cold
Recommended where the temperature regularly falls below 32 OF (0 °C) for
G007088-0 - 48 kW
Weather Kit
extended periods of time. For liquid cooled units only.
I
G005651-0
Base Plug Kit
Add base plugs to the base of the generatorto keep out debits.
If the generator enclosure is scratched or damaged, it is important to
G005703-0 - Bisque
Paint Kit
touch-up the paint to protect from future corrosion. The paint kit includes the
necessary paint to properly maintain or touch-up a generator enclosure.
G005656-0 - 22 & 27 kW
Scheduled
The Liquid -Cooled Scheduled Maintenance Kits offer all the hardware
G005984-0 - 32 & 38 kW
Maintenance Kit
necessary to perform complete maintenance on Generac liquid -cooled
G006205-0 - 48 kW
generators.
G006664-0
Local Wireless
Completely wireless and battery powered, Generac's wireless remote monitor
Monitor I
provides you with instant status information without ever leaving the house.
G006665-0
Wireless Remote
Recommended for use with the Wireless Remote on units up to 60 kW,
Extension Harness
required for use on units 70 kW or greater.
Smart Management Modules are used in conjunction with the Automatic
G006873-0
Smart Management
Transfer Switch to increase its power management capabilities. It provides
Module (50 Amps)
additional power management flexibility not found in any other power
management system.
G006510-0
E-Stop
E-stop allows for immediate fuel shutoff and generator shutdown in the event
of an emergency.
The Wi-Fi enabled LP fuel level monitor provides constant monitoring of the
Wi-Fi LP Fuel Level
connected LP fuel tank. Monitoring the LP tank's fuel level is an important
G007005-0
Monitor
step in making sure your generator is ready to run during an unexpected
power failure. Status alerts are available through a free application to notify
when your LP tank is in need of a refill.
RADIATORIEXHAUST
OISCHARGEAIR
(BOTH SIDES)
167
[6.6]
13—
"-
121.11
ZY O.D.
RADIATO
DISCHARGEAIR
314"
AIR INTAKE
(BOTH SIDES
768 302]
CENTER OF GIV
SEE NOTE 6
=CONNECRON / 1 D [2.0]
ECOUPUNG 1000 [39.4[
LEELSIDE\aw
OMENSIONS
26
REFERENCE OWNERS MMMAI
FOR PERIODIC REPLACEMENT
PAR UUFNGS.
—REARENCLOSURE
ASSEMBLY, CONTROL
PANELACCESS,BATTERY
0SEENOPMELTE4USTOMERACCESS
CHARGER
LOCATEDWITHIN
SEENOTE4
888 [35.01
47
V.]
ERALL WIDTH
[7.8]�..
1950 [76.8]—
REM1VIEW
TYP
OVERALL LENGT
RIGHT SIDE VIEW
W GMMTR
QIGINEMW
GENBETOM.Y SpPRNpSND
°WVPWG WEIGM
BN�EWGME
KGPBSI Na asry
NO B°N
3AL ]3I(W
µ
559 fzz U BB
w HB]31
2Q BBHW
qL
iE UBGSj aIa
IN 333
DIMENSIONS: MM VNCH]
MCEACTIONLATCH,
ONE PER DOOR
ONE LIFT OFF
DOOR PER SIDE
OF GENERATOR
58
[2.3]
TYP
0
W
N
Q�
w
co
pr
4
Ca!
N
20
Cal
CC)
Cr
G
50 7VP
[2.0]