HomeMy WebLinkAboutNOAMIMI M
•
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATIONDIVISION SCANNED
NOTICE OF ACCEPTANCE (NOA) C♦• � I loin ('nnr
Inc.
10303 General Dr.
Orlando, FL 32824
MIAMI-DADS COUNTY
PRODUCT CONTROL SECTION
11805 SW 26 Stre Room 208
Miami, Florida 33175-2474
T (786) 315-2590 F (786) 315-2599
ww .miamidade.eov/buildine
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials.
The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control
Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction
(AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control
Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to
have this product or material tested for quality assurance purposes. If this product or material fails to perform in
the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately
revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right
to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or
material fails to meet the requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane
Zone of the Florida Building Code.
DESCRIPTION: MD-CMA Skylight.
APPROVAL DOCUMENT: Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2, prepared by
Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October
06, 2017, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance
number and the expiration date by the Miami -Dade County Product Control Section.
MISSILE IMPACT RATING: Large and Small Missile Impact Resistant
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and
following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless
otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no
change in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in
the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any
product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply
with any section of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by
the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it
shall be done in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors
and shall be available for inspection at the job site at the request of the Building Official.
This NOA revises NOA #15-0513.05 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as
well as approval document mentioned above.
The submitted documentation was reviewed by H/ ehmy A. Makar, P.E., M.S.
NOA No. 17-1023.18
MIAMMADE COUNTY 1.
� QQQ"' Expiration Date: 03/13/20233/2023
Approval Date: 03/15/2018
Page 1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06
A. DRAWINGS
1. Manufacturer's die drawings and sections.
2. Drawing No. CMA-002, titled "MD -CM ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by
Rene Quiroga, P.E.
B. TESTS
L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94
along with marked -up drawings and installation diagram of Model JIDD-CMA Curb
Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories,
Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E.
C. CALCULATIONS
1. Anchor calculations prepared by Product Technology Corporation on 02105103,
signed and sealed by A. Perez Maldonado, PE.
D. QUALITY ASSURANCE
1. Miami Dade Building Code Compliance Office (BCCO)
E. MATERIAL CERTIFICATIONS
1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their
"Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08.
F. STATEMENT
1. Code compliance letter issued by Product Technology Corporation on 02/06/03,
signed and sealed by A. Perez Maldonado
(Evidence Submitted under NOA # 03-0401.07)
G. OTHERS
1. Notice of Acceptance No. 03-0401.07, issued to Sun-Tek Manufacturing, Inc.,
approved on 10/09/03 and expiring on 03/13/08.
2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01/02/08, signed by
James Feudner.
elmy A. Makar, P.E., MR
-
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E-1
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04
A. DRAWINGS
L Drawing No. CMA-002, titled `.LID-CMA ", sheets I and 2 of 2, prepared by Sun-Tek
Manufacturing Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on May 08, 2012.
B. TESTS
L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94
2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94
3) Water Resistance Test, per FBC, TAS 202-94
4) Large Missile Impact Test per FBC, TAS 201-94
5) Cyclic Wind Pressure Loading per FBC, TAS 203-94
6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94
along with marked -up drawings and installation diagram of Model AM -CAM Curb
Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories,
Test Report No. NCTL-210-3859-1, dated 03104113, signed and sealed by Gerard J.
Ferrara, P.E.
C. CALCULATIONS
1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated
0311912013, signed and sealed by James D. Wells, Jr., P.E.
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 0412512OIZ signed and sealed by James D. Wells, Jr., P.E.
3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05
A. DRAWINGS
L Drawing #CM4-002, titled "MIJ-CMA", sheets I and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on
05108112.
B. TESTS
1. None.
C. CALCULATIONS
1. None.
my A. Makar, P.E., M.S.
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E -2
Sun-Tek Manufacturing, Inc.
NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED
D. QUALITY ASSURANCE
1. By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
L None.
F. STATEMENT
1. Florida Building Code, 2014 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E.
4. NEW EVIDENCE SUBMITTED
A. DRAWINGS
1. Drawing No. CAA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek
Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr.,
P.E., on October 06, 2017.
B. TESTS
1. None.
C. CALCULATIONS
L None.
D. QUALITY ASSURANCE
L By Miami -Dade County Department of Regulatory and Economic Resources.
E. MATERIAL CERTIFICATIONS
1. None.
F. STATEMENT
1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells
Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E.
�el�.. Maka�S
Product Control Section Supervisor
NOA No. 17-1023.18
Expiration Date: 03/13/2023
Approval Date: 03/15/2018
E -3
Engineer of Record:
James D. Wells, Jr., P.E.
Professional Engineer No. 53616
-tI t—
M
CO
DIMENSIONS FOR
FASTENER LOCATIONS
14 FASTENERS
TO CURB
6 RIVETS
POLY TO ALUM
RIVET LOCATIONS SYM
J 8E L Wells Consulting LLC
1453 Arbilus Circle
Oviedo, Fl, 32765
(407)496-5489
Certificate of Authorization No. 27162 5
3.0000'(p10.625—I �}F''
I
0
S
ri
0
MD-CMA 2246
0
0
O
M
9R.If SWµ�p[M!y
No. P w . Pkb�y,N
.I.. s.,.x., nx�
iluflo&
Flo s 2 PNLUn Pµ 1FPn Nrzn UOu ssa,
I., eP .P >m.. w °..w.r a1
fI° • p °i0 YHfl
P)PHa PSN
yy53616
Zor ice=
SEOF *7.
at,
DWO.N: CMA-002
1111
wIw ImM[.Pm PCYGP6H1fF
aro Pmruemw.rt srtn
w,aR Pu�w .
Zvi uaM wv
s mwn o
n m ISF os�wPR �¢nn,1w-^P_[
I�y�yK4M R m^�n
M I0.V[ f°TR°°l SlA/QI
w ^[° . IN mnls ,
NOTE: v+P"°' IUM vwwn
• (1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2DI7 FLORIDA BUILDING CODE
(2) A" MINIMUM DISTANCE FROM ANGLE LIP 10 ROOF
SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT
INSULATION. FOR INSULATION AND TILE ROOF ADD LAR
TILE HEIGHT AND INSULATION THICKNESS TO 4-
MINIMUM HEIGHT.
(3) ANCHORS TO BE MADE OF NDN-CORROSNE MATERIAL.
ATABLE WITH ALUMINUM.
w
m�
. .0 a w1RLY M 1
��1 SN
mrvnl
PPODUC-fREVISED
as complylug cvith the Florsd<;
Building (;ode
Acceptance No/ - aZ3. 9
Expitaiicn DR4e O
BY Zy
MD—CMA SUN-TEK MANUFACTURING, INC.
AL I 0 G N4. A- 10303 GENDNAL DRbr ORLANDO. FL 32824
Engineer of Record!
James D. Wells, Jr., P.E.
Professional Engineer No. 53616
J & L Wells Consulting LLC
1453 Arbitus Circle
Oviedo, FL 32765
(407)496-5489
Certificate of Authorization No. 27162
• DESIGN PRESSURE RATING
+- 60
#10 % 2" SCREW PPH PSF
LARGE MISSLE IMPACT RESISTANCE
(4) ON LONG SIDE& (3) ON SHORT SIDE
MINIMUM ENBEDMENT 1"
RIG STI-275
O600 THICK ALUMINUM
AND3WEL WELDED
-JTuv 90' .
MIN
4" MINIMUM
SEE NOTE #2 tz
(2)
TER LINER .030 polyc
(Polrom Palsun,
Sheffield Mokrolon or
Sobic Lemon 9034)
US complying with the?riovida
Building Code
FINISHED WALL MATERIAL
BY OTHERS ( APPROVED
DADE COUNTY)
5-1/2" DOME RISE
ipeN
516
Lo/}
OF
-OUTER DOME .070 POLYCARSONATE
(Polrom Palsun,
Sheffield Makrolon or
Sobic Leman 9034)
AIR FILLED INSULATED SPACE
#10 x 3" DECK SCREW
(4) ON LONG SIDE
(3) ON SHORT SIDE -
MINIMUM ENBEDMENT 5/8"
NOTE:
(1) ALL ROOFING DETAILS SHALL COMPLY WITH
CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE
DWG.11+ CMA-002
_. i SILICONE BEDDING (CONTINUOUS)
(2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF
2X SYP (SG 0.55) CURB HEIGHT
SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT
TO BE SUFFICIENT TO MAINTAIN
INSULATION. FOR INSULATION AND TILE ROOF ADD
4" MINIMUM AT LOWEST POINT
TILE HEIGHT AND INSULATION THICKNESS TO 4"
MINIMUM HEIGHT.
OF FRAME TO ROOF SURFACE
SUPPLIED BY OTHERS AN
(3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL, ROOF DECK
(APPROVED BY DADE COUNTY)
COMPATABLE WITH ALUMINUM.
STS-1000 SEALANT (CONTINOUS)
BUTYL RUBBER SEALANT
BETWEEN SKYLIGHT
AND CURB (continuous)
rSHIM® EA, ANCHOR (TYP)
WITH LOAD BEARING SHIM
�_O.500 MM.
3/16" RIVET
�/LONG SIDE
I /SHORT SIDE
FLASHING BY OTHERS IN
ACCORDANCE WITH NRCA
NAME,
MD-CMA SUN-TEK MANUFACTURING, INC.
A D _ 10303 GENERAL DRNE MAND0. FL 321324
0
\❑