HomeMy WebLinkAboutNOAMIMI M • DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATIONDIVISION SCANNED NOTICE OF ACCEPTANCE (NOA) C♦• � I loin ('nnr Inc. 10303 General Dr. Orlando, FL 32824 MIAMI-DADS COUNTY PRODUCT CONTROL SECTION 11805 SW 26 Stre Room 208 Miami, Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 ww .miamidade.eov/buildine SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: MD-CMA Skylight. APPROVAL DOCUMENT: Drawing No. CMA-002, titled "MD-CMA", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017, bearing the Miami -Dade County Product Control Revision stamp with the Notice of Acceptance number and the expiration date by the Miami -Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved" or the Product Control Seal, unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0513.05 and consists of this page 1, evidence submitted pages E-1, E-2, and E-3 as well as approval document mentioned above. The submitted documentation was reviewed by H/ ehmy A. Makar, P.E., M.S. NOA No. 17-1023.18 MIAMMADE COUNTY 1. � QQQ"' Expiration Date: 03/13/20233/2023 Approval Date: 03/15/2018 Page 1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #08-0110.06 A. DRAWINGS 1. Manufacturer's die drawings and sections. 2. Drawing No. CMA-002, titled "MD -CM ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated 09113195 and 04125195, with no revisions, signed and sealed by Rene Quiroga, P.E. B. TESTS L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model JIDD-CMA Curb Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories, Test Report #210-2885-1, dated 10131102, signed and sealed by W. A. Davis Jr., P.E. C. CALCULATIONS 1. Anchor calculations prepared by Product Technology Corporation on 02105103, signed and sealed by A. Perez Maldonado, PE. D. QUALITY ASSURANCE 1. Miami Dade Building Code Compliance Office (BCCO) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No. 07-0212.01 issued to General Electric Plastics for their "Lexan Sheet Products", approved 05/25/07, expiring on 07/17/08. F. STATEMENT 1. Code compliance letter issued by Product Technology Corporation on 02/06/03, signed and sealed by A. Perez Maldonado (Evidence Submitted under NOA # 03-0401.07) G. OTHERS 1. Notice of Acceptance No. 03-0401.07, issued to Sun-Tek Manufacturing, Inc., approved on 10/09/03 and expiring on 03/13/08. 2. No change letter issued by Sun-Tek Manufacturing, Inc., dated 01/02/08, signed by James Feudner. elmy A. Makar, P.E., MR - Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E-1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #11-0601.04 A. DRAWINGS L Drawing No. CMA-002, titled `.LID-CMA ", sheets I and 2 of 2, prepared by Sun-Tek Manufacturing Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on May 08, 2012. B. TESTS L Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 24113.2.1, TAS 202-94 along with marked -up drawings and installation diagram of Model AM -CAM Curb Mounted Plastic Dome Skylight, prepared by National Certified Testing Laboratories, Test Report No. NCTL-210-3859-1, dated 03104113, signed and sealed by Gerard J. Ferrara, P.E. C. CALCULATIONS 1. Anchor calculations prepared by J & L Wells Consulting LLC, 19 pages, dated 0311912013, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2010 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 0412512OIZ signed and sealed by James D. Wells, Jr., P.E. 3. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL #15-0513.05 A. DRAWINGS L Drawing #CM4-002, titled "MIJ-CMA", sheets I and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated 05109111, signed & sealed by James D. Wells, Jr., P.E., on 05108112. B. TESTS 1. None. C. CALCULATIONS 1. None. my A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E -2 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED D. QUALITY ASSURANCE 1. By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS L None. F. STATEMENT 1. Florida Building Code, 2014 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. 4. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. CAA-002, titled "MD-CMA ", sheets 1 and 2 of 2, prepared by Sun-Tek Manufacturing, Inc., dated May 09, 2011, signed and sealed by James D. Wells, Jr., P.E., on October 06, 2017. B. TESTS 1. None. C. CALCULATIONS L None. D. QUALITY ASSURANCE L By Miami -Dade County Department of Regulatory and Economic Resources. E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENT 1. Florida Building Code, 2017 Edition, compliance letter prepared by J & L Wells Consulting LLC, dated 1010612017, signed and sealed by James D. Wells, Jr., P.E. �el�.. Maka�S Product Control Section Supervisor NOA No. 17-1023.18 Expiration Date: 03/13/2023 Approval Date: 03/15/2018 E -3 Engineer of Record: James D. Wells, Jr., P.E. Professional Engineer No. 53616 -tI t— M CO DIMENSIONS FOR FASTENER LOCATIONS 14 FASTENERS TO CURB 6 RIVETS POLY TO ALUM RIVET LOCATIONS SYM J 8E L Wells Consulting LLC 1453 Arbilus Circle Oviedo, Fl, 32765 (407)496-5489 Certificate of Authorization No. 27162 5 3.0000'(p10.625—I �}F'' I 0 S ri 0 MD-CMA 2246 0 0 O M 9R.If SWµ�p[M!y No. P w . Pkb�y,N .I.. s.,.x., nx� iluflo& Flo s 2 PNLUn Pµ 1FPn Nrzn UOu ssa, I., eP .P >m.. w °..w.r a1 fI° • p °i0 YHfl P)PHa PSN yy53616 Zor ice= SEOF *7. at, DWO.N: CMA-002 1111 wIw ImM[.Pm PCYGP6H1fF aro Pmruemw.rt srtn w,aR Pu�w . Zvi uaM wv s mwn o n m ISF os�wPR �¢nn,1w-^P_[ I�y�yK4M R m^�n M I0.V[ f°TR°°l SlA/QI w ^[° . IN mnls , NOTE: v+P"°' IUM vwwn • (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2DI7 FLORIDA BUILDING CODE (2) A" MINIMUM DISTANCE FROM ANGLE LIP 10 ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF ADD LAR TILE HEIGHT AND INSULATION THICKNESS TO 4- MINIMUM HEIGHT. (3) ANCHORS TO BE MADE OF NDN-CORROSNE MATERIAL. ATABLE WITH ALUMINUM. w m� . .0 a w1RLY M 1 ��1 SN mrvnl PPODUC-fREVISED as complylug cvith the Florsd<; Building (;ode Acceptance No/ - aZ3. 9 Expitaiicn DR4e O BY Zy MD—CMA SUN-TEK MANUFACTURING, INC. AL I 0 G N4. A- 10303 GENDNAL DRbr ORLANDO. FL 32824 Engineer of Record! James D. Wells, Jr., P.E. Professional Engineer No. 53616 J & L Wells Consulting LLC 1453 Arbitus Circle Oviedo, FL 32765 (407)496-5489 Certificate of Authorization No. 27162 • DESIGN PRESSURE RATING +- 60 #10 % 2" SCREW PPH PSF LARGE MISSLE IMPACT RESISTANCE (4) ON LONG SIDE& (3) ON SHORT SIDE MINIMUM ENBEDMENT 1" RIG STI-275 O600 THICK ALUMINUM AND3WEL WELDED -JTuv 90' . MIN 4" MINIMUM SEE NOTE #2 tz (2) TER LINER .030 polyc (Polrom Palsun, Sheffield Mokrolon or Sobic Lemon 9034) US complying with the?riovida Building Code FINISHED WALL MATERIAL BY OTHERS ( APPROVED DADE COUNTY) 5-1/2" DOME RISE ipeN 516 Lo/} OF -OUTER DOME .070 POLYCARSONATE (Polrom Palsun, Sheffield Makrolon or Sobic Leman 9034) AIR FILLED INSULATED SPACE #10 x 3" DECK SCREW (4) ON LONG SIDE (3) ON SHORT SIDE - MINIMUM ENBEDMENT 5/8" NOTE: (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE DWG.11+ CMA-002 _. i SILICONE BEDDING (CONTINUOUS) (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF 2X SYP (SG 0.55) CURB HEIGHT SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT TO BE SUFFICIENT TO MAINTAIN INSULATION. FOR INSULATION AND TILE ROOF ADD 4" MINIMUM AT LOWEST POINT TILE HEIGHT AND INSULATION THICKNESS TO 4" MINIMUM HEIGHT. OF FRAME TO ROOF SURFACE SUPPLIED BY OTHERS AN (3) ANCHORS TO BE MADE OF NON -CORROSIVE MATERIAL, ROOF DECK (APPROVED BY DADE COUNTY) COMPATABLE WITH ALUMINUM. STS-1000 SEALANT (CONTINOUS) BUTYL RUBBER SEALANT BETWEEN SKYLIGHT AND CURB (continuous) rSHIM® EA, ANCHOR (TYP) WITH LOAD BEARING SHIM �_O.500 MM. 3/16" RIVET �/LONG SIDE I /SHORT SIDE FLASHING BY OTHERS IN ACCORDANCE WITH NRCA NAME, MD-CMA SUN-TEK MANUFACTURING, INC. A D _ 10303 GENERAL DRNE MAND0. FL 321324 0 \❑