HomeMy WebLinkAboutPRODUCT APPROVALa u5. a vl L
Businesst Professional1
aas Home I Ln M I pser Pe Ll Wn MTopo Sub.tSur Mu • Sul, Farts PublioVprtst g acts A4 Map llnl¢`®
db
r
Product Approval rO r 'nne
' usaa: �b110 (' (I ` " 1 SCANNED
PMa _ 1141n,,>F� ai h �> BY
A— i � > Apparauon oefaiL
FL #
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
Florida License
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated By
Certificate of Independence
Referenced. Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Sections from the Code
FL16048-R6
Revision
2017
Approved
C
Tri-Built Materials Group, LLC
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
david.miz@tribuiltmg.com
David Ruiz
david.rulz@tribuiltmg.com
David Ruiz
250Route 17 North
East Rutherford, NJ 07073
(201) 842-2449
david.mlz@tribuiltmaterlalsgroup.com
Roofing
Underlayments
of. Lucie County
APR I l 2019
�LLiCle n.,._.
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Robert Nleminen
PE-59166
UL LLC
07/18/2020
John W. Knezevich, PE
LVL Validation Checidist - Hardcopy Received
FL16048 96 COI 2017 01 Col NI ml en odf
Standard
ASTM D1970
ASTM G155
FM 4474
FRSA/rR1 April 2012 (04-12)
UL 1897
Year
2015
2005
2011
2012
2012
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=vGEVXQwtDgtFPmdYiND... 1/12/2018
Florida Building Code Online
Page 2 of 2
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
Summary of Products
Method 1 Option D
09/25/2017
10/01/2017
10/03/2017
12/12/2017
FL #
Model, Number or Name
Description
16048.1 TRI-BUILT Roof Underlayments
Self-atlhering, modified bitumen: roof underlayments
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
instructions
Approved for use outside HVHZ: Yes
EL36048 R6 II 0 FINAL ER TRi
BUILT UNDER11 2917T0 FL16048ER6 I
Impact Resistant: N/A
Design pressure: +N/A/-150
Vended By: Robert Nieminen PE-59166
Other: 1.) The design pressure noted herein pertains to use
Created by Independent Third Party: Yes
Evaluation Reports
of foam -on tile systems overtop the self -adhering
undedayment for one particular application. See ER Sectdo
ELi6048 R6 AE 2017 0 FINAL ER TRf
TR
Use. for details. 2.) Refer to ER Section 5 For other Limits of
Use.
BUILT UNDERLAYM S R '; 48 R6 vdf
Created.by Inaepentlent Third Party; Yes
Back Neat
Consna USUS::)fill8 1 Ston, Pna.lTaffnha�ft-phony; s,,,7,B24
Tie Sto ¢ V noritla k an AVEE0 employer. C00v oht 2007-201�r of nohea :: MM SM Wtpm :: A¢ TN Svdo ee :; ReruM
do rot send
`Pursuant to
:Tall add. it
fo not wish b
a 11We a under
pmdua Approval Acmpts:
®®"TE-11K®
SBCIILIL}'AIkTRICS
https://www.floridabuilding.orglprlpr app_dti-aspx?param=wGEVXQwtDgtFPmdYiND... 1/12/2018
Florida Building Code Online
Page 1 of 4
ionm
' � ..care poE �mye:oeea PprAroAlma§s, tOvidcr9si'A
0da
Product Approval
ry usea: went user
l`?-.ate v+ry %od d Anomvaj MM> Prv4utt or Aoolkatlon Sea,[h> Apmmnon llst> Appnoaaon De l
FL *
Application Type
Code Version
Application Status
Comments
Archived
Product Manufacturer
Address/Phone/Email
Authorized Signature
Technical Representative
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Florida Engineer or Architect Name who developed
the Evaluation Report
FloridaLicense
Quality Assurance Entity
Quality Assurance Contract Expiration Date
Validated. By
Certificate of Independence
FL14645-R3
Revision
2017
Approved
C
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
(502) 855-4300
dstermer@metalsalas.us.com
David Stermer
dstermer@metalsales.us.com
Roofing
Metal Roofing
Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
Evaluation Report- Hardcopy Received
Bala Sockalingam
PE-62240
Keystone Certifications, Inc.
12/27/2026
Yoosef Lavi, P.E.
G Validation Checklist - Hardcopy Received
FL1464s g3 Col C rtifcatei deoeodence:od
Referenced Standard and Year t6f Standard) Standard
FM 4470
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2012
2003
2012
2006
https://www.floridabuUding.orglpr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... '1/12/2018
Product Approval Method Method 1 Option D
Date Submitted 09/09/2017
Date Validated 09/14/2017
Date Pending FBC Approval 09/1512017
Date Approved 12/12/2017
Summary of Products
FL #
Model, Number or Name
Description
14645.1
2.5" Corrugated
Min. 26 ga., 21.33" wide coverage through fastened roof
panel over min. 19/32" thick plywood deck.
Limits of Use
Installation Instructions
1
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FI 14645 R3 li EvaluatlonRe urtC2182 odf
Verified By: Bala-Sokalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Parry: Yes
Design Pressure: +N/A/-86.0
Evaluation Reports
1
Other: Uplift load of 82.3 psf at fastener spacing.. of 36" o.c.
FL14645 R3 AE Eval atton�rtC2182 Ddf
and 86.0 psf at fastener spacing of 12" o.c.
Created by Independent Third Party: Yes
14645.2
SV-Crimp
Min. 26 ga., 24 wide through fastened roof panel over min.
19/321 thick plywood deck with fasteners through panel Bat
Limits of Use
Installatin Instructions
o
Approved for use in HVHZ: No
FI 14645 R3 11 EvalgatignRenortC2182 2 odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-149.6
Other: Uplift load of 84.5 psf at fastener spacing of 24"
Evaluation Reports
FL14645 4645 R3 AE Evaluat' nReoortC2182 2 odf
o.c., 131.3 psf at fastener spacing of 18' o.c. and 149.6 psf
Created by Independent Third Party: Yes
at fastener spacing of 12' O.C.
14645.3
SV-Crimp
Min. 26 ga., 24" wide through fastened roof panel over min.
19/32" thick plywood deck with fasteners through panel rib.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL14645 R3 IT EvaluallogRelilgiC2182 3 odf
Approvedfor use outside HVHZ: Yes
Verified By: Bala Sokalingam PE 62240
Impact Resistant- N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-196.75
Evaluation Reports
Other: Uplift load of 41.6 psf at fastener spacing of 36"
F1 14645 R3 AE r2jilluglignReportC2182 3 odf
o.c.,. 74.8 psf at fastener spacing of 16" o.c. and 196.75 psf
Created by Independent Third Party: Yes
at fastener spacing of 81 o.c.
14645.4
SV-Comp
Min. 26 go., 24" wide through fastened roof panel over min.
15/32" thick plywood deck or 7/16" thick OSB with fasteners
.through panel rib.
Limits of Use
Approved for use in HVHZ: No
Installation Instructions
FL14645 R3 If EvaluatilinilevortC2187 4 odf
Approved for use outside HVHZ: Yes
Verified By: Bala Sokalingam PE 6224U
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-172.5
Evaluation Reports
Other: Uplift load of 30.0 psf at fastener spacing of 36" o.c.
FL14645 R3 AE EvalLtlijionR§2QrtC2I82 4 ndf
and 172.5 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.5
Aluminum Classic Rib
Noon. 0.032" thick, 36" wide, aluminum through fastened
roof panel over min. I5/32" thick plywood deck or 7/16"
thick OSB.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
FL14645 R3 II EvaluatipnRe,otC2182 5 odf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-120
Evaluation Reports
5
Other: Uplift load of 30 psf at fastener spacing of 36" o.c.
FL14645 R3 AE EvaluationReDortC2182 odf
and 120 psf at fastener spacing of 6" o.c.
Created by Independent Third Party: Yes
14645.E
Aluminum Vertical Seam
Noon. thick,
wide, rl/af
de
panel over m./3Z" thick plywood k o716thick
OSB.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
FL14645 R3 II Eyalu ti Re rtC2182 6 odf
Verified By: Bala Sockalingam PE 62240
Impact Resistant: N/A
Created by Independent Third Party: Yes
Design Pressure: +N/A/-97.05
Evaluation Reports
R3 AE EvIlgiltionReportC2182 6 od
other: Uplift load of 41.6 psf at clip spacing of 36" o.c.,
FLt4645
71.0 psf at dip spacing of 12" o.c. and 97.1 psf at clip
Created by Independent Third Party: Yes
soacino of 12" o.c. with sidelao adhesive.
https://www.floridabuilding.org/pr/pr app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Florida Building Code Online
Page 3 of 4
14645.7 Aluminum Vertical Seam None. over 32" thic k, 16' wide, aluminum 9/32" thick plywood deck standing seam roof
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-162.0
Other: Uplift load of 41.6 psf at clip spacing of 36" D.C.,
100.2 psf at dip spacing of 12' D.C. and 162.0 psf at dip
spacing of 12" D.C. with support strap.
Installation Instructions
FL14645 R3 71 EvaluaUgnReg2dC2182 7.Ddf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
F. ......,3 .� e.., atlonRCg0"tr2IR2 7nnf
Created by Independent Third Party: Yes
14645.8 Classic Rib Min. 29 ga., 36' wide through fastened mof panel over min.
15/32" thick plywood deck.
Limits of Use
Approved for use In HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-91
Other: Uplift load of 41.5 psf at fastener spacing of 48' D.C.
and 91 psf at fastener spacing of 6" D.C.
Installation Instructions
Fl 14645 R3 11 EyplVatlonReportC2182 8 df
Verified By: Bala Sodkalingam PE 62240
Created by Independent Third Party: Yes
Yes
14645.9 Classic Rib Min. 26 ga., 36" wide through fastened roof panel over min.
19/32"thick plywood deck.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-133.9
Other: Uplift load of 74.8 psf at fastener spacing of 36"
o.c., 92.3 psf at fastener spacing of 24" o.c and 133.9 psf
at fastener spacing of 18' o.c.
14645.10 I Classic Rib
Limits of Use
Approved for use In HVHZ: No
Approved for use, outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-135.0
Other: Uplift load of 45 psf at fastener spacing of 24" o.c.
and 135 psf at fastener spacing of 6" o.c.
Installation Instructions
FL14645 R3 71 EvalgationlleportC2182 9 ndf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EvalugngnReDortC2182 9 odf
Created by Independent Third Parry: Yes
Min. 29 ga., 36" wide through fastened roof panel over min.
7/16" thick OSB deck
Installation Instructions
Party: Yes
Third: Party:
14645.11 Classic Rib Min. 29 ga., 36' wide through fastened roof panel over mhn.
15/32' thick plywood deck.
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-138.5
Other: Uplift load of 68.4 psf at fastener spacing of 24" D.C.
and 138.5 p5F at fastener spacing of 12" D.C.
14645.12 1 Image II
Limits of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
'Design Pressure: +N/A/-86.55
Other: Uplift load of 20.8 psF at fastener spacing of 24"
o.c., 63.5 psf at fastener spacing of 6" o.c and 86.55 psf at
fastener spacing of 6" D.C. with sidelap. adhesive.
Installation Instructions
FL1464S R3 II EvaluiIjjonReportC2182 11 odf
Verified By: Bala SDckaiingam PE 62240
Created by Independent Third Party: Yes
Evaluation Reports
FL14645 R3 AE EMaluatiOnReDOrtC2182 11 df
Created by Independent Third Party: Yes
Min. 26 ga., 16" wide concealed fastened roof panel over
min. 15/32'thick plywood deck or 7/16" thick OSB.
Installation Instructions
5 R3 11 Eval atio ReoortC2182 12 odF
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes.
Evaluation Reports
F1 14645 R3 AE F—valuatiOnReWrIZC2182 12 df
Created by Independent Third Party: Yes
14645.13 PBR-Panel or R-Panel -Min. 26 ga., 36" wide through fastened roof panel over min.
15132' thick plywood deck.
Limits Of Use
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design Pressure: +N/A/-131.0
Other: Uplift load of 30.0 psf at fastener spacing of 4B' D.C.
and 131.0 psF at fastener spacing of 6' D.C.
Installation Instructions
F114645 R3 If E al ato ReoortC2182 13 odf
Verified By: Bala Sockalingam PE 04240
Created by Independent Third Party: Yes
Evaluation Reports
F 14645 R3 A Ev-lu HonReo rtC2182 13 odf
Created. by Independent Third Party: Yes
14645.14 Pro -Panel II Min. 29 ga., 36' wide through fastened roof panel over min.
15/32" thick plywood deck.
https://vwvw.floridabuilding.org/pr/pr_app_ tI.aspx?pararn=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018
Limits of Use
Approved for use In HVHZ:-No
Approved for use outside HVHZ: Yes
Impact Resistant: N/A
Design pressure: +N/A/-71.5
Other. Uplift load of 41.6 psf at fastener spacing of 24" o.c.
and 71.5 psf at fastener spacing of 12" o.c.
eadr
Installation Instructions
FL14645 R3 II Evaivatio ReoortC2182 14 Ddf
Verified By: Bala Sockalingam PE 62240
Created by Independent Third Party: Yes
ntaG U�;; �n R E Tall M1 FL323n9 Phone, 850-482-1824
Th¢ State of Fladde k do PP/B-0emplMer. f ovridht 200r-2813 State of Fbdda: ::Privacy b'b@melK:: Pccessib8'N Statement:: ReNM Statement
Under FIOMa law, ¢mall addreses are publicm ordS. lrvou do not weetyour e-ma8 address released In re Nara ue a publlaremNs redee9, do not sand
elecoonle mall 0 Wde entity. Instead; mntad bee offim by phone or by tradidonal mal. If yw have AM ¢uesdons, please mnlea 850.482.1385. •Pursuant to
Sedlon 455.2r5(1), F1 Ma Statutes, eRerave odober I, 2012, Iimnsees lioamed underD Pter 455, F.S. must pmvlde Ne Deparbment wM an emaa address if
they have one. The emails provided ma, ce � for orfldel mmmunKadoll wM Me reamdoe. However A.9 addresses are public remM. If you do not wah m
supply a personal address, please pmvlde the Department with an enroll address whin mn M made available W the public To determine If We are a licensee under
'Uapter 455, F.S., please dhkbe(d.-
PmductApproyal AcPbpa
®®®WlM
Credit Card
Safe
https://www.floridabuilding.org/pr/pr_app_dtl.aspx?param=wGEVXQwtDgsw8ZVNfe8A... 1/12/2018