EVALUATION REPORT
Manufacturer:
GACO WESTERN, LLC
- --
200 West Mercer Street, Suite 202
Seattle, WA 98119
(800) 331-0196
www.gaco.com
Manufacturing Plant:
Waukesha, WI
Quality Assurance:
UL LLC (QUA9625)
SCOPE
Category:
Subcategory:
Code Sections:
Properties:
PRODUCT DESCRIPTION
Certificate of Authorization No. 29824
SCANNED
BY
St. Lucie County
17520 Edinburgh Dr
Tampa, FL33647
(813)480-3421
FLORIDA BUILDING CODE, 6'a EDITION
Roofing
Spray Applied Polyurethane Roof System
1507.14.2, 1507.14.3, 1515.1.1, 1515.1.4, 1519.16, 1523.6.2
Wind Resistance, Physical Properties
Issued December 11, 2018
Product
Description
rG-'nc�@o'ufF m m 3
TAS 110 and ASTM C 1029 Type III polyurethane spray applied foam that utilizes an
HFC blowing agent intended for roofing applications.
GacoFlex A-31
ASTM D 6083 acrylic quick -set elastomeric coating that is brush, roller or spray -applied.
GacoFlex S-10
ASTM D 6694 silicone elastomeric coating that is brush, roller or spray -applied.
�GacoF.lex S'-20)
-ASTMtV66 i)t94'Ts 'cc' oeMo—iveni--fre'g sln'gle-componentFmdisture— cure waterproof
astome=oa iingt a Is brush olteriorispraynappD�d.
GacoFlex S-21
ASTM D 6694 silicone solvent -free, single -component, moisture -cured, waterproof
elastomeric coating that is brush, roller or spray -applied.
GacoRoof GR-16
ASTM D 6694 silicone elastomeric coating that is brush, roller or spray -applied.
REFERENCES
Entity
Report No.
Standard
Year
Intertek Testing Services NA, Inc. (TST6781)
102205114MID-001
ASTM C 1029
2013
TAS 110
2000
FM Approvals (TST1867)
3023644
FM 4470
2012
FM Approvals (TST'I867)
3052963
FM 4470
2012
PRI Construction Materials Technologies (TST5878)
GWI-024-02-02
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-026-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-042-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-043-02.01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-044-02-01
ASTM D 6694
2008
PRI Construction Materials Technologies (TST5878)
GWI-045-02-01
ASTM D 6083
2005e01
PRI Construction Materials Technologies (TST5878)
GWI-045-02-01
Proprietary
2017
PRI Construction Materials Technologies (TST5878)
GWI-052-02-01
ASTM D 2126
2015
TAS 110
2000
PRI Construction Materials Technologies (TST5878)
GWI-057-02-01
ANSI/FM 4474(D)
2011
TAS 114(J)
1995
PRI Construction Materials Technologies (TST5878)
GWI-057-02-02
ANSI/FM 4474(B)
2011
TAS 114(D)
1995
PRI Construction Materials Technologies (TST5878)
GWI-060-02-01
ANSI/FM 4474(B)
2011
TAS 114(D)
1995
PRI Construction Materials Technologies (TST5878)
GWI-060-02-02
ANSI/FM 4474(D)
2011
TAS 114(J)
1995
GW18001.1 FL14723-R5 Pace 1 of
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CRE E �j GWESTERN
II�-CC II11 SSprayy Applied PolyurethaneG Roof Systems
TECHNICAL SERVICES, LLC
Entity
Report No.
Standard
Year
PRI Construction
Materials Technologies (TST5878)
GWI-060-02-03
ANSI/FM 4474(0)
2011
TAS 114(J)
1995
PRI Construction
Materials Technologies (TST5878)
GWI-060-02-04
ANSI/FM 4474(D)
2011
TAS 114(J)
1995
PRI Construction
Materials Technologies (TST5878)
GWI-067-02-02
ANSI/FM 4474(B)
2011
TAS 114(D)
1995
PRI Construction
Materials Technologies (TST5878)
GWI-067-02-02A
ANSI/FM 4474(B)
2011
TAS 114(D)
1995
UL LLC (TST9628)
R5663
UL790
2004
LIMITATIONS
1. Fire classification is not within the scope of this evaluation.
2. The roof deck and the roof deck attachment shall be designed by others to meet the minimum design loads
established for components and cladding and in accordance with FBC requirements.
3. Foam plastic insulation shall be installed in accordance with the FBC Section 2603.3, 2603.4 and 2603.6.
4. Spray polyurethane foam shall not be applied when ambient temperature is within 5 degrees of the dew
point. Ambient humidity applications limits shall be as listed in Table 1 below. In the HVHZ, the contractor
shall monitor and record environmental conditions in the Job Log in compliance with RAS 109. Job Log
shall be maintained at the job site and accessible to The Building Official.
5. All attachment and sizing of perimeter nailers, metal profile, and/or flashing termination designs shall
conform to ANSI/SPRI ES-1 (non-HVHZ only) or Roofing Application Standard RAS 111 and the wind load
requirements of Chapter 16.
6. In the HVHZ, fastener spacing for base sheets or membrane attachment shall meet the minimum fastener
resistance value and the MDP for the specified assembly. It is permissible for a qualified professional to
submit a revised fastener spacing utilizing the withdrawal resistance value obtained from TAS 105 testing
and calculations performed in accordance with RAS 117 and/or RAS 137, when the fastener resistance is
found less than required.
7. For assemblies containing mechanical attachment, the allowable uplift pressure for the selected assembly
shall meet or exceed the minimum design loads as determined in accordance with the FBC Chapter 16. For
perimeter and corner roof zones 2 and 3, the attachment density may be increased by a qualified design
professional, as necessary, to meet the design pressure requirements in these areas. In the HVHZ,
calculations shall be conducted in compliance with RAS 117 and/or RAS 137. Outside the HVHZ,
commonly used standards include RAS 117, FM LPDS 1-29, or ANSI/SPRI WD-1.
8. Reroofing applications shall be examined in accordance with FBC Section 1511 outside of the HVHZ and
FBC Section 1521 within the HVHZ. For mechanically fastened systems, a field withdrawal resistance test
(TAS 105 in the HVHZ; ANSUSPRI FX-1 or TAS 105 in the non-HVHZ) shall be conducted by a qualified
professional to ensure the fastener meets the minimum design load requirements of the system. For
adhered systems, a field uplift resistance test (TAS 124 in the HVHZ; ASTM E 907, FM LPDS 1-52,
ANSI/SPRI IA-1, or TAS 124 in the non-HVHZ) shall be conducted to confirm conformance of the existing to
the minimum design loads.
9. The MDP for the selected roof system shall meet or exceed the minimum design loads as determined in
accordance with the FBC Chapter 16 without augmentation.
10. Flashings and waterproof coverings for expansion joints shall be of compatible materials and according to
the sprayed polyurethane foam manufacturer's published literature.
11. Miscellaneous materials such as adhesives, elastomeric caulking compounds, metal, vents and drains shall
be a composite part of the roof system and shall be compatible with the foam and coating.
12. Installation of the evaluated products shall comply with this report, the FBC, and the manufacturer's
published application instructions. Where discrepancies exist between these sources, the more restrictive
and FBC compliant installation detail shall prevail.
13. The minimum roof slope shall be in accordance with the FBC.
14. All products listed in this report shall be manufactured under a quality assurance programs in compliance
with Rule 61G20-3.
GW18001.1 FL14723-R5 Paae 2 of 4
This evaluation report is provided for Stale of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GACO WESTERN
Spray Applied Polyurethane Roof Systems
Table 1. Ambient Humidity Applications Limits -
Air Temp! Humidity/ Dew Point Guideline
110
100
90
lu Air Temp
a Humidity
t Dew Point
80
70
60
50
4D
30
45
67
140.5
50
1 70
145.5
1 55
1 72
150.5
1 60
1 75 155.5
is
45
50
55
60
165
170
75
180
85
90
1 95
1 100
a
67
70
112
175
178
180
78
175
70
64
1 58 1
50
40.5
1 45.5
150.5
1 55.5
1 60.5
65.5-
1 70
I 73.5
1 77
179.5
1 82
1 83
Dew point and relative humidity forgiven dry bulb temperature.
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report Is valid.
This evaluation report does not express nor imply warranty, Installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
COMPLIANCE STATEMENT
GACO WESTERN
Spray Applied Polyurethane Roof Systems
The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building
Code, 6m Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer.
till I I I I I 11111j,
No 74021
Cam. * •rT:
10'.• STATE OF :��r
S/ONA� E�.%
CERTIFICATION OF INDEPENDENCE
2018.12.11
15:29:34
-05 00
Zachary R. Priest, P.E.
Florida Registration No. 74021
Organization No. ANE9641
CREEK Technical Services, LLC does not have, nor will it acquire, a financial interest in any company manufacturing or distributing
products under this evaluation.
CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under
this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial Interest In any company manufacturing or distributing products
under this evaluation.
Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
APPENDICES
1) APPENDIX A — Installation and Nomenclature (3 pages)
2) APPENDIX B —Approved Assemblies (3 pages)
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GACO WESTERN
Spray Applied Polyurethane Roof Systems
APPENDIX A
INSTALLATION
Note - Refer to the APPROVED ASSEMBLIES section of this report for specific installation details of a selected assembly.
Unless otherwise specified in this report the following installation details shall be met for the named products:
Use _ _
Products
Description and Installation
GAF GAFGLAS
Stratavent
ASTM D 4897, Type II perforated base sheet; granule -surfaced on the bottom of
Perforated Venting
sheet. Min. 2-inch side laps
Base Sheet
Base Sheet
Firestone MIS Base
ASTM D 4601, Type II base sheet; Min. 3-Inch side laps
Firestone SBS Base
ASTM D 6163, Type 1, Grade S base sheet; Min. 3-Inch side laps
Board Adhesives
Firestone I.S.O.
Twin Pack
Applied in 3/4-inch wide ribbons
Fasteners &
Firestone All-
Purpose Fasteners
Min.0.75-inch penetration through the top rib of the steel deck or wood deck
Plates
Firestone Insulation
Fastening Plate
3-inch diameter; Galvalume steel plate
Cellular
Lightweight
Concrecel
Slurry coat min. 1/4-Inch thick; 1" thick EPS Holey board (1 Ibs/ft'); Min. 2-inch thick
Concrete
topcoat; Min. f. at 28 days as stated in the Approved Assemblies
Georgia-Pacific
DensDeck Prime
Min. 1/2-inch thick
Roof Board
USG SECUROCK
Gypsum -Fiber Roof
Min. 112-inch thick
Board
GacoFlex E-5320
Two component water based epoxy primer composed of Part A and Part B; shall be
Primer
reduced with 1 pint of water per gallon of primer and roller applied to surface
GacoFlex A4600
Water -borne acrylic roof coating that is brush, roller or spray -applied at a minimum
rate of 1 gal/l 00 it
o yurethane
CGacogoafFoam
Uniformly applied over surface to a minimum thickness of 1-Inch
,oam
72��.ZZ333311
GacoFlex A-31
Acrylic quick -set elastomeric coating that is brush, roller or spray -applied in three (3)
coals at a minimum total rate of 1.5 gal/100 ft'
GacoFlex S-10
Silicone elaslomeric coating that is brush, roller or spray -applied in one (1) or two
(2) coats at a minimum total rate of 2.2 ga11100 ft'
Silicone solvent -free, single -component, moisture -cured, waterproof elaslomeric
-nafingS
aco �tez�S-2.
coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum
total rate of 1.5 gal/100 e
Silicone solvent -free, single -component, moisture -cured, waterproof elastomerc
GacoFlex 5-21
coating that is brush, roller or spray -applied in one (1) or two (2) coats at a minimum
total rate of 1.5 gal/100 ft'
GacoRoof GR-16
Silicone elastomerc coating that is brush, roller or spray -applied in one (1) or two
(2) coats at a minimum total rate of 2.0 ga11100 ft'
GW18001.1 FL14723-R5 Pace 1 of 3
This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GACO WESTERN
Spray Applied Polyurethane Roof Systems
APPENDIX A
Insulation/Cover Board Fastening Patterns
Description
_ .....Fastening Pattern
4
OO Oa
16 per
4ft.x8ft.
board
m
0 O
r
(Max. 2ft2 contributory area per fastener)
sa
20 per
4 ft. x8 ft.IIl—
board (1)
m�
tom` V O O
(Max. 1.6ft2 contributory area per fastener)
to
O 6-O O O O
20 per
4 ft. x8ft.
v
board (2)
O O ® O
N yal
O Q O
to
(Max. 1.6ft2 contributory area per fastener)
GW18001.1 FL14723-R6 Paqe 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
i` CREEK Ge Roof
WESTERN
�s G �r II11 Spray Applied Polyurethane Roof Systems
TECHNICAL SERVICES, LLC APPENDIX A
NOMENCLATURE
The following naming conventions are utilized to specify products in the APPROVED ASSEMBLIES section of this report.
Refer to the nomenclature below when deciphering the allowable products for use in the selected assembly.
Installation requirements shall be as noted in the APPROVED ASSEMBLIES and INSTALLATION section of this report.
Name -;
Definition ,
As Tested
Information provded to the report user based on the as tested condition of the system
oa m
One of the following:
-GaceFlex A-31
-GacoFlex 8-10
Mg@FrS_
-GaceFlex S-21
-GacoRoof GR-16
Designed by others in accordance with FBC requirements; As Tested deck construction details are described
as follows:
Concrete Deck
_
Min. f, = 2,500 psi at 28 days.
CWFDeck
Min. 2.5-inch thick_Tectum I cemenlitious wood fiber panels
IR-ec-a-ve-rIft
Where assemblies are used to recover an existing roof, the existing roof shall consist of
only one layer of roofing, i.e. recovering a previously recovered roof is not permitted.
Recover roofing shall be conducted in compliance with FBC Section 1511.
ck - etai!
Steel Deck
Min. 22 ga, ASTM A 653 G90, Grade 33, Wide Rib Deck (Type WR) conforming to
ANSI/SDI-RD1.0 & FBC;
The following nomenclature is used to further describe the As Tested condition.
F<#>
<#> #12-24 HWH self -drilling screws or equivalent fastener at each flute used to
secure the deck to the structural supports; Min. 0.25-inch penetration
G<#>
I Min. Grade <#> of Steel Deck
L<#>-1
Max. span of <#.> inches
S<#>
114 --14 HWH x7/8" self -drilling screws or equivalent fastener secured <#>-inch
o.c._along the panel side laps
Wood Deck
_
Min. PS 1-09 plywood sheathing; APA Span -Rated. Fasteners and stress plates shall be
attached as follows:
_
The following nomenclature is used to further describe the As Tested condition.
T<#>
Min. <#>-inch thick plywood
L<#>
Max. span of <#> inches
N<#>
Min. 8d ring shank nails spaced <#>-inch o.c. at the field and perimeter
MDP
Maximum Design Pressure
GW18001.1 FL14723-R5 Pace 3 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
APPROVED ASSEMBLIES
GACO WESTERN
Spray Applied Polyurethane Roof Systems
APPENDIX B
The following notes shall be observed when using the assembly tables below.
1. Allowable pressures (MDP) were calculated using a 2:1 margin of safety per FBC Section 1504.9.
2. Refer to LIMITATIONS and NOMENCLATURE sections of this evaluation when using the table(s) below.
3. Refer to INSTALLATION section of this report for installation detail when the information is not explicitly stated
for the selected assembly.
4. As Tested information for roof deck construction is provided for information only. The addition of the As
Tested deck information does not obviate the requirement for rational design of the roof deck and roof deck
attachment in accordance with FBC requirements.
-`
Deck Detail
Anchor Sheet, Roof Board, and/or
Primer
Polyurethane "'Protective
°.
MDP
Lightweight Concrete
Foam.
Coatin
(PS "
Concrete Deck
_
_
GacoRoofFoam
Coating
435
2733
Lim. 9
222.5
CWF Deck
_
_
GacoRoof oam
Coating
(HIH 9'
onl
Gypsum Deck _ _ GacoRoofFoam I Coating -222.5
2733 I'm. 9)
Min. 460psi Concrecel followed by
1/2-inch USG SECUROCK Gypsum -
Steel Deck;
Fiber Roof Board attached with
GacoRoofFoam
-so
G33, L6, P, SIB
Firestone All -Purpose Fasteners and
-
2733
Coating
(Lim. 7)
Insulation Fastening Plates at rate of
16 per 4-ft x 8-ft board
l fastener per 21t
Recover
over existing smooth surface
_
_
GacoRoofFoam
Coating
-135
BUR roof system with
2733
(Lim. 9)
Concrete Deck
Recover
over existing granule surface SBS
-
_
GacoRoofFoam
Coating
-155
Mod Bit roof system with
2733
(Lim. 9)
Concrete Deck
Recover
over existing gravel surface BUR
-
-
GacoRoofFoam
Coating
-220
roofs stem with Concrete Deck
2733
(Lim. 9)
Recover
over existing sanded surface APP
_
_
GacoRoofFoam
Coating
-430
Mod Bit roof system with
2733
(Lim. 9)
Concrete Deck
Recover
over existing granule surface APP
_
_
GacoRoofFoam
Coating
-502.5
Mod Bit roof system with
2733
(Lim. 9)
Concrete Deck
Recover
over existing sanded surface SBS
-
-
GacoRoofFoam
Coating
-502.5
Mod Bit roof system with
2733
(Lim. 9)
Concrete Deck
Recover
over existing smooth surface
-
-
GacoRoofFoam
Coating
-90
BUR roofs stem with Steel Deck
2733
(Lim. 9)
Recover
over existing smooth surface APP
-
-
GacoRoofFoam
Coating
1106
-106.5
Mod Bit roof system with
2733
( 9)
Steel Deck
FL1
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
CREEK
TECHNICAL SERVICES, LLC
GACO WESTERN
Spray Applied Polyurethane Roof Systems
APPENDIX B
Deck Detail
Anchor Sheet, Roof Board, and/or
Primer
Polyurethane
Protective
MDP
Lightweight Concrete
Foam
Coating
s
Recover
over existing gravel surface BUR
-
-
GacoRoofFoam
Coating
-155
roofs stem with Steel Deck
2733
(Lim. 9)
Recover
over existing smooth surface SBS
-
_
GacoRoofFoam
Coating
•162.5
Mod Bit roof system with
2733
(Lim. 9)
Steel Deck
Recover
over existing granule surface APP
_
_
GacoRoofFoam
Coating-167.5
Mod Bit roof system with
2733
(Lim. 9)
Steel Deck
Recover
over existing granule surface SBS
_
_
GacoRoofFoam
Coating
•292.5
Mod Bit roof system with
2733
(Lim. 9)
Steel Deck
1/2-inch Georgia Pacific DensDeck
Prime attached with Firestone All -
Steel Deck;
Purpose Fasteners and Insulation
_
GacoRoofFoam
Coating
-75
G33, L6, P, S24
Fastening Plates at a rate of
2733
(Lim. 7)
20 per 4-R x 8-B hoard (2)
1 fastener er 1.6ft'
�B"0_20
_
lGadbRobfFba
>�
Adilluffn
p
1/2-inch Georgia Pacific DensDeck
Prime attached with Firestone All -
Steel Deck;
Purpose Fasteners and Insulation
_
GacoRoofFoam
Coating
-97'S
G33, L6, F1, S24
Fastening Plates at a rate of
2733
(Lim. 7)
20 per 4-ft x 8-R board (2)
l fastenerper1.6ft'
Steel Deck;
_
_
GacoRoofFoam
Coating
-105
G33, L6, F1, S24
2733
Lim. 9
1/2-Inch DensDeck Prime secured
-147.5
Steel Deck
6-inch o.c. in Firestone I.S.O. Twin
_
GacoRoofFoam
Coating
(Lim. 9;
Pack Insulation Adhesive to the top
2733
HVHZ
flange of the deck ribs
only)
-407.5
Steel Deck
_
_
GacoRoofFoam
CoLim.
ating
(Lim.9
only)
Wood Deck;
T19/.32, N6, L24
Firestone MB Base attached with
Firestone All -Purpose Fasteners and
Insulation Fastening Plates spaced 12-
inch o.c in the lap and 12-Inch o.c, in
two 2 staggered rows in the field
-
Gaco2733 am
2733
Coating
-67,5
(Lim. 7)
Firestone SBS Base attached with
Wood Deck;
Firestone All -Purpose Fasteners and
GacoFlex
GacoRoofFoam
-67.5
T19l32, N6, L24
Insulation Fastening Plates spaced
A-0600
2733
Coating
(Lim. 7)
inch o.c in the lap and 12-Inch o.c. in
in
two 2 staaaered rows in the field
1/2-inch Georgia Pacific DensDeck
Prime attached with Firestone All -
Wood Deck;
Purpose Fasteners and Insulation
GacoFlex
GacoRoofFoam
Coating
T19132, N6, L24
Fastening Plates at a rate of
A4600
2733
20 per 441 x 8-ft board (1)
1 fastener per 1.6ft'
GW18001.1 FL14723-R5 Pace 2 of 3
This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.
F- CREEK
TECHNICAL SERVICES, LLC
GACO WESTERN
Spray Applied Polyurethane Roof Systems
APPENDIX B
Deck Detail
Anchor Sheet, Roof Board, and/or
Lightweight Concrete
Primer
Polyurethane
Foam
Protective
Coating
MDP
s
GAF GAFGLAS Stratavent Perforated
Venting Base Sheet attached with
-105
Wood Deck;
11ga. x 1-1/4-inch ring shank nails and
GacoFleacoFle x
GacoRoofFoam
(Lim. 9
T19132, N6, L24
32 ga. x 1-5/8-inch diameter tin caps
E-5320Non-
2733
Coating
spaced 7-inch o.c in the lap and 7-inch
HVHZ)
o.c. in two (2) staggered rows in the
field
END OF REPORT
This evaluation report is provided for State of Florida product approval under Rule 61620-3. the manufacturer shall notify GREEK
Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid.
This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not
specifically addressed herein.