HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM 405-10 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: STINNETTE ADDITION Street Builder Name: SCANNED 10303 S. INDIAN RIVER DRIVE Permit Office: City, State, Zip: FT. PIERCE, FL, Permit Number: BY Owner. Jurisdiction: St. Lucie County Design Location: FL, Fort Pierce 1. New construction or existing Addition 9. Wall Types (1 o24.o sgft.) Insulation Area 2. Single family or multiple family Mule -mmily a. Frame -Wood, E)derior R=19.0 . 1024.00 ff 3. Number of units, if multiple family 1 b. N/A R= ft2 4. Number of Bedrooms(Bedrms In Addition) 2(0) c. WA d. WA R= ft= 5. Is this a worst case? No 10. Ceiling Types (1182.0 sqft.) R= ft2 Insulation Area 6. Conditioned floor area above grade (ft2) 1182 a. Under Attic (Vented) b. WA R=30.0 1182.00 ft' R= ft2 CondNoned floor area below grade (ft2) 0 c. N/A R= ftZ 7. Windows 172.0 p ( sgfL) Description Area 11. Ducts a. Sup: Attic, Rat Attic, AH: Attic R 112 6 205 a. U-Factor: Sgl, U�.78 172,00 ft2 SHGC: SHGCro.50 b. U-Factor: WA ft2 12. Cooling systems kBh to Efficiency SHGC: a. Central Unit 35.2 SEER:16.00 c. U-Factor: WA fP SHGC: d. U-Factor. NfA fJ2 13. Heating systems kBtulhr Efficiency SHGC: a. Electric Strip Heat 17.0 COP:1.00 Area Weighted Average Overhang Depth: 2.000 ft. Area Weighted Average SHGC: 0.500 14. Hot water systems - None required 8. Floor Types (1182.0 sgfL) Insulation Area a. Cap: WA a. Slab -On -Grade Edge Insulation R=0.0 1182.00 fI2 b. WA b. Conservation features EF: 0.000 R= fF c. WA R= ft' 15. Credits Pstat Glass/Floor Area: 0.146 Total Proposed Modified Loads: 16.88 Total Standard PASS Reference Loads: 21.14 I hereby certify that the plans and specifications covered by calculation Review of the plans and -VUE sT ATFO are in compliance with the Florida Energy specifications covered by this = Coda.this calculation indicates compliance y0� PREPARED with the Florida Energy Code. tr DATE: Before construction is completed this building will be inspected for compliance with Section 553.908 I hereby certify that this building, as designed, is in Compliance Florida Statutes, e tiCOD with the Florida Energy Code. tNE�� OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: 6241201512:08 PM EnergyGaugee USA - FlaRes2010 Section 405.4.1 Compliant Software Page 1 of 6 PROJECT 'Titre: Building Type: STINNETTE ADDITION Bedrooms: 2 User Address Type: Street Address Conditioned Area: 1182 Lot # Owner: # of Units: 1 Total Stories: 1 Block/SubDivision: Builder Name: Worst Case: No PlatBook: Permit Office: Rotate Angle: D Street: 10303 S. INDIAN RIVE Jurisdiction: Cross Ventilation: No County: ST. LUCIE COUNTY Family Type: Multi -family Whole House Fan: Yes City, State, Zip: FT. PIERCE, New/Eristing: Addition FL Comment: CLIMATE Design Location IECC Design Temp Int Design Temp Heating TMY Site Design Daily Temp Zone 97.5 % 2.5 % Winter Summer Degree Days Moisture Range — FL, Fort Pierce FILST LUCIE_CO_INTL 2 39 90 70 75 722 62 Low BLOCKS Number Name Area Volume 1 Blockl 1182 9456 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Main 1182 9456 Yes 2 2 1 Yes Yes Yes —# FLOORS Floor Type Space Perimeter R-Value Area 1 Slab-0n-Grade Edge Insulate Main 145 ft Tile Wood Carpel 0 11 g2 ft, -- 0 0 1 ROOF # Type Roof Gable Roof Solar Materials SA Emitt Emitt Deck Pitch Area Area Color Absor. Tested Tested Insul. (deg) — 1 Hip Metal 1280 ft' 0 fit' Medium 0.96 No 0.9 No 0 22.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC _. 1 Full attic Vented 300 1182 fN N N CEILING # Ceiling Type Space R-Value Area Framing Frac Truss Type — 1 Under Attic (Vented) Main 30 1182 ft' 0.11 Wood FILE COPY 6/24/2015 12:08 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 2 of 5 WALLS Adjacent Cavity Width Space _Sheathing Height Framing Solar Below i N _ 2 N _ 3 N 4 N Exterior Frame - Wood Exterior Frame -Wood Exterior Frame -Wood Exterior Frame - Wood Main 19 30 Main 19 34 Main 19 30 Main 19 34 8 a 8 8 240.0 ft' 0 272.0ft' 0 240.011' 0 272.0 fP 0 0 0.75 0 6.7s 0 0.75 0 0.75 0 o 0 0 DOORS # 1 2 Omt N N Door Type Space Storms Insulated Main None Insulated Main None U-Value Width Ft In .46 .3 .46 3 Height Ft In 6 8 6 8 ,area 2 IF 20 fF WINDOWS Orientation shown is the entered, Proposed orientation. Wall # 1 2 3 4 5 6 7 8 Omt ID Frame N 1 Metal N 1 Metal N 2 Metal N 3 Metal N 4 Metal N 4 Metal N 4 Metal N 2 Metal Panes NFRC U-Factor SHGC Single (Tinted) Yes 0.79 0.5 Single (Tinted) Yes 0.79 0.5 Single (Timed) Yes 0.79 0.5 Single (Tinted) Yes 0.79 0.5 Single (Tinted) Yes 0.79 0.5 Single (Tinted) Yes 0.79 0.5 Single (Tmted) Yes 0.79 0.5 Single (Tinted) Yes 0.79 0.5 Area 24.0 ft2 9.0 fF 15.0 ft' 80.0 fN 30.0 ft' 8.0 112 3.0 IF 3.0 ft' Overhang Depth Separation 2 It 0 in 6 ft 0 in 2 ft 0 in 6 ft 0 in 2 ft 0 in 6 ft 0 in 2 it 0 in Eft 0 in 2 ft 0 in 6 it 0 in 2 It 0 in 6 It 0 in 2 ft 0 in 6 It 0 in 2 ft 0 in 6 It 0 in Int Shade Drapes/brinds Drapes/blinds Drapes/blinds Drapes/brinds Drapes/blinds Drapes/blinds Drapes/blinds Drapes/blinds Screening None None None None None None None None INFILTRATION # Scope 1 Wholehouse Method Best Guess SLA .0005 CFM 50 ELA EgLA 15502 85.1 160.05 ACH ACH 50 .365 9.8363 HEATING SYSTEM # 1 System Type Electric Strip Heat Subtype None Efficiency COP:1 Capacity 17 kBtu/hr Block 1 Ducts sys#1 COOLING SYSTEM # 1 System Type Central Unit Subtype None Efficiency SEER: 16 Capacity Air Flow SHR Block 352 kBbAr 1056 cfm 0.75 1 Ducts sys#1 FILE COPY 6/24201512:08 PM EnergyGauge® USA - FlaRes2010 Section 405.4.1 Compliant Software Page 3 of 5 SOLAR HOT WATER SYSTEM FSEC Cert # Company Name System Model # Collector Collector Storage Model # Area Volume FEF ft' DUCTS _ / V # — Supply Location R-Value Area — Return— Location Area Air CFM 25 CFM25 HVAC # Leakage Type Handier TOT OUT QN RLF Heat Cool 1 Attic 6 205 ft' Attic 25 R' Default Leakage Attic (Default) (Default) 1 1 TEMPERATURES Programable Thermostat Y Ceiling Fans: Cooling [[ �Jan Heating [X]Jan VenBng Man Jan [[ ]] Feb j�rXJ,] [X]Feb l�l [L )I Feb [X] Mar Mar r � Er Apr [ I Ma r[[X Jun rX� y r Julj May [ Jon rlAu Sep ri Sep Oct Oct Nov H Dec H l I 1 Jul [ AugA Nov Dec Thermostat Schedule: HERS 2006 Reference Schedule Type 1 2 3 Hours 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 PM 80 78 80 78 78 78 78 78 78 78 78 80 80 80 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 80 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 78 78 76 78 78 78 Heating (AID) AM 66 66 66 66 78 78 78 78 PM 68 68 68 66 68 68 68 68 68 68 68 68 66 66 66 Heating (WEH) PM 66 66 66 68 66 66 68 68 68 68 68 68 68 68 68 68 68 68 68 66 66 6/24/201512:08 PM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 4 of 5 FORM 405-10 Florida Code Compliance Checklist Florida Department of Business and Professional Regulations Residential Whole Building Pprfnrmnnr-o nee+l,,,a ....�..vv ��• IIVV ADDRESS: 10303 S. INDIAN RIVER DRIVE PERMIT #: FT. PIERCE, FL, MANDATORY REQUIREMENTS SUMMARY - See individual code sections for full details COMPONENT SECTION SUMMARY OF REQUIREMENT(S) CHECK Air leakage 402.4 To be caulked, gasketed, weatherstripped or otherwise sealed. Recessed lighting IC -rated as meeting ASTM E 283. Windows and doors = 0.30 cfm/sq.ft. Testing or visual inspection required. Fireplaces: gasketed doors & outdoor combustion air. Must complete envelope leakage report or visually verify Table 402.4.2. Thermostat & 403.1 At least one thermostat shall be provided for each separate heating controls and cooling system. Where forced -air furnace is primary system, programmable thermostat is required. Heat pumps with supplemental electric heat must prevent supplemental heat when compressor can meet the load. Ducts 403.2.2 All ducts, air handlers, filter boxes and building cavities which form the primary air containment passageways for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section 503.2.7.2 of this code. 403.3.3 Building framing cavities shall not be used as supply ducts. Water heaters 403.4 Heat trap required for vertical pipe risers. Comply with efficiencies in Table 403.4.3.2. Provide switch or clearly marked circuit breaker (electric) or shutoff (gas). Circulating system pipes insulated to = R-2 + accessible manual OFF switch. Mechanical 403.5 Homes designed to operate at positive pressure or with mechanical ventilation ventilation systems shall not exceed the minimum ASHRAE 62 level. No make-up air from attics, crawlspaces, garages or outdoors adjacent to pools or spas. Swimming Pools 403.9 Pool pumps and pool pump motors with a total horsepower (HP) of =1 6 Spas HP shall have the capability of operating at two or more speeds. Spas and heated pools must have vapor -retardant covers or a liquid cover or other means proven to reduce heat loss except if 70% of heat from site -recovered energy. Off/timer switch required. Gas heaters minimum thermal efficiency=78% (82% after 4/16113). Heat pump pool heaters minimum COP= 4.0. Cooling/heating 403.6 Sizing calculation performed & attached. Minimum efficiencies per equipment Tables 503.2.3. Equipment efficiency verification required. Special occasion cooling or heating capacity requires separate system or variable capacity system. Electric heat >10kW must be divided into two or more stages. Ceilings/knee walls 405.2.1 R-19 space permitting. FILE COP'9)., 6241201512:08 PM EnergyGauge® USA- FlaRes2010 Section 405.4.1 Compliant Software Page 5 of 5 ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 80 The lower the EnergyPerformance Index, the more efficient the home. 10303 S. INDIAN RIVER DRIVE, FT. PIERCE, FL, 1. New construction or existing 2. Single family or multiple family 3. Number of units, if multiple family 4. Number of Bedrooms 5. Is this a worst case? 6. Conditioned floor area (W) 7. Windows'* Description 9. U-Factor. SDI, U-0.79 SHGC: SHGC=0.50 b. U-Factor: MA SHGC: c. U-Factor. MA SHGC: d. U-Factor: MA SHGC: Area Weighted Average Overhang Depth: Area Weighted Average SHGC: B. Floor Types a. Slab -On -Grade Edge Insulation b. N/A c. WA Addition Mufti -family 1 2(0) No 1182 Area 172.00 ft' ft' ft' ft' 2.000 ft 0.500 Insulation Area R=0.0 1182.00 ft' R= ft' R= 112 9. Wall Types a. Frame - Wood, Exterior b. WA c. WA d. N/A 10. Calling Types a. Under Attic (Vented) b. NIA c. WA 11. Ducts a. Sup: Attic, Rat: Attic, AH: Attic 12. Cooling systems a. Central Unit 13. Heating systems a. Electric Strip Heat 14. Hot water systems - None required a. b. Conservation features 15. Credits I certify that this home has complied with the Florida Energy Efficiency Code for Building Construction through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL Display Card will be completed based on installed Code compliant features. Builder Signature: Address of New Home: Date: City/FL Zip: Insulation R=19.0 R= R= R= Insulation R=30.0 R= R= Area 1024.00IF ft' fP fN Area 1182.00 ft= ft2 ft' R ft' 6 205 kBhAr Efficiency 35.2 SEER:16.00 kBhdltr Efficiency 17.0 COPA.00 Cap: NIA EF: Pstat *Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321) 638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's support staff. "Label required by Section 303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. EnergyGaugee USA- FlaRes2010 Section 405.4.1 Compliant Software FILE COPY Project Summary Date: -F- wrightsoft Entire House By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phons 772-4665799 Fax M-4666796 Email: QUIQ(CALCSOADI-COM Proiect Information For. MR & MRS KEVIN STINNETTE 10303 S. INDIAN RIVER DRIVE, FT. PIERCE, FL Notes: -Design/ / Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range L Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 17709 Btuh Structure 21156 Btuh Ducts 4362 Btuh Ducts 3268 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 22071 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 23202 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2179 Btuh Ducts 2104 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 1182 1182 Equipment latent load 4283 Btuh Volume (W) 11111 11111 Air changesthour 0.45 0.23 Equipment total load 27485 Btuh Equiv. AVF (cfm) 83 43 Req. total capacity at 0.70 SHR 2.8 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade CARRIER AIR CONDITIONING Model Cond CA16NA036""A AHRI ref Coil FX4DN(B,F)049L AHRI ref 6937948 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 5.0 kW Sensible cooling 24640 Btuh Heating output 17061 Btuh Latent cooling 10560 Btuh Temperature rise 13 OF Total cooling 35200 Btuh Actual airflow 1173 cfm Actual airflow 1173 cfm Air flow factor 0.053 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.85 Calculations approved byACCAto meet all requirements of Manual J .,t;. + wrightSOft RlghtSUWD Univemal 201515.0.02 RSLW101 AM\ ... WMNQUIckCal=%DowmeMa\STINNETTE,KEVIN.mp Calo=MJ6 Fwd Coorfaces N +-wrightsott• Right-JO Worksheet Job: Entire House Date: ey. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466.6799 Fax 772-4666796 Email: QUIQCQLLCS@ADL.COM 1 Room name Emim House NEW OFFICE 2 Figosed wall 164.0 It 15.0 It 3 Room Freight 9.4 It d 9.4 It heat/cool 4 5 Room dimensions Room area 11820 ft' 1.0 x 116.0 it 116.0 ft' Ty Contraction Uwalue Or HTM Area (M Load Area Load number (Btuh/ftx°F) (Btuwft2) or perimeter (ft) (13tuh) or perimeter (ft) (Btuh) Heat TC.1 Grass N/P/S Heat Cool Gross N/P/S Heat Cool 6 lQ/ 12E-0sw - 0.068 n -1,90 - 1.35 489 453 ° 863 -. 613 75 67 127 •9p 1Aclom 1.270 n 3556 34.77 3 0: 114. 111 0 0 0 0 IIL---_-- 1Actom 1270 . n 3556 34.77 8 - 0 299 - 292. 8 0 299 292 tActom. .1:270 n 35.56 34:77 24 0 853 835 0 - 0 - LL 0 '_ 0 11 U/1 12E-0sw 0.068 a 1.90 1.35 292 249 474 337 0 0 0 0 1Aclom 1.270 a 35.56 91.12 9 0 320 820 0 0 0 0 1Aclom 1.270 a 35.58 91.12 24 0 853 2197 0 0 0 0 Y)/ VE-Ow ' 0.068 s 1.90 1.35 . 489 450 855 608 66 63 - 119 85 LV�--GGD 1Aclom 1Actom ' , 11DO 1.Z70 _ 1:Z70 0.390 s a s - 35.56 35.56 •: 10.92 34:77. 34.77 .11.31 3 15 21 3' 15 "21 ` 114 533 229 111 - 5z2 :MB 3 0 _'0 3 -0 _ 0. 114 0._ 0 111 0 . ,. 0 17N 12E-0sw 0.068 w 1.90 1.35 282 179 342 243 0 0 0 0 FL -CD 1Aclomd 1.270 w 35.56 91.12 82 0 2902 7435 0 0 0 0 11DO 0.390 w 10.92 11.31 21 21 229 238 0 0 0 0 iC ..IM-19md .. 0049, - _ 1,37 3.55 1182 '1182', 1622 .. 4199 -. ..116 -116 -' -.159 _ 412 F 22A tpI 0.989 - 2769 0.00 1182 164 4541 0 116 15 415 0 61 c) AED M=bn 12D5 -115 Envelope loss/gain 15145 19994 1233 876 12 a) Infiltration 2564 702 235 64 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 2 460 0 0 Applianceslother 0 0 Subtotal (lines 6 to 13) 17709 21156 1469 940 Less external load 0 0 0 0 Less transfer 0 0 0 0 Reclistdbution 0 0 0 0 14 Subtotal 17709 21156 1468 940 15 Duct loads 25% 15% 43M 3268 25% 15% 362 145 Total room load 1 =1 24424 1 1830 1 1085 Air required (cirri) 1 1173 1173 97 52 ,&p -Fp' wr1ght50ft' RlghtSu0e91 UnWM1201515.0.02 RSU08101 2015Jun-241 :228:41 ... wm%Quick Calm\Documents\SnNNE7rE,KEVIN.mp CaIc=MJS Fmnt Doorfamv N 9 +-wrightsoft° Right-J® Worksheet Job: Entire House Date: By: QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-46645796 Email: QUIO(CALCS@AOL.COM NEW BATH NEW TM sed wall 19.0 ft 10.0 ft m height F4Rmm 9.4 ft heat/000l 9.4 ft heat/cool dimensions m area 12.0 x 7.0 ft 84.0 ft- 4.0 x 6.0 ft 24.0 fN Ty Construction number U-value (Btuhlft-F) Or HTM (Bh"fL2) Area (ft-) or perimeter (ft) Load (Btuh) Area (ft2) or perimeter (ft) load (Btuh) Heat Cool Gross WP/S Heat Cool Grass N/P/S Heat Cool 6,Vh 12E3sw 0.068 n 1.90 1.35 0 0 -0 0 58 53 101 72 11 F�L--.GGG yl IL a 1Aciom ' 1Ac1am 1Aclom 12E-Osw 1Aclom 1Aclom 1.270 1.270 1.270 MOBS 1.270 1.270 n. n n a a a 35.56 35.56 35.56 1.90 35.56 35.56 34.77 34.77 34.77 1.35 91.12 91.12 0 0 0 113 0 24 0 0 0 89 0 0 - 0 0 0- 169 0 853 0 0 0 120 0 2187 3 0 0 38 0 0 0 0 0 38 0 0 114 0 0 72 0 0 ill 0 0 51 0 0 VVV,,hVV 12E-Osw 0.068 a 1.90 1.35 66 45 85 61 0 0 0 0 1Aclmn 1Ao1om 11D0 1.270 1-270 0.390 s a a 35.58 35.56 10.92. 34.77 34.77 11.31 0 0 21 0 0 21 0 0 229 0 D 238 0 0 0 0 0 01 0 0 0 0 0 0 y/ 12E-Osw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 1Asiomd 1.270 w 35.55 91.12 0 0 0 0 0 0 0 0 LGD 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C 164-19md. 0.049 - 1.37 3.55 84 84 115 2.98 24 24 33 85 F 22A-tpl 0.989 - 27.69 0.00 „ 89 19 526 0 24 10 277 0 6 c) AED ex;ursion -M 39 FJwalope losslgmn 1979 2B14 697 230 12 a) Infiltration 297 81 156 43 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants 230 0 0 0 0 Appliancesfather 0 O Subtotal (lines 6 to 13) 2276 2195 753 323 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2276 2B95 753 323 15 Duct loads 25% 15% 560 447 25% 15% 185 50 Total room load 2936 3342 936 373 Air required (ch) 151 161 50 18 wright5oft' RIghtSuitelD Universal 2015 15.0.02 RSU08101 ... wm\Quick CalmsDoamerdsISTNNETTE,KEVIN.mp Calc=MJB Front Doorfaces N +-wrightsoft° Right-M Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34M Phone: 772-466-6799 Fax 772-4666796 Email: QUICKCALCS@AOL.COM 1 Room name BEDROOM BEDROOM 2 2 Egwsed wall 28.0It 11.0 It 3 Room height 9.4 it Ie&=l 9A 1t heat/cool 4 Room dimensions 16.0 x 13.0 It 10.0 x 11.0 It 5 Room ales 208.0 fP 110.0 iP Ty Construction U-value Or HTM Area (ft2) Load Area OF) Load number (Bh"ftx°F) (BtuhlM or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Coal Gross NIPIS Heat Caol 6 %1�- 12E-Osw 0.06E n 1.90 1.35 122 110 210 149 103 91 174 124 1Aclom 1.270 n 35.56 34.77 0 0 0 0 0 0 0' 0 IAclom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 1A olom 1.270 n - 35.56 34.77 12 0 427 417 12 0 - 427 417 11 V)J 12E-0sw 0.068 a 1.90 1.35 0 0 0 0 0 0 0 0 IAciom 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 L�sCa 1Aclom 1.270 a 35.55 91.12 0 0 0 0 0 0 0 0 w 12E-0sw 0.068 a 1.90 1.35 122 107 204 145 0 0 0 0 �--G IAc1om 1.270 s 35.56 34.77 0 0 0 0 0 0' 0 0 FL----GD IAciam 1.270 s 35.56 34.77 15 15 533 522 0 0 0 0 11DO 0.390 a 10.92 11.31 0 0 0 0 0 01 0 0 V)/ 12E-0sw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 IL 1A,clomd 1.270 w 35.56 91.12 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 -CD' C 164-19md. 0.049 - 1.37 3.55 208 208 285 739 110 110 151 391 F 22A4pl 0.989 - 27.69 0.00 208 26 720 0 110 11 305 0 6 c) AED elcumlon -214 -132 Envelope loWgain 2379 1758 1056 Soo 12 a) Infiltration 407 111 172 47 b) Room ventilation 0 0 1 0 0 13 Internal gains: Occupants @ 230 1 230 1 230 A,pplianooslo/1er 0 0 Subtotal (lines 6 to 13) 2786 2099 171E 1077 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 2786 2099 122E 1077 15 Duct loads 25% 15% 686 324 25% 15% 303 166 Total room load 1 3472 1 2423 1531 1244 Plr required (cfm) 185 116 81 60 -14'WrlightSoft- RlghtSuite® Unlversal 2015 15.0.02 RSLN78101 ... wm\Qulrk Cabs\DommentslSTINNETLE,KEVIN.mp ralc=MJB Fmnt Doorfaces N 2015-Jun-24 10:28:41 Page 3 �+ wrightsoft° Right-M Worksheet Job: Entire House Date: sy. QUICK CALCS, INC. 317 ST. LUGE LN., FT. PIERCE, FL34946 Phone: 772-4666799 Fax 7724666796 Email: QUIQCQ\LCS@ADL.COM Room rerte HALL BATH 2 d wall 0 ft 3.0 ft 3 Room height T1 9.4 ft heat/000l 9.4 ft heat/000l 4 Roem rLmensions 3.0 x 11.0 ft 6.0 x 6.0 ft 5 Room area 33.0 W 38.0 fN Ty Construction U-value Or HTM Area (ft2) Load Area (ft2) Load number (Btuf9ft-F) (BtuhMP) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gnus N/PIS Heat Cool Gross N/P/S Heat Cool 6 W 12E-Osw Q068 n 1.90 1.35" ''0 0 0 0 0 0 0 0 1Aatom. 1.270 n ! 35.55 34.77 0 0- 0 0 0' 0 0 '0 1Aatom 1.270 n- 35.55 34.77 -: '0 0 0 0 0• 0 0 0 tF--CC. 1Actom. 1.270 n 35.56 _34.77 -0 0 _ 0 - 0 ..0 .. .. 0 0 , °. 0 11 Vr 12E-0sw 0.068 a 1.90 1.35 0 0 0 0 28 28 54 38 1Ac1om 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 II--GG 1Ac1om 1.270 a 35.56 91.12 0 0 0 0 0 0 0 0 1M 12E-0sw ' 0.066 s 1.90 1.35 " 0 0. 0 0 0 0 0 0 tAclom' 1270 s 35.56 34.77' 0 0 0. 0 0 0 0 0 I)F-----GGD 1A-ctom 1.270 s 35.56 34.77 10 " _ 0' o 0 0 0 • - 0 0 11D0 0.390 s 10.92 11.31 0' 0, '0' o 0 0, 0 0 YI! 12E-0sw 0.068 w 1.90 1.35 0 0 0 0 0 0 0 0 IL-- ZG tAclomd 1.270 w 35.66 91.12 0 0 0 0 0 0 0 0 11DO 0.390 w 10.92 11.31 0 0 0 0 0 0 0 0 C .� 164-19md _ ''0.049 - - 1.37 .. 3.55 33 .: `33' 45 117 - ,36' 36 49 r 128 F 22A-td - .0.989 - 27.E 0.00 33 . 0 0 0 36 3 83 0 61 c) AED excursion -13 -19 Envelope loss(gain 45 104 186 147 12 a) Infiltration 0 0 47 13 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 23D 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13) 45 104 233 159 Less e#emal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 45 104 233 159 15 Duct loads 25% 15% 11 16 25% 15% 57 25 Total room load 56 121 290 184 Air requrired (cfm) 3 6 15 9 MCA -94- wrightsoft- RlghtSufte® Universal 2015 15.0.02 RSL*8101 M: ff�W2015=;fun-241 : 9e 4 ... ses\Qufck Calcsll7ommems\STINNETTE,KEVIN.mp Calc=MJB Front Doorfaces: N wrightsoft Right-J® Worksheet Job: Entire House Date: ey. QUICK CALCS, INC. 317 ST. LUCIE LN., FT. PIERCE, FL34946 Phone: 772-466-6799 Fax 772-466-6796 Final]: QUIOCCALCS@AOL.COM 1 Room mme KITCHEN LIVING ROOM 2 Fposed Nall 22.0 It 58.0 ft 3 Room height 9.4 ft heaticool 9.4 ft heat/cool 4 5 Room dimensions Room area 1.0 x 151.0 ft 151.0 ft' 30.0 x 14.0 It 420.0 fe Ty Consbuction Llvalue Or HTM Area (ft) Load Anew (ft2) Load number (Btuh/ft-F) (B[L"M or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross NIPIS Heat Cool Gross NIPIS Heat Cool 12E-0sw 0.069 n 1.90 1.35 0 0 0 0 132 132 251 178 I--G IAoIom 1,270 n 35.56 34.77 0 0 0 0 0 0 0 0 IAolom 1.270 n 35.56 34.77 0 0 0 0 0 0 0 0 11 I�--,--GG It L�CG tAclom 12E-0sw 1Aciom 1Aclom 12E-0gw 1.270 0.068 1.270 1.270 0.068 n a a a s 35.56 1.90 35.56 35.56 1.90 34.77' 1.35 91.12 91.12 1.35 0 103 9 0 103 0 94 0 0 103 0 180 320 0 197 0 128 820 0 140 0 0 0 0 132 0- 0 0 0 132: 0 0 0 0 251 0 0 0 0 178 V)/ I)�------GGD 1"lom 1Aciorn 11DO 12E-0sw 1.270 1.270 0.390 0.068 s s a. w 35.58 35.55 10.92 1.9D 34.77 34.77 _11.31 1.35 0 0 0 0 0 0 0 0 0. - 0 , 0 0 0 0 0 0 0 0 0 2B2 0 0 0 179 0 0 0 342 0 0 0 243 W, �LGD 1Aclomd 1.270 w 35.56 91.12 0 0 0 0 82 0 2902 7435 11DO 0.390 w 10.92 11.31 0 0 0 0 21 21 229 238 C 16A-19md. , 0.049 - 1.37 3.55 151 151 207 536 420 420 576 1492 F 22A-tp( 0.989 - 27.69 0.00 151 22 609 0 42D 58 1606 0 61 c) AED mureon -99 1926 Erwelope losstgain 1513 1625 6156 11690 12 a) Infiltration 344 94 9(Y7 248 b) Room ventilation 0 0 0 0 13 Intemal gaits: Occupants ® 230 0 0 0 0 Aypliarnceslother 0 0 Subtotal (Airs 6 to 13) 1857 1619 7063 11938 Less mdemal load 0 0 0 0 Less trarsfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1857 1619 7063 11938 15 Duct loads 25% 15% 457 250 25% 15% 1740 1844 Total room load 1 2314 1 18M 8803 13782 Air required (chn) 123 90 468 662 -F}t wrightsoft- RightSuite® UnNeml 201515.0.02 RSU08101 �� ... ears\Quick Catm\Domments%STINNETTE, KEVIN.mp Calc=MJS Front Doorfamv N TLT. NEW BATH NEW OFFICE 14fg)cq 'ITT IIaICFr+� It.¢Ciw- N aoQU LMA NOY $ Job #: Performed for. MR & MRS KEVIN STINNETTE 10303 S.INDIAN RIVER DRIVE FT. PIERCE, FL lLtY4 $x-tYyRAft KITCHEN Obcci�;01 tuxlvl LIVING ROOM QUICK CALCS, INC. 317 ST. LUCIE UN. FT. PIERCE, FL34946 Phone:772-166-6799 Fax:772-466-6796 QUICKCALCS@AOL.COM R