HomeMy WebLinkAboutPRODUCT APPROVALFILE'CP,
6Q5 Home I lag In I user Registration I Mot Topla I submit surcharge
'I Product Approval
USER: public user
rem rir
r :. .:
Suits a raar I Publications contact Us I BOS site Map Units I Saa c
RECEIVED
R i o )nlo
Orndue 699r 1 Menu > Product or Apelfcalf,r, Stoo,lb>
Amllcatlon List > Application Detail
rn'
FL a
FL17022-R7
ST. Lucie County, Permitting
Application Type
Revision
Code Version
2017
Application Status
Approved
-SCANNED
BY
Comments
Archived
08/18/2017v. date reapply 08/21/17
❑ St. Lucie County
Product Manufacturer
Extreme Metal Fabricators, LLC
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
flvalidation@yahoo.com
Authorized Signature
Richard McKuhen
0validation@yahoo.com
Technical Representative
Richard McKuhen
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
O Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr odf
Referenced Standard and Year (of Standard) Standard year
TAS 125 2003
UL1897 2012
UL 580 2006
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FL # j%kodell,
N_ umber or Name
Description
17022.1
' (
26 Gauge steel, 3/8" rib height, 24' wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits of Use f.
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 II FL 17022.1 5 V CRIMP ssr odf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports '
Other: Refer to evaluation report for conditions. Install the
assembly in compliance with the installation method listed in
FL17022 R7 A FIL 17022.1 5 V CRIMP ssr.odf
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's Installation instructions.
17022.2
2 - "5V Crimp" (R6)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.2 5 V CRIMP 0.032M ssrndf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes -
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions.Install the
FL17022 R7 AE FL 17022.2 5 V CRIMP 0.032
assembly in compliance with the installation method listed in
ALUM ssrodf
this report and applicable code sections of FBC. Refer to
Created by Independent Third Party: Yes
manufacturer's Installation instructions.
17022.3
r3l.5" Mechanical Seam' (115)
1.5" rib height, 16' wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with dips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL37022 R7 II FL 17022.3 1.5 MECHANICAL
Approved for use outside HVHZ: Yes
Impact Resistant: No
seam 24oa ssr odf
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022,3 1,5 MECHANICAL
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
seam 24oa ssr.odf
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (115)
1.5" rib height, 16' wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15132" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 II FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
ALUMINUM ssrodf
the Installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's Installation
Created by Independent Third Party: Yes
Instructions.
17022.5
5 - "I in. Nail Strip' (RS)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
'
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL17022 R7 11 F 17022.5 1.0 NAI STRIP s r odf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
EL17022 R7 AE FL 17022,5 1.0 NAI STRIP ssrpdf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.E
6 - "1 in. Nail Strip" (RS)
1" rib height, 16' wide, 0.032" aluminum, standing seam
roof panel mechanically attached to attached to 15/32"
plywood or Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 11 FL 17022.6 1 .0 NAIL STRIP 0,032
ALUM s r odf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for Conditions and
Evaluation Reports
limitations of use. Install the assembly in Compliance with
FLIZO22 R7 17022.6 TR P 0,032
ALUM ssr.odf
the Installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Created by Indepentlent Third Party: Yes
instructions.
17022.7
7 - "1.5 in. Nail Strip" (RS)
1.5" rib height, 19' wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/321 plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL1702 7 2Strip
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly in Compliance with
FL17022 R7 AE FL 17022.7 1.5 Nail Strip 26GA ssr odf
Created by Indepentlent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
Approved for use outside HVHZ: Yes
FL12022 R7 it FL 177022.8 EMAX Rib ssr.odf
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr.odf
limitations of use. Install the assembly in compliance with
Created by Independent Third Party: Yes
the Installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
instructions.
17022.9
9 - n PBR MAX" (RS)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL17022 R7 IT FL 17022.9 PBR RIB sscodf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
limitations of use. Install the assembly In Compliance with
FL17022 R7 AE FL 17022.9 PBR RIB ssr odf
Created by Independent Third Party: Yes
the installation method listed in this report and applicable
code sections of FBC. Refer to manufacturer's installation
Instructions.
Coated Us:: 2601 Blair Stone Road, Tallahassee R 323" Phone: 850487-1824
The state of Muds Is an An,b employer. CaovdaM1[ TOOT-20f3 Stte of Flodtla :: Pmacv statement :: Aotessibil" Statement :: Refund Statement
Under Florida law, email addresses are public remrds. If you do not want your e-mall address released in response to a public -records request, do not sand electronic
mall to Mls empty. Inslead, avntad the of8m by phone or by traditional mall. If you have any questions, please cooled 650.487.1395. *Pursuant to Section
455.275(1), Flodtla Statutes, effiedi m October 1, 2012, limnseas licensed under Chapter 455, F.S. must provide the Department with an email atldress If May have
one. The emails provided may be used for oificlal communication win Me limn¢¢. However ¢mall addresses are public record. if you do not wish to supply a
personal address, please povide Me Department with an email address whidm Con he made avallable M the pubhn To determine if you am a licensee under Chapter
Product Approval Astatine:
.�® 5-W
"secmity""rmc�r
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec. 1507.4.3
Fastener 1 (Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD i
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF
-93.5 PSF
-101 PSF
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6" o.c.
FASTENER SPACING (ALONG Panel width)
12" o.c.
12" o.c.
12" ox.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report D35893.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to teststandard UL 1897-1?fl 1 r� r *Design pressure margin of safety 2:1
Locke Bowden, P.E. does not have, not will acquire a financial intqo-'4iq ar��cgq(r m�iWfacturing or distributing products
L .'i. i�
under this evaluation. �. . " Z
Locke Bowden, P.E. is not owned, operated, or controlled by apy cosnparNDrn46afaLtures, or Clstributing products under this
p
re ort. 6
STATE OF /31l/ %
tofflv
FL17022.1 5V . limp (26GA Steel), 24" Wide Roof ". iel -Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6'^ ed.
2. Minimum slope to be compliant with Florida Building Code 2017 61" ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6lh ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
— Fasteners -
#9 - 1-11T Min. or
#10"1-1/2"Min. per Tatde"ilw for Row SSV crimp Roof Panel
Spacing and Design Pressures
Hex Washer Head Wood Sams
Deck:
-1 S32" orgreater PW,00d, or
- Wood plank
24"
T
3t�
T
Panel Profile
Nominall2" _ Nominall2"
O.C. o.c.
Fasten
9 x 1-1/2" Min. or #10 x 1-1/2" Min. per
lable'A" Hex Washer Head Screw
Spaced 12" o.c. across the Panel Width
Panel
Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck- 15/32" or greater
Plywood, or
-VWod plank
BM Home I log In I User Registration I
Hat Topits I submit Sumhmge Stats RF.M I publications
Contact Us I 8C1SSite Ma Unk 1 5
�" Product Approval
®
SCANNEI]
BY
RECEIVED
P
USER: Public Use
St. Lucie County
APR 12 2019
Pmdurt Aoomval Menu > EMduCt or Appiri,,tiOn>
AnollcatlRn Ust> Appliwtlon Detail
ST. Lucie County, Pern
FL tk
FL16048-R6
Application Type
Revision
Code Version
2017
Application Status
Approved
Comments
Archived
❑
Product Manufacturer
Tri-Built Materials Group, LLC
Address/Phone/Email
PO Box 70
Rutherford, NJ 07070
(800) 516-1485
dav[d.miz@bribujltmg.com
Authorized Signature David Ruiz
david.ruiz@tribulltmg.com
Technical Representative David Ruiz
Address/Phone/Email 250 Route 17 North
East Rutherford, NJ 07073
(201)842-2449
david.ruiz@tribuiltmaterialsgroup.com
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Underlayments
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed
Florida Professional Engineer
❑ Evaluation Report- Hardcopy Received
Florida Engineer or Architect Name who developed Robert Nieminen
the Evaluation Report
Florida License PE-59166
Quality Assurance Entity UL LLC
Quality Assurance Contract Expiration Date 07118/2020
Validated By John W. Knezevich, PE
21 Validation Checklist - Hardcopy Received
Certificate of Independence FL16048 R6 COI 2017 01 COI Nieminen.odf
Referenced Standard and Year (of Standard) Standard year
ASTM D1970
2015
ASTM G155
2005
FM 4474
2011
FRSA/TRI April 2012 (04-12)
2012
UL 1897
2012
Equivalence of Product Standards
Certified By
Sections from the Code
Product Approval Method Method 1 Option D
Date Submitted 09/25/2017
Date Validated 10/01/2017
Date Pending FBC Approval 10/03/2017
Date Approved 12/12/2017
Summary of Products
r—�
FL*
Model, Number or Name
Description
16048.1
TRI-BUILT Roof Underlayments
Self -adhering, modified bitumen roof underlayments
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
FL16048 R6 fl 2017 09 FINAL ER TRI-
Approved for use outside HVHZ: Yes
BUILT ND R AYM NT F 16048-R6 odf
Impact Resistant: N/A
Verified By: Robert Nleminen PE-59166
Design pressure: +N/A(-150
Created by Independent Third Party: Yes
Other: 1.) The design pressure noted herein pertains to use
Evaluation Reports
of foam -On the systems overtop the Self -adhering
FL16048 R6 AE 2017 09 FINAL ER TRI-
underlayment for one particular application. See ER Section
BUILT ND R AYM NT F 16048-R6.odf
5.6.4 for details. 2.) Refer to ER Section 5 for other Limits of
Created by Independent Third Party: Yes
Use.
�r13:: 2601 Blair Stone Read, Tallabassee R 3Z2i99 Phan: 850487-1824
The State of Fermin la an AA/EEO employer. CoovdaM1t 20W-2013 State of Fbrida.:: Privacy Statement :: A¢eesibilid Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mail address released in moonrise to a public -records request, do not send electronic
mall to this entity. Instead, confect the office by phone or by traditlonal mail. If you have any questions, please contact 850.487.1395. *Pumsuant to Section
455.275(1), Florida Statutes, effective October 1, 2012, license¢ licensed under chapter 455, F.S. must provide the Department with an email addmass If Nay have
one. The totals provided may b i acted for official communication with the licensee. liewever email addms m are public rewrtl. If you do not wish to supply a
personal address, please provide the Department with an email address which can be made aualLible to the public To determine it you are a beer¢¢ under chapter
455, F.S., please click here .
product Approval Accepts:
F.F9991lovi 1 99 0
sectlrityAl&rRlcs