Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODERFCFtVFO COPY FORM R405-2017 Per qPR I2 ZO14 I LE mrtt FLORIDA ENERGY EFFICIENCY CODE F�fik#UJDING CONSTRUCTION o� , ent ?. 'Florida Department of Business and Professional Regulation - k2 os" dential Performance Method Project Name: MW-208 Builder Name: GHO HOMES SCANNED Street: 2702 BENT PINE DR Permit Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, 34951 Owner: t) Permit Number: Jurisdiction: St. LUCIE cotjnt / Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types(2411.4 sqft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.0 2118.90 ft' b. Frame - Wood, Adjacent R=11.0 292.44 ft2 3. Number of units, if multiple family 1 c. N/A R= ft 4. Number of Bedrooms 3 d. N/A R= ft2 5. Is this a worst case? No 10. Ceiling Types (2521.0 sqft.) Insulation Area a. Under Attic (Vented) R=40.0 2521.00 ft2 6. Conditioned Floor area above grade (ft2) 2521 b. N/A R= ft' Conditioned floor area below grade (111:2) 0 c. N/A R= ft2 11. Ducts R ft 7. Windows(464.5 sqft.) Description Area a. Sup: Attic, Ret: Attic, AH: Main 6 814 a. U-Factor: Dbl, U=0.62 464.51 ft2 SHGC: SHGC=0.26 " b. U-Factor. N/A ft2 12. Cooling systems kBtu/hr Efficiency SHGC: a. Central Unit 60.0 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor: N/A ft2 a. Electric Strip Heat 34.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 0.000 ft. Area Weighted Average SHGC: 0.260 14. Hot water systems a. Electric Cap: 50 gallons 8. Floor Types (2521.0 sqft.) Insulation Area EF: 0.940 a. Slab -On -Grade Edge Insulation R=0.0 2521.00 ft' b. Conservation features b. N/A R= ft2 None c. N/A R= ft2 15. Credits Pstat Total Proposed Modified Loads: 80.37 Glass/Floor Area: 0.184 PASS Total Baseline Loads: 80.92 I hereby certify that t plans and specifications covered by Review of the plans and STgle this calculation are in c plian a with the lorida Energy specifications covered by this OF4Hfi Code. calculation indicates compliance f. '•••; �rt�'•`.:°'��o with the Florida Energy Code. nn O PREPARED BY: Before construction is completed C DATE: \1 N 3/7-11/17 this building will be inspected for compliance with Section 553.908 e n I hereby certify that this building, s designed, is in compliance Florida Statutes. I,U with the Florida Energy Code. OWNERIAG T: BUILDING OFFICIAL: C0 yV8't'�� DATE:Cl DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). 3/28/2019 8:14 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Building Type: Owner Name: # of Units: Builder Name: Permit Office: Jurisdiction: Family Type: New/Existing: Comment: MW-208 User 1 GHO HOMES ST LUCIE COUNTY Single-family New (From Plans) Bedrooms: 3 Conditioned Area: 2521 Total Stories: 1 Worst Case: No Rotate Angle: 0 Cross Ventilation: No Whole House Fan: No Address Type: Street Address Lot # Block/Subdivision: PlatBook: Street: 2702 BENT PINE DR County: St. Lucie City, Stale, Zip: FORT PIERCE, FL, 34951 CLIMATE V Design Location Design Temp TMY Site 97.5 % 2.5 % Int Design Temp Heating Design Daily Temp Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Blockl 2521 23445.3 SPACES Number Name Area Volume Kitchen Occupants Bedrooms InfI ID Finished Cooled Heated 1 Main 2521 23445.3 Yes 4 3 1 Yes Yes Yes FLOORS # Floor Type Space Perimeter R-Value Area Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Main 213.7 It 0 2521 ft2 ___ 0 0 1 ROOF / V # Type Roof Gable Roof Materials Area Area Color Solar Absor. SA Emitt Emil Deck Pilch Tested Tested Insul. (deg) 1 Hip Flat tile/slate 2819 ft2 0 ft2 Medium 0.4 N 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 in) Area RBS IRCC 1 Full attic Vented 150 2521 ft- N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Main 40 Blown 2521 ft2 0.1 Wood 3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT WALLS Adjacent Cavity Width Height Sheathing Framing Solar Belo Space w _ 1 N Exterior Concrete Block - Ed Insul Main 4 64 10 9 4 605.1 ft- 0 0 0.3 0 -2 E Exterior Concrete Block - Ext Insul Main 4 55 0 9 4 513.3 ft- 0 0 0.3 0 -3 BE Exterior Concrete Block - Ext Insul Main 4 3 1 9 4 28.8 ft2 0 0 0.3 0 -4 S Exterior Concrete Block - Ext Insul Main 4 35 11 9 4 335.2 ft2 0 0 0.3 0 -5 SW Exterior Concrete Block - Ext Insul Main 4 3 1 11 4 34.9 W 0 0 -0.3 0 -6 W Exterior Concrete Block- Ext Insul Main 4 62 10 9 4 586.4 ft2 0 0 0.3 0 _ 7 NW Exterior Concrete Block - Ext Insul Main 4 1 4 11 4 15.1 ft2 0 0 0.3 0 8 - Garage Frame - Wood Main 11 31 4 9 4 292.4 11:2 0 0.25 0.3 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 S Wood Main None .39 6 8 48 ft2 WINDOWS Orientation shown is the entered, Proposed orientation. J Wall Overhang # Ornt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Inl Shade Screening _ 1 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft- 0 It 0 in 0 It 0 in None None 2 n 1 Metal Double (Clear) Yes 0.62 0.26 N 20.0 W 0 ft 0 in 0 ft 0 in None None 3 n 1 Metal Double (Clear) Yes 0.62 0.26 N 43.8 f12 0 ft 0 in 0 ft 0 in None None 4 n 1 Metal Double (Clear) Yes 0.62 0.26 N 111.6 ft2 0 ft 0 in 0 ft 0 in None None 5 e 2 Metal Double (Clear) Yes 0.62 0.26 N 22.0 ft2 0 ft 0 in 0 ft 0 in None None 6 e 2 Metal Double (Clear) Yes 0.62 0.26 N 14.0 ft- 0 ft 0 in 0 ft 0 in None None 7 e 2 Metal Double (Clear) Yes 0.62 0.26 N 43.3 ft2 0 ft 0 in 0 ft 0 in None None 8 as 3 Metal Double (Clear) Yes 0.62 0.26 N 14.0 ft2 0 It 0 in 0 It 0 in None _ None 9 s 4 Metal Double (Clear) Yes 0.62 0.26 N 21.7 ft2 0'ft 0 in 0 ft 0 in None None 10 s 4 Metal Double (Clear) Yes 0.62 0.26 N 24.0 ft2 0 ft 0 in 0 ft 0 in None None 11 s 4 Metal Double (Clear) Yes 0.62 0.26 N 42.0 ft2 0 R 0 in 0 It 0 in None None 12 sw 5 Metal Double (Clear) Yes 0.62 0.26 N 14.0 ft2 0 ft 0 in 0 ft 0 in None None 13 w 6 Metal Double (Clear) Yes 0.62 0.26 N 7.0 ft2 0 ft 0 in 0 ft 0 in None None 14 w 6 Metal Double (Clear) Yes 0.62 0.26 N 12.0 ft2 0 ft 0 in 0 ft 0 in None None 15 W 6 Metal Double (Clear) Yes 0.62 0.26 N 31.8 ft2 0 ft 0 in 0 ft 0 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 1106 ft2 1106 ft2 64 ft 9.3 ft 1 3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT INFILTRATION # Scope Method SLA CFM 50 ELA EgLA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000414 2735.3 150.16 282.4 .3136 7 HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COPA 34 kBtu/hr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Unit/ Split SEER: 16 60 kBtu/hr 1800 cfm 0.7 1 sys#1 HOT WATER SYSTEM # System Type SubTpe Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.94 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Cart # Company Name Collector Storage System Model # Collector Model # Area Volume FEF None None ft' DUCTS / —Supply— V # Location R-Value Area —Return— Air CFM 25 CFM25 Location Area Leakage Type Handler TOT OUT QN RLF HVAC# Heat Cool 1 Attic 6 814 fF Attic 657 ft- Default Leakage Main (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Feb Mr Venting Jan Feb Mar Crreiling Fans: [X� jX� jXj [ ] Oct Nov Apr [ May May Jun [ ] Jul E ] Aug [ ] Sep L J Oct Nov Jun [ 1 Jul )Aug L 1 Sep lxJ Dee Dec 3128/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM fib 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 MASS Mass Type Area Thickness Furniture Fraction Space Default 8 Ibs/s .ft. 0 ft' 0 ft 0.3 Main Name: Signature: Rating Compant: Date: 3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 99 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity60.0 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2521 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.620 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.260 14. Heating system: Capacity 34.0 c) Area 7c. 464.5 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.94 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.0 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 40.0 b) Cross ventilation No b) Single assembly 11b. c) Whole house fan No c) Knee walls/skylight walls 11 C. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit f) Programmable thermostat Yes 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has complied kith the Florida Building Code, Energy Conservation, through the above energy saving features which will be installe (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be completed base on installed code compliant features. Builder Signature: Date: /2II �( Address of New Home: City/FL Zip: FORT PIERCE, FL 34951 3/28/2019 8:14:13 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -+ wrightsoftLoad Short Form Entire House For: MW-208 2704 BENT PINE DR, FORT PIERCE, FL 34951 Job: Date: Mar 11, 2019 By: Htg Clg Infiltration Outside db (°F) 43 91 Method Simplified Inside db (°F) 70 72 Construction quality Semi -tight Design TO (°F) 27 19 Fireplaces 0 Daily range - L Inside humidity (%) 30 50 Moisture difference (gr/Ib) 0 65 HEATING EQUIPMENT Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 10.1 kW 34434 Btuh 17 °F 1833 cfm 0.054 cfm/Btuh 0 in H2O COOLING EQUIPMENT Make Carrier Trade 16 SEER PURON AC Cond CA16NA060""A Coil FV4CNB006 AHRI ref 4585445 Efficiency 14.0 EER, 16 SEER Sensible cooling 38500 Btuh Latent cooling 16500 Btuh Total cooling 55000 Btuh Actual air flow 1833 cfm Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Load sensible heat ratio 0.71 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) MASTER SUITE 333 6215 5890 333 280 HIS WIC 53 894 442 48 21 MASTER BATH 159 1685 2347 90 112 HER WIC 74 76 237 4 11 DEN 199 3886 3091 208 147 FOYER 86 1839 1729 99 82 DINING 161 2726 2751 146 131 MECH 38 486 718 26 '34 UTILITY 53 77 736 4 35 BATH 2 58 1007 963 54 46 BED 2 180 1887 2838 101 135 BED 3 178 1932 2854 104 136 BATH 3 58 1673 1179 90 56 REAR VEST 50 1197 1013 64 48 NOOK 99 3670 4423 197 210 ✓lr Uu Ki Onn nne .IGCI 4O on Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Mar-13 12:14:04 ,y wrightwft' RlghtSuite® Universai201212.1.05 RSU02818 Pagel X& CAUsersUasonTocuments\Wrightsoft HVACWW-208.rup Cale =MJ8 Front Door faces: S VMmmI RIVI UTILITY HALL 41421 95 4411 319 D-1`Jl 293 Z6/ 17 441 14 Entire House 2523 34216 38563 1833 1833 'Other equip loads 0 0 Equip. @ 0.95 RSM 36828 Latent cooling 15543 Tl1TA1 C I ncnn I nen.lc .loon I .loon V I/l�V LJGJ JYLIV JLJ,V IVJJ IVJJ Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2019-Mar-13 12:14:04 �- wrightsOft RlghtSulte® Universal 201212.1.05 RSU02818 Paget �+� C:\UsersUasonlDocuments\Wrightsoft HVACWW-208.Iup Cato =MJ8 Front Door faces: S +b- wrightsoft* Project Summary Entire House For: MW-208 2704 BENT PINE DR, FORT PIERCE, FL 34951 Notes: Design Information Weather: Vero Beach Municipal AP, FL, US Job: Date: Mar 11, 2019 By: Winter Design Conditions Summer Design Conditions Outside db 43 OF Outside db 91 OF Inside db 70 OF Inside db 72 OF Design TD 27 OF Design TD 19 OF Daily range L Relative humidity 50 % Moisture difference 65 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 28707 Btuh Structure 28760 Btuh Ducts 5509 Btuh Ducts 9803 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 34216 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Infiltration Equipment sensible load 36828 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -tight Fireplaces 0 Structure 12871 Btuh Ducts 2672 Btuh Heating Cooling Central vent (0 cfm) 0 Btuh Area (ft2) 2523 2523 Equipment latent load 15543 Btuh Volume (ffa) 25539 25539 Air changes/hour 0.22 0.11 Equipment total load 52370 Btuh Equiv. AVF (cfm) 94 47 Req. total Capacity at 0.70 SHR 4.4 ton Heating Equipment Summary Cooling Equipment Summary Make Make Carrier Trade Trade 16 SEER PURON AC Model Cond CA16NA060****A AHRI ref Coil FV4CNB006 AHRI ref 4585445 Efficiency 100 EFF Efficiency 14.0 EER, 16 SEER Heating Input 10.1 kW Sensible cooling 38500 Btuh Heating output 34434 Btuh Latent cooling 16500 Btuh Temperature rise 17 OF Total cooling 55000 Btuh Actual air flow 1833 cfm Actual air flow 1833 cfm Air flow factor 0.054 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 0 in H2O Static pressure 0 in H2O Space thermostat Load sensible heat ratio 0.71 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. WI't Il$SOi3' 2019-Mar-1312:14:04 g RlghtSuile® Universal 2012 12.1.05 RSU02818 Page 1 C:1UsemVasonlDocuments%Wrightsoft HVACWW-208.rup Cale =MJ8 Front Door faces: S HOMES 2702 BENT FINE DR FORT FIERCE, FL 34951