HomeMy WebLinkAboutENERGY EFFICIENCY CODERFCFtVFO COPY
FORM R405-2017 Per qPR I2 ZO14 I LE
mrtt
FLORIDA ENERGY EFFICIENCY CODE F�fik#UJDING CONSTRUCTION
o� , ent
?. 'Florida Department of Business and Professional Regulation - k2 os" dential Performance Method
Project Name: MW-208
Builder Name: GHO HOMES
SCANNED
Street: 2702 BENT PINE DR
Permit Office: ST LUCIE COUNTY
BY
City, State, Zip: FORT PIERCE, FL, 34951
Owner: t)
Permit Number:
Jurisdiction:
St. LUCIE cotjnt /
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types(2411.4 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.0 2118.90 ft'
b. Frame - Wood, Adjacent
R=11.0 292.44 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft
4. Number of Bedrooms 3
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (2521.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=40.0 2521.00 ft2
6. Conditioned Floor area above grade (ft2) 2521
b. N/A
R= ft'
Conditioned floor area below grade (111:2) 0
c. N/A
R= ft2
11. Ducts
R ft
7. Windows(464.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: Main
6 814
a. U-Factor: Dbl, U=0.62 464.51 ft2
SHGC: SHGC=0.26
"
b. U-Factor. N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
60.0 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
34.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 0.000 ft.
Area Weighted Average SHGC: 0.260
14. Hot water systems
a. Electric
Cap: 50 gallons
8. Floor Types (2521.0 sqft.) Insulation Area
EF: 0.940
a. Slab -On -Grade Edge Insulation R=0.0 2521.00 ft'
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat
Total Proposed Modified Loads: 80.37
Glass/Floor Area: 0.184
PASS
Total Baseline Loads: 80.92
I hereby certify that t plans and specifications covered by
Review of the plans and
STgle
this calculation are in c plian a with the lorida Energy
specifications covered by this
OF4Hfi
Code.
calculation indicates compliance
f. '•••; �rt�'•`.:°'��o
with the Florida Energy Code.
nn O
PREPARED BY:
Before construction is completed
C
DATE: \1 N 3/7-11/17
this building will be inspected for
compliance with Section 553.908
e n
I hereby certify that this building, s designed, is in compliance
Florida Statutes.
I,U
with the Florida Energy Code.
OWNERIAG T:
BUILDING OFFICIAL:
C0 yV8't'��
DATE:Cl
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2).
3/28/2019 8:14 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
MW-208
User
1
GHO HOMES
ST LUCIE COUNTY
Single-family
New (From Plans)
Bedrooms: 3
Conditioned Area: 2521
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation: No
Whole House Fan: No
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 2702 BENT PINE DR
County: St. Lucie
City, Stale, Zip: FORT PIERCE,
FL, 34951
CLIMATE
V Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90
70
75 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
2521 23445.3
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
InfI ID Finished Cooled Heated
1
Main
2521 23445.3 Yes 4
3
1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area
Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 213.7 It 0
2521 ft2
___ 0 0 1
ROOF
/
V #
Type
Roof Gable Roof
Materials Area Area Color
Solar
Absor.
SA Emitt Emil Deck Pilch
Tested Tested Insul. (deg)
1
Hip
Flat tile/slate 2819 ft2 0 ft2 Medium
0.4
N 0.9 No 0 26.6
ATTIC
/
V #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 2521 ft-
N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Frac Truss Type
1
Under Attic (Vented)
Main 40 Blown
2521 ft2 0.1 Wood
3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width
Height
Sheathing Framing Solar
Belo
Space
w
_ 1
N
Exterior
Concrete Block - Ed Insul
Main
4 64
10 9
4
605.1 ft-
0
0
0.3
0
-2
E
Exterior
Concrete Block - Ext Insul
Main
4 55
0 9
4
513.3 ft-
0
0
0.3
0
-3
BE
Exterior
Concrete Block - Ext Insul
Main
4 3
1 9
4
28.8 ft2
0
0
0.3
0
-4
S
Exterior
Concrete Block - Ext Insul
Main
4 35
11 9
4
335.2 ft2
0
0
0.3
0
-5
SW
Exterior
Concrete Block - Ext Insul
Main
4 3
1 11
4
34.9 W
0
0 -0.3
0
-6
W
Exterior
Concrete Block- Ext Insul
Main
4 62
10 9
4
586.4 ft2
0
0
0.3
0
_ 7
NW
Exterior
Concrete Block - Ext Insul
Main
4 1
4 11
4
15.1 ft2
0
0
0.3
0
8
-
Garage
Frame - Wood
Main
11 31
4 9
4
292.4 11:2
0
0.25
0.3
0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
S
Wood Main
None
.39
6
8
48 ft2
WINDOWS
Orientation shown is the entered, Proposed orientation.
J
Wall
Overhang
#
Ornt ID
Frame
Panes NFRC
U-Factor SHGC
Imp
Area
Depth
Separation
Inl Shade
Screening
_
1
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 ft-
0 It 0 in
0 It 0 in
None
None
2
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
20.0 W
0 ft 0 in
0 ft 0 in
None
None
3
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
43.8 f12
0 ft 0 in
0 ft 0 in
None
None
4
n 1
Metal
Double (Clear)
Yes
0.62 0.26
N
111.6 ft2
0 ft 0 in
0 ft 0 in
None
None
5
e 2
Metal
Double (Clear)
Yes
0.62 0.26
N
22.0 ft2
0 ft 0 in
0 ft 0 in
None
None
6
e 2
Metal
Double (Clear)
Yes
0.62 0.26
N
14.0 ft-
0 ft 0 in
0 ft 0 in
None
None
7
e 2
Metal
Double (Clear)
Yes
0.62 0.26
N
43.3 ft2
0 ft 0 in
0 ft 0 in
None
None
8
as 3
Metal
Double (Clear)
Yes
0.62 0.26
N
14.0 ft2
0 It 0 in
0 It 0 in
None
_
None
9
s 4
Metal
Double (Clear)
Yes
0.62 0.26
N
21.7 ft2
0'ft 0 in
0 ft 0 in
None
None
10
s 4
Metal
Double (Clear)
Yes
0.62 0.26
N
24.0 ft2
0 ft 0 in
0 ft 0 in
None
None
11
s 4
Metal
Double (Clear)
Yes
0.62 0.26
N
42.0 ft2
0 R 0 in
0 It 0 in
None
None
12
sw 5
Metal
Double (Clear)
Yes
0.62 0.26
N
14.0 ft2
0 ft 0 in
0 ft 0 in
None
None
13
w 6
Metal
Double (Clear)
Yes
0.62 0.26
N
7.0 ft2
0 ft 0 in
0 ft 0 in
None
None
14
w 6
Metal
Double (Clear)
Yes
0.62 0.26
N
12.0 ft2
0 ft 0 in
0 ft 0 in
None
None
15
W 6
Metal
Double (Clear)
Yes
0.62 0.26
N
31.8 ft2
0 ft 0 in
0 ft 0 in
None
None
GARAGE
#
Floor Area
Ceiling Area
Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
1106 ft2
1106 ft2
64 ft
9.3 ft
1
3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
INFILTRATION
# Scope Method
SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50)
.000414
2735.3 150.16 282.4 .3136 7
HEATING SYSTEM
# System Type
Subtype
Efficiency Capacity Block
Ducts
1 Electric Strip Heat/
None
COPA 34 kBtu/hr 1
sys#1
COOLING SYSTEM
# System Type
Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1 Central Unit/
Split
SEER: 16 60 kBtu/hr 1800 cfm 0.7 1
sys#1
HOT WATER SYSTEM
# System Type SubTpe
Location
EF Cap Use SetPnt Conservation
1 Electric None
Garage
0.94 50 gal 62.3 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cart # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
/ —Supply—
V # Location R-Value Area
—Return— Air CFM 25 CFM25
Location Area Leakage Type Handler TOT OUT QN RLF
HVAC#
Heat Cool
1 Attic 6 814 fF
Attic
657 ft- Default Leakage Main (Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y Feb Mr
Venting Jan Feb
Mar
Crreiling Fans: [X� jX� jXj [ ] Oct Nov
Apr [ May May Jun [ ] Jul E ] Aug [ ] Sep L J Oct Nov
Jun [ 1 Jul )Aug L 1 Sep lxJ
Dee
Dec
3128/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
fib
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default 8 Ibs/s
.ft.
0 ft'
0 ft
0.3
Main
Name: Signature:
Rating Compant: Date:
3/28/2019 8:14 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 5
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 99
The lower the Energy Performance Index, the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R 6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R 6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3. 1
4. Number of bedrooms
4. 3
13. Cooling system: Capacity60.0
a) Split system SEER 16.0
5. Is this a worst case? (yes/no)
5. No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6. 2521
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a. 0.620
b) Solar Heat Gain Coefficient (SHGC)
7b. 0.260
14. Heating system: Capacity 34.0
c) Area
7c. 464.5
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP 1.0
a) U-factor:(weighted average)
8a. NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b. NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a. 0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF 0.94
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2. 4.0
f) Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1. 11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a. 40.0
b) Cross ventilation No
b) Single assembly
11b.
c) Whole house fan No
c) Knee walls/skylight walls
11 C.
d) Multizone cooling credit
d) Radiant barrier installed
11d. No
e) Multizone heating credit
f) Programmable thermostat Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied kith the
Florida Building Code, Energy Conservation, through the above energy
saving features which will be installe (or exceeded) in this home before
final inspection. Otherwise, a new EPL
display card will be completed base on installed code compliant features.
Builder Signature:
Date: /2II �(
Address of New Home:
City/FL Zip: FORT PIERCE, FL 34951
3/28/2019 8:14:13 PM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-+ wrightsoftLoad Short Form
Entire House
For: MW-208
2704 BENT PINE DR, FORT PIERCE, FL 34951
Job:
Date: Mar 11, 2019
By:
Htg Clg Infiltration
Outside db (°F) 43 91 Method Simplified
Inside db (°F) 70 72 Construction quality Semi -tight
Design TO (°F) 27 19 Fireplaces 0
Daily range - L
Inside humidity (%) 30 50
Moisture difference (gr/Ib) 0 65
HEATING EQUIPMENT
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
10.1
kW
34434
Btuh
17
°F
1833
cfm
0.054
cfm/Btuh
0
in H2O
COOLING EQUIPMENT
Make Carrier
Trade 16 SEER PURON AC
Cond CA16NA060""A
Coil FV4CNB006
AHRI ref 4585445
Efficiency 14.0 EER,
16 SEER
Sensible cooling
38500
Btuh
Latent cooling
16500
Btuh
Total cooling
55000
Btuh
Actual air flow
1833
cfm
Air flow factor
0.048
cfm/Btuh
Static pressure
0
in H2O
Load sensible heat ratio
0.71
ROOM NAME
Area
(ft2)
Htg load
(Btuh)
Clg load
(Btuh)
Htg AVF
(cfm)
Clg AVF
(cfm)
MASTER SUITE
333
6215
5890
333
280
HIS WIC
53
894
442
48
21
MASTER BATH
159
1685
2347
90
112
HER WIC
74
76
237
4
11
DEN
199
3886
3091
208
147
FOYER
86
1839
1729
99
82
DINING
161
2726
2751
146
131
MECH
38
486
718
26
'34
UTILITY
53
77
736
4
35
BATH 2
58
1007
963
54
46
BED 2
180
1887
2838
101
135
BED 3
178
1932
2854
104
136
BATH 3
58
1673
1179
90
56
REAR VEST
50
1197
1013
64
48
NOOK
99
3670
4423
197
210
✓lr Uu Ki
Onn
nne
.IGCI
4O
on
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Mar-13 12:14:04
,y wrightwft' RlghtSuite® Universai201212.1.05 RSU02818 Pagel
X& CAUsersUasonTocuments\Wrightsoft HVACWW-208.rup Cale =MJ8 Front Door faces: S
VMmmI RIVI
UTILITY HALL
41421
95
4411
319
D-1`Jl
293
Z6/
17
441
14
Entire House
2523
34216
38563
1833
1833
'Other equip loads
0
0
Equip. @ 0.95 RSM
36828
Latent cooling
15543
Tl1TA1 C
I ncnn
I nen.lc
.loon
I .loon
V I/l�V LJGJ JYLIV JLJ,V IVJJ IVJJ
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
2019-Mar-13 12:14:04
�- wrightsOft RlghtSulte® Universal 201212.1.05 RSU02818 Paget
�+� C:\UsersUasonlDocuments\Wrightsoft HVACWW-208.Iup Cato =MJ8 Front Door faces: S
+b- wrightsoft* Project Summary
Entire House
For: MW-208
2704 BENT PINE DR, FORT PIERCE, FL 34951
Notes:
Design Information
Weather: Vero Beach Municipal AP, FL, US
Job:
Date: Mar 11, 2019
By:
Winter Design Conditions
Summer Design Conditions
Outside db
43 OF
Outside db
91
OF
Inside db
70 OF
Inside db
72
OF
Design TD
27 OF
Design TD
19
OF
Daily range
L
Relative humidity
50
%
Moisture difference
65
gr/lb
Heating Summary
Sensible Cooling Equipment Load Sizing
Structure
28707 Btuh
Structure
28760
Btuh
Ducts
5509 Btuh
Ducts
9803
Btuh
Central vent (0 cfm)
0 Btuh
Central vent (0 cfm)
0
Btuh
Humidification
0 Btuh
Blower
0
Btuh
Piping
0 Btuh
Equipment load
34216 Btuh
Use manufacturer's data
n
Rate/swing multiplier
0.95
Infiltration
Equipment sensible load
36828
Btuh
Method
Simplified
Latent Cooling Equipment Load Sizing
Construction quality
Semi -tight
Fireplaces
0
Structure
12871
Btuh
Ducts
2672
Btuh
Heating Cooling
Central vent (0 cfm)
0
Btuh
Area (ft2)
2523 2523
Equipment latent load
15543
Btuh
Volume (ffa)
25539 25539
Air changes/hour
0.22 0.11
Equipment total load
52370
Btuh
Equiv. AVF (cfm)
94 47
Req. total Capacity at 0.70 SHR
4.4
ton
Heating Equipment Summary
Cooling Equipment
Summary
Make
Make Carrier
Trade
Trade 16 SEER PURON AC
Model
Cond CA16NA060****A
AHRI ref
Coil FV4CNB006
AHRI ref 4585445
Efficiency
100 EFF
Efficiency 14.0 EER,
16 SEER
Heating Input
10.1 kW
Sensible cooling
38500
Btuh
Heating output
34434 Btuh
Latent cooling
16500
Btuh
Temperature rise
17 OF
Total cooling
55000
Btuh
Actual air flow
1833 cfm
Actual air flow
1833
cfm
Air flow factor
0.054 cfm/Btuh
Air flow factor
0.048
cfm/Btuh
Static pressure
0 in H2O
Static pressure
0
in H2O
Space thermostat
Load sensible heat ratio
0.71
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
WI't Il$SOi3' 2019-Mar-1312:14:04
g RlghtSuile® Universal 2012 12.1.05 RSU02818 Page 1
C:1UsemVasonlDocuments%Wrightsoft HVACWW-208.rup Cale =MJ8 Front Door faces: S
HOMES
2702 BENT FINE DR
FORT FIERCE, FL 34951