Loading...
HomeMy WebLinkAboutEVALUATION REPORTSCANNED BY TRIMW ERD St. Lucie County EVALUATION REPORT GAF r R E C FILE COPY EXTERIOR RESEARCH €& DESIGN, I.I.C. Certificate of Authorization #9503 353 CHRISTIAN STREET, UNIT#13 OXFORD, CT 06478 (203)262-9245 Evaluation Report 01506.01.UH-R22 1 Campus Drive FL10224-R20 Parsippany, NJ 07054 L5T,-Uc:0 R 1 `� �019 Date of Issuance: 01/03/2005 (800) 766-3411 Revision 22: 09/20/2017 County, Permitting SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: GAF Asphalt Roof Shingles LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein and FBC 1507.2.7.1 / R905.2.6.1. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity)ERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity[ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at thejob site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 The fzoimileseal appearing was aWhodred by Robert Nieminen, Pmanai/20/2017. This dam not..rc..,an eleavom.1iysigned domment CERTIFICATION OF INDEPENDENCE: 1. Trinityl ERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither Trinity l ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 1 i{,, - "' ' TRIMY J ERD I ROOFING SYSTEMS EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Asphalt Shingles Compliance Statement: GAF Asphalt Roof Shingles, as produced by GAF, have demonstrated compliance with the following sections of the 6th Edition (2017) Florida Building Code and Florida Building Code, Residential Volume through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1507.2.4/1507.1.1, Physical Properties ASTM D1970 2015 R905.2.3 / R905.1.1 1507.2.5, R905.2.4 Physical Properties ASTM D3462 2010 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D3161 2016 1507.2.7.1, R905.2.6.1 Wind Resistance ASTM D7158 2011 1507.2.7.1, R905.2.6.1 Wind Resistance TAS 107 1995 3. REFERENCES: 99tiv Examination Reference Date GAF (PDM 1915) Letter of Equivalency Seal -A -Ridge Impact Resistant IR 01/13/2012 PRI (TST 5878) Physical Properties GAF-025-02-01 03/27/2002 PRI (TST 5878) ASTM D3462 GAF-059-02-01 09/02/2004 PRI (TST 5878) ASTM D3462 GAF-080-02-01 05/25/2005 PRI (TST 5878) Physical Properties GAF-324-02-01 12/01/2011 PRI (TST 5878) Wind Driven Rain GAF-407-02-01 01/21/2013 UL (TST 1740) ASTM D3462 93NK6295 11/29/1993 UL (TST 1740) ASTM D3462 99NK43835 01/12/2000 UL (TST 1740) TAS 107 94NK9632 03/29/2000 UL (TST 1740) ASTM D3462 OINK06632 02/02/2001 UL(TST 1740) ASTM D3161, TAS 107 OINK9226 05/21/2001 UL (TST 1740) ASTM D3161 OINK37122 12/18/2001 UL (TST 1740) ASTM D3462 O1NK37122 12/19/2001 UL (TST 1740) ASTM D3161, TAS 107 02NK12980 04/10/2002 UL (TST 1740) ASTM D3161, TAS 107 02NK30871 09/09/2002 UL (TST 1740) ASTM D3161 03CA5357 03/11/2003 UL (TST 1740) ASTM D3462 03NK26444 10/17/2003 UL (TST 1740) ASTM D3462 04NK13850 06/07/2004 UL (TST 1740) ASTM D3161 04NK13850 06/23/2004 UL (TST 1740) ASTM D3161 04NK30546 03/10/2005 UL (TST 1740) ASTM D3462 04NK22009 05/06/200S UL (TST 1740) ASTM D3161 04NK22009 05/09/2005 UL(TST1740) ASTM D3462 05NK27924 02/10/2006 UL (TST 1740) ASTM D3161 05NK27924 02/11/2006 UL (TST 1740) ASTM D3161,D3462 06CA18077 06/05/2006 UL (TST 1740) ASTM D3161, D3462 OGCA18074 06/16/2006 UL (TST 1740) ASTM D3161,D3462 06CA35251 10/18/2006 UL (TST 1740) ASTM D3462 06CA31603 12/01/2006 UL (TST 1740) ASTM D3161,D3462 OGCA41095 12/27/2006 UL (TST 1740) ASTM D3161 071\11(05228 03/13/2007 UL (TST 1740) ASTM D3161 06CA31611 04/04/2007 UL (TST 1740) ASTM D3161 06CA61148 04/09/2007 UL (TST 1740) ASTM D3161, D3462 07CA31742 11/08/2007 UL (TST 1740) ASTM D3161, D7158, D3462 OSCA06200 03/13/2008 Eiderior Research and Design, I.L.C. Evaluation Report 01506.01.08-1122 Certtfimte of Authodzutlan#9503 dn' EDITION (2017) FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 2 of 6 T �M Eta Katky Examination Reference Date UL (TST 1740) ASTM D3161, D3462 07CA55908 04/01/2008 UL (TST 1740) ASTM D3161, D3462 09CA10592 03/26/2009 UL (TST 1740) ASTM D3161, D3462 09CA06856 05/15/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09NK06647 08/01/2009 UL (TST 1740) ASTM D3161, D7158, D3462 09CA27281 08/27/2009 UL (TST 1740) ASTM D3161, D7158, D3462 10CA35554 03/05/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA13686 05/15/2010 UL (TST 1740) ASTM D3462 IOCA07264 05/27/2010 UL (TST 1740) ASTM D3462 IOCA11953 10/29/2010 UL (TST 1740) ASTM 63161, D7158, D3462 10NK11951 10/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 1ONK12070 11/04/2010 UL (TST 1740) ASTM D3161, D7158, D3462 08CA06100 01/30/2010 UL (TST 1740) ASTM D3161, D7158, D3462 10CA53934 03/31/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48924 10/22/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA47919 12/03/2011 UL (TST 1740) ASTM D3161, D7158, D3462 11CA48408 12/08/2011 UL(TST1740) ASTM D3161, D7158, D3452 11CA48725 12/09/2011 UL, LLC.(TST 9628) ASTM D3462 12CA34891 10/12/2012 UL, LLC. (TST 9628) ASTM D3161, D7158, D3462 12CASS151 02/15/2013 UL, LLC.(TST9628) ASTM D3161 12CA38083 02/26/2013 UL, LLC. (TST 9628) ASTM D3161 13CA32332 06/18/2013 UL, U.C. (TST 9628) ASTM D3161 13CA37934 08/02/2013 UL, LLC. (TST 9628) ASTM D3161, WISE, D3462 4786875675 07/17/2015 UL, LLC.(TST 9628) ASTM D3161, D7158, D3462 4787434542 05/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mobile, AL 10/25/2016 UL, U.C. (QUA 9625) Quality Control Inspection Report, R21, Myerstown, PA 10/20/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tuscaloosa, AL 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Michigan Cty, IN 11/01/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Shaffer, CA 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Savannah, GA 11/11/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Minneapolis, MN 10/25/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Mt. Vernon, IN 10/2512016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Baltimore, MD 10/21/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Tampa, FL 11/17/2016 UL, LLC. (QUA 9625) Quality Control Inspection Report, R21, Dallas, TX 11/04/2016 UL, LLC. (QUA 9625) QualityControl Inspection Report, R21, Ennis, TX 11/03/2016 UL, LLC. (QUA 9625) QualityControl Inspection Report, R21, Fontana, CA 11/01/2016 4. PRODUCT DESCRIPTION: 4.1 Asphalt Shingles: 4.1.1 Marquise WeatherMax®, Royal Sovereign® and Sentinel® are a fiberglass reinforced 3-tab asphalt roof shingles. 4.1.2 Camelot®, Camelot® II, FortitudeT , Glenwoodl°, Grand Canyon®, Grand Sequoia®, Grand Sequoia° IR, Grand Sequoia° ArmorShielcl ", Monaco®, Sienna®, Timberline° American Harvest®, Timberline® ArmorShieldT" 11, Timberline® Natural Shadow®, Timberline HD®, Timberline® Cool Series®, Timberline Ultra HD® and Woodland° are fiberglass reinforced, laminated asphalt roof shingles. 4.1.3 Slateline° is a fiberglass reinforced 5-tab asphalt roof shingle. 4.2 Hip & Ridge Shingles: 4.2.1 Seal -A -Ridge® Ridge Cap Shingles, Seal -A -Ridge® IR Impact -Resistant Ridge Cap Shingles, Seal -A -Ridge® ArmorShieldT°" Ridge Cap Shingles and Timbertex® Premium Ridge Cap Shingles are fiberglass reinforced, hip and ridge asphalt roof shingles. Etderior Research and Design, LLC- Evaluation Report 01506.01.08-R22 CertiJlcote o/Authodzodon#9503 6'a EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-R20 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 3 of 6 JTRINIrTY I ERR 4.3 Accessary Starter Strips. 4.3.1 Pro -Start® Eave/Rake Starter Strip Shingles and WeatherBlockerTM Premium Eave/Rake Starter Strip Shingles are starter strips for asphalt roof shingles. 4.3.2 QuickStart® Peel & Stick Starter Roll is a is a mineral -surfaced,, fiberglass -reinforced, self -adhering SBS modified bitumen starter strip, nominal 9-inch x 33 ft roll, for use with asphalt shingles with exposure of 6- inch or less. 4.3.3 StarterMatchTM Starter Strip Shingles are color -coordinated starter strips for use with Grand Canyon® and Grand Sequoia° series asphalt shingles. StarterMatchTM' are installed as the second starter for Grand Canyon® and Grand Sequoia® series installations. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither Trinity]ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically forthat purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Wind Classification: 5.4.1 The GAF asphalt shingles noted in Section 4.1 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F and/or ASTM D7158, Class H, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Vast =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.2 The GAF hip & ridge shingles noted in Section 4.2 are Classified in accordance with FBC Tables 1507.2.7.1 and R905.2.6.1 to ASTM D3161, Class F, indicating the shingles are acceptable for use in all wind zones up to Vasd =150 mph (Vuit =194 mph). Refer to Section 6 for installation requirements to meet this wind rating. 5.4.3 Classification by ASTM D7158 applies only to exposure category B or C, as defined in FBC 1609.4.3, and a mean roof height of 60 feet or less. Calculations by a qualified design professional are required for conditions outside these limitations. Contact the shingle manufacturer for data specific to each shingle. 5.5 All products in the roof assembly shall have quality assurance audit in accordance with F.A.C. Rule-61G20-3. 6. INSTALLATION: 6.1 Underlavment: 6.1.1 Underlayment shall be acceptable to GAF and shall hold current Florida Statewide Product Approval, or be Locally Approved per Rule 61G20-3, per FBC 1507.2.3, 1507.2.4 or R905.2.3. 6.2 Starter ShinelesorStarterStrip: 5.2.1 Installation of Pro -Start Eave/Rake Starter Strip Shingles, Weather13locker Premium Eave/Rake Starter Strip Shingles and QuickStart Peel & Stick Starter Roll shall comply with the GAF current published instructions. 6.3 AsphaltShinzles: 6.3.1 Installation of asphalt shingles shall comply with the GAF current published instructions, using minimum four (4) nails per shingle in accordance with FBC 1507.2.7 or R905.2.6, with the following exceptions: ➢ Camelot, Camelot II, Grand Canyon, Grand Sequoia, Grand Sequoia IR, Grand Sequoia ArmorShield, and Woodland require minimum five (5) nails per shingle. ➢ Slateline requires minimum six (6) nails per shingle. 6.3.2 Fasteners shall be in accordance with manufacturer's published requirements, but not less than FBC 1507.2.6 orR905.2.5. Staples are not permitted. 6.3.3 Where the roof slope exceeds 21 units vertical in 12 units horizontal, special methods of fastening are required. Contact the GAF for details. Exterior Research and Design, I.I.C. Evaluation Report 01506.01.08-RZ2 rerttfimte ofAuthorizatron M03 6tvEDITION (2017)FBC NON-HVHZ EVALUATION F1.10124-1120 GAF Asphalt Roof Shingles Revision 22:09/20/2017 Page 4 of 6 w� TRII+ERD 6.4 Hip & Ridge Shingles: 6.4.1 Installation of Seal -A -Ridge Ridge Cap Shingles, Seal -A -Ridge IR Impact -Resistant Ridge Cap Shingles and Seal -A -Ridge ArmorShield Ridge Cap Shingles shall comply with the GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and nominal 0.25-inch diameter beads of Henkel "Loctite PL S30 Roof & Flashing Sealant". 11.5' Sealant 1" (292 mm) 1. Sellante (ZS mm) (25 tpm) Enduit d 6tanch&6 �1 (905 Nall mm) Clavo 65/8" _7518° Clouer 12' (305 mm) 6.4.2 Installation of Timbertex Premium Ridge Cap Shingles shall comply with GAF current published instructions with a minimum two (2) nails, minimum 3/8-inch head diameter, per shingle and beads of Sonneborn NP3 Gun Grade Polyurethane Sealant or Henkel PL Roofing and Flashing Sealant. y� �d NOR C"r7 t :aver (005 nun) 5 (229Imn1P i — 17" FSsT5 iixlll 6.4.3 Fasteners shall be in accordance with GAF published requirements, but not less than FBC 1507.2.6 or R905.2.5. Staples are not permitted. Exterior Research and Design, U.C. Evaluation Report 01506.01.08-R22 Certiftate afAuthonzatlon#9503 61eEDITION (2017)F13C NON-HVHZ EVALUATION FL10124.RZO GAF Asphalt Roof Shingles Revision 22: 09/2O/2017 Page 5 of 6 ERD J TRINITY 7. LABELING: 7.1 Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. 7.2 Asphalt shingle wrappers shall indicate compliance with one of the required classifications detailed in FBC Table 1507.2.7.1 / R905.2.6.1. 8. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. 9. MANUFACTURING PLANTS: Contact the named QA entity for information on which plants produce products covered by Florida Rule 61G20-3 CA requirements. 10. QUALITY ASSURANCE ENTITY: UL LLC—QUA9625; (847) 664-3281 ENIb OF EVALUATION REPORT - Exterior Research and Design, U.C. Evaluation Report 01506.01.08-R22 C'eniloate ofAothari:otion 09503 0 EDITION (2017) FBC NON-HVHZ EVALUATION FL10124-1120 GAF Asphalt Roof Shingles Revision 22: 09/20/2017 Page 6 of 6 U ram APR 12 "9'9 ST. Ludo County, Permitting l�L � O I etc. Certificate of Authorization #32455 353 Christian Street, Unit #13 Oxford, CT 06478 (203)262-9245 ENGINEER EVALUATE TEST CONSULT CERTIFY o e Soprema, Inc. Evaluation Report S18010.06.09-R12 1640 rue Haggerty SCANNED FL2569-R14 Drummondville, Quebec J2C SP8 Canada Date of Issuance: 06/15/2009 BY (819) 478-2400 St. t' UC(e COun� Revision 12: 02/12/2018 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: Soprema Roof Underlayments LABELING: Labeling shall be in accordance with the requirements of the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. of any changes to the product(s), the Quality Assurance or the production facility location(s). NEMOJetc. requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "NEMO Ietc. Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 8. Prepared by: Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE1983 �ufinger"", T pO�cv`. ' Jo •..>�.. Qa,.{-;_ The facsimile seal appearing was authorized by Robert •r'S''O�•�'''-' Nieminen, P.E. on 02/12/2018. This does not serve as an ��� N l��n\ electronicallysigned document. CERFIFICATION OF INDEPENDENCE: 1. NEMO ETC, LLC does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. NEMO ETC, LLC is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. 5. This is a building code evaluation. Neither NEMOI etc. nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. NNEMOJetc. ROOFING COMPONENT EVALUATION: v• Product Category: Roofing Sub -Category: Underlayment Compliance Statement: Roof Underlayments, as produced by Soprema, have demonstrated compliance with the following sections of the 6t6 Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. Section Property Standard Year 1504.3.1 Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1507.2.4 / 1507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 2012 FRSA/TRI April 2012 (04-12) Physical Properties ASTM D6163 2008 TAS 110 Accelerated Weathering ASTM D4798 2011 Ent( Examination Reference Date ERD (TST6049) ASTM D1970/TAS 110 2968.05.04-2 05/14/2004 ERD (TST6049) Physical Properties 2757.02.05 02/03/2005 ERD (TST6049) ASTM D1970 / TAS 110 2974.03.05-2 05/17/2005 ERD (TST6049) Wind Resistance 2778.07.05 07/15/2005 ERD (TST6049) Wind Resistance 2779.11.05-R1 04/18/2007 ERD (TST6049) TAS 103 / TAS 110 S7120.11.07-2 11/02/2007 ERD (TST6049) ASTM D1970/TAS 110 S13190.02.09-R1 04/01/2010 ERD (TST6049) ASTM D1970/TAS 110 S31370.03.10-1-R1 04/07/2010 ERD (TST6049) Physical Properties/ Tensile Adhesion S11150.05.10-R1 09/09/2010 ERD (TST6049) Physical Properties/ Tensile Adhesion S11150.05.09-R2 10/05/2010 ERD (TST6049) ASTM D1970 S37210.11.11 11/09/2011 ERD(TST6049) ASTM D1970 S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties/Tensile Adhesion S43530.02.14-1 02/21/2014 ERD (TST6049) Physical Properties/ Tensile Adhesion SOPC-SC7645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SOPC-SC8520.14 04/17/2015 ERD (TST6049) Wind Resistance SOPC-SC14045.05.17-R1 06/07/2017 M-D(CER1592) HVHZCompliance 15-0508.04 09/24/2015 ]CC-ES(EVL2396) 20151BC Compliance ESR-1524 03/01/2017 PRI (TST5878) Physical Properties SOP-064-02-01 12/03/2013 Soprema, Inc. (PDM3511) Equivalency Declaration SA SMOOTH PLY 40 06/29/2015 UL, LLC (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4.1 Lastobond TU HT is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 4.2 Lastobond Shield is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.3 RESISTO SA SMOOTH PLY 40 is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment; available in 3.3 ft x 65 ft rolls; meets ASTM D1970. 4.4 Lastobond Shield HT is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. NEMO ETC, LLC Evaluation Report 518010.06.09-R12 CertJjlcate DfA0hunzadan#32455 eEDmON(2017)FBC NON-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 2 of 8 ONEMOletc. 4.5 Lastobond Pro HT-N is a self -adhering, woven polyethylene surfaced, SBS modified bitumen roof underlayment available in two widths; 36 and 45 inch; meets ASTM D1970. 4.6 Lastobond Pro HT-S is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D3970. 4.7 EnviroShield is a self -adhering, woven polyethylene surfaced, high temperature, SBS modified bitumen roof underlayment; meets ASTM D1970. _ 4.8 Lastobond 195 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.9 Lastobond Eaves Protection Sheet is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.10 Lastobond Eco is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970, 4.11 Lastobond Smooth Seal HT is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970. 4.12 RESISTO LB1236 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.13 PrimeSource Grip -Rite Eave & Valley Protector is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.14 , RESISTO LB1244 is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 44-inch sheet width; meets ASTM D1970. 4.15 Colphene FR GR is a self -adhering, fiberglass reinforced, granule -surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012 (04-12). 5.1 This is a building code evaluation. Neither NEMO ETC, LLC nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this report; refer to current Approved Roofing Materials Directory for fire ratings of this product. 5.4 Soprema Roof Underlayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: •m • � .OPTIONS Wood or Slate or Underlayment Asphalt Nail -On Foam -On Metal Composite Composite Shingles Tile Tile Shakes & Slate Shingles Lastobond TU HT Yes Yes Yes See .1 5.5 yes Yes _ Yes Lastobond Shield/Pro HT-N/ Yes No No No Yes Yes RESIST' SA SMOOTH PLY 40 _ Lastobond Shield HT/ Pro HT-5 Yes No No Yes Yes Yes EnviroShield Yes No No Yes Yes Yes NEMO ETC, LLC Evaluation Report 518010.06,09-1112 Certfjfcute ofAuthorizotion#32455 0 EDITION (2017) FBC NON.HVHZ EVALUATION F1.2569-1114 Supreme Roof Underlayments Revision 12: 02/3Z/2018 Page 3 of 8 NNEMO I etc, TABLE 1: ROOFC6VEFC o Wood or Slate or - Underlayment Asphalt Nail -On Foam -On Metal Composite Composite Shingles Tile Tile Shakes & Slate Shingles Lastobond Eaves Protection Sheet / yes -- No: -- - - - °=No- No Yes - -Yes_ Lastobond 195 Lastobond ECO / RESISTO LB1236, — -- - - - -- - -- - -- - - - - ' — Grip -Rite Eave & Valley Protector / Yes No No No Yes Yes RESISTO LB1244 Lastobond Smooth Seal HT Yes No _ _ _ No. _ Yes Yes Yes Colphene FR GR Yes Yes Yes No Yes Yes See 5.5.1 5.5.1 "Foam -On Tile" is limited to use of following Approved tile adhesives / underlayment combinations. TABLE Adhesive • �bHEtiVE,/ UNDERLAYMENT Florida Product Approval COMBINATIONS Underlayments Dow TileBond- FL22525 Lastobond TU HT ICP Adhesives Polyset® AH-160 FL6332 Lastobond TU HT or Colphene FR GR 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244 or Lastobond Smooth Seal HT applied to: ➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. Colphene FR GR applied to: ➢ Plywood; ASTM D41 primed plywood; ASTM D41 primed structural concrete. Note: ➢ While not required over plywood, OSB or Southern Yellow Pine substrates, Soprema recommends priming with Elastocol Stick or Elastocol 600c if the final roof cover is not slated for installation within 24 hours. ➢ Soprema requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. 5.6.2 Bond -to -Insulation: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastoband 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Lastobond TU HT only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulation/underlayment system in accordance with FM 4474, Appendix D, Testing Application Standard TAS 114, Appendix J or UL1807. I Refer to Tile Manufacturers or Adhesive Manufacturer's Florida Product Approval for overturning Moment Resistance Performance. NEMO ETC, LLC Evaluation Report 518010.06.09-1112 Certificate of AuthofizaVan#32455 ErnEDITION (2017) FBC NON-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 4 of 8 NNEMO etc. 5.6.3 Bond to Mechanically Attached Base Laver: Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond TU HT, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond ECO, RESISTO LB1236, Grip -Rite Eave & Valley Protector, RESISTO LB1244, Lastobond Smooth Seal HT or Colphene FR GR applied to: ASTM D226, Type I or II felt; Sopra-G; Modified Sopra-G. For installations under mechanically attached prepared roof coverings, base layer shall be attached per minimum codified requirements. For installations under foam -on tile systems (Lastobond TU HT only), base layer shall be attached in accordance with FRSA/TRI April 2012 (04-12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-22) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2.to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12) or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure = -45.0 osf Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #2 Maximum Design Pressure =-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Elastocol600c Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered. #3 Maximum Design Pressure=-150.0 psf: Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Lastobond TU HT, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end - laps. #4 Maximum Design Pressure =-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Base Sheet: Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c. in three (3), equally spaced rows in the center of the sheet. Underlayment: Lastobond TU HT or Colphene FR GR, self -adhered 5.6.4.1 All other direct -deck, adhered Soprema underlayment systems beneath foam -on tile systems carry a Maximum Design Pressure of -45 psf. NEMO ETC, LLC Evaluation Report S18010.06.09-R32 Certificate of Authadutfon#32455 6mEDITION (2017)FBC NON-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12: 02/12/2018 Page S of 8 ONEMOletc. 5.6.4.2 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table IA. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WD3, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for tone 2/3 enhancements. 5.7 Exposure Limitations: Lastobond Eaves Protection Sheet, Lastobond 195,Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave & Valley Protector or RESISTO LB1244 shall not be left exposed for longer than 30-days after installation. Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT or Lastobond Pro HT- S, EnviroShield shall not be left exposed for longer than 90-days after installation. Lastobond TU HT or Colphene FR GR shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12)): When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. • •• Tile Profile DIIkECT-[DECKTILE INSTALLATIONS Staging Method Maximum Slope Underlayment Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 30-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) Lastobond TU HT Lugged Flat Max.10-tile stack 5:12 Colphene FR GR Lugged Max. 10-tile stack 6:12 NEMO ETC, LLC Evaluation Report S38030.06.09-R12 Certificate ofAuthorizotton N32455 6P EDITION (2017) FBC NON-HVHZ EVALUATION FL2569-1114 Soprema Roof Underlaymems Revision 22: 02/12/2018 Page 6 of 8 NNEMO I etc, 6.1 Soprema Roof Underlayments shall be installed in accordance with Soprema published installation requirements subject to the Limitations set forth in Section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris prior to application, and prime the substrate with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER (if applicable). 6.3 6.3.1 Lastobond TU HT, Lastobond Shield, Lastobond Pro HT-N, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, Lastobond Pro HT-S, EnviroShield, Lastobond Eaves Protection Sheet, Lastobond 195, Lastobond Eco, Lastobond Smooth Seal HT, RESISTO LB1236, Grip -Rite Eave 8, Valley Protector, RESISTO LB2244 or Colphene FR GR: Shall be installed in comoliance with the requirements for ASTM D1970 underlavment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile Applications., While priming is optional, Soprema recommends priming with Elastocol Stick, Elastocol 600c or RESISTO EXTERIOR PRIMER if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 30 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-inches and staggered not less than 2-ft from vertical seams in the course below. All over -granule end -laps shall be sealed using either heat -welding or hot air welding techniques. When installing at slopes above 8:12, Soprema recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Lastobond TU HT or Colphene FR GR only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and Soprema published requirements for tile staging. As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. MEMO ETC, LLC Evaluation Report S38010.06.09-1112 Certifimte ofAvthorizadonN32455 0 EDITION (2017) F8C NON-HVHZ EVALUATION FL2569-R14 Soprema Roof Underlayments Revision 12:02/12/2018 Page 7 of 8 M( NEMiO etc. Contact the noted QA agency for information on product locations covered for F.A.C. 61G20-3 QA requirements. The following plants have qualified products under their respective physical properties specifications. Plant Specification Products) Lastobond Shield, RESISTO SA SMOOTH PLY 40, Lastobond Shield HT, LastobondProHT-N, Lastobond Pro Hi EnviroShield, Lastobond 195, Drummondville, ASTM D1970 Lastobond Eaves Protection Sheet, Lastobond Eco, Lastobond Smooth QC (Canada) Seal HT, RESISTO L61236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/fRI 04-12 Colphene FR GR Wadsworth, OH Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB3236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 ASTM D1970 & FRSA/TRI 04-12 Lastobond TU HT; Colphene FR GR Lastobond 195, Lastobond Eaves Protection Sheet, Lastobond Eco, Gulfport, MS ASTM D1970 Lastobond Smooth Seal HT, RESISTO LB1236, PrimeSource Grip -Rite Eave & Valley Protector, RESISTO LB1244 UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - NEMO ETC, LLC Evaluation Report S18010.06.09-R32 Certflfla of Awhorization#32455 11 EDITION(2017) W NON-i EVALUATION F1.2569-R14 Soprema Roof Underlayments Revision 12: 02/12/2018 Page 8 of 8