HomeMy WebLinkAboutSHED PAPERWORKSETUP AND INSTALLATION OF SINGLE WIDE SHED FILE SETUP AND INSTALLATION OF DOUBLE WIDE SHED 1. BUILDING IS PLACED IN REQUESTED LOCATION ON SCHEDULE 40 PVC TO ALLOW FOR MOVEMENT TO PLUM OR SQUARE UNIT TO HOUSE, FENCE, PROPERTY LINE, ETC. 2. ONCE UNIT IS SQUAkE AND THE HIGH SPOT OF THE GROUND 15 ESTABLISHED, THE BUILDINGIIS BLOCKED ON THE HIGH SPOT AND LEVELED. THE OTHER END OF THE BUILDING IS BROUGHT UP TO LEVEL AND BLOCKED. THEN THE CENTER OF THE BUILDING IS SUPPORTED TO LEVEL, BLOCKED, AND THEN SHIMMED. 3. AFTER THE BUILDING IS LEVEL, MORE BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 4. ANCHOR PLACEMENT IS ESTABLISHED BY THE WIDTH OF THE BUILDING. HOLES ARE DRILLED THRU THE 2"x4" BOTTOM PLATE WITH A 1/2" AUGER BIT. 1/2" EYEBOLT OR OPTIONAL 1/2" THREADED ROD (FOR A "HIGH SET") IS SECURED THRU THE HOLE. 5. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. 6. IF THE UNIT HAS A FLOOR, EITHER A HOLE IS DUG FOR THE 30" AUGER ANCHOR AND BACKFILLED AND SECURED AS PER THE DETAIL OR A 1/2" HOLE IS DRILLED INTO THE CONCRETE 1-1/2" OFF OF RIM JOIST. THE EYEBOLT IS FASTENED THRU THE BOTTOM PLATE AND A SIMPSON A-24 (OR EQUAL) IS SECURED TO THE CONCRETE WITH A 1/2" WEDGE ANCHOR. 7. IF THE UNIT IS A 'NO FLOOR' OPTION, ANCHOR WITH 1/2"x5" WEDGE ANCHOR THRU THE 2"x4" BOTTOM PLATE. TABLE 1 ANCHORING TO CONCRETE SHED WIDTH UPLIFT (PLF) ANCHOR SPACING 20'-0" 400 S-6' 13'-B" -280 S-6" 11,-8" 240 3'-6 10'-0" 200 S-V 8'-0" 160 S-6" 6'-0" 120 S-6- TABLE 2 SKID RUNNER SPACING' SHED WIDTH X1 X2 X3 13,-B" V-10}' 1,_10)" 1,-1q' 2'-B" 6'-4" - 10'-0" V-7" 61-10" - W-O" 0'-9" 6'-6" - 6'-0" 0'-10" 51" - •VALUES ME FROM END OF JOIST TO CENTERS OF (2) 4%4' SKIDS ONLY. 13'-8' WIDE SHEDS HAVE (4) SETS OF SKIDS. 1. BUILDING IS PLACED IN REQUESTED LOCATION. THE FIRST SECTION OF THE DOUBLE WIDE IS PLACED ON THE HIGHEST LOCATION OF GROUND AND IS LEVELED UP. 2. BLOCKS ARE THEN PLACED AT THE END, CENTER, AND OTHER END TO LEVEL. ONCE THE BUILDING IS LEVEL, BLOCKS ARE ADDED TO ACHIEVE THE CORRECT SPACING (SEE TABLE 3). 3. THE NEXT SECTION OF THE SHED IS BACKED INTO PLACE AND UNLOADED PARALLEL WITH THE FIRST SECTION. THE TWO SECTIONS ARE CONNECTED AT THE LOWER CORNER WITH (1)1"x44" BOLT AND NUT. THE SECOND SECTION IS THEN LEVELED AND THE OTHER BOLT HOLES ARE LINED UP AND BOLTED SECURE. THE REST OF THE BLOCKING IS THEN COMPLETED. THIS PROCEDURE IS REPEATED FOR MULTIPLE SECTION SHEDS UNTIL ALL SECTIONS ARE IN PLACE. 4. GROUND ANCHORS ARE THEN ADDED (SEE TABLE 4B). 5. ONCE THE BUILDING IS PROPERLY BLOCKED AND BOLTED TOGETHER, THE SUPPORT BRACING IS REMOVED. - 6. ANCHORS ARE NOT REQUIRED IN THE BOTTOM PLATE FOR DOORS AND DOORWAYS WITH NO FOOTER (GARAGE DOORS FOR EXAMPLE). HEADER DESIGN TRANSFERS THESE LOADS. TABLE 3A PAD TYPES TYPE PAD DIMENSIONS MAX. LOAD- MATERIAL I 2"x8"x16" 1778LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX II 4"x8"x16' 3500LBS CONCRETE BLOCK QUALITY CEMENT AND SAND MIX III 16"x16" 3950LBS ABS PLASTIC PADS IV 8"x8"xi6" 190OL13S CONCRETE BLOCK QUALITY CEMENT AND SAND MIX • BASED ON 2000PSF SOIL BEARING CAPACRY (2000PSF IS TYPICAL) NOTES 1. HOLLOW OR SOUD CONCRETE BLOCKS (8'x8"x16') MAY BE STACKED ON PADS FOR HIGH SETS UP TO 48' WITHOUT REINFORCING. 2. ABS PADS REQUIRED ON II'-B' AND IV-8' WIDE SHEDS ONLY. TABLE 3 SUPPORT FOOTING PAD SPACING FOR RUNNER BLOCKING FOR SINGLE & DOUBLE WIDE SHEDS SHED DESCRIPTION PAD MAXIMUM LOAD AND PAD TYPE SHED WIDTH LW(PLF) END PAD MAX. SPACING END PAD SIDE RUNNER PAD TYPE INTERIOR PAD SIDE RUNNER PAD TYPE 13'-8" 4.15/332 Cr TO 6" 6'-0" 1936LB I, It, III, OR IV 1879LB I, II, III, OR IV 11'-8" qSW/DW 6.00/480 0" TO 6" 6'-0"2558LB I, II, III, OR IV 2555LB I, II, III, OR IV 10'-0" 5.00/400 0" TO 6" 6'-0" 2400LB I, 11. III, OR N 2400LB I, II, III, OR IV 8'-0"4.00/320 0" TO 6" 6'-0- 2029LB I, II, III, OR IV 2133LB I, II, III, OR IV 6'-0" 3.00/240 0" TO 6" 6'-0" 1658113 I, II, III, OR IV 1866LB I, II, III, OR IV • LOAD WIDTH OF UPLIFT ON RUNNER NOTES 1. PAD SPACING IS END TO CENTER OF PAD. 2. PADS OTHER THAN END PADS SPACING IS CENTER TO CENTER. 3. USE SAME MAXIMUM SPACING FOR INTERIOR SPACING. GENERAL NOTES & SPECIFICATIONS FOR AUGER ANCHORS 1. BUILDING ANCHORS SHALL BE "MOBILE HOME" TYPE HP-1 SINGLE HELIX EYE AUGER ANCHOR BY HOME PRIDE OF BRISTOL, VA. OR EQUAL. AVERAGE HOLDING STRENGTH IS NOT LESS THAN 4,900 LBS. 2. ANCHORING SYSTEM TO GROUND PER LOCAL BUILDING CODE (BY DEALER). LOCATE ANCHORS PER TABLE 4A OR 48. 3. THREADED ROD WITH EYEBOLTS SHALL BE PLACED THRU THE BOTTOM PLATE (FLOOR SYSTEM) AND ATTACHED TO ANCHOR. THESE CAN BE EXTENDED WITH THREADED ROD (OR STRAPS WITH EQUAL OR GREATER STRENGTH) FOR ELEVATED PORTIONS OF SHEDS ON LEVELING BLOCKS. TABLE 4A 30" AUGER ANCHOR SPACING - SINGLE WIDE SHED WIDTH LW UPUFT (PLF) END ANCHOR" MAX. INTERIOR SPACING... 13'-B" 7.00 243 V-K1" TO V-O" 10'-0" i V-8" 6.00 208 V-0" TO V-0" 10'-0" 10,- " 5 00 sl 174 t0'.�"-#OT3�0"-1 AiK"QJ�V - 8'-0" 4.00 138 0'-0" TO S-T 10'-0" 3.00 104 0'-0" TO S-T 10'-0" TABLE B 30" AUGER ANCHOR SPACING - DOUBLE WIDE SHED WIDTH LW UPUFT (PLF) END ANCHOR" MAX. INTERIOR SPACING••• 20'-0" 10.00 1 400 1 0'-0" TO 3--0' 1 5'-0" • LOAD WIDTH OF UPLIFT ON RUNNER •` LOCATION FROM END WALL OF AUGER ANCHOR ••• MAXIMUM SPACING BETWEEN ANCHORS. NOTES 1. ANCHOR SPACING IS DESIGNED M PER ASCE-7. 2. ALL MEASUREMENTS ME CENTER -TO -CENTER. 3. THE MINIMUM NUMBER OF ANCHORS PER SHED IS (4). (1) ANCHOR PER EACH CORNER. ADDITIONAL INTERIOR ANCHORS ME REQUIRED IF SPACING IS MORE THAN 10'-0' BETWEEN MCHORS.. 4. ANCHORS SHALL BE ON SIDE WALLS EXCEPT WHEN THE SHED IS PLACED NEXT TO AN EXISTING BUILDING; IN WHICH ANCHORS CAN BE PLACED ON THE END WALLS AS CLOSE TO THE SIDE M POSSIBLE Tirl-tIVED T1/2- APR 12 201 2"x2' GALVANIZED WASHER Permitting DeparE 2'x2' GALVANQED WASHER WITH 1/2' NUT THREADED ROD 'HIGH SC. Lucie Count WITH 1/2' NUT OPTIONAL FOR SET NOTCH OR COUNTERSINK BOLT 1/2' THREADED ROD--,,,, OPTIONAL FOR 'HIGH SET" �' EYES BOLTED TOGETHER WITH 1/2'x2" BOLT & NUT WITH (2)2"x2" GALVANIZED 1/2• COUPLER THRU 2"W 8070M PLATE 2"xb" BOTTOM PLATE NAILED 1/2' COUPLER 1 /2'x12' FORGED EYEBOLT ', % �• WASHERS (2.000IB SHEAR CAPACITY) :: - %( MIN. • �4 e I s 1/2'x5' (400 LB.) CONCRETE WEDGE ANCHOR INTO AAB P.T. BOTTOM PLATE THRU(S TO 2'x6' P.T. BASE -----�--MIN. I • •� EYES BOLTED TOGETHER WITH 1/2'x2'� n � 1 E TA (SEE TABLE 1 FOR SPACING) U--------°------- J_ BOLT & NUT WITH (2)2"x2" GALVANIZED TypE t, It. II, OR N PAD WITH OAE 1. It REQUIRED (SEE TABLE 3). 1/2N3" (400 Ul) SIMPSON A-24 CONCRETE SLAB BY OTHERS THROUGH CONCRETE SLAB BY OTHERS THROUGH WASHERS (2.000LB SHEAR G4PACftt) CONCRETE WEDGE ANCHOR CUP OR EQUAL LOCAL CODES AND JURISDICTION LOCAL CODES AND JURISDICTION 30' EARTH AUGER HOR (SEE TABLE 1 FOR SPACING) (SEE TABLE 4 FOR S cING> SPHED WITH SKID SHED WITH SKID SHED WITH 'NO FLOOR' OPTION Ti UADiQRi•BLOG�kd G ANCHORED TO CONCRETE ANCHORED TO CONCRETE TIE -DOWN DETAILS 7B -3 A77 CODE VERSION fBG 201T ESN FSSi /SCE-7 A MMUFACTUPER 6URAOR SHE05 I BUILDING TYPE REBOEHR4 IAWN sOR.WE CONSTRUCRON TYPE V-B FIRE PROTECTION NONE FIRE SUPPRESSION SYSTEM NONE OCCUPANCY STOWE ALLOWABLE NUMBER OF STORIES 1 BASIC WIND SPEED vr2Wmvn ENCLOSURE ENCLOSED INTERNAL PRESSURE COEFFICIENT a/- 0.10 IMPORTMCE FACTOR 1.15 ROOF DEAD LOAD IOPSF ROOF INE LAND 20PSF OR 3001. FLOOR DEAD LOAD 6PSF FLOOR WE LOAD Sn). 7.w - 125P OPT. MODULES PER BUILDING 1 HURRICANE PROTECTION USAGE NO HURRICANE SHELTER USAGE NO SOUME MOIACE U35 THIN M s03T. 1 2 (GROUND ANCHOR V ALES WAX. MGIOR ExTQbHIN I0/20/151 1BO '11 U) MTB p oGee: L J 4/26/16 = scale: U) N/A oEel (yJ ALL GENERAL NOTES 1. FOUNDATION PUNS ME NOT PART OF THIS PUN SET AND ME GOVERNED BY LOCAL JURISDICTION. L.LJ 2. THIS BUILDING IS EXEMPT FROM THE FBC J ENERGY CONSERVATION CODE PER SECTION 1015.22. M 3. REFER TO TIE -DOWN DETAILS FOR PROPER INSTALLATISfiEW1TiE6dB�9'�TO MEET CODE Q V BY LLI J �7 Z U] I A ICJ 0 D 0 0 6/1/18 Q M9Ythew T. Baldwin Flariita license rs Q Z Sheet:-1 PSI APPROVAL 2018-01-18 D4 ALUMINUM ROOF SHEATHING '-0' MAX. ,nJ m n_ 0 71.4RUNNERS O m END WA. . TRUSS 0 2 1 TRUSS D.G. M 24 MAX. - FNn Side Wall Header Schedule (180C) End Wall Header Schetlule 180C S¢e{d) ktax. Span NJtb) Fasteners w/o strap (each3 gels Building Width Fastener w/ strap Up to W Wide 1-2'k4' 6'-0" 0 A x 0131) Sze { each en Max -Span NJ(b) 2-Tka^(c) 1 9'-0" 0{d1 s- -x . 3t rle s I-Wx4' G-P 0 3-3'x 0.131'nails a. etetl •2luas era rNo. grade supprt Iron ar. 0 Led Number afjeck studs ragwratl [o supCort each end. c. NO -le tl- No Jack stlA+,, but 2x6 sNds lad let. 4'k4" VfZ'A4' B'-0' 1 6 -3° x 0.13l' nails a. Tabulated vAlues are for No. 2 grade Spence-PNe-Fu lumber. It. NJ- Number ofjack studs required to support each end. c. Window header for window openings that hale more than 60ab combined stud wall abae •N� and below, othermse use door header schedule. d. See header details for alternate layouts, i.e. 2-2'x4' or 4'x4' P.T. t. six uslauR solmlRE roaAlworivsE FxwREfio'Is % I¢�nn so nl a a. The hearer can be attached to the top plate and thus have the combined strength * W C= sa tuna i ANa A WAff Tc oom xrAms equivalent and use the maximum span stated. WxE slurs 1 11 I 1 I 1 I 1 IXILbDR 1 I 111 9YAT4NC IFA2n ]•�• j it 11 i i I W11X 1/3• RYMA.0 II l i l ' as ose nun m tlM'.4• OR OR; I I II 1311]' tli 14'M' 4T{IFflI W415TK. M11f65ECIPUD 12' MAX ' SA �IRxI HYDROVENT DETAIL SIDE WALL WINDOWS END WALLS WINDOWS & OPTIONAL & DOORS DOOR B' WIDE OR LESS 2 CODE INFOR TION CODE VERSION vs YRP — —m A�-r. ]a14 Ac SH' 4,4 4°x4° W/2%4" MANUFACTURER SUPETeaR seTs BUILDING TYPE IAspnaPa u sraY4E CONSTRUCTION TYPE v-a FIRE PROTECTION NIwE FIRE SUPPRESSION SYSTEM NWE OCCUPANCY sNWrLE ALLOWABIB NUMaE OF STORIES 1 BASIC WIND SPEm v.-taonYN EXPOSURE c ENaDSORE o+c,nsm INFORM PRESSURE cGeFFaENT e/- ala IMPORTANCE FACTOR 1.15 (, I9�I/1 ydOrfek ROOF DEAD WAD 10 OUTLET + NOTES -OPTIONAL ELECTRIC ROOF LIVE LOAD 3 F OR 3a115 POM IMa -ALL WIRING SHALL BE 14 GAGE 3-WIRE MC CABLE. BOOR DW IAM tins N -ENCASE IN ALL METAL BO%ES. ,d �?Y N SOURCE ,:._. <. ,.. FLOOR VVE LOAD sin- TSPSF - 12E Off. DESIGN PRESSURES L tl WIRING DIAGRAM T =T»a 3,e •'2•Fr •R' RATING OF wN.Ls. FL00R. ROOF WA MOauu3 PER Bul.ONG ROOF +z7.a -Ba.7 ROOF FRAMING PLAN -•-•=.='i.]: 33^ WALLS/DOORS/WINDOWS +3z.B -zB.z (OPTIONAL) Puy. u.».-.vNm.cm:a., PE HURRICANE PROTECTION USAGE No vLVE AenTa,u vE x<roxT _ IsaacYuoxxx,Tx vsnxosn HURRICANE SIMM USAGE W - Ynu w NPPx S.5- Bin WAB •pacR A WmmW 1LG1x1N5 vARv SQUARE FOOTAGE TIS sarr. aR IEsS REVISIONS rsEO N. 3•'4' ter'"' Max aR CANE z• �0 °aM REV DESCRIPTON DATE BY aR Tan / / ; ; 51ffAT1eyO aPnots r Muc % r wN Nx anAa . ac S / / e41Ne®E MTB DO e: J 12/12/17 3 do H N A xs send o N4 sac 1u*E (!) W (f) adel 2C o.¢ 4xx nwR F.WRIc z SS-9-180CR1 soLL PLA. sNE PLUS W I. iPMW flNiS IRE Nor PAW OF T65 PIMI SiT on A'e nee, MAW�a � 2 n115s BNLpNa� &aW TILE FHC ENERGY LdI50NAM ALL STUDS SSI4Sa TO. GOIE PCnE w J IYIOE PFA iat512 VLt AhL F,aar FRAMNc wnl aan• 1- a ]. RFPm TQ TIE- WJAl15 TnR PROPER INSTAUATmN El LI nmml•+r sw W/5-1M NNr STANDARD WALL DETAIL m WM WUE n1A i- B19YE A I> m 4. N13iue5. RMEp$ TRU$, ARE ELT- J ENW. WITH DOOR & WINDOW OPTIONS Ta11KN11ON mE ro RocP At0 ,E To mN"W' lawn PATH. WXFAE W�Nt RIE11eERs A� F' O SPURS. USSE ETC N4 Iz Sn. FXaPr /a Nolen. WnC. e'-0• m IYa' AI✓an S-0' ro IY-e' nnon s¢awllc - a/1' RYlyaao Mar WNnNUWE. 9M1Et 4Erk aAma n6,5. iCItlI.T 6 rJLVNUIgD W AOr IE4 SIRUCNI¢.5 OVER 10a m. iT. WILL HIVE AN BO' 46ii11W ELEVATION CROSS-SECTION END ELEVATION 4-.a• P.r. Amain Wml - 3/A' P,T. RTAWa 3 4 Tx AWL 6E SIFR nuN our la%i]tAL TRaelEss w p•aR. e. OnTUM TO ee flora L ON-mE BY 000c; nwO Law- TYPI AIu ARAM WITH DOOR T c2 . a�uWnrY - s%4' P.T. *as w O r. " Cori To Mix, me WNNW sPEsa =Ns seeaxc. I SM a (x) SM- LW r1AT NA A WG d VAS N{ HR4W g z,R' IAm MT xr ]a] nbE BaaR FRaaa wx A¢ss e'c To 1r-0- uus ¢' f TO Ir-01 END ELEVATION END ELEVATION 'd 4Ax 9m 11OI11 x, A A ,r-e• r-,O• ,•-IN• r-,d• 1 r-e• r-s• Y-4• - la'-0'- 9'-0• a-T• Cd 5-0• U'-10' 61• - TI fi O ' I I �K�.AI xP r.mnmrlw sm.v' 4i,Y<•Me®W[t9 ma vvm Y D I I 3.5 P.T. 24• ox. Tin. OP110WL 12 O I" Me. M *" 3/v TAE Rladlal ` P.T. ATI" W,fR R14 aR EawAIENT. SUE s 2 rax QuQM Mn I I I I I W As F A IrmaNc CODE A FLV 4flk STU=5 aW BE �NNr ASWNo mR1C,u14L MEtA9BS aF W.4,- SNOT. 1RA5ES CNOfroS. EIG io 11E1P SECV!✓- TIES£ T. MLVBOSi PINIOm TINT n1E IDOa) 0<11a oam Naf a11Q5EPE BRWFS P! 1NE STiM l�V L\CENS f '% ly ii VI LLJ 2 STATE :,% Ur Matthew T. Baldwin P.E. Z Florida Ucense #64608 now JOIST. sa somRAE FOR SUE WITHOUT DOOR WITH GARAGE DOOR w M (OW 0`16c*&D FLOOR FRAMING PLAN F m Sheet: SSB— -I 1 OF 1