Loading...
HomeMy WebLinkAboutPRODUCT REVIEW AFFIDAVITC`''"7`K Planning & Development Services Department z C S Building & Regulations Division Product Review Affidavit q Building Permit # I 1 CH — D350Dwners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes 0.ECENED APR 2 4 g019 �eRnittln9 D par ment St. l.uGe NVR - Business Use Only SCANNED BY St. Lucie County Product Opening Design Pressures Product Rated Design Pressure Manufacturer Model# Product Approval Number Glass Type Method of Attachment Windows +32.37/-42.62 +50.2/-50.2 PGT Industries SH-200 17-0630.02 non -impact 010 Wood Screw with sufficient length to achieve 1-1/4' embedment. Required anchors: Head(3), Jamb(3) Mullions N/A +/-75 PGT Industries PGT 17-0630.01 N/A Use X."Tapcon with sufficient length to achieve a l'/."min. embedmentwith 2 A' minimum edge distance Fixed Glass +29.65/-38.87 +/-58.9 PGT Industries PW-220 17-0614.05 non -impact JI 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head(3), Jamb (3) Sliding Glass Doors +28.74/-42.62 +35.3/-89.6 PGT industries SGD-2500 18-0207.05 non -impact 3/I6" Tapcon with sufficient length to achieve 1-1/4" embedment. Required anchors: Head/Sill(6), Jambs) Swing Type Doors +30.64/-30.64 +67.0/-67.0 Therma Tru 3'0"x8'0" FL 5891.5 N/A I]: Tapcon X", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4'. Anchor Spacing Max 19.5"O.0 Garage Doors +25.91/-31.39 +36/-42 Clopay 160 model 73W6 FL 16546.4 N/A Jamb to block on vertical Jamb 1/4" X 1114" min embedded Tapcon. Max spacing of 71/2" and 1" OD steel washer requlred. Hurricane Protection N/A +40/-40 Eastern Metal 24ga Steel Panels FL 11964.2 N/A 1/4"Tapcon Anchors, SG Tapcon or 1/4"X3/4". All points Solid -set Anchors. Roofing Material N/A N/A Tamko N/A FL 18355.1 N/A Soffits (Panel Walls) N/A N/A Ply Gem Mastic Soffits FL 23352.1 N/A Structural Component N/A N/A Huber Eng. ZIP System FL 17147.2 N/A i have reviewed me above components or wadding and I nave approved their use In this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: James Joseph Cantwell Signature:_ LAMES JOSEPH CANTWELL .rfti42AzRphsJly Design Prof: Architect Cart. No. AR0012079 Date:_ 4/16/2019 Planning & Development Services Department Building & Regulations Division Product Review Affidavit Building Permit # Owners Name: NVR Inc DBA Ryan Homes Applicant: NVR Inc DBA Ryan Homes SCANNED BY St. Lucie County NVR - Business Use Only Product Opening Rated Product Design , Design Approval Product Pressures Pressure Manufacturer Model # Number Glass Type Method of Attachment Windows +32.37/-42.62 +50/-60 DP Ply Gem Series 4712 Flange FL 14039.1 non -impact #,10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3) Mullions N/A +/-7S DP Ply Gem Series 4700 Flange FL 15264.2 N/A Use Y<" Tapcon with sufficient length to achieve a 1 Yo" min. 'embedment with 2 Y=" minimum edge distance Fixed Glass +29.65/-38.87 +/-55 DP Ply Gem Series 4701 Flange FL 14434.1 non -impact # 10 Wood Screw with sufficient length to achieve 1-1/4" embedment. Required anchors: Head (3), Jamb (3) Sliding Glass Doors +28.74/-42.62 +/-50 DP Ply Gem Series 4780 FL 14634.2 non -impact 3/16" Tapcon with sufficient length to achieve 1-1/4" embedment. Required anchors: Head/Sill (6), Jamb (5) ITW Tapcon Y", Min Embedment 1-1/4", Min Clearance to edge 2", Min Clearance to adjacent anchor 4"; OR ELCO Tapcon 1/4", Min Embedment 1-1/4", Min Clearance to edge 1", Min Clearance to adjacent anchor 4". Anchor Swing Type Doors +30.64/-30.64 +67.0/-67.0 ThermaTru 3'0"x8'0" FL5891.5 N/A Spacing Max 18.5"O.0 Jamb to block on vertical jamb 1/4" X 11/4" min embedded Tapcon. Max spacing of 71/2" and 1" OD steel washer Garage Doors +25.91/-31.39 +36/-42 Clopay 160 model 73W6 FL 16546.4 N/A required. Hurricane Protection N/A +40/-40 Eastern Metal 24ga Steel Panels FL 11964.2 N/A 1/4" Tapcon Anchors, SG Tapcons or 114" X 3/4". All points Solid -set Anchors. ' Roofing Material N/A N/A Tamko N/A IFL18355.1 N/A Soffits (Panel Walls) N/A N/A Ply Gem Mastic Soffits FL 23352.1 N/A Structural Component N/A N/A Huber Eng. ZIP System FL 17147.2 N/A I have reviewed the above components or cladding and I have approved their use in this structure. These products provide adequate resistance to the wind loads and forces specified by current code provisions. Name: lames Joseph Cantwell Signature: Design Prof: Architect Cert. No. AR0012079 Date: _ 1 10 2019 Jam eq. gned P+' J. g `�y�D°e .w Gam � Q i2019,g1< II // ......-0s'oo,