HomeMy WebLinkAboutTRUSS PAPERWORKSOUTHERN TRUSS COMPANIES Southern Truss 2590 N. Kings Hwy Fort Pierce, FL 34951 (772) 464-4160 * Fax: (772) 318-0015 Job Zmber. J18004992CircJle /� 7 Customer. Ryan Homes 6j Lo�, Name: Oakland Lake - Lo Address: 5336 Oakland LakCity, ST, Ilp:Fart Pierce, FL 34 General Truss Engineering Criteria & Design Loads Building Code and Chapter: FBC2017frP12014 Computer Program Used: MiTek Version: 8.23 Oct 2 SCANNED 37.0 p 37.0 psf ROOF TOTAL LOAD N/A N/A St. Lucie County Wind Building Authority: 160 mph from MWFRS(Envelope) ASCE 7-10 (Low Rise) St. Lucie County No. Date Tneis IDlt 1 11/14/18 Al 2 11114/18 A2 3 11114/18 A3 4 11/14118 A4 5 11114/18 A5 6 11114118 A6 7 11/14/18 A7 8 11114/18 As 9 11114/18 AM 10 11/14118 A10 11 11114118 A110 12 11/14/18 CJ2 13 11/14118 CJ8 14 11114/18 HVe 15 11/14118 J2 16 11/14/18 J4 17 11114/18 J4A 18 11114/18 J6 19 11/14/18 J6A 20 11/14118 J8 21 11/14118 J9 22 11114/18 J9AG 23 11/14118 J9G 24 11/14A8 K4 25 11/14/18 KSG 26 11114/18 MV2 27 11/14/18 MV4 This cover sheet is provided as per Florida Statute 61G15-31.003 in lieu of signing and sealing each individual sheet. An Index sheet of the truss designs is attached which is numbered and with the indentificaticn and date of each drawing. Engineer of Truss DesigntPa'ILE COPY Brian M. Bleakly FL Reg. Eng. No. 76061 2590 N. Kings Highway Fort Pierce, FL 34951 Page 1 of 1 This cover sheet is provided as per Florida Statute 61G15-31.003 in lieu of signing and sealing each individual sheet. An Index sheet of the truss designs is attached which is numbered and with the indentificaticn and date of each drawing. Engineer of Truss DesigntPa'ILE COPY Brian M. Bleakly FL Reg. Eng. No. 76061 2590 N. Kings Highway Fort Pierce, FL 34951 Page 1 of 1 TYPICAL DETAIL @ CORNER - HIP ~ NOTE: NDS=National Design Specifictions for Wood Construction. 132.5# per Nail (D.O.LFactor=1.00) nds toe nails only have 0.83 of 'lateral Resistance Value. 12 0 1& OVER �O 9-9-5 CORNER JACK GIRDER ALLOWABLE REACTION PER JOINT UP TO 265p — 2-16d NAILS REG-D. Q UP TO 394# = 3-16d NAILS REO'D. J7 use 2-16d toe nail TC & Bc. n Typical jack 45' attachment use 3-16C toe nail TYPICAL CORNER LAYOUT & 3-16d Typical Hip —jack attachment CHORD HANGERS FASTENER GIRDER JACK J1—J3 TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — BC — — — — — —— 2-16dnails ————— J5 TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — BC — — — — — —— 2-16dnails --——— J7 TO HIP GIRDER TC — — — — — — — 3-16d nails — — — — — BC — — — — — —— 2-16dnails — — — — HIP JACK GIRDER (C,17) TO HIP GIRDER TC — — — — — — — 3-16d nails — — — — — BC — — — — — —— 2-16d nails — — — — MINIMUM GRADE OF LUMBER LOADING (PSG FM INCR_ DDx T.Q.2z4 SYP 2 L 0 FEC2D17 6.C. 2a4 SYP #2 . TOP 20 wms 2.4 SYP No3 Bomm DD 10 SPACING 24' O.D. 4-SOUTHERN TRUSS COMPANIES hW/�.seatnarm,aamm Fort Pierce Division 2590 N. Ke,9FL Highway. Fort4951 (SDD)232-0509 (772)464-4160 Fax:(772)318-0016 Brian M. Bleakly Struct Eng #76051 2590 N. Kings Highway, Ft Pierce, FL 34951 772-454-4.16D TYPICAL DETAIL (9 CORNER - HIP NOTE NDS=National Design Specifictions for Wood Construction. 132.5# per Nail (D.O:LFactor=1.25) nds toe nails only have 0.83 of lateral Resistance Value_ 12 1OVER _ wz) 1-0 EgG) HIP GIRDER 12 O 15� -0-14 CORNER JACK GIRDER ALLOWABLE REACTION PER JOINT ® UP TO 265# — 2-16d NAILS REQ'D. UP TO 394# = 3-16d NAILS REQ'D. use 2-16 toe nail TC & Bc. Typical jack 45' attachment i J1KMGRMMDER) J3I � of I toe nail Q TYPICAL CORNER IAYOUr & 2-16d O n Typical Hip —jack' attachment CHORD HANGERS FASTEN ER GIRDER JACK J1—J3 TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — BC — — — — — —— 2-16dnails — — — —— JS TO HIP JACK GIRDER TC — — — — — — — 2-16d nails — — — — — BC — — — — — —— 2-16dnails — — — —— TC ————--— 3-16dnails — — — — — BC —-——--— I 2-16dnails — — — — — HIP JACK GIRDER (CJ5) TO HIP GIRDER TC — — — — — — — 3-16d nails I — — — — — BC — — — — — —— 2-16dnails — ——— IIMUM GRADE OF LUN T.C. 3a4 SP 0 B.G - 2a4 EYP /2 WEBS 2:4 SYP N0.3 L O TOP. TO BOTTOM 00 10 SPACING 24' O.C. For TRUSS t Pierce Division 2590 N. Kings Highway, COMPANIES (800)232 0509'(772)46�160 Fox:(772)318-0016 Brian M. Bleakly Struct Eng #76051 2590 N. Kngs Highway, Ft Pierce, FL 34951 772-464-416D Hangers Face Mount Hanger Charts iTeW ':Iobtsim - stodrt74 "Rd.No. 54e1:. amw OiveosunaMi - fastenm5dleNUex'` - :OFh7' , AOowa6b!Wade . 0 H �LL Code '.. Ref.:... E:.Neadei ,.. Joist.' W..: - _Nf `e' - '. A_` •b0d Mai :' �- ,--Nail ; '.,-- - Nam, -Rom Rod OprtlP 100%115%125% J124 11124 20 1-SM6 3 1-12 15M6 - 4 tOd 1 2 1 lad x1-112 1..470 5401'S90.;1 320 5, R5, F2 4 1fid. 1 2 70dz1-i2 560 64g". 695" :320 JL24{FTZ - 1B 1_M6 3-1/B 4 11 HDG 2 1IX1-12 HDG 455 535 -ggO.j. 2Bg'.: 31, R1, F32 4 'Ed HOG 2 16dX1-1/2 HDG 550. 6151.675. 280-. 2x4 JUS24 UIS24 18 I-MB 3-18 13/4 1 4 10d 2 10d 675.:775 W5 510J 7 SUH24 U24 16 1-9H6 3-1/4 2 1-3M6 - 4 10d 1 2 10dxl-12 500 .550 {+6055; 330 S. 4 16d 2 I 10d x 1-12 590 1 665 ' 72D 31M HD26 HU26 14 1-8/16 3-12 2-12 14/8 4 16d j Z iDdx 1412 ,eM- 745'j .3G5' B5, F2 Max 4 _615 615 695.1 745 { 595 -. - JL2fi I 1M16 20-. 11JI76 •1-ms -_- 43/4-11721556 S .'10tl - {.d : tOdxt-12" 710 605: 1":870,. 650:' 6, '.']6tl 4 ,;..70tlz7-72 _.:'9401.9sD199045-'650;,. ' J126T-12 Wzez 18' 9-12 1'12 _ _ 6 :1DdJiDG ,.4- 10dz1-172HDG 695 ROO 1 970 730' 11 31, R7, i F32 6' 16d HDG 4` 10dx1-72HDG -930 -.950 1 10M 730 -'JU525 1J1$26 -r'18 -:1 t-anti 4-Y3h61.374 i >'4 =,•10d'. .,4 ' 10d': - 87Z 100(111080 1115 i; S,RS,F2 !NM926-, "�' FMUS26 -: 78�':. I-WIC,-`51116 2 S. -: .' 6' =:-10d 6 - .•-10d. __ .--,11285 1475 .16051� a65' 31, R7, F32 -2a6 _ '_SI11178 - 126 _. _ . 16 .71J/i6 , 5718 � -. _. 2 ]3J1fi _ . e . '6 -10d, 4- •�-00tl z1-IJ2 750 'MO I S10 755-_: "S ' 16d,- 4 10d7<7-12- '890 1DO01. 1080 :755.. - 'HUS26' . .411326 1- 16 MA ! S7/I6' 3 -2 ` 144 16d ' '..6 1 16d'..-.: .. 27601314013345'. 1925 - -. HDZ6 - HU25- -14 _'' 1-9/i6 .3-12-.. Z412 1-1/8' . : 41lo • Ma d 16d , 2 ��,. 14 1 1Odz1-12 1�. ' - - 615 '05 745 -. 385' 5, R5, 615 693 745 BE ' 110)28 HI178 14-% 1-9116 S1W R/R ,7-1/8 Ulu- -max, e' A6d 1 d "]-... 6 - 11bx1-12 .-1Z30 1230 199011490 •780 F2 139011A90 825' X26 U26 20 1-MS 4-3/4 1-12 15MG - 6 10d 4 1 10dx1-12 710 8D51. E70 650: 6 16d 4 10dx1-12 840 960,{10451 650 JL261F-TZ LUC26Z 18 1-9M6 4-12 1-1/2 - _ 6 1Dd HDG 14 110dx 1-12 M06 -69511 8D0 c870! 730 31. R7, F32 6 16d HDG 4 10dx1-72HDG ` 930i .950 '1035`730 '+ an Una 20 1-06 6-3/8 1-12 15116 _ 10 lod 6 Torx1-11Z 1780 1295 12951 �am- 5, R5, F2 10 i6d 6 10dx1-12 1400 7000 174D1 855 ' JL28F-TZ - 18 1-e/i6 6-1/8 142 - - a 10d HDG 4 10dx1-12HDS 131 1065 .1160:�. 730- I F-R1, F32 8 16d HDG 4 10dx1-12 FB1G 1105 1215 1215'. 730 JUS26 LLIS26 18 1-9/16 4-13/16 13/4 1 - 4 10d 4 10d 870 1000 90801'.1115 JUS28 LUS28 18 1-Mfi S5/8 1-3/4 1 6 10d 4 10d 111011270 13751 1115 S. RS, F2 2x8 MUS26 MIIS26 18 1-3/I6 5-in6 2 1 - 6416dj 1� 1285. 7475 760.5'. 865' 31, R7, MU528 MIIS28 18 1-MIS 7-1116 2 1 e lad 1710 1970, 2140'1 1230 F32 SURM U26 16' i-9M6 5-118 2 1-3M6 _ 6 10dx1-12 �:750 840 910{-'-755' 6 10dx7-12 '$80 1000 10M ;, 755 SUR28 - 16 1-9/16 S5/8 2 13/16 8 10dx1-112 -1000 1120j 1210 � BUD, 8 lGdxi-12 1175 1335 1440.1 800 1ALTS HUS26 16 1-5/8 5-7116 3 2 - 14 16d 6 16d 2760 314G 3345,1..1925 5 flizu HLIS28 16 1-518 7-3116 3 2 - 22 16d 8 16d 4170 4345 430.51 2570 ' R5 F2 HD28 tN28 14 1-W16 S1/4 2-12 1-1/8 8 16d 10dz1-12 8 '1230 1390 1490'1. 825' HD210 HU210' 14 1.9/16 7-3R6 2-12 7-1/8 58n 10 16d 4 lad 1-1/2 7540 1Td5 IWM 780:.. Ma 14 6 �$ 24302610 1178 11 Uplift Imdshave been haeased 60%for wind or seismic loads; notudlwrinmeasedu0 he permitted. ' 2)16d sinkes(0148 dm.x3-114•long) may be used at 084 of the table load where 166 cummonsam speci ed.This dog not applyto JUS, HUS, MUSsWdnall hangers. 3) FmJUS, HITS, and MUS hangers Nails mostbe driven site 30'to 45'angle through thejoist mtruss mto the headerto addeve the table loads. 4) RAMS` 10dx 1-1/2' nails we 0.148' dia x 1-12' long, 10dnxOsam 0.148' dia x 3' long, 16d nab one 0.16T dia. x3-12' long. New pmducls or updated product information me designated in him font. Cdrroslon Finish E5lainle-w Steel 1 GOId Coat EEHDG OTriple Zinc 112 CDrltinUed an next page Copyright 0 2018 Weir Industries, Inc. All Rights Reserved Ca ry T� m 4s10d v u0 .9romon P y� n r�r./y� ^ .. rr�� rr�A ' 14�i .- W W Qy n� {eq n pm n T y� n W F aE• oW n n Bryn of of r p� I ,r Oi O yp� (� pµ O py O spy N N tll pp W pp to p W C V ' pp1 ^ {y�� N 4V {py N N Cr ttVV yy� fO .. -. o s�Vp�1EGWQ��yGm����4m��$p��O�yC��s�r���������G�y�sI��$GdR9R1 �VF�"�5��9-?- 6 y��M�C�y�GM n r r r n r F ., F Q 'o 'o 'o�r� ^. ,o ,.��'oa �'o���e "b ���B�o�� u �i�7-7 Us .Aw r .- r 7r r �r n r n n r r .- .- .- •* r ,�r a�{.W � ':. •,.—gyp O y IY p IG p IO p m y O y IO p fO yy W W .^ �py 9 m yyy O V G 2 S q9p•p 0 W S v a 3 3 y a � * m py O N s pq a's o W �� �p 110 y W .� 77 W W rN.. }�- � I I I I 1 I I 1 1 I � � � � 1 I. I I 1 I I I � � � '� � � � � 1 ri 1,` I I )� � � r� � 1',1 � �% � •�_�. .�� 4 � a r r r.? .^, j.. I I � r 1 r. •- � I -. GN N C NNN N. C N;V C .C' rNN N N NNNN C C C C 11IN N:' N Nnl � NNy.r JTJm .V' ee22 3 I eR e� d " � @ee Eee m 4rre eri ,.� " ... m M ri �h „y J, ,h m N rh �i ',�,'' Jr r: rb m rn J, r.' r' � N n ri. n d+ rr6 � n 1. v� :r n � rh � � •. lr �h w .h �h oS m m e3i �S �h e5 nS - m oS oS rS M r1r ,n rir di ch rh m oS ni .th m w c1r m d1 t. d1 p�'f _pW 1O QYQm 10 �VQ Qt VWW �O W QdQQ Q Q Q mW tp 10 4�`Q 7,QdrQ T rQ•.� 7, I I 1 I r,-'�'� x� ��-' 4 :7.= � ,=•1:.�.� � ��-' ��� � 'S= '� 'Sc � � � �'.�. .� � � is • N1 �j N� (TI H N �fN� N INj� t�l .JN,tWLt-1l l� (�1 tCl N W Ol ,JN. A W Ib c6 (-` d d �N � N j d Y {� fV f(VV Z;i % X % X �N+ x r ?� u �3 cw ti a Sal g m X ■ 113 O�� p5,m fn Q is M.61 1� O SI �Fii �GiZ v m O d 'c SJGOUVH Hangers Face Mount Hanger Charts M iTe ke - ;foist Size - Stocit8; - .:pet. No. - Gauge Dimmsions(n1 -ltener5dredukx'°'r - -. DF/SP ` u Z� ltad Ne1:. Maz _ W -H' 0 -A - pa8 Nap Aoor IIpItH�. 100% 115% 125% ZW SlIH314 U314 16 2-9/16 10-9'16 2 1-18MAL24 tOd 6 tOdx1-12 2250{ 2525 2TL5 .1135 1fid 6 10dx1-12 2645 3000. 3010 1135 HD314 HU314 14 2-9116 11-5116 2-12 1-18led 8 10dxt-72 2455 36% Z780 .2980 41M 4435.. 1290 2045. 12 3x16 HD3141F HUC314 14 2-9H6 11-5116 2.12 - led 8 led x1-12 2465 .278U 2980 .1280 12 MISS 4170 4435-. 2045" HD316 FN376 14 2-9/I6 18-5I16 2-12 1-78 Min 18 tad 8 lodxl-12 8. '3125 3355 . 1560 11 Max 26 12 4005 4435 4435 2D45 HEM67 HUr316 14 2.9/16 13-5116 2-12 - Afire 18 lad 8 tOdxt-12 T770. 3125. 3355 156p M� t2 M � � (2)3xe. 11038-2 ;" i HU3B-2:, ,. ;14 - 5-118 - 6-iB 2 V2 19I6 t6d : - tOd:- _ .1540 173¢ 1�5 7811 - ..' .Maxi 14 6 2155 24M =a .. d170 HD38-2 HU38-2 14 5-18 6-18 2-12 1-18 Min t6tl 10d 1540 : 1735 INS 1- 780 Max10 14 64 2155 2430 2610. 1170. (2)3x10 HD310-2 HU310-2 .14 5-118 8 14M Min 14 led 6 tOd 2155: 243D 26101'. 1170 MaY 20 10 3090 3475 3725 1625 - (2}3x12 AD3122 HU312-2 14 5-18 . 10 ..Mmr r2-112 7-118 Mm ' . 16 24 - - Y6d: 8 10d ':. 2465 2780' 2980 7D65.. 12: 3695..4170 4470. '234065 (2)3xl4 HD312-2 HU312-2 14 5-118 10 1-1/8 16 led led 2780129M E4040 �� 24 1Y 4 4470 -.. ilUSZS33 . _.1 LOs263. 18'.-. 4-5181 4-112 :..2 1 -.� -4 •l6d._ 4-_ led ._. 1040' 1185 .1220� 1355 -- - SIHE - ,^ 1126-3 1fi 4518 3,1/4 2 1 ' 8 led ... 2. 10d - 1000: 1120 1165 _380'"' 8.:. led 2 101i- 1165 11. 1165 380 {3)2x6°- M HU263' - 14,' '4-5/8 III .. 412 2-1/2 1-1/8 1fid' x- 6 1- . 1230 AM 149D 780 : 5, Niai 12 :185O '200 2235 � 1170 - .. - :: .1M263F _ ' RUC26-3 : 14, 4-1 472. 2-12 •: - Min . 8; s ` _ t6d '.. ,:: 4 j e :1230 10A - _ :1390 1490. ,.780 F2 FZ 12. 6- 1850 2085. 2235' ..1170- JUS26-3 LUS26-3 18 4-5/8 4-12 2 1 - 4 led 4 led 1040 1185 1220'.- 1355 JUS283 LUS28-3 18 4SM 6-3/8 2 1 6 16d 4 led 1325 1510 1645 '1355 SUH26.3 U263 16 4-5+8 5-1/4 2 1 8 led 2 10d 1000: ,1120. -1165. 3BW 8 16d 2 led 1165 1165 1165 ` 380 HD263 NU26-3 14 45B 412 2-12 1-18 Min 8 16d 4 10d 1230 ;1390 1490 '780 Max 12 6 1850' 20a6 2235 1170 (312x8 HD28-31F HUG26-3 14 45R 412 2-12 - Min e 18d 4 18d _LM 1311 1490 - 780 Max 12 6 1850 2085 2235. :'1170. HD28-3 - 14 4.58I 6-38 2.12 1-18 Min 10 led 4 10d 1540: 1735 1865. --788 Max 14 6 2155 24M 2610.; 1170. HD23-.%F - 14 4-541 6.3/8 2-112 _ Min 1n led 4 led 1540 1735 1869 "780 Max 14 6 2155 '243D 2610. -1170 ,... -" -JUS7B-3'; "-.' 1-.LUS28-3' 18_: 4-518 6-38':'.;2 . 1 '.-. 6.: :: 16d- :4: led: ,'.1325 ,1510 1645 €1355- ' JLW0-9..,- f-!11tc� M . '18 ` -4518 8-318• ': 2 -1 -'.. a,- N6d' 6 -,16d:- 1845 '2105 'MO , 1980'.. D2103., •78 ' 4-518 &3.8.: ;: 2• 1 _11414 �.70d'-. b aOd"= 1750 1965 :2120 . 1135 14. `2060'23352520'.7135 4=518 &W , 2-12 1-18t6d 10 /4 - .. 4 , •.,: °, 1735 Y865.::780i14 . 8' 2155 2430 2610 -117014, 4516 6-3I8 212104:7540 ::'.= ..-„ _ 77351865 :=760�,14 B - 2155 2430 2610 .1170 � HU2103°; 14 '4i18 8-1/4 2-'iTt 71Bled 14- 14 "- . .. 6 70 •• .r led _ ,-;_,• - 21552610 ,117D 'HD270-3 '21553475-alEO,14 :. -M210-31F_ HUG2103 14. ±1-518 8-7F1 2=12 -2D ...' 1 6 •10. tOd;..- 2155 2430 200 1170. 3W,.3SM 1y50.. 3.HUfA210-3 ' 14'. •.43r3 .. ,,9.- _8 Y=1 ,2' :.W53 " 6. • -.vM ,.;. 5015 5598 5580 2U5'1 1131,1111,1`321 W: 1) Uprft bads have been Increased 60%tnrvdnd or seismic loads; no tuMer bcrease SW be pemul0ed. 2)16d sinkers(0.148 dia xS-114'long) maybe used at 0.84 of the table load when: led commons are specified. This does not apply to JUS, HUS, hWS slant net bangers ' 3) WS3 Wood Screws are 1/4° x 3' long and are Included with HDO hangers 4) NMIS 10d oohs ere 0.148° dla x 3' ",16d fdlsare 0.162° dia. x 3-12' beg. New products w updated product Information are designated m hbalwat Corrosion Finish Stainless Steel EGDed CDat MHDG � nple Zinc 4 n ». H Continued on next page 117 Hangers Face Mount Hanger Charts Mew JoistSize - -. USP-'L SWsk N4 savlo.:' Steel 6argB Dimensions (m) - FastenerSdiedulezD'' .-. 1)FIV Atlawa6le leads (ILsa 0 „ Cade Si` Ref. xeader Job W -� H= D t48717' Max: Nail s NaU- Flom`; 1(0% Root. - 119%125%. Upllw irD% JUS46 LUS46 i 18 3-5/8 5 2 1 4 16d 4 1611 j 10401 1185 12201 1365 - S1M46 1146 16 3-9/16 4-13116 2 1-1/B _ 10 Intl 4 Ind 9250. 1405 :1515 '755.- 10 16d 4 10d 11470.j.16/0 1800 755 N946 H1R46 14 3-518 1 5 1 2 1 4 tad 4 l6d 110511235..1300 1155`j --- 4x6 HUS46ff HUSC46 14 1 3-513 1 5 1 2 1 4 16d 1 4 16d 1108511235 13D0. 1155.; ' H046 HU46 14 3-9716 &1/i6 2-1/21-1/8 Nlin 8 t6tl 4 10d it 12�. "and 1490 780'r Max 12 6 ZED 2085 2735 `1170 H0460= HUCAfi 14 &9hfi 5-1116 2-12 - Mn 8 1� 4 10d 1230. 1390 149D 780:' Max 12 6 1ffiO�2088 2235 1170, _ - JUS46 ', IUS46 "[:... 18, 3.518i. : 5 ... `2:-{ 1 = � 4.. _. ?.16d, 4• ..-16d`-." 1040: 1785 1220 7355 b 16d5'�1.•16d;.; 1325:75101645{.1355-- •. -SUH46-- -•. 1p16" ;, ,. - . _", : 16 3-9716 - 413p6 2� "1-1/8 . i = `. .ID 1Ud? 4 10d r 1250. 1405 1515 •755 - 10 : 76d.. 4'' 10d-.... 3470. IBM7800. 755... 1111546 _":' 14 3-W8 1 `5 '.2..., 1 : - 4' 1 16d- � 4 - --i6d--::.:.1085 1235 '13D0 1165<: _ HUS46F Lam'. HUSC46 < 14 3-5/8 , 5 a 2 -1= - .'4 1 "16d =: d : . ' ]6d. .' INS 1235 1300 1155' 74 . '3-5/8 7 - 2-. -1 1 =-' 6 ,'tfid` 6 ' ...i6d_ : 1625 UB50 -7995 1870:° HUS481F ',-'..; HUSC48 _`.- 1-0 i,3•SB� 7 . r 2' i • I _ = 6 16d.:: 6 .:-l6d 7625 1850 1995' . 1810 4X8 ND46 HU46 &tfl6$12 7-7/86d. MaX: 8' 12 r-. ;_ 4 • .... tOd... ,_ IM 139D 1490. 780 6- 1850'{ 2085 2235: 1170 HD461F-',. 1fU= : Ons 5.1716 2-12 ' - .Min8 -: l6d-. 4. - '10tl ..- 1230j 1390 1490 .780..: 5, R5, .Riax' t2` 6- IBM 2085 2235. 1170, .. H= 14 3-9/I6 6-15116 2-12 • 1-1/8 Mtn; 1"Allax . 10 : Y60 : '4 ,YOG " �. _. `1640 1735 1855{. 780" F2 14 6 2155. 2430 2610 .1170. - ,_ HD48ff . , - OIlICAB • 14 . 3-9116. &15Fl6 - - 2-12 i - - Ian. 10 ,- 1fid'.`. a .' .- tOd: - ; .:.:. 1540. '1735 18fxi. - 780'. Mex_ 14 6 2155 2430 2610 1170. JUS48 LU548 18 3-511 6-7/8 2 1 - 6 16d 4 1f� 1325 1510 1645 1M JUS410 WS410 18 3-5(8 &718 2 1 8 16d 6 16d 1845 2705 2290 7980 SUH410 U410 16 3-9116 "a 2 1-118 _ 16 Ind 6 10d 200D 2245 2420 ..1135 - 16 16d 6 10d 2350.:26M 2880 1135 HUS48 JIMAS 14 3-5/11 - 7 2 1 6 16d 6 16d 11625. 1850 1995 1810: HUS48ff HUSC48 14 3-5/e 7 2 1 6 16d 6 lad 1625 :1850 1995 1B70- HD48 HU48 14 3-9/16 &15M6 2412 1-1/8 Min 10 led 4 10d 1540 1735 1665 780 -, Max 14 6 2155 2430 2610 11111• 4x10 HD481F HUC48 14 3-9/16 6-15/16 2-12 _ Mdn 10 166 4 1� Y540 1735 1865 '.780-' Max 14 fi 2155; 243D 2510'. 1170- HUS410 HUS410 14 3-5/8 B-7/8 2 1 8 lad 8 l6d 2170 '2465 -26M 2210'' HUS4101F HUS(M1O 14 3-58 B-7/8 2 1 8 16d 8 l6d 2170'.2465 2660, -2210, _ HD410 H114f0 14 3-9/16 &13116 2-12 1-1/8 Min 14 16d 6 1nd 2155 UM 2610 '.1170 - Max 20 10 3080 3-475 ..1 ,.. HD4101F RUC410 14 3.9116 8-13116 2-12 _ Min 14 16d 6 10d 2155 2-030 2b10. ;'1170: Mat 20 10 30B0 :3475' 3726 :1950 HDD410f HUM410 14 Mn 9 3 1-12 12 WS3 6 WS3 5015 5590 5590. 2975`> 31, R7, F32 1) UpOh loads have been Increased 60%forwinl orseimnic Inds: no further increase red be permitted. 2) t6d sbkers(0.148 ft x 3-1/4" long) maybe used at (L84 of the table load where 16d mmmmn; are specified This does rot apply to J16, HUS, M16stant nall halters. 3) Wa3 Wood Screws are 1/4- x 3" long and are included With HDO hangers. 4) NA05: 10d nails are 0.148' die x 3' Mng, tad nags are 0.162" die. x 3-12' beg. New products or updated product information are deGtignaled in blue trod. Corrosion Finish EStaiNess Steel 1336old Coat MHD6 ETriple Zero 119 9z'L 9L't mm W4 dSd 96 Ob OV01 1V1QL isd 00 WO 11 08 dsd Ot Ot 1Q 00 dsd 9t •Ot 1Q QL dsd OZ OZ 11 OA ONIWVtld ' 11V130 1NIOP dlH�1VNOadb LLE • 1VOMA QN3 O S I1VNO/LL/do 1e10 ay ROIiAB aOL(n) OHJIL7 3Wntl9 p'ZL(Z) N Arm •NMOHS IN im 03WHId NO 3HVIW6 30 AM QHONi N01100 • a—xt W3•ion low pH5300 iHODH 1p1"Jyum 3)LL sV ON01 SV 111ns 30 1.VYi SHVdS U30W1 G+) BSnHl 3H1 i0 2,H dd01 31LL ONVUB tl MM"d/dO Alms 3HLS HA .. UMNIOM NO DAMS SV OHOIVdS HHUnd i0 AM M a3SA C 6GM A311VA AR UO NO1530 GMS ,943NIDN3 NO ORAMS 3S91N3P SV a0 '00 itt V SNnH , SOMM Aa11VA OL HOOM O311ddV OHULLVSHO OWU 'Oa110V11V I,AaOd ' 'HHM 03OVUa 30 iSAN 135 AMA HLVAN30 IMIL 30 OUONO dOL ',0-,Zt Q33ON3 LON .IVR 1HO01H 'IVOWI3A A311VA HnWaMW e-1 WU U31V3H0; S0aM A7TVA 'MOI�pA. UOi '3OVds A71VO03 'ON�ONO �vVf 6A311NHNOO'HO '00 ,O.AV s•IA)! L9'x�46O1'O) aOBPO N0A1 YOB fLrV+Ha-2 YrL .1 NO 3a MIOR SAO[ t11MOH3ON O3llUIOUS SH HOW R���p����77]]7p�pyyA 311V A ONLWOddns XD)N 00-10Z XDW„0—,9 XD HQ— Q yy Sy Ni .. NOVi. n0—'s, mluo I& MOa10N0 • ',[Rd O-W OL QNIIA'=MOMS -0'dW 'OWintns 03561ON3 7HWOH Wild —•WWN RM—a •,'r Wt WOI Nod O311Y41-30t SINN 47L a AM'0) IOW PWI M UW A ISSNIL ONONOddOO AM OL ASINA MM HMW (10) CVWVAOS HO OSMM %NO V WOW d3dd1H 70 WW WMQ• W idtloq 10 91 dA6 baZ MGM F Q is Z#/tf ids No NZY ds of ao f.)c�e NwW nag jolt!- 4 Z%/tg Ads La dAs m •WagO dal a3BWn1 d0 3GVHS WnwtNlVi 9 M3 O'0 „ Z 1V ONIOWs 09 P00•7 lo)ol unWIXow '631YId "033N OtA/�30 � NYdd u a °' d5.1141YY X31V1tl up•6 0—.l` NYHL�fi�Stl3°1 i�6 LIB '.O-Y NY%G n a3 0 'WON31 wgvam 031d 10 X09 d0 "n"'ll v 38 LsnW ONI0YN0 .1. •s3Noz Nzams •00 .3:0t1Y s3NO2' N3 .Bl 00cs99 IV Ia •a5�sy°awroasti°Izai.(� 9° .t 1. fTll�(t�O Wud i0Vd9 '1. XO+m V ro-um r ° °0au�e z o-°n+ViAOw°i°°Wmdnaowu0Q11°Oem sssnd°� mn° m ft4j nm33 LMdn MO N°° n act Xm eN° No:l idndn 30�n0ua 'OY3i1 sl YOCil1N0 NAI'lln310 OM 3An ta=N Vd130 ssnNL 31M i0—e r(zed� ^e S3 uyt� IH-�B, u5y'��u�i� � Llolslnl❑ m�yo q �pp(x�y�q.uap°ui E4a°L° °SNP° �m aowl d91wo �uoued '�loalgol �I � °nM1 N N��odeu eye )m N 0�9 4�9�! 'I 'Jtl;UHBn 31M.M4 and 2MOV'MO aL v A N S d x dH o 3 JdS 0 3 "Ida dS -F °u or dH o m ddS n < m n ldd N dS 'fin o dH �dS n Typlceal Piggy-b;RC:;k ED�EB�tc-lol FOE'pt'l IMUM GRADE OF LUMBER Chcni2x4 SYP /2 or belbr Chad 7x4 SYP /2, or b�llor Webs 2x4 SYP %7 or b'Mar RUM TO SEALED DESIGN FOR DASHED PLATES 7SPPACEµppWaVRwx voffWAS AT 4' OC MAIL I�SgPNSOE ORBEDEOMBRpYM(RIOA7EDNAE RTHMITE ES MUST BEpST�AOOERRD SO THAT ONE SPLICE W1Y BCE APR® NWFAIH THE i0P p10EDRD OF bOP�PdRrPD7O0�&S. RUM TO MUCEER SEALED DESIGN FOR REOMHED PURLDL SPAGNO. TEtl9��O"M IS A'PUCA9LE FOR THE FOLLOMO WM CONDMORS! ynr—MPH WPM 30' NEAR NW. ASCE 7.10 CLOSED BLDO. LOCAED ANYWHERE IN ROOF, 1 MI. FROM COW CAT 140 L, qW op� O DW EPap, V61NO no bl . PSF EDi, 0 69 Psn V� B �RVROOF FRONT FADE_ (%j MAY BE OFFSET FROM BACK FACE PLAIDS AS wnu A9 OM FACES ARE SPACED 4' 00 MAx. DPDOWL WEB BRACING CHART WEB LENGTH REQUIRED BRACING 0' TO 7'9' NO BRACING lx4 'r BRACE. SAME ORAOE SSPKbl" AS WOO 7'9" TO 10' MEMBER, OR BETTER AND BOr" LENGTH OF WEB MEMBER. ATTACH WITH Bd NAILS AT 4" 0/C. 2x4 'I" BRACE. SAME GRADE. SPECIES AS WEB 10' TO 14' GP9W'IlS AT " 0%CE MEMBBER ATTACH WWRH 108 2' JOINT SPANS UP TO TYPE 30' 34' 38' 1 52' A 20 2.50 2.50 3x5 B 4x6 5x6 5x6 5x6 C 1.5x3 1.5x4 1.5x4 1.5x4. D 5x4' 5x5 5x5 5x6 '-14C -Ie�G I Jul ' -a c i I c II C. 101 II *ATTACH PIGGYBACK WITH B'xaxl/2" COX PLTW000 WITH "GO TIAILy Hv CAUn MLnn rtwL yr v—v v.C. MAX. Fo V V cal r Duff bndnl b mt NE ramffi d Inw dalg SW hn r*Wd � F0100 E raala YOYBW � Uftft If am akh 4 .dfar no and dp*ft dNNg w0m od Fmnmd-bimkF 11 C Maximun Loading 55psf at 1.33 Duration Factor 50pof at 1.25 Duration Factor 47pat at 1.15 Duration Factor ern ambg� I l SPACING AT 24" O.C. SCAB -BRACE -DETAIL I ST - SCAB -BRACE Note: Scab -Bracing to be used when continuous lateral bracing at midpoint (or T-Brace) is Impractical. Scab must cover full length of web +P V. THIS DETAIL IS NOTAPLICABLE WHEN BRACING IS — REQINREDAT'113•POINFS OR PBRACE IS -SPECIFIED.' APPLY 2x SCAB TO ONE FACE OF WEB WITH 2 ROWS OF 10d (3° X 0.131-1 NAILS SPACED B"O.C. SCAB MUST BE THE SAME GRADE, SIZE AND SPECIES (OR BETTER) AS THE WEB. �\ MAXIMUM WEB AXIAL FORCE = 2500 Ibs MAXIMUM WEB LENGTH=•12'-0' SCAB BRACE 2x4MINIMUM WEB -SIZE- MINIMUM WEB GRADE OF93 NaHs� � Section Deta➢ ®E Scab -Brace Web Scab -Brace must be same species grade (or better) as web member. L-BRACE DETAIL Nailing Patter . L-Brace s¢e Nail S¢e INaSpedng 1x4 orb I 10d &=o.c. 2x4, 6, or 8 16d 8" o.c. Note: Nail along entire length of L-Brace..' (On Two-FVs Nail to Both Plies)- ,- %W F� Web Note: L-Bracing to be used when continuous lateral bracing Is impractical. L-braca must Cover 90%of web length: L-Brace must be same species grade (or better) as web member.• L-Brace Size for One -Ply Truss Specified Continuous Rows of Lateral Bracing lNeb Size 1 2 2x3 or 2x4 1x4 2x6 1x6 "' 2x8 2x8 "' — DIRECT SUBSTITUTION NOT APLUCABLE. L-Brace Size forTwo-Ply Truss Specified Continuous Rows of Lateral Bracing Web Ste 1 2 2x3 or 2x4 2x4 .» 2x6 2x6 *� 2x8 2x8 "' —DIRECT SUBSTITUTION NOT APUCABLE T-BRACE / 1-13RACE DETAIL Note: T-Bracing / [-Bracing to be used when continuous lateral bracing is impractical- T-Brace / I -Brace must cover 90% of web length. Note: This detail NOT to be used to cD*ert T-Brace / I- Brace webs to continuous lateral braced webs. NailingPatteln T-Brace size Nall Size Nar1Spacing 1x4 or US 10d 8" o.c. 2x4 or 2x6 or 2x8 16d 8" o.c. Note: Nail along entire length -of :T--Brace / I -Brace. (On Two-Ply's Nail to Both Plies) .: ' ' alternate position WEB Nails j Section Detall G T-Brace Web altemate position Naps Web Nails I -Brace SPACING Brace Size for One -Ply Truss Specified Continuous Rows of Lateral Bracing , Web Sim 1 1 2- 2x6 w 2x4 1 x4 (7 T-Brace 1x4 (ry I -Brace 2x6 1x6 (') T-Brace 2x6 I -Brace 2x8 2x8 T-Brace I 2z8 I -Brace Brace Size for Two -Ply Truss Specified Continuous Rows of lateral Bracing Web Size 1 2 2xd or 2x4 2x4 T-Brace 2x4 I -Brace 2x6 2x6 T-Brace 2x6 I -Brace 2x8 12xB T-Brace 2x8 I -Brace i Brace / I -Brace must be same species and grade (or better) as web member. (7 NOTE: If SP webs are used In the tmsrh 1x4 or 1x6 SP braces must be stress rated boards with design values that are equal to (or better) the truss web design values. For SP truss lumber grades up to #2 with 1X bracing material, use IND 45 for T-Bracell-Brat For SP truss lumber grades up to #1 with 1X_ bracing material, use IND 55 for T-Brace ll Brac job iruss I ruse iypo Fl y pM17y2 1772-A Al Common B 1 Jab Reference o-tional Southern Tmss, Fl Pierce, FL, 34351 fl.=114 in I$ 3x5 = 3A = 3x6 = 3x8 = 3x6 = 314 = 3x5 = 1-0-0 11.2-0 l 21-0-0 l 30-10-0 F 41-0-0 42_-00 I 10-2-0 310-0 9-10-0 10-2-0 Plate Offsets (X YI- M:03-10 0-3-01 [11:03-10 0301 LOADING(." SPACING. 2-0-0 CSL DEFL in goc) Well Ud PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TC 0.55 Veri(LL) -027 11-12 >999 240 LIT20 2441190 TCDL 7.0 Lumber.DOL 1.25 BC 0.92 Ven(GT) -0.5911-12 >840 180 13CLL 0.0 Rep Stress Ina YES WB 0.53 Horz(CT) 0.15 11 Na n/a BCDL 10.0 Code FBC2017rrP12014 Maldx-S Weght 2191b FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP M 31 `Except- B2: 2x4 SP No.2 ' WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No.2 3-7-1. Right 2x6 SP No.2 3-7-1 REACTIONS. (size) 1=0-8-0 (min. 0-1-8), 11=030 (min. 0-1-8) Max Horz1=159(LC 10) Max UpliRt=-529(LC 8), 11�529(LC 9) Max Gmv1=1529(LC 1), 11=1529(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied or 2-10-15 oo purrins. — - BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. WEBS 1 Row at midpt 7-14.5-14 FORCES. (Ib) - Max. CompJMax. Ten. -AII forces 250 (Ib) or less except when shown. TOP CHORD 1-2-3211H112, 23=313511127, 3-4-29111962, 45=2844AS3, 5-6=2058r735, 6-7=20581735, 75=-28441983, 8-9=29111963, 9-10=.3135r1127,10-11=3211H 113 BOT CHORD 1-16=11062893,15.16-78312402,14.15=783t2402,13-14=62412402, 12.13=62412402,11-12=9472893 WEBS 6-14=35611195, 7-14=7801462, 7-12-1161656, 9-12-3561345, 6.14-7801462, 5-16=1161556, 3-16=35MO NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-secend gust) Vasd=124mph; TCDL=4.2psh, BCDL=5.Cpsg h=15$ Cat 11; Exp C; End., GCpi=0A8; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) This truss has been designed for a 10.0 psf bottom chord live lead nonconcunent with any other live loads. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except (It--Ib)1=529, 11=529. LOAD CASE(S) Standard Dead Load Deft. = 114 in 3x6 = 2x6 II Us = 3,5 = 3x4 = 3x = 3,41 9z6 = 3c4 = 3x5 = LOADING(pst) SPACING- 2-0-0 C51. DEFL in Quo) Well Lid PLATES GRIP % MO 244/190 TCLL 20.0 Plate Grip DOL 1.25 TO 0.94 Vert(LL) -0.28 13-14 >999 240 TCDL 7.0 Lumber DOL 1.25 BC 0.91 Vert(CT) -0.60 13-14 >831 180 BCLL 0.0 Rep Stress Inor YES WB 0.45 Horz(GT) 0.15 13 n1a n1a Weight 218 lb FT = 20% BCDL 10.0 Code FBC2017[rP12014 MatrixS LUMBER- TOP CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc puriins. BOT CHORD 2x4 SP M 31 *Except* BOT CHORD Rigid ceiling directly applied or 6-9-1 oc bracing. B2: 2x4 SP No.2 WEBS 1 Row at midpt 9-16, S16 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No.2 3-7-1. Right 2x6 SP No.2 3-7-1 REACTIONS. (size) 1=0-8-0 (min. 0-1S),13=0-e-0 (min.0-1S) MaxHorz1=152(LC 8) Max-Up18U=521(LC 8),13=-521(LC 9) Max Grav 1=1 529(LC 1), 13=1529(LC 1) FORCES. (1b) - Max CompJMax Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1.Z- 3215H095, 2-3=309511110, 3-0=29091942, 4-5=28391962, 5-6=20661710, 8-9=20661710, 9-10=28391963, 10-11=29091942, 11-12=3095N111,12-13=321511096, 6-7= 18461683, 7-8=18461683 BOT CHORD 1-18=-108412898,17-18=75312394,16-17=75312394,15-16-60112394, 14-15=60112394,13-14=93=898 WEBS 7-16=331I1148, 9-16=7531442, 9-14=1211561,11-14=3631352, 5-16=7531442, 5-18=-1201561, 3.18=36=52 NOTES- 1) Unbalanced mod live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0ps ,, h=15ft; Cat 11; Exp C; End., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5) Pmvide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=1b)1=521. 13=521. LOAD CASE(S) Standard \0\M l l li//I/ PE -051 r I STATE`OF r _ i0`�,p�-t-1S ilV� T ORIDP: Qi ///1//� js ONq j IENG? \\\ i e Dead Load DeIL -114 in 5X7 = 5.00 12 5x5 — 3X5= 30= 4x6= 3X4= 3x3= 4xe= om= 35= 1i 42d �ola+o sbu aoo aw a4a t-0o LOADING(psf) SPACING- 2.0-0 CSL DEFL in poc) Wall Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.69 Ved(LL) -0.21 16 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.68 Vert(CT) -0.4516-18 >999 180 BCLL 0.0 Rep Stress Ina YES WB 0.77 Horz(CT) 0.15 12 Na nla BCDL 10.0 Code FBC2017?PI2014 MabixS Weight 2301b FT = 20% LUMBER - TOP CHORD 2x4 SP No.2 SOT CHORD 2x4 SP M 31 *Except' B2:2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No.2 3-0-9, Right 2x6 SP No.2 3-0-9 REACTIONS. (size) 1=048-0 (min. 0-1-8), 12=0-8-0 (min. 0-1-8) Max Horz1=137(LC 8) Max Upl'drI=-504(LC 8), 12=504(LC 9) Max Gmvl=1529(LC 1), 12=1529(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied or 3-0-1 cc pudins. BOT CHORD Rigid ceiling directly applied or 6-7-11 cc bracing. WEBS 1 Row at midpl 6-15 FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-3257N067, 2-3= 315311080, 3-4=30141950, 4-5=2955/960, 5-6=-23031755, 6-7=20767732, 75=2300755, 8-9=29541980, 9-10=30141950, 10-11=J75311081, 11-12=3257/1067 BOT CHORD 1-18=10502935,17-18=78612555, 16-17=7S812555, 1Si6=-094/2075, 14-15=6492555, 13-14=-649/2555,12-13=.914R935 WEBS 3-18=274287, 578=-87/467, 5-16= 6531391, &16=190/560, 7-05=138/558, 8-15=6521391, 8-13=87/466, 10-13=274/287 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=151t Cat II; Exp C; End., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate gdp DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcumerd with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except at--lb)1=504, 12=504. LOAD CASE(S) Standard \�\\\kM 11////// PE 051 r t -P STA OF 7 _ 0 5.00 12 M= 2x4 II 5x5 = Dead Load Defi. - 5/161n 3x5 = 12 Us 11 3x4 = Us — 3x8 = 3's = 3x4 = 6x8 11 2100 3D-10-0 41-0-0 I¢ M 9-10-0 410-0 10-2-0 Plate Offsets (C Y)— (1.0-0-10 Edgel M-0-0.121 1 101 [9'.0-0-10 Edoel 19.0-0-121-1-101 LOADING(psf) TCLL 20.0 TCDL 7.0 BCLL 0.0 BCDL 10.0 SPACING- 2-0-0 Plate Grip DOL 1.25 Lumber DOL 1.25 Rep Stress Incr YES Code FBC20177rP)2014 CSI. TC 0.84 BC 0.86 WB 0.35 MatrixS DEFL Vert(LL) Ved(CT) Horz(CT) In -0.31 -0.66 0.14 Coo) 9-10 9-10 9 Odefi >999 >746 nla L/d 240 180 nta PLATES GRIP W20 2441190 Weight 205 lb Fr=20% LUMBER - TOP CHORD 2x4 SP M 31 *Except* T3: 2x4 SP NO2 BOT CHORD 2x4 SP M 31 •ExcepC B2:2x4 SP No.2 WEBS 2x4 SP No.3 WEDGE Left: 2x6 SP No.2, Right 2x6 SP No.2 REACTIONS. (sae) 1=045-0 (min. 0-1-8), 9=0-8.0 (min. 0-1-8) Max Holz 1=122(LC 8) Max Uplih1=485(LC 8). 9=485(LC 9) Max Grav1=1529(LC 1). 9=1529(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied or 3.7-10 cc pudlns. BOT CHORD Rigid ceiling directly appfied or 7-7-10 cc bracing. FORCES. (Ib)- Max. Comp./Max Ten. -Ali forces 250 Qb) or less except when shown. TOP CHORD 1-2=3223N015, 23=2943/915, 3.4=2849/937, 4-5=2389/873, 5.6=-2389/873, 6.7=-28491937, 7-8=2943I915, 8-9=3223/1016 BOT CHORD 1-14>965P2906,13.14=-588/2224, 12-13=-SB6/2224, 11-12=584/2224,10.11=584/2224, 9-10---844/2906 WEBS 2-14=-4331420, 4-14=261/699, 4-12-89/444, 5-12=285/2l 1, 6-12=89/444, 6.10=2611699, 8.1G= 433I420 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=160mph (3second gust) Vesd=124mph; TCDL=4.2psf, BCDL=S.Dpsf; h=15fk Cat 11; Fxp C; End., GCpI=0A0; MWFRS (envelope); cantilever left and dght exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10,0 psi bottom chord live load nonconwment vdth any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b upOft atjeint(s) except at=lb)1=485, 9--485. LOAD CASE(S) Standard job Truss iruss lype fir Plan IM 1772A A5 HP 2 1 Job Reference Lopgono Southern Truss, FL Piece, FL. 3 Sbl .: .wa w�, a,ermu o<.—. ��ie nu,a,,,� , ID:EePCUIwCWA016WS07vTFdz?5cKKRojgzvOPO DuhBxjl4E?acm62vzg.Dlo 7.2-2 148a 21." 2800 34-E-2 42-0-0 7.2-2 8 .14 7-0-0 7-0-0 6A-2 7.1.1 5x7 = 2x4 11 5x7 = Dead Load Dell. -114 in 3x5 = 2x4 It Cuts = 3xs = 5x5 = 2x4 11 3x5 = 1i 4T-0U 1 7-2-2 t40a 17-- 28ba 34-a3 6-1P2 8-914 7-0a 7-W a6R Al6-11-1 Plate Offsets (X YI- 11.0310 0301 r4:DS40-2-121 MDS-4 I-2.121 (90310 0-3-0] 111.0-2$ 0341 [MD-2.8 0.3A1 LOADING04 SPACING- 240-0 CSL DEFL in Qoc) Udell Lrd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.95 Verl(LL) 0.27 12 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.80 Vert(CT) -0A811-12 >999 190 BCLL 0.0 Rep Stress Ina YES WB 0.67 Horz(CT) 0.19 9 We n/a BCDL 10.0 Code FBC2017rrP12014 MatrixS Weight 225 lb FT=20°% LUMBER - TOP CHORD 2x4 SP No.2 *Except T1: 2x4 SP M 31 BOT CHORD 2x4 SP No.2 ' WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No23-5-8•Right 2x6 SP No.23-6.7 REACTIONS. (size) 1=0-8-0 (min. 0-1-13), 9=0-8-0 (min. 0-1-13) Max Hoa 1=107(LC 8) Max UpliM=485(LC 5), 9=-065(LC 4) Max Grav1=1529(LC 1). 9=1529(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid ceiling directly applied or 6-2-11 oc bracing. FORCES. (lb) - Max CompJMax Ten. - All forces 250 (lb) or less except when shown. TOP CHORD 1-2=328211015, 2J=-0164N030, 3-4=2684/938, 4S=2743/1053, 55=-2743/1053, 6.7=2681/939, 7b=a153/1029, 8-9=3274/1013 BOT CHORD 1-14=8.4412956,13-14=89412956,12-13=-6952419,11-12=69012418, 1041=877r2949, 9-10=-87712949 WEBS 3-14=Or285,3-13=-607/372,4-13=-82/449,4-12- 197/575, 5.12=-4221321, 6-12=-1971578, 6-11-86/450, 7-11=-6031368, 7-10=0/285 NOTES. 1) Unbalanced toot live loads have been considered forthis design. 2) Wind: ASCE 7-10; Vult=160mph (3second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0ps% h=15ft; Cat II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcument with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of vrimstanding 100 lb uplift atjoint(s) except (It-ib)1=465, 9=465. LOAD CASE(S) Standard PE 051 r �t STAT)=`OF i17 tz S 0NAi,ENG\\�� �5 5x5 = 3,4 = 3x6 = 3,4 = bx5 = Dead Load Deff. - 6116 In 3x5 = 2x4 II 31S = 4xa = axa = r. — 3,2 = 2x4 II 315 = 1 40 d 42-00 1 6314 12Ae 2141e 3aa-0 958-3 690 4 411-id 9-0a 9-0-0 2 411-14 1-60 Plate Offsets (X,YI— T1.0310 0301 r1 0-2 2 Edoel 111.043.10 0 3. , I1144-7 Edeel LOADING(psf) SPACING- 2-0-0 CSI. DEFL in Qoc) 0defl Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.67 Vert(LL) 0.31 15 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.82 Vert(CT) -0.6715-17 >868 180 BCLL 0.0 Rep Stress Ina YES WB 3.88 H=(CT) 0.19 11 nfa We BCDL 10.0 Code FBC2017frP12014 Matrix-S Weight 220 lb FT=20% LUMBER - TOP CHORD 2x4 SP NO2 BOT CHORD 2x4 SP No.2'Except' B2: 2x4 SP M 31 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No.22-11-15, Right 2x6 SP No.22-11-15 BRACING - TOP CHORD Structural wood sheathing directly applied or 2-7-0 cc puriins. BOT CHORD Rigid wiring directly applied or 5-9-10 o , bracing. REACTIONS. (size) 1=0-8-0 (min. 0-1-13),11=048-0 (mN.0.1-13) Max Hom 1=92(LC B) Max Uplift1=-491(LC 5), ll=-491(LC 4) Max Gmv1=1529(LC 1), 11=1529(LC 1) FORCES. Qb) - Max. Comp.IMax. Ten. -All forces 250 Qb) or less except when shown. TOP CHORD 1-2=329911082, 2-3=319511097, 3-0=284411030, 45=25931991, 5-6=-314311200, 6-7=-314311200, 7-8=-25931991, 8-9=284411030, 9-10=319511097,10.11=329911082 BOT CHORD 1-18=94812972,17-18=948I2972,16-17=104813087,15-16=1048P3087, 14-15=1047/3087,13-14=-104713087, 12-13=-94W972,11-12=945@972 WEBS 3-17=-4501305, 4.17=2041165, 5.17=7651320, 7-13=-7651320, 8-13=204f765, 9-13=-4501306 NOTES- 1) Unbalanced mof rive loads have been considered for this design. 2) Wind: ASCE 7-10; VuR=160mph (3-second gust) Vasd=124mph; TCDL=1.2psF BCDL=5.Opsf; h=15ft; Cat. II; Exp C; End., GCpi=0.16; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) except Qt=lb)1=491, 11=491. LOAD CASE(S) Standard PE 051 ' r I �0�� �� 1-019 OR)DP.��i�� AL A �;10 ENG\\\��� a ` rUSe Iruss lype Y Plan 722 1772-A A7 Nip 1 Job Reference o tlonal SOW,em rasa, L Plena, PL, 34951 RW:8330s OG 212018Print8.230serd212D18MDeklndusV1m1 c Wed Nov 14 16::1522e18 P at ID:EePOUIwCVNA016wS07VTFdz75cK-GDwUFfxhxd76BJdv3ADwJJmZgXz5XseUEOXOdYyDkF sae B3-id 12-0a 1 18-00 17 2d-0e 3a00 M 42-0-0 631d 5-0.2 14-0 2-Ba 1+D ee-0 662 83-id OS-D 4x6 G 2 Dead Load Deb. = 5fi6ln 5x5 = 11 3x4 12 13 d 14 19 18 17 5X7 = 21 20 16 15 5x7 = 3x5 = 2x4 11 3x8 = 46 = 3x4 = 416 = 3x8 = 2x4 11 3X5 = 14-0 9Y�D 1 6a-1d 12-0-0 2t-0-0 3D0a 3682 dd d-t -14 z 9-0-0 90o saz d-tt-aBD 14 t� 34 = 6x5 = 6x84 3XB= 6 3x4 = Us — 5.0012 5 2 7 8 9 3x4 G 3x4 = Plate Offsets (X.YF- f 1.0310 0.231 It •D-2-6 Edger 14:0.2-12 Edeel 15'0-3-0 0.2-01 16'113M D-2.41 P•0-0-3 0-3-47 114.1-0-7 Edae] 114:0310 D3-01 LOADING(psf) SPACING- 2-0-0 CSL DEFL in (roc) Odell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 Vert(LL) 0.30 18 >999 240 MT20 244/190 TCDL 7.0 - Lumber DOL 1.25 BC 0.82 Ven(CT) -0.5716.18 >869 180 SCLL 0.0 Rep Stress Ina YES WB 0.89 Hom(CT) 0.19 14 We nla BCDL 10.0 Cade FBC2017r P12014 MatrixS Weight 229 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP N0.2 `Except' TOP CHORD T2,T4:2x4 SP No.3 BOT CHORD 2x4 SP No.2'Except' SOT CHORD B2: 2x4 SP M 31 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP N0.2 2-11-15, Right 2x6 SP No.2 2-11.15 REACTIONS. (size) 1=0-8-0 (min. 0-1-13),14=D-M (min. 0-1-13) Max Harz 1=102(LC 9) Max UpliR1=-469(LC 5), 14=579(LC 9) Max Grav1=1529(LC 1), 14=1529(LC 1) FORCES. Ph)- Max. Comp./Max. Ten. -All forces 250 (Ib) cr less except when shaven. TOP CHORD 1.2=330711032, 23=320311047, 34=28881986, 4-7=23491813, 7-8=25971942, 8-9=313811165, 9-'I0=3138/1155, 10.11=259311056,11-12--2844A088, 12-13=-319511238,13-14=329911224,4-5=-2821166,6-7=2881159, 5-6=-2601154 BOT CHORD 1-21=904PL981, 20.21=90412981, 19.20=98213073,18.19=98213073, 17-18=1008/3091, 16-17=100813091, 15-16=1059/2972,14-15=105912972 WEBS 3.20--4671291, 4-20=-208f727, 8-20=7661362,10.16=658/306, 11-16=1961769, 12-16=-053/284 Structural wood sheathing directly applied or 2-2-0 oc pudins. Except 1 Row at midpt 4-7 Rigid ceiling directly applied or 5-8-12 ce bracing. NOTES- 1) Unbalanced roof five loads have been considered for this design. 2) Wind: ASCE 7A 0; VuR=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh, BCDL=5.OpA h=15ft; Cat II; Exp C; End., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b uprdt atjoint(s) except Gt=lb)1=469, 14=579. 6) Graphical pudin representation does not depict the size or the orientation of the puriln along the top and/or bottom chord. LOAD CASE(S) Standard MI BC \\P ---- PE 051 r 1 STA OF 7 �� i0`� ORIDP �Q �\ Job N5a N66 ypa en IM I7772-A AB HIP 1 1 Job Reference (optioneft southern cuss, Ft. Pierce, FL., 34961 n6m. o.d o.23a 17Qx1 2aCIEg k TFNp h W tl 14 dj7pnn 2018 P pa kn ID:EaPOUhvCWA016'w307vTFdz75cK-CC1EgLyxTFNpNdmIBbFOOksvBKdl7pnnhkOfiiQyJJ�D 5�-14 tooa 11d8 17de T 18Ao 2a7-7 92-0-0 364Lx i /2-0-0 �- sau � aax fwa sas 1�1�1 TJ8 482 sa-i7--' 3x6 = 3x6 = 7x8 2x4 11 7 Sx5- 3x6= 5.00 12 S Td TLc _ "� 8 9 3x4 =10 Sx7 = Dead Load Dell. = 6116 in Man 13 pmo:ou� wAl M 5x7 = 20 19 18 I7 16 15 Sx7 = 3,5 = 3x4 = 4xe = 318 = 3x4 - 4x6 = 3x4 = 3x5 = 42-0 +0 1 1pe0 11he 2aT-T 328E 40 -0 7<9 ab41 4 eaa T-a9 T-b13 i-0L 04 Plate Ogsets (X Yl- 11 03.10 0 231 I4 0.2 12 Edael IS 03-D 0-2�1 fT03-0 0.2�11 B•0-03 0-3-4] 111.0.5-40.2-61 114.0.3-10 0301 118:0-2-8;0-1.81 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) Well Lid 240 PLATES GRIP MT20 2441190 TCLL 20.0 Plate Grip DOL 1.25 TC 0.78 vert(LL) 0.3517-18 >999 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.6317-18 >793 160 BCLL 0.0 Rep Stress lnrt YES WB 0.65 Horz(CT) OAT 14 We Na Weight2281b FT=20% BCDL 10.0 Code FBC2017RP12014 MatrixS LUMBER- BRACING - TOP CHORD 2x4 SP No.2 *Except* TOP CHORD T3,T5: 2x4 SP M 31, T2: 2x4 SP N0.3 BOT CHORD 2x4 SP M 31 'Except' BOT CHORD B2: 2x4 SP No 9 WEBS WEBS 2x4 SP No.3 SLIDER Left 2x6 SP N0.2 252. Right 2x6 SP No.2 2-5.2 REACTIONS. (size) 1=0.8-0 (min. 0-1-8), 14=0.8-0 (min. 0-1-8) Max Horz1=-87(LC 9) Max Upll tl=-094(LC 6). 14=566(LC 9) Max Grev1=1529(LC 1), 14=1529(LC 1) FORCES. (to) - Max. Comp.IMax. Ten. -All forces 250 Qb) or less except when shown. TOP CHORD 1-2=-3284/1149, 23=3227/1156, 3-4=-306811069, 4-6=S05511027, 6.8=4105511027, 8.9=-362311368,9-10=-362311368,10-11=373111455,11-12=301611100, 12-13=3214/1264,13-14=326711253, 4-5=-6061384, 73=6151385, 5-7=-568f362 BOT CHORD 1-20=1g0812954,19.20=-87612797,18.19=87612797, 17-18=130413731, 16-17=873(2751, 15.16=-873/2751, 14.15=1a892939 WEBS 3-20=259278, 4-20=161361, 4.18= 42811085, 6-18=3021220, 10.17= 4251313, 11-17=496/1128,11-15=-91385, 12-15=2241259 Structural wood sheathing directly applied or 2-7.4 oc pudin. Except 1 Raw at mldpt 4-8 Rigid ceiling directly applied or 2-2-0 oc bracing. 1 Row at midpt 10-18 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psf BCDL=5.0psh h=15ft; Cat II; Exp C; Encl., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This lass has been designed for a 10.0 psf bottom chord live load nonconcunent with my other live loads. 5) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100 Ill uplift at joint(s) except Qt=lb)1=494. 14=566. 6) Graphical pudin representation does not depict the size or the orientation of the pudin along the top and/or bottom chord. LOAD CASE(S) Standard ou Truss Nee ype Pan 17M 1772-A Asa Rod spedal 6btler 1 1 _"__ _'_•__._.-_�........,_..�.. Job Reference o tional .,�..e.,,._,. ,_.......... ,_., w..,r.,.....e.a.ne.nc emn m,.er U Mere IN59, YL YIPJW, YL., Jatlll Dead Load Deg. =12 in 6x8 MT20HS= 6x12 MT20HS= 5.0012 4 7x6= 7x8MMOHS- SxB MTZOHS= 5 6 2M 11 3x12= 2x4 7 21 22 8 23 T, 24 9 25- 10 2x4 • 4x8 i 11 4Ao 1r 12 H 1 13 ' P} Sx9 - 20 1S 18 26 27 1728 16 1rig 30 14 6x12 = o 3x7 = 314 = 7x16 MT20HS= 5x7 = Us = 2x4 II 3,9 = Us = 5xl2 MT20HS WB= 7-10.7 144F0 200-0 1 25.7.4 298.12 34-0-0 41-0-0 6-10.7 841-0 1-4- 434 4-1-e 43d 7-0-0 Plate Offsets (x.Y)- (1:0-2-10,0-3-01• [4:03.4,0.1.12], (5:0�-g,036], [7:0.6-O,Edge], (9:03-0,0-1.8]. (1g:Od-0,0-1-13], (13:1-2-2,Edge], (13:0-1-2,0-3.OL (1CU-3.12,0-151, [18 0-1 12 0.15I 119.0 7-4 0-3-01 LOADING(psf) SPACING- 2.0-0 est. DEFL. in Qoc) VdeO L/d PLATES GRIP TCLL 20.0 ' Plate Grip DOL 1.25 TC 0.60 Vert(LL) 0.82 17-18 >607 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.97 Vert(CT)-1.1717-18 >424 180 MT20HS 1871143 BCLL 0.0 Rep Stress [nor NO WB 0.83 Horz(CT) 0.27 13 n1a nla BCDL 110.0 Code FBC2017/TPi2014 MatrixS Weighl:235lb FT=20Y LUMBER- BRACING - TOP CHORD 274 SP M 31 'Except- TOP CHORD Structural wood sheathing directly applied or 2-1-9 oc puriins. T2: 2x4 SP No.2, T3: 2x6 SP No.2 BOT CHORD Rigid calling directly applied or 4.2-8 oc bracing. BOT CHORD 2x4 SP M 31 WEBS 1 Row at mldpl 6-19, 9-14 WEBS 2x4 SP No.3 'Except- W3,W6:2x4 SP No.2 OTHERS 2x4 SP No.3 SLIDER Left 2x6 SP No.2 2-10-15, Right 2x6 SP No.21-10-10 REACTIONS. (size) 1=0-8-0 (min. 0-1-10), 13=0-8-0 (min. 0-2-1) - Max Horz1=89(LC 9) Max Uplift1=731(LC 8), 13=1166(LC 9) Max Gmvl=1972(LC 1), 13=2503(LC 1) - FORCES. Qb)-Max. CompJMax.Ten. -All forces 250 Qb) orless exceptwhen shown. TOP CHORD 1-2=4358/1686, 23=4302/1695, 3-4=-419311690, 4-5=-561212445, 5-6=5154/2225, 6-7=-8090/3682, 7-21=735713436, 21-22=735/13436, B-22=7357/3436, i -Tell (a:(101zi] WEBS 4-19=162213590, 5.19=235011103, 6-19=16261805, 9-17=357/929, 9-15=01296. 9-14=1910/976, M. 6.18>162213520. 7-18=278311375 NOTES- 1) Unbalanced met live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3secand gust) Vasd=124mph; TCDL=4.2psf; BCDL-5.Opsf; h=15177: Cat. II; Exp C; End., GCpl=0.16; MWFRS (envelope); can0lever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) All plates are MT20 plates unless otherwise Indicated. 5) This truss has been designed for a 10.0 pat bottom chord live load noncancurrent with any other live loads. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1DO lb uplift at]oint(s) except Qt--I13)1=731, \\ 7) Hanger(s) or other connection devlce(s) shall be provided sufficient to support concentrated load(s) 37 Ito down and 36 tu up at 22 -6C�L�// Ib down end 42 to up at 244-12, 47Ib down and 571b up al 26--12,147 Ib down and 160lb up at 28-4-12,147 lb down and 150 CENS 29.11-4. and 147 to down and 150 lb up at 31-11-4, and 274 lb down and 280 lb up at 34-0-0 on top chord, and 471 Ito down and.Z6 lb up ��F �` at 22.4-12, 19 lb down and 2 Ito up at 24-4-12, 24 lb dawn and 3lb up at 26-4-12, 60 lb down at 284.12, 80 lb down at 29-11 nd B PE �$1 lb down at 31-114. and 285 lb down and 134 lb up at 33-11.4 on bottom chord. The design/selec0on of such connection devil is responsibility of others. t - &NAN %&Q$44FE(S) section, loads applied to the face of the truss are noted as front (F) or bade (B).ZZ p STATEOF 7 i0��.c-1-liS _//�F���ORI_DP•��4�� Gl Jou TMW yp0 Qty Fly Plan 1722 1772-A ASG Rant Special Girder 1 1 Job Reference bona Soulhem TNss, Pierce: FL. 34951 Ra0:a.2Sas IWCVV01aPMt O7vT Oct212-8b9 k1 ealnes.lna Wed9x[T8l18:34:O6 ZVD Paget ID:FaP0U1wCWA01 GxS07vTFdzTScK-Bb9_50_B?sdXtlwwglOHsTex1T81pThU49NDmJyJOk LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=125 Un k. Loads (pit) Vert: 14=54, 4-5=54, 5-6=-54. 6-7=54, 7-10=54, 10-13=.54,1-13=20 Concentrated Loads(Ib) Vert 10=178(F)15=54(fc) 9=107(F)14=285(F) 24=107(F) 25=107(F) 26=-471(F) 29---54(F) 30=54(F) 5x7 = 5.00 RY 4 2x4 II 3x6 = 3x4 = 5ix7 = 6 6 7 3 Dead Lead Deb. - 51161n i MAR U Sx7 = 17 18 15 14 13 12 Sx7 = 3x5 = 3v4 = 48 = 3x8 = 3x4 = 415 = 3x4 — 3x5 LOADING(Psf) SPACING- 2-0-0 CSI. DEFL in Qoc) Udell Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.46 Vert(LL) 0.37 14-15 M9 240 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.94 Vert(CT) -0.64 14-15 1773 180 BCLL 0.0 Rep Stress lncr YES WB 0.66 Horz(CT) 0.17 11 n1a n/a BCDL 10.0 Code FBC2017fFP12014 MatrixS Weight 213 lb FT = 20% LUMBER- BRACING. TOP CHORD 2x4 SP Nm2'Except• TOP CHORD Structural wood sheathing directly applied or 3-0-2 oo puriins. T2,T3: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 2-2-0 oc bracing. SOT CHORD 2x4 SP M 31 •E GW WEBS 1 Row at midpt 7-15 B2: 2x4 SP No.2 WEBS 2x4 SP No.3 SLIDER Left 2x6 SP No.2 25.2. Right 2x6 SP No.2 25-2 REACTIONS. (size) 1=0-8-0 (min. 0-13),11=0-8-0 Max Harz1=76(LC 8) - Msx Uplift1=517(LC 5), 11=517(LC 4) Meat Gmvl=1529(LC 1111=1529(LC 1) FORCES. Qb) -Max. Comp,/Max. Ten. -All forces 250 Qb) or less exceptwhen shown. TOP CHORD 1-2�326511166, 2-3=3212I1201, 3-0=-300811112, 45=371111491, 5-6=-37N/1492, 6-7=371111492, 75=-3710/1491, 8-9= 300811112, 9.10=-321211201, 10.11=3265/1186 BOT CHORD 1-17=104712937,16-17=-9(y7/2754,15.16=907/2754, 14-15--133813710, 13-14=90412754,12-13=-904/2754, 11-12=1044/2937 WEBS 3-17=2171286, 4-17=201384, 445=-50211201, 6-15= 416/314, 7-14=-4601315, B-14=501/1199, 8.12=20/384, 9=12=2161287 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3s nd gust) Vesd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=151t; Cal 11; Exp C; End., GCpt=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water pending. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 th uplift atJoint(s) except Qt=lb)1=517, 11=517. LOAD CASE(S) Standard ����\I11 ENS�`'`�i/ PE O51n� 1 r jk,� f/ � 1 STATE pF i0��.cfe-1-lS SONA i IEX"G?���� O Glider 5.00 F12 Rll m Sx5 = 20 21 19 31 32 3x8 = 3x8 = 3x5 = 3x6 = 522 23 24 25 6 7 26 1817 33 34 35 16 36 37 Us MT20HS= 2x4 II 3x4 = Dead Lead Dell. = 71161n 3x5 = 5x5 = 27 8 29 30 9 2x4 i 10 4x6 11 12 I� 38 1614 39 40 13 6x7 = 3x4 = 3x9 Us 4x8 MT20HS= Plate 08sets (Xl?-fi-03100.3-01 f12'03100301 (13'0340-1.81 f19'0-1-80-1-81 - LOADING(psf) SPACING- 2-0-0 CSI. DEFL. Vert(LL) In (lac) 0.64 16 Well >776 Vd 240 PLATES NMI) GRIP 244/190 TCLL 20.0 TCDL 7.0 Plate Grip DOL 1.25 Lumber DOL 1.25 TC BC 0.92 0.56 Vert(CT) -0.8915-16 >555 180 MT20HS 187/143 BCLL 0.0 Rep Stress Ina NO WB 0.75 Hom(CT) 0.20 12 n/a nla Weight 424 lb FT = 20% BCDL 10.0 Code FBC2017/rP12014 Matrix-S LUMBER - TOP CHORD 20 SP No.2 BOT CHORD 20 SP M 31 WEBS 2x4 SP No.3 ` SLIDER Left 2x6 SP No21-10-10. Right 2x6 SP No.21-10-10 REACTIONS. (size) 1=048-0 (min. 0.1-8),12=0-8.0 (min.0.1-6) Max Horz 1=61(LC 10) Max-Uplift1=1348(LC 5). 12=-1348(LC 4) Max Gmv1=2954(LC 1), 12=2964(LC 1) BRACING - TOP CHORD Structural wood sheathing directly applied. BOT CHORD Rigid calling directly applied or 7-9-12 oc bracing. FORCES. (Ib) - Max. Camp./Mm Ten. - All forces 250 6b) cr less except when shown. TOP CHORD 1-2-660813106, 2.9=-5556/3110, 3-4=-666213184, 4-20--6230/3012, 20-21=623013012, 21-22=-622913012, 5-22=-622913012, S23=9131/4425. 23.24=913114425, 24-25=9131/4425, 6.25=913114425, 6-7=9132f4427, 7-26=9132/4427, 26-27�913214427, 8-27=313214427, 8.28=-623013012, 28.29=-6230/3012, 29-30=623013012,930---623013013,9-10=-666313185, 10-11=-6557I3111, 11-12=660913107 BOT CHORD 1-19=2777/5947,19-31=-430419131, 3132=-030419131,1832=-03D419131, 17-18=-030419131, 1733=-4734/10060, 3334=-0734I10060, 3435=-4734110060, 16-35=4734/10060, 16-36=-4734110060, 36.37=-4734110060, 37-38=-0734I10060, 1638=-4734110060, 14-15=430419132, 1439=-430419132, 39-00=-030419132, 13-40=4304/9132,12-13=277615948 WEBS 3-19=-2111418, 4-19=715/1934, 5.19=3325/1599, 6.17=911877, 6.17=10911488, 6-16=01520, 6-15=1089/486, 8-16=90/876, 8-13=3326/1600, 9.13=71611935, 1D-13=212/418 NOTES- 1) 2-plytruss to be connected together with 10d (0.131W) nails as follows: Top chords connected as follows: 2x4 -1 row at 0-9-0 oc. Bottom chords connected as follows: 2x4 -1 row at 0-9-0 oc. Webs connected as follows: 2x4 -1 mw at D-9-0 oc. 2) All loads are considered equally applied to all piles, except 8 noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply wnneclions have been provided to distribute only loads noted as (F) or (B), unless otherwise Indicated. 3) Unbalanced mof live loads have been considered for this design. 4) Wind: ASCE 7-10; Vult=160mph (3second gust) Vasd=124mph; TCDL=4.2psF BCDL=5.0psf, h=15ft; Cat II; Exp C; End., GCpl--0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 5) Provide adequate drainage to prevent water ponding. 6) A9 plates are MT20 plates unless otherwise Indicated. \\ ��GEMS �� /// 7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. F �` 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001b upliftatloint(s) except Qt=Ib)1�348, PE OS 1 12=1348. Continued on page 2 D 1 STATE F 0 c-l- IN itv� ORIDP�R, //,`SS JOD Iruss Iruss ype plyPlan 1722 l 1772-A A11G Kip Girder 1 2 J b Reference ( ptlona0 Sou "Truss. FL PWM FL, 34ae1 dun: aT3a¢ OG T1201a PdrK B230e0G 212a1a MneK indusuies, inc wad irw i4 l-o:ad:u-n ur-o Peae2 ID:EaPOUIwCWA016wSO7VTFdZ7ScK-ZAr712041nO6u5 Fxis;aMcLOx93XWr01tNe- NOTES- 9) Hanger(s) or other connectiondevlce(s) shall be provided sufficient to support concentrated load(s) 225 lb down and 280 lb up at 840-0,107 lb dovm and 150 lb up at 10-D-12, 107 lb down and 150 lb up at 1240.12,107 lb down and 150 )b up at 14-0-12, 107 lb down and 160 lb up at 16-0-12, 107 lb down and 150 lb up at 18-G-12, 107lb down and 160 lb up at 20-0-12, 107 th dawn and 150 lb up at 21-11-4,107 lb down and 150 lb up at 23-114, 1071b down and 150 lb up at 25-11-4, 107 lb down and 150 lb up at 27-114, 107 lb dawn and 150 lb up at 29-114, and 107 lb down and 150 lb up at 31-114, and 225 lb down and 280 lb up at 34-0-0 on top chord, and 285lb down and 134 lb up at 8-0$ 80 Ib down at 10-0-12, 801b down al 12-0.12, 801b down at 14-0.12, 801b down at 16-0-12, 80lb down at 18-0-12, 80 lb down at 20-0.12, 801b down at 21-114, 801b down st 23-114. 80 lb down at 25-114. 80 lb down at 27-114. 80 lb down at 29-114, and 80 lb down at 31-114. and 2951b down and 134 lb up at 33.114 on bottom chord. The designlselecdon of such connection device(s) is the responsibTity of others. 1) Dead + ROaf LJve (balanced): Lumber Increase=1.25, Plate Incase=1.25 Vert. 14=64, 4-9--54, 9-12--54, 1-12=20 Concentrated Loads Qb) Vert:4=-178(B) 7=107(8) 9=-178(B) 18=1 20=107(B) 21=107(B) 22=107(8) 23=107(B) 24=107(B) 25=107(8) 26=107(B) =54(B) 35=54(8) 36=54(8) 37=64(B) 38=-54(B) 39=WB) 40=-54(8) \w (VlI N/ // 0F� `< PE 051 7 t - TAT OF //,/SS ONA U2 IM 11 32-15 G_" LOADING(psf) SPACING- 2-0-0 CSI. DEFL, in (hoc) Odefi Vd PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.20 Vert(LL) -0.00 4-5 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.19 Vert(CT) 0.00 43 >999 180 BCLL 0.0 ' Rep Stress Ina YES WE 0.05 Horz(CT) -0.02 3 n/a n1a BCDL 10.0 Code FBC2017frP12014 Matrix-P Weight 13 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Sbuctural wood sheathing directly applied or 3-11-5 no pudins. BOT CHORD 2x4 SP No2 BOT CHORD Rigid ceiling directly applied or 10-0-0 no bracing. WEBS 2x4 SP No.3 REACTIONS. (size) 3--Mechanical, 4=1viechanical, 5=1-11-6 (min. 0-1-8) Manx Hmz5=58(LC 4) Max Uplift3=-32(LC 11), 4=-39(LC 1). 5=254(LC 4) Max Gmv3=20(LC 17), 4=48(LC 17), 5=346(LC 1) FORCES. gb) - Max. Comp.IMax. Ten. -All forces 250 (lb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vult-160mph (3-second gust) Vasd=124mph; TCDL=4.2psh BCDL=5.0pst h=15ft; Cat. II; Exp C; End., GCPI=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 pad bottom chord live load nonconcurtent with any other live loads. 3) Refer to girder(s) for truss to buss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) 3, 4 except at--Ab) 5=254. 5) Hanger(s) or other connection device(s) shall be provided suffident to support concentrated load(s) 28 lb down and 45 lb up at 2-11-0 on top chord. The design/selection of such connection devices) Is the responsibility of others. 6) In the LOAD CASE(S) section, toads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead+ Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pit) Vert 1-3=-54, 1-0=20 Flip Mer MrM 1�-70 1-10� -- 11-2-4 1-0-10 IOSI01 4-6-46-4-8 44 I 4-9-12 Plate Offsets My)— 12:D-0-8 0-1 12) [ :0-1.61 7-81 180-0-0 0-1-121 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in Poe) Vdefl Lld PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.58 Ved(LL) 0.06 6.7 >999 240 MT20 244h90 TCDL 7.0 Lumber DOL 1.25 BC 0.76 Vert(CT) I -0.11 6-7 >984 180 I BCLL 0.0 Rep Stress Ina NO WB 0.24 Horz(CT) -0.04 4 rda me BCDL 10.0 Code FBC2017frP12014 Mabbk4i Weight 441b FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP Nc.2 TOP CHORD Structural wood sheathing direcily applied or 6-" cc pudins. BOT CHORD 2x4 SP No2 BOT CHORD Rigid ceiling directly applied or 9-10-2 oc bracing. WEBS 2x4 SP No.3 ' REACTIONS. (size) 4=Mechanical, 8=0-11.5 (min. 0-1-8), 6=Mechanical Max Horz8=164(LC 20) Max Uplift4=-125(LC 4). 8=357(LC 4), 6=117(LC 8) Max Gmv4=147(LC 1). 8=441(LC 31), 6--259(LC 1) FORCES. (Ib) - Max. Comp./Max. Ten. - Al forces 250 Go) or less except when shown. TOP CHORD 1-2---4301236, 2-9=4971270, 9-10=-4811269, 3-10=-4351254 BOT CHORD 1-8=2221434, 8-12---3421434, f 2-13=-3421434, 7-13=342(434, 7-14=3421434, 6-14=-3420434 WEBS 2-8=3531186,3-6=-4691369 NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.0pst h=15ft; Cat II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cerrulever left and right exposed; Lumber DOL=1.60.plate grip DOL=1.60 2) This truss is not designed to support a ceiling and is not intended for use where aesthetics are a consideration. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcunem with any other live loads. 4) Refer to girder(s) for truss to truss connections. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 to uplift at)oint(s) except at -lb) 4=125, 8=357,6=117. 6) Hanger(s) or other connection device(s) shall be provided su0ldent to support concentrated load(s) 29 to down and 43 lb up at 2-11-0, 29 lb down and 43111 up at 2-11-0, 39 lb down and 63 lb up at 5-8.15, 26 lb down and 52 lb up at 5-8-15, and 64It dovm and 113 lb up at 8-6-14, and 58 lb down and 107 lb up at 8-6-14 on top chord, and 70 lb down and 158 lb up at 2-11-0, 70 Ib down and 158 @ up at 2-11-0, 12 lb down and 2lb up at 5-8-15, 10 lb down and 2lb up at 5.8-15, and 33 to down at 8-6-14, and 27 lb down at 8-6-14 on bottom chord. The designfseledon of such connection devices) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the Wss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead +Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (plf) Vert: 1-0=34, 1-5=20 Concentrated Loads Qb) Vert: l l=-76(F=-44, B=33)12=155(F=77, B=77)14=48(F=29, B=19) PE 051 1 1 STA OF �O ��`.<0R1DP ���� =life in O . cuss iruss type PIBn 1722 17M-A HV6 Valley 1 f dab Reference o tional souurem ruse. FtPleme,FL. sassl RMjD:EEaaPODUI ZWCWA016wS0v7TFdn5CK-ZWFLr43ybn4iOhLiOgIHUrJQB 1ReZVIm9 YPrysJDld 5-168 fi4-0 5.10-8 zxa u ZA G 1x4 It P%{,III LOADING(psf) SPACING- 2-0-0 CSL DEFL. In Qoc) Wall Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.18 Vert(LL) No - Na 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 SC 0.13 Vert(CT) Na - Na 999 BCLL 0.0 Rep Stress Ina YES WB 0.05 Horz(CT) 0.00 Na Na BCDL 10.0 Code FBC2017/TPI2014 Matr&-P Weight 23lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.3 TOP CHORD BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 BOT CHORD OTHERS 2x4 SP No.3 REACTIONS. (size) 1=6-4-0 (min. 0-1-8), 4=64-0 (min. 0-1-8).5=64-0 (min. 0-1-8) Max Hmz1=112(LC 8) Max Uptift4=-47(LC 8). 5=136(LC 8) Max Grevt=61(LC 1), 4=88(LC 1), 5=255(LC 1) FORCES. (lb)- Max. CompJMax. Ten. - All forces 250 (Ib) or lass except when shown. Structural wood sheathing directly applied or 6-G-0 no pudins, except end veNcals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=1.2psF, BCDL=S.Opst; h=15fk Cat 11; Exp C; Encl.. GCpl=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load noncencunent with any other live loads. 4) Provide mechanical connection (by others) of truss to beating plate capable of withstanding 100 lb uplift at Joints) 4 except Qt=Ib) 5=136. LOAD CASE(S) Standard PE i I STA 051 OF ORIDP •��i �� a mss cuss ype P n 1722 1772-A J2 Jack -Open 11 1 Job Reference o 'onal anntl,eln TN68. FL PI01Ce. YL.51YY1 n 11; u . —I uu,o 1,m1 ua —_. -.....................o...=.... ............� ....�... a . ID:EaPOUIwCWA016wSD7vTFdz75cK-zlWFL43ybiOhLrOgFHOGjOeTVZYXtbxzXzyY ryJDkf 2-0-0 2.0-0 143-0 04-0 LOADING(psf) SPACING 240-0 CSI. DEFL. In Qoc) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TO 0.06 Vert(LL) JIM 4 >999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.18 Vert(Cr) 0.00 4 >999 180 BCLL 0.0 Rep Stress Ina YES WS 0.00 Horz(CT) -0.01 2 rda We BCDL 10.0 Code FBC2017rrP12014 Matrix-P Weight: 6lb FT=20% LUMBER - TOP CHORD 2x4 SP No.2 BOT CHORD 2x4 SP No.2 REACTIONS. (size) 2-Mechanical, 3=Mechanical, 4=0-e-0 (min. 0-1-8) Max Ho=4--43(LC 8) Max Uplifl2=50(LC 8), 3=130(LC 1), 4=124(LC 4) Max Grav2=54(LC 1). 3=78(LC 4), 4=223(LC 1) FORCES. (Ib) - Max. Comp./Max. Ten. -All forces 250 Qb) or less except when shown. BRACING - TOP CHORD Structural wood sheathing directly applied or 2-" oc puriins. BOT CHORD Rigid ceiling directly applied or 10.0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCOL=4.2psf; BCDL=S.OpsF, h=1511; Cat II; Exp C; Encl.. GCp1=0.1 B; MWFRS (envelope); cantilever left and right exposed; LumberDOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord rwe load nonconcunentwith any other live loads 3) Refer to girder(s) for buss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 It, uplift at jolm(s) 2 except Gt-lb) 3=130. 4=124. LOAD CASE(S) Standard PE 051 rfi t k.Aj0F i0i(UQ' ORIDP /�,,/S:S pNA i Joe jrUw 1russ we FrIf Plan 1722 IM-A AJack-Open 9 1 Job Reference tlonal apathem TNas. FL Pierce. FL, 30901 Kure.. a. Ll[elo r...[ awn1V1...aft muusnes, me vvea nw ,q,o:.w:,acu,e ID:EaPOUIwCWAO16WSO7vTFdz75cK-Rx40ZQ38LOWYyfzOC wI doXL2 mdh5WPy Dke 1-0-0 4-0-0 LOADING(psf) SPACING- 2-0-0 CSI. DEFL in 00 Udell L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 125 TC 0.09 Vert(LL) -0.00 4-5 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 SC 0.07 Verl(CT) -0.00 4-5 >999 180 BCLL 0.0 Rep Stress Ina YES WB 0.03 Horz(CT) -0.00 3 We Na BCDL 10.0 Code FBC20171TPI2014 Matrix-P Weight: 13@ FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 4-0.0 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No.3 REACTIONS, (arse) 3=Medlanical, 4—Mechanical, 6--0-8-0 (min. 0-1-8) Max Horz5=83(LC 8) Max Uplfi3=59(LC 8), 6=90(1-C 4) Max Grav3=64(LC 1), 4=40(LC 3). 5=220(LC 1) FORCES. (Ib) - Max CompJMax Ten. -All forces 250(Ib) orless exceptwhen shown. NOTES. 1) Wind: ASCE 7-10; Vuft=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf; h=1511; Cat II; Exp C; End., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconmmnt with any other five loads. 3) Refer to girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) 3, 5. LOAD CASE(S) Standard e .Truss rush lype Pia 1722 t7n2-A XA JetlaOpen 1 f Job Reference o tio al m, 1d dRM169arR Pwnw1 S Ulnem l MSc, M Y1e1Ce, rL, :»Wl •••••••••.••"••• ••••-•••-•••••••••• oml• _. ID:EePOUIwCWA01h1v507vTFdYtSdC-v7em14C6JaPa9XDmipkorGn4MFZLURG_HRe2ryDkd 3-o-0 Mo 3—Vjf LOADING(psf) SPACING- 2-0-0 CSI. DEFL in Qoc) Odefl Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.11 Vert(LL) -0.00 3-0 >999 240 MT20 244/190 TCDL 7.0 Lumber DOL 125 I BC 0.08 I Vert(CT) I -0.01 3-4 >999 180 I BCLL 0.0 Rep Stress Ina YES WB 0.00 Horz(CT) -0.01 2 We We BCDL 10.0 Code FBC2017/TPI2014 Matrix-R Weight 10lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No2 TOP CHORD BOT CHORD 2x4 SP No2 WEBS 2x4 SP No.3 BOT CHORD REACTIONS. (size) 4=0-M (min, 0-1-B), 2=Mechanical, 3=Mechanical Max Horz4=57(LC 8) Max Upli84=-21(LC 0). 2--66(LC 8) Max Grav4=103(I.0 1). 2=70(LC 1). 3=53(LC 3) FORCES. Qb) - Max. CompJMax. Ten. - All forces 250 Qb) or less except when shown. Structural wood sheathing directly applied or 3.0-0 oc puffins, except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vuh=160mph (3-sewnd gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opst h=151k Cat II; Exp C; End., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip OOL=1.60 2) This buss has been designed for a 10.0 psf bottom chord live load nonooncorrent with any other live loads. 3) Refer to girders) for truss to buss connections. 4) Provide mechanical connection (by others) of buss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 4, 2. LOAD CASE(S) Standard PE 051 / t b t STA OIL 0 <ORID i,,/SS oNA I I�NG\\\��� I LOADING(psf) SPACING- 2-0-0 CSI. DEFL in 'oc' Udell L/d PLATES . GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.26 Ved(LL) -0.02 4-5>999 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 0.20 Ved(CT) -0.04 45 >999 180 BCLL 0.0 Rep Stress Ina YES WB 0.06 Horz(CT) -0.02 3 n/a n/a BCDL 10.0 Code FBC2017JTP12014 Matra-P Weight 191b FT=20% LUMBER- TOP CHORD W SP Not BRACING - TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid wiling directly applied or 10-M oc bracing. WEBS 2x4 SP No.3 ' REACTIONS. (size) 3--Mechanical, 4--Mechanical, 5=0-8-0 (min. 0-1-8) Max Horz5=124(LC 8) Max Upi8 3i—l04(LC 8), 5=94(LC 4) Max Gmv3=109(LC 1), 4=81(LC 3). 5=283(LC 1) FORCES. (lb) - Max. CompJMax. Ten. -All forces 250 Qb) or less except when shown. NOTES- 1) Wind: ASCE 7-10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf; h=1511; CaL II; Exp C; End., GCpl=0.16; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate gdp DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) Refer to girder(s) for truss to buss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 5 except Qt=1b) 3=104. LOAD CASE(S) Standard a , lass ruse type y Plan 17r2 I; -A .im Jack -Open t 7 Job Reference o Uanal soumem Tnm. FL Pismo. FL, $4951 T.F. Plate Offsets (KY)— 11:0b12 0-1-12) r4.04-0 0.0.4t r4.6-0.0 at-121 LOADING(PS) SPACING- 24)-0 CSI. DEFL. in poc) Wait L/d PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.32 Vert(LL) 0.03 3-4 >999 240 MT20 244/190 TOOL 7.0 ' Lumber DOL 1.25 BC 0.25 Vert(CT) -0.05 3-0 >999 180 SCLL 0.0 Rep Stress Ina YES WB 0.00 Hom(CT) -0.02 2 n/a n/a BCDL 10.0 Code FBC2017rrP12014 Matra-R Weight 16 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD BOT CHORD 2x4 SP No.2 WEBS 2x4 SP No.3 ' BOT CHORD REACTIONS. (sire) 4=04I-0 (min. 0.1.8), 2=Mechanical, 3=Mechanical Max Horz4=-99(LC 8) Max Up11114=43(LC 8), 2=108(LC 8) Max Grav4=177(LC 1). 2=120(LC 1). 3=90(LC 3) FORCES. (Ib) - Max. Comp./Max. Ten. - All forces 250 Qb) or less except when shown. Structural wood sheathing directly applied or 54)-0 cc pudins, except end verticals. Rigid ceiling directly applied or 10-0.0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf, BCDL=5.Opsh h=15ft; Cat 11; Exp C; End., GCpi=0.18; MWFRS (envelope); cantilever left and tight exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord We load noncentxment with any other live loads. 3) Refer to girder(s) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atjoint(s) 4 except at -lb) 2=108. LOAD CASE(S) Standard o • fuss ruse I ype Plan 1722 772-A is Jack Open 23 1 Jab Reference a Oonal Southern Try , FL Pi rc FL, 34951 01 Run: b. TJu 5" 2"" w0e7ZvdFV75ZKMPIIn"7i'PeE G.nRqn_eROtlTWU'A- IN ID:EaPDUIwCVVA01eaAe:u alo Arn n, id-0 8-0-0 1 -0 66.0 M Dead Load Def. - 118 in LOADING(psf) I SPACING- 2-0-0 CSI. DEFL in Owl I/dell Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.26 TC 0.61 Ved(LL) 0.10 4-5 >766 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 I SC 0.47 Vert(CT) -0.18 I 4-5 >444 100 I SCLL 0.0 11 Rep Stress Inv YES B W0.09 Horz(CT) -0.06 3 Na Na BCDL 10.0 Code FBC2017ffP12014 Matrb(-P Weight 26 lb FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 co pudins. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2x4 SP No-3 ' REACTIONS. (size) 3=Mechaniml, 4=1viechanical, 5=041-0 (min. 0-1.8) Max Horz5=165(LC 8) Max Upllft3=147(LC 8), 5=106(1.0 8) Max Gmv3=161(LC 1), 4=120(LC 3), 5=353(LC 1) FORCES. (Ib) - Malt CompJMex. Ten. - All forces 250 (lb) or less except when shown. WEBS 2-5=319/300 NOTES- 1) Wind: ASCE 7.10; Vuit=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.DpsF, h=15$ Cat 11; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plate grip DOL=1.60 2) This truss has been designed for a 10.0 psf bottom chord Me load nonconcunent with any other live loads. 3) Referto girders) for truss to truss connections. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except gt--Ib) 3=147, 5=106. LOAD CASE(S) Standard N_1M_I �\\\� P\\GENS+�`��/i PE L05-1STA / -5O �� ,t.�-1— 1� �P� 71v� Q /F�ORIO�Qi�� ///�SSONAI �ENG\\\��\ spedal f 2x6 II 1z4 11 LOADING(psf) SPACING- 24)-0 CSL DEFL in Qoc) Irdell Ltd PLATES GRIP TOLL 20.0 Plate Grip DOL 1.25 TO 0.20 Veri(LL) 0.02 7-8 >999 240 MT20 2441190 TOOL 7.0 Lumber DOL 1.25 BC 0.21 Veri(CT) .0.02 7-8 >999 180 BCLL 0.0 Rep Stress Ina YES WB 0.07 Harz(CT) -0.05 5 Wa We BCOL 10.0 Code F13C2017[rP12014 Matdx-S Weight 32 lb FT = 20% LUMBER- BRACING - TOP CHORD 2x4 SP No2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 uc puriins. BOT CHORD 2x4 SP No BOT CHORD Rigid caging directly applied or 6-0-0 on bracing. WEBS 2x4 SP No.3 ' REACTIONS. All bearings Mechanical except ()t--length) 8=0-8-0, 7=04l-0. (lb) - Max Horz8=165(LC 8) Max Uplift Ali uplift 100 Ib or less at)oint(s) 5, 8 except 7=-216(LC 8) Max Grav, Ali reactions 250 lb or less at Joint(s) 5, 6 except 8=256(LC 1), 7=359(LC 1) FORCES. (lb) - Max. CompJMax. Ten. -Ail forces 250 (lb) arises except when shown. WEBS 4-7=2511228 NOTES- 1) Unbalanced roof live loads have been considered for this design. - 2) Wind: ASCE 7-10; Volt=160mph (3-second gust) Vasd=124mph; TCDL=4.2psF, BCDL=S.Opsf, h=15ft; Cat. II; Exp C; Encl., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed; Lumber DOL=1.60 plat: grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at)oinl(s) 5, 8 except at --lb) 7.216. LOAD CASE(S) Standard PE / I b 1 -TA OF p`�(�-1-1� 1i/'�F�.<ORIOP SONA��ENG10 \\\��\ d` f 2x6 II 1x4 II LOADING(psf) SPACING- 2-0-0 CS[. DEFL. in Coo) Well Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.19 Vert(LL) 0.03 9 >999 240 MT20 244/190 TCDL 7.0 "Lumber DOL 1.25 BC 0.15 Vart(CT) 0.03 9 >999 180 BCLL 0.0 Rep Stress [nor YES WB 0.06 Horz(CT) -0.02 6 We n/a BCDL 10.0 Code FBC2017/TP]2014 Matra-S Weight 34 lb FT= 20% LUMBER- BRACING - TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins. BOT CHORD 2x4 SP No2 BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing. WEBS 2x4 SP No.3 ' REACTIONS. All bearings Mechanical except at=length)10=0-8-0, 8=0A-0. Cb) - Max Hmz1(M65(LC 8) Max Uplift A0 uplift 1001b or less etjoint(s) 6,10 except 8=202(.0 8) Max Grav Ali reactions 250 lb or less atJoint(s) 6,7 except 10=254(.0 1), 8=356(LC 1) FORCES. Cb)- Max. CompJMax. Ten. -All forces 250 Cb) or less exceptwhen shown. NOTES- 1) Unbalanced mof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=S.Opsf, h=15ft; Cat. II; Exp C; Encl.. GCpl=0.18; MWFRS (envelope); cantilever left and right exposed: Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load noncencurrent with any other live loads. 5) Referto girder(s) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1001h uplift at Joint(s) 6,10 except Ct=1b) 8=202. LOAD CASE(S) Standard \�CENS�.\�.i PE 051 1 r I STA OF ORID s ON I l IS O NSS NsS lype Plan 1722 anaa J9G JVIY Roof Special G✓der t t Job Reference o 'an Southem7rum, FL Pierce, FL., 34951 con:a.wes amneu�ornrrn o.ews..r.c''T6LxsGhhwOAZFOWuzYCNse0ke78Z8Pk3.P� ID:EaPOUIwCWA016WS07vTFdz75c4G5 Y DkY 6108 3M II tx4 II 3x4 = LOADING(psf) SPACING- 2-0-0 CSI. DEFL in (loc) 11de6 L/d PLATES GRIP MILL 20.0 Plate Grip DOL 1.25 TC 0.47 Vert(LL) -0.03 7-8 >999 240 MT20 2441190 TCDL 7.0 LumberDOL 1.25 BC OA7 Vert(CT) -0.05 7.8 >702 180 BCLL 0.0 Rep Stress Ina NO WB 0.07 Horz(CT) -0.00 5 n/a Na BCDL 10.0 Code FBC2017/TPI2014 MabaS Weight 401b FT=20% LUMBER- BRACING. TOP CHORD 2x4 SP No.2 TOP CHORD Structural wood sheathing directly app8ed or 6-0-0 no pudins, except SOT CHORD 2x4 SP M 31 end verticals. WEBS 2x4 SP No.3 `ExceW BOT CHORD Rigid ceiling directly applied or 10.0.0 oc bracing. W 1: 24 SP No.2 REACTIONS. All bearings 04i-0 except (jt--length) S=Mechanical, 7=Mechanipl. (Ib)- Max Horz9=134(LC8) Max Uplift All uplift 100 lb or less atjoint(s) 5,9 except 7=-241(LC 8), 8=160(LC 8) Matt Grav All reactions 250lb or less at jeint(s) 5,9 except 7=491(LC 1), 6=688(LC 1) - FORCES. (lb) - Max Comp./Max. Ten. - All forces 250 (Ib) or less except when shown NOTES- 1) Wind: ASCE 7.10; Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.Opsf, h=15ft; Cat 11; Exp C. Encl., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Provide adequate drainage to prevent water ponding. 3) This truss has been designed for a 10.0 pat bottom chord live load nonconcurrent with any other live loads. 4)Refer to girders) for buss to truss connections. 5) Refer to girders) for truss to truss connections. 6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1100 lb uplift at joint(s) 5, 9 except at --lb) 7=241, 8=160. 7) Gap between Inside of top chord bearing and first diagonal or vertical web shall not exceed 0.5001in. 8) Hanger(s) or other connection devices) shall be provided sufficient to support concentrated load(s) 64 lb down and 21 lb up at 0-9-13 on top chord, and 794 lb down and 284 lb up at 6-8-12 on bottom chord. The design/selecdon of such connection device(s) is the responsibility of others. 9) in the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase--1.25, Plate Increase=1.25 Uniform Loads (pit) Vert 3-4=54, 45=-54, 6-9=20 Concentrated Loads Qb) Vert: 10=-6011=794(B) PE 051 f I _ STA OF OR I O SS 4,4 = 4x4 = Dead Load Deft. - 61161n Id LOADING(psf) SPACING- 2-M CSI. DEFL. in (Ioc) I/deff Ud PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.86 Vert(LL) -0.30 1-9 >868 240 MT20 2441190 TCDL 7.0 Lumber DOL 1.25 BC 1.00 Vert(CT) -0.63 1-9 >416 180 SCLL 0.0 Rep Stress Ina YES WB 0.20 Hom(CT) 0.05 7 No n/a Weight 102 lb FT = 20% BCDL 10.0 Code FBC2017/TPI2014 Mab xS LUMBER- TOP CHORD 2x4 SP No.2 BRACING - TOP CHORD Structural mod sheathing directly applied or 4-2-7 oc pudlns. BOT CHORD 2x4 SP No.2 BOT CHORD Rigid telling directly applied or 2-2-0 oc bracing. WEBS 2x4 SP No.3 ' WEDGE Let, 2x6 SP No.2 SLIDER Right 2x4 SP No.3 25-11 REACTIONS. (size) 7=11,11echanical, 1=0-8-0 (min. 0-1-0) Max Horz 1=76(LC 8) Max Uplift7=264(LC 9), 1=271(LC 8) Max Grav7=814(LC 1).1=814(LC 1) FORCES. (lb) - Max CompJMax Ten. - All forces 250 (Ib) or less except when shown. TOP CHORD 1-2=1546/547, 2-3=12201372, 3-4=10811368, 45=1196/369, 5-6=-1358/492, 6-7--1418/482 BOTCHORD 1-9=516N381,8-9=221N081,7-8=a69/1216 WEBS 2-9=-380/331, 3-9-44/325, 45=221251, 5-8=-2191260 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10; Vuit=160mph (3second gust) Vasd=124mph; TCDL=4.2psf; BCDL=5.OpsF h=1510 Cat 11; Exp C; End, GCPI--0.18: MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) Refer to girder(s) for truss to truss connections. 6) Provide mechanics] connection (by others) of truss to bearing plate capable of withstanding 100lb uplift atjoint(s) except Crib) 7-264, 1=271. LOAD CASE(S) Standard M. PE X6051 \ i 1 O STA OF 10�� c�-1-lS itvQ l�. %,FS��ORIDP�\a�\�\ 2 ,. W72-A Oder 4x7 = 14 tx4 II 15 4x7 = Dead Load Dell. =1/a in I I U7 = 314 = 4x4 = 3xe = 3x4 = —1 LOADING(psf) SPACING- 2-0-0 CSI. TC OAS DEFL. in (hoc) Udefl Ud Vert(LL) 0.18 11-13 1999 240 PLATES GRIP MT20 244/190 TCLL 20.0 TCDL 7.0 Plate Grip DOL 1.25 Lumber DOL 1.25 BC 0.93 Vert(CT) .0.28 1-13 >959 180 BCLL 0.0 Rep Stress [nor NO WB 0.22 Horz(CT) 0.10 9 We n/a Weight 1171b FT = 20°% BCDL 10.0 Code FBC2017iTP12014 MatrixS LUMBER- TOP CHORD 2x4 SP No.2 `Except* BRACING - TOP CHORD Structural wood sheathing directly applied or 3.0-11 oc pudins. T3: 2x4 SP M 31 BOT CHORD Rigid ceiling directly applied or 4-11-1 oc bracing. BOT CHORD 2x4 SP No.2 ' WEBS 20 SP No.3 SLIDER Left 2x6 SP No.2 2.0.14, Right 2x6 SP No.2 1-113 REACTIONS. (size) 1=0-8-0 (m1n.0-1-12), 9=0-" (min. 0.1-13) Max Horzl= 61(LC 28) Max UpI1lU=704(LC 8), 9=724(LC 9) Max Grav1=1496(1_0 1), 9=1538(LC 1) FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (lb) or less except when shown. TOP CHORD 1-2=-319711561. 2.3=314511568. 3-4=304211486, 4-14=307911564, 5-14=307911564, 5-15=307911564, 6-15=-3079/1564, 6-7=292611432, 7-8=28D4I1401, 8-9-2862/1398 BOT CHORD 1-13=1429/2864,12-13=13042809, 11-12=1304/2809,11-16=-123112708, 10-16=123112708, 9-10=-1169/2465 WEBS 3.13=-200f299,4.13=91/568,4-11=237/427,5-11=-447/405,6.11=-2921554, 6.10=15/435, 7-10=-2101402 NOTES- 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-10: Vult=160mph (3-second gust) Vasd=124mph; TCDL=4.2psh, BCDL=5.OpsF h=15% CaL II; Exp C; End., GCpi=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 3) Provide adequate drainage to prevent water ponding. 4) This truss has been designed for a 10.0 psi bottom chord live load nonconcuvent with any other five loads. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100111 uplift atjoint(s) except (It-ib)1=704, 9=724. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 225 lb down and 280 Ib up at B-0.0, 107 lb down and 150 lb up at 10-0-12. 107111 down and 150 lb up at 11-8-0. and 107 lb down and 150 It, up at 13-3-0, and 225 lb down and 280111 up at 15-4-0 on top chord, and 2B5 lb down and 134 lb up at 841-0, 80 lb down at 10-0-12. 80 lb down at 11-8.0, and 80 lb down at 133-4, and 285 Ib down and 134 lb up at 153�4 on bottom chord. The design/selection of such connection device(s) Is the responsibility of others. 7) In ftie LOAD CASES) section, loads tied to the face of the truss are noted as front (F) or back (B). �t it I III GEN PE 7 051�o LOAD CASE(S) Standard 1) Dead + Roof Live (balanced): Lumber Increase=1.25, Plate Increase=1.25 Uniform Loads (pif) Vert 14=54, 4-6=54, 6-9=-54,1-9=20 Concentrated Loads (Ib) Vert: 4=178(F) 6=178(F)12-54(F) 13=285(F) 5=-107(F)11=64(F)10=285(F)14-707(F)15=107(F)16=54(F) 1 STATEBF _ s ONA �iE�G\\\�N� 20 9 LOADING(psf) SPACING- 2-0-0 CSI. DEFL In (loc) Wait Lid PLATES GRIP TCLL 20.0 Plate Grip DOL 1.25 TC 0.06 Ved(LL) n/a - We 999 MT20 244/190 TCDL 7.0 Lumber DOL 1.25 BC 0.04 Vert(CT) Na - n/a 999 BCLL 0.0 Rep Stress Ina YES WB 0.00 Hoa(CT) -0.00 2 n1a n/a BCDL 10.0 Code FBC2017fTP12014 Matrix-P Weight 6to FT=20% LUMBER- BRACING - TOP CHORD 2x4 SP N0 3 TOP CHORD structural wood sheathing directly applied or 24-0 oc puriins. BOT CHORD 2x4 SP No.3 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc braclng. REACTIONS. (size) 1=2b0 (min. 0-1-8), 2=24-0 (min. 0-"), 3-2.4-0 (min. 0-1-8) Max Horz1=33(LC 8) Max Up8IH=18(LC 8), 2=-10(LC 8) Max Gmvi=59(LC 1), 2=43(LC 1), 3=32(LC 3) FORCES. (Ib) - Max. CompJMax. Ten. -All forces 250 (Ib) or less except when shown. NOTES- 1)Wind: ASCE 7-10; Vult=160mph (3-sewnd gust) Vasd=124mph; TCDL=4.2psf; BCOL=5.0psi; h=15ft; CaL 11; Exp C; End., GCpl=0.18; MWFRS (envelope); cantilever left and right exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. - 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrenl with any other live loads. 4) Bearing atjoird(s) 2 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift atJoint(s)1, 2. LOAD CASE(S) Standard 2 3 2x4 � 2x4 It. LOADING(psf) SPACING- 2-0-0 CSI. DEFL. In (toc) ItdeB Ltd 999 PLATES GRIP MT20 244t190 TCU 20.0 Plate Grip DOL 1.25 TC 0.31 Vert(LL) We - n1a TCDL 7.0 Lumber DOL 1.25 SC 0.24 Ved(CT) We - nla 999 BCU 0.0 Rep Stress lncr YES WB 0.00 Horz(CT) 0.00 rda Na Weight: 14 lb FT=20% BCD L 10.0 Code FBC20177rP12014 MatrixP LUMBER - TOP CHORD 2x4 SP No.3 BOT CHORD 2x4 SP No.3 WEBS 2x4 SP No.3 REACTIONS. (size) 1=4-4-0 (min. 0-1-8), 3--4-0-0 (min. 0-1-8) Max Horz1=71(LC 8) Max Uplifts=39(LC 8), 3=-88(LC 8) Max Grev1=128(LC 1), 3=128(LC 1) FORCES. (Ib) - Max. CompJMax. Ten. - All forces 250 (Ib) or less except when shown BRACING - TOP CHORD Structural wood sheathing directly applied or4-4-0 oc puffins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. NOTES- 1) Wind: ASCE 7-10; Vult=160mph (3-second gust) Vasd--124mph; TCDL=42psf; BCDL=5.0psf; h=15tk Cat II; Exp C; Encl., GCpi=0.18; MWFRS (envelope); cantilever left and dght exposed ; Lumber DOL=1.60 plate grip DOL=1.60 2) Gable requires continuous bottom chord bearing. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcunent with any other live loads. 4) Provide mechanics] connection (by others) of truss to bearing plate capable of withstanding 100 lb uprr t at)oint(s)1, 3. LOAD CASE(S) Standard " V i -\.XCENS+�` PE 051n I --lot STApF 0;C jc' n f -1 S itv�ej ////ss o�l