RESIDENTIAL ENERGY CONSERVATION CODE DOCUMENTATION CHECKLIST
4 1q o 4-oZ'o,"o,
Florida Department of Business and Professional Regulation
Simulated Performance Alternative (Performance) lfietho APR 16 Z019
ST. Lucie County, r•=^••^��
Applications for compliance with the 2017 Florida Building Code, Energy Conservation via fhe
residential Simulated Performance Method shall include: SCANNED _
� BY
(� This checklist St. Lucie County
�Y/A Form R405 report that documents that the Proposed Design complies with Section
R405.3 of the Florida Energy Code. This form shall include a summary page
indicating home address, a -ratio and the pass or fail status along with summary
areas and types of components, whether the home was simulated as a worst -case
orientation, name and version of the compliance software tool, name of individual
completing the compliance report (one page) and an input summary checklist that can
b eysed for field verification (usually four pages/may be greater).
Energy Performance Level (EPL) Display Card (one page)
f�H AC system sizing and selection based on ACCA Manual S orper exceptions provided in Section R403.7
Mandatory Requirements (five pages)
Required prior to CO for the Performance Method:
❑ Air Barrier and Insulation Inspection Component Criteria checMist (Table R402.4.1.1 -
one page)
❑ A completed Envelope Leakage Test Report (usually one page)
❑ If Form R405 duct leakage type indicates anything other than "default leakage" then a completed
Form R405 Duct Leakage Test Report (usually one page)
REVIEWED FOR
CODE COMPLIANCE
ST• LU SOCC LINTY
4/5/2019 9:01:26 AM EnergyGauge® USA 6.0.02 - RaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
FORM R405-2017
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: EDGAR RODRIGUEZ
Builder Name:
.
Street: 1910 GEORGIA AVE
Permit Office: FT. PIERCE
City, State, Zip: FT PIERCE, FL,
Permit Number:
Owner: EDGAR RODRIGUEZ
Jurisdiction:
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate
Zone 2 )
1. New construction or existing New (From Plans)
9. Wall Types (960.0 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 960.00 ft2
b. N/A
R= ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (1108.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=30.0 1108.00 ft2
6. Conditioned floor area above grade (ft2) 1108
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(142.0 sqft.) Description Area
a. Sup: Attic, Rat: Attic, AH: Attic
6 148.8
a. U-Factor: Sgl, U=0.96 142.00 ft2
SHGC: SHGC=0.42
b. U-Factor: N/A ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC:
a. Central Unit
29.4 SEER:16.00
c. U-Factor: N/A ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: N/A ft2
a. Electric Strip Heat
15.5 COP:1.00
SHGC:
Area Weighted Average Overhang Depth: 2.000 ft.
Area Weighted Average SHGC: 0.420
14. Hot water systems
a. Electric
Cap: 40 gallons
8. Floor Types (1108.0 sqft.) Insulation Area
EF: 0.920
a. Slab -On -Grade Edge Insulation R=0.0 1108.00 ft2
b. Conservation features
b. N/A R= ft2
None
c. N/A R= ft2
15. Credits
Pstat.
Total Proposed Modified Loads: 44.22
Glass/Floor Area: 0.128
PASS
Total Baseline Loads: 45.55
I hereby certify that the plans and specifications covered by
Review of the plans and
OFVE STq
this calculation are in compliance with the Florida Energy
specifications covered by this
y , _ l�0
Code.
calculation indicates compliance
with the Florida Energy Code.
F. rrnr r „y t0
PREPARED BY:
Before construction is completed
Fs
DATE: - -
this building will be inspected for
compliance with Section 553.908
y
I hereby certify that this building, as designed, is in compliance
Florida Statutes.
with the Florida Energy Code.
C0 WF S4�
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
envelope leakage test report with envelope leakage no greater than 4.00 ACH50 (R402.4.1.2).
4/5/2019 9:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 4
FORM R4nF_7n17 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title:
Building Type:
Owner Name:
# of Units:
Builder Name:
Permit Office:
Jurisdiction:
Family Type:
New/Existing:
Comment:
EDGAR RODRIGUEZ
User
EDGAR RODRIGUEZ
1
FT. PIERCE
Single-family
New (From Plans)
Bedrooms: 4
Conditioned Area: 1108
Total Stories: 1
Worst Case: No
Rotate Angle: 0
Cross Ventilation:
Whole House Fan:
Address Type: Street Address
Lot #
Block/Subdivision:
PlatBook:
Street: 1910 GEORGIA AVE
County: St. Lucie
City, State, Zip: FT PIERCE,
FL,
CLIMATE
Design Location
Design Temp
TMY Site 97.5 % 2.5 %
Int Design Temp Heating Design Daily Temp
Winter Summer Degree Days Moisture Range
FL,
Fort Pierce FL_VERO_BEACH_MUNI 39 90
70 75 J 299 62 Low
BLOCKS
Number
Name
Area Volume
1
Blockl
1108 8864
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms Infil ID Finished Cooled Heated
1
Main
1108 8864 Yes 3
4 1 Yes Yes Yes
FLOORS
#
Floor Type
Space Perimeter R-Value
Area Tile Wood Carpet
1 Slab -On -Grade Edge Insulatio Main 121 ft 0
1108 ft' - 0 0 1
ROOF
#
Type
Roof Gable Roof
Materials Area Area Color
Solar SA Emitt Emitt Deck" Pitch
Absor. Tested Tested Insul. (deg)
1
Hip Composition shingles 1200 ft' 0 ft' Light
0.96 No 0.9 No 0 22.6
ATTIC
#
Type
Ventilation Vent Ratio (1 in)
Area RBS IRCC
1
Full attic
Vented 150 1108 ft' N N
CEILING
#
Ceiling Type
Space R-Value Ins Type Area Framing Free Truss Type
1
Under Attic (Vented)
Main 30 Blown
1108 ft2 0.11 Wood
4/5/2019 9:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 2 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
WALLS
Adjacent
Cavity Width Height
Sheathing Framing Solar
Be!"
it
nrnt
Tn Wall Typeow
Space
_ 1
N
Exterior Concrete Block- Int Insul Main
4.0999 32 8
256.0 ft'
0 0.15
0
_ 2
E
Exterior Concrete Block - Int Insul Main
4.0999 28 8
224.0 ft'
0 0.15
0
_ 3
S
Exterior Concrete Block - Int Insul Main
4.0999 32 8
256.0 ft'
0 0.15
0
4
W
Exterior Concrete Block - Int Insul Main
4.0999 28 8
224.0 ft'
0 0.15
0
DOORS
#
Ornt Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
W Insulated Main
None
.46 3
6 8
20 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Ornt ID Frame Panes NFRC
U-Factor SHGC Imp
Area Depth
Separation
Int Shade
Screening
1
N 1 Metal Single (Tinted) Yes
0.96 0.42 N
12.0 ft' 2 ft 0 in
1 ft 0 in
None
None
2
N 1 Metal Single (Tinted) Yes
0.96 0.42 N
6.0 ft' 2 ft 0 in
1 ft 0 in
None
None
3
N 1 Metal Single (Tinted) Yes
0.96 0.42 N
12.0 ft' 2 ft 0 in
1 ft 0 in
None
None
4
E 2 Metal Single (Tinted) Yes
0.96 0.42 N
12.0 ft' 2 ft 0 in
1 ft 0 in
None
None
5
E 2 Metal Single (Tinted) Yes
0.96 0.42 N
12.0 ft' 2 ft 0 in
1 It 0 in
None
None
6
E. 2 Metal Single (Tinted) Yes,
0.96 0.42 N
24.0 ft' 2 It 0 in
1 It 0 in
None
None
7
S 3 Metal Single (Tinted) Yes
0.96 0.42 N
28.0 ft' 2 ft 0 in
1 ft 0 in
None
None
8
W 4 Metal Single (Tinted) Yes
0.96 0.42 N
24.0 ft' 2 ft 0 in
1 ft 0 in
None _
None
9
W 4 Metal Single (Tinted) Yes
0.96 0.42 N
12.0 ft' 2 ft 0 in
1 ft 0 in
None
None
INFILTRATION
#
Scope
Method SLA
CFM 50 ELA EgLA iACH
ACH 50
1 Wholehouse Proposed ACH(50) .000203
590.9 32.44 61.01 .1473
4
HEATING SYSTEM
#
System Type Subtype
Efficiency
Capacity
Block
Ducts
1
Electric Strip Heat/ None
COPA
15.5 kStu/hr
1
sys#1
COOLING SYSTEM
#
System. Type Subtype
Efficiency
Capacity Air Flow
SHR Block
Ducts
1
Central Unit/ None
SEER: 16 29.4 kBtu/hr 882 cfm
0.75 1
sys#1
4/5/2019 9:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 4
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HOT WATER SYSTEM
# System Type SubType
Location EF Cap Use
SetPnt
Conservation
1 Electric None
Main 0.92 40 gal 70 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart # Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft'
DUCTS
/ --- Supply ---
--- Return --- Air
CFM 25
CFM25
HVAC #
V # Location R-Value Area
Location Area Leakage Type Handler
TOT
OUT
ON RLF
Heat Cool
1 Attic 6 148.8 ft
Attic 47.2 ft' Default Leakage Attic
(Default)
(Default)
1 1
TEMPERATURES
Programablre'Thermostat:
Ceiling Fans:
,]Y fx�]]
Heating Jan Feb Mar
] M:y[[` ]]] r[[ ]] f[[ ]]
] AApr [ ] Maec
Jun rl Jul ri Aug
[X]
[ ] S p
[ j
L.l
No
rIX
Oct Nov
[r)C')
Dec
Venting [ ]Jan [ ]Feb X Mar
t J l J l J
] [ ] [ ]Jun [ Jul [ Aug
y lXJ
[ ]Sep
lxl
[X�
[ ]
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type 1
2
3 4 5 6 7
8
9
10 11
12
Cooling (WD) AM 78
78
78 78 78 78 78
78
80
80 80
80
PM 80
80
78 78 78 78 78
78
78
78 78
78
Cooling (WEH) AM 78
78
78 78 78 78 78
78
78
78 78
78
PM 78
78
78 78 78 78 78
78
78
78 78
78
Heating (WD) AM 66
66
66 66 66 68 68
68
68
68 68
68
PM 68
68:.
68 68 68 68 68
68
68
68 66
66
Heating (WEH) AM 66
66
66 66 66 68 68
68
68
68 68
68
PM 68
68
68 68 68 68 68
68
68
68 66
66 '.
MECHANICAL VENTILATION
Type Supply CFM
Exhaust CFM Fan Watts HRV Heating System
Run Time Cooling System
None 0
0 0 1 - Electric Strip Heat
0%
1 - Central Unit
MASS
Mass Type
Area Thickness Furniture Fraction
Space
Default 8 Ibs/s .ft.
0 ft' 0 ft 0.3
Main
Name:
Rating Compant:
Signature:
Date:
4/5/2019 9:01 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 4
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 97
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply ducts R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Attic
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
4
13. Cooling system: Capacity
29.4
a) Split system SEER
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1108
d) Room uni1/PTAC EER
e) Other
16.0
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.960
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.420
14. Heating system: Capacity
15.5
c) Area
7c.
142.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
B. Skylights
c) Electric resistance COP
1.0
a) U-factor:(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
0 Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.92
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior:
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
10B1.
2. Masonry (Insulation R-value)
10B2.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
a) Under attic
11a.
30.0
b) Cross ventilation
No
b) Single assembly
11b.
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
f) Programmable thermostat
Yes
'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy
saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL
display card will be completed based on installed code compliant features.
Builder Signature:
Address of New Home: 1910 GEORGIA AVE City/FL Zip: FT PIERCE. FL
4/5/2019 9:01:31 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
Florida Building Code, Energy Conservation, 6th Edition (2017)
3tory Requirements for Residential Performance, Prescriptive and ERI Methods
ADDRESS: 1910 GEORGIA AVE Permit Number:
FT PIERCE, FL
MANDATORY REQUIREMENTS See individual code sections for full details.
SECTION R401 GENERAL
R401.3 Energy Performance Level (EPL) display card (Mandatory). The building official shall require that an energy performance level (EPL)
display card be completed and certified by the builder to be accurate and correct before final approval of the building for occupancy. Florida law
(Section 553.9085, Florida Statutes) requires the EPL display card to be included as an addendum to each sales contract for both presold and
nonpresold residential buildings. The EPL display card contains information indicating the energy performance level and efficiencies of components
installed in a dwelling unit. The building official shall verify that the EPL display card completed and signed by the builder accurately reflects the plans
and specifications submitted to demonstrate code compliance for the building. A copy of the EPL display card can be found in Appendix RD.
R402.4 Air leakage (Mandatory). The building thermal envelope shall be constructed to limit air leakage in accordance with the requirements of
Sections R402.4.1 through R402.4.5.
Exception: Dwelling units of R-2 Occupancies and multiple attached single family dwellings shall be permitted to
comply with Section C402.5.
❑ R402.4.1 Building thermal envelo'jree building thermal envelope shall comply with Sections R402.4.1.1 and R402.4.1.2.
The sealing methods between dissimilar materials shall allow for differential expansion and contraction.
R402.4.1.1 Installation.The components of the building thermal envelope as listed in Table R402.4.1.1 shall be installed in accordance
with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as applicable to the method of construction. Where required
by the code official, an approved third party shall inspect all components and verify compliance.
R402.4.1.2 Testing. The building or dwelling unit shall be tested and verified as having an air leakage rate not exceeding seven air
changes per hour in Climate Zones 1 and 2, and three air changes per hour in Climate Zones 3 through 8. Testing shall be conducted in
accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 pascals). Testing shall be conducted by either .r
individuals as defined in Section 553.993(5) or (7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i) or
an approved third party. A written report of the results of the test shall be signed by the party conducting the test and provided to the code -
official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
Exception: Testing is not required for additions, alterations, renovations, or repairs, of the building thermal envelope of existing
buildings in which the new construction is less than 85 percent of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or
other infiltration control measures.
2. Dampers including exhaust, intake, makeup air, backdraft and flue dampers shall be closed, but not sealed beyond intended
infiltration control measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the lest, shall be turned off.
6. Supply and return registers, if installed at the time of the test, shall be fully open.
R402.4.2 Fireplaces. New wood -burning fireplaces shall have tight -fitting flue dampers or doors, and outdoor combustion air. Where
using tight -fitting doors on factory -built fireplaces listed and labeled in accordance with UL 127, the doors shall be tested and listed for the
fireplace. Where using tight -fitting doors on masonry fireplaces, the doors shall be listed and labeled in accordance with UL 907.
❑ R402.4.3 Fenestration air Ieakage.Windows, skylights and sliding glass doors shall have an air infiltration rate of no more than 0.3 cfm per
square foot (1.5 Us/m2), and swinging doors no more than 0.5 cfm per square foot (2.6 Us/m2), when tested according to NFRC 400 or
AAMA/ WDMA/CSA 101/I.S.2/A440 by an accredited, independent laboratory and listed and labeled by the manufacturer.
Exception: Site -built windows, skylights and doors.
4/5/2019 9:01 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 'I of 5
MANDATORY REQUIREMENTS - (Continued)
❑ R402.4.4 Rooms containing fuel -burning appliances. In Climate Zones 3 through 8, where open combustion air ducts provide combustion air to
open combustion fuel burning appliances, the appliances and combustion air opening shall be located outside the building thermal envelope or
enclosed in a room, isolated from inside the thermal envelope. Such rooms shall be sealed and insulated in accordance with the envelope requirements
of Table R402.1.2, where the walls, floors and ceilings shall meet not less than the basement wall R-value requirement. The door into the room shall be
fully gasketed and any water lines and ducts in the room insulated in accordance with Section R403. The combustion air duct shall be insulated where it
passes through conditioned space to a minimum of R-8.
Exceptions:
1. Direct vent appliances with both intake and exhaust pipes installed continuous to the outside.
2. Fireplaces and stoves complying with Section R402.4.2 and Section R1006 of the Florida Building Code, Residential.
❑ R402.4.5 Recessed lighting. Recessed luminaires installed in the building thermal envelope shall be sealed to limit air leakage
between conditioned and unconditioned spaces. All recessed luminaires shall be IC -rated and labeled as having an air leakage rate not
more than 2.0 cfm (0.944 L/s) when tested in accordance with ASTM E283 at a 1.57 psf (75 Pa) pressure differential. All recessed
luminaires shall be sealed with a gasket or caulk between the housing and the interior wall or ceiling covering.
R403.1 controls. SECTION R403 SYSTEMS
❑ R403.1.1 Thermostat provision (Mandatory).. At least one thermostat shall be provided for each separate heating and cooling system.
❑ R403.1.3 Heat pump supplementary heat (Mandatory). Heat pumps having supplementary electric -resistance heat shall have controls
that, except during defrost, prevent supplemental heat operation when the heat pump compressor can meet the heating load.
❑ R403.3.2 Sealing (Mandatory) All ducts, air handlers, filter boxes and building cavities that form the primary air containment passageways
for air distribution systems shall be considered ducts or plenum chambers, shall be constructed and sealed in accordance with Section
C403.2.9.2 of the Commercial Provisions of this code and shall be shown to meet duct tightness criteria below.
Duct tightness.shall be verified by testing in accordance with ANSI/RESNET/ICC 380 by either individuals as defined in Section 553.993(5) or
(7), Florida Statutes, or individuals licensed as set forth in Section 489.105(3)(f), (g) or (i), Florida Statutes, to be "substantially leak free" in
accordance with Section R403.3.3.
❑ R403.3.2.1 Sealed air handler. Air handlers shall have a manufacturer's designation for an air leakage of no more than 2 percent
of the design airflow rate when tested in accordance with ASHRAE 193.
❑ R403.3.3 Duct testing (Mandatory). Ducts shall be pressure tested to determine air leakage by one'of the following methods:
1, Rough -in test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the system, including the.,. .
manufacturers air handler enclosure if installed at the time of the test. All registers shall be taped or otherwise sealed during th'e,test=-
2. Postconstruction test: Total leakage shall be measured with a pressure differential of 0.1 inch w.g. (25 Pa) across the
entire system, including the manufacturer's air handler enclosure. Registers shall be taped or otherwise sealed during the
test.
Exceptions:
1. A duct air leakage test shall not be required where the ducts and air handlers are located entirely within the building
thermal envelope.
2. Duct testing is not mandatory for buildings complying by Section 405 of this code. -
A written report of the results of the test shall be signed by the party conducting the test and provided to the code official.
❑ R403.3.5 Building cavities (Mandatory). Building framing cavities shall not be used as ducts or plenums.
❑ R403.4 Mechanical system piping insulation (Mandatory). Mechanical system piping capable of carrying fluids above 1057 (41'C)
or below 55°F (13°C) shall be insulated to a minimum of R-3.
❑ R403.4.1 Protection of piping insulation. Piping insulation exposed to weather shall be protected from damage, including that
caused by sunlight, moisture, equipment maintenance and wind, and shall provide shielding from solar radiation that can cause
degradation of the material. Adhesive tape shall not be permitted.
El accordance
Heated water circulation and temperature maintenance systems (Mandatory). Heated water circulation systems shall be in
accordance with Section R403.5.1.1. Heat trace temperature maintenance systems shall be in accordance with Section R403.5.1.2.
Automatic controls, temperature sensors and pumps shall be accessible. Manual controls shall be readily accessible.
R403.5.1.1 Circulation systems. Heated water circulation systems shall be provided with a circulation pump. The system return
❑ pipe shall be a dedicated return pipe or a cold water supply pipe. Gravity and thermosiphon circulation systems shall be prohibited.
Controls for circulating hot water system pumps shall start the pump based on the identification of a demand for hot water within the
occupancy. The controls shall automatically turn off the pump when the water in the circulation loop is at the desired temperature and
when there is no demand for hot water.
❑ R403.5.1.2 Heat trace systems. Electric heat trace systems shall comply with IEEE 515.1 or UL 515. Controls for such systems
shall automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping in accordance
with the times when heated water is used in the occupancy.
4/5/2019 9:01 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 2 of 5
MANDATORY REQUIREMENTS - (Continued)
4403.5.6 Heat traps (Mandatory). Storage water heaters not equipped with integral heat traps and having vertical pipe risers shall have
heat traps installed on both the inlets and outlets. External heat traps shall consist of either a commercially available heat trap or a
downward and upward bend of at least 3 % inches (89 mm) in the hot water distribution line and cold water line located as close as possible
to the storage tank.
R403.5.6 Water heater efficiencies (Mandatory).
❑ R403.5.6.1.1 Automatic controls. Service water -heating systems shall be equipped with automatic temperature controls capable
of adjustment from the lowest to the highest acceptable temperature settings for the intended use. The minimum temperature
setting range shall be from 100°F to 140°F (38°C to 60°C).
El
R403.5.6.1.2 Shut down. A separate switch or a clearly marked circuit breaker shall be provided to permit the power supplied to
electric service systems to be turned off. A separate valve shall be provided to permit the energy supplied to the main burner(s) of
combustion types of service water -heating systems to be turned off.
R403.5.6.2 Water -heating equipment. Water -heating equipment installed in residential units shall meet the minimum efficiencies of
Table C404.2 in Chapter 4 of the Florida Building Code, Energy Conservation, Commercial Provisions, for the type of equipment installed.
Equipment used to provide heating functions as part of a combination system shall satisfy all stated requirements for the appropriate
water -heating category. Solar water heaters shall meet the criteria of Section R403.5.6.2.1.
❑ R403.5.6.2.1 Solar water -heating systems. Solar systems for domestic hot water production are rated by the annual solar energy
factor of the system. The solar energy factor of a system shall be determined from the Florida Solar Energy Center Directory of
Certified Solar Systems. Solar collectors shall be tested in accordance with ISO Standard 9806, Test Methods for Solar Collectors,
and SRCC Standard TM-1, Solar Domestic Hot Water System and Component Test Protocol. Collectors in installed solar
water -heating systems should meet the following criteria:
1. Be installed with a tilt angle between 10 degrees and 40 degrees of the horizontal; and
2. Be installed at an orientation within 45 degrees of true south.
R403.6 Mechanical ventilation (Mandatory). The building shall be provided with ventilation that meets the requirements of the
Florida Building Code, Residential, or Florida Building Code, Mechanical, as applicable, or with other approved means of ventilation
including: Natural, Infiltration or Mechanical means. Outdoor air intakes and exhausts shall have automatic or gravity dampers that
close when the ventilation system is not operating.
R403.6.1 Whole -house mechanical ventilation system fan efficacy. When installed to function as a whole -house mechanical
EJ ventilation system, fans shall meet the efficacy requirements of Table R403.6.1.
Exception: Where whole -house mechanical ventilation fans are integral to tested and listed HVAC equipment, they shall be
powered by an electronically commutated motor.
R403.6.2 Ventilation air. Residential buildings designed to be operated at a positive indoor pressure or for mechanical ventilation
El shall meet the fallowing criteria:
1. The design air change per hour minimums for residential buildings in ASHRAE 62.2, Ventilation for Acceptable
Indoor Air Quality, shall be the maximum rates allowed for residential applications.
2. No ventilation or air-conditioning system make-up air shall be provided to conditioned space from attics,
crawlspaces, attached enclosed garages or outdoor spaces adjacent to swimming pools or spas.
3. If ventilation air is drawn from enclosed space(s), then the walls of the spaces) from which air is drawn shall be
insulated to a minimum of R-11 and the ceiling shall be insulated to a minimum of R-19, space permitting, or R-10
otherwise.
R403.7 Heating and cooling equipment (Mandatory).
R403.7.1 Equipment sizing. Heating and cooling equipment shall be sized in accordance with ACCA Manual S based on the
equipment loads calculated in accordance with ACCA Manual J or other approved heating and cooling calculation methodologies,
based on building loads for the directional orientation of the building. The manufacturer and model number of the outdoor and
indoor units (if split system) shall be submitted along with the sensible and total cooling capacities at the design conditions
described in Section R302.1. This Code does not allow designer safety factors, provisions for future expansion or other factors that
affect equipment sizing. System sizing calculations shall not include loads created by local intermittent mechanical ventilation such
as standard kitchen and bathroom exhaust systems. New or replacement heating and cooling equipment shall have an efficiency
rating equal to or greater than the minimum required by federal law for the geographic location where the equipment is installed.
TABLE R403.6.1
WHOLE -HOUSE MECHANICAL VENTILATION SYSTEM FAN EFFICACY
FAN LOCATION
AIRFLOW RATE MINIMUM
(CFM)
MINIMUM EFFICACY a
(CFMANATT)
AIRFLOW RATE MAXIMU
(CFM)
Range hoods
Any
2.8 cfm/watt
Any
In -line fan
Any
2.8 cfm/watt
Any
Bathroom, utility room
10
1.4 cfm/watt
<90
Bathroom, utility room
90
2.8 cfm/watt
Any
For SI: 1 cfm = 28.3 Umin. a. When tested in accordance with HVI Standard 916
4/5/2019 9:01 AM EnergyGauge® USA - FBC 6lh Edition (2017) Compliant Software Page 3 of 5
MANDATORY REQUIREMENTS - (Continued)
❑ 11403.7.1.1 Cooling equipment capacity. Cooling only equipment shall be selected so that its total capacity is not less
than the calculated total load but not more than 1.15 times greater than the total load calculated according to the procedure selected in
Section 403.7, or the closest available size provided by the manufacturers product lines. The corresponding latent rapacity of the
equipment shall not be less than the calculated latent load.
The published value for AHRI total capacity is a nominal, rating -test value and shall not be used for equipment sizing. Manufacturer's
expanded performance data shall be used to select cooling -only equipment. This selection shall be based on the outdoor design dry-bulb
temperature for the load calculation (or entering water temperature for water -source equipment), the blower CFM provided by the expanded
performance data, the design value for entering wet -bulb temperature and the design value for entering dry-bulb temperature.
Design values for entering wet -bulb and dry-bulb temperatures shall be for the indoor dry bulb and relative humidity used for the load
calculation and shall be adjusted for return side gains if the return duct(s) is installed in an unconditioned space.
Exceptions:
1. Attached single- and multiple -family residential equipment sizing may be selected so that its cooling capacity is less than the
calculated total sensible load but not less than 80 percent of that load.
2.
When signed and sealed by a Florida -registered engineer, in attached single- and multiple -family units, the capacity of
equipment may be sized in accordance with good design practice.
R403.7.1.2 Heating equipment capacity.
❑ R403.7.1.2.1 Heat pumps. Heat pump sizing shall be based on the cooling requirements as calculated according to Section
R403.7.1.1, and the heat pump total cooling capacity shall not be more than 1.15 times greater than the design cooling load even if
the design heating load is 1.15 times greater than the design cooling load.
❑ R403.7.1.2.2 Electric resistance furnaces. Electric resistance furnaces shall be sized within 4 kW of the design
requirements calculated according to the procedure selected in Section R403.7.1.
❑ R403.7.1.2.3 Fossil fuel heating equipment. The capacity of fossil fuel heating equipment with natural draft atmospheric burners
shall not be less than the design load calculated in accordance with Section R403.7.1.
❑ R403.7.1.3 Extra capacity required for special occasions. Residences requiring excess cooling or heating equipment capacity on an
intermittent basis, such as anticipated additional loads caused by major entertainment events, shall have equipment sized or controlled to
prevent continuous space cooling or heating within that space by one or more of the following options:
1. A separate cooling or heating system is utilized to provide cooling or heating to the major entertainment areas.
2. A variable capacity system sized for optimum performance during base load periods is utilized.
R403.8 Systems serving multiple dwelling units (Mandatory). Systems serving multiple dwelling units shall comply with Sections
❑ C403 and C404 of the IECC—Commercial Provisions in lieu of Section R403.
❑ R403.9 Snow melt and ice system controls (Mandatory) Snow- and toe -melting systems, supplied through energy service to the building,
shall include automatic controls capable of shutting off the system when the pavement temperature is above 50°F (10`C), and no
precipitation is falling and an automatic or manual control that will allow shutoff when the outdoor temperature is above 40°F (4.8°C).
❑ R403.10 Pools and permanent spa energy consumption (Mandatory). The energy consumption of pools and permanent spas
shall be in accordance with Sections R403.10.1 through R403.10.5.
❑ R403.10.1 Heaters. The electric power to heaters shall be controlled by a readily accessible on -off switch that is an
integral part of the heater mounted on the exterior of the heater, or external to and within 3 feet (914 mm) of the heater. Operation
of such switch shall not change the setting of the heater thermostat. Such switches shall be in addition to a circuit breaker for the
power to the heater. Gas -fired heaters shall not be equipped with continuously burning ignition pilots.
❑ R403.10.2 Time switches. Time switches or other control methods that can automatically turn off and on according to a preset schedule
shall be installed for heaters and pump motors. Heaters and pump motors that have built-in time switches shall be in compliance with this
section.
Exceptions: -
1. Where public health standards require 24-hour pump operation.
2. Pumps that operate solar- and waste -heat -recovery pool heating systems.
3. Where pumps are powered exclusively from on -site renewable generation.
R403.10.3 Covers. Outdoor heated swimming pools and outdoor permanent spas shall be equipped with a vapor -retardant cover on or at
❑ the water surface or a liquid cover or other means proven to reduce heat loss.
Exception: Where more than 70 percent of the energy for heating, computed over an operation season, is from site -recovered
energy, such as from a heat pump or solar energy source, covers or other vapor -retardant means shall not be required.
R403.10.4 Gas- and oil -fired pool and spa heaters. All gas- and oil -fired pool and spa heaters shall have a minimum thermal
❑ efficiency of 82 percent for heaters manufactured on or after April 16, 2013, when tested in accordance with ANSI Z 21.56. Pool
heaters fired by natural or LP gas shall not have continuously burning pilot lights.
4/5/2019 9:01 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 4 of 5
❑ R403.10.5 Heat pump pool heaters. Heat pump%pool heaters shall have a minimum COP of 4.0 when tested in accordance
with AHRI 1160, Table 2, Standard Rating Conditions -Low Air Temperature. A test report from an independent laboratory is
required to verify procedure compliance. Geothermal swimming pool heat pumps are not required to meet this standard.
R403.11 Portable spas (MandatoryQhe energy consumption of electric -powered portable spas shall be controlled by the
requirements of APSP-14.
SECTION R404
ELECTRICAL POWER AND LIGHTING SYSTEMS
R404.1 Lighting equipment (Mandatory). Not less than 75 percent of the lamps in permanently installed lighting fixtures shall be
high -efficacy lamps or not less than 75 percent of the permanently installed lighting fixtures shall contain only high -efficacy lamps.
Exception: Low -voltage lighting.
R404.1.1 Lighting equipment (Mandatory). Fuel gas lighting systems shall not have continuously burning pilot lights.
4/5/2019 9:01 AM EnergyGauge® USA - FBC 6th Edition (2017) Compliant Software Page 5 of 5
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: EDGAR RODRIGUEZ Builder Name:
Street: 1910 GEORGIA AVE Permit Office: FT. PIERCE
City, State, Zip: FT PIERCE, FL, Permit Number:
Y
U
Owner: EDGAR RODRIGUEZ Jurisdiction:
w
x
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier.
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in any dropped ceiling/soffit
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within corners and headers of frame walls
The junction of the top plate and the tap of exterior walls shall be
shall be insulated by completely filling the cavity
sealed.
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking, or floor framing cavity insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be cut to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spa
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be air tight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
extend behind piping and wiring
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electrical/phone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
sprinklers
sealed in a manner that is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fire snrinkler cover n1ates and walls or ce linas
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC-400.
4/5/2019 9:01 AM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
Envelope Leakage Test Report (Blower Door Test)
Residential Prescriptive, Performance or ERI Method Compliance
2017 Florida Building Code, Energy Conservation, 6th Edition
Jurisdiction: Permit #:
`� ,��Ff. ,r n �' /4 c txf-,3^,x ,� s. 'A 3" r�'.0,
nP7.as` r ?,`n rz F-4s' yx 1 Yv I`,rR
►bb'in orma£ta i :; T,
e ex Na.. ...... a" .,,t .. z, .
Builder: Community: Lot: NA
Address: 1910 GEORGIA AVE
City: FT PIERCE State: FL Zip:
r;�l`Ir Le:9iC��e T�ESt,I�£SLt1�3- -. Pe`ssmg resuitsrtru5#ittee#ertherthe erfomlance Flescnptrve orERt Method � � t ; -�
=W"�¢ � t t �:) v �
4i' f ?♦� ; !' �f 3's r+,t a I .A° �� � �. N� i :x. °3 $ff.
mJhxa�4vs�4 jg eay',
.caol-1 rwl°6('`5"ni0g e4
F.7gCR�PPestxrrf»I�Vr
�r"MSr1 �i'iaendd,ao��-#'n�ett e"' x.ceai;+b°,erES d�ng7 'aart;.x,vr, g,-.�,a_',
Ta'HPOt€enD
a.` n;a�y��rxte+rt»ark
akspaw„vsllltsayl(rvnb�eC. tli+ems.lae.t,d"era aZnoydg�n,}}
e�,
<a,ig,
2s.,
m,g3
o'E3uPtBrra.ar
exv s�
aEt ss"�uhr#ek`'-:..bbfu,9dd.2` w•ge-
��g�.�s
T.'f°..v',if..^:.rfx.i-b*� �F ✓4� as Y"•, }.w iY4a.k>� a' ....'3�. ... :. 4HF'��. irt'Y } 4� iV -°.� { },,t. ix-x. 'fi"A €�'i�M ;i"T^.p.
R7At Y kiGs ✓'Tt..9 C`x' a^#`i} '� £ h �'6{Y ,2�b ff- 3
__ pERF+3 MANCE.oc ER1 METNDD The bulldmg or wain Glut sha0 pe tested an �,yenfletl as havutg an air teakagefata qr not exceeding
;t7ta seteciad'ACH(50}va4ua asshown ah Form R4f15 20i7 (Perfgrmance) dcR406-2U17 (ERp sachon labeled as}n#iltraho`ri :suti-section ACN5Q§
dn�'orfi f�405-20?7ERa(yy 4.alG (/?e7on1)ande) i7f f?+iD fEl�i} 4.000
- 7�^kGFi{50J sPectFied 203.7
x 60 _ 8864 - Method for caiculating building volume:
CFM(50) Building Volume ACH(50)
Q Retrieved from architectural plans
u PASS • Code software calculated
When ACH(50) is less than. 3, Mechanical Ventilation installation O Field measured and calculated
must be verified by building department.
R402.4.1.2 Testing. Testing shall be conducted in accordance with ANSI/RESNET/ICC 380 and reported at a pressure of 0.2 inch w.g. (50 Pascals)
Testing shall be conducted by either individuals as defined in Section 553.993(5) or (7), Florida Statues.or individuals licensed as set -forth in Section
489.105(3)(f), (g), or (i) or an approved third party. A written report of the results of the test shall be signed by the party conducting the test and
provided to thecode official. Testing shall be performed at any time after creation of all penetrations of the building thermal envelope.
During testing:
1. Exterior windows and doors, fireplace and stove doors shall be closed, but not sealed, beyond the intended weatherstripping or other infiltration
control measures.
2. Dampers including exhaust, intake, makeup air, back draft and flue dampers shall be closed, but not sealed beyond intended infiltration control
measures.
3. Interior doors, if installed at the time of the test, shall be open.
4. Exterior doors for continuous ventilation systems and heat recovery ventilators shall be closed and sealed.
5. Heating and cooling systems, if installed at the time of the test, shall be turned off.
6. Supply and return if installed at the time of the test, shall be fully open.
iregisters,
g.
TestmgrCb6tpany ih �g tx c r
i .'`f..�yv.... _�Ln.9�.P. �. _.sY' r: `.ttY_e'ro v.-_.a:.. fir.;..i> �£ :.x�`.•.�._#{
Company Name: Phone:
I hereby verify that the above Air Leakage results are in accordance with the 2017 6th Edition Florida Building Code
Energy Conservation requirements according to the compliance method selected above.
Signature of Tester: Date of Test:
Printed Name of Tester: I
License/Certification #: Issuing Authority:
4/5/2019 9:01:37 AM EnergyGauge® USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
y.:
Edgar Rodriguez
HVAC Load Calculations
for
Edgar Rodriguez
1910 Georgia Ave Apt B
Fort Pierce, FI. 34950
loom�.-.
Prepared By:
Robert Weidman
Preferred Air Conditioning & Mechanical
1643 Donna Road
West Palm Beach, FI. 33409
5116-689-1093
Friday, April 05, 2019
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
Rhvac - Residential & Light Commercial HVAC Loads - _ "
Preferred Air Conditioning & Mach
Elite Software 6evelopment, Inca
Edgar Rodriguez:
__ -
West Palm Beach, FL =33409
_ _..
Project Report
General
Peoject1nf6rration
Project Title: Edgar Rodriguez
Designed By: Robert Weidman
Project Date: 04-01-2019
Client Name: Edgar Rodriguez
Client Address: 1910 Georgia Ave Apt B
Client City: Fort Pierce, Fl. 34950
Company Name: Preferred Air Conditioning & Mechanical
Company Representative: Robert Weidman
Company Address: 1643 Donna Road
Company City: West Palm Beach, FI. 33409
Company Phone: 5116-689-1093
Company Fax: 561- 478 - 0089
Company E-Mail Address: @preferredacmech.com
Company Website: getcold.net
Company Comment:
Design Data
Reference City: Fort Pierce, Florida
Building Orientation: Front door faces South
Daily Temperature Ranger Medium
Latitude: 27 Degrees
Elevation: 25 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor
Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb
Difference
Winter: 42 39.4 n/a n/a 72
n/a
Summer: 90 78 59% 50% 75
61
Check figures. _ = ===
Total Building Supply CFM: 969 CFM Per Square ft.:
1.072
Square ft. of Room Area: 904 Square ft. Per Ton:
400
Volume (ft3): 7,232
Total Heating Required Including Ventilation Air: 16,433 Btuh 16.433
MBH
Total Sensible Gain: 22,116 Btuh 81
%
Total Latent Gain: 5,024 Btuh 19
%
Total Cooling Required Including Ventilation Air: 27,140 Btuh 2.26
Tons (Based On Sensible + Latent)
Notes
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual
D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\EDGAR RODRIGUEZ.rh9 Friday, April 05, 2019, 9:00 AM
Rhvac - Residential & Light Commercial HVAC Loads
Preferred Air. Condifioning & Mech
_ .;
+
- _
Elite
Software Development, Inc.,
,Edgar Rodriguez
_
`West Palm Beach FL ob
-
_ _
_
_
Load Preview Report
Has
Nel! R'
Sen
Lat
iNetSen
Min
Htg
Min
Clg
Sys
Htg
Sys
Cig
Sys
Act
_
Ducl
Scope
AED
Toni Iron
Area
Gain
Gain
GLoss
CFM
CFM
CFM
CFM,
CFM
Size
Building
2.26 400
904
22,116
5,024
27,140
16,433
192
969
192
969
969
System 1 Main Floor Yes
2.26 400
904
22,116
5,024
27,140
16,433
192
969
192
.,_ 969
969
11x16
Ventilabon
824
2,075
2,899
1,649
Zone 1
904
21,292
2,949
24,240
14,785
192
969
192
969
969
11x16
1-Kitchen
144
3,947
1,097
5,044
2,563
33
180
33:
`180
180
1-8
2-Bath Room
45
1,079
291
1,369
1,529
20
49
20
_ _ 4,91
49
1-4
3-Bedroom 1
180
3,742
751
4,492
2.050
27
170
27
": 170
-221,
170
1-8
4-Bedroom2
192
4,864
230
5,094
2,407
31
221
31
221
1-9
5-Living
252
5,095
291
5,386
2,249
29
232
29
_232
232
1-9
6-Entry
91
2,564
291
2,855
3,988
52
117
52, 117
117
1-6
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\EDGAR RODRIGUEZ.rh9 Friday, April 05, 2019, 9:00 AM
R,bvac REsident1a18'Light m Comercial HVAC
Loads '� ,
.�- �
��,�,« , .;� �*} "'
o: - s
Elde Sofware Development,
lnc
EdgatRodriguez j
VSiesfPal F1'Seach FL 334a9
"` r
� r
Paak
Duct Size Preview
Room or
Source j
Minimum;
Maximum
Rough.
Design
SP
Duct
Duct
Htg
Clg j
Act. Duct
Duct Name
y
Velocity!Velocty
Factor]
L/100
Loss
Velocity
Length
Flow
Flow i- Size
_
System 1
_Flow)
Supply Runouts
Zone 1
1-Kitchen
Built -In
450
750
0.01
0.1
514.6
33 .. fig:
180 1-8
2-Bath Room
Built -In
450
750
0.01
0.1
562.4
20?`j9,'
49 1-4
3-Bedroom 1
Built -In
450
750
0.01
0.1
487.7
27 6,1701
170 1-8
4-Bedroom2
Built -In
450
750
0.01
0.1
501
3153j
221 1-9
5-Living
Built -In
450
750
0.01
0.1
524.7
29pk,.�w..2,iy 2
232 1-9
6-Entry
Built -In
450
760
0.01
0.1
594.2
52 @.,au x7�"
117 1-6
Other Ducts in System 1
Supply Main Trunk
Built -In
650
900
0.003
0.1
792.6
1927
969 11xi6
Summary
System 1
Heating Flow. 192
Cooling Flow: 969
J
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\EDGAR RODRIGUEZ.rh9 Friday, April 05, 2019, 9:00 AM
Rhvac Res�dent�a[ 8 LightCommercial HVAC Loads x f Ar , : t Elite Software De3elopment lnc ;
Cpndi6om +�"�" r= Edgar Rodaguez
PP@felred AR S Mech
VJeitPalhi Beach-FL'331b9 m' a r; x
aPa9e 5
System 1 Main Floor Summary Loads
Ggrr�pofierlt ;
w ' r `z x , Cat Sett xotal
:
0t i 43tv3 'F M"b^, hlu.,
tD scripUowj�=
k e S4 T' M1 } Fit
�. Irt �....: ain'
.� _
New Material: Glazing-SHG STD, U-value 0.96, SHGC 123 3,543
.
0 3,783 3,783
0.48
New Material: Glazing-SHG STD, U-value 0.96, SHGC 108.6 3,127
0 5,752 5,752
0.48
11 J: Door -Metal - Fiberglass Core, U-value 0.6 19.8 356
0 309 309
STUCCO BLOCK R-4.1: Wall -Custom, BLOCK4.1, U- 724.6 2,586
0 1,147 1,147
value 0.119
16B-30: Roof/Ceiling-Under Attic with Insulation on Attic 892 855
0 1,427 1,427
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark
Asphalt Shingles or Dark Metal, Tar and Gravel or
Membrane, R-30 insulation, U-value 0.032
22A-ph: Floor -Slab on grade, No edge insulation, no 56 2,282
0 0 0
insulation below floor, any floor cover, passive, heavy
moist soil, U-value 1.358
20P-19: Floor -Over open crawl space or garage, Passive, 588 882
0, 294 294
R-19 blanket insulation, cover, U-value 0.05
Subtotals for structure: 13,631
0 12,712 12,712
People: 3
690 900 1,590
Equipment:
806 7,072 7,878
Lighting: 9
31 31
Ductwork: 0
0 0 0
Infiltration: Winter CFM: 35, Summer CFM: 35 1,154
1,453 577 2,030
Ventilation: Winter CFM: 50, Summer CFM: 50 1,649
2,075 824 2,899
System 1 Main Floor Load Totals: 16,433
5,024 22,116 27,140.
14 GhecK f` UCeS b* t; s i r 2= a� i '` t des
Supply CFM: 969 CFM Per Square ft.:
1.072
Square ft. of Room Area: 904 Square ft. Per Ton:
400
Volume (W): 7,232
5ystefrl'Loatis _
Total Heating Required Including Ventilation Air: 16,433 Btuh 16.433 MBH
Total Sensible Gain: 22,116 Btuh 81 %
Total Latent Gain: 5,024 Btuh 19 %
Total Cooling Required Including Ventilation Air: 27,140 Btuh 2.26 Tons
(Based On Sensible + Latent)
_w„ ,A :,,.AY
Rhvac is an ACCA approved Manual J, D and S computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\EDGAR RODRIGUEZ.rh9 Friday, April 05, 2019, 9:00 AM
Cooling
System Type:
Outdoor Model:
Indoor Model:
Tradename:
Outdoor Manufacturer:
AHRI Reference No.:
Capacity:
Efficiency:
Standard Air Conditioner
CA16NA030*0**A*
FX4DN(B,F)037L
16 SEER AC
CARRIER
9198746
29,400
16 SEER
C:\Users\EngDept\Documents\Elite Software\Rhvac 9 Projects\EDGAR RODRIGUEZ.rh9 Friday, April 05, 2019, 9:00 AM