HomeMy WebLinkAboutTRUSS PAPERWORKA =LIFE SAFETY WARNING
This symbol identifies Life Safety Warnings that
should be read and given special attention to all
persons installing trusses.
SPACING NOTE
All trusses are to be set 2'-0" on
center except as noted.
MULTIPLE PLY TRUSSES MUST BE FASTENED
TOGETHER PER ENGINEERING BEFORE
SETTING. REFER TO ENGINEERING DRAWING
TO DETERMINE IF MULTIPLE PLY.
I
DON'T LIFT TRUSSES
WITH SPANS LONGER THAN
30' BY THE PEAK.
CONSULT BCSI
30' Soln or less
60 degrees
or less
Tag lino � 112 ,an --o Teg lino �j�p of Span
approx.
REFER TO BCSI REFER TO BCSI
Truss must be set this way if crane is used. Truss must be set this way if crane is used.
Truss is an example, your truss may not match. Truss is an example, your truss may not match.
insist crane operator sets truss this way. Insist crane operator sets Huss this way.
All load bearing walls, headers,
beams, & lintels must be in place
at indicated hei ht before trusses
A Do not stand on
trusses
until they are braced per BCSI
&
properly nailed to straps
and hangers !!
QARRANGE WITH
CRANE
OPERATOR IN ADVANCE FOR
A
STRONG BACK OF 41' -
46' IN LENGTH!!
REPR ESENTS A HANGER
HANGER SCHEDULE
USE HUS26 FOR 2X4 SUH46 FOR 4X2 EXCEPT AS SHOWN
'CARRIED CARRYING
TRUSS TRUSS
7
FASTENER FOR
CARRIED TRUSS
FASTENER FOR
CARRYING TRUSS
I
I
FGA,GFB I CARRIER
THD26-2
12-10d
18-16d
*Please refer to Standard Engineering package for general instuction on installing hangers
10d=0.148" x 3" 16d=0.162" x 3 1/2"
g
are installed.
I
AIR HANDLER NOTE
Unless noted elsewhere on this layout, these trusses are not
designed for air handlers in the roof or for any other A/C
requirements. This may be in conflict with building code and A/C
Design requirements. Consult with Building Department and A/C
Contractor.
Zh WARNING !
The size of these trusses makes it necessary that they a set by a profeesional builder
familiar with and experienced in the problems and dangers of setting large span trusses.
The builder and erector should consult with an engineer licensed in Florida specializing
in wood roof trusses about the safe erection of these trusses. The engineer should be at
the job site when trusses are erected to provide supervision and advice.
SEAT PLATES BY CHAMBERS TRUSS
BONUS ROOM
Hatch
Legend
WALL
HEIGHT 18'-11"
WALL
HEIGHT 12'-0t,
WALL
HEIGHT 13'-411 T
WALL
HEIGHT 9'4"
12
f 6
4-03 `
Q PLUMB CUT END
2X4 TOP CHORD
WALL HEIGHT 9'-4" & 18'-11"
END DETAIL: TYPICAL
HIP CARRIER LOCATED AS DIMENSIONED ON LAYOUT
I
CORNDER JACKS
ARE NOT BEVELED.
SEE STANDARD
ENGINEERING.
i III \\
r
T I I
24" O.C. THRU
CORNER JACKS
ONLY - 24"
_ 7' 1-11
CORNER DETAIL
OVERHANGS NOT SHOWN FOR CLARITY
N
FABRICATION AGREEMENT
TRUSSES CANNOT BE STARTED UNTIL THIS AGREEMENT IS SIGNED & RETURNED.
he undersigned acknowledges and agrees:
1. Trusses will be made in strict accordance with this truss placement diagram layout, which is the sole authority for li
Aerminmg successful fabrication of the trusses.
2. All dimensions in this layout have been verged by the undersigned.
3. Unless written notice Is provided by certified mail to Chambers Truss within ten (10) days of delivery the
ldersigned agrees that no backcharges will be allowed. In the event such written notice is furnished Chambers Truss
tall have three (3) business days In which to begin repairs required, or to substitute other trusses, at Chambers option.
Iter 10 days of delivery remedy will be according to Florida statute 558.
4. The undersigned acknowle
dges es receipt of "BCSI' summary sheet b TPI & WTC .
9 A 9 P rY Y
5. Delivery is to job site. It is the buyer's responsibility to make the job site suitable for delivery. Chambers Truss has
e sole authority to determine the suitability of the job site or a portion of the job site for delivery. Chambers Truss will I
responsible for dump delivery only. The buyer is responsible for additional delivery expenses if Chambers Truss has
redeliver because job site is not prepared for delivery or buyer is not prepared for delivery of trusses. Buyer is
sponsible to Chambers Truss for towing costs due to site conditions,
6. Price as shown in paragraph 7 below is subject to change if any changes are made in this layout. A $50 per hour
e for revisions may be charged by Chambers Truss.
7. This is a PURCHASE ORDER to Chambers Truss of the sum agreed to, or if no agreement a reasonable price.
voice will be made on delivery and paid within terms of net on delivery. Invoice may be made at scheduled date of
Slivery if buyer cannot accept delivery of fabricated trusses. The undersigned agrees to pay Chambers Truss
Tasonable attorney's fee for collections in event of payment not timely made. 1-112 % per month service charge will be
ided for all sums not paid within terms.
8. Signature or initials anywhere on this sheet constitutes agreement to all terms herein.
9. In consideration of Chambers Truss extending credit for this material the undersigned Unconditionally guarantees
ayment when due of any and all indebtedness owed to Chambers Truss by any entity receiving material and the
ldersigned agrees to pay such indebtedness including attorney's fees, If default in payment for material be made by the
cipient.
10. In the event of any litigation concerning this agreement, the items furnished hereunder or payments referred to
rein, the parties agree that the sole venue for any such action will be Saint Lucie County, Florida.
11. Design responsibilities are per ""National Standard And Recommended Guidelines On Responsibilities For
onstruction Using Metal Plate Connected Wood Trusses ANSI/TPIIWTCA 4 - 2002""
12. Warranty is per Chambers Truss Warranty attached.
A spreader bar may be required per to prevent injury & damage.
I
Multiple ply trusses must be fastened together per engineering before they are
set, failure to do so can result in roof collapse.
Temporary and permanent bracing arerequired and can save life and property
and is the responsibility of the truss erector.
Study the contents of the information packet included on delivery before
setting trusses.
.s
Trusses must be set and braced per design to prevent injury & damage. j
I
Trusses must be set Iumb and square
Do not set bunks or stack of plywood, roofing material or any other
- concentrated loads on trusses, this can cause collapse.
DO NOT INSTALL TRUSSES USING THIS
USE PLAN DELIVERED WITH TRUSSES TO SET TRUSSES
CHAMBERS TRUSS INC
e4go k,
3105 Oleander Avenue
Fort Pierce, Florida 34982.6423
800.551-5932
Fort Pierce 772-465.2012 Fax 772.465-8711
Vero Beach 772.569.2012 Stuart 772.286-3302
Web Site: CHAMBERSTRUSS.COM
Email: MAIL@CHAMBERSTRUSS.COM
ER ON7N 7.4. 1.431—
LOADINGIDESIGN CRITERIA REDUCIBLE
DESIGN CRITERIA
PER CODE SUCH AS SBC 1604.6.1
County
ST. LUCIE CO.
!
Building Department
PORT ST, LUCIE
Wind Design Criteria
ASCE 2010
Wind Design Method
MWFRS(Directional)/C-C hybrid Wind ASCE 7-10
Roofing Material
Shingle or Shake
Loading in PSF
Roof R.D.L.
Floor
Top Chord Live
20
40
Top Chord Dead
7 4.2
10
Bottom Chord Live
*10-Non Conccurent
0
Bottom Chord Dead
10 3
5
Total Load
47 7.2
55
Duration Factor
1.25
1.0 !
Wind Speed
160mph
Top Chord C.B.
Sheathing by builder
Bottom Chord C.B.
Sheathing by builder
Highest Mean Height
15'
T
Building Type
Enclosed
Building Category
It: Non Restrictive
Exposure Category
C>Open Terrain with scattered obstructions
Miles from Ocean
5
Conforms to Florida Building Code 2017
R.D.L =Restraining Dead Load
C.B.=Continuous Bracing
Verify DESIGN CRITERIA shown above with the j
building department and your engineer.
Design Criteria is the responsibility of the
Building Designer and/or Engineer of Record
Chambers Truss Inc. Drawing Name: 75842
SCALE: 1/4 91 = 1'-011
208 total trusses, 72 unique designs
i Designer: RAC Reviewed by:
Date: 03/07/19
FOR SCANNED'
BY
RO N RAYM O N D St. Lucie Count
DESCRIPTION: 19Qy_�IC��
j WEINERT /
Page 1 of 1 CUSTOMER INITIALS EACH PAGE
75842�.() Py