Loading...
HomeMy WebLinkAboutSURVEYSSite Bene Mark El. NAVD 1 1 PKDF'pCP eWi 0 0 z 1 X in Se war-""--- Manhole LEGAL DESCRIPTION Unit 24, MARINER VILLAGE, HARBOUR RIDGE, PLAT NO.4, according to the Plat thereof, as recorded in Plat Book 24, Pages 19, 19A through 19D, Public Records of St. Lucie County, Florida. PREPARED FOR: Mark Witoczck and Cathy Witaczack Prepared By: Regina C. Kamer, PSM#4363 Kamer Surveying, Inc. LB#7357 Prepared For: Mark and Cathy Witaczack MIN. SETBACK REQ. FRONT SIDES � 2r1 �1\�S CNR SIurS REAR ZNG. 42 TECH. SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal. 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 3.26.2019. 4 This Survey was prepared using the Plat of Record, no search of the public records was performed by this office. 5 This Survey shown hereon was prepared in accordance with the Standards of the practice of Surveying and Mapping as defined in 5J— 1 7.050-052FAC. 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Bearings have been based on the North Line of the Subject Property as shown hereon. All other bearings are relative thereto. 8 Parcel/Lot line locations have been based on found survey control along the center line and/or right of way line of NW Mariner Court. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined as part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 Elevations shown hereon are in accordance with the North American Vertical Datum of 1988. FEMA Flood Zone data shown here on is based on the visual inspection of the digital Flood Hazardous Maps provided by the Federal Emergency Management .Agen:w (FEMA) and is limited to the accurr_cy of such maps. Flood Zone: X Community #: 120285, Panel #: 0131, Suffix: J, Date: 2.16.2012 LEGEND C - Concrete LEGEND CIE -Covered Entry CAC - Concrete Pad with Air Conditioning ACM - Found 4 concrete Monument CS - Catch Basin FIP - Found }' Iron Pipe CBS — Concrete Block structure FPC - Found * Aron Pipe with Cap CUP - Corrugated Metal Ppe CPE Concrete Pad Paul Equipment FIR - Fond 15 Iron Rod - with CN - CableTV Box nRC - Found 15 Aron Rod with Cap FFE - FlFloor Ebvahon SIRC - Set 15 iron Rod with Cap W7357' CV -WaterGate Valve FA°C - Found 1/2' iron Pipe with Cap HYDW - Flre to d FM -Found Ma Nail FWD - NmT Olak Utility 0JL Overhead Utility l.Me with - Power Pab Found aff FN - Fo Noi( SS - Sanitary Sewer Manhole FNTT -Found Nail with Rn Tab ou MR - Telephone, Communicotiornn Box FPK -Found Pit Nail US US - UBtity Box FPKD - FcwM Pit Nail with Disk ,yty FRRS -Found Rail Road Spike /CO - In Povement Cut Out KARNER SURVEYING, INC. Residential & Commercial Surveying Services 2740 SW Martin Downs Blvd.#333, Palm City, F1.34990 Phone: (772)288 7206 Fax:(772)223 8181 WWW.KARNERSURVEYINGINC.COM karner0comcasf.net M 1 SCANNED BY St. Lucie County ,m1aa L -a7 E � � I I I I I I 0� Fl 30.0 - 0" - 1 A0 � µ0 Site Bench N b y Mark El. 8.5�s a m II 9 II r � O I �y r , ai I hni 3o 1 61 f I Radius=750.00' r-^Delta=29'4Y'26" Length=388.65' Chord=N14*50'43"W hord Length=384.31' I l 1 PKDF"pCp 0 kul z ! X in Sewer".,-.._._,_.,_ Manhole 0 LEGAL DESCRIPTION Unit 24, MARINER VILLAGE, HARBOUR RIDGE, PLAT NO.4, according to the Plat thereof, as recorded in Plat Book -24, Pages 19, 19A through 19D, Public Records of St. Lucie County, Florida. ^22'14"E FIRL83881 39.44' 0.12' --------72.8--------- _J" �'.':•---,.--_.--�_._ � `''mow ,,,,, �.� i S65"00'00,, 70.55 F/RC LB3887 0. 14%v f 1 02 'N F 3 p,10 15 �N s> a, `p pock 150 t e3 Y �V- 'g SIRC m YTm kip O A- Q 4 N a y. W .W 001 t to1-' 8 f J\ pe Pmeftocesd o J?`�'9 0\-1- 1,R N c,gtp -- s4 e'' 134 61 S34a pro PREPARED FOR: Mark Witaczck and Cathy Witaczack Prepared By: Regina C. Kamer, PSM#4363 Kamer Surveying, Inc. LB#7357 Prepared For: Mark and Cathy Witaczack SIRC t O " I FIRC LB3881 n 17'N 0.13'W MIN, FRONT SIDES_ CNR Si A REQ. SURVEYOR'S REPORT 1 This Survey shall not be valid unless sealed with an embossed Surveyor's Seal. 2 No underground improvements have been located as part of this Survey. 3 The last field date of this Survey was: 3.26.2019. 4 This Survey was prepared using the Plat of Record, no search of the public records was performed by this office. 5 This Survey shown hereon was prepared in accordance with the Standards of the practice of Surveying and Mapping as defined in 5J-17.050-052FAC. 6 By acceptance of this survey all parties agree that the signing surveyor's liability is limited to the amount paid for said Survey. 7 Bearings have been based on the North Line of the Subject Property as shown hereon. All other bearings are relative thereto. 8 Parcel/Lot line locations have been based on found survey control along the center line and/or right of way line of NW Mariner Court. 9 LEFT BLANK. 10 The Legal Description shown hereon was provided by the client and/or his/her representatives. 11 No ownership of fence lines has been determined as part of this Survey. 12 Off set calls to found survey control are relative to the nearest property corner, intersection of lines, point of curvatures (PC), point of reverse curvatures (PRC) or other identifiable point. 13 Compliance with local zoning requirements and or with requirements set forth by other State, Public, and/or Private entities has not been verified as part of this Survey. 14 Elevations shown hereon are in accordance with the North American Vertical Datum of 1988. FEW Flood Zone data shown here on is based on the visual inspection of the digital Flood Hazardous Maps provided by the Federal Emergency --- -- --- Mct y^ero, -�P,s fancy (TEIWAj- rd-Is - lirr hm� to the accuracy of such maps. -. Flood Zone: X Community pi: 120285, Panel J: 0131, Suffix: J, Date: 2.16.2012 un 4:5 LEGEND C — Cormrets CIE — Covered Entry CM: — Corwrwts Pad with Air Conditioning co — Catch Born CBS. — Concrete Block Structure CMP — Corrugated Metal PI CPE — Concrete Pod with Pool Equipment C1V — Cable 7V Saw FFE — Finlehed Floor Eimilan Gv — Water Cate vow HW — Are Hydrant 0/1 — Overhead th011y Line PP — Power Palo SSMH — Switary Sewer Manhole TCS — Telephone Communkatinne Bev us — utigty Bax WM — water Meter LEGEND FCM — Found 4'k4 Gowete Monument nP — Found }' Iran pipe FIPC — Found iron Pipe with Cap AR — Found ir iron Rod ARC — Found 15 ban Rod with Cap SIRC — Set 15 Iron Rod with Cap tV7357` nPC — Found 112' Iron Pipe with Cap FM — Found Mag Nail FMD — Found all Nag with Mk FN — Found Nail FNTT — Found Nag with Tin Tab FPK — Found PK Nail FPKD — Found PK Nag with Disk FRO — Found Rag Road Spike /CO — in Pavement Cut Out SCANNED BY St. Lucie County 4. a'