Loading...
HomeMy WebLinkAboutPOOL SPECIFICATIONSSPA DETAIL APPROVED MAIN DRAIN FRAMES AND GRATES PER V.G.B. ASME/ANSI 112.19.8-2007 APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR ' RESIDENTIAL 6TH EDITION AND THE ANSBAPSP-7 2006 FOR SUCTION ENTRAPMENT AVOIDANCE RETURN LINES FOR SPA 2.5" ' TO FIRST TEE UNBLOCKABLE CHANNEL DRAIN v ' • ' • i S FPS MAX ' 3" PLUMBING 3" SUCTION LINE TO LINES FROMt3USUCTION LINE TO PUMP MAX 181 G.P.M. SUMP W/ 3" TEEP MAX 181 G.P.M. ------------- Erillr•rr�r 3�•e7'.I���OEM tea__ . =hniii- 111M�e �-�-----ae.-E- 1al =E aaaa:a_�Ige=_ I: E»IN mill 'mom BULL NOSE FLUSH SPA BRICK CGPIP DETAIL 6"X6" TILT (I) CHANNEL SPA BENCH DRAIN AND 18" BELO GRATE SHALL WATER LINE BE SECURED IN PLACE SO THAT TOOLS ARE REQUIRED V TYP. SPA WALL SECTION (NO SCALE) TRAVERTINE PATIO 41/2" TYP. WALL STEEL-TEX FORM R KRAFT WALL #3 0-12" O.C.B.W. CERTIFICATE OF COMPLIANCE Ilre IUMcwuJ wotl-lureb r Nr.N I. ANSV.PSV 11 NNI pr S rr I1M.X IIw.19 GnmetlMn Wol antl SrMyK1Ktl Z0.191aN silelyrryWafrnrssel bNr Oy I1e CP5L m"e w"arrm are marrmamraa ey uamrr MWeetl vrw.m Ilk to svyim, m'�dd am nvIANIryI 16M)rilerfIM0l.1.INbN INk. ImlenalllgFwaA$uiM e0.Bred G924.1 IIIIL' ]Ii )i3 ]YUI nr IPPMO NAI UA al 5(pl ! PNreaAyMa SVeet OMai, G 91761 II"�9-arz-deg. A<cp/ul lNe leslreWbma/MIouMAwnarlmm urwdw.yH.laDnnw.wg. ���� TUIJM EWIDE3� u O.reaLAualr.nuNe A CIISIOMM(tlDlNN10V.ILISlfi lIINNYJGPWJ; NkWNAµW3NMSVNiW(M VCQM CLEAR SALT HEAT PUMP WITH (3) #6 CU & (1) #10 CU GROUND IN 1" CONDUIT 2HP JANDY PLUS HP PUMP MOTOR W/ POOL PANEL W/ 80 AMP BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CU BRKR & (3)-#4 & (1) #10 GND WITHIN /a" MIN. CONDUIT THHN CU IN 11/4 " RPVC CONDUIT / MANUAL MOTOR SWITCH #8 SOLID CU GROUND WIRE \\�I TO EXIF"'�' 4NEL VARIABLE SPEED FLOPRO PUMP MOTOR W/BUILT-IN OVERLOAD SWITCH W/3- #10 THHN CONDUIT S.P.S. T. TOGGLE TIME CLOCK CU WITH -IN 1/:" SWITCH -' P. DISCONNECT (5) PUOL LIGHTS (GFI NOT REQUIRED) PUMP BONDED BACK TO POOL (1) SPA LIGHT (GFI NOT REQUIRED) 1. ALL ELECTRICAL TO COMPLY WITH 2O14 NATIONAL ELECTRIC CODE. 2.3412 THHN CU WITHIN %" MIN. CONDUIT FOR POOL LIGHT (S) 3. GROUND ALL BOXES, LIGHTS, MOTORS, ETC, WITH #8 SOLID, BARE COPPER. 4. PROVIDE W.P.G.F.I.OUTLET 10' MIN. -20' MAX. FROM WATER'S EDGE. S. ALL POOL PUMPS TO GFCI PROTECTED PER NEC 680.22 (B) ELECTRICAL DIAGRAM N.T.S. RAY REINHARD PE # 47041 1010 EASTER LILLY LN, VERO BEACH, FL ® v O q t D F E, 3 2 EQUIPMENT LAYOUT LEGEND e 7 N.T.S. 1. 2.5" RETURN TO JETS 2.3" SPA MAIN DRAIN LINE 3.3" SPA MAIN DRAIN LINE 4. 2" VACUUM LINE 6. 3" MAIN DRAIN LINE 6.2" SKIMMER 7.2.5" POOL RETURN LINE S. 2.5" SPA RETURN LINE A. JANDY VARIABLE SPEED WIAPPR HAIR & LINT STRAINER B. 1.5" TO WASTE OR TO GROUND C. CARTRIDGE FILTER W/PRESSURE GAUGE AND AIR RELIEF VALVE D. JANDY TRUE CLEAR SALT SYSTEM E. AQUACAL T115 HEAT PUMP F. VALVES (TYP) G. JANDY 2HP JET PUMP WITH APPR. HAIR & LINT STRAINER H. INSTALL PERMA-CAST WATER BOND OR APPROVED EQUAL TIED TO PUMP GROUND W/ #8 SOLID COPPER & APPROVED LUG (MIN. 9 SO. IN SURFACE AREA EXPOSED TO WATER) PER MFGWS SPECS (FIELD VERIFY LOCATION) SWIMOUTS WHEN PROVIDED SHALL BE AT 20" MAX. BELOW THE WATERLINE 20II' max. rN18" I .T.S. Per F.R.C. 4501.18 AND ANSI/ NSPI-5-2003 POOLBOND PB-2008 DECK WATER GRID LOCATION OF WATER BOND_ FOOTER DETAIL (2) #5 REBAR) 12" o+/ o 12" NO SCALE Jandy Pro Series VS FloPro Series Pump VS-FHP2.0 Performance Curves I00 43 90 39 60 35 70 w e a R � eo ze 6 e 3 59 u w' 40 17 TT3 S 30 3 n° 10 I I 4 fi00 m 0 0 POOL DETAIL APPROVED WITH THE 2017 ILDRIG CODE FOR RESIDENTU\L AND THE ANSIIAPS�P-B4006 FOR SUCTION ENTRAPMENTAVOIDANCE APPROVED MAIN DRAW FRAMES AND GRATES PER V.G.B. ASME✓ ANSI 112a9.o-2007 MINIMUM (21 SUCTION LINES PER PUMP 3 FT. SEPARATION OR SEPARATE _P_ LANES 3 FT. MIN. • 2.5" LINE TO FIRST TEE. 1.5" TO POOL II r PLUMBING LINES FRO SUMP W/3"TEE r SUCTION LINE MAX 181 G.P.M. TO FILTRATON PUMP 6 PPS MAX MM 18" MIN. ENTIRE PERIMETER) W.4 SOIL #6 SOUD COP R - BOND WIRE W/ APPR. CLAMPS (ONE ON EACH 8 GAUGE SOLID COPPER WIRB:`- SIDE OF POOL 4 TOTAL) EOUIPOTENTUIL BONDING GRID DETAIL MINIMUM 18" MAX 24" FROM EDGE OF POOL AROUND PER N.E.C. MM SEC. 60126 ENTIRE POOL PERIMETER DVHEREADOPTED) BURIED 4"TO B"DEEP M15G. ryV I W 1. ALL STEPS AND SWIMOUT BENCH EDGES WILL HAVE 2X6 CAP TILE BORDER OF OPPOSITE COLOR OF GEM FINISH FOR VISIBILITY 2. HAND HOLD TO BE INSTALLED AT ARE WHERE DECK RAISED -6- ABOVE POOL7. _ #B GROUND HANDRAIL BONDING WIRE DETAIL WHERE APPLICABLE PER NATIONAL 48„ MAX STEPS1 ELECTRICALCODE WATER Hd• M DEPTH I STEP QUAIL T 1. TREAD IS MIN. OF IW VADE. 1r L RISER NOT GREATER THAN fr M " EXCEPTIF MORE THAN (3) TREADS ARE USED. 3. ALL STEPS TO BE SOLID GUNITE 4000 PSI. N.T.S. OUTSIDE ANGLE OF REPOSE 6' AND FURTHER= 4' THICK WALLS WIN REBAR @ 12' O.C. EACH WAY 3- TO 6' = e" THICK WALLS WIN REBAR it O.C. EACH WAY 0' TO 3' = r THICK WALLS WM3 REBAR @ 1r O.C. EACH WAY k • - D 1. 3R i N N 40 m 0 J / z EXCAVATION INTO THE ANGLE OF REPOSE IS ALLOWABLE PROVIDED: ' SHORING IS INSTALLED AT EXCAVATION AND SHORING SHOULD BE SUFFICIENT TO SECURE SOILS FROM EROSION OR SETTLEMENT '.NO UNDERMINING OCCURS OR ENGINEER APPROVED IF ANY DOES COMPACTION TEST OF THE 13ACKFILLED MARTIAL ARE PROVIDED AT C.O. OF THE SWIMMING POOL 0 10 20 30 40 50 60 70 80 N IN 110 120 iW 140 IM 160 170 180 IN 200 SCHEMATIC MUST HOLD 35 PSI FOR AT (NO SCALE) (�{-EAST 30 MIN, FILTER [2) SEPARATE DRAINS 36" HAIR & LIN' CATCHER )ONENT OF POOL PUMP WATER LEVEL = - FROM Z 1" LIGHT POWER :ONDUIT SUPPLY NDERWATE UNDERWATER LIGH NO LIGHT_ DETAIL j NICHE (NO SCALE) y PPROVED GROUND CLAMP CONTINUOUS BOND WIRE COMMON TO POOL STEEL, POOL FINISH RAILS & EQUIPMENT TRAVERTINE NO1E:: REMOVE GRATE& FROM WELL POINT PLUG FROM MAIN WELL BRX SATTACH PUMP LINE WHEN EMPTYING POOL 6"X6" TILE r • PAVER PO PATIO INTERIOR GRATE SHALL FINISH TYPICAL WALL BE SECURED IN SECTION 8e PLACE SO WELL POINT THAT TOOLS ARE REQUIRED INO SCALE) FOR REMOVAL STEEL-TEX FORM R KRAFT WALL #3 @ 12" O.C.B.W. NOTE: FOR DEPTHS THREADE REATER THAN 6' ADD 1- PLUG #3 COVE BAR @ 6" O.C. TO PUMP -0 GRAVEL BED 1 ROW OF WATERLINE STEEL 12" O/C E.W. FLOOR SLOPE FLOOR SLOPES SHALL BE REASONABLY UNIFORM AND COMPLY WITH ARTICLES 5.6.1 THRU 5.6.3 CYCOLAC MAIN DI �1 THE SLOPE OF THE FLOOR FROM "� THE SHALLOW END WALL TOWARDS THE DEEP AREA SHALL NOT EXCEED 1 FOOT IN 7 TYPICAL SECTION THRU POOL (NO SCALE) -.- w.l"w,nmwlw�vAuw, '.. 640-1BXXV wanrvl./aam mresvemmpAmmNe krm (nrcume5aferyPrtEw comm"Irm"amr.m.,m tt15L3. unm.oe ¢mnao,m a.ree to wx1 awaaaare W tlrerryunmrmisd/5MEP11 ).19&Nq]mJA3MG11119RbYB MEefiree �1d mEKCkn"aald w,alAloN. rnlnmwwanwNreRkam"mesxr. ]9MEIrtyn011NVhxp.Srrl¢1N.BrN.G9K11bR9. WHIvw"AP1311aV¢aarO.vsaMhmreua[dN1i'4t O wA,e ■ �. a W, a E"dA.ay ❑.N9. In1.v4wwmunMmYw.mamrio. Y-®y.4v.,mmYrree.Tea4"ulm4. SCREENED ENCLOSURE THROUGH PIONEER POOL BARRIER PER FRC 4501.17-41.1.17.3 AND ANSIINSPI-5-1995 NSF CERTIFIED TO ASTM F 2208-08 SAFETY BARRIER PER FRC 4101.17-4501.17.1.15 & ASTM6034-95, ASTM D3787-89, ASTM 653-96 'LOCATION OF GFI RECEPTACLE TO BE DETERMINED IN FIELD PER NEC 680 VERIFY EXACT LOCATION IN FIELD WITH SUPERVISOR EQ.LAYOUT (NO -SCALE) 6"X12" TRAVERTINE COPING 3" FLUSH SPA TILED SPILLWAY SPA JET 2.5" 2" 10 ft. 2" SKIMMER TILED BENCH JEEP EDGE 3" COLOR L t) 3aP 1" V. 4 ft. LTH _ 41h" THICK WALLS SHALL NOT SLOPE GREATER THAN 11* 3' 4 ft. RS4 1 •• 1 ft. 6 WATER SUPPLY LINE \ R 1.5.. x VAC LINE v COLOR LED 1' COLOR LED TILED STEP EDGES 3.5' DEEP U 30" MIN. CLEARANCE U IN FRONT SALT OFSUBPANEL EQUIPMENT PAD FILTER PER FBC R4501.22 HEATER 2.5" 2.5" • APPROVED WITH THE 2017 FLORIDA BUILDING CODE FOR RESIDENTIAL 6W EDITION SPECIFICATIONS MAX. WIDTH 10' MAX. LENGTH 32' MIN. DEPTH 3.5' MAX. DEPTH 6' SHAPE CUST ELEVATION T.B.D FILL FROM EXCAVATION STOCKPILE TILE INTERIOR FINISH FILTER CS200 PUMP MAKE PER FBC 4501.20 GEM CATALINA PUMP HP: POOL FLOPRO VAR 2hp SPA 2HP PHPM FILTRATION PUMP COMPLIANT WITH ANSUAPSPIICC-15 2011 LIGHTS POOL 3 CLR LED SPA 1 CLR LED TRNFORM: POOL 100 WATT SPA 100 WATT MAIN DRAIN: POOL 2 SPA 1 SKIMMER (1) RETURNS: POOL 3 SPA 2 JETS: POOL 2 SPA 10 VALVED VAC LINE INCL FILL LINE NA DISCHARGE LINE TO GROUND CHLORINATOR TRU CLEAR SALT SYSTEM LADDER NA DIVING BOARD NA SLIDE NA HEATER AQUACALT115 _ VACUUM HEAD INCL POLE INCL VACUUM HOSE INCL BRUSH INCL LEAF SKIMMER INCL TEST KIT INCL TREE / STUMP REMOVAL NA SCREENED ENCLOSURE PIONEER AUTOMATION JANDY RS4 ELECTRICAL INCL POOL PATIO TRAVERTINE FRENCH PATTERN EXISTING PATIO NA DECK DRAIN NA GALLON CAPACITY -POOL 11,370 GAL. GALLON CAPACITY SPA- NA GAL. NA TURN -OVER RATE 6 hrS TERMITE TREAT INC BARRIER INCL MAX. WATER VELOCITY - 6 Ws FROM. TRUNK LINES TO 8 MIS SUCTION LINES. 10fps MAX RETURN LINE SKIMMER MIN FLOW 25 GPM SURFACE AREA OF POOL -_20 SQ. FT 80 LN FT JOB NAME: COFFFY ADDRESS: 453 SE-.._4RANJA AVE PSL PERMIT NO.: DATE DRAWN: MAY 7, 2019 DRAWN BY: DAVE CURLAND DESIGNER APPW AL: CUSTOMER APPROVAL: SCALE: 1/4" = 1' RAY REINHARD PE # 47041 1010 EASTER LILLY LANE rUNIT 203 VERO BEACH 329 A,Sc CONCRETE POOLS, INC W q py- p3�? a_3S7 REVIEWED FOR CODE COMPLIANCE ST. LUCIE COUNTY �OCC „ h 4� LE COPY SCANNED BY St. Lucie County