HomeMy WebLinkAboutPOOL INFORMATION18" 1 12" MIN. I • SEE TYPICAL WALL SECTION " • z FOR REINFORCEMENT NOTE: ALL STAIRS SHALL BE UNIFORM IN HEIGHT EXCEPT FOR THE TOP AND BOTTOM RISE WHICH MAY VARY FROM THE UNIFORM HEIGHT. STAIRS DETAIL 12" 12" MAX. 12" N.T.S. 6 9 T-6' 0' - 3' 3' ANGLE OF REPOSE = 1.5:1 . .s, 8" THICK WALL W/ #5 BARS @ 6" O.C.E.W. 6" THICK WALL W/#3 REBAR @ 6" O.C.E.W. OR 8" THICK WALL W/ #5 REBAR @ 12" O.C.E.W. 4" THICK WALL W/#3 REBAR @ 6" O.C.E.W: OR 5" THICK WALL W/ #3 REBAR @ 9" O.C.E.W. NOTE: SEE TYPICAL WALL SECTION WHEN WALL FALLS OUTSIDE OF THE ANGLE OF REPOSE ANGLE OF REPOSE N.T.S. WP MANUAL STARTER SWITCH (TYP.) /� - 3 -#12 WIRES IN 3/4" CONDUIT ❑ ► TO PUMP -� TO PUMP 2 (IF APPLICABLE) TO ELEC. SERVICE VIA WATER PROOF PANEL TO BLOWER (IF APPLICABLE) G.F.I. NO MORE THAN 20' FROM POOL 44 TO HEATER (IF APPLICABLE) EDGE AND NOT WITHIN 10' OF POOL EDGE 3 #8 WIRES IN 1"CONDUIT JUNCTION BOX 3 -#12 WIRES IN 3/4" CONDUIT 48" MIN. SPST TOGGLE SWITCH WATER LINE 12V TRANS. 18IMIN. 8 MIN. 1" NON -CORROSIVE CONDUIT 18 12V LIGHT W/>` POOL WALL AND DECK LOW WATER (SEE TYPICAL SECTION) CUTOFF DEVICE ELECTRICAL DIAGRAM N.T.S. GRATE TO BE ATTACHED HYDROSTATIC WITH SCREWS VALVE (1-1/2") a 3/4" ROCK BED (MIN 3YDS. .n ROCK TO STABILIZE SOIL) WELL POINT THREADED REMOVE GRATE AND WELL POINT VALVE PVC PIPE FROM MAIN DRAIN, AND ATTACH AUX. PUMP LINE WHEN EMPTYING WELLPOINT N.T.S. POOL LAYOUT NOTE: LAYOUT PROVIDED BY CONTRACTOR SCALE: 1/4" = V SWIMOUT DEPTH DETAIL NTS. 12'-2" w.w----- WATER LINE T-6 1 4'-11" 110 SLOPE J 11°SLOPE MAX. (TYP.) 1 MAX. (OPE.) 3 MAX. MAI=RAIN LOCATION LONGITUDINAL POOL SECTION N.T.S. 1:3 MAX. SLOPE I T FLAT 4" 4" THICK CONCRETE SLAB 6X6 - W1.41N1.4 WWM OR FIBERMESH DECK WIDTH VARIES •• 2- #3 BARS AT TOP 6" WATERLINE TILE TIED TO VERT. STEEL CI • ry J W < WIDTH VARIES FROM 4" - 6" W 12" ALONG BACK WALL = O a. m W J NOTES: 1.) WALLS UNDER FIN HEIGHT MAYBE 4" THICK W/ #3 1 BARS @12" O.C.E.W. CENTERED IN CONCRETE • g 2.) PAVERS MAY BE SUBSTITUTED FOR CONCRETE DECK. h HOWEVER, ANY FOOTER MUST BE DESIGNED BY OTHERS 3.) WALLS OVER 6' IN HEIGHT SHALL BE REINFORCED PER WALL OPTIONS TABLE BELOW • 4.) THIS DECK DESIGN IS NOT INTENDED TO BE R d ,al SUFFICIENT FOR SCREEN ENCLOSURE. ANY LOAD REQUIREMENTS FOR ADDITIONAL STRUCTURES SHALL BE DESIGNED BY OTHERS •, STEEL TEX. OR • EQUIVALENT PUMP WITH HAIR AND LINT STRAINER (SEE ATTACHED • • f •• - f ".i r • r a1 • i ♦ M k i• #3 BARS @ 12" O.C. E.W. J CENTERED IN CONCRETE TYPICAL WALL AND DECK SECTION (MAX. 6' HEIGHT) WASTE (RETAIN ON SITE) 4RELEASEVALV ILTER SYSTEM W/PRESSURE GAGE AND AIR EE LEGEND CHECKVALVE N 2-WAY VALVE -► FLOW DIRECTION NTS MAIN RETURN LINE PLASTER FINISH, GEM COAT OR EQUIVALENT • L 6" z Q~ Q 00 Q~ F O� O OW I- y Q W aIF 7 O �00 if '-U Q e LL POOL z w z J z Y J Um N 0 Q NOTE: PIPE SIZING TO BE DETERMINED BY HYDRAULIC CALCULATIONS PLUMBING DIAGRAM STAINLESS STEEL HANDRAIL (SAME BONDING FOR LADDER) MIN. #6 BARE AWG COPPER AROUND PERIMETER OF POOL 18"-24" CONNECT PERIMETER �\ GROUND WIRE TO - GROUND SYSTEM CONNECT#8 BARE AWG COPPER WITH APPROVED BOND CLAMP LIGHT NICHE -� NOTE: BONDING PER 250.8 AND 680.26(B) OF NFPA 70, NATIONAL ELECTRICAL CODE. N.T.S. 6" MAX. • • x� CONNECT #8 BARE AWG COPPER WITH APPROVED BOND CLAMP MIN. FOUR (4) CONNECTIONS (ONE EACH SIDE) W/ #8 BARE • AWG COPPER W/ APPROVED CLAMPS .a �s EQUIPOTENTIAL BONDING GRID DETAIL N.T.S. SAFETY NOTES 1. NO DIVING BOARD OR DIVING IS ALLOWED IN ANY POOL WITH A DEPTH LESS THAN 8'-8" AND SPECIFICALLY DESIGNED FOR DIVING. THIS POOL DOES NOT CONFORM TO THESE REQUIREMENTS AND NO DIVING SHALL BE PERMITTED 2. THIS POOL TO BE EQUIPPED WITH CHILD SAFETY FENCE AROUND THE PERIMETER OF THE POOL OR _X ALARMS AT THE ENTRANCES TO THE POOL (ONE TO BE CHECKED). GENERAL NOTES 1. ALL FLOORS AND WALLS OF POOL TO BE CONSTRUCTED USING PNEUMATICALLY APPLIED CONCRETE WITH 28 DAY STRENGTH OF 2500 PSI. 2. REINFORCING STEEL SHALL CONFORM TO A.S.T.M. 615 GRADE 60 3. PIPING TO BE SCHEDULE 40 PVC BEARING NSFAPPROVAL. 4. POOLS TO BE CONSTRUCTED ONLY ON CLEAN SAND OR ROCK. SOILS IN FINAL BACKFILL SHALL BE COMPACTED TO PROVIDE A MINIMUM BEARING CAPACITY OF 1000 ESE. ALL UNSUITABLE MATERIALS SHALL BE REMOVED AND REPLACED WITH CLEAN SAND PLACED AND COMPACTED IN 12" LIFTS. 5. ALL BACKFILL SHALL BE PLACED WITH CARE IN ORDER TO ENSURE THAT PLUMBING IS NOT DISTURBED. ALL FILL SHALL BE CLEAN SAND PLACED IN 12" LIFTS AND COMPACTED TO 98% OF MAXIMUM DENSITY. 6. THE CONTRACTOR SHALL TAKE ANY NECESSARY PRECAUTIONS IN ORDER TO PROTECT EXISTING STRUCTURES AFFECTED BY THE CONSTRUCTION. THE DESIGN ENGINEERACCEPTS NO RESPONSIBILITY FOR THE SAFETY OF EXISTING STRUCTURES. 7. ENGINEERING PLOT PLANS WERE NOT PREPARED FROM LEGAL SURVEYS OF THE EXISTING LOT AND RESIDENCE. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY ALL DIMENSIONS IN THE FIELD AND ESTABLISH LOT LINES WHEN NECESSARY. POOL CONTRACTOR AND/OR OWNER SHALL VERIFY LAYOUT SHOWN AND ALL DIMENSIONS PRIOR TO CONSTRUCTION. AS SUCH, THE ENGINEER ASSUMES NO RESPONSIBILITY FOR POOL CONSTRUCTION IN EASEMENTS OR REQUIRED SETBACKS. 8. CONTRACTOR SHALL LOCATE ALL EXISTING UTILITIES ON SITE AND SHALL MAINTAIN MINIMUM SEPARATIONS AS REQUIRED BY LOCAL REGULATIONS. GENERALLY, ELECTRICAL LINES SHALL BE A MINIMUM OF 10 FEET FROM OPEN WATER. 9. ALL UNSCREENED POOLS SHALL HAVE A FENCE A MINIMUM OF 4 FEET IN HEIGHT WITH SELF-LOCKING GATES. 10. WHERE POOLS ABUT OR ARE PLACED NEAR SEAWALLS OR BULKHEADS SPECIAL CARE SHOULD BETAKEN. NOTIFY ENGINEER OF THIS CONDITION FOR ANALYSIS AND RE -DESIGN IF NECESSARY. 11, PATIO DESIGN MAY BE NOTED TO BE COMPLETED BY OTHERS. WHEN NOTED, ANY DETAILS REFERRING TO PATIO DESIGN ARE NOT APPLICABLE. THE TYPICAL WALL SECTIONS OF POOL ARE NOT APPLICABLE TO PAVEMENT DESIGN. 12. VACUUM LINE SHALL INCLUDE A SPRING LOADED SELF CLOSING COVER. 13. THE SWIMMING POOL HAS BEEN DESIGNED TO BE COMPLIANT WITH THE 2017 FLORIDA BUILDING CODE 6TH EDITION, AS WELL AS THE 2014 NATIONAL ELECTRIC CODE, ANSI/APSP-7, AND SHALL BE ANSI 15 COMPLIANT. 14. BASE MATERIAL THICKNESS MUST BE 125% OF CONCRETE FASTENER EMBEDMENT. 15. HOMEOWNER MUST BE AWARE OF THE POSSIBILITY OF EROSION AND SHALL BE RESPONSIBLE FOR MAINTENANCE IN ORDER TO PREVENT FAILURE. 16. WATER VELOCITY MAXIMUM 8 FT/SEC AS PER FBC 2017-R4601.6.3 17. POOL BARRIER TO COMPLY WITH FBC 2017-R4501.17 18. SKIMMERS TO COMPLY WTH FBC 2017-4501,21.2 19. EQUIPMENT FOUNDATION CONCRETE SLAB, MIN, 3.5" THICK, POUR IN PLACE. 20. WATER HEATING EQUIPMENT TO COMPLY WITH FBC 2017-114501 21. ALL DECK AND SLAB CONCRETE SHALL HAVE A COMPRESSIVE STRENGTH OF 3000 P.S.I. IN 28 DAYS UNLESS OTHERWISE NOTED. 2014 NEC POOL PUMP ENERGY EFFICIENCY REQUIREMENTS :QUIREMENTS APPLY TO EXISTING POOL DOESNT APPLY TO REPLACEMENTS/ADDITIONS AND NEW COMMERCIAL POOLS CONSTRUCTION [IS THE PUMP MOTOR USED TO FILTER WATER? I CANNOT BE SPLIT -PHASE, SHADED DOESN'T APPLY TO POLE OR CAPACITOR CIRCULATION WITHOUT START -INDUCTION TYPES FILTRATION IS THE TOTAL HORESPOWER ONE OR LARGER? TOTAL HE = PUMP HP x SERVICE FACTOR ALSO FOLLOW THESE REQUIREMENTS: SINGLE SPEED PUMP - PUMP AND PUMP MOTORS MUST BE TWO OR MORE SPEEDS. PERMITTED. ADDITIONAL - CONTROLS NED TO BE CAPABLE OF OPERATING AT A REQUIREMENTS MAY APPLY MINIMUM OFTWO SPEEDS. CONTINUE ON. - DEFAULT CIRCULATION MUST BE THE RESIDENTIAL FILTRATION SPEED. THE HIGHER SPEED OVERRIDE IS NOT TO EXCEED ONE NORMAL CYCLE OR 24 HOURS, WHICHEVER IS LESS. - SOLAR POOL HEATING SYSTEMS ARE PERMITTED TO RUN AT HIGHER SPEEDS DURING PERIODS OF USABLE HEAT GAIN. IS THIS NEW CONSTRUCTION? ADDITIONAL REQUIREMENTS PER APSP-15:. NO ADDITIONAL - SIZE THE PUMP BASED ON: REQUIREMENTS ARE IN -- POOL GALLONS / 360 MIN. AND SELECTING PUMP FROM PLACE DATABASE WITH CURVE A OR C LISTED FLOWRATE EQUAL TO OR LESS THAN CIRCULATED FILTRATION FLOWRATE. - A TIME SWITCH MUST BE INSTALLED TO ALLOW POOL OWNERS TO RUN THE POOL FILTRATION. PUMP ONLY DURING THE OFF-PEAK PERIOD AND FOR THE MINIMUM TIME NECESSARY TO MAINTAIN THE WATER IN THE CONDITION REQUIRED BY APPLICABLE PUBLIC HEALTH STANDARDS. - FILTERS MUST HAVE A MINIMUM AREA BASED ON THE 6 HOUR TURNOVER FLOW RATE. -- POOL GAL. / 360 MIN. = FLOWRATE (IN GPM) -- DIVIDE GPM BY A NUMBER SHOWN TO FIND THE FILTER'S MIN, SQUARE FOOTAGE. (CARTRIDGE = .375, SAND = 15, DE = 2) - MIN. DIAMETER OF BACKWASH VALVES MUST BE TWO INCHES OR THE DIAMETER OF THE RETURN PIPE WHICHEVER IS GREATER. ){ ®�) pq /� FOR - SWEEP ELBOWS ARE RECOMMENDED. REVF' 91MED -(REMEMBER: RESIZE PIPING SO VELOCITY AT MAX FLOW IANCE. DOES NOT EXCEED 8 FPS IN THE SUCTION LINE AND 6 FPS IN ��� ^OMP!W+S �M THE SUCTION LINE, AND ALSO MEETS VGB/ANSI-7 ENTRAPMENT AVOIDANCE REQUIREMENTS.) �•(� ST• LUCIE CO BOCC PLUG PORTS NOT BEING USE6 TONAL SINGLE CONNECTION ORYIYOROSTA. VALVE INTERIOR AMEt MUO NG POOL FINISH I, 0 a 0 p ° a c° p. ° ♦ °. ,.'LZ.' Oo a 9 O O. p pp 4 a: tl ..v :YJ: ° • a o °p. o. a ''o a4 00:o a o a a o00 od o0 00 ° •. ° IY1_[;I :It1I:l. O a o 0 0 0 °o o e aoo o °.Poo o °oo e a p o 00 o O a 17:�C1.13. � o o• o p o o po o °a. o° Q oo" o ao o p• o o. o• L1.:�f'T 3_I TJ LJ .. o o G o° o a a o v o o c e o° oo p. a s L713.iyt: :13 ax171� 000 000 0Q)9 LLLIw EA RT::///"0 OTCRETE I GUNITE 'RAW TO PIOM USTOM MOLDED PRODUCTS 2" CHANNEL DRAIN SINGLE PIPE CONNECTION ON ANY OF THREE PORTS. GB-2009 COMPLIANT 1-1rr:x.ZI**,3"ORGREArERPIPE ODEL: CMP 25506-32X NOTE: THE MAXIMUM FLOW RATING FOR THIS SUCTION FITTING AS CONFIGURED WITH OUTER PORTS PLUGGED AND CENTER PORT OPEN IS 200 GPM (FLOOR) WHEN USING 2.5" PLUMBING AND 184 GPM WHEN USING 2" PLUMBING. CHANNEL DRAIN INSTALLATION DETAIL APR 9.. 5 119 ST. Lucie County, P<drmittln9 QI REMOVED HEAT PUNI�R}7Q�P�C y aMQUT, CJR, 4/17/19 e•G�,�,• C E N stc••�(b�'C No,70170 •e TATE OF t� / G % '-< .Y CLINTON RAHJE , ,o� DNAL -N- DATE FL. LICENSE No, 70170 L.B./C.O.A. No. 29080 FILE COPY PIPELINE POOLS AND PAVERS, INC. SASSEVILLE RESIDENTIAL POOL 25 MAJESTIC WAY SCANNE FORT PIERCE, FL 34949 BY St. Lucie Co POOL LAYOUT AND DETAILS 40 ENGINEERING DESIGN, LLC. 4731 N. Hwy Al A, Ste. 228 Phone: (772) 226-0224 Vero Beach, FL 32963 E-Mail: rpengdesignllc@gmail.com DATE: 1 1 9 SHEET 1 O F 1 PROJ. NO.:O.:9-33