HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2014
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CalAtlanlic RB Yorkshire Lot 36
Builder Name: CalAtlantic Homes
SCANNED
Street: 13316 NW Baywood PI
Permit Office:
BY
City, State, Zip: Port St. Lucie , FL,
Permit Number:
Owner: CalAtlantic Homes
Jurisdiction:
c+r+
Staa . Luab-Claunty
Design Location: FL, ST_LUCIE_CO_INTL
1. New construction or existing New (From Plans)
9. Wall Types (3646.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Inl Insul, Exterior
R=4.1 3321.00 ft2
b. Frame - Wood, Adjacent
R=11.0 325.43 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3688.0 sqft.)
Insulation Area
a. CathedrallSingle Assembly (Unvented) R=20.0 3688.00 ft2
6. Conditioned Floor area above grade (ft2) 3688
b. N/A
R= ft2
Conditioned floor area below grade (ft2) 0
c. N/A
R= ft2
11. Ducts
R ft2
7. Windows(583.5 sqft.), Description Area
a. Sup: AC 1 Main, Ret: AC 1 Main, AH:
AC 1 Main 6 360
a. U-Factor. Sgl, U=1.07 257.35 ft
b. Sup: AC 2 Master, Rat: AC 2 Master, AH: AC 1 M 6 220
SHGC: SHGC=0.30
b. U-Factor. Sgl, U=0.77 248.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
54.5 SEER:14.00
b. Central Unit
17.8 SEER:14.00
c. U-Factor: Sgl, U=1.00 78.17 ft2
'
SHGC: SHGC=0.32
13. Heating systems
kBlu/hr Efficiency
d. U-Factor: WA ft2
a. Electric Heat Pump
55.5 HSPF:8.20
SHGC:
b. Electric Heat Pump
17.6 HSPF:8.20
Area Weighted Average Overhang Depth: 7.076 ft.
Area Weighted Average SHGC: 0.269
14. Hot water systems
8. Floor Types (3688.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3688.00 ft2
b. Conservation features
EF: 3.100
b. WA R= ft2
None
c. NIA R= ft2
15. Credits
Pslal
Glass/Floor Area: 0.158 Total Proposed Modified Loads: 90.41
PASS
Total Baseline Loads: 99.65
1 hereby certify that the plans and specifications covered by
Review of the plans and
OF Liifi sTq
this calculation are in compliance with the ..jorida Energy
Code.
specifications covered by this
y ,�Oaf,
=?r
Dlgilallysigned byChdsWildroutlt
calculation indicates compliance
h r,„'n 4%
DN:m=Chds wildroudt, c=US,
Chris
with the Florida Energy Code.
=sgfi'.',a`aa
!. nrn ". t O
n=Engineered Air, LLC, ou=Sates
PREPARED BY: end Enoneedng
Before construction is completed
O
DATE: Mdr email-Ghdsw@engineersdaidic.
this building will be inspected for
compliance with Section553.908
W y
oate:zms.to.tai3:ca:33-04-00•
I hereby certify that this building, as/�igned, is in compliance
Florida Statutes.
R
with the Florida Energy Code.
- �'Op we
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
I'b ry'!'46 :iInli
- Compliance requires certification by the air handler unit manufacturer that the
certified factorysealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accol
test report in accordance with R402.4.1.2.
10/18/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software
FORM R405-2014
PROJECT
Title:
CalAtlanlic RB Yorkshire Lot 3 Bedrooms: 4
Address Type:
Street Address
Building Type:
User
Conditioned Area: 3688
Lot #
36
Owner:
CalAtlantic Homes
Total Stories: 1
Block/SubDivision:
Riverbend
# of Units:
1
Worst Case: No
PlalBook:
Builder Name:
CalAtlantic Homes
Rotate Angle: 0
Street:
13316 NW Baywood PI
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie,
Family Type:
Single-family
FL, —
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
58
Medium
BLOCKS
Number
Name
Area Volume
1
Blockl
2766 29960.3
2
Block2
922 9837.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
AC 1 Main
2766 29960.3 No 5
3
1 Yes
Yes
Yes
2
AC 2 Master
922 9837.7 No 2
1
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio AC 1 Main 248 ft 0
2766 ft2
__
0 0
1
2 Slab -On -Grade Edge Insulatio AC 2 Master 91 ft 0
922 ft2
_-
0 0
1
ROOF
Roof Gable Roof
Solar
SA Emitt
Emitt Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Barrel tile 3995 ft2 0 ft2 Light
0.5
No 0.5
No 20
22.6
ATTIC
#
EV
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
No attic
Unvented 0 3688 ft2
N N
10/18/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2014
CEILING
#
Ceiling Type Space
R-Value
Area
Framing Frac
Truss Type
1
Cathedral/Single Assembly (UnvenleBC 1 Main
20
2766 ft'
0.11
Wood
2
Cathedral/Single Assembly (UnventAd 2 Master
20
922 ft'
0.11
Wood
WALLS
Adjacent Space
Cavity
Width Height
Sheathing Framing
Solar
Below
_ 1
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
13
0 10.67 0
138.7 ft'
0.3
0
0.3
0
_ 2
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
10
0 10.67 0
106.7 ft'
0.3
0
0.3
0
_ 3
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
13
0 10.67 0
138.7 ft'
0.3
0
0.3
0
-4
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
12
0 10.67 0
128.0 ft'
0.3
0
0.3
0
_ 5
S
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
80
0 10.67 0
853.6 R'
0.3
0
0.3
0
_ 6
S
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
13.5
0 10.67 0
144.0 ft'
0.3
0
0.3
0
_ 7
W
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
34
0 10.67 0
362.8 ft'
0.3
0
0.3
0
_ 8
E
Exterior
Concrete Black - Int InsulAC 1 Main
4.1
20
0 12.67 0
253.4 ft'
0.3
0
0.3
0
_ 9
N
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
14
0 10.67 0
149.4 ft'
0.3
0
0.3
0
_ 10
N
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
24
0 10.67 0
256.1 ft'
0.3
0
0.3
0
_ 11
N
Garage
Frame -Wood AC 1 Main
11
8
0 10.67 0
85.4 ft'
0.3
0.3
0
12
W
Garage
Frame - Wood AC Main
11
6
010.67 0
64.0 ft'
0.3
0.3
0
_ 13
W
Exterior
Concrete Block - Int InsukC 2 Master
4.1
18
0 10.67 0
192.1112
0.3
0
0.3
0
_ 14
N
Exterior
Concrete Block - Int InsuAC 2 Master
4.1
50
0 10.67 0
533.5 R'
0.3
0
0.3
0
_ 15
S
Exterior
Concrete Block - Int InsuAC 2 Master
4.1
6
0 10.67 0
64.0 ft'
0.3
0
0.3
0
16
E
Garage
Frame - Wood AC 2 Master
11
16.5
0 10.67 0
176.1 ft2
0.3
0.23
0.3
0
DOORS
#
Omt
Door Type Space
Stones U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated AC 1 Main
None .2
2.7
8
21.4 ft'
WINDOWS
Orientation shown is the entered, Proposed orientation.
Wall
' Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor
SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Single Yes
1.07
0.3
32.5 ft'
1 ft 4 in
2 ft 0 in
None
None
2
E 1
Metal Low-E Single Yes
1
0.32
21.3 ft'
1 ft 4 in
2 ft 0 in
None
None
_
3
E 2
Metal Low-E Single Yes
1.07
0.3
32.5 ft'
1 it 4 in
2 ft 0 in
None
None
4
E 3
Metal Low-E Single Yes
1.07
0.3
16.2 ft'
1 ft 4 in
2 ft 0 in
None
None
_
5
E 4
Metal Low-E Single Yes
0.77
0.22
40.0 fN
11 ft 0 in
3 ft 0 in
None
None
6
S 5
Metal Low-E Single Yes
1.07
0.3
22.7 ft'
1 ft 4 in
2 ft 0 in
None
None
7
S 5
Metal Low-E Single Yes
1.07
0.3
9.2 ft'
1 ft 4 in
2 ft 0 in
None
None
8
S 6
Metal Low-E Single Yes
0.77
0.22
40.0 ft'
18 ft 0 in
3 it 0 in
None
None
_
9
W 7
Metal Low-E Single Yes
1.07
0.3
117.0 ft'
1 ft4In
2 ft 0 in
None
None
10
E 8
Metal Low-E Single Yes
0.77
0.22
128.0 ft 12
ft 0 in
3 it 0 in
None
None
11
E 8
Metal Low-E Single Yes
1
0.32
24.9 ft'
12 ft 0 in
1 ft 0 in
None
None
_
12
N 14
Metal Low-E Single Yes
1.07
0.3
13.7 ft'
1 ft 4 in
2 it 0 in
None
None
13
N 14
Metal Low-E Single Yes
1
0.32
9.2 ft'
1 ft 4 in
2 ft 0 in
None
None
10/18/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
14
15
16
17
N 14 Metal Low-E Single Yes
N 14 Metal Low-E Single Yes
S 15 Metal Low-E Single Yes
N 9 Metal Low-E Single Yes
1 0.32 16.2 ft' 1 ft 4 in 2 110 in None
1 0.32 6.7 ft' 1 ft 4 in 2 it 0 in None
1.07 0.3 13.7 ft' 1 114 in 2 ft 0 in None
0.77 0.22 40.0 ft' 18 ft 0 in 3 It 0 in Drapes/blinds
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
640 ft' 640 ft'
78 ft loft ' 1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000343
3316.5 182.07 342A1 .2571 5
HEATING SYSTEM
#
System Type Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump Split
Electric Heat Pump Split
HSPF:8.2 55.5 kBtu/hr 1
HSPF:8.2 17.6 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit Split
Central Unit Split
SEER: 14 54.5 kBtuQu 1900 cfm 0.75 1
SEER: 14 17.8 kBlu/hr 600 ctm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use SelPnt Conservation
1
Electric Heat Pump Garage
3.1 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft'
DUCTS
V #
Supply — — Return -- Air CFM 25 CFM25
Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF
HVAC #
Heat Cool
1
2
AC 1 Main 6 360 ft' AC 1 Main 80 ft' Default Leakage AC 1 Main (Default) (Default)
AC 2 Master 6 220 ft- AC 2 Master 120 ft' Default Leakage AC 1 Main (Default) (Default)
1 1
2 2
10/18/2016 1:02 PM EnergyGauge® USA - FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
Programabl[e
Y
Ceiling Fans:
HeatiOct
ng [X]
an
Jan
Feb
Mar
Apr
(1X
rr Jul�(
I I
i
i
rl
ff
Nov
Dec
Venting [[
JJ1 Jan [[[
!
111 Feb
1
X Mar
May
[ Jun
Jul
[ Aug
Sep [XI
Oct
X Nov
Dec
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating(WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Heating (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
10/18/2016 1:02 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
ENERGY PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX" = 91
The lower the EnergyPerformance Index, the more efficient the home.
13316 NW Baywood PI, Port St. Lucie, FL,
1. New construction or existing
2. Single family or multiple family
3. Number of units, if multiple family
4. Number of Bedrooms
5. Is this a worst case?
6. Conditioned floor area (ft�
7. Windows"
a. U-Factor:
SHGC:
b. U-Factor:
SHGC:
c. U-Factor:
SHGC:
d. U-Factor:
SHGC:
Description
Sgl, U=1.07
SHGC=0.30
Sgl, U=0.77
SHGC=0.22
Sgl, U=1.00
SHGC=0.32
N/A
Area Weighted Average Overhang Depth:
Area Weighted Average SHGC:
8. Floor Types
a. Slab -On -Grade Edge Insulation
b. N/A
c. N/A
New (From Plans)
9. Wall Types Insulation
Single-family
a. Concrete Block - Int Insul, Exterior R=4.1
b. Frame - Wood, Adjacent R=11.0
1
c. NIA R=
4
d. N/A R=
10. Ceiling Types Insulation
No
a. Cathedral/Single Assembly (Unvented) R=20.0
3688
b. N/A R=
Area
c. N/A R=
257.35 ft'
11. Ducts
a. Sup: AC 1 Main, Ret: AC 1 Main, AH: AC 1 Main
b. Sup: AC 2 Master, Ret: AC 2 Master, AH: AC 1 M
248.00 ft'
78.17 ft
ft'
7.076 ft.
0.269
Insulation
Area
R=0.0
3688.00 ft'
R=
ft'
R=
fe
12. Cooling systems
a. Central Unit
b. Central Unit
13. Heating systems
a. Electric Heat Pump
b. Electric Heat Pump
14. Hot water systems
a. Electric
b. Conservation features
None
15. Credits
I certify that this home has complied with the Florida Energy Efficiency Code for Building
Construction through the above energy saving features which will be installed (or exceeded)
in this home before final inspection. Otherwise, a new EPL Display Card will be completed
based on installed Code compliant features.
Builder Signature: Date: ippo/%/rL
Address of New Home:� j1UNW (�� ws�r� PL_ City/FL Zip:li2�_ 5 )r („ 4,c--C,
Area
3321.00 ft'
325.43 ft'
ft'
ft'
Area
3688.00 ft'
ft'
ft'
R ft'
6 360
6 220
kStufhr Efficiency
54.5 SEER:14.00
17.8 SEER:14.00
kBtu/hr Efficiency
55.5 HSPF:8.20
17.6 HSPF:8.20
Cap: 50 gallons
EF: 3.1
Pstat
'Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
"Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
10118120161:03 PM EnergyGauge® USA- FlaRes2014 -Section R405.4.1 Compliant Software Page 1 of 1
Yorkshire Model
HVAC Load Calculations
for
Standard Pacific Homes
rEVAC HVAC LOADS
Prepared By:
Chris Wildroudt
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, ar
Rhvac-Residential B Light Commercial HVAG toads Elite Software Development, Inc.
Engineered Air, LLC Yorkshire Model.
®
Margate, FL 33063 Page 2
Project Report
General Project Information
Project Title: Yorkshire Model
Designed By: Chris Wildroudt
Project Date: 12-4-13
Client Name: Standard Pacific Homes
Company Name: Engineered Air LLC CAC045860
Company Representative: Chris Wildroudt
Company Address: 2520 N Andrews Ave Ext
Company City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
Desi-n3Data:
Reference City: West Palm Beach, Florida
Building Orientation: House faces East
Daily Temperature Range: Medium
Latitude: 26 Degrees
Elevation: 15 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 45 42.23 n/a n/a 70 n/a
Summer: 91 78 56% 50% 75 59
Total Building Supply CFM: 2,343 CFM Per Square ft.: 0.635
Square ft. of Room Area: 3,688 Square ft. Per Ton: 665
Volume (ft3) of Cond. Space: 39,351
iBuildin .Loads
Total Heating Required Including Ventilation Air: 43,384 Btuh 43.384 MBH
Total Sensible Gain: 51,529 Btuh 77 %
Total Latent Gain: 15,063 Btuh 23 %
Total Cooling Required Including Ventilation Air: 66,592 Btuh 5.55 Tons (Based On Sensible + Latent)
INdtes Im
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
SANEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
Rhbac - Residential B Light Commercial HVAC Loads
-
-
- - Elite Software Development, Inc.
Engineered Air, LLC
®
Yorkshire_ Model
Mar ate; FL 33063
Page 3
Total Building Summary Loads
Component r M q 3 s ;ad
Area
Sen
; Later, ,, «SensyTotal;
DescriQuan
Loss==Gain
Gamma
Galrt
Lo-E French Door: Glazing-Low-E French Door, u-value
96
1,848
0
1,628
1,628
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
460
0
600
600
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,335
0
5,404
5,404
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
770
0
956
956
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
282.8
4,238
0
5,931
5,931
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
229
0
296
296
0.4, SHGC 0.31
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
2389.4
8,543
0
5,569
5,569
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
1566
1,253
0
1,553
1,553
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
339
8,382
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
32,809
0
28,148
28,148
People:
7
2,100
1,960
4,060
Equipment:
4,700
5,100
9,800
Lighting:
1400
4,774
4,774
Ductwork:
3,905
3,230
4,638
7,868
Infiltration: Winter CFM: 243, Summer CFM: 125
6,670
5,033
2,191
7,224
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
.0
4,718
4,718
Total Building Load Totals:
43,384
15,063
51,529
66,592
[ChecklFi ures
Total Building Supply CFM: 2,343
CFM Per Square ft.:
0.635
Square ft. of Room Area: 3,688
Square ft. Per Ton:
665
Volume (ft3) of Cond. Space: 39,351
IBuildio Wrroads
Total Heating Required Including Ventilation Air:
43.384 Btuh
43.384
MBH
Total Sensible Gain:
51,529 Btuh
77
%
Total Latent Gain:
15,063 Btuh
23
%
Total Cooling Required Including Ventilation Air:
66,592 Btuh
5.55
Tons (Based
On Sensible +
Latent)
INotes
Rhvac is an ACCA approved Manual J and Manual D computer
program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and
ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's
performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
Rlivac - Residential & Light Commercial HVAC Loads
Engineered Air, LLC
E
Elite Software Development, Inc.
Yorkshire Model
Margate, FL 33063
Pa e4
System 1 AC 1 - First Floor Summary
Loads
Descnahon r ?} ''� Quan Loss Gain
Gain,
Total'
9 Gain:
Lo-E French Door: Glazing-Low-E French Door,u-value
96
1,848
0
1,628
1,628
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
460
0
600
600
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,335
0
5,404
5,404
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
770
0
956
956
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
148.8
2,230
0
2,404
2,404
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
0.59, SHGC 0.32
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
1756.6
6,280
0
4,095
4,095
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
128
131
0
131
131
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
697
558
0
691
691
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pi: Floor -Slab on grade, No edge insulation, no
248
6,132
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
25,184
0
21,809
21,809
People:
5
1,500
1,400
2,900
Equipment:
4,000
3,500
7,500
Lighting:
1000
3,410
3,410
Ductwork:
2,995
924
3,536
4,460
Infiltration: Winter CFM: 185, Summer CFM: 95
5,098
3,847
1,675
5,522
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
3,954
3,954
System 1 AC 1 - First Floor Load Totals:
33,277
10,271
39,283
49,555
Check Fi ures
Supply CFM: 1,787
CFM Per Square ft.:
0.634
Square ft. of Room Area: 2,819
Square ft. Per Ton:
683
Volume (fN) of Cond. Space: 30,079
S stem Loads
Total Heating Required Including Ventilation Air:
33,277 Btuh
33.277
MBH
Total Sensible Gain:
39,283 Btuh
79
%
Total Latent Gain:
10,271 Btuh
21
%
Total Cooling Required Including Ventilation Air:
49,555 Btuh
4.13
Tons (Based On Sensible + Latent)
(Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's
performance data
at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rhg Wednesday, December 04, 2013, 2:36 PM
Rhvac - Residential & Light Commercial HVAC Loads
Elite Software Development, Inc.
Engineered Air, LLC
®
Yorkshire Model
Margate, FL 33063
Pa e 5
System 2 AC 2 - Second Floor Summary Loads
Com bnenf 'NA' , rn•, ' :xl
orhp x,n
< ;u
t Area s y Seens t-t Lat" Sen , ,*Total.
Descn tion ..{.-:.r
_1 QuanN .Loss
?t"�Gain
�Gairi Gain
Lo-E operable: Glazing-Low-E Operable Glass, u-value
134 2,008
0
3,527 3,527
0.6, SHGC 0.31
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8 229
0
296 296
0.4, SHGC 0.31
13A-4ocs: Wall -Block, board insulation only, R-4 board
632.7 2,263
0
1,474 1,474
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
176.1 180
0
180 180
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
869 695
0
862 862
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
91 2,250
0
0 0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
7,625
0
_
6,339 6,339
People:
2
600
560 1,160
Equipment:
700
1,600 2,300
Lighting:
400
1,364 1,364
Ductwork:
910
2,306
1,102 3,408
Infiltration: Winter CFM: 57, Summer CFM: 29
1,572
1,186
516 1,702
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0 0
AED Excursion:
0
0
764 7_64_
System 2 AC 2 - Second Floor Load Totals:
10,107
_
4,792
12,245 17,037
,Check] uses
Supply CFM: 557
CFM Per Square ft.:
0.641
Square ft. of Room Area: 869
Square ft. Per Ton:
- 612
Volume (W) of Cond. Space:, 9,272
Sytstem Loads
Total Heating Required Including Ventilation Air:
10,107 Btuh 10.107
MBH
Total Sensible Gain:
12,245 Btuh 72
%
Total Latent Gain:
4,792 Btuh 28
%
Total Cooling Required Including Ventilation Air:
17,037 Stuh 1.42
Tons (Based On
Sensible + Latent)
Ndtes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition,
Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's
performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
r FORM R405-2014
Ef FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business and Professional Regulation - Residential Performance Method
Project Name: CalAtlantic RB Yorkshire Lot 36
Builder Name: CalAtlantic Homes
Street: t'5316 NW &,,(tatoA AAC.0
Permit Office:
SCANNED
City, State, Zip: Port St. Lucie , FL ,
Permit Number:
BY
Owner: CalAtlantic Homes
Jurisdiction:
St. Lucie County
Design Location: FL, ST_LUCIE_CO]NTL
1. New construction or existing New (From Plans)
9. Wall Types (3646.5 sqft.)
Insulation Area
2. Single family or multiple family Single-family
a. Concrete Block - Int Insul, Exterior
R=4.1 3321.00 1112
-
b. Frame - Wood, Adjacent
R=11.0 325.43 ft2
3. Number of units, if multiple family 1
c. N/A
R= ft2
4. Number of Bedrooms 4
d. N/A
R= ft2
5. Is this a worst case? No
10. Ceiling Types (3688.0 sgft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 3688.00 ft2
6. Conditioned floor area above grade (ft2) 3688
b. NIA
R= ft2
Conditioned floor area below grade (ft2) 0
c. NIA
R= ft2
11. Ducts
R ft2
7. Windows(583.5 sqft.) Description Area
a. Sup: Attic, Ret: Attic, AH: AC 1 Main
6 360
a. U-Factor: Sgl, U=1.07 257.35 ft2
b. Sup: Attic, Rat: Attic, AH: AC 1 Main
6 220
SHGC: SHGC=0.30
b. U-Factor: Sgl, U=0.77 248.00 ft2
12. Cooling systems
kBtu/hr Efficiency
SHGC: SHGC=0.22
a. Central Unit
54.5 SEER:14.00
c. U-Factor: Sgl, U=1.00 78.17 ft2
b. Central Unit
17.8 SEER:14.00
SHGC: SHGC=0.32
13. Heating systems
kBtu/hr Efficiency
d. U-Factor: NIA ft2
a. Electric Heat Pump
55.5 HSPF:8.20
SHGC:
b. Electric Heat Pump
17.6 HSPF:8.20
Area Weighted Average Overhang Depth: 7.076 it.
Area Weighted Average SHGC: 0.269
14. Hot water systems
8. Floor Types (3688.0 sqft.) Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3688.00 ft2
b. Conservation features
EF: 0.940
J. N/A R= ft2
None
G. WA R= ft2
15. Credits
Pstat
Glass/Floor Area: 0.158 Total Proposed Modified Loads: 97.80
PASS
Total Baseline Loads: 99.79
I hereby certify that the plans and specifications covered by
Review of the plans and
THE ST9TF
this calculation are in compliance with the Florida Energy
specifications covered by this
OF
y � O
DigitallysigmdbyChdswndmmc
Code. �..d
wldn,udl, Fus, Chris
calculation indicates complianceDN:m=Chas
with the Florida Energy Code.
FPREPARED
Air, LLC,
o=Engineered ou=Sales
BY: r gT-M-
Before construction is completed
DATE:_ ��-c�hdse^9i^aereeai^i°.
this building will be inspected for
compliance with Section 553.908
PO.�i
r e
Date: 201e:02.0412:24:0e-0600,
designed,
I hereby certify that this building, as is in compliance
Florida Statutes.
9�
with the Florida Energy Code.
Op WS Sid
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
certified factorysealed in accordance with R403.2.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and an envelope leakage
test report in accordance with R402,4.1.2.
ol COPY
214/2016 12:21 PM EnergyGaugeO USA- FlaRes2014 Section R405.4.1 Compliant Software Page 1 of 5
FORM R405-2014
r
PROJECT
Title:
CalAdantic RB Yorkshire Lot Bedrooms: 4
Address Type:
Lot Information
Building Type:
User
Conditioned Area: 3688
Lot #
36
Owner:
CalAtlantic Homes
Total Stories: 1
Block/SubDivision:
Riverbend
# of Units:
1
Worst Case: No
PlatBook:
Builder Name:
CalAtlantic Homes
Rotate Angle: 0
Street:
Permit Office:
Cross Ventilation:
County:
St. Lucie
Jurisdiction:
Whole House Fan:
City, State, Zip:
Port St. Lucie ,
Family Type:
Single-family
FL,
New/Existing:
New (From Plans)
Comment:
CLIMATE
/
IECC Design Temp
Int Design Temp Heating
Design Daily Temp
V Design Location
TMY Site Zone 97.5 % 2.5 %
Winter
Summer Degree Days Moisture
Range
FL, ST_LUCIE_CO_INTL FL_ST_LUCIE_CO_INTL 2 39 90
70
75 722
58
Medium
BLOCKS
Number
Name
Area Volume
1
Block1
2766 29960.3
2
Block2
922 9837.7
SPACES
Number
Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1
AC 1 Main
2766 29960.3 No 5
3
1 Yes
Yes
Yes
2
AC 2 Master
922 9837.7 No 2
1
1 Yes
Yes
Yes
FLOORS
#
Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio AC 1 Main 248 ft 0
2766 ft2
___
0 0
1
2SIab-On-Grade Edge Insulatio AC 2 Master 91 ft 0
922 ft2
___
0 0
1
ROOF
/
Roof Gable Roof
Solar
SA Emift
Emitl Deck
Pitch
V #
Type
Materials Area Area Color
Absor.
Tested
Tested Insul.
(deg)
1
Hip
Barrel tile 3995 ft2 0 ft2 Light
0.5
No 0.5
No 38
22.6
ATTIC
/
v #
Type
Ventilation Vent Ratio (1 in)
Area
RBS IRCC
1
Full attic
Vented 150 3688 ft2
N N
2/4/2016 12:21 PM EnergyGaugeO USA- FlaRes2014 Section R405.4.1 Compliant Software Page 2 of 5
FORM R405-2014
r
CEILING
#
Ceiling Type Space
R-Value
Area
Framing Free
Truss Type
1
Under Attic (Vented) AC 1 Main
38
2766 ft2
0.11
Wood
2
Under Attic (Vented) AC 2 Master
38
922 ft2
0.11
Wood
WALLS
Adjacent
SpaceR-VAI-te-
Cavity
Width Height
Sheathing Framing
-
Solar
Below
- nr o -
_ 1
E
Exterior
Concrete Block- Int InsulAC 1 Main
4.1
13
0 10.67 0
138.7 ft2
0.3
0
0.3
0
2
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
10
0 10.67 0
106.7 ft-
0.3
0
0.3
0
-3
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
13
0 10.67 0
138.7 ft2
0.3
0
0.3
0
4
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
12
0 10.67 0
128.0 ft2
0.3
0
0.3
0
_ 5
S
Exterior
Concrete Block- Int InsulAC '1 Main
4.1
80
0 10.67 0
853.6 IF
0.3
0
0.3
0
-6
S
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
13.5
0 10.67 0
144.0 ft2
0.3
0
0.3
0
-7
W
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
34
0 10.67 0
362.8 ft2
0.3
0
0.3
0
_ 8
E
Exterior
Concrete Block - Int InsulAC 1 Main
4.1
20
0 12.67 0
253.4 ft2
0.3
0
0.3
0
_ 9
N
Exterior
Concrete Block -Int InsulAC 1 Main
4.1
14
0 10.67 0
149.4 ft2
0.3
0
0.3
0
_ 10
N
Exterior
Concrete Block - Int Insu14C 1 Main
4.1
24
0 10.67 0
256.1 ft2
0.3
0
0.3
0
_ 11
N
Garage
Frame - Wood AC 1 Main
11
8
0 10.67 0
85.4 ft2
0.3
0.3
0
_ 12
W
Garage
Frame - Wood AC 1 Main
11
6
0 10.67 0
64.0 ft2
0.3
0.3
0
_ 13
W
Exterior
Concrete Block- Int InstAC 2 Master
4.1
18
0 10.67 0
192.1 ft2
0.3
0
0.3
0
_ 14
N
Exterior
Concrete Block - Int InsiA.0 2 Master
4.1
50
0 10.67 0
533.5 ft2
0.3
0
0.3
0
_ 15
S
Exterior
Concrete Block - Int Insu&C 2 Master
4.1
6
0 10.67 0
64.0 ft2
0.3
0
0.3
0
16
E
Garage
Frame - Wood AC 2 Master
11
16.5
0 10.67 0 ,
176.1 ft'
0.3
0.23
0.3
0
DOORS
#
Omt
Door Type Space
Storms U-Value
Width
Height
Area
Ft
In
Ft In
1
W
Insulated AC 1 Main
None .2
2.7
8
21.4 ft2
WINDOWS
Orientation shown
is the entered, Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC U-Factor SHGC
Area
Depth
Separation
Int Shade
Screening
1
E 1
Metal Low-E Single Yes
1.07
0.3
32.5 ft2
1 ft 4 in
2 ft 0 in
None
None
2
E 1
Metal Low-E Single Yes
1
0.32
21.3 ft2
1 ft 4 in
2 ft 0 in
None
None
3
E 2
Metal Low-E Single Yes
1.07
0.3
32.5 ft2
1 ft 4 in
2 ft 0 in
None
None
4
E 3
Metal Low-E Single Yes
1.07
0.3
16.2 ft2
1 ft 4 in
2 it 0 in
None
None
5
E 4
Metal Low-E Single Yes
0.77
0.22
40.0 ft2
11 ft 0 in
3 ft 0 in
None
None
6
S 5
Metal Low-E Single Yes
1.07
0.3
22.7 112
1 ft 4 in
2 ft 0 in
None
None
7
S 5
Metal Low-E Single Yes
1.07
0.3
9.2 ft2
1 ft 4 in
2 ft 0 in
None
None
8
S 6
Metal Low-E Single Yes
0.77
0.22
40.0 ft2
18 It 0 in
3 ft 0 in
None
None
9
W 7
Metal Low-E Single Yes
1.07
0.3
117.0 ft2
1 ft 4 in
2 ft 0 in
None
None
_
10
E 8
Metal Low-E Single Yes
0.77
0.22
128.0 ft2
12 It 0 in
3 ft 0 in
None
None
11
E 8
Metal Low-E Single Yes
1
0.32
24.9 ft2
12 ft 0 in
1 ft 0 in
None
None
12
N 14
Metal Low-E Single Yes
1.07
0.3
13.7 ft2
1 ft 4 in
2 It 0 in
None
None
13
N 14
Metal Low-E Single Yes
1
0.32
9.2 ft2
1 ft 4 in
2 ft 0 in
None
None
2/4/2016 12:21 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 3 of 5
FORM R405-2014
r
WINDOWS
Orientation shown is the entered, Proposed orientation.
V #
Wall
Ornt ID Frame Panes NFRC
Overhang
U-Factor SHGC Area Depth Separation Int Shade
Screening
_ 14
15
16
17
N 14 Metal Low-E Single Yes
N 14 Metal Low-E Single Yes
S 15 Metal Low-E Single Yes
N 9 Metal Low-E Single Yes
1 0.32 16.2 ft2 1 it 4 in 2 ft 0 in None
1 0.32 6.7 ft2 1 ft 4 in 2 It 0 in None
1.07 0.3 13.7 ft2 1 ft 4 in 2 ft 0 in None
0.77 0.22 40.0 ft2 18 R 0 in 3 ft 0 in Drapes/blinds
None
None
None
None
GARAGE
#
Floor Area Ceiling Area
Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation
1
640 ft2 640 ft2
78 ft loft 1
INFILTRATION
# Scope
Method SLA
CFM 50 ELA EgLA ACH ACH 50
1 Wholehouse Proposed ACH(50) .000343
3316.5 182.07 342.41 .2571 5
HEATING SYSTEM r
#
System Type Subtype
Efficiency Capacity Block
Ducts
1
2
Electric Heat Pump Split
Electric Heat Pump Split
HSPF:8.2 55.5 kStu/hr 1
HSPF:8.2 17.6 kBtu/hr 2
sys#1
sys#2
COOLING SYSTEM
#
System Type Subtype
Efficiency Capacity Air Flow SHR Block
Ducts
1
2
Central Unit Split
Central Unit Split
SEER: 14 54.5 kBtu/hr 1900 cfm 0.75 1
SEER: 14 17.8 kBtu/hr 600 Cfm 0.75 2
sys#1
sys#2
HOT WATER SYSTEM
#
System Type SubType Location
EF Cap Use SetPnt Conservation
1
Electric None Garage
0.94 50 gal 70 gal 120 deg None
SOLAR HOT WATER SYSTEM
FSEC
Cert # Company Name
Collector Storage
System Model # Collector Model # Area Volume
FEF
None None
ft2
DUCTS
/
V #
—Supply-- —Return Air CFM 25 CFM25
Location R-Value Area Location Area Leakage Type Handler TOT OUT QN RLF
HVAC#
Heat Cool
1
2
Attic 6 360 ft2 Attic
Attic 6 220 ft2 Attic
80 ft2 Default Leakage AC 1 Main (Default) (Default)
120 ft2 Default Leakage AC 1 Main (Default) (Default)
1 1
2 2
2/4/2016 12:21 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 4 of 5
FORM R405-2014
TEMPERATURES
ProgramabllreXThermostat: Y
Fans:
Can
Coollng
Venting Jan
F:b
Feb
Mar
Mar
f
preiling
r0(
trX
r Aug
r0(
rfOct
is
�rX
Nov
Dec
0(
Dec
[
Apr [
May [
Jun
[ Jul
[
[Xj
Oct
[Xj
[
Thermostat Schedule:
HERS 2006
Reference
Hours
Schedule Type
1
2
3
4
5
6
7
8
9
10
11
12
Cooling (WD)
AM
78
78
78
78
78
78
78
78
80
80
80
80
PM
80
80
78
78
78
78
78
78
78
78
78
78
Cooling (WEH)
AM
78
78
78
78
78
78
78
78
78
78
78
78
PM
78
78
78
78
78
78
78
78
78
78
78
78
Heating (WD)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
Healing (WEH)
AM
66
66
66
66
66
68
68
68
68
68
68
68
PM
68
68
68
68
68
68
68
68
68
68
66
66
2/4/2016 12:21 PM EnergyGauge® USA- FlaRes2014 Section R405.4.1 Compliant Software Page 5 of 5
FORM R405-2014
r
ENERGY
PERFORMANCE LEVEL (EPL)
DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 98
The lower the EnergyPerformance Index, the more efficient the home.
Port St. Lucie, FL,
1. New construction or existing
New (From Plans) 9. Wall Types Insulation
Area
2. Single family or multiple family
Single-family a. Concrete Block - Int Insul, Exterior R=4.1
3321.00 ft2
b. Frame - Wood, Adjacent R=11.0
325.43 ft'
3. Number of units, if multiple family
1 c. N/A R=
ft2
4. Number of Bedrooms
4 d. N/A R=
ft2
5. Is this a worst case?
No 10. Ceiling Types Insulation
Area
a. Under Attic (Vented) R=38.0
3688.00 ft2
6. Conditioned floor area (ft2)
3688 b. N/A R=
ft2
7. Windows" Description
Area c. N/A R=
ft'
a. U-Factor: Sgl, U=1.07
257.35 ft2 1. Ducts
a. Sup: Attic, Ret: Attic, AH: AC 1 Main
R ft'
6 360
SHGC: SHGC=0.30
b. Sup: Attic, Ret: Attic, AH: AC 1 Main
6 220
b. U-Factor: Sgl, U=0.77
248.00 ft'
SHGC: SHGC=0.22
12. Cooling systems kBtu/hr
Efficiency
c. U-Factor: Sgl, U=1.00
78.17 ft2 a. Central Unit 54.5 SEER:14.00
SHGC: SHGC=0.32
b. Central Unit 17.8 SEER:14.00
d. U-Factor: N/A
ft2
SHGC:
13. Heating systems kBlu/hr
Efficiency
Area Weighted Average Overhang Depth:
a. Electric Heat Pump 55.5
7.076 ft.
HSPF:8.20
b. Electric Heat Pump 17.6
HSPF:8.20
Area Weighted Average SHGC:
0.269
8. Floor Types Insulaflon
Area 14. Hot water systems Cap:
50 gallons
a. Slab -On -Grade Edge Insulation R=0.0 3688.00 ft2 a. Electric
b. N/A R=
ft'
EF: 0.94
c. N/A R=
ft2 b. Conservation features
None
15. Credits
Pstat
I certify that this home has complied with the Florida Energy Efficiency Code fo
Construction through the above energy saving features which will be installed (
in this home before final inspection. Otherwise, a new EPL Display Card will bi
based on installed Code compliant feat s.
Builder Signature: 'ale: 3 I
Address of New Home: �?j2jl(p ��(�� �/Wpp� P( Cityity/FL Zip:
*Note: This is not a Building Energy Rating. If your Index is below 70, your home may qualify for energy efficient
mortgage (EEM) incentives if you obtain a Florida EnergyGauge Rating. Contact the EnergyGauge Hotline, at (321)
638-1492 or see the EnergyGauge web site at energygauge.com for information and a list of certified Raters. For
information about the Florida Building Code, Energy Conservation, contact the Florida Building Commission's
support staff.
**Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
2/4/2016 12:22 PM EnergyGauge® USA- FlaRes2014 - Section R405.4.1 Compliant Software Page 1 of 1
.e
Yorkshire Model
HVAC Load Calculations
for
Standard Pacific Homes
PVL7
1. jrjj JLJ171
RHVAC HVAC VAC L `tq.�L,
OADs
Prepared By:
Chris Wildroudt
Engineered Air LLC CACO45860
2520 N Andrews Ave Ext
Pompano Beach, FL 33064
954 974-7277
Wednesday, December 04, 2013
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA lanulf-I C
Rhvac - Residential & Light Commercial HVAC Loads - - - Elite. Software Development, Inc.
Engineered Air, LLC Yorkshire Model
Mar ale, FL 33063 ® _ _ Page 2
Project Report
General Project Information
Project Title: Yorkshire Model
Designed By: Chris Wildroudt
Project Date: 12-4-13
Client Name: Standard Pacific Homes
Company Name: Engineered Air LLC CACO45860
Company Representative: Chris Wildroudt
Company Address: 2520 N Andrews Ave Ext
Company City: Pompano Beach, FL 33064
Company Phone: 954 974-7277
Company Fax: 954 973-1883
I. Design Data
Reference City: West Palm Beach, Florida
Building Orientation: House faces East
Daily Temperature Range: Medium
Latitude: 26 Degrees
Elevation: 15 ft.
Altitude Factor: 0.999
Outdoor Outdoor Outdoor Indoor Indoor Grains
Dry Bulb Wet Bulb Rel.Hum Rel.Hum Dry Bulb Difference
Winter: 45 42.23 n/a n/a 70 n/a
Summer: 91 78 56% 50% 75 59
Check Figures
Total Building Supply CFM: 2,343 CFM Per Square ft.: 0.635
Square ft. of Room Area: 3,688 Square ft. Per Ton: 665
Volume (ft3) of Cond. Space: 39,351
BUIIdIn :Loads
Total Heating Required Including Ventilation Air: 43,384 Btuh 43.384 MBH
Total Sensible Gain: 51,529 Btuh 77 %
Total Latent Gain: 15,063 Btuh 23 %
Total Cooling Required Including Ventilation Air: 66,592 Btuh 5.55 Tons (Based On Sensible + Latent)
�NOteS;'£
�`.`:3
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
0
Rhvac- Residential& light Commercial HVAC,Loads
Engineered Air, LLC
_;- Elite Software Development, Inc.
Yorkshire Mode[
Margate, FL 33063 __. _�
_
..
Pa e 3
Total Building Summary Loads
Component
Area
$en
Let
Sen
Total'
Description
Quan
Loss
Gain
Gain
Gain
Lo-E French Door: Glazing-Low-E French Door, u-value
96
1,848
0
1,628
1,628
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
460
0
600
600
0.4, SHGC.0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,335
0
5,404
5,404
0.6, SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
770
0
956
956
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
282.8
4,238
0
5,931
5,931
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
0.59, SHGC 0.32
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
229
0
296
296
0.4, SHGC 0.31
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board 2389.4
8,543
0
5,569
5,569
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
304.1
311
0
311
311
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
1566
1,253
0
1,553
1,553
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pi: Floor -Slab on grade, No edge insulation, no
339
8,382
0
0
0
insulation below floor, any floor cover, passive, light
Subtotals for structure:
32,809
0
28,148
28,148
People:
7
2,100
1,960
4,060
Equipment:
4,700
5,100
9,800
Lighting:
1400
4,774
4,774
Ductwork:
3,905
3,230
4,638
7,868
Infiltration: Winter CFM: 243, Summer CFM: 125
6,670
5,033
2,191
7,224
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
4,718
4,718
Total Building Load Totals:
43,384
15,063
51,529
66,592
[Check Figures,
Total Building Supply CFM: 2,343
CFM Per Square ft.:
0.635
Square ft. of Room Area: 3,688
Square ft.
Per Ton:
665
Volume (ft3) of Cond. Space: 39,351
: BUildirili Loads'
Total Heating Required Including Ventilation Air: 43,384
Btuh
43.384
MBH
Total Sensible Gain: 51,529
Btuh
77
%
Total Latent Gain: 15,063
Btuh
23
%
Total Cooling Required Including Ventilation Air: 66,592
Btuh
5.55
Tons (Based On Sensible
+ Latent)
Notes
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
I
Rhvac- Residenbar&.Light Commercial HVAC Loads -
-
Elite Software: Development,Inc.
Engineered Air, LLC • _
®
Yorkshire Model
Margate, FL 33063
Pa e 4
S stem 1 AC 1 -First Floor Summary
Loads
Component
Area
San
Lat
San
Total
Description
Quan
Loss
Gain
Gain
_ Gain
Lo-E French Door: Glazing-Low-E French Door,u-value
96
1,848
0
1,628
1,628
0.77, SHGC 0.22
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
46.2
460
0
600
600
0.4, SHGC 0.31
Lo-E operable: Glazing-Low-E Operable Glass, u-value
155.8
2,335
0
5,404
5,404
0.62 SHGC 0.31
Lo-E French Door: Glazing-Low-E French Door, u-value
40
770
0
956
956
0.77, SHGC 0.22
Lo-E operable: Glazing-Low-E Operable Glass, u-value
148.8
2,230
0
2,404
2,404
0.6, SHGC 0.31
Lo-E S G D: Glazing -Low E Sliding Glass Door, u-value
288
4,248
0
5,708
5,708
0.592 SHGC 0.32
11J: Door -Metal - Fiberglass Core
21.4
192
0
192
192
13A-4ocs: Wall -Block, board insulation only, R-4 board
1756.6
6,280
0
4,095
4,095
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
128
131
0
131
131
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
697
558
0
691
691
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
248
6,132
0
0
0
insulation below floor, any floor cover, passive, light
dry soil
Subtotals for structure:
25,184
0
21,809
21,809
People:
5
1,500
1,400
2,900
Equipment:
4,000
3,500
7,500
Lighting:
1000
3,410
3,410
Ductwork:
2,995
924
3,536
4,460
Infiltration: Winter CFM: 185, Summer CFM: 95
5,098
3,847
1,675
52522
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
3,954
3,954
--
System 1 AC 1 - First Floor Load Totals:
33,277
10,271
39,283
49,555
'CheckFi ores
Supply CFM.1,787
CFM Per Square ft.:
0.634
Square ft. of Room Area: 2,819
Square ft.
Per Ton:
683
Volume (W) of Cond. Space: 30,079
S stem Loads :.,
Total Heating Required Including Ventilation Air:
33,277 Btuh
33.277
MBH
Total Sensible Gain:
39,283 Btuh
79
%
Total Latent Gain:
10,271 Btuh
21
%
Total Cooling Required Including Ventilation Air:
49,555 Btuh
4.13
Tons (Based On Sensible
+ Latent)
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads according to the manufacturer's
performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM
r+
Rhvac-Residential S Light Commercial. HVAC Loads:
Engineered Air,LLC
;
,.
Elite. Software Development, Inc.
Yorkshire. Model
Margate, FL 33053
Page
System 2 AC 2 - Second Floor Summaty Loads'
Component
Area
Sen
Laf
$en
Total
Descri tion
Quan
Loss
Gain
Gain
Gain
Lo-E operable: Glazing-Low-E Operable Glass, u-value
134
2,008
0
3,527
3,527
0.6, SHGC 0.31
Lo-E Fixed Glass: Glazing -Low E Fixed Glass, u-value
22.8
229
0
296
296
0.4, SHGC 0:31
13A-4ocs: Wall -Block, board insulation only, R-4 board
632.7
2,263
0
1,474
1,474
insulation, open core, siding finish
12E-Obw: Part -Frame, R-19 insulation in 2 x 6 stud
176.1
180
0
180
180
cavity, no board insulation, brick finish, wood studs
16D-30: Roof/Ceiling-Under Attic with Insulation on Attic
869
695
0
862
862
Floor (also use for Knee Walls and Partition
Ceilings), Vented Attic, No Radiant Barrier, Dark Tile,
Slate or Concrete, R-30 insulation
22A-pl: Floor -Slab on grade, No edge insulation, no
91
2,250
0
0
0
insulation below floor, any floor cover, passive, light
____dry soil
Subtotals for structure:
7,625
0
6,339
6,339
People:
2
600
560
1,160
Equipment:
700
1,600
2,300
Lighting:
400
1,364
1,364
Ductwork:
910
2,306
1,102
3,408
Infiltration: Winter CFM: 57, Summer CFM: 29
1,572
1,186
516
1,702
Ventilation: Winter CFM: 0, Summer CFM: 0
0
0
0
0
AED Excursion:
0
0
764
764
System 2 AC 2 - Second Floor Load Totals:
10,107
4,792
12,245
17,037
Check Figures
Supply CFM: 557
CFM Per Square ft.:
0.641
Square ft. of Room Area: 869
Square ft. Per Ton:
612
Volume (ft3) of Cond. Space: 9,272
[System Loads "
Total Heating Required Including Ventilation Air: 10,107
Btuh
10.107
MBH
Total Sensible Gain: 12,245
Btuh
72
%
Total Latent Gain: 4,792
Btuh
28
%
Total Cooling Required Including Ventilation Air: 17,037
Btuh
1.42
Tons (Based On Sensible + Latent)
Notes: ;
„s _".a.
s•,• �
Rhvac is an ACCA approved Manual J and Manual D computer program.
Calculations are performed per ACCA Manual J 8th Edition, Version 2, and
ACCA Manual D.
All computed results are estimates as building use and weather may vary.
Be sure to select a unit that meets both sensible and latent loads
according to the manufacturer's
performance data at
your design conditions.
S:\NEW CONSTRUCTION\Chris Elite Files\Stan Pac Prado Yorkshire.rh9 Wednesday, December 04, 2013, 2:35 PM