Loading...
HomeMy WebLinkAboutREVIEW COMMENTSPlanning 8 Development Services Building 8, Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 34982 Phone:(772)462-2172 Fax:(772)462-6"3 REVIEW COMMENTS PROPERTY INFORMATION Address: 13316 Nw Baywood PI City / State / Zip: Saint Lucie County, FI Parcel #: 4425-703-0041-000/4 Jurisdiction: Zoning: PUD Lot#: Permit Number: 1512-0408 Stories: Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS) CONTRACTOR INFORMATION Contractor Name: Richard M Woodley Business Name: Standard Pacific Of Florida Gp Inc Business Addr: 825 Coral Ridge Or City I State / Zip: Coral Springs, FI 33071 SCANNED BY St. Lucie County 1 Owner(s): Block: Automatic Sprinkler System? No Fax Number: 813-288-7610 Email: Tcollins@Stanpac.Com REVIEWS AND COMMENTS Review Type Status Reviewed By Date Started Date Comoleted Date Released DOCUMENTS MISSING PENDING Karen Nielsen 1212312015 12128/2015 Comment: THE ELECTRICAL AND MECHANICAL SUBS ARE NOT REGISTERED WITH SLC 1/42016 Comment: VEG PERMIT FILED UNDER "S" FOR STANDARD PACIFIC. NO FEE ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 1213012015 Comment: FRONT COUNTER REVIEW Comment: PLANS EXAMINER REVIEW Comment: 1/11/2016 1111/2016 Comment: Comment: 1/11/2016 1/1112016 Comment: 1/11/2016 Comment: 1/11/2016 Comment: COMPLETE Karen Nielsen 12123/2015 12123/2015 INCOMPLETE William Durden 1/1112016 1213012015 1212312015 • PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA ADMINISTRATIVE CODE • PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING CODE • THE TOTAL MODIFIED LOAD ON THE ENERGY CAL MUST BE LOWER OR EQUAL TO THE TOTAL BASE LINE LOADS. SEE SECTION R405.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION FIFTH EDITION. ENERGY CALC'S CALL OUT FOR NATURAL GAS WATER HEATER PLANS SHOW ELECTRIC WATER HEATER. PLEASE CORRECT. AREA WEIGHTED AVERAGE OVERHANG DEPTH ON THE ENERGY CALC'S IS INCORRECT PLEASE CORRECT. ENERGY CALC SHOWS A 0.620 FOR THE EF OF THE WATERHEATER PLEASE SEE TABLE C404.2 OF THE ' 2014 FLORIDA ENERGY CODE. Planning & Development Services Building & Code Regulation Division 2300 Virginia Avenue Fort Pierce, FL 3082 Phone:(772)462-2172 Fax:(772)462.6"3 REVIEW COMMENTS Page 2 Comment: PLEASE CI ARIFYTHP RPACFR FI nnPC ANr] WAI I C CFCTVIN r1N THE FNFRr:V r.Al ClR IT r:A11 C M IT "' "`".. SECOND FLOOR CONDITIOND SPACE, PLANS ONLY SHOW SINGLE STORY BUILDING. 1/11/2016 Comment: 110 MPH ENGINEER DESIGN CERTIFICATION REQUIRED FOR GARAGE DOOR, PER NOTES ON SHEET GN. 1/11/2016 Comment: U-FACTOR FOR THE WINDOWS ON THE ENERGY CALC'S ARE HIGH PLEASE CORRECT. ZONING REVIEW INCOMPLETE Jeffrey Johnson 12128/2015 1212812015 12/28/2015 Comment: PLEASE REVISE SURVEY TO SHOW AN ELEVATION AT THE CROWN OF THE ROAD.