REVIEW COMMENTS
PROPERTY INFORMATION
Address: 13316 Nw Baywood PI
City / State / Zip: Saint Lucie County, FI
Parcel #: 4425-703-0041-000/4 Jurisdiction:
Zoning: PUD
Lot#:
Permit Number: 1512-0408 Stories:
Permit Type: BUILDING RESIDENTIAL (SFR UP TO 2 FLOORS)
CONTRACTOR INFORMATION
Contractor Name: Richard M Woodley
Business Name: Standard Pacific Of Florida Gp Inc
Business Addr: 825 Coral Ridge Or
City I State / Zip: Coral Springs, FI 33071
SCANNED
BY
St. Lucie County
1
Owner(s):
Block:
Automatic Sprinkler System? No
Fax Number: 813-288-7610
Email: Tcollins@Stanpac.Com
REVIEWS AND COMMENTS
Review Type Status Reviewed By Date Started Date Comoleted Date Released
DOCUMENTS MISSING PENDING Karen Nielsen 1212312015
12128/2015 Comment: THE ELECTRICAL AND MECHANICAL SUBS ARE NOT REGISTERED WITH SLC
1/42016 Comment: VEG PERMIT FILED UNDER "S" FOR STANDARD PACIFIC. NO FEE
ENVIRONMENTAL REVIEW COMPLETE Ben Balcer 1213012015
Comment:
FRONT COUNTER REVIEW
Comment:
PLANS EXAMINER REVIEW
Comment:
1/11/2016
1111/2016 Comment:
Comment:
1/11/2016
1/1112016 Comment:
1/11/2016 Comment:
1/11/2016 Comment:
COMPLETE Karen Nielsen 12123/2015 12123/2015
INCOMPLETE William Durden 1/1112016
1213012015
1212312015
• PLEASE FURNISH THE MANUFACTURES TRUSS PLACEMENT DRAWINGS IN DUPLICATE REVIEWED AND
APPROVED BY THE DESIGN PERSON OF RECORD IN ACCORDANCE WITH 61G15-30.005 OF THE FLORIDA
ADMINISTRATIVE CODE
• PLEASE FURNISH TRUSS ENGINEERING IN DUPLICATE PER 107.2.1 OF THE 2014 FLORIDA BUILDING
CODE
• THE TOTAL MODIFIED LOAD ON THE ENERGY CAL MUST BE LOWER OR EQUAL TO THE TOTAL BASE LINE
LOADS. SEE SECTION R405.3 OF THE 2014 FLORIDA BUILDING CODE ENERGY CONSERVATION FIFTH
EDITION.
ENERGY CALC'S CALL OUT FOR NATURAL GAS WATER HEATER PLANS SHOW ELECTRIC WATER HEATER.
PLEASE CORRECT.
AREA WEIGHTED AVERAGE OVERHANG DEPTH ON THE ENERGY CALC'S IS INCORRECT PLEASE
CORRECT.
ENERGY CALC SHOWS A 0.620 FOR THE EF OF THE WATERHEATER PLEASE SEE TABLE C404.2 OF THE
' 2014 FLORIDA ENERGY CODE.
Planning & Development Services
Building & Code Regulation Division
2300 Virginia Avenue
Fort Pierce, FL 3082
Phone:(772)462-2172 Fax:(772)462.6"3
REVIEW COMMENTS
Page 2
Comment: PLEASE CI ARIFYTHP RPACFR FI nnPC ANr] WAI I C CFCTVIN r1N THE FNFRr:V r.Al ClR IT r:A11 C M IT
"' "`".. SECOND FLOOR CONDITIOND SPACE, PLANS ONLY SHOW SINGLE STORY BUILDING.
1/11/2016 Comment: 110 MPH ENGINEER DESIGN CERTIFICATION REQUIRED FOR GARAGE DOOR, PER NOTES ON SHEET GN.
1/11/2016 Comment: U-FACTOR FOR THE WINDOWS ON THE ENERGY CALC'S ARE HIGH PLEASE CORRECT.
ZONING REVIEW INCOMPLETE Jeffrey Johnson
12128/2015 1212812015
12/28/2015 Comment: PLEASE REVISE SURVEY TO SHOW AN ELEVATION AT THE CROWN OF THE ROAD.