Loading...
HomeMy WebLinkAboutREVISIONSa Go a* OFFICE USE ONLY: DATE FILED: REVISION FEE: PERMIT RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION SCANNED 2300 VIRGINIA AVENUE BY FORT PIERCE, FL 34982-5652 (772) 462-1553 St. Lucie County APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE Riverbend ADDRESS: 13316 NW Baywood Place Lot 36 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. 4. 5. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC1506052 BUSINESS NAME: Standard Pa QUALIFIERS NAME: Scott Harsh ADDRESS: 825 Coral Ridge Drive ST. LUCIE COUNTY CERT. #: CITY: Coral Springs STATE: F1 ZIP: 33071 PHONE(DAYTIME): 054_739_2990 FAX: 954-424—AA40 OWNERIBUILDER INFORMATION: NAME: Standard Pacific Homes ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: Fl ZIP: 33U7i PHONE: 954_232_2290 FAX: 954-434-8840. ARCHITECT/ENGINEER INFORMATION: NAME: AB Design ADDRESS: 1191 East Newport Center Suite 207 CITY: Deerfield Beach STATE: Fl ZIP: 33442 PHONE (DAYTIME): 954-482-0957 FAX: 954-708-2468 SLCCC: 9/23/09 Revised 04/26/2010 i e sa.r Z- 2 i L e < 4 q4t 1�� � ;+��°' 'aka` e yt C • � OFFICE USE ONLY: DATE FILED: PERMIT # (,REVISION FEE: ti 5 • O RECEIPT # PLANNING & DEVELOPMENT SERVICES SCANNED BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE - BY FORT PIERCE, FL 34982-5652 St. Lucie County (772) 462-1553 APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE Riverbend 1512-0408 ADDRESS: 13316 NW Baywood Place Lot 36 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 3. CONTRACTOR INFORMATION: STATE ofFLREG./CERT.#: CGC1506052 ST. LUCIE COUNTY CERT. #: BUSINESS NAME: Standard Pacific Homes QUALIFIERS NAME: Scott Harala ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: F1 ZIP: 33071 PHONE (DAYTIME): 954-272-229n FAX: 954-424—RR4n 4. OWNER/BUILDER INFORMATION: NAME: Standard Pacific Homes ADDRESS: 825 Coral Ridge Drive CITY: Coral Springs STATE: F1 ZIP: 33071 PHONE: 954-212-2290 FAX: 954-434-8840 5. NAME: AB Design ADDRESS: 1191 East Newport Center Suite CITY: 1)eprfield R .a .h PHONE (DAYTIME): 954-eac_nos� 7 SLCCC: 9123/09 Revised OV26/2010 STATE: REVISI L1Y: A R C H I T E C T S Design Groupl��. October 20, 2016 St. Lucie County Planning & Development Services Building & Code Regulation Division County 2300 Virginia Avenue Fort Pierce, FL. 34982 Attn: Building Plan Examiner RE: Standard Pacific Homes Riverbend Lot 36 Permit No. # BLDG 1512-0408 Dear Sir/Madam, This letter serves as my response to comments: 1. Revised home to sealed attic per builder. A. Roof vent calculations crossed off as they are not applicable. See delta 1 on sheet A2C. B. Added R-20 spray foam insulation at roof trusses and removed R-30 blown -in insulation at ceiling. See delta 1 on sheets D1 and D2. If you have any questions please contact me at (407) 774-6078. Sincerely, James Cantwell Florida Architect #12079 3 Gw,' tj n 1441 N. Ronald Reagan Blvd. • Longwood, FL 32750 • Phone: I AA0003325 www.abdesigngroup.com RECEI'.'-DAPR 202016 L . T OFFICE USE ONLY: L DATE FILED: -I 1a01 tro VISION FEE: -15.10 6 PERMIT # 151 a - a `t o4 RECEIPT # 11 Ali 411 -A PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION 2300 VIRGINIA AVENUE SCANNED FORT PIERCE, FL 34982-5652 BY (772) 462-1553 St. Lucie County APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION 1. LOCATION/SITE Riverbend ADDRESS: 1512-0408 13316 NW Bavwbod Place Lot 46 2. DETAILED DESCRIPTION OF PROJECT REVISIONS: 0 5. CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: CGC1506304 BUSINESS NAME: Standard Pa QUALIFIERS NAME: Richard We ADDRESS: 825 Coral Ridge Drive ST. LUCIE COUNTY CERT. #: 28420 CTIry: Coral Springs STATE: F1 ZIP: 33071 PHONE (DAYTIME): og4-s7s-711-7 FAX: 954-575-7324 OWNER/BUILDER INFORMATION: NAME: ADDRESS: CITY: PHONE: Standard Pacific Homes 825 Coral Ridge Drive Coral Springs STATE: Fl ZI 954-575-7337 FAX: 954-575-7324 ARCHITECTBNGINEER INFORMATION: NAME: AB Design ADDRESS: _1191 East Newport Center Suite CITY: neerfield Reach PHONE (DAYTIME): 954-489-0957 SLCCC: 9/23/09 Revised 04/26/2010 STATE: Fl ZIP: 33442 FAX: 954-708-2468 DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION SECTION: 071100—THERMAL INSULATION SCANNED BY St. Lucie County REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON, TEXAS 76011 EVALUATION SUBJECT: SEALECTIOW 500 SPRAY -APPLIED POLYURETHANE FOAM INSULATION IC��, cIC��� IC' C+=�� � Look for thetrtrusted marks of Confform`ityl 12014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence" of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attribtdes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to anyfinding or other matter in this report, or as to arty product covered by the report.A° Copyright© 20161CC Evaluation Service, LLC. All rights reserved. ICC-ES Evaluation Report ESR-1172 Reissued February 2016 This report is subject to renewal February 2017. www:icc-es.org 1 (800) 423-6587 i (562) 699-0543 A Subsidiary of the International Code Council® DIVISION: 07 00 00—THERMAL AND MOISTURE PROTECTION Section: 07 21 00—Thermal Insulation REPORT HOLDER: DEMILEC (USA) INC. 3315 EAST DIVISION STREET ARLINGTON, TEXAS 76011 (817) 640-4900 www.damileausa.com inforddemile cusa.co m EVALUATION SUBJECT: SEALECTION® 500 SPRAY -APPLIED POLYURETHANE FOAM INSULATION 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: ■ 2015. 2012 and 2009 International Budding Code® (IBC) ■ 2015, 2012 and 2009 International Residential Code® (IRC) ■ 2015. 2012 and 2009 International Energy Conservation Code®(IECC) ■ 2013 Abu Dhabi International Building Code (ADIBC)r tTha ADIBC Is based on the 2009 IBC. 2009 IBC code sections referenced In this report are the same sections in the ADIBC. ■ Other Codes (see Section 8.0) Properties evaluated: ■ Surface -burning characteristics ■ Physical properties ■ Thermal resistance ■ Attic and crawl space installation ■ Air permeability ■ Fire -resistance -rated construction ■ Exterior walls in Type I through IV construction 1.2 Evaluation to the following green green standard: ■ 2008 ICC 700 National Green Building Standard*!" (ICC 700-2008) Attributes verified: ■ See Section 2.0 2.0 USES material in Type I, 11. III, IV and Type V construction under the IBC and in dwellings under the IRC. The Insulation Is for use in wall cavities, Floor/ceiling assemblies, or attics and crawl spaces when installed In accordance with Section 4.0. Under the IRC and the 2015 IBC, the Insulation may be used as air -impermeable insulation when installed in accordance with Section 3.4. The insulation may be used in nonload-bearing, fire -resistance - rated walls when construction is in accordance with Section 4.5. The attributes of the insulation have been verified as conforming to the provisions of ICC 700-2008 Section 703.2.1.1.1(c) as an air impermeable insulation. Note that decisions on compliance for those areas rest with the user of this report The user is advised of the project -specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report These codes or standards often provide supplemental information as guidance. 3.0 DESCRIPTION 3.1 Materials: SEALECTION® 500 spray -applied foam insulation is semirigid, low -density, polyurethane foam plastic that is Installed as a component of Floor/ceiling and wall assemblies. The insulation is a two -component spray.foam plastic with a nominal in -place density of 0.5 pcf (8 kg/m3). The insulation is produced in the field by combining a polymeric isocyanate (A-PMDI component, A -Side ISO) with a polymeric resin (SEALECTION® 500 B-Side component). The insulation liquid components are supplied in 55-gallon (208 L) drums and/or 250-gallon (946 L) totes and must be stored at temperatures between 50OF (100C) and 100OF (380C). The liquid components have a shelf life of one year when stored in factory -sealed containers at these temperatures. 3.2 Surface -burning Characteristics: The Insulation, at a maximum thickness of 6 inches (162 mm) and a nominal density of 0.5 pcf (8 kg/m), has a Flame -spread index of 25 or less and a smoke -developed index of 450 or less when tested in accordance with ASTM E84. Greater thicknesses are recognized as described in Sections 4.3 and 4.4. SEALECTIONe 500 thickness is not limited when separated from the Interior of the building by a prescriptive thermal barrier as complying with the IBC or IRC and as described in Section 4.3.1. 3.3 Thermal Resistance, R-values: SEALECTION® 500 spray -applied polyurethane foam The insulation has thermal resistance (R-value) at a mean Insulation is used as a nonstructural thermal Insulating temperature of 75OF (240C) as shown in Table 1. IMESEvalmnion Repmtram nor to be co almedw reprurntingaalheila or atyotlaranr/bnln no,spwfteallyaddmned, nor arc thry to be eamimed as m; endorsement ofthe subject ofthe report or a rernmmetdmlonforIts we.71,em 6 no varrmoyby ICC Eeshmilm, SMce, UC rpress or Implied. or 1�L-�.'.p.- (Z tomwfinding or other matter In lids report. or as 0 aryprohwl meendby the mpon. 00 —_ Copyright 6 20161CC evalua0on Service, I.I.C. All rights reserved. Page 1 of 6 ESR4172 I Most IMde/yAccepted and Trusted Page 2 of 5 3.4 Air Permeability: SEALECTION® 500 spray -applied polyurethane foam insulation, at a minimum thickness of 3.0 inches (76 mm), is considered air -impermeable insulation in accordance with 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4) and 2015 IBC Section 1203.3, based on testing in accordance with ASTM E2178. 3.5 BlazelokT I134lntumescent Coating: BlazelokT"^ IB4 intumescent coating, manufactured by TPRZ Corporation, is a one -component, water -based liquid coating with specific gravity of 1.3. BlazelokT"i I134 is supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) drums and has a shelf life of one year when stored in factory -sealed containers at temperatures between 450F (7°C) and 90'F (320C). 3.6 BlazelokT TS Intumescent Coating: BlazelokTm TB intumescent coating, manufactured by TPRZ Corporation, is a one -component, water -based liquid coating with specific gravity of 1.3. BlazelokT TB is supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) drums and has a shelf life of one year when stored in factory -sealed containers at temperatures between 45"F (7°C) and 90OF (320C). 3.7 BlazelokT"' TBX Intumescent Coating: BlazelokT"" TBX intumescent coating, manufactured by TPRZ Corporation, is a one -component, water -based liquid coating with specific gravity of 1.4. BlazelokT'" TBX is supplied in 5-gallon (19 L) pails and/or 55-gallon (208 L) drums and has a shelf life of one year when stored in factory -sealed containers at temperatures between 45°F (7°C) and 90"F (320C). 3.8 Andek Firegard Intumescent Coating: Andek Firegard intumescent coating, manufactured by Andek Corporation, is a one -component water -based coating with specific gravity of 1.37. Andek Firegard is supplied in 5-gallon (19 L) pails and has a shelf life of one year when stored in factory -sealed containers at temperatures between 450F (70C) and 90OF (320C). 3.9 No -Burn Plus XD Intumescent Coating: No -Bum® Plus XD intumescent coating, manufactured by No -Bum, Inc., is a translucent aqueous liquid in 1- and 5-gallon (3.8 and 18.8 L) pails and 55-gallon (208 L) drums. The coating has a shelf life of three years when stored in a factory -sealed container at temperatures between 40OF (4.5°C) and 90OF (320C). 3.10 DC 315 Fireproof Paint: DC 315, manufactured by International Fireproof Technology, Inc., is a one -component, water -based, liquid coating with a specific gravity of 1.3. DC 315 is supplied in 5-gallon (19 L) pails and/or 55-gallon drums and has a shelf life of one year when stored in unopened factory - sealed containers between 50°F (10°C) to 80°F (27°C). 4.0 INSTALLATION 4.1 General: SEALECTION® 500 spray -applied foam insulation must be installed in accordance with the Center for Polyurethane Industries Guidance on Best Practices for the Installation of Spray Polyurethane Foam, the manufacturer's published technical data sheet and product application guide and this report. A copy of each document must be available at all times on the jobsite during installation. 4.2 Application: The SEALECTION® 500 insulation is spray -applied on the jobsite using a volumetric positive displacement pump as identified in the Demilec application guide. The insulation must be applied when the ambient temperature is greater than 230F (-50C). The insulation must not be used in areas that have a maximum in-service temperature greater than 180"F (820C). The foam plastic must not be used in electrical outlet or junction boxes or in contact with water, rain or soil. The foam plastic must not be sprayed onto a substrate that is wet, or covered with frost or ice, loose scales, rust, oil, or grease. The insulation must be protected from the weather during and after application. The insulation may be applied to the maximum thickness in a single pass. Where insulation is used as an air - impermeable insulation, such as in unvented attic assemblies under 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4) or 2015 IBC Section 1203.3, the insulation must be installed at a minimum thickness of 3.0 inches (76 mm). 4.3 Thermal Barrier: 4.3.1 Application with a Prescriptive Thermal Barrier: SEALECTION® 500 spray foam insulation must be separated from the interior of the building by an approved thermal barrier of '/2-inch4hick (12.7 mm) gypsum wallboard or an equivalent 15-minute thermal barrier complying with, and installed in accordance with, IBC Section 2603.4 or IRC Section R316.4, as applicable, except where insulation is in an attic or crawl space as described in Section 4.4. SEALECTION® 500 thickness is not limited when separated from the interior of the building by a prescriptive thermal barrier as complying with the IBC or IRC. 4.3.2 Application without a Prescriptive Thermal Barrier: The prescriptive 15-minute thermal barrier may be omitted when installation is in accordance with this section and Table 2. SEALECTION® 500 spray foam insulation and BlazelokT TB, BlazelokT" TBX or DC 315 intumescent coating may be spray -applied to the interior facing of walls, the underside of roof sheathing or roof rafters, and in crawl spaces, and may be left exposed as an interior finish without a prescribed 15-minute thermal barrier or ignition barrier. The foam plastic insulation thickness must not exceed thicknesses stated in Table 2. All foam surfaces must be covered with intumescent coating, described in Section 3.6, at the minimum thicknesses stated in Table 2. The intumescent coating must be spray -applied over the insulation In accordance with the coating manufacturer's instructions and this report at a rate stated in Table 2 to obtain the recommended minimum dry film thickness noted in this section. 4.4 Ignition Barrier -Attics and Crawl Spaces: 4.4.1 Application with a Prescriptive Ignition Barrier: When SEALECTION® 500 spray foam insulation is installed within attics or crawl spaces where entry is made only for service of utilities, an ignition barrier must be installed in accordance with IBC Section 2603.4.1.6 or IRC Section R316.5.3 or R316.5.4, as applicable. The ignition barrier must be consistent with the requirements for the type of construction required by the applicable code, and must be installed in a manner so the foam plastic insulation is not exposed. SEALECTION® 500 spray - applied foam insulation as described in this section may be installed in unvented attics in accordance with 2015 IBC Section 1203.3 or 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4). 4.4.2 Application without a Prescriptive Ignition Barrier: 4.4.2.1 General: SEALECTION® 500 spray -applied foam insulation may be installed in attics and crawl spaces, ESR-1172 I Most Widely Accepted and Trusted Page 3 of 5 _ without a prescriptive ignition barrier as described in IBC Section 2603.4.1.6 and IRC Sections R316.5.3 and R316.5.4, in accordance with Section 4.4.2.2, 4.4.2.3, 4.4.2.4, or 4.4.2.5. when all of the following conditions apply. a. Entry to the attic or crawl space is only to service utilities, and no storage is permitted. b. There are no interconnected attic or crawl space areas. c. Air in the attic or crawl space is not circulated to other parts of the building. d. Under -floor (crawl space) ventilation is provided when required by 2015 IBC Section 1203.4 (2012 and 2009 IBC Section 1203.3) or IRC Section R408.1, as applicable. e. Attic ventilation is provided when required by IBC Section 1203.2 or IRC Section R806, except when air - impermeable insulation is permitted in unvented attics in accordance with 2015 IBC Section 1203.3 or 2015 and 2012 IRC Section R806.5 (2009 IRC Section R806.4). f. Combustion air is provided in accordance with IMC (International Mechanical Code®) Section 701. 4.4.2.2 The insulation must be covered on all surfaces with a fire protective coating at the minimum thickness set forth in Table 3. 4.4.2.3 The maximum installed thickness of the insulation must not exceed the thicknesses set forth in Table 3. 4.4.2.4 The coating must be applied over the insulation in accordance with the coating manufacturer's instructions and this report 4.4.2.6 Use on Attic Floors: SEALECTION® 500 spray - applied foam insulation may be installed at a maximum thickness between and over the joists in attic floors as set forth in Table 3. All exposed foam plastic surfaces must be covered with a minimum nominal thickness of the fire protective coatings as set forth in Table 3. The intumescent coatings must be applied over the insulation in accordance with the coating manufacturer's instructions and this report. 4.5 One -hour Fire -resistance -rated Wall Assemblies (Nonload-bearing): SEALECTION® 500 foam insulation may be used as a component of a one -hour fire -resistance -rated, nonload- bearing wall assembly as described in this section (Section 4.5). 4.5.1 Interior and Exterior Face: One layer of %-inch- thick (16 mm), Type X gypsum wallboard complying with ASTM C36 or ASTM C1396 is installed on the interior and exterior side of nominally 2-by-6, No. 1, Southern yellow pine wood studs spaced 16 inches (406 mm) on center. The wallboard is attached with 15/s-inch-long (41 mm), coarse -thread drywall screws located 8 inches (203 mm) on center along the perimeter and 12 inches on center (305 mm) in the field of the wallboard. Wallboard joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Fastener heads must also be treated with joint compound in accordance with ASTM C840 or GA-216. 4.5.2 Stud Cavity: A nominally 5'/24nch (140 mm) thickness of SEALECTION® 500 foam insulation is spray - applied in all stud cavities. 4.6 Exterior Walls of Type I, II,111 and IV Construction: When used on exterior walls of Type 1, II, III and IV construction, the SEALECTION® 500 foam insulation must comply with Section 2603.5 of the IBC at a maximum thickness of 3% inches (92 mm), when installed per the manufacturer's published product application guide and this section. The potential heat of Demilec SEALECTION® 500 spray polyurethane foam insulation is 496 Btu/flz (5.6 MJ/m2) per inch of thickness when tested in accordance with NFPA 25R 4.6.1 Nonload-bearing NFPA 285-tested Wall Assembly: 4.6.1.1 Interior Face: One layer of s/a-inch-thick (16 mm), Type X gypsum wallboard complying with ASTM C36 or ASTM C1396 is installed with the long dimension perpendicular to 35/a-inch-deep (92 mm), 20 gage steel studs spaced a maximum of 24 inches (609 mm) on center. The wallboard is attached with 1'/4-inch-long (31.8 mm), bugle head screws located 8 inches (203 mm) on center along the perimeter and 12 inches on center (305 mm) in the field of the wallboard. Wallboard joints must be taped and treated with joint compound in accordance with ASTM C840 or GA-216. Fastener heads must also be treated with joint compound in accordance with ASTM C840 or GA-216. 4.6.1.2 Stud Cavity: SEALECTION® 500 foam insulation, in a maximum thickness of 35/e inches (92 mm), is spray - applied in all stud cavities. 4.6.1.3 Exterior Face: One layer of 5/e-inch-thick (16 mm� GP DensGlasss sheathing attached to steel studs using 1 /4-inch-long (31.8 mm), self -tapping screws spaced 8 inches (203 mm) on center along the perimeter and 12 inches on center (305 mm) in the field of the sheathing. Details of the exterior wall covering must be provided by the report holder, designer or specifier to the code official, with a fire engineering analysis demonstrating that the addition of the wall covering will not negatively affect conformance of the assembly with the requirements of IBC Section 2603.5. 5.0 CONDITIONS OF USE SEALECTION® 500 spray foam insulation described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The products must be installed in accordance with the Center for Polyurethane Industries "Guidance on Best Practices for the Installation of Spray Polyurethane Foam", the manufacturer's published technical data sheet and product application guide, this evaluation report and the applicable code. If there are any conflicts between the manufacturer's published installation instructions and this report, this report governs. 5.2 The insulation must be separated from the interior of the building by an approved 15-minute thermal barrier, except when installation is as described in Sections 4.3.2 or 4.4.1 through 4.4.2.5. 5.3 The insulation must not exceed the thicknesses noted in Sections 3.2, 4.2, 4.3, 4.4, 4.5, and 4.6. 5.4 The insulation must be protected from exposure to weather during and after application. 5.5- The ' insulation must be applied by contractors authorized by Demilec (USA) Inc. 5.6 Use of the insulation in areas where the probability of termite infestation is "very heavy' must be in accordance with IRC Section R318.4 or 2015 and 2009 IBC Section 2603.8 (2012 IBC Section 2603.9), as applicable. ESR-1172 I Most Widely Accepted and Trusted Page 4 of 5 5.7 When use is on exterior walls of buildings of Type I, II, III, and IV, construction must be as described in Section 4.6. 5.8 See Section 4.5 for the fire -resistance -rated wall assemblies. 5.9 Jobsite certification and labeling of the insulation must comply with 2015 IRC Section N1101.10, 2012 IRC Section N1101.14, 2015 or 2012 IECC Sections C303.1, R303.1 and R401.3 12009 IECC Section 303.1 and 401.31, as applicable. 5.10 The insulation is produced in Arlington, Texas, under a quality -control program with inspections by ICC-ES. 6.0 EVIDENCE SUBMITTED 6.1 Data in accordance with the ICC-ES Acceptance Criteria for Spray -applied Foam Plastic Insulation (AC377), dated May 2015, including reports of tests in accordance with Appendix X. 6.2 Reports of fire propagation characteristics tests in accordance with NFPA 285. 6.3 Reports of air leakage testing in accordance with ASTM E283. 6.4 Reports of air permeance tests in accordance with ASTM E2178. 6.5 Reports of room corner tests in accordance with NFPA 286. 6.6 Reports of tests in accordance with ASTM El19. 6.7 Reports of potential heat tests in accordance with NFPA 259. 7.0 IDENTIFICATION Components of the spray foam insulation are identified with the manufacturers name (Demilec (USA) Inc.), address and telephone number, the product name (SEALECTION® A-PMDI or SEALECTION® 500 B- Side); use instructions; the density; the Flame -spread and smoke -developed indices; the date of manufacture; thermal resistance values; the evaluation report number (ESR-1172); and the name of the inspection agency (Intertek Testing Services NA). Each pail of the Blazelokm IB4 and the BlazelokTM TB or Blazelokr TBX intumescent coating is labeled with the manufacturers name (TPR2 Corporation), the product name, and use instructions. Each pail of Andek Corporations Firegard intumescent coating is labeled with the manufacturers name (Andek Corporation) and address, the product trade name, and use instructions. No -Burn" Plus XD intumescent coating is identified with the manufacturers name (No -Burn, Inc) and address, the product trade name, and use instructions. Each pail of DC315 is labeled with the manufacturers name (International Fireproof Technology Inc.), address, product trade name and use instructions. 8.0 OTHER CODES 8.1 Evaluation Scope: In addition to the codes referenced in Section 1.0, the products recognized in this report have also been evaluated in accordance with the following codes: ■ 2006 International Building Code (2006 IBC) ■ 2005International Residential Code (2006 IRC) ■ 2006 international Energy Conservation Code® (2006 IECC) ■ 2003 International Building Code (2003 IBC) ■ 2003 International Residential Codeo (2003 IRC) ■ 2003 International Energy Conservation Code (2003 IECC) 8.2 Uses: The products comply with the above -mentioned codes as described in Sections 2.0 through 7.0 of this report except as noted below: ■ Application with a Prescriptive Thermal Barrier: See Section 4.3.1, except the approved thermal barrier must be installed in accordance with Section R314.4 of the 2006 IRC or Section R314.1.12 of the 2003 IRC. ■ Application without a Prescriptive Thermal Barrier: See Section 4.3.2. ■ Application with a Prescriptive Ignition Barrier: See Section 4.4.1, except attics must be vented in accordance with Section 1203.2 of the 2006 and 2003 IBC or Section R806 of the 2003 IRC, and crawl space ventilation must be in accordance with IBC Section 1203.3 of the 2006 and 2003 IBC or IRC Section R408, as applicable. Additionally, an ignition barrier must be installed in accordance with Sections R314.5.3 or R314.5.3 of the 2006 IRC or Section R314.2.3 of the 2003 IRC, as applicable. ■ Application without a Prescriptive Ignition Barrier: See Section 4.4.2, except attics must be vented in accordance with Section 1203.2 of the 2006 and 2003 IBC or Section R806 of the IRC, and crawl space ventilation must be in accordance with Section 1203.3 of the 2006 and 2003 IBC or IRC Section R408, as applicable. ■ Protection against Termites: See Section 5.6, except use of the insulation in areas where the probability of termite infestation is "very heavy' must be in accordance with Section R320.5 of the 2006 IRC or Section R320.4 of the 2003 IRC. ■ Jobsite Certification and Labeling: See Section 5.9, except jobsite certification and labeling must comply with Sections 102.1.1 and 102.1.11, as applicable, of the 2006 IECC. ESR-1172 I Most Widely Accepted and Trusted Page 6 of 5 TABLE 1—THERMAL RESISTANCE (R-VALUES) THICKNESS (Inches) R-VALUE ('F.fe.hlBtu) 1 3.8 3.5 13 4 15 5.5 21 7 27 9.5 36 10 38 11.5 44 14 52 For SI:1 inch = 25.4 mm; 1 °F.ft'.h/Btu = 0.176110 °K.m2/W. 'R-values are calculated based on tested K-values at 1- and 4-Inch thicknesses. TABLE 2—USE OF INSULATION WITHOUT A PRESCRIPTIVE THERMAL BARRIER Maximum Insulation Maximum Insulation Fire Protective Coating (Applied to all Foam Surfaces Coating Thickness (In.) Thickness (in.) Minimum Coating Dry Minimum Coating Wet I Minimum Vertical Surfaces Ceiling Surfaces Film Thickness Imils Film Thickness mils Application Rate Blazelok TB 5 /z 10 14 25 1 1 al/82 ft Blazelok TBX 7 /s i t h 11 17 1 a1/85 DC315 7 /2 111, 12 18 1 1 al/90 For SI: 1 inch-- 25.4 mm; 1 gal = 3.785 L; 1 hz = 0.093 rr?. TABLE 3—ATTIC OR CRAWL SPACE ASSEMBLIES WITHOUT A PRESCRIPTIVE IGNITION BARRIER Maximum Insulation Maximum Insulation Fire Protective Coating Coating Thickness (In.) Thickness (in.) (Applied to all Foam Surfaces Minimum Coating Dry Minimum Coating Minimum Vertical Surfaces and Ceiling Surfaces Attic Floors Film Thickness Wet Film Thickness I Application Rate Blazelok IB4 94 11 /. 5 9 1 al/175 Andek Fire and 911 11 / 10 20 1 11/100 f No -Bum Plus XD 911 14 / 6 10 1 al/160 ft DC 315 7 l 11 h 3 4 1 al/7? ft For SI: 1 inch-- 25.4 mm; 1 gal = 3.785 L; 162 = 0.093 0. SEALECTION'IO- jiBMILEC Sealection® 500 Is a two component, open cell, spray applied, semi -rigid polyurethane foam system. This product is a fully water blown foam system with a low in -place density with excellent adhesion to various substrates and to Itself. Sealection 500 Incorporates the single phase solution technology developed by Demilec for excellent shelf life and consistent processing. Sealection 500 complies with the Intent of the International Code Council's residential and commercial building codes for spray polyurethane foam plastic Insulation. Sealection 500 has been approved by the EcoLogo (formerly Environmental Choice) Program of Canada and Is an NAHB Green Approved Product. Sealection 500 meets the USDA guidelines for Incidental food contact MIRROPERTIrS.. Ypc ASTM D 1622 Density 0.45 - 0.5 Ib/ft' 7.2 - 8 kg/m' ASTM C 518 Aged Thermal Resistance (R-value @ 1 inch) 3.81 Wh-F/BTU 0.67 Km'/W Air Leakage (air impermeable IAW 2006, 2009 & 2012 IRC, IBC & IECC requirements) ASTM E 283 Air Permeance @ 75 Pa @ 3.5" Sustained wind load for 60 minutes @ 1000 Pa (90 mph wind) Gust wind load test @ 3000 Pa 060 mph wind) 0.001 L/sm' No Damage No Damage ASTM E 2178 Air Permeance @ 50 Pa @ 3.5" Air Permeance @ 100 Pa @ 3.5" Air Permeance @ 300 Pa @ 3.5" 0.001 L/sm' 0.003 L/sm' 0.008 L/sm' ASTM E 96 Water Vapor Permeance @ 3.5" Water Vapor Permeance @ 5.5" Water Vapor Permeance @ T' Water Vapor Permeance @ 10" Qualifies as a Class III vapor retarder at normal installed thicknesses 6.33 perms 4.03 perms 3.17 perms 2.20 perms 362 ng/Pa•s•m' 231 ng/Pa•s•m' 181 ng/Pa•s•m' 126 ng/Pa•s•m' ASTM E 413 Sound Transmission Class (STC) (see website for assembly specs) 49 - 51 ASTM C 423 Noise Reduction Coefficient (NRC) 75 CAN/ULC-S774-09 VOC Emissions Standard 24 hr re -occupancy time, 2 hour ven(:ilation period before PPE is no longer required ASTM D 1621 Compressive Strength 0.7 psi 4.8 kPa ASTM D 1623 Tensile Strength 5.6 psi 38.6 kPa Surface Burning Characteristics, 6" thick Class I ASTM E 84 Flame Spread Index 21 Smoke Developed 216 Ignition Barrier - Compliant with 2006, 2009 & 2012 IBC and IRC, and ICC-ES AC-377 Appendix X, for use In attics and crawl spaces with: NFPA 286 Blazelok" 1134 at 3 mils dry film thickness, 5 mils wet film thickness, or - Pass Andek Firegard at 10 mils dry film thickness, 16 mils wet film thickness, or No Burn Plus XD at 4 mils dry film thickness NFPA 286 Thermal Barrier - Compliant with the 2006, 2009 & 2012 IBC and IRC, as an interior finish without a 15 minute thermal barrier with BlazelokTM TBX at 11 mils dry film thickness. Pass Compliant with the 2006, 2009 & 2012 IBC for exterior walls of Type I, II, III and IV buildings of NFPA 285 any height See ICC-ES ESR 1172, Section 4.6 for specific assembly. Contact the Demilec Pass Engineering Department for assistance with alternate assemblies. ASTM E 970 Sealection 500 may be left exposed on attic floors up to 14" thick. Pass Non load -bearing, I hour, wall assembly test. See ICC-ES ESR 1172, Section 4.5 for specific ASTM E 119 assembly. Contact the Demilec Engineering Department for assistance with alternate Pass assemblies. ASTM D 1929 Ignition Properties (spontaneous Ignition temperature) 1040°F (560-C) ••o Cream Time Gel Time Tack Free Time End of Rise 1-2 seconds 3-4seconds 6-7 seconds 6-7 seconds 3315 E Division Street Arlington, TX 76011 Sealection 500 Technical Data Sheet Phone (817) 640-4900, Toll Free (877) 336-4532 Last Revision 9.22-16 Fax (817) 633-2000, Info@Demilec.com, www.Demilec.com Pagel of 2 SEALECTIONO 04 PROPERTY J'; •� !A PMDI_ISQCYANATE SEALECTION�500-RESiN,I . Color Brown Amber Viscosity @ 77°F (25°C) 180 - 220 cps 150 - 300 cps Specific Gravity 1.24 1.08 -1.12 Shelf Life of unopened drum properly stored 12 months 12 months Storage Temperature 50 -100°F (10 - 38°C) 50 -100°F (10 - 38°C) Mixing Ratio (volume) 1:1 1.1 'See SIDS for more Information. -[REC•M M ENDED.PROGESSI• r Initial Recirculating Setpoint Temperature 90 -100°F 32 - 38°C Initial Primary Heater Setpoint Temperature 130°F 54°C Initial Hose Heat Setpoint Temperature 130°F '54°C Initial Processing Setpoint Pressure 1200 psi 8274 kPa Substrate & Ambient Temperature > 23°F > -5°C Moisture Content of Substrate s 19% s 19% Moisture Content of Concrete Concrete must be cured, dry and free of dust and form release agents. 'Foam application temperatures and pressures can vary widely depending on temperature, humidity, elevation, substrate, equipment and other factors. While processing, the applicator must continuously observe the characteristics of the sprayed foam and adjust processing temperatures and pressures to maintain proper cell structure, adhesion, cohesion and general foam quality. It Is the sole responsibility of the applicator to process and apply Sealection 500 within specification. General Requirements: Equipment must be capable of delivering the proper ratio (1:1 by volume) of polymeric Isocyanate (PMDI) and POlyol blend at adequate temperatures and spray pressures. Substrate must be at least 5 degrees above dew point, with best processing results when ambient humidity Is below 80%. Substrate must also be free of moisture (dew or frost), grease, oil, solvents and other materials that would adversely affect adhesion of the polyurethane foam. Sealection 500 must be separated from the Interior of the building by an approved thermal barrier or an approved finish material equivalent to a thermal barrier In accordance with applicable codes. Sealection 500 must be sprayed at a minimum thickness of 3" per pass. This product must not be used when the continuous service temperature of the substrate or foam Is below -609F (-51°C) or above 180°F (82°C). Sealection 500 should not be used in contact with bulk water, below grade or to cover Flexible ductwork Disclaimer- The Information herein is to assist customers In determining whether our products are suitable for their applications. We request that customers Inspect and test our products before use and satisfy themselves as to contents and suitability. Nothing herein shall constitute a warranty, expressed or Implied, Including any warranty of merchantability or fitness, nor Is protection from any law or patent Inferred. All patent rights are reserved. The foam product is combustible and must be protected In accordance with applicable codes. Protect from direct flame and spark contact, around hot work for example. The exclusive remedy for all proven claims is replacement of our materials. `eVlto,1. , 4 V C ` �y V fMeE 3315 E. Division Street, Arlington, TX 76011 Sealection 500 Technic Phone (817) 640-4900, Toll Free (877) 336-4532 Last Re Fax (817) 633.2000. Info@Demilec.com, wwwMemileccom