HomeMy WebLinkAboutEVALUATION REPORTSEXTERIOR RESEARCH & DESIGN, U.C.
rtificate of Authorization 09503
TRINITY ERD SCANNE�e353 Christian Street
BY Oxford, CT06478
Lucie County (203) 262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A429 0.10.-1 - 2
PO Box 70 F bOT -R2
Rutherford, NJ07070 Date of Issuance:10/23/2012
(800)516-1485 Revision 2:09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code. The product described herein has been evaluated for
compliance with the 6th Edition (2017) Florida Building Code sections noted herein.
DESCRIPTION: TRI-BUILT Modified Bitumen Roof Systems
LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinity( ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with 'each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 4, plus a 26-page Appendix.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE1983
ffl
"The facsimile O��9syea��p�1/ringS�p as authorized by Robert Nieminen,
EMMIf V�tse. as an eiectromoiN signed
CERTIFICATION OF wearINDEPENDENCE: g // I inn M"FUMP
1. Exterior Research & Design, LLC. d b a TrinityERD does not have, n e CMQ� 9A�n a financial interest
in any company manufacturing or distributing products it evaluates. ST. LUCID OVN;�If
2. Exterior Research & Design, LLC. d/b/a Trinity I ERD is not owned, operated or con rolle by a c pany manufacturing or
distributing products it evaluates. BOC
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manuf nng or distributing products for
which the evaluation reports are being.issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
5. This is a building code evaluation. Neither Trinity) ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
File Copy
��
The following notes apply to the situ ms outlined herein:
1. The roof system evaluation herein pertains to abcveEeck mof components. Roof decks and structural membenshalI be in accordance with FBC requirements to the satisfaction of the Authority Having Jurisdiction.
Wad resistance of them of deck shall be documented through proper roddiW and/or FBCAppmvaI documentation.
2. Insulation/ base sheet fasteners shall be of sufficient length for the following deckengagement
1 Wood: Minimum 0.75-inch penetration.
:Steel: Minimum D.TS-inch penetration and engage the topflute ofthe steel deck.
i Structural concrete: Minimum 1-inch embedment into pilot hole in accordance withfactener manufacturers published installation instructions.
or_
3. Unless otherwise noted, insulation may be any one layer orcombinaiion of polyisoryanurete, polystyrene, wood fiberboard, pedite, gypsum-basetl roof board or mineral -wool roof board that meets the CA
requirements of FA C. Rule 61020.3 and is documented as meeting FBC 15BS.1 aM, farf0am plastic, FBC Chapter 26, when Installed with the roof cover.
Exterior Research and Deslgn,LLG d/b/aT,ImtylERU - I+' - + '+ Evaluation Report A42970.10.12-R2 for FL36022-RZ
Certificate of Authorization 119503 .. ., I—a6s"EDITION(20121 FBC NON-HVHZ EVALUATION Revision 2: 09/2512017
Prepared by: Robert Martinet, PE-59166 TRI-BUILT Mod0led Bitumen Roof systems;(800) 516-1485 Appendix 1, Page 1 of 26
\! I RINITY I ERD
15. Unless otherwise noted, refer to the following references for bonded base, ply or cap sheet applications.
_ TARLE SCTRI-BUILTRoot•COVERS
Reference
layer
Material
Application
BP -AA
Base Ply
FBC Approved ASTM D4601, Type 11
(Base and Ply sheets, Asphalt -Applied)
HA at 2040lbs/square
Ply
FBC Approved ASTM D2128, Type IV or M
SBS-AA
(SBS, Asphalt -Applied)
fop Ply
TriBuilt SBS Granular
HA at 2040lbs/square
SBS-TA -
jSBS, Torch -A plied)
Cap Ply
TIIBuilt SBS Granular
Torch -Applied
SBS SA
Base,y
n se
ISBS,SLf�! Ire(dng)
Self-Atlheting
`ay]
nBO RSA`SBS
APP-TA
Base Ply or Ply
TriBuilt APP Smooth
(APP,Tomh-Applied)
Cap ply
TnBuiR APP Smooth,TriBuilt APP Granular
Torch -Applied
APP-SA
(APP, Self-Adhenng)
Cap Ply
TriBuilt SAAPP Cap
Self -Adhering
16. Vapor harder options for use over structural concrete deck followed by adhered insulation carry the following Maximum Design Pressure(MDP)limitations. The lesser of the MDP listings below vs. those in Table 3A
applies:
VPPOP BPPRIEA OPEIONSi SrRVCTIPALCOXp1EiE DEIXi AaNEREDINSUlAT10NPEx TParF3A _ - -
Option#
Primer
Vapor Barrier
Insulation Adhesive
MOP Ipsf)
Type
Attach
VB-1.
ASTM D41
TriBuilt SASBSBaza
Self -Adhering
Inca-Stik or CR-20,12-inch o.c.
-60.0
VB-2.
ASTM D41
TriBuilt SA SBS Gp
Self -Adhering
Insta-Stik, 12-inch o.c.
-75.0
VB-3.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
M illannium One Step Foamable Adhesive,12-inch ox.
-157.5
VB-4.
ASTM D41
TriBuilt SA SBS Cap
Self -Adhering
CR-20, 12-inch o.c.
-270.0
VB-5.
ASTM D41
TriBuilt SA SBS Base
Self -Adhering
Millennium One Step Foamable Adhesive, Millennium PG-1 Pump Glade
Adhesive, OlyBond 500 or CR-20,12-inch o.c.
.290.0
IT. Dens Deck shall be field -primed with PG100 prior to self -adhering membrane application. Refer to tables herein for other priming requirements.
18. 'MDP'=Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads. Refer to FBC 1609 for determination of design wind loads.
Exterior Research and Design, U.C. d/b/a TrinitVI ERD Evaluation Report A42970.10.12-R2 for FL36027-R2
Certificate of Authorization #95D3 6'x EDITION (2017) FBC NON-HVHZ EVALUATION Revision 2:09/25/2017
Prepared by: Robert Niernmen, PE-59166 TRI-BUILT Modified Bitumen Roof Systems; IB00) 516-14S5 Appendix 1, Page 3 of 26
. . t
V I RINIIY I ERD
- TABLE IE-2: WOOD DECKS-NEWCONSTRUCDON,REROOF(TMn-0FF)oRREcovm ,
SYSfEMTVPEE: NON -INSULATED; MECHANICALLYATTACHED BASESHEET, BONDED ROOFCOVER
System
- Base Sheet
Roof Cover(Noti
MOP
No.
Oerk ]Note ll
Base
Fasteners
Attach
Base Ply
CaPPIy
(PA
Min.odAinch
Polyglass Elartobase, Polyglass Elastobace
OMGFIat Bottom Plates
12-inc and
iquainch lapd,
(Optional) One or
SBS.AA,SBS-
W-1
se,MB
Poty,Pse,
xwithe)whh
Roofr914, ip wst HDekfaz[g14
ste,inch
o.c. in two, equally spaced, staggered
two,
more BP-AAar
TA, APP TA
-525
24-mIhdatmax.
24inch spans
Firestone
Plly Base Par
ruFaA
or TruFart MD-3 with TruFart HD
or MP-3
center rows
App.TA
28,T, ko Glae Base AFGLASa
Ply 28; Tamko Glass Baze or GAFGLAS g15
Min. 19/32 nch
=+ -..-], A—V -•:�
PolyglasSEl rtebawofP h9axx -
r4
' Dskfast Hex with Dekfart P34 orT.Fast MP
121nho 1 4vrxE hDand12ch
�-+yi +�-yam++"si"T^
tvro aquallysp oad lagg wed
" I--
D cer more SBS
SDSSA,APP-
`•r --
SA 565-TAOF
-52.5"
W-2
plywood [max
.ar---x�� rmtr- ,,,"
'-
Elastabase Poly with poly top dace
3with TruFast HD
'a-�-- -
SA
24-inch spans
_
_
sent _sue- -
Min.19/32-inch
Polyglass Elastobace or Palyglass
OMG Flat Bottom Plate, (,.are) with
12-inch o.c. in 4-inch lapand 12-inch
O.C. In two, equally spaced, staggered
(Optional)Oneor�
more BP -AA or
SBS-AA, SBS-
'.60.0
W-3
plywood at max.
24-inch spans
Elastobase Poly
Roofgrip#12
center rows
APP-TA
TA, APP-TA
Min. 19/32-inch
Poryelass Elartobaseor Polyglass
OMG Flat Bottom Plates(square) with
12-inch o.c. in 4-Inch lap and 124nch
o.c. in two, equally spaced, staggered
I
Oneormore 585-
SB SA,APP
SA,SBS-TAar
-60.0'
W-0
plywood at max.
24inchsP.ns
Elartobase Pory with poly top surface
Roofgrip gl2
center rows
SA
APP-TA
_ - - TABU IF: WOOD DECKS -NEW CONSTRUCTION on REROOF(IIAR-0rc)
._ _
SYSTEM TYPEF:NON-INSU_IATED,BONOED RODE COVER .
System
Roof Cover (Note 15)
MOP
loin[Treatment
Base Ply
Ply
Cap Ply
No.
perk
Primer
(Pd)
Min. 15/32-inch plywood
SBS-SA
(Optional)5BS-SA or
SBS-SA,APP-SA,SB5-TA
-90.0
W-5
at max. 24-inch spans
(Optional)ASTM O41
None
APPTA
or APP-TA
Min. 15/32-Inch plywood
Plywood joints are covered with 4-inch wide strips of TriBuilt SA
TriBuilt SA 5B5 Base
(Option.])SB5-SA or
SBS-SA, APP-SA, SBS-TA
915
W-6
at max. 24-inch spans
(Optional)ASTM D41
SBS Base, rolled into place to create continuous bond.
APP-TA
or APP-TA
Exterior Research and Design, U.C. d/b/a Trinity]ERD
Certificate of Authorization g9S03
Prepared by: Robert Nieminen, PE-59166
t
Evaluation Report A42970.10.12-R2 for FL16021-RZ
6r"EDITI ON (2019] FBC NON-HVHZ EVALUATION Revision 2:09/25/2017
MI -BUILT Modified Bitumen Roof Systems; (800) 516-1485 Appendix 1, Page 8 of 26
CSUCK Engineering ScaBY�o
�N. ' St. Lucie County
SpPc:1c2 . y Structural a ry J"IFIL-nnq CSUCJS Ix CertJJfoate offu thorrsation #kU
Evaluation Report
"Ultra HT Wind & Water Seal'""'
Roof Underlayment
Manufacturer:
MFM Building Products Corp.
• 525 Orange Street
Coshocton, Ohio 49812
(740) 622-2645
for
Florida Product Approval
# FL 11842.3 R4
Florida Building Code 6th Edition (2017)
Method: 1- D
Category: Roofing
Sub - Category: Underlayment
Product:
Description:
Prepared by:
James L. Buckner, P.E., SECB
Florida Professional Engineer#31242
Florida Evaluation ANE ID: 1916
Project Manager: Diana Galloway
Report No.17-131-UHT-ER
(Revises 15-115-UHT--FJ2 FLU847,5 R3)
Date: 07/09/17
Contents:
Evaluation Report Pages 1-5
"Ultra HT Wind &Water Seal-"
Self -Adhered Underlayment
Facsimile of digital copy signed by
James L Buckner, P e
Electronimllysigned and sealed documents shall
cornplywhh the provisions of FAC Rule 63G35-23.
Co®E
ST. Ll
�Lt1` 1iSUCJlr���i
� :'�uceNyF'•..t� i
* No 33IZ42 * `_
--V: 1 rl
2017.08.2814-49:1"4'00'
c6tlaq Inc. dha CBUCICEngineering File copy Phone: (561) 491-9927 • Emall: cbuokgacbuckinc.net • Website: w .cbucklncmet
Business: 1374 Community. Dr., Jupiter, FL33458 • Corp/Malling: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL33062
100I100'd SWELM(W 1e10H010A)(aX0L 61,0ZtSLl40
FL #: FL 12842.3 R4
Date: 07/09/17
�B 6�! R� CK Englnsprino Report No.: 2 of
-UHT-ER
Page 2 of 5
SpL-4=alfy Structural E:n(JW VhCprirlq CSUCK;M Cc t;%cote ofAurhorizartan98064
Manufacturer.
MFM Building Products Corp.
525 Orange Street
Coshocton, Ohio 43812
(740) 622-2645
www.mfmbo.com
Product Name:
"Ultra HTWind & Water Sealr"
Product Category:
Roofing
Product Sub -Category
Underlayment
Compliance Method: . State Product Approval Rule 61G20-3.005 (1) (d)
Product Description: "Ultra HT Wind & Water Seal'"" is self -adhering membrane composed of a white,
non -slip cross -laminated polymer film, laminated to a rubberized asphalt adhesive
with a split release liner designed for use as a roof underlayment in high
temperature conditions.
Product Material / Material Type. Styrene Butadiene Styrene (SBS)
Standards: Material shall comply with ASTM D 1970 per Florida Building Code FBC 6th Edition
(2017), Chapter 15.
Product Dlmension(s) Roll Size: 36 In. x 67 ft. rolls
Thickness:45 mils (nominal)
Substrate(s): "Ultra HT Wind & Water Seal'" has been evaluated for application to the
following substrates (Design of support is outside the scope of this evaluation):
• Plywood
• Dens Deck
installation: General Installation Instructions:
"Ultra HT Wind & Water Sear' shall be installed In accordance with the attached
installation method and in compliance with applicable code sections of the FBC
6th Edition (2017), subject to the Limitations and Conditions of Use listed in this
Evaluation Report.
Refer to installation details at the end of this report. Refer to manufacturer's
Installation instructions as a supplemental guide for attachment.
10011.00A SBOBueZ AD le;aWawal3x36£OL 6LOZlSL1b0
FL#: FL11942.3 R4
L '' Date: 07/09/17
Repo
SUCK F=nOneerinq . Pagert No.: 3 of 51-UHT ER
SpE+Clc5H%J SrrL=rUrd1 Ertg1ncPE* nc2 CBUCK1ncCeMcateofAurhorhorfon#B064
Performance Standards: The product described herein has demonstrated compliance with:
• ASTM D 197o-15a — Specjflcation Self -adhering Polymer Modified
Bituminous Sheet Materials Used as Steep Roof Underloymentfor Ice Dam
Protection
Standards Equivalency: The ASTM D 1970-01 standard version used to test the product meets the
prescribed standards in ASTM D 1970-15a standard version adopted by the
Florida Building Code 6+th Edition (2017) for use as evaluated in this report.
Code Compliance: The product(s) described herein have demonstrated compliance with the
performance standards listed above as referenced in the current Florida Building
Code.
Evaluation Report Scope: This product has been evaluated in compliance with the building envelope
requirements of the Florida Building Code, as related to the scope section to
Florida Product Approval Rule 61G20-3.001.
Product Limitations and • Deck shall be in compliance with applicable building code.
Conditions of Use: a Minimum slope shall be 2:12 or greater.
• Installation is limited to use with 'approved roof coverings that are
mechanically fastened through the underlayment and is attached to the
sheathing or rafters.
• Not to be applied over active solvents or sealants, EPDM rubber or products
containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
General Limitations and • Scope of "Limitations and Conditions of Use for this evaluation:
Conditions of Use: This evaluation report for "Optional Statewide Approval' contains technical
documentation, specifications and installation method(s) which include
"Umitations and Conditions of Use" throughout the report in accordance with
Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is
the authority to approve products under "Optional Statewide Approval'.
• Option for application outside "Limitations and Conditions of Use
Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific
approval by the local authorities having jurisdiction in accordance with the
alternate methods and materials authorized in the Code". Any modification of
the product as evaluated in this report and approved by the Florida Building
Commission is outside the scope of this evaluation and will be the
responsibility of others_
• This report is a building code product evaluation per FLPE rule (FAC) 61G15-36
to comply with Florida product approval rule (FAC) 61G20-3. This evaluation
report is part of the Florida Building Commission approval for the listed code
related criteria. This report by James Buckner, P.E. and CBUCK Engineering Is
1.00iL00'd smaZLBZLLAD 1010H8luaJIx36£:01. 6LOZiSL1t+0
FL #: FL 11942.3 R4
Date: 07/09/17
CBUCK &nginvied oc� Report No.:17-131-UHT-ER
6J� Page 4of5
Sp2dslty Structural Enginw=prinq C8U.CK, Ix CerflJrmte ofAuthorrzaHon N8069
not a design certification of code compliance construction submittal
documentation, per FBC section 107, for any Individual structure, she specific
or permit design.
♦ Design of support system Is outside the scope of this report.
• Fire Classification is outside the scope of Rule 614320-3, and is therefore not
included in this evaluation.
• This evaluation report does not evaluate the use of this product for use in the
High Velocity Hurricane Zone code section. (Dade & Broward Counties)
Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in
accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for
manufacturing under a quality assurance program audited by an approved quality
assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA
1924).
Referenced Data: L ASTM D 1970-01 Test
By.PRI Construction Materials Technologies, Inc.
(FBCOrganization ID#TST1S56)
Report No. MFM-039-02-01, Date: 8/15/3.3
2. Equivalency of Test Standard Certification
By James L Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
3. Quality Assurance
Keystone Certifications, Inc. (FBC Organization ID# QUA 1824)
MFM Building Products Corp. Licensee #335
4. Certification of Independence
By James L Buckner, P.E. @ CBUCK Engineering
(FBC Organization # ANE 1916)
1.0011007d smiluBZLL(mo IP40W 0waJlx3 W01. 6LOZIS L/b0
FL M FL 11842.3 RC
Date.,
07/09/17
/gyp
Engia swrinQ�
RepoSUCK
PagertNo.=5o
51-UHT-ER
SpEacles li Srruc:ftirdl
EngfnL.rinq CBUCK Ina Cert&Ote of Avthanzoriwi#8064
MFM Building Products Corp.
Ultra HT Wind & Water Seal
Self -Adhered Roofing Underlayment
General Installation instructions:
• Product to be applied directly to a clean dry surface.
• Prime any weathered surfaces. Dens Deck must be primed with asphalt base primer.
• Starting at the low point of the deck, peel back 12"of the release liner, align the membrane and press into
place onto roof deck.
• Adhesive is pressure -activated, so press firmly into place using uniform pressure with a 2-3" heavy steel or
rubber roller to seams and overlap.
Overlap end laps a minimum of 6". Side laps must be a minimum of 3".
• Store product in the carton in a dry place until readyto use. Keep product out of direct sunlight.
• Apply membrane only In fair weather when the air, surface and membrane are at a minimum temperature
of: ST F
• Not to be applied overactive solvents or sealants, EPDM rubber or products containing silicone.
• Do not expose product to direct sunlight for more than 60 days.
"Ultra HT Wind & Water Seal "' shall be installed in accordance with the attached installation method and in
compliance with applicable code sections of the FBC 6th Edition (2017), subject to the Umitations and
Conditions of Use listed in this Evaluation Report.
Refer to installation details at the end.of this report. Refer to manufacturer's installation instructions as a
supplemental guide for attachment.
Product Illustrations
ULTRA HT
+�*' wINa.BWA'rlclt:5�F5t:":
1.00I1,00'd scoBZLB (AD 1140H01110Ax300:01, 6LOZISLI40