HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017
FILE `i 9
FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION
Florida Department of Business-m Pr$fs - egulation - Residential Performance Method
Project Name: Pauley Residence
APR 17 2019
B ilder Name:
SCANNED
Street: XXX Seminole Road
P rtnit office: St. Lucie County
City, Slate, Zip: Fort Pierce, FL, 34951
P rmit Number:
BY
Owner: Pauley Residence
S_T. Lucie County, Permitting sdiction: St Lucie County
St. Lucie County
Design Location: FL, Fort Pierce
County: St. Lucie (Florida Climate Zone 2 )
1. New construction or existing
New (From Plans)
9. Wall Types (1576.0 soft.)
Insulation Area
2. Single family or multiple family
Single-family
a. Concrete Block - Ext Insul, Exterior
R=4.1 1392.00 ft'
b. Frame - Wood, Adjacent
R=11.0 184.00 ft2
3. Number of units, if multiple family
1
c. N/A
R= ft2
4. Number of Bedrooms
3
d. N/A
R= ft.
S. Is this a worst case?
No
10. Ceiling Types (1845.0 sqft.)
Insulation Area
a. Under Attic (Vented)
R=38.0 1845.00 ft2
6. Conditioned floor area above grade (ft�
1845
b. N/A
R= ft2
Conditioned floor area below grade (ft2)
0
c. N/A
R= ft2
11. Ducts
R 112
7. Windows(174.0 soft.) Description
Area
a. Sup: Attic, Ret: Hall, AH: Laundry
6 115
a. U-Factor: Dbl, U=0.65
174.00 ft2
SHGC: SHGC=0.25
b;. U-Factor: N/A
ft2
12. Cooling systems
kBtu/hr Efficiency
:'' SHGC:
a. Central Unit
35.4 SEER:16.00
c. U-Factor: N/A
ft2
SHGC:
13. Heating systems
kBtu/hr Efficiency
d. U-Factor. N/A
ft2
a. Electric Strip Heat
27.0 COP:1.00
SHGC:
Area Weighted Average Overhang Depth:
4.726 ft.
Area Weighted Average SHGC:
0.250
14. Hot water systems
8. Floor Types (1845.0 sgft.)
Insulation Area
a. Electric
Cap: 50 gallons
a. Slab -On -Grade Edge Insulation
R=0.0 1845.00 ft2
b. Conservation features
EF: 0.950
b. N/A
R= ft2
None
c. NIA
R= ft2
15. Credits
CF, Patel
Glass/Floor Area: 0.094
Total Proposed Modified Loads: 53.34
PASS
Total Baseline
Loads: 58.07
I hereby certify that the plans and specifications covered by
Review of the plans and
STg7F
this calculation are in compliance with the Florida Energy
specifications covered by this
�FRIiE
�y 0
Code.
calculation indirates compliance
'
with the Florida Energy Code.
PREPAR BX
�'
Before construction is completed
uP1 eb
DATE:
this building will be inspected for
compliance with Section 553.908
I hereby certify that this building desi ed, ' in compliance
Florida Statutes.
with the Florida Energy Code.
CAD W6
OWNER/AGENT:
BUILDING OFFICIAL:
DATE:
DATE:
- Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as
)certified factory -sealed in accordance with R403.3.2.1.
- Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an
.+:nvelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2).
4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
PROJECT
Title: Pauley Residence
Bedrooms: 3
Address Type:
Street Address
Building Type: User
Conditioned Area: 1845
Lot #
Owner Name: Pauley Residence
Total Stories: 1
Block/Subdivision:
# of Units: 1
Worst Case: No
PlatBook:
Builder Name:
Rotate Angle: 0
Street:
XXX Seminole Road
Permit Office: St. Lucie County
Cross Ventilation: No
County:
St. Lucie
Jurisdiction: St. Lucie County
Whole House Fan: No
City, State, Zip:
Fort Pierce ,
Family Type: Single-family
FL, 34951
New/Ebsting: New (From Plans)
Comment:
CLIMATE
/
Design Temp
Int Design Temp Heating Design Daily Temp
V Design Location
TMY Site 97.5 %
2.5 %
Winter
Summer Degree Days Moisture
Range
FL, Fort Pierce FL VERO_BEACH_MUNI 39
90
70
75 299
62
Low
BLOCKS
Number Name
Area Volume
1 Entire House
1845 14760
SPACES
Number Name
Area Volume Kitchen Occupants
Bedrooms
Infil ID Finished Cooled
Heated
1 Master Bath
140 1120 No
0
1 Yes
Yes
Yes
2 Master Closet
80 640 No
0
1 No
Yes
Yes
3 Master Bedroom
298 2384 No
2
1
1 Yes
Yes
Yes
4 Kitchen
252 2016 Yes
2
1 Yes
Yes
Yes
5 Dining
216 1728 No
2
1 Yes
Yes
Yes
6 Family Room
338 2704 No
2
1 Yes
Yes
Yes
7 Bedroom 3
154 1232 No
1
1
1 Yes
Yes
Yes
8 Laundry
60 480 No
0
1 No
Yes
Yes
9 Bathroom
60 480 No
0
1 Yes
Yes
Yes
10 Bedroom 2
199 1592 No
1
1
1 Yes
Yes
Yes
11 Hall
48 384 No
0
1 No
Yes
Yes
FLOORS
# Floor Type
Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile Wood
Carpet
1 Slab -On -Grade Edge Insulatio
Master Bath 24 It 0
140 ft'
_
1 0
0
2 Slab -On -Grade Edge Insulatio
Master Closet 1 ft 0
80 ft'
_
1 0
0
3 Slab -On -Grade Edge Insulatio
Master Bedroom 47 ft 0
298 ft'
_
1 0
0
4 Slab -On -Grade Edge Insulatio
Kitchen 14 ft 0
252 ft'
_
1 0
0
5 Slab -On -Grade Edge Insulatio
Dining 12 ft 0
216 ft'
—
1 0
0
6 Slab -On -Grade Edge Insulatio
Family Room 26 ft 0
338 ft'
_
1 0
0
4/10/2019 4:29 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
FLOORS
#
Floor Type Space Perimeter Perimeter R-Value
Area
Joist R-Value
Tile
Wood Carpet
7 Slab -On -Grade Edge Insulatio Bedroom 3 14 ft 0
164 ft2
_
1
0
0
8 Slab -On -Grade Edge Insulago Laundry 1 ft
0
60 ft2
-
1
0
0
9 Slab -On -Grade Edge Insulago Bathroom 1 ft
0
60 ft2
_
1
0
0
10SIab-On-Grade Edge Insulato Bedroom 2 36 ft 0
199 ft'
-
1
0
0
11SIab-On-Grade Edge Insulatto Hall 1 ft
0
48 ft'
-
1
0
0
ROOF
/
Roof
Gable
Roof
Solar SA
Emitt
Emift
Deck
Pitch
V
#
Type Materials Area
Area
Color
Absor. Tested
Tested
Insul.
(deg)
1
Hip Composition shingles 2063 ft2
0 ft2 Medium
0.6
No
0.9
No
0
26.6
ATTIC
/
V
#
Type Ventilation
Vent Ratio (1 In)
Area
RBS
IRCC
1
Full attic Vented
150
1845 ft2
N
N
CEILING
#
Ceiling Type Space
R-Value
Ins Type
Area
Framing Frac Truss Type
1
Under Attic (Vented) Master Bath
38
Batt
140 ft'
0.1
Wood
_
2
Under Attic (Vented) Master Closet
38
Batt
80 ft2
0.1
Wood
_
3
Under Attic (Vented) Master Bedroom
38
Batt
298 ft2
0.1
Wood
_
4
Under Attic (Vented) Kitchen
38
Batt
252 ft2
0.1
Wood
5
Under Attic (Vented) Dining
38
Batt
216 ft2
0.1
Wood
6
Under Attic (Vented) Family Room
38
Batt
338 ft2
0.1
Wood
_
7
Under Attic (Vented) Bedroom 3
38
Batt
154 ft2
0.1
Wood
8
Under Attic (Vented) Laundry
38
Batt
60 ft2
0.1
Wood
_
9
Under Attic (Vented) Bathroom
38
Batt
60 ft2
0.1
Wood
10
Under Attic (Vented) Bedroom 2
38
Batt
199 ft'
0.1
Wood
11
Under Attic (Vented) Hall
38
Batt
48 ft2
0.1
Wood
WALLS
Adjacent Cavity Width
Space
Height
Sheathing Framing
Solar
Below
_ 1
E
Exterior Concrete Block- Ext InsMaster Bath
4.1 10
0 8
0
80.0 ft2
0
0
0.6
0
_ 2
S
Exterior Concrete Block- Ext InsMaster Bath
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
_ 3
N
Exterior Concrete Block- Ext ln3d6ster Bedro
4.1 14
0 8
0
112.0 ft'
0
0
0.6
0
_ 4
E
Exterior Concrete Block - Ext InSdhster Bedro
4.1 27
0 8
0
216.0 ft2
0
0
0.6
0
5
W
Exterior Concrete Block - Ext InMaster Bedro
4.1 6
0 8
0
48.0 ft2
0
0
0.6
0
_ 6
S
Exterior Concrete Block- Ext Insul Kitchen
4.1 14
0 8
0
112.0 ft2
0
0
0.6
0
-7
S
Exterior Concrete Block- Ext Insul Dining
4.1 12
0 8
0
96.0 ft2
0
0
0.6
0
8
N
Exterior Concrete Block- Ext InSf9mily Room
4.1 26
0 8
0
208.0 ft'
0
0
0.6
0
4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6
• - - I010-1 M1111fi I ill V X943.I X03I.W11i i 74lS-laIII
WALLS
Adjacent Space
Cavity Width
Height
Sheathing Framing Solar Below
_ 9
S
Exterior
Concrete Block- Ext InsiBedroom 3
4.1 14 0
8 0
112.0 ft'
0
0 0.6
0
10
W
Exterior
Concrete Block- Ext InsuBathroom
4.1 1 0
8 0
8.0 ft'
0
0 0.6
0
_ 11
N
Exterior
Concrete Block- Ext InsiBedroom 2
4.1 15 0
8 0
120.0 ft'
0
0 0.6
0
_ 12
E
Exterior
Concrete Block- Ext InsiBedroom 2
4.1 6 0
8 0
48.0 ft'
0
0 0.6
0
_ 13
S
Exterior
Concrete Block- Ext InstBedroom 2
4.1 1 0
8 0
8.0 ft'
0
0 0.6
0
_ 14
W
Exterior
Concrete Block- Ext InstBedroom 2
4.1 14 0
a 0
112.0 ft'
0
0 0.6
0
_ 15
N
Garage
Frame - Wood Bedroom 3
11 11
8
88.0 ft'
0
0.25 0.600000 0
_16
N
Garage
Frame -Wood Laundry
11 6
8
48.0 ft'
0
0.25 0.600000 0
17
N
Garage
Frame - Wood Bathroom
11 6
8
48.0 ft'
0
0.25 0.600000 0
DOORS
#
Omt
Door Type Space
Storms
U-Value
Width
Height
Area
Ft
In
Ft In
1
N
Wood Family Room
None
.39
3
6 10
20.5 ft'
WINDOWS
Orientation shown is the entered. Proposed orientation.
/
Wall
Overhang
V
#
Omt ID
Frame Panes NFRC
U-Factor SHGC Imp
Area
Depth
Separation
Inl Shade
Screening
1
E 1
Metal Low-E Double Yes
0.65 0.25 N
9.0 tN
1 ft 5 in
1 ft 4 in
None
None
2
N 3
Metal Low-E Double Yes
0.65 0.25 N
15.0 ft'
1 ft 5 in
1 It 4 in
None
None
_
3
E 4
Metal Low-E Double Yes
0.65 D.25 N
30.0 R'
1 It 5 in
1 ft 4 in
None
None
4
S 6
Metal Low-E Double Yes
0.65 0.25 N
9.0 ft'
1 ft 5 In
1 ft 4 in
None
None
_
5
S 7
Metal Low-E Double Yes
0.65 0.25 N
40.8 ft'
12 It 0 in
1 ft 4 in
None
None
6
N 8
Metal Low-E Double Yes
0.65 0.25 N
30.0 ft'
5 ft 0 in
1 ft 4 in
None
None
7
N 8
Metal Low-E Double Yes
0.65 0.25 N
10.2 ft'
5 ft 0 in
1 ft 4 in
None
None
8
S 9
Metal Low-E Double Yes
0.65 0.25 N
15.0 ft'
1 ft 5 in
1 ft 4 in
None
None
9
N 11
Metal Low-E Double Yes
0.65 0.25 N
15.0 ft'
1 ft 5 In
1 114 in
None
None
GARAGE
#
Floor Area Ceiling Area Exposed Wall Perimeter
Avg. Wall Height
Exposed Wall Insulation
1
484 fN 484 ft'
22 ft
8 ft
11
INFILTRATION
# Scope
Method SLA CFM 50 ELA
EgIA
ACH
ACH 50
1 Wholehouse Proposed ACH(50) .000356 1722 94.54 177.79
.2578
7
4110/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6
FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT
HEATING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Block
Ducts
1
Electric Strip Heat/
None
COP:1 27 kBtulhr
1
sys#1
COOLING SYSTEM
#
System Type
Subtype
Efficiency Capacity
Air Flow
SHR
Block
Ducts
1
Central Until
Split
SEER: 16 35.4 kBtu/hr cfm
0.7
1
sys#1.
HOT WATER SYSTEM
#
System Type SubType
Location
EF Cap Use
SetPnt
Conservation
1
Electric None
Laundry
0.95 50 gal 60.9 gal
120 deg
None
SOLAR HOT WATER SYSTEM
FSEC
Collector
Storage
Cart
# Company Name
System Model # Collector Model
# Area
Volume
FEF
None None
ft2
DUCTS
/
—Supply—
—Return Air
CFM 25
CFM25
HVAC#
V #
Location R-Value Area
Location
Area Leakage Type Handler
TOT
OUT
ON
RLF
Heat Cool
1
Attic 6 115 ft2
Hall
35 ft2 Default Leakage Laundry
(Default) (Default)
1 1
TEMPERATURES
Programable Thermostat: Y
Ceiling Fans:Cooling
Vent
Jan Feb Mar
Jan Feb
Apr
f
�X DC]
Jun [ l Jul I ] Aug
I I
�X
[ Sep
[ ]
L.l
r0('i
Dec
ng
[X� Mar
X� ApNV
r
May Jun [ Jul [ 1 Aug
[ Sep
lxl
Oct
[X] Nov
Dec
Thermostat Schedule: HERS 2006 Reference
Hours
Schedule Type
1
2 3
4 5 6 7
8
9
10
11
12
Cooling (WD)
AM 78
78 78
78 78 78 78
78
80
80
80
80
PM 80
80 78
78 78 78 78
78
78
78
78
78
Cooling (WEH)
AM 78
78 78
78 78 78 78
78
78
78
78
78
PM 78
78 78
78 78 78 78
78
78
78
78
78
Heating (WD)
AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
Heating (WEH)
AM 66
66 66
66 66 68 68
68
68
68
68
68
PM 68
68 68
68 68 68 68
68
68
68
66
66
4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6
FORM R405-2017
INPUT SUMMARY CHECKLIST REPORT
MASS
Mass Type
Area
Thickness
Furniture Fraction
Space
Default(8 lbs/sq.ft.
0 ft'
0 ft
0.3
Master Bath
Default(8 lbs/sq.ft.
ft'
ft
0.3
Master Closet
Default(8 lbs/sq.fL
W
ft
0.3
Master Bedroom
Default(8 lbs/sq.ft.
ft'
ft
0.3
Kitchen
Default(8 lbs/sq.ft.
ft'
ft
0.3
Dining
Default(8 lbs/sq.ft.
W
ft
0.3
Family Room
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bedroom 3
Default(8 lbslsq.ft.
ft'
ft
0.3
Laundry
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bathroom
Default(8 lbs/sq.ft.
ft'
ft
0.3
Bedroom 2
Default 8lbs/s .ft.
W
ft
0.3
Hall
Name: Signature:QOVlldlJ�\'/Ic Q.IdJ
Rating Compant: Date: 0-lo -lal
4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6
2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
TABLE 402.4.1.1
AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA
Project Name: Pauley Residence Builder Name:
Street: XXX Seminole Road Permit Office: St. Lucie County
City, State, Zip: Fort Pierce, FL, 34951 Permit Number:
Y
Owner. Pauley Residence Jurisdiction: St. Lucie County
w
Design Location: FL, Fort Pierce
U
COMPONENT
AIR BARRIER CRITERIA
INSULATION INSTALLATION CRITERIA
General
A continuous air barrier shall be installed in the building envelope.
Air -permeable insulation shall
requirements
The exterior thermal envelope contains a continuous air barrier,
not be used as a sealing material.
Breaks or joints in the air barrier shall be sealed.
Ceiling/attic
The air barrier in any dropped ceiling/soffit shall be aligned with
The insulation in an dropped ceiling/soffit
Y
the insulation and any gaps in the air barrier shall be sealed.
shall be aligned with the air barrier.
Access openings, drop down stairs or knee wall doors to
unconditioned attic spaces shall be sealed.
Walls
The junction of the foundation and sill plate shall be sealed.
Cavities within comers and headers of frame walls
The junction of the top plate and the top of exterior walls shall be
shall be insulated by completely filling the cavity
sealed,
with a material having a thermal resistance of R-3
Knee walls shall be sealed.
per inch minimum.
Exterior thermal envelope insulation for framed
walls shall be installed in substantial contact and
continuous alignment with the air barrier.
Windows, skylights
The space between window/doorjambs and framing, and
and doors
skylights and framing shall be sealed.
Rim joists
Rim joists shall include the air barrier.
Rim joists shall be insulated.
Floors
The air barrier shall be installed at any exposed edge of
Floor framing cavity insulation shall be installed to
(including
insulation.
maintain permanent contact with the underside of
above -garage
subfloor decking,or floor framing cavity
g insulation
and cantilevered
shall be permitted to be in contact with the top side
floors)
of sheathing, or continuous insulation installed on
the underside of floor framing and extends from the
bottom to the top of all perimeter floor framing
members.
Crawl space walls
Exposed earth in unvented crawl spaces shall be covered with
Where provided instead of floor insulation, insulation
a Class I vapor retarder with overlapping joints taped.
shall be permanently attached to the crawlspace
Shafts, penetrations
Duct shafts, utility penetrations, and flue shafts opening to
exterior or unconditioned space shall be sealed.
Batts in narrow cavities shall be curt to fit, or narrow
Narrow cavities
cavities shall be filled by insulation that on
installation readily conforms to the available cavity
spaces.
Garage separation
Air sealing shall be provided between the garage and conditioned spac
s.
Recessed lighting
Recessed light fixtures installed in the building thermal envelope
Recessed light fixtures installed in the building
shall be sealed to the drywall.
thermal envelope shall be airtight and IC rated.
Plumbing and wiring
Batt insulation shall be cut neatly to fit around wiring
and plumbing in exterior walls, or insulation that on
installation readily conforms to available space shall
Shower/tub
The air barrier installed at exterior walls adjacent to showers and
Exterior walls adjacent to showers and tubs shall
on exterior wall
tubs shall separate them from the showers and tubs.
be insulated.
Electricallphone box or
The air barrier shall be installed behind electrical or communication
exterior walls
boxes or air -sealed boxes shall be installed.
HVAC register boots
HVAC register boots that penetrate building thermal envelope shall
be sealed to the sub -floor or drywall.
Concealed
When required to be sealed, concealed fire sprinklers shall only be
J
sprinklers
sealed in a manner that Is recommended by the manufacturer.
Caulking or other adhesive sealants shall not be used to fill voids
between fireliclijoider QQY9LVjatU and Wall or cellings
I
a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400.
4/10/2019 4:30 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1
2017 EPL DISPLAY CARD
ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD
ESTIMATED ENERGY PERFORMANCE INDEX* = 92
The lower the Energy Performance Index,
the more efficient the home.
1. New home or, addition
1. New (From Plans)
12. Ducts, location & insulation level
a) Supply duds R
6.0
2. Single-family or multiple -family
2. Single-family
b) Return ducts R
6.0
c) AHU location Attic/Hall
3. No. of units (if multiple -family)
3.
1
4. Number of bedrooms
4.
3
13. Cooling system: Capacity
35.4
a) Split system SEER
16.0
5. Is this a worst case? (yes/no)
5.
No
b) Single package SEER
c) Ground/water source SEER/COP
6. Conditioned floor area (sq. ft.)
6.
1845
d) Room unit/PTAC EER
e) Other
7. Windows, type and area
a) U-factor:(weighted average)
7a.
0.650
b) Solar Heat Gain Coefficient (SHGC)
7b.
0.250
14. Heating system: Capacity
27.0
c) Area
7c.
174.0
a) Split system heat pump HSPF
b) Single package heat pump HSPF
8. Skylights
c) Electric resistance COP
1.0
a) U-factor.(weighted average)
8a.
NA
d) Gas furnace, natural gas AFUE
b) Solar Heat Gain Coefficient (SHGC)
8b.
NA
e) Gas furnace, LPG AFUE
f) Other
9. Floor type, insulation level:
a) Slab -on -grade (R-value)
9a.
0.0
b) Wood, raised (R-value)
9b.
15. Water heating system
c) Concrete, raised (R-value)
9c.
a) Electric resistance EF
0.95
b) Gas fired, natural gas EF
10. Wall type and insulation:
c) Gas fired, LPG EF
A. Exterior.
d) Solar system with tank EF
1. Wood frame (Insulation R-value)
10A1.
e) Dedicated heat pump with tank EF_
2. Masonry (Insulation R-value)
10A2.
4.1
0 Heat recovery unit HeatRec%
B. Adjacent:
g) Other
1. Wood frame (Insulation R-value)
1081.
11.0
2. Masonry (Insulation R-value)
10132.
16. HVAC credits claimed (Performance Method)
11. Ceiling type and insulation level
a) Ceiling fans
Yes
a) Under attic
11a.
38.0
b) Cross ventilation
No
b) Single assembly
11b,
c) Whole house fan
No
c) Knee walls/skylight walls
11c.
d) Multizone cooling credit
d) Radiant barrier installed
11d.
No
e) Multizone heating credit
0 Programmable thermostat
Yes
*Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT.
I certify that this home has comp the Florida Building Code, Energy Conservation, through the above energy
saving features which will be i to% led (or exceeded) in this home before final inspection.7th8ise, a new EPL
display card will be complete b 5ed on i stall d code compliant features.
Builder Signature: ✓� Date:
Address of New Home: XXX Seminole Road City/FL Zip: Fort Pierce, FL 34951
411012019 4:30:08 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1
-F- wrightsoftProject Summary
Entire House
Quick Calcs, Inc.
317 St. Lucie Lane, Fart Pierce, FL 34946 Phone: 7724666799 avail: quickcal
For:
Notes:
SCANNEDFILE COPY.oat:
BN
Pauley Residence
XXX Seminole Road, Fort Pierce, FL 34951
APR 17 niq
ST_Lucie county, pernt
Design
Information
Weather:
Fort Pierce, FL, US
Winter Design Conditions
Summer Design Conditions
Outside db 42 OF
Outside db
90
OF
Inside db 70 OF
Inside db
75
OF
Design TD 28 OF
Design TD
15
OF
Daily range
M
Relative humidity
50
%
Moisture difference
61
grAb
Heating Summary
Structure
18516
Stun
Duds
5683
Stun
Central vent (0 cfm)
0
Stuh
(none)
Humidification
0
Btuh
Piping
0
Btuh
Equipment load
24199
Btuh
Infiltration
Method
Construction quality
Fireplaces
Simplified
Average
0
Heat'
t845 C00 J
Area (ft�
Volume (it)
14760 14760
Air changes/hour
0.38 0.20
Equiv. AVF (cfm)
93 49
Heating Equipment Summary
Make
Trade
Model
AHRI ref
Efficiency
Heating input
Heating output
Temperature rise
Actual air flow
Air flow factor
Static pressure
Space thermostat
100 EFF
6.6 kW
22524 Btuh
17 OF
1180 cfm
0.049 cfm/Btuh
0.50 in H2O
Sensible Cooling Equipment Load Sizing
Structure
17343
Stun
Duds
8147
Btuh
Central vent (0 cfm)
0
Stun
(none)
Blower
0
Btuh
Use manufacturer's data n
Rate/swing multiplier 0.95
Equipment sensible load 24216 Btuh
Latent Cooling Equipment Load Sizing
Structure
4255
Stun
Ducts
2220
Stun
Central vent (0 cfm) .
0
Stun
(none)
Equipment latent load
6476
Btuh
Equipment Total Load (Sen+Lat)
30692
Btuh
Req. total capacity at 0.70 SHR
2.9
ton
Cooling Equipment
Summary
Make Rheem
Trade RHEEM
Cond RA1636AJlNB
Coil RH1T3617STANAA
AHRI ref 7942207
Efficiency 13.0 EER, 16 SEER
Sensible cooling
24780
Btuh
Latent cooling
10620
Stun
Total cooling
35400
Btuh
Actual air flow
1180
cfm
Air flow factor
0.046
cfm/Btuh
Static pressure
0.50
in H2O
Load sensible heat ratio
0.80
Calculations approved by ACCA to meet all requirements of Manual J 8th Ed.
_ wrightzsoft' 2019-Apr-1016.26:29
1 Right -Suite® universal 201919.0.01 RSUD8101 Pagel
ACCk .-TowmeWWrightsoft HVACtPauley resieence.rup Calc=MJ8 Front Door faces: N
wrightsoft• Right-J® Worksheet Job:
Enure House Date:
Quick Calcs, Inc. By.
317 St. Lude Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcslcs@aol.wrn
1
2
3
4
Room name
Exposed wall
Room height
Room dimensions
Room area
Entire House
174.0 R
8.0 R
1845.0 fl2
Master Bath
24.0 R
8.0 R heaticeol
14.0 x 10.0 it5
140.0 ft'
Ty
Construction
number
U-valu
{Btuh/ftZ-FJ�
Or
HTM
I (Bluh/ftq
Area (ft')
I- or perimeter (R)
Load
I (Btuh) I
Area _(fl')
or perimeter (R) I
Load
(BNh)
Heat
Cool
Gross
I WP/S
Heal
I Cool
Gross
I WP/S
Heat
I Cool
8
11
�13A-4ecs. �'
4AS2em'
4AS2em
4A5-2orn
_11D0_�-.,
laA,.,�_
4A5-2em
4A -Zom
13A40es
10D-m- -
4A5.2om
4A5,2om_.___,
13A4ocs
0.t43
0.770
0.770
0.770
�-0.390
0.143
0.770
0.770
0.143
1.380
-0.770
-__0.770
0.143
n
n
n
n
-n-
a
a
_ e
a
s
s
_a_
w
4.00
21.56
21.56
21.56
_._10.92
4.00
21.56
21.56
4.00
38.92
21.56
_21.56,
4.00
2.19
19.31
19.31
19.31
-10.34
2.19
47.10
47.10
2.19
20.03
19.31
-19.31.
2.19
. 440
30
30
10
___20
344
9
30
_ 0
44
41
9
75
168
_
- 349
0
0
0
___,20
305
0
_ 0
�375
41
9
75
168
1399
647
647
220
__---223
1221
194
647
1502
1588
194
323
673
_
�784
579
579
197
--211
667
424
1413
821
817
174
__290
368
__
A
0
0
0
-.__--0
8o
9
0
-� 0
0
0
0
.___ „0
71
0
0
-_�-0---
0
0
0
,�___-0
284
194
0
-0
0
0
0
,-__... -0
155
424
0
_ _
G
_
y 112
0
0
__0
0
_
112
0
0
___0
0
---� 448
0
0
__._--- 0
0
_ _
245
0
0
.____0
0
W
C.�=
F
]BBE388tl �_
22A-Ipl
-__0.026
0.989
_
�__0.73.
27.69
� 1.30
0.00
,-1845
1045
_ 1845
174
_1343
4818
_
�_-_2399
0
_
__740
140
_._-140
24
-- _702
665
^.. _. 10
0
61
c) ASO excursion
0
30
Envelope losa/gain
15639
9702
1693
t037
12
a) Infiltration
b) Roonlventilation
2877
0
811
0
397
0
112
0
13
Internal gains: Occupants@ 230
Appllances'other
11
2530
430
0
1
0
0
Subtotal Qines 6 to 13)
1 18516
17343
1
2090
1148
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duct leads
31%
47%
0
0
0
18518
5683
0
0
0
17343
8147
31%
47%
0
0
0
2090
641
0
0
0
1148
539
TotsAir re redl(1
I
I
277 01
2118
I
1
1 21331
7fi781
Calculations approved by ACCA to meet all requirements of Manual J Sth Ed
�I} wra9heso,� 2019-Apr-1016:26:29
Right-Suitelece.rup Calee1919.0.ro RSUr face Pagel
...\Documents\WrighLsoR HVAC1Pauley residence.rup CaIc=MJB Front Door faces: N
wrightsoft Right-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.00m
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Master Closet
0 8
8.0 0 heat/cool
10.0 x 8.0 8
80.0 fl'
Master Bedroom
47.0 0
8.0 8 heat/cool
1.0 x 298.0 it
298.0 fl'
Ty
Construction
number
ll-value j
(Btuh/ft;°F
Or
I HTM
(Btuh/ft')
I Area (ft')
or perimeter (8)
I Load I
(Btuh)
Area (W) I
or perimeter (fi)
Load
(Bluh)
Heal
Cool
rG.Sa
N/P/S
Heat
Cool
Gross
WP/S
Heat
Cool
B
17
13A-0oce
4A5-2om
4A5-2om
4AS-20M
11D0-_,-
13A-4ocs
4A5-2om
4A8-2om
0143
0770
0770
0770
- -0.390
0.143
0.770
0.770
n
n
n
n
_:n_
a
a
a
-- 400
2156
2156
2156
_10.92
4.00
21.56
21.56
2.19
19.31
19.31
19.31
._70.34
'----0
- 0
0
0
-0
�_-0
0
0
0
-.___0
_ _ 0
0
0
0
---0
0
0
0
� 0
0
0
0
--._0
_
712
15
0
.0
.__0
'- 97
0
0
0
___0---
-' 388
323
0
0
_0
745
0
647
�212
290
0
0
-----0
407
0
1413
W
L�-GG
2.19
47.10
47.10
0
0
0
0
0
0
0
0
0
215
0
30
186
0
0
-
W
.C_-_..18&38aC-'-:
F
13A4ocs
70D-m
4A5-2om
4A52om
13A-0nce
22A-tpl
'-- 0.143
1.390
0.770
�.0.770
0,143
w_0.026
0.989
s
a
s
-a_
w
4.00
38.92
21.56
_.21.56,
2. 99
20.03
19.31
_19.31
_ _
�- 0
0
0
__ 0
� 0
0
0
,_,__0
_
'0
0
'0
_._0
0
0
0
__0
__
0
0
0
__0
0
0
0
0
48
_,._.298
47
0
0
0-
___O
192
_--_217
1302
0
0
0
v- _0
105
_.y- 387.
0
4.00
..`_0.73.
27.69
2.19
__1.30
0.00
0
-_80
80
0
__--:80
0
0
_. _58
0
_ 0
.:104
0
48
__298
298
8
c)AED excursion
0
-8
Envelope loss/gain
58
104
3814
28;
12
a) Infiltration
b) Room ventilation
0
0
0
777
0
219
0
13
Internal gains: Occupants@ 230
Appliances/omer
0
0
0
2
"0
900
Subtotal (lines 6 to 13)
1 58
104
1
1 4591
4385
14
15
Less external lead
Less transfer
Redisbibution
Subtotal
Ductleads
31%
47%
0
0
0
58
18
0
0
0
104
49
31%
47%
0
0
0
4591
1409
0
0
0
4385
2060
A!rrequlet reNdl(cfm)
I
I
I 741
157I
I
I 6293I 110
6288I
Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed.
- =':L ^o� 2019-Apr-1016:26:29
Right -Suite® U niversal 201919.0.01 RSU08101 Paget
...TocumentslWrightsoft HVACTauley resieence.rup Calc=MJ8 Front Dow faces: N
wrightsoft• Right -JCS Worksheet Job:
Entire House Date.
Quick Calcs, Inc. By.
317 St. Lucie Lane, Fart Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Roam height
Room dimensions
Room area
Kitchen
14.0 R
8.0 R heall000l
14.0 x 18.0 It
252.0 fl'
Dining
12.0 It
8.0 It heaycool
12.0 x 18.0 R
216.0 ft'
Ty
Construction
number
U-value
(Stuhlftk'F
Or
KM
(Btuhffl')
Area (f")
I or perimeter (R) I
Load
(Btuh) I
Area (fl')
or perimeter (ft) _I
Load
(BNh)
Heat
Coal
Gross
NINS
Heat
Cool
Gross
N/P/S
Heat
Cool
6
11
-�O.a_
0
0
0
__0
0
0
0
0
0
0
0
_0
0
0
0
U
0
0
0
__- _.0
0
0
0
_ �O
0
0
0
___.0
0
0
0
0
0
0
0
___0
0
0
0
____. 0
0
0
0
__0
0
0
0
0
0
0
0
_.__,0
0
0
0
-_�.. 0
0
0
0
�:------- 0
0
0
0
--
Y3A-4ocs.
4A5-2om
4A5-2mn
4A5-tom"
.11D0-_____
13A.40 a
4AS-2om
4AS2om �-
0143
0770
0770
0770
..__..__0,390
0.143
0.770
0.770
n
n
n'
n
_n-
a
a
e_
400
2156
2156
21M
-1092
4.00
2156
2156
2.19
19.31
19.31
19.31
-10.34
2.19
47.10
47.10
_
W
�G
�G
_
W
-C__.._
F _
13A-flocs-
4OD-m
4A5-2om -
4A5-20m_.-
13A4ocs
0143
- 1390
0770
-...,_.0770
0.143
's
s
s
-s_.
w
--400
38.92
21.56
_21.56
4.00
2.19
20.03
19.31
,_19.31
2.19
112
0
9
_-_.__0
0
_
103
0
9
----0
0
.252
14
412
0
194
_______0
0
183
388
_
225
0
174
-_._0
0
.___328
0
96
41
0
---- -0
0
'65
41
'0
_-_0
0
_
221
- 1588
0
___0
121
817
0
_.,.__. 0
0
-___ 281.
0
0
,16&'38ed _-
PLO!_
-_0.026
0.989
l=
�_
_ _0.73
_ _1.30
2.00
^252
252
__218
_ _. 216
__216
12
_
___157.
_ _-_ 332
_27.69
-
61
0) AED excursion
Envelope losstgain
1 1178
721
2299
1215
12
a) Infiltration
b) Room ventilation
231
0
65
0
1
198
1 0
56
0
13
Internal gains: Occupants@ 230
Appliancestother
2
460
2000
2
460
0
Subtotal (lines 6 to 13)
1 1409
3248
1
1 2497
1731
14
15
Less external load
Less transfer
Redistibution
Subtotal
Duct loads
31%
47%
0
0
0
1409
432
0
0
0
3248
1525
31%
47%
0
0
8
2505
769
0
0
14
1745
820
TotaAir regred(.b
I
I
I 1 90I
4221I
I
I 3160I
2179
Calculations approved by ACCA to meet all requirements of Manual J Sth Ed
-1- 2019-Apr.1016:26:29
. A Right -Suite® Universal 201919.0.01 RSU08101 Page
...1Documents\Wdghtsoft HVACIPauley residence.rup rate =MJ8 Front Door faces: N
wrightsoft' Righter Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St. Lude Lane, Fort Pierce, FL 34946 Phone: T72-466-6799 Email: quiokcelcs@)aoLwnn
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Family Room
26.0 ft
8.0 ft heaVwol
28.0 x 13.0 8
338.0 f['
BW=m 3
14.0 ft
8.0 ft heallcool
14.0 x 11.0 ft
154.0 ft'
Ty
ConsWct=
number -
U-value
{Btuh/tK°F
Or
j M
(Btuh/ft')
Area (ft2)
I- or penmstar (ft)
Load
I (Stub
Area (ft')
I or perimeter (ft)
Load
I (Brun)
Heat
I Cool
Gross
I N/P/S
I Heal I
Cool
Gross
I N)P)S
Heat
Cool
6
11
_
73A-flocs
4A5-2om
4AS2om
4AS26m
AIDO
13A-floes
4AS2om
4AS2om
^ 0143
__ 0770
0770
0770
-0.390
0.143
0.770
0.770
n
h
a
n
.._n_
a
a
e_
400
2156
2156
2156
-1092
4.00
21.56
21.56
2.19
19.31
19.31
19.31
__10.34
2.19
47.10
47.10
--208
0
30
10
-20
0
0
0
147
0
0
0
`.20
0
0
0
590
0
647
220
223
0
0
0
322
0
579
197
_ __211
0
0
0
-0
0
0
0
_-0
0
0
0
~0
0
0
' 0
-___0
0
0
0
-0
0
0
0
- ---0
0
0
0
0
0
0
'0
�._.._. 0
0
0
0
Yy
��__GG
13A-4ba '--
1OD-rn _
4AS2om
AA5r20m_..
13A-4ocs
0.143
1.390
0.770
...,._0.770
0.143
s
s
s
,.ems_
w
4.00
38.92
21.56
_. 21.56
4.00
2.19
20.03
19.31
__.19.31
2.19
0
0
0
.V__.0
0
-- _ 0
0
0
._0
0
' 0
0
0
__..._0
0
0
0
0
,_. _O
0
112
0
0
__._15
0
97
0
0
�- 388
0
0
___ _323,
0
1-212
0
0
�.290
0
-
W
_.�75
0
C... �,
F _
.i6B38a'd
22A-Ipl
=W0.026
=_0.73..�1.30
=---338
_ 338
26
�. 446---430
720
-154
164
=11,12
... 200
0
0989
27.69
0.00
_ 338
0
164
_,14
_ 388
61
c) AED excursion
Envelope lesslgain
2648
1743
1212
700
12
a) Infiltration
b) Room ventilation
430
0
121
0
231
0
65
0
13
Internal gains: Occupants @j 230
Appliances/other
2
460
900
1
230
0
Subtotal (lines 6 to 13)
3076
3224
1443
995
14
15
Less external load
Less transfer
Redistribution
Subtotal
Dud loads
31%
47%
0
0
5
3081
946
0
0
70
3234
1519
31%
47%
0
0
4
1447
444
0
0
8
1003
471
LI
quired Air re(cfm)
I
I
I 4098I
4�9I
I
I 18992I
1468
Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed
=Iatrs soft- 2019-Apr-1016:26:29
Right -Suite® Universal 201919.0.01 RSU08101 Page
...100cuments\Wrightsofl WACIPauley residence.rup Cale=M,18 Front Door faces: N
wrightsoft• Right-M Worksheet Job:
Entire House Date:
Quick Calcs, Inc. By.
317 St. Lucie Lane, Fort Pierce, FL 34W Phone: 772466-6799 Email: quickmlcs@aol.com
1
2
3
4
5
Room name
Exposed wall
Room height
Room dimensions
Room area
Laundry
0 ft
8.0 ft heat(cool
10.0 x 6.0 ft
60.0 ft'
Bathroom
1.0 ft
&0 ft heaVwol
10.0 x &0 ft
60.0 ft2
Ty
construction
number
U-value
(BIuiVfR°F
j Or
HiM
I (Bluhf t=
Area (ft2)
I or perimeter (ft)
Load
I (Btuh)
Area (fP)
I or perimeter (ft)
Load
I (Btuh)
Heat
Cool
Gross
WP/5
Heat
Cool
Gross
WP/S
Heat
Cool
1
T-
6
17
ll�--ODD
13A-4acs
4A5-tom
4A5-2orn _
4A5-tom
11D0
13A.4ocs
4AS-2om
4Ai2om
- 0143
0770
0770
0770
-0.390
0.143
0.770
0770
n
n
n
n
-n_
a
a
_e
� 400
2156
2156
_ �21.58
--10.92
4.00
21.56
2156
2.19
19.31
19.31
19.31
_10.34
2.19
47.10
47.10
0
0
0
-- 0-
_0
0
0
0
_ 0
0
- 0
0
•0
0
0
0
--0
01
.0
0
__.__-0�0
0
0
0
-0
0
0
0
0
0
0
0'
00
0
0
0
0
,0
0
0�
0.
0 -0
'0
0
-0
-0
VIA
�f
�G
0
0
0
0
0
0
0
0
--a
0
0
0
0
0
0
13A-0ad. aF'-
10D-m _ _
4A5-2om '_
4AS20m
13A-4ocs
- 0143
1390
'0770
--0.7,70
0.143
s-.
5
s.
._s„
w
400
3892
. _2156
-.21.56
4.00
fl9
20.03
19.31
-19.31,
2.19
_
' 0
0
0
- 0
0
0
.0
____0
0
- 0
0
r,.__0
0
0
0
0
_0
0
_ 0
- 0.
'0
0
0
0
_ -0
-� 0
_ '0
^ 0
..,_.� -0
_
� 0
0
0
-,._-0
�G
L-G
W
0
0
0
0
8
8
32
18
F
-16B;38adL._..;.�.:_
22A-tpI __-�_
,:.0. 226
�- 0.989
-
-
cs073
27.69
. _7.30
0R00
____e_60
fi0
= 60
0
._.._44
0
,. -„ .78
0
_=60
80
=60
1
_�- _44
28
78
0
`.
6
c) AED excursion
_7
0
Envelope loss/gain
44
77
703
95
72
a) Infiltration
b) Room ventilation
0
0
0
0
17
0
5
0
13
Internal gains: Occupants @ 230
Applianceslother
0
0
500
0
0
0
Subtotal (lines 6 to 13)
44
577
120
100
14
15
Less external load
Less transfer
Redistribution
Subtotal
Duo loads
31%
47%
0
0
7
50
15
0
0
12
589
276
31%
47%
0
0
7
126
39
0
0
12
112
52
m load
Nr acquired(dra) I
I
I
6840I
63I
I
I
1681
1 8I
Calculations awroved by ACCA to meet all reauirements of Manual J 8th Ed
-�Mff co>�C- 2019-Apr-1016:26:29
Right -Suite® Universal 201919.0.01 RSU08101 Page
...1DocumentsWightsoft HVACIPauley residence.mp Cale =MJB Front Door faces: N
Zo
NA
m
N
m
H
5.
v a
T
m
m
6 3a
g
v°
$-c3
c
I
�
I
+
!o:o�loop�000��
Tm
impip
i!
��
Il
i► °
{iv!{8!
_
o
�°
Ci
Ii►
i�
�!
f� 4�
I ��
f�
i
i�
gi
gI, �s
f11�
I
fl
�I
}1
�1
it
,1
I
11
I
�l
O, INbb ON
JJN Om bb N
J
m
-
��
{I
�
l{
II
1, I,
{a
11
{1►{o�m„�,
biOOm
b
1111I!II!I
1j1j
111d
m
N
i
f
1
9
C
i I
I{
. I i
II
mb
_
NOOOm
pI
OO OOONOI
m
a
3^
b
O O
I
I
b N
1
(
I
I
f�
F�
� �
1
! �Im
Ala• m
b NN
W�
p
iJ
O0AOO
fNil
Olbll
0
}I II
{ I{
f1
II
II
�! I
I'
1 I
I
JN m�O O'O N!OON
OO O(J OI
ObNOOOm
OOm OOOOOI
!
r
+
`s
I
I
I � +mm
000 oo
0000000'0l
3,�
o c
A
0
I
Om•OOO
OOIOOO
OO OOO
_
+
I { i';
!
I
i t
+
to Nl000
ooi000
oo 000,
m
m
I
00
OONOO
N
00
00
N
O
I I I
I•
11 �
�
I I I 1 j •
I I I��
.
l
I{
g.l ! '
} I � m�,
` I ON•OOO OO1OOO
OO'OOO�
—
Duct S stem Summa Job:
wrightsoft° y � Date:
Entire House By:
Quick Calcs, Inc.
317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs®aol.com
Project• •
For: Pauley Residence
XXX Seminole Road, Fort Pierce, FL 34951
External static pressure
Pressure losses
Available static pressure
Supply / return available pressure
Lowest friction rate
Actual air flow
Total effective length (TEL)
Heating
0.50
in H2O
0
in H2O
0.50
in H2O
0.250 / 0.250
in H2O
0.356
in/100ft
1180
cfm
141 ft
Cooling
0.50 in H2O
0 in H2O
0.50 in H2O
0.250 / 0.250 in H2O
0.356 in/100ft
1180 dm
Supply Branch Detail Table
Name
Design
(Btuh)
Htg
(dm)
Clg
(dm)
Design
FIR
Diam
(in)
H x W
(in)
Dud
Matl
Actual
Ln (ft)
Ftg.Egv
Ln (ft)
Trunk
Bathroom
h 165
8
8
0.501
4.0
Ox0
VIFx
9.9
90.0
st1
Bedroom
h 4127
201
121
0.472
8.0
Ox0
VIFx
16.0
90.0
SO
Bedroom
h 1892
92
68
0.501
7.0
OXO
VIFx
9.9
90.0
st1
Dining
h 3273
160
119
0.449
8.0
Ox 0
VIFx
21.2
90.0
st3
Family Room
c 2376
98
110
0.356
7.0
OXO
VIFx
30.6
110.0
st4
Family Room -A
c 2376
98
110
0.360
7.0
OXO
VIFx
29.0
110.0
st4
Kitchen
c 2385
45
110
0.431
7.0
Ox0
VIFx
26.1
90.0
st3
Ktchen-A
c 2385
45
110
0.442
7.0
Ox0
VIFx
23.0
90.0
st3
Laundry
c 865
3
40
0.516
5.0
Ox0
VIFx
6.8
90.0
SO
Master Bath
h 2732
133
78
0.364
7.0
Ox0
VIFx
47.4
90.0
st2
Master Bedroom
c 3223
146
149
0.371
7.0
Ox0
VIFx
44.8
90.0
st2
Master Bedroom -A
c 3223
146
149
0.386
7.0
Ox0
VIFx
39.4
90.0
st2
Master Closet
c 153
4
7
0.386
4.0
Ox0
VIFX
39.6
90.0
st2
Supply Trunk Detail Table
Trunk
Htg
Clg
Design
Veloc
Diam
H x W
Duct
Name
Type
(dm)
(dm)
FR
(fpm)
(in)
(in)
Material
Trunk
st2
Peak AVF
430
384
0.364
547
12.0
0 x 0
VinlFlx
st4
Peak AVF
196
220
0.356
498
9.0
0 x 0
VinlFlx
st3
st3
Peak AVF
446
560
0.356
523
14.0
0 x 0
VinlFlx
st1
Peak AVF
305
237
0.472
559
10.0
0 x 0
VinlFlx
-Ok wrightsoft- 2019-Apr-1016:26:29
^•� •-•-• ..�...-. RighlSuite® Universal 201919.0.01 RSU08101 Pagel
/ .G1 ...1D1wmen1%1Wnghteoft HVACTauley residence.mp Gale =MJ8 Front Door faces: N
Return Branch Detail Table
Name
Grille
Size (in)
Htg
(dm)
Clg
(dm)
TEL
(it)
Design
FIR
Veloc
Opm)
Diam
(in)
H x W
(in)
Stud/Joist
Opening (in)
Duct
Matl
Trunk
rb1
Ox0
1180
1180
0
0
0
0
Ox 0
1
VIFx
wrightsoft• 2019-Apr-1016:26:29
.-. �..._. Right-Suite®Universal201919.0.01 RSU08101 Paget
+Cp... l0ooumentsXMghtsofl HVACWauleyresideoae.rup Cale=MJ8 Front Doorfaces:N