Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FILE `i 9 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business-m Pr$fs - egulation - Residential Performance Method Project Name: Pauley Residence APR 17 2019 B ilder Name: SCANNED Street: XXX Seminole Road P rtnit office: St. Lucie County City, Slate, Zip: Fort Pierce, FL, 34951 P rmit Number: BY Owner: Pauley Residence S_T. Lucie County, Permitting sdiction: St Lucie County St. Lucie County Design Location: FL, Fort Pierce County: St. Lucie (Florida Climate Zone 2 ) 1. New construction or existing New (From Plans) 9. Wall Types (1576.0 soft.) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - Ext Insul, Exterior R=4.1 1392.00 ft' b. Frame - Wood, Adjacent R=11.0 184.00 ft2 3. Number of units, if multiple family 1 c. N/A R= ft2 4. Number of Bedrooms 3 d. N/A R= ft. S. Is this a worst case? No 10. Ceiling Types (1845.0 sqft.) Insulation Area a. Under Attic (Vented) R=38.0 1845.00 ft2 6. Conditioned floor area above grade (ft� 1845 b. N/A R= ft2 Conditioned floor area below grade (ft2) 0 c. N/A R= ft2 11. Ducts R 112 7. Windows(174.0 soft.) Description Area a. Sup: Attic, Ret: Hall, AH: Laundry 6 115 a. U-Factor: Dbl, U=0.65 174.00 ft2 SHGC: SHGC=0.25 b;. U-Factor: N/A ft2 12. Cooling systems kBtu/hr Efficiency :'' SHGC: a. Central Unit 35.4 SEER:16.00 c. U-Factor: N/A ft2 SHGC: 13. Heating systems kBtu/hr Efficiency d. U-Factor. N/A ft2 a. Electric Strip Heat 27.0 COP:1.00 SHGC: Area Weighted Average Overhang Depth: 4.726 ft. Area Weighted Average SHGC: 0.250 14. Hot water systems 8. Floor Types (1845.0 sgft.) Insulation Area a. Electric Cap: 50 gallons a. Slab -On -Grade Edge Insulation R=0.0 1845.00 ft2 b. Conservation features EF: 0.950 b. N/A R= ft2 None c. NIA R= ft2 15. Credits CF, Patel Glass/Floor Area: 0.094 Total Proposed Modified Loads: 53.34 PASS Total Baseline Loads: 58.07 I hereby certify that the plans and specifications covered by Review of the plans and STg7F this calculation are in compliance with the Florida Energy specifications covered by this �FRIiE �y 0 Code. calculation indirates compliance ' with the Florida Energy Code. PREPAR BX �' Before construction is completed uP1 eb DATE: this building will be inspected for compliance with Section 553.908 I hereby certify that this building desi ed, ' in compliance Florida Statutes. with the Florida Energy Code. CAD W6 OWNER/AGENT: BUILDING OFFICIAL: DATE: DATE: - Compliance requires certification by the air handler unit manufacturer that the air handler enclosure qualifies as )certified factory -sealed in accordance with R403.3.2.1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1.1 and this project requires an .+:nvelope leakage test report with envelope leakage no greater than 7.00 ACH60 (R402.4.1.2). 4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 1 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Title: Pauley Residence Bedrooms: 3 Address Type: Street Address Building Type: User Conditioned Area: 1845 Lot # Owner Name: Pauley Residence Total Stories: 1 Block/Subdivision: # of Units: 1 Worst Case: No PlatBook: Builder Name: Rotate Angle: 0 Street: XXX Seminole Road Permit Office: St. Lucie County Cross Ventilation: No County: St. Lucie Jurisdiction: St. Lucie County Whole House Fan: No City, State, Zip: Fort Pierce , Family Type: Single-family FL, 34951 New/Ebsting: New (From Plans) Comment: CLIMATE / Design Temp Int Design Temp Heating Design Daily Temp V Design Location TMY Site 97.5 % 2.5 % Winter Summer Degree Days Moisture Range FL, Fort Pierce FL VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 Entire House 1845 14760 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 Master Bath 140 1120 No 0 1 Yes Yes Yes 2 Master Closet 80 640 No 0 1 No Yes Yes 3 Master Bedroom 298 2384 No 2 1 1 Yes Yes Yes 4 Kitchen 252 2016 Yes 2 1 Yes Yes Yes 5 Dining 216 1728 No 2 1 Yes Yes Yes 6 Family Room 338 2704 No 2 1 Yes Yes Yes 7 Bedroom 3 154 1232 No 1 1 1 Yes Yes Yes 8 Laundry 60 480 No 0 1 No Yes Yes 9 Bathroom 60 480 No 0 1 Yes Yes Yes 10 Bedroom 2 199 1592 No 1 1 1 Yes Yes Yes 11 Hall 48 384 No 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio Master Bath 24 It 0 140 ft' _ 1 0 0 2 Slab -On -Grade Edge Insulatio Master Closet 1 ft 0 80 ft' _ 1 0 0 3 Slab -On -Grade Edge Insulatio Master Bedroom 47 ft 0 298 ft' _ 1 0 0 4 Slab -On -Grade Edge Insulatio Kitchen 14 ft 0 252 ft' _ 1 0 0 5 Slab -On -Grade Edge Insulatio Dining 12 ft 0 216 ft' — 1 0 0 6 Slab -On -Grade Edge Insulatio Family Room 26 ft 0 338 ft' _ 1 0 0 4/10/2019 4:29 PM EnergyGaugeO USA Section R405.4.1 Compliant Software Page 2 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 7 Slab -On -Grade Edge Insulatio Bedroom 3 14 ft 0 164 ft2 _ 1 0 0 8 Slab -On -Grade Edge Insulago Laundry 1 ft 0 60 ft2 - 1 0 0 9 Slab -On -Grade Edge Insulago Bathroom 1 ft 0 60 ft2 _ 1 0 0 10SIab-On-Grade Edge Insulato Bedroom 2 36 ft 0 199 ft' - 1 0 0 11SIab-On-Grade Edge Insulatto Hall 1 ft 0 48 ft' - 1 0 0 ROOF / Roof Gable Roof Solar SA Emitt Emift Deck Pitch V # Type Materials Area Area Color Absor. Tested Tested Insul. (deg) 1 Hip Composition shingles 2063 ft2 0 ft2 Medium 0.6 No 0.9 No 0 26.6 ATTIC / V # Type Ventilation Vent Ratio (1 In) Area RBS IRCC 1 Full attic Vented 150 1845 ft2 N N CEILING # Ceiling Type Space R-Value Ins Type Area Framing Frac Truss Type 1 Under Attic (Vented) Master Bath 38 Batt 140 ft' 0.1 Wood _ 2 Under Attic (Vented) Master Closet 38 Batt 80 ft2 0.1 Wood _ 3 Under Attic (Vented) Master Bedroom 38 Batt 298 ft2 0.1 Wood _ 4 Under Attic (Vented) Kitchen 38 Batt 252 ft2 0.1 Wood 5 Under Attic (Vented) Dining 38 Batt 216 ft2 0.1 Wood 6 Under Attic (Vented) Family Room 38 Batt 338 ft2 0.1 Wood _ 7 Under Attic (Vented) Bedroom 3 38 Batt 154 ft2 0.1 Wood 8 Under Attic (Vented) Laundry 38 Batt 60 ft2 0.1 Wood _ 9 Under Attic (Vented) Bathroom 38 Batt 60 ft2 0.1 Wood 10 Under Attic (Vented) Bedroom 2 38 Batt 199 ft' 0.1 Wood 11 Under Attic (Vented) Hall 38 Batt 48 ft2 0.1 Wood WALLS Adjacent Cavity Width Space Height Sheathing Framing Solar Below _ 1 E Exterior Concrete Block- Ext InsMaster Bath 4.1 10 0 8 0 80.0 ft2 0 0 0.6 0 _ 2 S Exterior Concrete Block- Ext InsMaster Bath 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 _ 3 N Exterior Concrete Block- Ext ln3d6ster Bedro 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 _ 4 E Exterior Concrete Block - Ext InSdhster Bedro 4.1 27 0 8 0 216.0 ft2 0 0 0.6 0 5 W Exterior Concrete Block - Ext InMaster Bedro 4.1 6 0 8 0 48.0 ft2 0 0 0.6 0 _ 6 S Exterior Concrete Block- Ext Insul Kitchen 4.1 14 0 8 0 112.0 ft2 0 0 0.6 0 -7 S Exterior Concrete Block- Ext Insul Dining 4.1 12 0 8 0 96.0 ft2 0 0 0.6 0 8 N Exterior Concrete Block- Ext InSf9mily Room 4.1 26 0 8 0 208.0 ft' 0 0 0.6 0 4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 3 of 6 • - - I010-1 M1111fi I ill V X943.I X03I.W11i i 74lS-laIII WALLS Adjacent Space Cavity Width Height Sheathing Framing Solar Below _ 9 S Exterior Concrete Block- Ext InsiBedroom 3 4.1 14 0 8 0 112.0 ft' 0 0 0.6 0 10 W Exterior Concrete Block- Ext InsuBathroom 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 _ 11 N Exterior Concrete Block- Ext InsiBedroom 2 4.1 15 0 8 0 120.0 ft' 0 0 0.6 0 _ 12 E Exterior Concrete Block- Ext InsiBedroom 2 4.1 6 0 8 0 48.0 ft' 0 0 0.6 0 _ 13 S Exterior Concrete Block- Ext InstBedroom 2 4.1 1 0 8 0 8.0 ft' 0 0 0.6 0 _ 14 W Exterior Concrete Block- Ext InstBedroom 2 4.1 14 0 a 0 112.0 ft' 0 0 0.6 0 _ 15 N Garage Frame - Wood Bedroom 3 11 11 8 88.0 ft' 0 0.25 0.600000 0 _16 N Garage Frame -Wood Laundry 11 6 8 48.0 ft' 0 0.25 0.600000 0 17 N Garage Frame - Wood Bathroom 11 6 8 48.0 ft' 0 0.25 0.600000 0 DOORS # Omt Door Type Space Storms U-Value Width Height Area Ft In Ft In 1 N Wood Family Room None .39 3 6 10 20.5 ft' WINDOWS Orientation shown is the entered. Proposed orientation. / Wall Overhang V # Omt ID Frame Panes NFRC U-Factor SHGC Imp Area Depth Separation Inl Shade Screening 1 E 1 Metal Low-E Double Yes 0.65 0.25 N 9.0 tN 1 ft 5 in 1 ft 4 in None None 2 N 3 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 1 ft 5 in 1 It 4 in None None _ 3 E 4 Metal Low-E Double Yes 0.65 D.25 N 30.0 R' 1 It 5 in 1 ft 4 in None None 4 S 6 Metal Low-E Double Yes 0.65 0.25 N 9.0 ft' 1 ft 5 In 1 ft 4 in None None _ 5 S 7 Metal Low-E Double Yes 0.65 0.25 N 40.8 ft' 12 It 0 in 1 ft 4 in None None 6 N 8 Metal Low-E Double Yes 0.65 0.25 N 30.0 ft' 5 ft 0 in 1 ft 4 in None None 7 N 8 Metal Low-E Double Yes 0.65 0.25 N 10.2 ft' 5 ft 0 in 1 ft 4 in None None 8 S 9 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 1 ft 5 in 1 ft 4 in None None 9 N 11 Metal Low-E Double Yes 0.65 0.25 N 15.0 ft' 1 ft 5 In 1 114 in None None GARAGE # Floor Area Ceiling Area Exposed Wall Perimeter Avg. Wall Height Exposed Wall Insulation 1 484 fN 484 ft' 22 ft 8 ft 11 INFILTRATION # Scope Method SLA CFM 50 ELA EgIA ACH ACH 50 1 Wholehouse Proposed ACH(50) .000356 1722 94.54 177.79 .2578 7 4110/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 4 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT HEATING SYSTEM # System Type Subtype Efficiency Capacity Block Ducts 1 Electric Strip Heat/ None COP:1 27 kBtulhr 1 sys#1 COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts 1 Central Until Split SEER: 16 35.4 kBtu/hr cfm 0.7 1 sys#1. HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Laundry 0.95 50 gal 60.9 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft2 DUCTS / —Supply— —Return Air CFM 25 CFM25 HVAC# V # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool 1 Attic 6 115 ft2 Hall 35 ft2 Default Leakage Laundry (Default) (Default) 1 1 TEMPERATURES Programable Thermostat: Y Ceiling Fans:Cooling Vent Jan Feb Mar Jan Feb Apr f �X DC] Jun [ l Jul I ] Aug I I �X [ Sep [ ] L.l r0('i Dec ng [X� Mar X� ApNV r May Jun [ Jul [ 1 Aug [ Sep lxl Oct [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Cooling (WD) AM 78 78 78 78 78 78 78 78 80 80 80 80 PM 80 80 78 78 78 78 78 78 78 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 78 78 PM 78 78 78 78 78 78 78 78 78 78 78 78 Heating (WD) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 Heating (WEH) AM 66 66 66 66 66 68 68 68 68 68 68 68 PM 68 68 68 68 68 68 68 68 68 68 66 66 4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 5 of 6 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbs/sq.ft. 0 ft' 0 ft 0.3 Master Bath Default(8 lbs/sq.ft. ft' ft 0.3 Master Closet Default(8 lbs/sq.fL W ft 0.3 Master Bedroom Default(8 lbs/sq.ft. ft' ft 0.3 Kitchen Default(8 lbs/sq.ft. ft' ft 0.3 Dining Default(8 lbs/sq.ft. W ft 0.3 Family Room Default(8 lbs/sq.ft. ft' ft 0.3 Bedroom 3 Default(8 lbslsq.ft. ft' ft 0.3 Laundry Default(8 lbs/sq.ft. ft' ft 0.3 Bathroom Default(8 lbs/sq.ft. ft' ft 0.3 Bedroom 2 Default 8lbs/s .ft. W ft 0.3 Hall Name: Signature:QOVlldlJ�\'/Ic Q.IdJ Rating Compant: Date: 0-lo -lal 4/10/2019 4:29 PM EnergyGauge® USA Section R405.4.1 Compliant Software Page 6 of 6 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: Pauley Residence Builder Name: Street: XXX Seminole Road Permit Office: St. Lucie County City, State, Zip: Fort Pierce, FL, 34951 Permit Number: Y Owner. Pauley Residence Jurisdiction: St. Lucie County w Design Location: FL, Fort Pierce U COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall requirements The exterior thermal envelope contains a continuous air barrier, not be used as a sealing material. Breaks or joints in the air barrier shall be sealed. Ceiling/attic The air barrier in any dropped ceiling/soffit shall be aligned with The insulation in an dropped ceiling/soffit Y the insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs or knee wall doors to unconditioned attic spaces shall be sealed. Walls The junction of the foundation and sill plate shall be sealed. Cavities within comers and headers of frame walls The junction of the top plate and the top of exterior walls shall be shall be insulated by completely filling the cavity sealed, with a material having a thermal resistance of R-3 Knee walls shall be sealed. per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment with the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of Floor framing cavity insulation shall be installed to (including insulation. maintain permanent contact with the underside of above -garage subfloor decking,or floor framing cavity g insulation and cantilevered shall be permitted to be in contact with the top side floors) of sheathing, or continuous insulation installed on the underside of floor framing and extends from the bottom to the top of all perimeter floor framing members. Crawl space walls Exposed earth in unvented crawl spaces shall be covered with Where provided instead of floor insulation, insulation a Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace Shafts, penetrations Duct shafts, utility penetrations, and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities shall be curt to fit, or narrow Narrow cavities cavities shall be filled by insulation that on installation readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spac s. Recessed lighting Recessed light fixtures installed in the building thermal envelope Recessed light fixtures installed in the building shall be sealed to the drywall. thermal envelope shall be airtight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring and plumbing in exterior walls, or insulation that on installation readily conforms to available space shall Shower/tub The air barrier installed at exterior walls adjacent to showers and Exterior walls adjacent to showers and tubs shall on exterior wall tubs shall separate them from the showers and tubs. be insulated. Electricallphone box or The air barrier shall be installed behind electrical or communication exterior walls boxes or air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shall be sealed to the sub -floor or drywall. Concealed When required to be sealed, concealed fire sprinklers shall only be J sprinklers sealed in a manner that Is recommended by the manufacturer. Caulking or other adhesive sealants shall not be used to fill voids between fireliclijoider QQY9LVjatU and Wall or cellings I a. In addition, inspection of log walls shall be in accordance with the provisions of ICC400. 4/10/2019 4:30 PM EnergyGauge® USA FBC 6th Edition (2017) Compliant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX* = 92 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location & insulation level a) Supply duds R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Hall 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 3 13. Cooling system: Capacity 35.4 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 1845 d) Room unit/PTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.250 14. Heating system: Capacity 27.0 c) Area 7c. 174.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor.(weighted average) 8a. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.95 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior. d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 0 Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 1081. 11.0 2. Masonry (Insulation R-value) 10132. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans Yes a) Under attic 11a. 38.0 b) Cross ventilation No b) Single assembly 11b, c) Whole house fan No c) Knee walls/skylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11d. No e) Multizone heating credit 0 Programmable thermostat Yes *Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT. I certify that this home has comp the Florida Building Code, Energy Conservation, through the above energy saving features which will be i to% led (or exceeded) in this home before final inspection.7th8ise, a new EPL display card will be complete b 5ed on i stall d code compliant features. Builder Signature: ✓� Date: Address of New Home: XXX Seminole Road City/FL Zip: Fort Pierce, FL 34951 411012019 4:30:08 PM EnergyGaugeO USA 6.0.02 - FlaRes2017 FBC 6th Edition (2017) Compliant Software Page 1 of 1 -F- wrightsoftProject Summary Entire House Quick Calcs, Inc. 317 St. Lucie Lane, Fart Pierce, FL 34946 Phone: 7724666799 avail: quickcal For: Notes: SCANNEDFILE COPY.oat: BN Pauley Residence XXX Seminole Road, Fort Pierce, FL 34951 APR 17 niq ST_Lucie county, pernt Design Information Weather: Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 grAb Heating Summary Structure 18516 Stun Duds 5683 Stun Central vent (0 cfm) 0 Stuh (none) Humidification 0 Btuh Piping 0 Btuh Equipment load 24199 Btuh Infiltration Method Construction quality Fireplaces Simplified Average 0 Heat' t845 C00 J Area (ft� Volume (it) 14760 14760 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 93 49 Heating Equipment Summary Make Trade Model AHRI ref Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 100 EFF 6.6 kW 22524 Btuh 17 OF 1180 cfm 0.049 cfm/Btuh 0.50 in H2O Sensible Cooling Equipment Load Sizing Structure 17343 Stun Duds 8147 Btuh Central vent (0 cfm) 0 Stun (none) Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.95 Equipment sensible load 24216 Btuh Latent Cooling Equipment Load Sizing Structure 4255 Stun Ducts 2220 Stun Central vent (0 cfm) . 0 Stun (none) Equipment latent load 6476 Btuh Equipment Total Load (Sen+Lat) 30692 Btuh Req. total capacity at 0.70 SHR 2.9 ton Cooling Equipment Summary Make Rheem Trade RHEEM Cond RA1636AJlNB Coil RH1T3617STANAA AHRI ref 7942207 Efficiency 13.0 EER, 16 SEER Sensible cooling 24780 Btuh Latent cooling 10620 Stun Total cooling 35400 Btuh Actual air flow 1180 cfm Air flow factor 0.046 cfm/Btuh Static pressure 0.50 in H2O Load sensible heat ratio 0.80 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. _ wrightzsoft' 2019-Apr-1016.26:29 1 Right -Suite® universal 201919.0.01 RSUD8101 Pagel ACCk .-TowmeWWrightsoft HVACtPauley resieence.rup Calc=MJ8 Front Door faces: N wrightsoft• Right-J® Worksheet Job: Enure House Date: Quick Calcs, Inc. By. 317 St. Lude Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcslcs@aol.wrn 1 2 3 4 Room name Exposed wall Room height Room dimensions Room area Entire House 174.0 R 8.0 R 1845.0 fl2 Master Bath 24.0 R 8.0 R heaticeol 14.0 x 10.0 it5 140.0 ft' Ty Construction number U-valu {Btuh/ftZ-FJ� Or HTM I (Bluh/ftq Area (ft') I- or perimeter (R) Load I (Btuh) I Area _(fl') or perimeter (R) I Load (BNh) Heat Cool Gross I WP/S Heal I Cool Gross I WP/S Heat I Cool 8 11 �13A-4ecs. �' 4AS2em' 4AS2em 4A5-2orn _11D0_�-., laA,.,�_ 4A5-2em 4A -Zom 13A40es 10D-m- - 4A5.2om 4A5,2om_.___, 13A4ocs 0.t43 0.770 0.770 0.770 �-0.390 0.143 0.770 0.770 0.143 1.380 -0.770 -__0.770 0.143 n n n n -n- a a _ e a s s _a_ w 4.00 21.56 21.56 21.56 _._10.92 4.00 21.56 21.56 4.00 38.92 21.56 _21.56, 4.00 2.19 19.31 19.31 19.31 -10.34 2.19 47.10 47.10 2.19 20.03 19.31 -19.31. 2.19 . 440 30 30 10 ___20 344 9 30 _ 0 44 41 9 75 168 _ - 349 0 0 0 ___,20 305 0 _ 0 �375 41 9 75 168 1399 647 647 220 __---223 1221 194 647 1502 1588 194 323 673 _ �784 579 579 197 --211 667 424 1413 821 817 174 __290 368 __ A 0 0 0 -.__--0 8o 9 0 -� 0 0 0 0 .___ „0 71 0 0 -_�-0--- 0 0 0 ,�___-0 284 194 0 -0 0 0 0 ,-__... -0 155 424 0 _ _ G _ y 112 0 0 __0 0 _ 112 0 0 ___0 0 ---� 448 0 0 __._--- 0 0 _ _ 245 0 0 .____0 0 W C.�= F ]BBE388tl �_ 22A-Ipl -__0.026 0.989 _ �__0.73. 27.69 � 1.30 0.00 ,-1845 1045 _ 1845 174 _1343 4818 _ �_-_2399 0 _ __740 140 _._-140 24 -- _702 665 ^.. _. 10 0 61 c) ASO excursion 0 30 Envelope losa/gain 15639 9702 1693 t037 12 a) Infiltration b) Roonlventilation 2877 0 811 0 397 0 112 0 13 Internal gains: Occupants@ 230 Appllances'other 11 2530 430 0 1 0 0 Subtotal Qines 6 to 13) 1 18516 17343 1 2090 1148 14 15 Less external load Less transfer Redistribution Subtotal Duct leads 31% 47% 0 0 0 18518 5683 0 0 0 17343 8147 31% 47% 0 0 0 2090 641 0 0 0 1148 539 TotsAir re redl(1 I I 277 01 2118 I 1 1 21331 7fi781 Calculations approved by ACCA to meet all requirements of Manual J Sth Ed �I} wra9heso,� 2019-Apr-1016:26:29 Right-Suitelece.rup Calee1919.0.ro RSUr face Pagel ...\Documents\WrighLsoR HVAC1Pauley residence.rup CaIc=MJB Front Door faces: N wrightsoft Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.00m 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Master Closet 0 8 8.0 0 heat/cool 10.0 x 8.0 8 80.0 fl' Master Bedroom 47.0 0 8.0 8 heat/cool 1.0 x 298.0 it 298.0 fl' Ty Construction number ll-value j (Btuh/ft;°F Or I HTM (Btuh/ft') I Area (ft') or perimeter (8) I Load I (Btuh) Area (W) I or perimeter (fi) Load (Bluh) Heal Cool rG.Sa N/P/S Heat Cool Gross WP/S Heat Cool B 17 13A-0oce 4A5-2om 4A5-2om 4AS-20M 11D0-_,- 13A-4ocs 4A5-2om 4A8-2om 0143 0770 0770 0770 - -0.390 0.143 0.770 0.770 n n n n _:n_ a a a -- 400 2156 2156 2156 _10.92 4.00 21.56 21.56 2.19 19.31 19.31 19.31 ._70.34 '----0 - 0 0 0 -0 �_-0 0 0 0 -.___0 _ _ 0 0 0 0 ---0 0 0 0 � 0 0 0 0 --._0 _ 712 15 0 .0 .__0 '- 97 0 0 0 ___0--- -' 388 323 0 0 _0 745 0 647 �212 290 0 0 -----0 407 0 1413 W L�-GG 2.19 47.10 47.10 0 0 0 0 0 0 0 0 0 215 0 30 186 0 0 - W .C_-_..18&38aC-'-: F 13A4ocs 70D-m 4A5-2om 4A52om 13A-0nce 22A-tpl '-- 0.143 1.390 0.770 �.0.770 0,143 w_0.026 0.989 s a s -a_ w 4.00 38.92 21.56 _.21.56, 2. 99 20.03 19.31 _19.31 _ _ �- 0 0 0 __ 0 � 0 0 0 ,_,__0 _ '0 0 '0 _._0 0 0 0 __0 __ 0 0 0 __0 0 0 0 0 48 _,._.298 47 0 0 0- ___O 192 _--_217 1302 0 0 0 v- _0 105 _.y- 387. 0 4.00 ..`_0.73. 27.69 2.19 __1.30 0.00 0 -_80 80 0 __--:80 0 0 _. _58 0 _ 0 .:104 0 48 __298 298 8 c)AED excursion 0 -8 Envelope loss/gain 58 104 3814 28; 12 a) Infiltration b) Room ventilation 0 0 0 777 0 219 0 13 Internal gains: Occupants@ 230 Appliances/omer 0 0 0 2 "0 900 Subtotal (lines 6 to 13) 1 58 104 1 1 4591 4385 14 15 Less external lead Less transfer Redisbibution Subtotal Ductleads 31% 47% 0 0 0 58 18 0 0 0 104 49 31% 47% 0 0 0 4591 1409 0 0 0 4385 2060 A!rrequlet reNdl(cfm) I I I 741 157I I I 6293I 110 6288I Calculations aooroved by ACCA to meet all requirements of Manual J 8th Ed. - =':L ^o� 2019-Apr-1016:26:29 Right -Suite® U niversal 201919.0.01 RSU08101 Paget ...TocumentslWrightsoft HVACTauley resieence.rup Calc=MJ8 Front Dow faces: N wrightsoft• Right -JCS Worksheet Job: Entire House Date. Quick Calcs, Inc. By. 317 St. Lucie Lane, Fart Pierce, FL 34946 Phone: 772-466-6799 Email: qulckcalcs@aol.com 1 2 3 4 5 Room name Exposed wall Roam height Room dimensions Room area Kitchen 14.0 R 8.0 R heall000l 14.0 x 18.0 It 252.0 fl' Dining 12.0 It 8.0 It heaycool 12.0 x 18.0 R 216.0 ft' Ty Construction number U-value (Stuhlftk'F Or KM (Btuhffl') Area (f") I or perimeter (R) I Load (Btuh) I Area (fl') or perimeter (ft) _I Load (BNh) Heat Coal Gross NINS Heat Cool Gross N/P/S Heat Cool 6 11 -�O.a_ 0 0 0 __0 0 0 0 0 0 0 0 _0 0 0 0 U 0 0 0 __- _.0 0 0 0 _ �O 0 0 0 ___.0 0 0 0 0 0 0 0 ___0 0 0 0 ____. 0 0 0 0 __0 0 0 0 0 0 0 0 _.__,0 0 0 0 -_�.. 0 0 0 0 �:------- 0 0 0 0 -- Y3A-4ocs. 4A5-2om 4A5-2mn 4A5-tom" .11D0-_____ 13A.40 a 4AS-2om 4AS2om �- 0143 0770 0770 0770 ..__..__0,390 0.143 0.770 0.770 n n n' n _n- a a e_ 400 2156 2156 21M -1092 4.00 2156 2156 2.19 19.31 19.31 19.31 -10.34 2.19 47.10 47.10 _ W �G �G _ W -C__.._ F _ 13A-flocs- 4OD-m 4A5-2om - 4A5-20m_.- 13A4ocs 0143 - 1390 0770 -...,_.0770 0.143 's s s -s_. w --400 38.92 21.56 _21.56 4.00 2.19 20.03 19.31 ,_19.31 2.19 112 0 9 _-_.__0 0 _ 103 0 9 ----0 0 .252 14 412 0 194 _______0 0 183 388 _ 225 0 174 -_._0 0 .___328 0 96 41 0 ---- -0 0 '65 41 '0 _-_0 0 _ 221 - 1588 0 ___0 121 817 0 _.,.__. 0 0 -___ 281. 0 0 ,16&'38ed _- PLO!_ -_0.026 0.989 l= �_ _ _0.73 _ _1.30 2.00 ^252 252 __218 _ _. 216 __216 12 _ ___157. _ _-_ 332 _27.69 - 61 0) AED excursion Envelope losstgain 1 1178 721 2299 1215 12 a) Infiltration b) Room ventilation 231 0 65 0 1 198 1 0 56 0 13 Internal gains: Occupants@ 230 Appliancestother 2 460 2000 2 460 0 Subtotal (lines 6 to 13) 1 1409 3248 1 1 2497 1731 14 15 Less external load Less transfer Redistibution Subtotal Duct loads 31% 47% 0 0 0 1409 432 0 0 0 3248 1525 31% 47% 0 0 8 2505 769 0 0 14 1745 820 TotaAir regred(.b I I I 1 90I 4221I I I 3160I 2179 Calculations approved by ACCA to meet all requirements of Manual J Sth Ed -1- 2019-Apr.1016:26:29 . A Right -Suite® Universal 201919.0.01 RSU08101 Page ...1Documents\Wdghtsoft HVACIPauley residence.rup rate =MJ8 Front Door faces: N wrightsoft' Righter Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lude Lane, Fort Pierce, FL 34946 Phone: T72-466-6799 Email: quiokcelcs@)aoLwnn 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Family Room 26.0 ft 8.0 ft heaVwol 28.0 x 13.0 8 338.0 f[' BW=m 3 14.0 ft 8.0 ft heallcool 14.0 x 11.0 ft 154.0 ft' Ty ConsWct= number - U-value {Btuh/tK°F Or j M (Btuh/ft') Area (ft2) I- or penmstar (ft) Load I (Stub Area (ft') I or perimeter (ft) Load I (Brun) Heat I Cool Gross I N/P/S I Heal I Cool Gross I N)P)S Heat Cool 6 11 _ 73A-flocs 4A5-2om 4AS2om 4AS26m AIDO 13A-floes 4AS2om 4AS2om ^ 0143 __ 0770 0770 0770 -0.390 0.143 0.770 0.770 n h a n .._n_ a a e_ 400 2156 2156 2156 -1092 4.00 21.56 21.56 2.19 19.31 19.31 19.31 __10.34 2.19 47.10 47.10 --208 0 30 10 -20 0 0 0 147 0 0 0 `.20 0 0 0 590 0 647 220 223 0 0 0 322 0 579 197 _ __211 0 0 0 -0 0 0 0 _-0 0 0 0 ~0 0 0 ' 0 -___0 0 0 0 -0 0 0 0 - ---0 0 0 0 0 0 0 '0 �._.._. 0 0 0 0 Yy ��__GG 13A-4ba '-- 1OD-rn _ 4AS2om AA5r20m_.. 13A-4ocs 0.143 1.390 0.770 ...,._0.770 0.143 s s s ,.ems_ w 4.00 38.92 21.56 _. 21.56 4.00 2.19 20.03 19.31 __.19.31 2.19 0 0 0 .V__.0 0 -- _ 0 0 0 ._0 0 ' 0 0 0 __..._0 0 0 0 0 ,_. _O 0 112 0 0 __._15 0 97 0 0 �- 388 0 0 ___ _323, 0 1-212 0 0 �.290 0 - W _.�75 0 C... �, F _ .i6B38a'd 22A-Ipl =W0.026 =_0.73..�1.30 =---338 _ 338 26 �. 446---430 720 -154 164 =11,12 ... 200 0 0989 27.69 0.00 _ 338 0 164 _,14 _ 388 61 c) AED excursion Envelope lesslgain 2648 1743 1212 700 12 a) Infiltration b) Room ventilation 430 0 121 0 231 0 65 0 13 Internal gains: Occupants @j 230 Appliances/other 2 460 900 1 230 0 Subtotal (lines 6 to 13) 3076 3224 1443 995 14 15 Less external load Less transfer Redistribution Subtotal Dud loads 31% 47% 0 0 5 3081 946 0 0 70 3234 1519 31% 47% 0 0 4 1447 444 0 0 8 1003 471 LI quired Air re(cfm) I I I 4098I 4�9I I I 18992I 1468 Calculations awroved by ACCA to meet all requirements of Manual J 8th Ed =Iatrs soft- 2019-Apr-1016:26:29 Right -Suite® Universal 201919.0.01 RSU08101 Page ...100cuments\Wrightsofl WACIPauley residence.rup Cale=M,18 Front Door faces: N wrightsoft• Right-M Worksheet Job: Entire House Date: Quick Calcs, Inc. By. 317 St. Lucie Lane, Fort Pierce, FL 34W Phone: 772466-6799 Email: quickmlcs@aol.com 1 2 3 4 5 Room name Exposed wall Room height Room dimensions Room area Laundry 0 ft 8.0 ft heat(cool 10.0 x 6.0 ft 60.0 ft' Bathroom 1.0 ft &0 ft heaVwol 10.0 x &0 ft 60.0 ft2 Ty construction number U-value (BIuiVfR°F j Or HiM I (Bluhf t= Area (ft2) I or perimeter (ft) Load I (Btuh) Area (fP) I or perimeter (ft) Load I (Btuh) Heat Cool Gross WP/5 Heat Cool Gross WP/S Heat Cool 1 T- 6 17 ll�--ODD 13A-4acs 4A5-tom 4A5-2orn _ 4A5-tom 11D0 13A.4ocs 4AS-2om 4Ai2om - 0143 0770 0770 0770 -0.390 0.143 0.770 0770 n n n n -n_ a a _e � 400 2156 2156 _ �21.58 --10.92 4.00 21.56 2156 2.19 19.31 19.31 19.31 _10.34 2.19 47.10 47.10 0 0 0 -- 0- _0 0 0 0 _ 0 0 - 0 0 •0 0 0 0 --0 01 .0 0 __.__-0�0 0 0 0 -0 0 0 0 0 0 0 0' 00 0 0 0 0 ,0 0 0� 0. 0 -0 '0 0 -0 -0 VIA �f �G 0 0 0 0 0 0 0 0 --a 0 0 0 0 0 0 13A-0ad. aF'- 10D-m _ _ 4A5-2om '_ 4AS20m 13A-4ocs - 0143 1390 '0770 --0.7,70 0.143 s-. 5 s. ._s„ w 400 3892 . _2156 -.21.56 4.00 fl9 20.03 19.31 -19.31, 2.19 _ ' 0 0 0 - 0 0 0 .0 ____0 0 - 0 0 r,.__0 0 0 0 0 _0 0 _ 0 - 0. '0 0 0 0 _ -0 -� 0 _ '0 ^ 0 ..,_.� -0 _ � 0 0 0 -,._-0 �G L-G W 0 0 0 0 8 8 32 18 F -16B;38adL._..;.�.:_ 22A-tpI __-�_ ,:.0. 226 �- 0.989 - - cs073 27.69 . _7.30 0R00 ____e_60 fi0 = 60 0 ._.._44 0 ,. -„ .78 0 _=60 80 =60 1 _�- _44 28 78 0 `. 6 c) AED excursion _7 0 Envelope loss/gain 44 77 703 95 72 a) Infiltration b) Room ventilation 0 0 0 0 17 0 5 0 13 Internal gains: Occupants @ 230 Applianceslother 0 0 500 0 0 0 Subtotal (lines 6 to 13) 44 577 120 100 14 15 Less external load Less transfer Redistribution Subtotal Duo loads 31% 47% 0 0 7 50 15 0 0 12 589 276 31% 47% 0 0 7 126 39 0 0 12 112 52 m load Nr acquired(dra) I I I 6840I 63I I I 1681 1 8I Calculations awroved by ACCA to meet all reauirements of Manual J 8th Ed -�Mff co>�C- 2019-Apr-1016:26:29 Right -Suite® Universal 201919.0.01 RSU08101 Page ...1DocumentsWightsoft HVACIPauley residence.mp Cale =MJB Front Door faces: N Zo NA m N m H 5. v a T m m 6 3a g v° $-c3 c I � I + !o:o�loop�000�� Tm impip i! �� Il i► ° {iv!{8! _ o �° Ci Ii► i� �! f� 4� I �� f� i i� gi gI, �s f11� I fl �I }1 �1 it ,1 I 11 I �l O, INbb ON JJN Om bb N J m - �� {I � l{ II 1, I, {a 11 {1►{o�m„�, biOOm b 1111I!II!I 1j1j 111d m N i f 1 9 C i I I{ . I i II mb _ NOOOm pI OO OOONOI m a 3^ b O O I I b N 1 ( I I f� F� � � 1 ! �Im Ala• m b NN W� p iJ O0AOO fNil Olbll 0 }I II { I{ f1 II II �! I I' 1 I I JN m�O O'O N!OON OO O(J OI ObNOOOm OOm OOOOOI ! r + `s I I I � +mm 000 oo 0000000'0l 3,� o c A 0 I Om•OOO OOIOOO OO OOO _ + I { i'; ! I i t + to Nl000 ooi000 oo 000, m m I 00 OONOO N 00 00 N O I I I I• 11 � � I I I 1 j • I I I�� . l I{ g.l ! ' } I � m�, ` I ON•OOO OO1OOO OO'OOO� — Duct S stem Summa Job: wrightsoft° y � Date: Entire House By: Quick Calcs, Inc. 317 St. Lucie Lane, Fort Pierce, FL 34946 Phone: 772-466-6799 Email: quickcalcs®aol.com Project• • For: Pauley Residence XXX Seminole Road, Fort Pierce, FL 34951 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.356 in/100ft 1180 cfm 141 ft Cooling 0.50 in H2O 0 in H2O 0.50 in H2O 0.250 / 0.250 in H2O 0.356 in/100ft 1180 dm Supply Branch Detail Table Name Design (Btuh) Htg (dm) Clg (dm) Design FIR Diam (in) H x W (in) Dud Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bathroom h 165 8 8 0.501 4.0 Ox0 VIFx 9.9 90.0 st1 Bedroom h 4127 201 121 0.472 8.0 Ox0 VIFx 16.0 90.0 SO Bedroom h 1892 92 68 0.501 7.0 OXO VIFx 9.9 90.0 st1 Dining h 3273 160 119 0.449 8.0 Ox 0 VIFx 21.2 90.0 st3 Family Room c 2376 98 110 0.356 7.0 OXO VIFx 30.6 110.0 st4 Family Room -A c 2376 98 110 0.360 7.0 OXO VIFx 29.0 110.0 st4 Kitchen c 2385 45 110 0.431 7.0 Ox0 VIFx 26.1 90.0 st3 Ktchen-A c 2385 45 110 0.442 7.0 Ox0 VIFx 23.0 90.0 st3 Laundry c 865 3 40 0.516 5.0 Ox0 VIFx 6.8 90.0 SO Master Bath h 2732 133 78 0.364 7.0 Ox0 VIFx 47.4 90.0 st2 Master Bedroom c 3223 146 149 0.371 7.0 Ox0 VIFx 44.8 90.0 st2 Master Bedroom -A c 3223 146 149 0.386 7.0 Ox0 VIFx 39.4 90.0 st2 Master Closet c 153 4 7 0.386 4.0 Ox0 VIFX 39.6 90.0 st2 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (dm) (dm) FR (fpm) (in) (in) Material Trunk st2 Peak AVF 430 384 0.364 547 12.0 0 x 0 VinlFlx st4 Peak AVF 196 220 0.356 498 9.0 0 x 0 VinlFlx st3 st3 Peak AVF 446 560 0.356 523 14.0 0 x 0 VinlFlx st1 Peak AVF 305 237 0.472 559 10.0 0 x 0 VinlFlx -Ok wrightsoft- 2019-Apr-1016:26:29 ^•� •-•-• ..�...-. RighlSuite® Universal 201919.0.01 RSU08101 Pagel / .G1 ...1D1wmen1%1Wnghteoft HVACTauley residence.mp Gale =MJ8 Front Door faces: N Return Branch Detail Table Name Grille Size (in) Htg (dm) Clg (dm) TEL (it) Design FIR Veloc Opm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matl Trunk rb1 Ox0 1180 1180 0 0 0 0 Ox 0 1 VIFx wrightsoft• 2019-Apr-1016:26:29 .-. �..._. Right-Suite®Universal201919.0.01 RSU08101 Paget +Cp... l0ooumentsXMghtsofl HVACWauleyresideoae.rup Cale=MJ8 Front Doorfaces:N