Loading...
HomeMy WebLinkAboutENERGY EFFICIENCY CODEFORM R405-2017 FLORIDA ENERGY EFFICIENCY CODE FOR BUILDING CONSTRUCTION Florida Department of Business and Professional Regulation - Residential Performance Method Project Name: WEINERT RESIDENCE Builder Name: RON RAYMOND CONSTRUCTION SCANNED Street 17803 BRIDLE WAY Permit Office: ST LUCIE COUNTY BY City, State, Zip: FORT PIERCE, FL, Permit Number ♦ I St. Owner: Jurisdiction: ST LUCIE-COUNTY Lucie County �i Design Location: FL, Fort Pierce County St Lucie (Florida Climate Zone 2) 1. New construction a existing New (Fran Plans) 9. Wall Types(3280.3 sgfL) Insulation Area 2. Single family or multiple family Single-family a. Concrete Block - F)d Insul, F)¢erior R=4.1 2856.30 fN b. Frame - Wood, Adjacent R=11.0 424.00 it' 3. Number of units, if multiple family 1 c. NIA R= 11' 4. Number of Bedrooms 4 d. N/A R= it, 10. Ceiling Types (2424.0 sgfL) Insulation Area 5. Is this a worst case? No a- Under Attic (Vented) R=30.0 2424.00 f' 6. Conditioned floe area above grade (112) 2424 b. NIA R= it, c, R= fft Conditioned Boa area below grade (ft') 0 11. Duuctct s R fN 7. Windows(596.0 sgft) Description Area a. Sup: Attic.. Rat Attic, AH: Garage 6 120 a. U-Factor. sgl, U=0.65 372.00 fN b. Sup: Attic, Ret: Attic, AH: Garage 6 130 SHGC: SHGC=025 12. Coding systems kBtu/hr Efficiency b. U-Factor. Sgl, U=0.65 224.00 IF a. Central Unit 18.8 SEER:16.00 SHGC: SHGC=0.30 b. Central Unit 29.4 SEER:16.00 c. U-Factor. N/A fN SHGC: 13. Heating systems kBtulhr Efficiency d. U-Factor. NIA ft' a. Electric Strip Heat 17.0 COP:1.00 SHGC: b. Electric Strip Heat 27.0 COP:1.00 Area Weighted Average Overhang Depth: 4215 it Area Weighted Average SHGC: 0269 14. Hot water systems a Electric Cap: 50 gallons 8. Floor Types (2424.0 sgft) Insulation Area EF: 0.980 a. Slab -On -Grade Edge Insulation R=0.0 2130.00 fN b. Conservation feaNres b. Raised Floor R=30.0 294.00 B2 None a NIA R= ft 15. Credits None Glass/FloorArea: 0.246 Total Proposed Modified Loads: 86.26 PASS Total Baseline Loads: 92.58 f1.7�7 1 hereby certify that the plans and specifications covered by Review of the plans and oFi11E SrArF this calculation are in compliance with the Florida Energy specifications covered by this indicates Code. calculation compliance with the Florida Energy Code.+<..,'f+•.: PREPA D Y: Before construction is completed DATE: this building will be inspected forcompliance with Section 553.908 I hereby certify that this i esigned, is in compliance Florida Statutes. 1�F4 C. with the Florida En y Co ID OW NER/AGENT' BUILDING OFFICIAL: DATE: DATE: r� - Compliance requires I certification by the air handler unit manufacturer that the air handler enclosure qualifies as certified factory -sealed in accordance with R403.3.2-1. - Compliance requires an Air Barrier and Insulation Inspection Checklist in accordance with R402.4.1A and this project requires an envelope leakage test report with envelope leakage no greater than 7.00 ACH50 (R402.4.1.2). - Compliance with a proposed duct leakage Qn requires a Duct Leakage Test Report confirming duct leakage to outdoors, tested in accordance with ANSIIRESNET/ICC 380, is not greater than 0.030 Qn for whole house. 312612019 9:43 AM EnergyGaugeOO USA Section R405.4.1 Corgp�t�fL copy Page 1 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT PROJECT Tille: WEINERT RESIDENCE Bedrooms: 4 Address Type. Street Address Building Type: User Conditioned Area: 2424 Lot # Owner Name: Total Stories: 1 Block/Subdivlsion: # of Units: 1 Worst Case: No PlatBoolc Builder Name: RON RAYMOND CONSTRU Rotate Angle: 0 Street: 17803 BRIDLE WAY Permit Office: ST LUCIE COUNTY Cross Ventilation: No County. SL Lucie Jurisdiction: ST LUCIE COUNTY Whole House Fan: No City, State, Zip: FORT PIERCE, Family Type: Single-family FL, New1Ewstmg: New (From Plans) Comment: CLIMATE / Design Temp Irt Design Temp Heating Design Daly Temp V Design Location TMY Site 97.5 % 25 °/ Winter Summer Degree Days Moisture Range FL, Fort Pierce FL_VERO_BEACH_MUNI 39 90 70 75 299 62 Low BLOCKS Number Name Area Volume 1 AHU 1 869 7796.1 2 AHU 2 1555 16799.7 SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infil ID Finished Cooled Heated 1 MASTER SEDROO 225 2092.5 No 0 1 1 Yes Yes Yes 2 MWIC 69 642 No 0 1 Yes Yes Yes 3 M BATH 174 1614 No 0 1 Yes Yes Yes 4 MTOILET 20 186 No 0 1 No Yes Yes 5 LAUNDRY 63 595.9 No 0 1 No Yes Yes 6 LINEN 6 55.8 No 0 1 No Yes Yes 7 HALL 18 167.4 NO 0 1 No Yes Yes 8 BONUS ROOM 238 1927.E No 0 1 Yes Yes Yes 9 STAIRS UP 56 520.8 No 0 1 Yes Yes Yes 10 NOOK 63 756 No 0 1 Yes Yes Yes 11 LIVING ROOM 342 4104 No 0 1 Yes Yes Yes 12 DINING 130 1560 No 0 1 Yes Yes Yes 13 FOYER 91 1092 No 0 1 Yes Yes Yes 14 DEN 130 1560 No 0 1 Yes Yes Yes 15 BEDROOM 4 151 1404.3 No 0 1 1 Yes Yes Yes 16 CLST 4 18 167.4 No 0 1 Yes Yes Yes 17 BATH 3 54 5022 No 0 1 Yes Yes Yes 18 CLST 3 18 167A No 0 1 Yes Yes Yes 19 BEDROOM 3 151 1404.3 No 0 1 1 Yes Yes Yes 20 HALL 3 24 223.2 No 0 1 No Yes Yes 21 CLST 2 26 241.8 No 0 1 Yes Yes Yes 3/26/2019 9:43 AM EnergyGaugvD USA Section R405A.1 Compliant Software Page 2 of 8 Cnonn PAn�,?017 IMP] IT RLIMMARY CHFCKI_IRT RFPART SPACES Number Name Area Volume Kitchen Occupants Bedrooms Infi11D Finished Cooled Heated 22 BEDROOM 2 169 1571.7 No 0 1 1 Yes Yes Yes 23 HALL 24 2232 No 0 1 Yes Yes Yes 24 BATH 2 54 502.2 No 0 1 Yes Yes Yes 25 KITCHEN 110 1320 Yes 0 1 No Yes Yes FLOORS # Floor Type Space Perimeter Perimeter R-Value Area Joist R-Value Tile Wood Carpet 1 Slab -On -Grade Edge Insulatio MASTER SEDRO 26.9 it 0 225 ft' — 1 0 0 2 Slab -On -Grade Edge Insulatio M W IC 18 ft 0 69 ft2 — 1 0 0 3 Slab -On -Grade Edge Insulatio M BATH 14.9 It 0 174 ft' — 1 0 0 4 Slab -On -Grade Edge Insulatio M TOILET 1 it 0 20 ft2 — 1 0 0 5 SlalrOn-Grade Edge Insulatio LAUNDRY 1 ft 0 63 ft' — 1 0 0 651ab-On-Grade Edge Insulatio LINEN 1 ft 0 6It' — 1 0 0 7 Slab -On -Grade Edge Insulatio HALL 1 ft 0 18 ft' — 1 0 0 8 Raised Floor BONUS ROOM — — 238 ft' 30 0 1 0 9 Raised Floor STAIRS UP — — 56 IF 30 0 1 0 1051ab-On-Grade Edge Insulatio NOOK 10 it 0 63 f? — 1 0 0 11SIab-On-Grade Edge Insulatio LIVING ROOM 12 ft 0 342 ft' — 1 0 0 12SIab-On-Grade Edge Insulatio DINING 10 ft 0 130 IF — 1 0 0 1351ab-On-Grade Edge Insulatio FOYER 7 ft 0 91 ft' — 1 0 0 14SIab-On-Grsde Edge Insulatio DEN loft 0 130 W — 1 0 0 15SIab-On-Grade Edge Insulatio BEDROOM 4 26 ft 0 151 ft, — 1 0 0 16SIab-On-Grade Edge Insulatio CLST 4 2 ft 0 18 W — 1 0 0 17SIab-On-Grade Edge Insulatio BATH 3 6 ft 0 54 ft2 — 1 0 0 18SIab-On-Grade Edge Insulatio CLST 3 2 ft 0 18 ft2 — 1 0 0 19SIab-On-Grade Edge Insulatio BEDROOM 3 11 ft 0 151 ft7 — 1 0 0 20Sfab-On-Grade Edge Insulatio HALL 3 1 ft 0 24 ft2 — 1 0 0 21SIab-On-Grade Edge Insulatio CLST 2 2ft 0 26 W — 1 0 0 22SIab-On-Grade Edge Insulatio BEDROOM 2 26 ft 0 169 ft2 — 1 0 0 23SIab-On-Grade Edge Insulatio HALL 2 411 0 24 112 — 1 0 0 24SIab-On-Grade Edge Insulatio BATH 2 15 ft 0 64 ft2 — 1 0 0 3/26120199:43 AM EnergyGauge@ USA Section R405.4.1 Compliant Software Page of rn N � b g a. o n a o 0 0 0 0 0 0 o a a ?? 2 n m ii B B B B S n B o n B n c a C. � O TO 3 g -i y p r A rn- 7C.7 0 2 O D D 2 Cyq O m Z O n o C OO r Z D ry O 0 0 0 0 0 0 0 0 0 0 o b o 0 0 0 0 0 0 0 0 o a o< � ry W OggJ IggA W_ CD m IP W m W OJ W N S Q � � gW_g gWg_ cam_c� g0g1 gm_g gm_g 4W_4 gN_g gW_g gW_g gm_g ggW_ sms m N o � � G N A A �j m A � Oo to �� o' O WW N w tNo O� � W � O� W 1N.t O A rn ttl � �• .N. m 8. A T � 0 o a o p p p p o p o p p 0 p p 0 p p o p o K G C C C < G G 4 N C Q�Q QG QC Q�Q g� Q<Q Qp� 5�j QC QG QpK QC QC Q� qC O Q< _ o � m � s T ? W N O b W V 0) N A W N O (O W J W N A W N O m m m m* m* e C*** m z z z m z m m* m* N z* m m z z z m m m* m T 0 0 0 O n O O O O O O O O O O T 0 T O 0 0 G O O O O 0 O T T O 0 0 0 0 9 ry o m m m ry o m m m m o m m m m m m m m m m m m m m m m m m m m m m m m m m m m cu m m m m m m i m m m m m a m m m m m m m m m x ��ggqq ���myq L` W S O O f1 (l m (� O c T rOm mm b zf/! z z O 0_ CNC m :l C-n OZ0 p p xxOOO O O p GI A A Am fll CZ 3D Di 2` _� Nfurl x 2 n O A .Z N N N 3 N W W A 'S O O 9 '9 O O O O{ m m N N W P A A + A- A A A A A j A A A A A A+ A+ A A A A A j j A>- ++ A A A a A O o O o O O O O o o O o O O O O O o O O O O o o O o 0 o O o O o O O O O N b b 10 b t0 b [O lD b �D �O b t0 N N N N N N N N O b (O Co W W W b 4) b w b 0 10 O A A A A A A A A A A A A a 0 0 0 0 0 0 0 0 A A A++++ A A A A A A A (p a O� ? V COONI O) O W O !� OW) O .m ➢ w 0 N m O W O O C 41 tJ Cu V r J 0 V '�Nj � W 0 0 0 O O O O O w V W J b O G <J V O W J <J V 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 T O N 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 F._i O 0 0 0 A) O O O O O O O O O O N 0 0 m g 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Q N IJ fJ IJ N N N fJ fJ N IJ IJ N IV N IJ N N IJ N N N N N N N N N N 1J N N N N N N Rf A O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O O p a r r rn W N N N N W N N N N N N N N h o m N w 0 in 0 z z z z z z z z z z z z z z z z w z W (a N c N Q N D m J V N �j N CN O C N O N NC O N Cd N gl O N C N O CN O ,p � C O O O z z z z z z z z z z z z z z z z z � _ c O v O D O � N g c e c c e e c c �o e ,� c c c e c c c c c c c g a c v v o v v v v v v v v v v o v v v a ul v tO rg N m .�- v .N- M coi m 16 M a r0 i m Q {ryy IL m u .- E n E z Z Z Z Z Z z Z Z z Z z z z Z Z Z z Z Z 2 y N 4d c u 0 v Ul `w U o U a N pp N U N N m N N N N ��OO N UJ N N N N 0 N N N N m N N 0 N ty N N N N N N VI N m N 0 O N N N 0 W 0 a r O F s W m r F CO) W Q = c 0 c o o a o 0 0 0 0 0 0 0 0 0 0 aaq N p Z� N 4 p Z U N N N In YJ In N N IA N N N N N N N 1(f In N In O N J LL O O 0 a O O O O O a OO O O O O OO O O O O OO O Z pj Q all EN U w Z � r N N O n N c m p m z z v v a m v v v v gi v v v v v v C rn C rn C rn C rn C m C a C s G rn C rn C rn C rn C m rn w m w m m rn U a wyyy5y w w wyy55 wySyS w$$ w;; wy5y5 w;; w22 w wy5y5 w22 w22 w;; W; w;; w w�`� JJJ 2 Q ry m v v v v v d a'f v w v dr v S v v v v n n 0 �` f N W 4S — ryry NN E m w w w z w 0 m z z z z z z z 3 3 3 m 3 m 0 W ED O N N L �i cnonn oAnr-')n17 IMPI IT Al IMMARY rHFrKI 1ST REPORT COOLING SYSTEM # System Type Subtype Efficiency Capacity Air Flow SHR Block Ducts _ 1 Central Unit/ Split SEER: 16 18.8 kStLdhr 564 cfm 0.8 1 sys#1 2 Central Unit/ Split SEER: 16 29.4 kBtulhr 882 cfm 0.8 2 sys#2 HOT WATER SYSTEM # System Type SubType Location EF Cap Use SetPnt Conservation 1 Electric None Garage 0.98 50 gal 62.3 gal 120 deg None SOLAR HOT WATER SYSTEM FSEC Collector Storage Cart # Company Name System Model # Collector Model # Area Volume FEF None None ft' DUCTS — Supply— — Return — Air CFM 25 CFM25 HVAC # # Location R-Value Area Location Area Leakage Type Handler TOT OUT ON RLF Heat Cool _ 1 Attic 6 120 W Attic 12 ft- Prop. Leak Free Garage —cfm 26.1 cfm 0.03 0.50 1 1 _ 2 Attic 6 130 ft- Attic 13 W Prop. Leak Free Garage — cfm 46.6 cfm 0.03 0.50 2 2 TEMPERATURES Programable Thermostat N Calling Fans: CoolingHim Heatin[XI jj 77 Feb [[ jj Mar Jan [X) Feb [XI Mar [ ] Apr [ J Apr (] M [Xj Jun [XJ Jul (] M (]Jun (]Jul [JCJ Au [ ]Au[ S ]Sep Oct Oct [(X]� Nov Dec Dec VanNov tin II 7) Jan II 11 Feb II�X1l Mar lxl Apr l 1 May ! 1 Jun l J Jul I 1 Aug 111 117 Sep [X] Nov Dec Thermostat Schedule: HERS 2006 Reference Hours Schedule Type 1 2 3 4 5 6 7 8 9 10 11 12 Coding (WD) AM 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 PM 80 80 80 80 78 78 78 Cooling (WEH) AM 78 78 78 78 78 78 78 78 78 78 80 78 80 78 80 78 80 78 PM 80 80 80 80 78 78 Heating (WO) AM 65 65 65 65 65 65 65 68 68 68 68 68 68 68 68 68 PM 66 68 68 68 68 68 68 68 Heating (WEH) AM 65 65 65 65 65 65 68 68 65 68 68 66 68 68 68 68 68 68 68 68 PM 68 68 68 68 3126/2019 9:43 AM EnergyGauge® USA Section R406.4.1 Compliant Software Page 7 of 8 FORM R405-2017 INPUT SUMMARY CHECKLIST REPORT MASS Mass Type Area Thickness Furniture Fraction Space Default(8 lbslsq.ft. 0 w O ft 0.3 MASTER BEDROO Defsult(8 lbs/sq.ft. ft2 it 0.3 MWIC Default(8 Ibs/sq.fL ft' ft 0.3 M BATH Default(8 Ibslsq.ft. ft2 ft 0.3 M TOILET Defauft(8 lbs/sq.ft. W It 0.3 LAUNDRY Default(8 lbs1sq.fL ft2 ft 0.3 LINEN Default(8 lbs/sq.ft. ft2 If 0.3 HALL Default(8 Ibsfsq.f- ft' ft 0.3 BONUS ROOM Default(8 Ibsisq.fL ft' ft 0.3 STAIRS UP Default(8 lbs/sq.fl. W ft 0.3 NOOK Default(8 Ibs/sq.fL ft' ft 0.3 LIVING ROOM Default(8 Ibs/sq.ft. . ft2 ft 0.3 DINING Default(8 Ibs/sq.fL fe ft 0.3 FOYER Default(8 lbs/sq.ft. ft2 ft 0.3 DEN Default(8 lbslsq.ft. ft' ft 0.3 BEDROOM 4 Default(8 Ibs/sq.ft. W ft 0.3 CLST 4 Default(8 Ibs/sq.ft. ft2 ft 0.3 BATH 3 Default(8 Ibs/sq.ft. W ft 0.3 CLST 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 BEDROOM 3 Default(8 Ibs/sq.ft. ft2 ft 0.3 HALL 3 Default(8 IbslsgJL IF ft 0.3 CLST 2 Default(8 Ibs/sq.fL ft' ft 0.3 BEDROOM 2 Default(8 Ibs/sq.ft. ft' ft 0.3 HALL 2 Default(8 bs/sq.fL It, ft 0.3 BATH 2 Defautt 8 Ibsls .ft. ft2 ft 0.3 KITCHEN Name: Signature: n, Rating Compant: Date: 3/26/2019 9:43 AM EnergyGauge® USA Section R405.4.1 Compliant Software Page 8 of 8 2017 - AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA TABLE 402.4.1.1 AIR BARRIER AND INSULATION INSPECTION COMPONENT CRITERIA Project Name: WEINERT RESIDENCE Builder Name: RON RAYMOND CONSTRUCTION Street 17803 BRIDLE WAY Permit Office: ST LUCIE COUNTY City, State, Zip: FORT PIERCE. FL, Permit Number: V Owner. Jurisdiction: ST LUCIE COUNTY W 2 Design Location: FL, Fort Pierce O COMPONENT AIR BARRIER CRITERIA INSULATION INSTALLATION CRITERIA General A continuous air barrier shall be installed in the building envelope. Air -permeable insulation shall The exterior thermal envelope contains a continuous air barrier. not be used as a searing material. requirements Breaks orjoints in the & barrier shaft be sealed. Ceilinglattic The air bander in any dropped ceiling/sofft shall be aligned with the The insulation in any dropped ceiling/Soffit insulation and any gaps in the air barrier shall be sealed. shall be aligned with the air barrier. Access openings, drop down stairs a knee wall doors to unconditioned attic spaces shall be sealed. Walls The junctionof the foundation and sill plate shall be sealed. Cavities within corners and headers of frame walls The junction of the top plate and the top of exterior wails shall be sealed. shall be insulated by completely filing the cavity with a Knee walls shall be sealed. material having a thermal resistance of R-3 per inch minimum. Exterior thermal envelope insulation for framed walls shall be installed in substantial contact and continuous alignment wdh the air barrier. Windows, skylights The space between window/doorjambs and framing, and and doors skylights and framing shall be sealed. Rim joists Rim joists shall include the air barrier. Rim joists shall be insulated. Floors The air barrier shall be installed at any exposed edge of insulation. Floor framing tarty insulation shall be installed to (including maintain permanent contact with the underside of above -garage subfloor decking, or floor framing cavity insulation shall and cantilevered fleas) be permitted to be in contact with the top side of sheathing, or continuous insulation installed on the underside of flcor framing and extends from the bottom to the top of all perimeter floc framing members. Crawl space walls Exposed earth in unvemed crave spaces shall be covered with a Where provided instead of floor insulation, insulation Class I vapor retarder with overlapping joints taped. shall be permanently attached to the crawlspace walls. Shafts, penetrations Duct shafts, ulifny penetrations. and flue shafts opening to exterior or unconditioned space shall be sealed. Batts in narrow cavities stall be cut to fit, a narrow cavities shall be filled by insulation that on installation Narrow cavities readily conforms to the available cavity spaces. Garage separation Air sealing shall be provided between the garage and conditioned spaces. Recessed lighting Recessed light fixtures installed in the building thermal envelope shall Recessed light fixtures installed in the building be sealed to the drywall. thermal envelope shall be air tight and IC rated. Plumbing and wiring Batt insulation shall be cut neatly to fit around wiring plumbing in exterior walls, or insulation that on installation readily conforms to available space shall extend behind Piping and wiring. Showeritub The air barrier installed at exterior wills adjacent to showers and Exterior walls adjacent to showers and tubs shall be on exterior wall dubs shall separate them from the shovers and tubs. insulated. Electrical phone box on The air barrier shall be installed behind electrical or communication exterior walls boxes a air -sealed boxes shall be installed. HVAC register boots HVAC register boots that penetrate building thermal envelope shag be sealed to the sub -Flea a drywall. Concealed When required to be sealed, concealed fire sprinklers shag only be sealed sprinklers in a manner that is recommended by the manufacture. Caulking or other adhesive sealants shall not be used to fill voids between fire sprinkle cover plates and walls or ceilings. a. In addition. inspection of log walls shall be in accordance with the prmsions of ICC4UU. 312612019 9:43 AM EnergyGauge® USA FBC 61h Edition (2017) Comptiant Software Page 1 of 1 2017 EPL DISPLAY CARD ENERGY PERFORMANCE LEVEL (EPL) DISPLAY CARD ESTIMATED ENERGY PERFORMANCE INDEX' = 93 The lower the Energy Performance Index, the more efficient the home. 1. New home or, addition 1. New (From Plans) 12. Ducts, location R insulation level a) Supply ducts R 6.0 2. Single-family or multiple -family 2. Single-family b) Return ducts R 6.0 c) AHU location Attic/Attic 3. No. of units (if multiple -family) 3. 1 4. Number of bedrooms 4. 4 13. Cooling system: Capacity 48.2 a) Split system SEER 16.0 5. Is this a worst case? (yes/no) 5. No b) Single package SEER c) Ground/water source SEER/COP 6. Conditioned floor area (sq. ft.) 6. 2424 d) Room uniUPTAC EER e) Other 7. Windows, type and area a) U-factor:(weighted average) 7a. 0.650 b) Solar Heat Gain Coefficient (SHGC) 7b. 0.269 14. Heating system: Capacity 44.0 c) Area 7c. 596.0 a) Split system heat pump HSPF b) Single package heat pump HSPF 8. Skylights c) Electric resistance COP 1.0 a) U-factor:(weighted average) Sa. NA d) Gas furnace, natural gas AFUE b) Solar Heat Gain Coefficient (SHGC) 8b. NA e) Gas furnace, LPG AFUE f) Other 9. Floor type, insulation level: a) Slab -on -grade (R-value) 9a. 0.0 b) Wood, raised (R-value) 9b. 30.0 15. Water heating system c) Concrete, raised (R-value) 9c. a) Electric resistance EF 0.98 b) Gas fired, natural gas EF 10. Wall type and insulation: c) Gas fired, LPG EF A. Exterior: d) Solar system with tank EF 1. Wood frame (Insulation R-value) 10A1. e) Dedicated heat pump with tank EF_ 2. Masonry (Insulation R-value) 10A2. 4.1 f) Heat recovery unit HeatRec% B. Adjacent: g) Other 1. Wood frame (Insulation R-value) 10B1. 11.0 2. Masonry (Insulation R-value) 1092. 16. HVAC credits claimed (Performance Method) 11. Ceiling type and insulation level a) Ceiling fans a) Under attic 11a. 30.0 b) Cross ventilation No b) Single assembly 1lb. c) Whole house fan No c) Knee wallslskylight walls 11c. d) Multizone cooling credit d) Radiant barrier installed 11 d. No e) Multizone heating credit f) Programmable thermostat No 'Label required by Section R303.1.3 of the Florida Building Code, Energy Conservation, if not DEFAULT I certify that this home has complied with the Florida Building Code, Energy Conservation, through the above energy saving features which will be installed (or exceeded) in this home before final inspection. Otherwise, a new EPL display card will be co installed code compliant features. Builder Signature: _ , Date: Address of New Home: 17803 BRIDLE WAY City/FL Zp: FORT PIERCE. FL 3/2612019 9:43:48 AM EnergyGaugc& USA 6.0.02 - FlaRes2017 FBC 6th EdMon (2017) Compliant Software Page 1 of 1 Job: wri htsofta Project Summary Date: Mar25,201e 9 AHU 9 By: QUICK CALCS, INC. •. • n LLe Proect Informatidi..�, For. 17803 BRIDLE WAY, FORT PIERCE,RAYFIL CONSTRUCTION SCANNED BY Notes: St. Lucie County z =__.°�•�.u- �u Designlnfo.rmator:, Weather. Fort Pierce, FL, US Winter Design Conditions - Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TO 28 OF Design TD 15 OF Daily range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 13023 Btuh Structure 9572 Btuh Ducts 2246 Btuh Ducts 3373 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 15270 Btuh Use manufacturer's data n Rate/swing multiplier Equipment sensible load 0.95 12298 Btuh Infiltration Method Simplified Latent Cooling Equipment Load Sizing Construction quality Fireplaces Average 0 Structure 3335 Btuh Ducts 891 Btuh Central vent (0 cfm) 0 Btuh Area (ft') Heating 869 Cooling 869 (none) Equipment latent load 4225 Btuh Volume (ft') Air changes/hour 7796 0.49 7796 0.25 Equipment Total Load (Sen+Lat) 16524 Btuh Equiv. AVF (cfm) 64 32 Req. total capacity at 0.70 SHR 1.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR6018J1 AHRI ref Coil TEM4AOB18S21++TDR AHRI ref 8676071 Efficiency 100 EFF Efficiency 13.5 EER, 16 SEER Heating input 4.2 kW Sensible cooling 13160 Btuh Heating output 14401 Btuh Latent cooling 5640 Btuh Temperature rise 21 OF Total cooling 18800 Stuh Actual air flow 627 cfm Actual air flow 627 cfm Air flow factor 0.041 cfm/Btuh Air flow factor 0.048 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.75 FT I COPY Calculations approved by CC to meet all requirements of Manual J Sth Ed. wri9htsoTt- 201"ar-26 08:63:04 Right-Sude® Univ al2018 18.0.31 RSU08101 Page 1 'CP` EADocumnetsSWrightsoft HVAC\WEINERT RESIDENCE.rup Cale = MJ8 Front Door faces: N } g Project Summary wri htsoft � Date: Mar25, 2019 AHU 2 By: QUICK CALCS, INC. 317 ST LUCIE LAW- FORT PIERCE_ FL 34946 Phone: 77246"799 Fax 772466-6796 Email: QUICKCALCS@AOLCOM For. WEINERT RESIDENCE RON RAYMOND CONSTRUCTION 17803 BRIDLE WAY, F5NTPIERCE, FL Notes: ■ ' e Weather. Fort Pierce, FL, US Winter Design Conditions Summer Design Conditions Outside db 42 OF Outside db 90 OF Inside db 70 OF Inside db 75 OF Design TD 28 OF Design TD 15 OF Dally range M Relative humidity 50 % Moisture difference 61 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 20775 Btuh Structure 18720 Btuh Ducts 4375 Btuh Ducts 3744 Btuh Central vent (0 cfm) 0 Btuh Central vent (0 cfm) 0 Btuh (none) (none) Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 25150 Btuh Use manufacturer's data n Ratelswing multiplier 0.95 Infiltration Equipment sensible load 21341 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure 2905 Btuh Ducts 1695 Btuh Central vent (0 cfm) 0 Btuh Heatingg Coolingg (none) 4600 Btuh Area (ft2) 1555 1555 Equipment latent load Volume (W) 16800 16800 Air changes hour 0.24 0.12 Equipment Total Load (Sen+Lat) 25941 Btuh Equiv. AVF (cfm) 67 34 Req. total capacity at 0.70 SH R 2.5 ton Heating Equipment Summary Cooling Equipment Summary Make Make Trane Trade Trade TRANE Model Cond 4TTR4031L1 AHRI ref Coil TEM6AOC36H31++TDR AHRI ref 7567544 Efficiency 100 EFF Efficiency 13.0 EER, 16 SEER Heating input 7.1 kW Sensible cooling 20580 Btuh Heating output 24125 Btuh Latent cooling 8820 Btuh Temperature rise 22 OF Total cooling 29400 Btuh Actual air flow 980 cfm Actual air flow 980 cfm Air flow factor 0.039 cfm/Btuh Air flow factor 0.044 cfm/Btuh Static pressure 1.00 in H2O Static pressure 1.00 in H2O Space thermostat Load sensible heat ratio 0.83 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. _ -Fk- wrightsoi!' 2019-Mar-2608:53:04 •�• ^^--^�--� RightSuite® Universal 201818.0.31 RSU08101 Page 2 A0C'P1EADocunmets\Wrlghtsoft WAMWEINERT RESIDENCE.rup Calo=MJ8 Front Door laces: N E O 01 ,3 0000000000 00 G�Oy oomaoo�o m m mo 0p0 � oom �mm m N py U � as o � W � S mm x N o000000000woo��oom000�p, nN � m N m a m N vC O OO O O O O O O O w 0 0 0 W 0 0f�10 0 0� O m NOO 00yy[[pp m 00 000gg000¢O O O�j N OOONm h U a � gy W f700�00�Q��,��00��000000 �I{m�y 11lInII GG 11^�� � IOO (� bm OO OI��my `ate � N� N �Oy� N " � S �m �` m00000�000 dO0[O te00�1000(I�O N � N '.� 0 0 m moOwoo�moc��oo��ooN�000q,�� 7ffiS o n � � N 3a W �HH wiH HO1 �`�`�mHH wi 8iH8''88H8H 8 NcodooN�w�'�Noo'P.''P,'OONOCic �o F�-�i Q o o Oq p pry HHHNHHHNNNSHH Nay HOHHHHOl6 O M «(VVV oddrod 6.�ad maddoororoc o.p000 ov�' r O CCCCGCNdNyNNNNNNN3333�� �� C0000000'OOOOOOOOOOO OOO C)O� OL V m V� w w w awe ww www www Z =0'a 15 T�i u� •� o � 2g, dtA�mm m�� c a v—�0 `A o.� rnrnrnrnrn rnOmm�rnrnrnrnarnrnm� y� �_� c �u�p ci L� C �LgFFb `"'NNNNN�NNN�-NNNNNN'�CNII�(NII�(N�JIII �-� US � �W O� b3_ m..5o � �9 b�H � � 6 K KfLLL 1T o ma = ril ��Kin� �3 a- 8 0 ++ wrightsof , Right-M Worksheet Job: AHU 1 Data: Mar25,2019 By; QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 77246&6799 Fax 772466-6796 Email: DUICKCALCSQAOL.COM 1 Room name M WIC M BATH 2 3 Eqoosed wall Room height 18.0 ft 9.3 ft heaUcool 14.9 ft 9.3 it heallcool 4 5 Room dimensions Room area 1.0 x 69.0 ft 69.0 fP 1.0 x 173.5 ft 173.5 ft' Ty Constmctim U-value Or HTM Area (w) Load Area (ft') Load number (Btuh/ft22F) (Btuh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross N/P/S Heat Cool Gass N/P/S Heat Cool 6 11 13AAccs 2 glazing, dr lcwc 2 glazing, cfr lowc 2 glazing, cir Iowa 2glazing, clr loxc 2 glazing, cIr loxc 13AA= 2giving, cir loves 2 glazing, cir loa-e 2 glazing, clr to -e 13A4ocs 2 glazing, clr lava 2 glazing, clr lowc 2 glazing, cir Iowa 2 glazing, cir low-e 2 glazing, cir lava 2 glazing, cir lave 13A-0as 2glazing, cir IIcw-em-e 2 glazing, cir lows 2 glazing, clr laic 16e-30md 0.143 0.650 0.650 0.650 0.6W 0.650 0.143 0.650 O.650 0.650 0.143 0.650 0.650 0.650 0.650 0.650 0.650 0. 0.650650 0.650 0.650 0.032 n n n n n n a a a a s s s s s s s w w w w - 4.00 O.00 0.00 18.2D 0.00 0.00 4.00 18.20 18.20 18.20 4.00 0.00 0.00 18.20 18.20 0.00 0.00 4.00 0.00 0.00 0.00 0.90 219 0.00 0.00 14.99 0.00 0.00 2.19 33.77 33.77 33.77 2.19 0.D0 0.00 14.99 14.99 0.00 0.00 219 0.00 0.00 0.00 1.60 0 0 0 0 0 0 102 0 0 0 65 0 0 0 0 0 0 0 0 0 0 69 0 0 0 0 0 0 102 0 0 0 65 0 0 0 0 0 0 0 0 0 0 69 0 0 0 0 0 0 410 0 0 0 261 0 0 0 0 0 0 0 0 0 0 62 0 0 0 0 0 0 224 0 0 0 142 0 0 0 0 0 0 0 0 0 0 110 0 0 0 0 0 0 140 6 10 0 0 0 0 0 0 0 0 0 0 0 0 174 0 a 0 0 0 0 124 0 0 0 0 0 0 0 0 0 0 0 0 0 0 174 0 0 0 0 0 0 494 109 182 0 0 0 0 0 0 0 0 0 0 0 0 155 0 0 0 0 0 0 270 203 338 0 0 0 0 0 0 0 0 0 0 0 0 278 I--G V}� C F 22A4ph 1.358 - 38.02 0.00 69 18 684 0 174 15 567 0 6 c) AEO excursion 4 6 Envelope loss/gain 1417 472 15081 1094 12 a) Infiltration 237 53 197 53 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants Q 230 0 0 0 0 Appfenceslather 0 0 Subtotal lines 6to 13) 1654 536 1706 1147 Less Wemal food 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 1651 536 1706 1147 15 Duct loads 17% 35% 285 189 17% 35% 294 404 Total room load 1939 725 2000 1551 Air required(cfm) 80 35 82 75 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed. -r' wrightsof[- 2019-Mar-26 08:53:04 RightSuite® Universa1201818.0.31 RSU08101 Page 2 Acck E:lDocunmets\Wrightsoll HVAC1WEINERT RESIDENCE.rup Colo =MJB Front Door faces: N E L d p m T � G m Ww,I W d Y Z L) fU Z) fU Mr RQ Fl a 000000000000000000000o n � o0 0� oolo0 mo �mm g� n p fJ �'� �� 000000000000000000000(�O � 00 N OOOI Vf� �m J O Zo X � a00000000000000000000go 0 o r `a � m o d E o 00000000000000000000�� o ao n F 'U O O O O O O O O O O 00 O 00 O OO O O O N O C� O m O O O O m O O V m m mN O O y IF11 L J_ O X 000000000000000000000�0 0 � � M o R x K rw "E m o o00000000000000000000�� o n yy 4� m gg $ig $m��r. mSg Si SiBgm$S81Sg 8 NoovooN �'�mNocdvocN000.=o goor000$wm�goom�oo$0000� � � � x t �O O CCCCC CddddNNNNNNN; 3.33�� glaVCi ((��t�1p�Q1(p�Q QQ1O� ,QQ QQQmy 1p�c�Q ({y�lm(� `Il66ci ii66 i61D6i3c5c5d666cscic$OM dll ��.. GCOOO OO Ci 0Ooo0ooG0000000oOr Od.q 7r3 O$ wmvw www wwvwww vww €€_€ 0 2 g m m�ry fi m m o � m 3vEl�C ppa ada qaq qmq a9pp� rya a ama qeq aacFF}} 1NNN��yy �ddMNMNNNNo] m uj m�_� B� �SS Y 5 Now T ULL 0 8m G T: O t G 000000000000000000000�0 0 � o0 00 � oo�ioo 00 vt �' �� o00000000000000000000Wo W oo W ooWoo 00 o `m of = O K 2 O O O O O O O O O O O O O O O O O O O O O W O o � N O a ,ri tm M O VE OOOOOOOOOOOOOOOOOOOOOWW O e of id 00000000000000000000000 0 0 00 00 0 00000 00 8 � �� o O O oo O 00 O O O O O o 0 o O O O o O N O W O o VI o o Vjo o Oo L O J � of W 0 = 70 K o00000000000000000000Wo 0 N LL W Oi Ip O O O O O O O O O O W W O e yl 8 n c9 �SS&S89!P F� �2888288�288888 NoodocN��mNdc v'�v_'ooNoo�.=o �� pp pp ppryry SSSNSSSNNNSSSS�E�SSSSSSWO�{ o CJ QOO OO oJCCym mOJ ejOOWWOOa{OOO OO CS ll{VVV �Co O CLCCCCYINOyyyNyyyy3333 Nq�� �� o000000dcooc000000c000.- NWNWW NNN NW WWNW WNW M HA 2 ammm� rnrnrn p�dmm P- go.E cc_ ccc_ EcCGGC cscEFE re�P�� ������ ���`� �F E3mWE� Uc ,��� arnrnrn of rnrnrnarnmrnrnrnrnrnrnW c yy NE t`� D �- N N N N N'^-�N N N N'� pGi g 8 (IIN7 CNII� IN'J YN [NIA (NIIJ �N CN�II }FC5 �59�( �FyS d SYV SO Q rJ yS 13 111111111 K KKK F u u`7 ma � in J��Kril� Fa 8m 6►r m 0 aa bno N A N pl + O�ry�^'N ryjW {� 0 Tn� IL IIy IIL <C � �~ e op py .jjlj(I oy �» P. N .7Jv p I1414)41 3yY45y adry 2� NNN+NNNNNN+NNN+NNNNN+ S y g °� bola bb olo mb loob bmlo ola - �H �3 u >;» v »> >» to�'a 1p� Ic ���o �'$ i°ilm y+y??pop pop++gog��goq��oyy0++0$0$��g0q��y0y++00 g0�g0�{0�00 gg0��y0�g0�y0�o i{i KS iS Yi Yi ii Yi�iS Y'Yio �i Yi 7S2S %i�7i Yi i52S� rm a a a m a a a a a aa�o�o» o�000No o,l+Ap oaoop O $ v (Apaop .il,��mI �1NCo $O$$$f0$$1010 $$(D V V Vb0 $eWO $$10 �i o 0�000lN.�000000$$o o`�oo$ao� a 3'� o Sn {.� + + oi5 000 �$.000000P°a 000�'o 0000� v w �• v m o O °BSc x o m u `J° �$000 rn o� � o'w 000�o00000J�o o7So osioo$ � �$ � sa x� 2 O o o�i000 Wi000000$O00000000+ a 3'� � w o�iboo Wia0000000000a 0000+ N S O ;� x op Je m+ Vm ww'000 m w A oa o�i Oooe00000b �+'oo0000000� �� xp� >W O(Ni1000 W 00 OfOO A V Op000+000000N000000000U1 9 wrightsoft Right-M Worksheet Job: AHU 2 Date: Mar25, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466.6799 Fa>c 772-46&6796 Email: OUICKCALCS®ACL.COM 1 Room name AHU 2 NOOK 2 Exposed wall 143.0 It 10.0 it 3 Room height 10.8 It 12.0 ft heat/cool 4 Roan dimensions 9.0 x 7.0 It 5 Room area 1555.0 W 63.0 fP Ty Construction U- alue Or HTM Area (fP) Load Area (ft-) Load number (Btuh/ft'--°F) (Btuh/fP) or perimeter (ft) (Btuh) a perimeter (ft) (Btuh) Heat Cool Gross WP/S Heat Cool Gross N/P/S Heat Curl 6 13A-4ocs 0.143 n 4.00 2.19 445 271 1085 61% 0 0 0 0 2 glazing, cir lowe 0.650 n 1820 14.99 24 0 437 360 0 0 0 0 2 glazing, cir lave 0.650 n 1820 14.99 12 0 218 180 0 0 0 0 2 glazing, cir low-e 0.650 a 18.2D 14.99 60 0 1092 899 0 0 0 0 11 2 glazing, cir Iowe 0.650 n 1820 14.99 48 0 874 720 0 0 0 0 2 glazing, cir love 0.650 n 18.20 11.93 30 0 546 358 0 0 0 0 13Adocs 0.143 a 4.00 219 140 140 559 305 0 0 0 0 2 glazing, cir lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cIr lowe 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-0oca 0.143 s 4.00 2.19 405 251 1004 549 84 64 256 140 2 glazing, cir lave 0.650 s 182D 14.99 6 12 109 90 0 0 0 0 2 glazing, cir ime 0.650 s 1820 14.99 20 40 364 300 20 20 364 300 2 glazing, cir lave 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 '2 glazing, cir lave 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir Iowe 0.650 s 18.20 14.99 80 160 1456 1199 0 0 0 0 2 glazing, dr lave 0.650 a 18.20 11.93 48 96 874 573 0 0 -0 0 13A4oc., 0.143 w 4.00 219 473 377 1510 825 36 36 144 79 2 glazing, cfr love 0.650 w 1820 33.77 6 0 109 203 0 0 0 0 2 glazing, clr Iowe 0.650 w 18.20 33.77 30 0 546 1013 0 0 0 0 2 glazing, cir lowe 0.650 w 1820 25.40 60 0 1092 1524 0 0 0 0 C 16B30md 0.032 - 0.90 1.60 1555 1555 1393 2488 63 63 56 101 F 22A4ph 1.356 - 38.02 0.00 1555 143 5437 0 63 16 380 0 6 c)AED excursion 487 -69 Envelope loss/gain 18704 12665 1201 550 12 a) Infiltration 2070 554 170 46 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appfianceslother 5500 1400 Subtotal (lines 6 to 13) 20775 18720 1371 1996 Less extemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 0 0 14 Subtotal 20775 18720 1371 19% 15 Duct loads 21% 20% 4375 3744 21% 20% 289 399 Total roam load 25150 22464 1660 2395 Air required (cfm) 980 980 65 104 Calculations approved byACCA to meet all requirements of Manual J 8th Ed. wrigtitsoti=e- 2010-Marv26 08:53:04 RlghtSuitee Unioersal 201818.0.31 RSU08101 Page 6 E:1DxumnetslW6ghtsoft WACiWEINERTRESIDENCE.mp Calc=M3a Front Doorfaces: N A A O,A W N pl + Ol NAWN+ P.o Oc'OC� f/1 :1 Qs 3m3 ^-. O m 6,S NNN+NNNNNN+ �Nu NNN+ H g mm mlm mlo mmo �lo ero T•75��� � �, `� NG. �. �. �. �. b.�i ¢yy¢ R'Qkgk{T R.I. �2 Mio3n'P''P' �51P ¢L R¢.429. A. v �g� HUM g g �g� ��� H��n� H ��m�� � �m iSK"i Yi 7i Yif'.+Y'Y'Yi 2Y Y'Yi�ESS iY�Y'7S Ci 5iY� Tm o � m „ FFFFmmmmmmmmmmm> » »> � �O +W 0mA�000�0AOOOA+y"m 'y 0A {m1S �y 3b°�'8"a`Sold'8$�d'^dSgS88�'^o'Id'Ic3�d'e �y ooaall000N'+>A AA�J � oy O NNOOOOOpO000P.......... m 3'^ C O ms s s m o +k p p N N O O O .029 00 O O A O O 00 O O O O 00 m s o N Z X O G% sO O+ NIOp000 IVm OA N O1010000001000000000000000 �$ i rm. �W Qn OJOOOOOlO 000000000000000 O� o f5'�oo000000000000000�oii "� 3• o 0 Z =`Bn � s o 'o f5'00000000000000oo0ooam a N x o O o� X O Z iS O10000000000000000051OWN �� :l� m)� V V1000 N 00 OQ O Ism 00100000000000000000000+ 9 G 4+ wkghtsoft' Right-M Worksheet Job: AHU2 Date: Mar25,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-466-6799 Fax 772-466-6796 Email: OUICKCALCS@AOL.COM 1 Room name FOYER DEN 3 7.0 ft 10.0 ft RoomP height12.0 ft heat/cool 12.0 It heat/cool 4 Room dimensions 7.0 x 13.0 ft 10.0 x 13.0 it 5 Room area 91.0 W 130.0 ft' Ty Construction U-value Or HTM Area (ft� Load Area (ft-) Load number (Btuh/ft? °F) (Btuh/W) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cod Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 l 13A-0ocs 0.650 n 9 84 24 96 53 112 78 171 G 2 glazing, dr lowe 0.650 n 1820 820 4. 14.99 0 0 0 0 12 0 218 210 180 2 glazing, clr lowe D.650 n 1820 14.99 12 0 218 180 0 0 0 0 2 glazing, cir lowe 0.650 n 18.20 14.99 0 0 0 0 30 0 546 450 11 2 glazing, dr lowe 0.650 n 18.20 14.99 48 0 874 720 0 0 0 0 2 glazing, cir lave 0.650 It 18.20 11.93 0 0 0 0 0 0 0 0 13A-0acs 0.143 a 4.00 19 219 0 0 0 0 0 0 0 0 2glazing, drlaves 0.650 a 0.00 0 0 0 0 0 0 0 0 ---.CGG 2 glazing, clr lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, clr lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 13A-4= 0.143 s 4.00 299 0 0 0 0 0 0 0 0 2 glazing; dr lowe 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.650 s 1820 14.99 0 0 0 0 0 0 0 0 2 glazing, clr low-e 0.650 s 1820 11.93 0 0 0 0 0 0 0 0 13A4ocs 0. w 4. 219 0 0 0 0 0 0 0 0 2 glazing, dr lave 0.650650 w 18.2020 33.77 0 0 0 0 0 0 0 0 2 glazing, cIr lave 0.650 w 18.20 33.77 0 0 0 0 0 0 0 0 2 glazing, ctr lave25 0.650 w 18.20 25.4040 0 0 0 0 0 0 0 0 C 16B30md 0.032 - 0.90 1.60 91 91 82 146 130 130 116 208 F 22A4ph 1.358 - 38.02 0.00 91 7 266 0 130 10 380 0 6 c)AED excursion -W -49 Envelope loss/gain 1536 1060 1573 960 12 a) Infiltration 119 32 170 46 b) Room xerltilaUon 0 0 0 0 13 Intemal gains: Occupants @ 230 0 0 0 0 Appliances/other 0 400 Subtotal (lines 6to 13) 1655 1092 1743 1405 Less wdemal lead 0 0 0 0 Less transfer 0 0 0 0 Redistribution -1655 -1092 654 434 14 Subtotal 0 0 2397 1839 15 Duct loads 21% 20% 0 0 21% 20% 505 368 Total room load 0 0 2902 2207 Air required (cfm) 0 0 113 96 Calculations approved bVACCA to meet all requirements of Manual J 8th Ed -+§- wrightsofe- 2079-Mar-2608:53:04 RlghtSuite® Universal 2018 18.0.31 RSU08101 Page 8 E:\Documnets\Wdghtsoft H'UAC\WEINERTRESIDENCE.mp Calc=MJ8 Front Doorfaces: N n O r OI u 00000000000000000�000�o m � ro 00 � oonoo 00 g W O � H � N O X U N O O O O O 00 O O O O O O 00 O O O) O O O m N vo O N O N O) m a � o00000000000m000mm000mm o vo gg y N �0000epp000a000000�oo��o ii��SS r N cZ i3 � mo 00 0 000�'� n� 8 N N N g U O K 00 x ❑�i �0000 0000a0000000n000'� m � o c^r ry ",c Z mo N0000c�m000000a000000c�NN o e QQ qq oo �mr�'cd$gg od�m88 m cNrddl�mo �`s c cccc c m m u m w m n m u m u3333�� o dd O d O od d d dd d d d ddo d d OO d,� �m OQ w ww www wwM www €_ € �._E �wrnrnrnmoirnrnrnmrnWarnrnrnm E C �L E E$EE L)c � _ � }Ey`mSqq CCCy L� WO Q p E d s N y D: FT > UIL V C W N� � (7 JJK41❑ �a 3-6 +}a wrightsotr Right-M) Worksheet Job: AHU2 Date: Mar25,2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466.6799 Fax 772466-6796 Email: OUICKCALCS@AOL.COM 1FR� eBATH 3 CLST 3 2d wall 6.0 ft 2.0 ft 3height 9.3 ft heaUcool 9.3 ft heat/ccd 4dimensions 9.0 x 6.0 ft 9.0 x 2.0 ft5area 54.0 ft' 18.0 W Ty Construction U-value Or HTM Area (ft� Load Area (ft') Load number (Btuh1ftMF) (Btuh/ft') or perimeter (ft) (Btuh) a perimeter (ft) (Btuh) Heat Cool Gross N/P(S Heat Cool Gross N/P/S Heat Cool fi l 0.650 R 0 0 0 0 0 0 0 0 G 2gla13A-flocs 2 glazing; cir low-e O.650 n 1820 8M 4.99 14.99 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 n 78.20 14.99 0 0 0 0 0 0 0 0 2 glazing, cir Im-e 0.650 In 18.20 14.99 0 0 0 0 0 0 0 0 11 2 glazing, ctr is v e 0.650 n 1820 14.99 0 0 0 0 0 0 0 0 2 glazing, cir Im-e 0.650 n 18.20 11.93 0 0 0 0 0 0 0 0 13A-0ocs 0.143 a 4.0 4.000 2.19 Z 0 0 0 0 0 0 0 0 2 glazing, cir Im-e 0.650 a 00 0 0 0 0 0 0 0 0 2 glazing, clr Im-e 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir lave 0.650 a 0.00 0.00 0 0 0 0 0 0 0 0 13Adocs 0.143 s 4.00 219 0 0 0 0 0 0 0 0 2 glazing,. dr Im-e 0.650 s 1820 14.99 0 0 0 0 0 0 D 0 2 glazing, dr.lowa 0.650 s 1820 14.99 0 0 0 0 0 0 0 0 2 glazing, or lows 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 0.00 0.00 0 0 0 0 0 0 0 0 2 glazing, cir low-e 0.650 s 18.20 14.99 0 0 0 0 0 0 0 0 2 glazing; cir IM-e 0.650 s 18.20 11.93 0 0 0 0 0 0 0 0 w 13A4ocs 0.143 w 4.00 2.19 56 50 199 109 19 19 74 41 2 glazing, dr low-e 0.650 w 18.20 33.77 6 0 109 203 0 0 0 0 I� 2 glazing, clr Im-a 0.650 w 18.2D 33.77 0 0 0 0 0 0 0 0 2 glazing, cir Im-e 0.650 w 1820 25.40 0 0 0 0 0 0 0 0 C 16B30md 0.032 - 0.90 1.60 54 54 48 86 18 18 16 29 F 22A4ph 1.358 - 38.02 0.00 54 6 228 0 18 2 76 0 6 c)AED excursion 71 -3 Envelope lass/gain 585 469 167 67 12 a) Infiltration 79 21 26 7 b) Roan ventilation 0 0 0 0 13 Imemal gains: Occupants Qa 230 0 0 0 0 Appliances/other 0 0 Subtotal(lines 6to 13) 664 490 193 74 Less wdemal bad 0 0 0 0 Less transfer 0 0 0 0 Redistribution 180 78 -193 -74 14 Subtotal 844 568 0 0 15 Dud loads 21% 20% 178 114 21% 20% 0 0 Total room load 1022 681 0 0 Air required (dm) 40 30 0 0 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed 2019-Mar-26 08:53:04 -"-"' RlghtSultelf Universal 2018 18.0.31 RSU08101 Page 10 E:\Documnels\Wrightsoft HVACIWEINERT RESIDENCE.mp Colo =MJB Front Door faces: N o m a' 8 A PO CO C'0� C 0 3 _ � ^� p� a � � dry np�j �m NNN +NNNNNN+NNN+NNNNN+ RAW p. �^ N (O IG fO jj�m fp ljl Opp ( qt ?a109,b� �L w 3 $gg ggngsg ggg ggggg 2 N g g€ g egg FUN � NNN0001J000000(J %i00WOtJO 004i T o A� � EFFFm v, v,m mmmmmmm>»>» p_? 2 ti x� N(,-'p. op+��pi+u1,�J'i Nt�lpp(c(pp oppp,f'a(pp lApN pO po po 800V V 104110SOtO tO �D 000(D 4f Ip IO tO tO tO N O OON00000000000000000 V 3^ O W N S K O � NlJ 01 �14)00 X• ON (O pJN OS10 f000000000000000000 �$ O_,(�, O 4 N NOIO O A O O O IWO VWi � ON OW O M O O 00 O O O O O O O O O O O O O O °� o .Nnn000000000000000000000 3,� o Loi 1 N N 9 m � A O O A O O O OO O O O O O O O O O O O 00 00 O K O xr W N 0 00 00�0o fl' oo %' ol:3c0000000ccoOccoococoo �$ � in z g v 00 00`-'00 � 00 00 � of6'000000000000000000000 9 0h aa 8 L N 2 N A w N m + • Ol NAWN+ Po O�Arr 5 gm jrl �, mo W6, mNNN+NNNNNN+NNN+N NN NN+ �T2w n (P'a'P io w 4E9. oagp_R2 gig gggg�g g�� �ggg� AkA hkAAkA � AA AkmAk D nF y?5p�pO?gqp?�gpr OgO?p�p+gO�pO�gp�C $G�gO�ppg0�g0�gp+qp�{p�C 'C�TuN i%5m �Kr 75 S Zi �Yi�i52S 2Y5 ii����7S �Yi Yi iS iu r O FFFF..........m �OwOroAWmOOiO�mAOOOAd+�q��A S N o+�u.4wiNiA00AA(�f000nli yAAAn1 n � RNA m�000(O00000000000000000 3y P W o w •• v w o tJ NN000f000000000000000000 w } o Nn x � S 6 ... g 8 00 O O T O O Om1 O O O J (JO W O N O O O+ O O OO O O O O O O O O O O OO O �ffi �i'oo+�op000+000p000000 3� to o w z �^ N O e + V �i�000��opoOpw000000000p m _ x ._, O N m m;u x 00 �1 mV V+ w N mm 1J ry N x0 p N J� T OC +NJ ^' ,p Af N N � Oxi (tl ttOO+N00 fp 00 ON V m_ 41 OONOOfO (JO OOOOt00000000000 J y m U3 m T O -AI m 0 m T r 3 i u 0 n 0 00000c�'pooa�000000000�0 � ,- �o 0o g oo�m,No [tp�� U N m x 2` o d ".� m o 000000�000�N000000000�� o 000000�000000000000000 V N e0 00 ooNoo 00 9 j N � Z. _ O X Z p O 00 O O O m O O O O O O O O O O O O O O o ro N a N� e N :.d `"� m o 000000�0000000000000oVV o pi �2 u..5m�5..5Q. m353�53�g3 a.. Qc 5.... Qm �id�i6 i6 �S�d$Tb��i6 i6 id dS �f���ib i6 gcS y:i �^ dododdddodddd Ood ddd Oo 0od 0� �� Jro O<, wzzw zvz HUH 2a2� z�z Hill2w2w ill Hill ill HUH �b6 .� ais$$vzzrz` a`$$ m 2 amm€bm of efim rnm��md rnmma c$$ cq a `—° a F�3.�E'� (gam rn'rnmm rnrnmrnrnrnarnrnN = a '$ 'rnrnrnrn NNNNN'[NIA[INJ(N�II-NNNNNN'�(NII�CNII�(N�I �- � y �°C X 'm m c Em-p m mm ca V FgC S$X�LFg9}cN5 O R0�6 W Q o� N n H y n'�+ 1'd T �S �S 111111111 ULL �-NmYN N S. wHghtsoft Right-M Worksheet Job: AHU 2 Date: Mar25, 2019 QUICK CALCS, INC. By. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772466-6799 Fac 772466-6796 Email: OUICKCALCS( AOL.COM 1 Room name WCHFN 2 F)psed wall 0 ft 3 Room height 12.0 ft heat/ccol 4 Room dimensions 10.0 x 11.0 ft 5 Room area 110.0 fit' Ty Construction U-value Or HTM Area (ft') Load Area Load number (Btuhlit'--°F) -(Btuh/ftj or perimeter (ft) (Btuh) or perimeter Heat Cool Gross N/P/S Heat Cool Gross N/P/5 Heal Cool 6 13A4acs 0. n 9 0 0 0 0 2 glazing, cir lawn 0.650650 n 1&20 820 14.4. 99 0 0 0 0 2 glazing, dr lava 0.650 n 18.20 14.99 0 0 0 0 2 glazing, dr Iowa 0.6W n 1&20 14.99 0 0 0 0 11 2glazing, clr lava 0.650 n 1820 14.99 0 0 0 0 2 glazing, dr Iowa 0.650 n 18.20 11.93 0 0 0 0 13A-4 cs 0.143 a 4.00 Z19 0 0 0 0 2 glazing, clr Iowa 0.650 a 0.00 0.00 0 0 0 0 2 glazing, clr lava 0.650 a 0.00 0.00 0 0 0 0 2 glazing, otr Iowa 0.650 a 0.00 0.00 0 0 0 0 13AAaas 0,143 s 4.00 2.19 0 0 0 0 2 glazing; dr low-e 0.650 s 1B.20 14.99 0 0 0 0 2 glazing. dr lava 0.650 s- 18.20 14.99 0 0 0 0 2 glazing, dr Iowa 0.650 s 0.00 0.00 0 a 0 0 2 glazing, dr Iowa 0.650 s 0.00 0.00 0 0 0 0 2 glazing, or Iowa 0.650 s 18.20 14.99 0 0 0 0 2 glazing, dr lava 0.650 s 18.20 11.93 0 0 0 0 Y)1 13A4ocs 0.650 w 4.20 0 0 0 0 �L---.GGG 2 glazing, dr low-e 0.650 w 18.20 3.77 33.77 0 0 0 0 2 glazing, air [ow-e 0.650 w 18.20 0 0 0 0 2 glazing, clr lave 0.650 w 78.20 25.40 25.40 0 0 0 0 C 16630md 0.032 - 0.90 1.60 110 110 99 776 F 22A4ph 1.358 - 38.02 0.00 110 0 0 0 6 c)AEO excursion -66 Envelope loss/gain 99 110 12 a) infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants @ 230 0 0 Appliances/other 1800 Subtotal (fines 6 to 13) 99 1910 Less external load 0 0 Lass transfer 0 0 Redistribution 0 0 14 Subtotal 99 1910 15 Duct loads 21% 20% 21 382 Total room lead 119 2292 Airrequired (cfm) 5 100 Calculations approved bvACCA to meet all requirements of Manual J 8th Ed rGgr.tsor�- ACCA w `RlghtSuite® Unlversa12018 18.0.37 RSU08107 2019-Mar-26 08:53:04 E:1DocumnetslWrightsoft HVAC\WEINERTRESIDENCE.mp C1I1=MJ8 Front Doorfaces: N Page 14 wrightsoft' Duct System Summary AHU1 QUICK CALCS, INC., 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 772-46Wg9 Fax 772-466-6795 Email: QUICKCALCS@AOL.COM For. WEINERT RESIDENCE, RON RAYMOND CONSTRUCTION 17803 BRIDLE WAY, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100rt 627 cfm 157 Job: Date: Mar25,2019 Fly: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 627 cfm Supply Branch Detait•Table Name Design (Stuh) Htg (cfm) CIg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BONUS ROOM C 2084 96 101 1.000 7.0 OXO VIFX 6.6 120.0 st2 BONUS ROOM -A C 2084 96 101 1.000 7.0 OX 0 VIFX 16.2 120.0 st2 LAUNDRY c 1163 3 56 1.000 6.0 Ox0 VIFx 12.3 116.0 SO M BATH h 2000 82 75 1.000 6.0 Ox 0 VIFx 11.0 115.0 SO M TOILET C 48 1 2 1.000 4.0 Ox 0 VIFx 8.8 115.0 sti Mwic h 1939 80 35 1.000 5.0 Ox0 VIFx 21.7 135.0 st4 MASTER BEDROOM C 2089 95 101 1.000 7.0 Ox0 VIFx 16.1 135.0 st4 MASTER BEDROOM -A C 2089 95 101 1.000 7.0 Ox0 VIFx 22.3 135.0 st4 STAIRS UP h 1891 78 54 1.000 6.0 Ox0 VIFx 17.0 120.0 st2 StipplyTrunlc Detail Table, Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st4 Peak AVF 270 237 1.000 612 9.0 0 x 0 VinlFlx st1 st1 Peak AVF 356 371 1.000 681 10.0 0 x 0 VinlFIX st2 Peak AVF 271 256 1.000 612 9.0 0 x 0 VinlFlx ZL 4t' wrightsoft' 2019-Mor-26 08:53:07 w'- - Righ[Suite® Lkinersal 2018 18.0.31 RSU08101 Page 1 ACCA E:\DocurmetslWrightsoft HVAC1WEINERT RESIDENCE.rup Cale =MJS Front Door faces: N Return. Branch. -Detail Table. Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR I Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening p g (in) Duct I Matl I Trunk rb2 Ox0 627 627 0 0 0 0 Ox 0 VIFx Wrightsoft- 2019-Mar-26 08:53:07 •'^' ^^•-• RlghtSuile® Universal 2018 18.0.31 RSU08101 Page 2 'C'p` EADocuwetslWrightsoft FNACIWEINERT RESIDENCE.rup Calc=MJ8 Front Door faces: N + wrightsoft` Duct System Summary AHU2 QUICK CALCS, INC. 317 ST LUCIE LANE, FORT PIERCE, FL 34946 Phone: 7724666799 Fan 772-466-6796 Email: QUICKCALCS@AOL.COM For. WEINERT RESIDENCE, RON RAYMOND CONSTRUCTION 17803 BRIDLE WAY, FORT PIERCE, FL External static pressure Pressure losses Available static pressure Supply/ return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm Job: Date: Mar25,2019 By: Cooling 1.00 in H2O 0 in H2O 1.00 in H2O 0.500 / 0.500 in H2O 1.000 in/100ft 980 cfm 243 ft Supply Branch Detal:Table Name Design (Btuh) Htg (Cfm) Clg (Cfm) Design FR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk BATH 2 h 1938 76 29 1.000 5.0 Ox 0 VI Fx 67.9 175.0 st7 BATH3 h 1022 40 30 1.000 5.0 Ox0 VIFx 50.8 155.0 st6 BEDROOM h 4533 177 120 1.000 7.0 Ox0 VIFx 64.3 175.0 st7 BEDROOM 3 C 2294 82 100 1.000 7.0 Ox 0 VIFx 50.8 155.0 st6 BEDROOM 4 h 4112 160 112 1.000 7.0 Ox 0 VIFx 56.4 155.0 st6 DEN h 2902 113 96 1.000 7.0 Ox0 VIFx 35.6 135.0 st5 DINING h 2900 113 96 1.000 7.0 Ox0 VIFx 40.0 135.0 st5 KITCHEN c 2292 5 100 1.000 7.0 Ox0 VIFx 19.7 115.0 st3 LIVING ROOM C 2201 75 96 1.000 7.0 Ox0 VIFx 37.7 135.0 st5 LIVING ROOM -A c 2201 75 96 1.000 7.0 Ox0 VIFx 34.5 135.0 st5 NOOK c 2395 65 104 1.000 7.0 Ox0 VIFx 19.7 115.0 st3 Supply TrunkDetail Table ` Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (Cfm) (Cfm) FR (fpm) (in) (in) Material Trunk st7 Peak AVF 252 149 1.000 722 8.0 0 x 0 VinlFlx st6 st6 Peak AVF 534 391 1.000 979 10.0 0 x 0 VinlFlx st5 st5 Peak AVF 911 776 1.000 988 13.0 0 x 0 VInIF1x st3 st3 Peak AVF 980 980 1.000 799 15.0 0 x 0 VInIFIX W right loft^ 2019-Mar-26 08:53:07 •"�^-••-�-RightSuiteW Universal 207818.0.31 RSU06101 A'CA EADocurrnetslWrightsoft HVACIWEINERT RESIDENCE.mp Calc=MJ8 Front Door faces: N Page 3 Name Grille Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mail Trunk rb1 Ox0 980 980 0 0 0 0 Ox 0 1 VIFx W PightSofY 2019-Mar-25 06:53:07 • -- RightSuile® Univers212018 18.0.31 RSUD8101 ACCA EADactumetsMightsoft HVAC1WEINERT RESIDENCE.rup Cale = MJ8 Front Door faces: N Page b Eo o y U = o N G � 3E U 3c Qo _c L$ LL �N cc2 c >� A�rn (L N LL U C� 7 3 L cCN a ` m m w �c0 cv �o� U � � N�a m 3� o ` c E �U U m vca N (D y .CLL