Loading...
HomeMy WebLinkAboutEVALUATION REPORTR R W Building Consultants, Inc. e B Consulting and Engineering Services for the Building Industry SCANNED C P.O. Box 230Valrico,FL33595 Pbone813.659.9197 BY Florida Board ofProfmicnal Enginens Certificate ofAuthorintiun No. 9813 �( St Lucie county Product Sub Category Manufacturer Product Name Category Therma Tru Corporation Fiber -Classic and Smooth-StarExterior Swinging Exterior Door 118lndustrial Drive Composite Edge Opaque Fiberglass Single Door Doors Assemblies Edgerton, OH 43517 InswinglOutswing Phone 419.298.1740 "Impact" Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 1D of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon F. Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Flodda Building Code (FBC) structural requirements excluding the "High Velocity Hurricane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind home debris protection this product complies with FBC Sections 1609.1.2 & R301.2.1.2 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468.4 require further engineering analysis by a licensed engineer or registered architect 6. Fiber -Classic & Smooth -Star Door panels require the use of "J" part numbers and must be stained or painted within six months of Installation 7. See drawing FL-20468.4 for size and design pressure limitations. Supporting Documents: 1. Test Report No. ETC 01-741-10701.0 ETC 01-741-10703.0 TEL 01461612 TEL01461939 2. Drawing No. No. FL-20468.4 3. Calculations Anchoring Test Standard TAS 202-94 TAB 202-94 ASTM E330-02, E331-00 ASTM E1886-05, E1996-09 ASTM E330-02, E331-00 ASTM E1886-05, E1996-09 Prepared by RW Building Consultants, Inc. (CA #9813) Prepared by RW Building Consultants, Inc. (CA #9813) 4. Quality Assurance Certificate of Participation issued by National Accreditation and Management Institute, certifying that Therma Tru Corporation is manufacturing products within a quality assurance program that complies with ISO/IEC 17020 and Guide 53. Sheet 1 of 1 Testing Laboratory ETC Laboratories ETC Laboratories Testing Evaluation Lab.,lnc. Signed bV Wendell W. Haney, P.E. Wendell W. Haney, P.E. VX Wright Testing Evaluation Lab.,lnc. V.K. Wright Signed & Sealed by Lyndon F. Schmidt, P.E. Signed & Seated by SCHAzf i`4 P�Lyndon F. Schmidt, P.E. 000 ° ��vcrV S+•, s No 43409 -o* Ct 3 e STATE OF N 0 �ea�®SS 86 NI sD e Lyndon F. Schmidt, P.E. FL PE No. 43409 12/5/2017 THERMAITRU® DOORS Fiber -Classic. & Smooth -Star. COMPOSITE EDGE OPAQUE FIBERGLASS SINGLE DOOR INSWING/OUTSWING "IMPACT" GENERAL NOTES I. This product has been evaluated and ls in compliance With the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the'High Velocity Hurricane Zone" JHVIU). 2. Product anchors shag be as Wed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used In areas requiring wind home debt protection, this product compiles Win FBC Sectors 1609.12 3 R3012.12 and does not require on Impact resistant coverNg. Thk product meets missile level V and includes Wind Zane 4 as defined in AS1M El 996 and FBC Seclions 1609.1.22 & R3012.1.2.1. 4. Far2x studfmrdng construction, anchoring of these uNh shot be the same as that shown for 2K buck masonry construction. 5. Site conditions; lhot deviate from the details of this drawing require further engineering analysis by a licensed engineer or registered architect. 6. HberClassic& SmoothSfor Door panel require the use W7 pan numbers and must be stained or painted within sx months of imtatation. 3775"NIA%. RAME WIDTH FS IN z 3 =o �ro o .41 OE Fa i c�, s a a x a n dad za SOCK DESIGN PRESSURE (PSI) DESIGN PRESSURE (PSI) CONFIGURATION HARDWARE LOCK HARDWARE INSWING OUTSW/NG POSITIVE NEGA77VE POSITIVE NEGATIVE CENMLINE x 5-1/2" Latch 3 DeadboB +60.0 -67.0 +60.0 60.0 x 12" Latch & DeadboH +67.0 -67.0 +67.0 -67.0 x N/A MuNipolnt +50.0 .50.0 +50.0 -50.0 See Sheet 3 for Hardware Specifications a: FL-20466.4 EXTERIOR COMPOSITE HINGESRLE CAP (ENGINEERED WOOD) INTERIOR (ENGINEERED WOOD) 1 HORIZONTAL CROSS SECTION 2 36.0' MAX. 35.013" MAX. EXTERIOR 0.406" 0.7, OMPOSITE CAP COMPOSITE HINGE STILE CAP (ENGINEERED WOOD) INTERIOR 2 HORIZONTAL CROSS SECTION 2 35.3133'MAX. PAN 2 D R DOOR�~�OR NEZ D1H PANWDIHF �E m 5 o cd 0 m 0 O » 0 O O » O 0 O » 3 i h D D D 40 DOOR PANEL BOOK 41 DOOR PANEL Hyb6tl O. 42 DOOR PANEL UT O. (ENGINEERED WOOD) \\p....•. •rlll `�9�. ••<i`�aa� m Z Komi DMPOSITE CAP gE zm o a y 9 0 o n na_ ma: TOP RAIL fro (COMPOSITE/ENGINEERED d WOOD) a o 0 uo a > >m FOAM CORE (POLYURETHANE- zgg ' 1.9 PCF MIN.J .3 ¢ C ego INTERIOR EXTERIOR INTERIOR EXTERIOR 3 VERTICAL CROSS SECTION �1 VERTICAL CROSS SECTION wre Da 02/16 N.T.S. 2 2 owo. on JK m cm W. LFS ; om"g No: m FL-2046E.4 0 sxcn 2 or -IL " CHART SCHLAGE KNOB: F51 DEADBOLT. 860 KNOB: SIGNATURESERIES KWIKSET DEADBOLT: SIGNATURE SERIES(980) HOPPE MULDPOINT:MPDGART (rHERMA-TRU) (3 pt. Manual Tongue) Fiber-Classic/Smooth-Star Door Panel Options Products approved include at embossed panel doors and 2 panel recessed panel doors. Similar opaque panel con0gurallons are allowed. Panels shown are for Illustration and are representative only. i F ear FL-20468.4 \\Illll111/fff aM D m EWN 90_- „y m66 b4 CZ ]LL V] 40 41 42 7 1� EXTERIOR INTERIOR 1.15"MIN. �o VER17CAL CROSS SECTION _ EMB'(TMP') w w iW E ��Shown w/D(DUCK OutsMng shown(InyMng similar) R 6 io C O0 U L C o � m ° 0.15CHIP) O.I (IYP) (IYPJ rypj � � L o u 1 mF m •. oil D ..o p n�ry w Q 7 huh o INTERIOR INTE IOR o w n 2, n moo 0 oek' oz� a¢� i 223 24 6KIERIOR EKIEIOOR o 40 41 42 40 41 42 27 are OBry02 16 ? 1-1/4°MIN. L 29 I-1/4°MW. scut 6 N.T.S. _ EMB.(1YP.) 1 EMB. (TYP.) own or: JK m' 2 HORIZONTAL CROSS SECTION HORIZONTAL CROSS SECTION cex. V. LFS s Q Shown w 1K uc: �hown w/ BUCKw/ BUCK annuwo No.: p Ouwv gshown (Inswing slMlar) OutsMng shown(Inswing simV) '^ FL-20468.4 0 s u 4 of 11 — O \\11111111/�I� A i pip 1 1 PI 1X Buckto secured C $ a mmom masonry hyothers a x u z mt{i Rm. 9d=oa =.6 7 T 11a EXTERIOR INTERIOR4 'm ­T1 ¢Y VERTICAL CROSS SECTION $ Shown wl IX sub -buck Outswing shown (InsvAng slmilar) c� o zo C 'amU �m J 1 S °4 O UFLL 00" 2^ p 7 NON m Z G INTERIOR INTERIOR 8 we Cu om� ° o � S$� �w 23 24 IXfERIOR FXIkRIOR L. 4 ^ = o 40 41 42 40 41 42 27 A I-1/4•MIN. 29 T 1-1/4"MIN. Dora 08102116 _ EMB, j1YP.) EMB. (IYP.) scua N.T.S. %22 HORIZONZAL CROSS SECTION HORIZONTAL CROSS SECTIONCROSS SECTION wvc. w. JK m cxx. er: LFS 3 �3hown wl ix sub- uc Oulswing shown Ilrcwing slmilar) $ S ownwl lA sub- ock Oulsvdng shown )IMwnng similar) m FL-20468.4 0 s116.T S aG I I N Q MDiil02 /�('////.���j INTERIOR 1 VERTICAL CROSS SECTION 6 Shown Direct to Mariam Outswig only w/4-9116 Jamb INTERIOR M 1-1/4'MIN. EMB. PP.) is MAX. DIRECT TO MASONRY MAX. DESIGN PRESSURE: w/ STANDARD STRIKE= 1:47 PSF w/SECURRY STRIKE= t55PSF i V I E%IERIOR g I I, I EMB. ITYP.J HORIZONTAL CROSS SECTION HORIZONTAL CROSS SECTION 6 Shown Direct to Masonry 6 Shown Direct to Mason Outswing only w/4-9/16'Jamb OU11=1 gect to 4-9/16 Jamb EXTERIOR _W M1101 n VERTICAL CROSS SECTION �Outswl gironlyw/6-9/16 jambgironlyw/ 6-9/16 Jamb �r5-'� HORIZONTAL CROSS SECTION �--� Ouls winDirect only W/6--9/16 Jamb 1 S' MAX. O I Z 3i n i 64i� Yys � ...... `O f a `gym "..0���` h �'✓ 0e�cz �zu _�S � m°c 9 NS ,aLnm 4 4 O� F W CJ o n b� >r �o g in 0 �m 0 G o o0 � o x� � � /�-61 HORIZONTAL CROSS SECTION vnn. an JK e 6 Shown Direst to Masonry MAW;; LFS o Outswrin only w/6-9/16'Jamb ow>nm , FL-20468.4 e .w 6 -, II E Notes: L SDI Item #'s17,18,32,34,35,36,37,38&39 are attached to jambsw/(3)#8X2-1/2'pthscrews at each end �$ A � �:• •. vQ '•'�' � SH Item Vs 16&33 are Ghuched to jambsw/(2)ff8%2-1/2'pth screen at each end. m Sill Item 0151s attached folambs afiliring l2j#10X 2'pph SMS at each end. zW, z° 64•OY dm • INTERIOR EXTERIOR INTERIOR EXTERIOR ///q f Itpi p Suu N m n zomo �. 8q.:z e z orti v oa l° 38 39 32 33 34 35 36 37 #4 mno ° � oz E SEE NOTE 1 E SEE NOTE 1\ 9 n po ox m� Fmk �1 VERTICAL CROSS SECTION 2 VERTICAL CROSS SECTION 7 Inswing Sill 7 Inswing Sill Y YY EXTERIOR INTERIOR EXTERIOR � INTERIOR SEE NOTE I 3 VERTICAL CROSS SECTION 7 OWsw(ng Si0 4 VERTICAL CROSS SECTION °x+FIL 7 Public Access Sill F7-20468.4 a SW ] OF i1 a arvi uNvnneNeO owo�ine -Nrn s taz £t9- 'ON gd�U04d SNOISIA3a ON L6t6•tt99A'0TZ N euoVd s9s££ v 'eaNlen 'o£z xea •0•eJNI8OH9NV 3WYtli OM/ NOOK m si .{ r'SWV=SKO0 ONIMIng :AlHW39S/ aO i d aonat—ss 7otoeld ItlNO%�L�4,� .— -d o 1O wiw� - � ao3nas Ot :xe r.roa..e .w•Wnew aanaoaa a � a � LIMZ/11 = fiOCEV'eN =�/ �rrnnuna\`` NIA x � an Z _ < p� O O Y _ LLJ L W$y C 4 J� 1'dAll'p'O Z %'C O ¢ � V La y ^ Q Y V m N Y � 0 ac$ O C r--'I'dul,r y�.� IdAU po I 'XVW SHt Z k 0 Q U y � i Z Q U m of A tl0 ON JVf JBd LIOZ m Y!9 Cll 31Mdn Lt Lt L t NOLLVGON l3NYd O359J3a ONV ar 'J noaavda aov a st m Z 9'8 � Y96'B9Y0E-V W'3tlNN-(LIU() B9C4t 1f156uHP+0 -Jl>l6�dlucJ-Aedui[ R Jf 1LU(ieM89ro2-lilA��V AeW W QOVW -YLN3MMU3e �ulau++Vl\9uap�\:a OZ C 186 'ON YO 3ded I SNOISIA3a L648'699'9l8 !'-N ...11 00 < -I A 511V13a 38YMoaYN 9688£ V 'oaMloA 'OCL Om 'O'd A/'y f/1 m 91NYLlf19N0D 8N10'11nB„lLQ7A18W35SV tl0 WYd N FE y �d �e9,6,� sss'e oueovcdj ilOf�ILaG-�vW�t�f�1L81! o z �• vil:'C•v+ m O�i fe waeue nwawraaa -Mnaoad a 8 E o �_LU6VLL yy 6n667'9NOd °r�nmuua� J1 �' n o a C Y o J 5 N Y Y O U U Orc Y mO m m GO Z 0 �ISI{I AV �dl'8V 1E'SZ �o pxa F ��— uu4oml� P' to F ym m m �zo aooa aooa aooa doiwoaidsZrtt:TamAWinTCfSUWLnToMXWtn �{ HI'dAl1,U'SLPdAl15SZ1'dlll �D'SL EWY�dO a000NOOOaooadOlwONgZt'S MOOSNODSMOOS 'SSZNkd SO('dm.SSZ z x z N =a � Ho � 49't sl .eEw = zt � o� a ® °z O� =oo z In VN �O HO � c Way m Yh ya i o 6S m� 00 xao p2 u �u6 ON �o s — Rog Boa � •• m � 5 N � G a Y 0 5 o a o om O O m o 0 12 m o O N N it E S 2 x u Ox G O m m O z m m z > > z IU-. r x �0 x� 5 AB 31tl0 ON Nf 98d LWZ 03 419 Ol 31Y6dn LI L{ L l NOLLYlON l3NYd a359J3N OM/ ar ro 'o .z rs noeovaa aoY a sl of z L R.. .-5 4 .''i L .icy h t T f. 1 II II IIIII/'r•• IIII O```` �' zcl MIT INSWING IHRESHOID S 8 N /l INSWING THRESHOLD 37 WOOD JAMB Wv4eg Rasie Composite Adjustable M MIT Imxing gave Faetl7-I/TSi➢ 1 8 c ? m gN 9d 456ETa- I � 68T � c ^ C & d K O INSWING THRESHOLD INSWING THRESHOLD OORWING THRESHOLD 33 Imvriag Basic Faed Sill 38 Inswing Composite Adjuslobla SR 76 Composite SN J 4S6° 7•--III— 6.77" o � 0 o o � INSWING THRESHON InsvnrSq Modemm CWnole SR l3fS /'IINSWINGTNFESHOLO ``J UuINg Basic Compose A C M t c a)le SN 17 GIIISWING THRESHOLD zD Composite/Aluminum SN ci 6.75' �a6 0 Pn � 6.0' ? 6.75' J o h oyyJ a fig, o o g K vellD INSWING iHRESH010 o D 3 Wwng Modemte CGmotesm ado 2 po �10URWING THRESHLle/AWmhumOLD PUBNC ACCESS IHRESHON ComS➢ o ^r ; F_•-5.75� 15 IDie�mal eieap a ; Ma H ^ Z L L mm 08102116 s N.T.S. I 0 0 0 j�j vva M JK E INSWING 7NFESNOID {-� 1.79" r-1.9T' 1.06" �-I I rmc m LFS 3 36 inswing gaslc HnMd S3/rsin ° °IUtNNO Na.: N d B SWEEP 9 SWEEP 10 SWEEP o FL-20465.4 n \\ Jam\ Nj''i BILL OF MATERIALS BILL iv*gE =0iy� N'.,7 z zaiR 4)�0 e n zomd 8 0z S 9 "2� Ej `o i o�W 3u o o 0 S $ S W W O m o 0 a Y YY �m da� 0 azo n NdN �a6 z 2 0 CO ANCHOR NOTES: the �_ I. Concrete anchorlocalions of the comers Crete edge distance to mortorjotnls. maybe adjusted to malnlatn Mn. gmg Pl, a: 2. Concreteanchorioc flonsnotedas MAX. ONCENTER'mustbeadjustedto orck maintain the min. edge distance to mortarjoInts, additional concrete onchors a maybe mqutred to ensure the MAX ON CENTER" dimension are not exceeded. $ a i z 3. Concrete anchor table: o n� z MM 08102116 sauc N.T.S. RwR. m: JK m cxx. en. LFS ? oWNG No, ° I. Maintain a minimum 5/e edge distance, rand distance, & 1 o.c. spacing of FL-20466.4 ° "ad screws to prevent the splitting of wood. 51¢ct i f Or j 1 O OF MATERIALS ITEM # DESCRIPTION MATERIAL 11EM A DESCRIPTION MATERIAL A 1XBUCK(SG>=0.42) WOOD 25 #8x2-1/2"PFH WOOD SCREW STEEL B 2X BUCK (SG>= 0.42J WOOD 26 #8 x 5/8"PFH WOOD SCREW STEEL C 1(4"MAX. SHIM SPACE - 27 LATCH STRIKE PLATE STEEL D 1 /4" X 2-3/4" PFH ELCO OR ITW CONCRETE SCREW STEEL 28 DEADBOLT STRIKE PLATE (STANDARD) STEEL E MASONRY-3,000 PSI MIN. CONCRETE CONFORMING TO ACI 301 OR HOLLOW BLOCK CONFORMING TO ASTM C90 CONCRETE 28A DEADBOLT SUB STRIKE PLATE STEEL 288 DEADBOLT STRIKE PLATE (SECURITY) STEEL G 3/16"X3-1(4"ITW CONCRETE SCREW STEEL 29 4''X4"HINGE STEEL J 1/4" X 3-3/4"PFH ELCO OR ITW CONCRETE SCREW STEEL 30 LATCH & DEADBOLT STRIKE PLATE (TONGUE SYSTEM) ALUM/COMP L #lOX2-1/2'PFH WOOD SCREW (1.15'MIN.EMBEDMENT) STEEL 31 MULTIPOINT STRIKE PLATE (TONGUESYSTEM) ALUM/COMP M 3/16"X2-1/4"RW CONCRETE SCREW STEEL 32 INSWING THRESHOLD ALUM/COMP N 3/16"X2-3/4"ITW CONCRETE SCREW STEEL 33 INSWING THRESHOLD ALUM/COMP 1 JAMB (FINGER JOINT PINE) WOOD 34 INSWING THRESHOLD ALUM/COMP d WEATHERSTRIP (MEDIUM REACH) FOAM 35 INSWING THRESHOLD ALUM/COMP 7 WEATHERSTRIP (LONG REACH) FOAM 36 INSWING THRESHOLD ALUM/COMP 8 SWEEP VINYL 37 INSWING THRESHOLD ALUMJCOMP 9 SWEEP (USE wl MODERATE CLIMATE THRESHOLD) VINYL 38 INSWING THRESHOLD ALUM/COMP 10 SWEEP (USE w/PUBLIC ACCESS THRESHOLD) VINYL 39 INSWING THRESHOLD ALUM/COMP 15 PUBLIC ACCESS THRESHOLD ALUM 40 DOOR PANEL (800K) 16 OUTSWING THRESHOLD ALUMlCOMP 41 DOOR PANEL (HYBRID) 17 OUTSWING THRESHOLD ALUNI/COMP 42 DOOR PANEL (UI) 18 OUT$WINGTHRESHOLD ALUM/COMP 22 #8x3/4'PFH WOOD SCREW STEEL 23 #IOx3/4"PFH WOOD SCREW STEEL 24 #10 x 1" PFH WOOD SCREW STEEL ANCHOR ANCHOR "MIN. hUN. CLEARANCE MIN CLEARANCE 'SRE EMBEOMENY 70 MASONRY' „TO ADJACENT --'EDGE ANCHOR ITW / TAPCON ELCO 1/4° 1.1/4" 1" 4" ULiRACON HW • 3/id" 1.1/4° AS SHOWN T-1/2" TAPCON WOOD SCREW IN57ALIATION NOTES: R W R W Building Consultants, Inc. BConsulting and Engineering Services for the Building Industry C P.O. Box 230 Valrico, FL 33595 Phone 813.659.9197 Florida Board of Professional Engineers Certificate ofAuthorimtion No. 9813 SCANNED BY St. Lucie County Product Category Sub Category Manufacturer Product Name Swinging Therma Tru Corporation Fiber -Classic and Smoat"tar Exterior Exterior Door 1181ntlustrial Drive Composite Edge Glazed Fiberglass Double Door Doors Assemblies Edgerton, OH 43517 9 w/ or w/out Sidelftes Phone 419.298.1740 Inswing/Outswing "ImpacC Scope: This is a Product Evaluation report issued by R W Building Consultants, Inc. and Lyndon F. Schmidt, P.E. for Therma Tru Corporation based on Rule Chapter No. 61 G20-3, Method 10 of the State of Florida Product Approval, Department of Business & Professional Regulation. RW Building Consultants and Lyndon R Schmidt, P.E. do not have nor will acquire financial interest in the company manufacturing or distributing the product or in any other entity involved in the approval process of the product named herein. Limitations: 1. This product has been evaluated and is in compliance with the 6th Edition (2017) Florida Building Code (FBC) structural requirements excluding the "High Velocity Hunicane Zone" (HVHZ). 2. Product anchors shall be as listed and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used in areas requiring wind borne debris protection this product complies with FBC Sections 1609.12 & R301.212 and does not require an impact resistant covering. This product meets missile level "D" and includes Wind Zone 4 as defined in ASTM E1996 and FBC Sections 1609.1.2.2 & R3012.1.2.1. 4. For 2x stud framing construction, anchoring of these units shall be the same as that shown for 2x buck masonry construction. 5. Site conditions that deviate from the details of drawing FL-20468-12 require further engineering analysis by a licensed engineer or registered architect. 6. Fiber -Classic & Smooth -Star Door and Sidelite panels require the use of "J" part numbers and must be stained or painted within sit months of installation 7. See drawing FL-20468.12 for size and design pressure limitations. Supporting Documents: 1. Test Report No. TEL 01460274 TEL 01460131 TEL 06-0831-1 TEL 01461612 TEL 01461939 Test Standard ASTM El 886-05, E1996-05 ASTM E330-02, E331-00 ASTM E1886-02, E1996-02 ASTM E330-02, E331-00 AAMANVDMA/CSA101/I.S.2/A440-05 ASTM E1886-02, E1996-02 ASTM E1886-05, E1996-09 ASTM E330-02, E331-00 ASTM E330-02, E331-00 ASTM E1886-05, E1996-09 Testing Laboratory Signed by Testing Evaluation Lab.,lnc. V.K. Wright Testing Evaluation Lab.,lno. V.K. Wright Testing Evaluation Lati-Inc. V.K Wright Testing Evaluation Lab.,lnc. V.K Wright Testing Evaluation Lab.,lnc V.K. Wright 2. Miami Dade NOA Materials Testing 16-1117.01 Butaclte° PVB IMedayer(Kuraray) 17-0712.05 Saflex® PVB Irderlayer (Eastman Chemical Company) 3. Drawing No. Prepared by e®e® c�s�F;U/ ®gso Stoned &Sealed by No. FL-20468.12 RW Building Consultants. Inc. (CA #9813) o%% �:_•' "° CAB®m Lyndon F. Schmidt, P.E. 4. Calculations Prepared by�N�F.•', moo® $rgned &Sealed by Anchoring RW Building Consultants, Inc. (CA#9813) 9 8 No 43409 'o don F. Schmidt, P.E. 5. Quality Assurance Certificate of Participation issued by National Accreditation and Managemea r Institute, certifying that Thermo Tru Corporation is manufacturing products e- y) ° STATE D o within a quality assurance program that complies with ISO/IEC 17020 and a O •'. '^ Guide 53. Lyndon F. Schmidt. P.E. ed`aps tie raa6 t�6®� FL PE No. 43409 Sheet 1 of 1 12/14/2017 THERMAITRU® DOORS Fiber -Classic. & Smooth -Stara COMPOSITE EDGE GLAZED FIBERGLASS DOUBLE DOOR wl or wlout SIDELITES INSWING/OUTSWING "IMPACT' GENERAL NOTES 1. This product has been evaluated and is in compliance with the 6th Edition(20171 Florida Building Cade T11C( structural requirements excluding the "High Velocity Hurricane Zone"(HVHZ(. 2. Product anchors shall be as ruled and spaced as shown on details. Anchor embedment to base material shall be beyond wall dressing or stucco. 3. When used In areas requiring wind bome debris protection this product complies with FBC Sections 1609.1.2 & R30121.2 and does not require an Impact reemant covering. This product meets missile level'U'and Includes Wind Zane 4 as defined in ASTM El976 and FBC Sections 1609.1.2.2 & R301.2.1.2.1. 4. For 2xstud framing construction, anchoring of these units shall be the some as that shown fcr2r buck masonry construction. 5. Site conditions that deviate from the details of INS drawings require further engineering analysis by a Itcemed engineer or registered architect. 6. Fiber-Classic&Smooth-Star Door&SldeOte panels require the use of"J"pad numbers and must be stained or pointed within six months of installation. 74.75" MAX. FRAME WIDTH --�{ 3 4 o� °o i X X �m e a e a� , 151.25 MAX. FRAME WIDTH 37.S MAXFRAME WIDTH . 074.75MAX, FRAME WIDTH t7 G z O z ?g O X X p o Lit I i CONFIGURATION DESIGN PRESSURE (PSI) INSWING DESIGN PRESSURE (PSF) I OUFSWING POSITIVE NEGATIVE I POSITIVE NEGATIVE xx, Ono +50.0 -50.0 +50.0 50.0 See Sheet 4 for Hardware Specifications m: FL-20468.12 95,25 MAX. DOOR PANEL HEIGHT i 952F MAX DOOR PANEL HEIGHT EL HEIG 95.06"MAX. DOOR PAN HT X 0 0 ---I �Ss 4 xO 0 0 0 A 0 0 0 ill Ow 0. 0-894- 0 s o K 00 022 A T No. 43409 1112917S I I PRODUCT: THFRUA-Mfl son Lyndon +111 F7BERGLASS DOOR No. %% lulfbIll ADD OEADBOLT 5 -1/2- 0. C. BUILDING CONSULTANTS, Lplto o o, 2 AND RECESSED PANEL UPDATE TO —6th ED (2017) MC I JK I P.O. So. 230. Vold.. FL- 33595 TTO- m� 19 DOOR PANEL DETAILS P hone No, 813.659.9197 REVISIONS MPE CA No. 9813 Conlc A. —I.. ..... .. I... R\Cf1en[s\ll�emu TN PERMANENM- FlonEa PrMv[l AppmvalAFDhbW WB00.TT FC 55 Mpatt-CPTPoSite\C- Drawings\iL 20E68 (LOt7) - CURRENgFL-N068.10-13 Ewg.38 9575 MA7(. PANEL H9GHf 0 �7.T— m e 0 0 m� m� x O A Z n I0 o A N N H m Q O Z 00 0 om -aa Tad 00H o° =� 9 m m � � o A N m I I p I I f---f—OST .081 - ----{ Z 0 `�.yr. rua 43A09 71/29/17==� 1, t< �i PRODUCT: oewmub Pnpoiaa W. THERMA—TRU Lyndon F. SehmlM ti z m FIBERGLASS DOOR P.E. No. 43 9 N u p�/ ........ �O a P z oMNO 10 1s DPADBotr 5-1 2. 0CJKATII1.1110,AND RECESSED PANEL NOTATION PARF OR ASSEMBLY: BUILDING CONSULTANTSI�F] O 1] UPDATE TO 5th EO 201] FBL JK P.O. Bon 230, V91Nee, FL 33585 DATE BY SIDELITE PANEL DETAILS phone No.: 813.659.9197 REVISIONS MPE CA No. 9813 ® 2016 R.W. BxILCING Coxau,.i�v�a Ixe. 3 3 3 5 5 d 7 7 4 T 7 4 O d $ i 7 � D 4 I 2 3 4 SEE HARDWARE CHART 8 8 8 T vv� AMI it 4 5 O 5 O 7 O 6 5 D 4 D 4 s 2 3 8 SEE HARDWARE CHART 5 d B B 8 B B II � �� IIIIIII IIIIIII �� Irk i—� � Fiber-Clossic/SM00fb-Star Door Panel Opflons Products approved include all embossed panel doors and 2 panel recessed panel doors. Shllar glazed panel configurations are allowed. Panels shown are forillusiration and cm representative only. U• JAR d�( �o IfobdE Ni �g '.�''•. ...N 'O '\wrr1 ��,` Ih onmz �q a $ 9°w dca au: mdnT KNOB: FS1 SCHLAGE DEADBOLT: B60 KWIKSEL KNOB: SIGNATURE SERIES DEADBOLT: SIGNATURE SERIES(980) HOPPE MULTIPOINT: MPDGART (THERMA•TRU) (3 pt. Manual Tongue) aE: 08102 16 _ wE: N.T.S. _ e : JK u, m LFS ; uwwo x°.: rc FL-20468.12 OU g OF� e 4 0 rrrlilrinnir! A Novo 1' v• 5 HORIZONTAL CROSS SECTION 5 Ouhwngs own Ins ngsm or I WMIN. INTERIOR EXTERIOR �21 HORIZONTAL CROSS SECTION 5 Ouswingshown Inw+ing slmlar (� HORIZONTAL CROSS SECTION 5 Ouswmgshown 1rs gslmilar Notes: 11. Sdelite assemblVscrews located C from each end and 6 mare screws equally spaced between 18 screws total per side jamb). 2. Sidefite assembly screws located 3' Bom each end & at centerline (3 screws along head jamb). U o \ J U EXTERIOR WA INTERIOR o VERTICAL CROSS SECTION 5 Oatswing strum linsmng similar) v%V�JNT�ERIOR —L SE c 4 VERTICAL CROSS SECTION 5 Oulswing shown (Inswing similar) s. er: JK x. ar: LFS nNxo xo.: FL-20468.12 ra _L or 14 Notes 11. Sidelite assembly screws located 6" from each end and 6 more screws equally spaced between (8 screws total per side lamb). 2. Sideliite assembly screws located X from each end & at centerule 13 screws along head lamb). INTERIOR EXTERIOR 1-1KWN. v 4� 4T 42 —^r EMS. 1TYP.l �11 HORIZONTAL CROSS SECTION �1 HORIZONTAL CROSS SECTION 6 Shnwnw/IXsul>buck 6 Shr w/Ix su ucb� Outswing sham(Inswing similad Ouhwing shown(irnwing similar) EXTERIOR ZNZA INTERIOR 3 VERTICAL CROSS SECTION d) Sham shown llbnmingslmilad ss a ee. p. pe 0 ME EXTERIOR 1% INTERIOR VERTICAL CROSS SECTION d Shownwf I SutrbucR Oulswing shown (Inswing simlar) �x .Us &* j$ T :gi bQ;•�0=�' /��� II II111 \\\\ CO- 8 zE za ;SS 9 CA �Us y LL `dn� NEMMMIE _a 0 ry -z Boa/o2 tfi a.m JK a: LFS ; FL-20466.12 � ver 6 or 14 g 1,S I.26' MIN WMIOR INIERIOR eVERTICAL CROSS SECTION 7 Shown Direct to Man. Outsmngg ontyw/ 4-9/16'jamb Double OoorOnly (N/Aw/Sldelites) Notes: I. SideSideflle assembly saews located 6" Irom each end plus 6 more equally spaced between (8 saem total per side Iamb). 2. S-1del a assembly saem located W from each end 8 at centerline (3 screws along head jamb). C rn � 1 z h � � INTERIOR EMU. (TYP.) V I .t°I DTRIOR 1 HORIZONTAL CROSS SECTION 7 Shown Drect to Masonry, Outswing only w/ 4-9/16 Iamb Double Door Only (N/A w/ Sldelites) DMIRIOR _W INTERIOR VERTICAL CROSS SECTION Z OuhwlwingonNw/69//16jamb INTERIOR 1-1/4"MIN. E% RIOR EMU. (IYP.) 4 HORIZONTAL CROSS SECTION T Oulswinglontytwo 6-9/16 jamb MAX. _U:s�i V T tjsZayA 2 Ns, by \j, : ^6u *MERIORILNTRIOR C3 :te am i i� 6eVERTICAL CROSS SECTION o T Shown Direct to Masonry Outswing ontyw/6-9/16 jamb �$ �w gym J w o0 � �z m U m0 SC 0 INTERIOR n U s�= 4. 0 :1R111 25 u� E "z °u SEE NOIEI I -I /4"MIN. MM. 8102116 FMB.1.1 sole N.T.S. 2 HORIZONTAL CROSS SECTION °N'0 m. JK ° 7 Shown Drect to Masonry cxN. W. LFS a OuWngantyw/6-9/16'jamb oM,mx°No.: a FL-20468.12 °n sxsa 7 °R 1a Nolen 1. $91tem 4's 17.18. 32. 34, 35. 36.37. 38 & 39 am attached to jambs w/ (3) 08 X 2-1/T plh screws at each and. Sa Item It's 16 & 33 are attached to lambs w/ (2) 88X 2-11T pthscram at each end. SRI Item 915 is attached to lambs utRing (2( 010 X 2' pph screws at each end. 2. Sidefile assembry screws located 3 fmm each end & atcenterrtne 13 screws along 0). INTERIOR -rl7)&,77(- EXTERIOR INTERIOR -p7A= EXTERIOR SEE NOTE I SEE NOTE n e id D za D E� E� 1 VERTICAL CROSS SECTION m 2 VERTICAL CROSS SECTION Inswing SO w 8 Iruw0i95a ,�\.�_,_,� INTERIOR �RIOR EXTERIOR �!//}C//,I INTERIOR sEE NoiE2 25 ��j�,��-�1`5�D�) - - - - 7- a .•.. ••e. I 4 VERTICAL CROSS SECTION I; PabR. ACCBSi5R e @ m � _ _VERTICAL CROSS SECI1ON- ^'� B Inswlnlnswing Slll EXTERIOR 1 42 HEI INTERIOR e, D 3 VERTICAL CROSS SECTION R Outswing sill EXTERIOR -F7/%;� INTERIOR n•. D 6 VERTICAL CROSS SECTION R Oulswing Sill RO 2x0 UK o � = Z :o- 08102116 ws: N.T.S. Is. M JK Tx. er: LFS u uwwo xo.: � FL-20468. 12 n 1M 8 or 14 a M'tl9 ZQ £L86 'eN Yo 3dad SNOISIA3a G6L6-6a9'£L9 L'oN em4d n v 969££ V 'COPPA -O£2 •pa 'O'd� ma0HONV NONE '^ 1lnSN00 ONIQ11na (J AlalY35Sb 80 ll d ,091D%p—Gi ivlw4 5R'd a.-PIA'd 8 00 5SV1..90BIJ 2?:' aQ"a �J fe�eevd .,,,ewe>oa �ianaoad a € " 5 i acu�eziu _ ' x 606EC ON ---------------- --------------- ----------------- ------------------ zo a d a = � < O o � --------------------------------------- } L V' Z � Q I I V m k N i= �'XVW S'Bl i .- a ------------------- ---- X --------------------------------------- X o E AB 31tlU ON Nf Jad GL02 03 N9 Ol 31tlOd0 Ll Gl G t N04tl10N l3NYd 03553J3a ONb >rr.z t-s npaav3a apv a/sL oL z ff6'6^`A'iL'pL99Wi�li\1N3NtlN-4LOL78950i1!\s6wmup-p\aslsotlwop-petlu6S5 JJ lltl08fA 99602�1iLsla^o+ddtl A�Pwd eOVON � WN3NtlWtl3d wl awuyy\ssuaiDVa DIRECTTj MASONASTRAGAL 3,.mP.'�TITY1 IIII I I I I I L 2X BUCK J IXBUCKII HEAD &JAMBS I (TYP-) DIRECT TO M MASONRY N JAMBS (ttP ) — I I II I I SILL II I �1 II I I I IIII I xx DIRECT TO D MASONRY HEAD ITYP.1 gyp.) BU( HY DIRECTTC MASONW R' (ff ( -c O FRA ITYi 13168K2-1/T' ' PFH WS JAMB TO HEAD DETAIL (TYP.1 mp I 3-p.) m.P.l T' (IYP.) 3' (rrP.l 84„ 7 pYP.I I I I I I LIII I I I I I L 2X BUCK I I I I I K — — J IX BUCK I — Ii — LI HEAD 8 JAMBS _ I I FYN II I I I I — L JAMBS (TYP ) I I THIRD MULLION _ I mP.) AE — I I I — .( — I I I I — SILL (TY'•1 I I I IIII I I I I I I I -� FRAME ANCHORING •��• hry•Ip1 ST`�S m�nw � zdm`d p � V N •• � g E imzo < <w —L 9p�n 54 maa� 2z �o fry o Iw cti U o 0 a � Vim y IZI L 01- 08 02116 AN: N.T.S. M Br. JK u IN. Br: LFS 3 MWNO NO.: ° FL-20468.72 c lw 10 OF 14 6 vNl 6yNtlyln6No') EINIOlIM19 'M'a 9lOE CLOG -oN v0 3ded SNOISIh3a L6 LG'669'£48 gory auoyd l.B 31V0 ON S65££ l 'OaNlop '0£L zo6 'O'd/1/i n�d�0 3aYM0atlH pf 09! LtOZ 03 419 Ol 31VOd0 L( Gl G L \ I/1 J sd SlNV1'IO6N00 ONIMIn9 y +AeW3 a0 iWd NOLLVICN l3NVd 039£303a ONV �- f° o � �11111 IVN0� /G' 609£b 'eN 3'd aooa sscnsa3e� Nf '0 '0 .2 L-S 1108aVl0 OOV GI St OL Z o Z i N ., ���...�.� � ivlw4as 'tl ve0u.(l (Iill-1M1Ya3fi1 t' Al do=nnn O � EGG va�d vy,awlw6 �l�n6oaa a � g � $ ` W fi06£6 ON d'8Nei n gm 'GG/1111111\\\\ m ^ e W n x ® ^ Y rc O w N tu a c� o mo=s 0 co'3 _. 0 0 � � ui �' O a E i N Ls 1 +) s[e•o9 Y p WOE yb aooa aooa aooa 8 p ewrrao aiaexH In CHHOAHnn--alaewnn dol woel M'LI m m 30 ha20,00 z�fdul s'$z 1'dN000 � � x o 2 ewvrdo aooa aooa _fi_ aooa r d01 WOad oA'4 N009 Noce Noce fdA 5z fawso NJXSz 0 ® 1 z uE u x z xQ z r w� 6 w O H lV �L$'I sJnW g w $$ v 2 F y 0 Q p ao L-i V w m m tj Um� CDo W al p Q 1 Ci O W H N J s �O e`m Op �6 jm� r Sm,� n6 o° m GE I'u m p5 s � U N Bii fiMPZi-OS'09VOZ'iiUNJaanJ- (GSOZ109WZ ld\s6uiMu0 -J\aLrsodwoJ-liedw165 Jf ll tlO6M 89cOZ�1i\sluoMdtl DnW4 ePuoe - tlUN3NtlWa9d lulu"'=�av,�.!u,:u ORRIOR CELLULAR I fZ' GLASS BITE GLAZINGTAPE F -I"THK. GLASS I /81EMPERED GLASS YZAIRSPACE 5/32ANNEALED GLASS DOW 995 0.090'PVBINTERLAYER OR (SAFLEX OR KURARAY BUrACnEj SIKA S52 # 10 x 1-1/7 PPH SMS 4 Iff ANNEALED GLASS PPHSMS 3A �,wr. mArM 9 -g GUIING DETAIL AMumInum Impact maa Be Ram L 3A ALUMINUM FRAME kUMI.Unp=�t Lfie From 20.89'D.L ' 0 MOTH * (ry4p.) Pn ALUMINUM LITIEFRAME cli4 PRIVACYINSERT I" LAMINATED INSULATED IMPACT GLASS INSERT OPTIONS 1-1 IT PPH SMS (IYP.) I FL-20468.72 .12 v 14 N INSWING THRESHOLD 32 NSH,�g Basic ComPaslle Adjustable SN7-I? ass•— y _I S3 INSWING THRESHOLD Imwng Basic Eked SIII 5.75" INSWING IHRESNOW Nswng M°tlemte Cfunote SW lam 5.75' /11NdWING THRESHOLD Intwhg Modemle Comola SO INSWING THRESHONI 36 InwAng Bask Faed 5.3 iY i 7s°� I 1 Y 37 IWIN NSGTHRESHOLD Uev4ng Bask Flxed 7-1/T'S1� T— ;; tr (11NSWING IHAESHOW Inswing Com p°sBe Atljustable Sil ^2 � INSWING THRESHOW InnNng Basic ComP.". ACusloble SO I 1 0 i. el WIWC ACCESS WAESHOW U L. I 8 SWEEP 9 SWEEP � TO SWEEP � �4.56"�I -- 2.36" T WOODJAMB T-583"� =4 /.\C WINGTHRESIIOID U Composite SN 0 4.56' �\ O'TWING THFIiSNOW CompwIte/AMO. SIII 5.75" [—,.1{II911I�-1 FLUSHBOLT U —'{1-- FLUSH BOLT," 0 RETAINER --4 �--0.126" E pym Nq 4<. K �.\OUTSWING THRESHOLD COASiALAWMINUM ASTRAGAL �d ° Compostle/Aluml—Sill 20 Qhamal Bmakl n =a wie DB 02 16 Gt � ff— Si_ o owc. er: JN S .Io 3 SIDEINESPACER SIDENLESPACER SIOEIIIE SPACER onnmw xo.: 75 IrnNtg 76 OuhwNg 77 Iruwing FL-20466.12 Moderate Climate Neshold 5 K TT11111111//// ...... .. BILL Of MATERIALS BILL OF MATERIALS CHOR ANCHOR MIN. MIN. CLEARANCE MIN CLEARANCE. i. TYPE. SIZE EMBEOMENi 'iOMASONRY TO ADJACEM = •:EDGE . ..ANCHOR._. / TAPCON ELCO 1/4' 1-1/A' T" 4" UL7RACON EVALUATION REPORT OF METAL SALES MANUFACTURING CORPORATION `26 GA. IMAGE II PAINTEL' FLORIDA BUILDING CODE 6TH EDITION (2017) FLORIDA PRODUCT APPROVAL FL 11560A-R3 ROOFING METAL ROOFING Prepared For: Metal Sales Manufacturing Corporation 545 South 3`a Street Suite 200 Louisville, KY 40202 Telephone: (502) 855-4300 Fax: (502) 855-4200 Prepared By: Bala Sockalingam, Ph.D., P.E. Florida Professional Engineer '�62240 1216 N Lansing Ave., Suite C Tulsa, OK 74106 Telephone: (918) 492-5992 FAX: (866) 366-1543 This report consists of Evaluation Report (3 Pages including cover) Installation Details (1 Page) Report No. C2181-4 Date: 9.8.2017 SCANNED BY St. Lucie County .trs;Es,aaxas�= .��GENsc .0 1. y n No 62240 n �-o •' STATE OF 7•�i t- .c:;;. 2-a l'7 FL 11560.4-R3 C2181-4 9.8.2017 Page 2 of 3 Manufacturer: Metal Sales Manufacturing Corporation Product Name: Image 11 Panel Description: Max. 16" wide coverage with I" high ribs Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or Galvalume coated steel (ASTM A792) or painted steel (ASTM A755). Deck Description: Min. 15/32" thick plywood or min.'14" thick wood plank (min SG of 0.42) for new and existing constructions. Designed and installed as per FBC 2017. Deck Attachment: 8d x 2.5" long ring shank nails or 98 x 2" long wood screws @ 6" o.c. (Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017. New Underlayment: Minimum undeda}anent as per FBC 2017 Section 1507.4.5.1. Existing Underlayment: One layer of asphalt shingles over one layer of #30 felt- For reroofing (Optional) construction only. Slope: 112:12 or greater in accordance with FBC 2017 Section 1507A.2. Requires applied lap sealant for roof slopes less than 3:12. Design Uplift Pressure: 84.25 psf @ fastener spacing of 24" o.c. (Factor of Safety = 2) Fastener Pattern: R10-12 pancake head screws along panel seam. Fastener shall be of sufficient length to penetrate through the deck a minimum of %4". Test Standards: Roof assembly tested in accordance with TAS 125.03 `Standard Requirements for Metal Roofing Systems'. Code Compliance: The product described herein has demonstrated compliance with FBC 2017 Section 1507.4_ Product Limitations: Design wind loads shall be determined for each project in accordance with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress design. The maximum fastener spacing listed herein shall not be exceeded. This evaluation report is not applicable in High Velocity Hurricane Zone_ Fire classification is not within scope of this Evaluation Report. Refer to FBC 2017 Section 1505 and current approved roofing materials directory or ASTM E108/UL790 report from an accredited laboratory for fire ratings of this product. FL 11560.4-R3 C2181-4 9.8.2017 Page 3 of 3 Supporting Documents: TAS 125 Test Reports Hurricane Test Laboratory, LLC HTL Report #: 0103-0714-09, Reporting Date 9/1/09 NEC! UNDERLAYMENT S Roof PANEL �EE DETAIL 1 —, \ 16" EXISTING UNDEflIAYMENi MINIMUM ATM: (OPTIONAL) UU x '2.5" LONGLON6 RING SHANK NAIL WOOD RAFTER/JOIST/ OR y0 x 2" LONG WOOD SCREWS MAX. 24" D.C. SPACED S" O.C. IN THE FIELD & O 4" O.C. AT PLYWOOD EDGES TYPICAL PANEL INSTALLATION X-SECTION MIN 26 CIA. PANEL NEW U14DERIAY14ENT EXISTING SHINGLES �70 PANCAKE SCREWS (OPTIONAL) \ EXISTING UNDERLAYMENT—W (OPTIONAL) PLYWOOD DETAIL 1 15/52• THICK (MIN.) O k RF A_[__` I NOTES 1, ARCHITECTURAL FLORIDA OUILDR 2. ROOF PANELS I PANEL. - IR", J. DIC ROOF PANT SPECIFIED ON 1 4. REQUIRED DESII PANEL SYSTEM ARE CRPAIER i O. ALL FASTCNCRS BUILDING CODE. REOUIREM€MS 0. IWIERS/JOIST: PANEL FASTENER SPACING PER ALLOWABLE PRESSURE TABLE. (MIN.) ALLOWABLE UPLIFT PRESSURE FASTENER PRESSURE SPACING (PSF) (IN) 24 R4.25 ✓ id BEENDESIGNED IN ACCORDANCE WITH THE MIN. 20 CA. MAX. EFFECTIVE COVERING WIDTH OF INSTALLED OVER SHEATHING & STRUCTURE AS FIF EXTERIOR RESEARCH & DESIGN, LLC. _ Certificate of Authorization #9503 - p g p 353 CHRISTIAN STREET, UNIT #13 TRUN° T ERD SCANNED OXFORD, CT 06478 BY (203) 262-9245 EVALUATION REPORT St. Lucie County TRI-BUILT Materials. Group, LLC Evaluation Report A42960.10.12-R6 PO Box 70 Rutherford, N107070 (800)516-1485 FL16048-R6 Date of issuance:10125/2012 Revision 6: 09/25/2017 SCOPE: This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen, P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The products described herein have been evaluated for compliance with the 6u' Edition (2017) Florida Building Code sections noted herein. DESCRIPTION: TRI-BUILT Roof Underlayments LABELING: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted herein. CONTINUED COMPLIANCE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product changes or the referenced Quality Assurance documentation changes. Trinity IERD requires a complete review of this Evaluation Report relative to updated Code requirements with each Code Cycle. ADVERTISEMENT: The Evaluation Report number preceded by the words "Trinity I ERD Evaluated" may be displayed in advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety. INSPECTION: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This Evaluation Report consists of pages 1 through 6 Prepared by: — .....:..r!r•.... at -� iSO.Sp.ne Robert J.M. Nieminen, P.E. Florida Registration No. 59166, Florida DCA ANE198.3 TFe fa6imda zeal a{r�eatnBbax au!Foretl np 9cFe^atleci.^.e.�, P._. acWr5r2Q3T. IDs aces no: seneazzc e'xroni_Iry zgceE cud.-et2 CERTIFICATION OF INDEPENDENCE: 1. TrinitylERD does not have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or distributing products it evaluates. 2. Trinityl ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates. 3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for which the evaluation reports are being issued. 4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product. S. This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. TRINITY ERD ROOFING COMPONENT EVALUATION: 1. SCOPE: Product Category: Roofing Sub -Category: Underlayment Compliance Statement: TRI-BUILT Roof Underlayments, as produced by TRI-BUILT Materials. Group, LLC, have demonstrated compliance with the following sections of the 6`h Edition (2017) Florida Building Code through testing in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations / Conditions of Use set forth herein. 2. STANDARDS: Section Property Standard Year 1504.3.1. Wind Resistance FM 4474 2011 1504.3.1 Wind Uplift UL 1897 2012 1504.6 Accelerated Weathering ASTM G155 2005 1507.2.4 11507.1.1, 1507.2.9.2 Physical Properties ASTM D1970 2015 1507.3.3 Physical Properties FRSA/TRI April 2012 (04-12) 2012 3. REFERENCES: Entity Examination Reference Date ERD (TST6049) Physical Properties S40540.02.13-1 02/19/2013 ERD (TST6049) Physical Properties S40540.11.13 11/19/2013 ERD (TST6049) Physical Properties S40540.03.14 03/26/2014 ERD (TSTG049) Physical Properties 544870.04.14-2 04/02/2014 ERD (TST6049) Physical Properties S44870.04.14-3 04/02/2014 ERD (TST6049) Physical Properties S44870.04.14-1 04/10/2014 ERD (TST6049) Physical Properties S44870.04.14-4 04/10/2014 ERD (TST6049) Physical Properties S43530.02.14-1-R1 05/14/2024 ERD (TST6049) Physical Properties 543530.05.14 05/28/2014 ERD (TST6049) Physical Properties S40540.10.14 10/31/2014 ERD (TST6049) Physical Properties S50645.02.15 02/13/2015 ERD (TST6049) Accelerated Weathering SC8520.04.15 05/27/2015 ERD (TST6049) Wind Resistance SC14045.05.17-R1 06/07/2017 UL, LLC. (QUA9625) Quality Control Multiple -Listing R16814 12/10/2015 UL, LLC. (QUA9625) Quality Control Service Confirmation Exp. 07/18/2020 4. PRODUCT DESCRIPTION: 4.1 Tri-Bullt Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D1970. 4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified bitumen roof underlayment; meets ASTM D1970 and FRSA/TRI April 2012. 4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS modified bitumen roof underayment; meets ASTM D1970. S. LIMITATIONS: 5.1 This is a building code evaluation. Neither TrinityJERD nor Robert Nieminen, P.E. are, in any way, the Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained specifically for that purpose. 5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions. 5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials Directory for fire ratings of this product. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6 certificate of Authorization#9503 6r"EDITION (2017)FBC NON-HVHZ EVALUATION PL16048-116 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017 Page 2 of 6 TRINITY ERD 5.4 TRI-BUILT Roof Undedayments may be used with any prepared roof cover where the product is specifically referenced within FBC approval documents. If not listed, a request may be made to the Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the prepared roof covering. 5.5 Allowable Roof Covers: TABLE 1: ROOF COVER OPTIONS Underlayment Asphalt Shingles Nail -On Tile Foam -On Tile Metal Wood Shakes Slate & Shingles ' Tri-Built Sand-R SA Shingle Underlayment Yes No No No Yes Yes Tri-Built S/A HT TU yes Underlayment Yes j Yes See 5.5.1 Yes Yes Yes j Tri-Built Smooth HT S/A Underlayment Yes No No Yes Yes Yes 5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations. TABLE IA: ALLOWABLE TILE ADHESIVE / UNDERLAYMENT COMBINATIONS1 Adhesive Florida Product Approval I Underlayments ICP Adhesives Polysete AH-160 FL6332 Tri-Built S/A HT TU Underlayment Dow TileBondT" FL22525 Tri-Built S/A HT TU Underlayment 5.6 Allowable Substrates: 5.6.1 Direct -Bond to Deck: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41 primed Southern Yellow Pine; ASTM D41 primed structural concrete. While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note: TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or OSB prior to installation of the self -adhering underlayment. - 5.6.2 Bond -to -Insulation: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board. For installation under mechanically attached prepared roof coverings, insulation shall be attached per minimum requirements of the prepared roof covering manufacturer's Product Approval. For installations under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be designed by a qualified design professional and installed based on testing of the insulationfunderlayment system in accordance with FM 4474, Appendix D orTAS 114, AppendixJ. ' Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida Product Approval for Overturning Moment Resistance Performance. Exterior Research and Design, LLC Evaluation Report A42960.10.12-R6 CertiTicote ofAuthorizotion N9503 6' EDITION (2017) FB`c NON-HVHZ EVALUATION FL 16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017 Page 3 of 6 TRINITY ERD 5.6.3 Bond to Mechanically Attached Base Laver: Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A Underlayment applied to: ASTM D226, Type I or 11 felt. For installations under mechanically attached prepared roof coverings, base layer shall be attached per - - minimum codified requirements. For installations under foam -on tile systems (Tri-Bulk S/A HT TU Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04- 12). 5.6.4 Wind Resistance for Underlayment Systems in Foam -On rile Applications: FRSA/TRI April 2012 (04-12) does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on tile applications. Maximum Design Pressure is the result of testing for wind load resistance based on allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 3A or FBC 1609 for determination of design wind pressures. #1 Maximum Design Pressure =-45.0 psf: Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered. #2 Maximum Design Pressure =-67.5 psf: Deck: Structural concrete to meet project requirements to satisfaction of Authority Having Jurisdiction. Primer: Soprema Elastocol 600c Underlayment: Tri-Built 5/A HTTU Underlayment, self -adhered. #3 Maximum Design Pressure=-150.0 osf Deck: Min. 15/32-inch APA-rated BCX plywood (may be installed C-side up) to meet project requirements to satisfaction of Authority Having Jurisdiction. Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp splinters and wood projections shall be removed/sanded. Primer: (Optional) RESISTO EXTERIOR PRIMER Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand roller and/or weighted roller to ensure there are no voids, and ensure there are no voids/bridging at side and end -laps. #4 Maximum Design Pressure =-60.0 psf: Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority HavingJurisdiction- BaseSheet: Underlayment: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1) and tin caps (FBC 1517.5.2) spaced 64nch o.c. at the 4-inch laps and 6-inch o.c. in three, equally spaced rows in the center of the sheet. Tri-Built S/A HT TU Underlayment, self -adhered. Exterior Research and Design, I.I.C. Evaluation Report A42960.10.12-R6 Cerffflcote afAuthorkotion s9503 6'EDITION (20171 FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6:09/25/2017 Page 4 of 6 TPJNITY ERD 5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A. Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1 design pressure determined in accordance with FBC 1609. In this case, Zones 2 and 3 shall employ an attachment density designed by a qualified design professional to resist the elevated pressure criteria. Commonly used methods are ANSI/SPRI WDS, FM Loss Prevention Data Sheet 1-29 and Roofing Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements. 5.7 Exposure Limitations: Tri-Built Sand-R SA Shingle Underlayment or TA -Built Smooth HT 5/A Underlayment shall not be left exposed for longer than 30-days after installation Tri-Built S/A HT TU Underlayment shall not be left exposed for longer than 180-days after installation. 5.8 Tile Slippage Limitations (TAS 103 per FRSA/TRI April 2012 (04-12))- When loading roof tiles on the underlayment in direct -deck tile assemblies, the maximum roof slope shall be as follows. These slope limitations can only be exceeded by using battens during loading of the roof tiles. TABLE 2: TILE SLIPPAGE LIMITATIONS FOR DIRECT DECK TILE INSTALLATIONS Underlayment Tile Profile Staging Method Maximum Slope Flat Max. 10-tile stack 6:12 Lugged Max. 10-tile stack 5:12 Max. 10-tile stack (bottom 2-tile stack shall be inverted, followed by 8 tiles high 6:12 on slope, as shown below) tlt Tri-Built S/A HT TU- Underlayment Lugged Exterior Research and Design, LLC Evaluation Report A42960.10.12-R6 Certificate of Authorization A9503 6" EDITION (20171 FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; [Soo) 516-1485 Revision 6:09/25/2017 Page 5 of 6 R1NJ_ Y ERD S. INSTALLATION: 6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC published installation requirements subject to the Limitations set forth in section 5 herein and the specifics noted below. 6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly to remove any dust and debris priorto application, andprimethe substrate (if applicable). 6.3 Tri-Built Sand-R SA Shingle Underlavment Tri-Built S/A HT TU Underlavment or Tri Built Smooth HT S/A Underlavment 63.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table 1507.1.1 for the type of prepared roof covering to be installed. 6.3.2 Non -Tile applications: While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Apply sheet parallel to the roof edge. Roll out approximately 10 ft of membrane and peel back the first 3 ft of release film. Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible. Once the entire length of membrane is in place, peel -off the release film diagonally while holding the membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond. Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6- inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with TRI-BUILT Materials Group, LLC requirements. When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the overlap area at the top of the sheet at 12-inch o.c. For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in each direction. For valleys, apply the sheet starting at the lowest point and work upward. 6.3.3 Tile Applications (Tri-Built S/A HT TU Underlavment only): Reference is made to FRSA/TRI April 2012 (04-12) Installation Manual and Table 1 herein, using the instructions noted above as a guideline. For foam -on tile applications, reference is made to Section 5.6.4 herein for wind resistance limitations that fall outside the scope of FRSA/TRI April 2012 (04-12). Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile staging. 7. BUILDING PERMIT REQUIREMENTS: As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of this product. B. MANUFACTURING PLANTS: Gulfport, MS 9. QUALITY ASSURANCE ENTITY: UL, LLC —QUA9625; (314) 578-3406; k.chancellor@us.ul.com - END OF EVALUATION REPORT - Exterior Research and Design, LLC. Evaluation Report A42960.10.12-116 Certificate of Authorization#9503 6r"EDITION (2017)FBC NON-HVHZ EVALUATION FL16048-R6 TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2D17 Page 6 of 6