HomeMy WebLinkAboutEVALUATION REPORTM,
�a-V��
EVALUATION REPORT OF - REVIEWED FOR
METAL SALES MANUFACTURING CORPORAtME COMPLIANCE
°26 GA. 5V-CRIMP PANEL'
l�OCC
sc�rLFo ST= LaJCEE COUNTYa
9
s�APy
'�`%n9 1119
�4ci spa FLORIDA BUILDING -CODE 6TH EDITION (2017)
°linty eat FLORIDA PRODUCT APPROVAL
FL 14645.3-R3
ROOFING
METAL ROOFING FILE C®
SCANNED
BY
Prepared For: ;1 Lucie County
Metal Sales Manufacturing Corporation
545 South 3rd Street, Suite 200
Louisville, KY 40202
Telephone: (502) 855-4300
Fax: (502) 855-4200
Prepared By:
Bala Sockalingam, Ph.D., P.E.
Florida Professional Engineer #62240
1216 N Lansing Ave., Suite C
Tulsa, OK 74106
Telephone: (918) 492-5992
FAX: (866) 366-1543
This report consists of
EvaluationInstallation Details (1 Page) eport (3 Pages g cover) ``,`��SOCKAQ 4,�e
Report No. C2182-3
Date: 9.9.17
`��yP.•0ENS G9'.o
o`�P�•No 622407.
.
-53 STATE OF :4�.
O'•
..c� ORX
�4i S`4 O N AW�1`
q,g.
,J�
FL 14645.3-R3
C2182-3
9.9.17
Page 2 of 3
Manufacturer: Metal Sales Manufacturing Corporation
Product Name: 5V-Crimp
Panel Description: 24" wide coverage with (5) 1/2" high ribs
Materials: Min. 26 ga., 50 ksi steel. Galvanized coated steel (ASTM A653) or
Galvalume coated steel (ASTM A792) or painted steel (ASTM A755).
Deck Description: Min. 19/32" plywood or min. 3/4" thick wood plank (min SG of 0.42)
for new and existing constructions. Designed by others and installed
as per FBC 2017.
Deck Attachment: 8d x 2.5" long ring shank nails or #8 x 2" long wood screws @ 6" o.c.
(Minimum) in the field and @ 4" o.c. at edges. Designed as per FBC 2017.
New Underlayment: Minimum underlayment as per FBC 2017 Section 1507.4.5.1.
Required for new construction and optional for reroofing construction.
Existing Underlayment: One layer of asphalt shingles over one layer of ifN felt. For reroofing
(Optional) construction only.
Slope: 1/2:12 or greater in accordance with FBC 2017 Section 1507.4.2.
Requires applied lap sealant for roof slopes less than 3:12.
Design Uplift Pressure: 41.6 psf @ fastener spacing of 36" o.c.
(Factor of Safety = 2) 74.8 psf @ fastener spacing of 16" o.c.
196.75 psf @ fastener spacing of 8" o.c.
Fastener Pattern:
Type: #9-16 or #10-14 hex head wood screws with sealed washer. Fastener
'shall be of sufficient length to penetrate through the deck a minimum
of 3/8".
At panel ends @ 6" o.c. across panel width
At intermediate @ 12" o.c. across panel width
Test Standards: Roof assembly tested in accordance with TAS 125-03 `Standard
Requirements for Metal Roofing Systems'.
Code Compliance: The product described herein has demonstrated compliance with FBC
2017 Section 1507.4.
Product Limitations: Design wind loads shall be determined for each project in accordance
with FBC 2017 Section 1609 or ASCE 7-10 using allowable stress
design. The maximum support spacing listed herein shall not be
exceeded. This evaluation report is not applicable in High Velocity
FL 14645.3-R3
C2182-3
9.9.17
Page 3 of 3
Hurricane Zone. Fire classification is not within scope of this
Evaluation Report. Refer to FBC 2017 Section 1505 and current
approved roofing materials directory or ASTM E108/UL790 report
from an accredited laboratory for fire ratings of this product.
Supporting Documents: TAS 125 Test Reports
Farabaugh Engineering and Testing Inc
Project No. T181-05, Reporting Date 7/21/05 (Tests #1 & 2)
Project No. T240-09, Reporting Date 9/22/09
Architectural Testing, Inc. — West Palm Beach, FL
(Formerly Hurricane Test Laboratory, LLC)
Project No. 0103-0712-09, Reporting Date 9/1/09
NEW UNDERLAYMENT -
(REQUIRED ONLY FOR
NEW CONSTRUCTION)
EXISTING UNDERLAYMENT
(OPTIONAL)
NEW UNDERLAYMENT-
(REQUIRED ONLY FOR
NEW CONSTRUCTION)
EXISTING SHINGLES
(OPTIONAL)
EXISTING UNDERLAYMENT
(OPTIONAL)
SEE DETAIL 2 / — PAETAIL NEL OVERLAP)'
FASTENER AT PANEL FLAT
REQUIRED FOR PANEL
ENDS ONLY.
EXISTING UNDERLAYMENT /
(OPTIONAL) MINIMUM " LONGMRIN
Bd z 7.5° LONG RING SHANK NAIL
OR Q8 z 2" LONG WOOD SCREWS
SPACED ® 6" O.C. IN THE FIELD &
MIN. 2X— WOOD RAFTER/JOIST/ 4" O.C. AT PLYWOOD EDGES
TRUSS AT MAX. 24" O.C.
TYPICAL PANEL INSTALLATION X-SECTION
N9-16 OR A10-14 WOODECREWS
WITH SELF EALING WASHER AT
MAXIMUM SPACING OF 36' O.C.
5V—CRIMP
MIN 26 GA.
�— PLYWOOD
DETAIL 1 18/32- THICK (MIN.)
N9-16 OR ,10-14 WOODSCREWS
WITH SELF SEALING WASHER AT
MAXIMUM SPACING OF 36" O.C.
DETAIL 2
SV-CRIMP
MIN 26 GA.
(MIN.)
PANEL FASTENER PER
PRESSURE TABLE ON
5V—CRIMP
ALLOWABLE UPLIFT PRESSURE
FASTENER
SPACING
(IN)
PRESSURE
(PSF)
36
41.6
16
74.8
8
196.75
GENERAL NOTES:
1. ARCHITECTURAL ROOF PANEL HAS BEEN DESIGNED IN ACCORDANCE WITH THE
FLORIDA BUILDING CODE (FBC).
2. ROOF PANELS SHALL BE MIN. 26 GA. (t = 0.0169'). EFFECTIVE COVERING
WIDTH OF PANEL - 24".
3. THE ROOF PANELS SHALL BE INSTALLED OVER SHEATHING & STRUCTURE AS
SPECIFIED ON THIS DRAWING.
4. REQUIRED DESIGN WIND LOADS SHALL BE DETERMINED FOR EACH PROJECT. THIS
PANEL SYSTEM MAY NOT BE INSTALLED WHEN THE REQUIRED DESIGN WIND LOADS
ARE GREATER THAN THE ALLOWABLE WIND LOADS SPECIFIED ON THIS DRAWING,
S. ALL FASTENERS MUST BE IN ACCORDANCE WITH THIS DRAWING & THE FLORIDA
BUILDING CODE, IF A DIFFERENCE OCCURS BETWEEN THE MINIMUM
REQUIREMENTS OF THIS DRAWING & THE CODE, THE CODE SHALL CONTROL.
6. RAFTERS/JOISTS/TRUSSES MUST BE DESIGNED TO WITHSTAND WIND LOADS AS
REQUIRED FOR EACH APPLICATION AND ARE THE RESPONSIBILITY OF OTHERS,
m
� 9'O9 �CFfa
EXTERIOR RESEARCH & DESIGN, U.C.
�0 Certificate of Authorization N9503
TRINITY I ERD , 0 353 CHRISTIAN STREET, UNIT #13
Gar �P-r OXFORD, CT 06478
(203)262-9245
EVALUATION REPORT
TRI-BUILT Materials Group, LLC Evaluation Report A42960.10.12-R6
PO Box 70 SCANNED
Rutherford, 07070 BY Date of Issuance:10/25/2012
(800) 516-1485 St. Lucie County Revision 6: 09/25/2017
SCOPE:
This Evaluation Report is issued under Rule 61G20-3 and the applicable rules and regulations governing the use of
construction materials in the State of Florida. The documentation submitted has been reviewed by Robert Nieminen,
P.E. for use of the product under the Florida Building Code and Florida Building Code, Residential Volume. The
products described herein have been evaluated for compliance with the a Edition (2017) Florida Building Code
sections noted herein.
DESCRIPTION: TRI-BUILT Roof Underlayments
LABEUNG: Labeling shall be in accordance with the requirements the Accredited Quality Assurance Agency noted
herein.
CONTINUED ComPuANcE: This Evaluation Report is valid until such time as the named product(s) changes, the referenced
Quality Assurance documentation changes, or provisions of the Code that relate to the product change. Acceptance of
this Evaluation Report by the named client constitutes agreement to notify Robert Nieminen, P.E. if the product
changes or the referenced Quality Assurance documentation changes. Trinityi ERD requires a complete review of this
Evaluation Report relative to updated Code requirements with each Code Cycle.
ADVERTISEMENT: The Evaluation Report number preceded by the words "TrinityiERD Evaluated" may be displayed in
advertising literature. If any portion of the Evaluation Report is displayed, then it shall be done in its entirety.
INsPEmoN: Upon request, a copy of this entire Evaluation Report shall be provided to the user by the manufacturer or
its distributors and shall be available for inspection at the job site at the request of the Building Official.
This Evaluation Report consists of pages 1 through 6.
Prepared by:
Robert J.M. Nieminen, P.E.
Florida Registration No. 59166, Florida DCA ANE3983
Theft M.aea1 Pp .angoras aUflo ea by Robe"NieM.n,
rEoa oelss/mv. m�aee: �,m:arve a, an e�ee,omaoyasaea
aaamenc
CEIMEMAiION OF INDEPENDENCE:
1. TrinitylERD does hot have, nor does it intend to acquire or will it acquire, a financial interest in any company manufacturing or
distributing products it evaluates.
2. Trinity I ERD is not owned, operated or controlled by any company manufacturing or distributing products it evaluates.
3. Robert Nieminen, P.E. does not have nor will acquire, a financial interest in any company manufacturing or distributing products for
which the evaluation reports are being issued.
4. Robert Nieminen, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the
product.
S. This is a building code evaluation. Neither Trinity[ ERD not Robert Nieminen, P.E. are, in any way, the Designer of Record for any
project on which this Evaluation Report, or previous versions thereof, is/was used for permitting or design guidance unless retained
specifically for that purpose.
�f I KINITY J ERD
ROOFING COMPONENT EVALUATION:
1. SCOPE:
Product Category Roofing
Sub -Category: Underlayment
Compliance Statement: TBI-BUILT Roof Underlayments, as produced by-TRF-BUILT Materials Group, LLC, have
demonstrated compliance with the following sections of the 6'I' Edition (2017) Florida Building Code through testing
in accordance with the following Standards. Compliance is subject to the Installation Requirements and Limitations /
Conditions of Use set forth herein.
2. STANDARDS:
Section
Property
Standard
Year
1504.3.1
Wind Resistance
FM 4474
2012
1504.3.1
Wind Uplift
UL 1897
2012
1504.6
Accelerated Weathering
ASTM G355
2005
1507.2.4 / 1507.1.1,1507.29.2
Physical Properties
ASTM D1970
2015
1507.3.3
Physical Properties
FRSA/TRI April 2012 (04-12)
2012
3. REFERENCES:
Entitv
Examination
Reference
Date
ERD (TST6049)
Physical Properties
S40540.02.13-1
02/19/2013
ERD (TST6049)
Physical Properties
S40540.11.13
11/19/2013
ERD (TST6049)
Physical Properties
S40540.03.14
03/26/2014
ERD (TST6049)
Physical Properties
S44870.04.14-2
04/02/2014
ERD (TST6049)
Physical Properties
S44870.04.14-3
04/02/2014
ERD W6049)
Physical Properties
544870.04.14-1
04/10/2014
ERD W6049)
Physical Properties
S44870.04.14-4
04/10/2014
ERD (TST6049)
Physical Properties
S43530.02.14-1-R1
05/14/2014
ERD (TST6049)
Physical Properties
S43530.05.14
05/28/2014
ERD W6049)
Physical Properties
S40540.10.14
10/31/2014
ERD (TST6049)
Physical Properties
SC7645.02.15
02/13/2015
ERD(TST6049)
Accelerated Weathering
SC8520.04.15
D5/27/2015
ERD (TST6049)
Wind Resistance
SC14045.05.17-R1
06/07/2017
UL, LLC. (QUA9625)
Quality Control
Multiple -Listing R16814
12/10/2015
UL, LLC.(QUA9625)
Quality Control
Service Confirmation
Exp.07/18/2020
4. PRODUCT DESCRIPTION:
4.1 Tri-Built Sand-R SA Shingle Underlayment is a self -adhering, glass -mat reinforced, sand -surfaced, SBS
modified bitumen roof underlayment, with a 36-inch sheet width; meets ASTM D3970.
4.2 Tri-Built S/A HT TU Underlayment is a self -adhering, non -woven polyester fabric surfaced, SBS modified
bitumen roof Underlayment; meets ASTM D1970 and FRSA/TRI April 2012.
4.3 Tri-Built Smooth HT S/A Underlayment is a self -adhering, glass -mat reinforced, film -surfaced, SBS
modified bitumen roof underlayment; meets ASTM D1970.
S. LIMITATIONS:
5.1 This is a building code evaluation. Neither Trinityl ERD nor Robert Nieminen, P.E. are, in any way, the
Designer of Record for any project on which this Evaluation Report, or previous versions thereof, is/was
used for permitting or design guidance unless retained specifically for that purpose.
5.2 This Evaluation Report is not for use in FBC HVHZ jurisdictions.
5.3 Fire Classification is not part of this Evaluation Report; refer to current Approved Roofing Materials
Directory for fire ratings of this product.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6
Cerd lmM ofAudiodratlan 900 6' EDITION (2017) FBC NON-HVHZ EVALUATION FL16048-RG
TRI-BUILT Roof Undedayments; (800) 516-1485 Revision 6: 09/ZS/2017
Page 2 of 6
i-\
�1 TRINITY J ERD
5.4 TRI-BUILT Roof Underlayments may be used with any prepared roof cover where the product is
specifically referenced within FBC approval documents. If not listed, a request may be made to the
Authority Having Jurisdiction for approval based on this evaluation combined with supporting data for the
prepared roof covering.
5.5 Allowable Roof Covers:
- -- , yTABLE 1: ROOF Ciil"OFr1oNs . •. ... . . .
Underlayment
Asphalt
Nall-OnTile
Foam -On Tile
Metal
Wood Shakes
Slate
Shingles
& Shingles
Tri-Built Sand-R SA Shingle
Underlayment
Yes
No
No
No
Yes
Yes
Tri-Built S/A HT TU
Yes
Underlayment
Yes
Yes
See 5.5.1
Yes
Yes
^
Yes
'Tr1`BmIt Smooth HTSHTS/A
----
ti -
„_,.
Underlayment-" .-N..�.,n_;1rh-r.'i,—
•Y
.,
, ,�
Yes
Yes
Yes
-
5.5.1 "Foam -On Tile" is limited to use of the following Approved tile adhesives / underlayment combinations.
,.. ..� _. .. _ _... .. _ , . 1 . .,
:TABLE 1/t:,ALIOWABLETILE AD HESIVE/UNDERIAYMENT COMBINATIOM1LS.- .,,. .. ..
Adhesive
Florida Product Approval
Underlayments
ICP Adhesives Polyset° AH-160
FL6332
Tri-Built S/A HT TU Underlayment
Dow TileBond^'
FL22525
Tri-Built S/AHTTUUnderlayment
5.6 Allowable Substrates:
5.6.1 Direct -Bond to Deck:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Plywood; ASTM D41 primed plywood; OSB; ASTM D41 primed OSB; Southern Yellow Pine; ASTM D41
primed Southern Yellow Pine; ASTM D41 primed structural concrete.
While not required over plywood, OSB or Southern Yellow Pine substrates, TRI-BUILT Materials Group, LLC
recommends priming the deck if the final roof cover is not slated for installation within 24 hours. Note:
TRI-BUILT Materials Group, LLC requires tongue -and -groove board decking be covered with plywood or
OSB prior to installation of the self -adhering underlayment.
5.6.2 Bond -to -insulation:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ Dens Deck Prime; SECUROCK Gypsum -Fiber Roof Board.
For installation under mechanically attached prepared roof coverings, insulation shall be attached per
minimum requirements of the prepared roof covering manufacturers Product Approval. For installations
under foam -on tile systems (Tri-Built S/A HT TU Underlayment only), insulation attachment shall be
designed by a qualified design professional and installed based on testing of the insulation/underlayment
system in accordance with FM 4474, Appendix D. or TAS 114, Appendix J.
1 Refer to Tile Manufacturer's or Adhesive Manufacturer's Florida ProductApproval for Overturning Moment Resistance Performance.
Exterior Research and Design, U.C. Evaluation Report A42960.10.12-R6
Certificate of Authorization tl9503 6'"EDITION (2017)FBC NON-HVH2 EVALUATION FL16048-R6
TRI-BUILT Roof Underlayments; (800) 516-1485 Revision 6: 09/25/2017
Page 3 of 6
TRINITY 1 ERD
5.6.3 Bond to Mechanically Attached Base Laver:
Tri-Built Sand-R SA Shingle Underlayment, Tri-Built S/A HT TU Underlayment or Tri-Built Smooth HT S/A
Underlayment applied to:
➢ ASTM D226, Type I or II felt.
For installations under mechanically attached prepared roof coverings, base layer shall be attached per
minimum codified requirements. For installations under foam -on the systems (Tri-Built S/A HT TU
Underlayment only), base layer shall be attached per minimum requirements of FRSA/TRI April 2012 (04-
12).
5.6.4 Wind Resistance for Underlayment Systems in Foam -On Tile Applications: FRSA/TRI April 2012 (04-12)
does not address wind uplift resistance of all underlayment systems beneath foam -on tile systems, where
the underlayment forms part of the load -path. The following wind uplift limitations apply to direct -deck
underlayment systems that are not addressed in FRSA/TRI April 2012 (04-12) and are used in foam -on the
applications. Maximum Design Pressure is the result of testing for wind load resistance based on
allowable wind loads, and reflects the ultimate passing pressure divided by 2 (the 2 to 1 margin of safety
per FBC 1504.9 has already been applied). Refer to FRSA/TRI April 2012 (04-12), Appendix A, Table 1A or
FBC 2609 for determination of design wind pressures.
#1 Maximum Design Pressure =-45.0 osf:
Deck: Min. 15/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Primer: (Optional) ASTM D41 or RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered.
#2 Maximum Design Pressure =-67.5 psf:
Deck: Structural concrete to meet project requirements to satisfaction of Authority Having
Jurisdiction.
Primer: Soprema Elastocol 600c
Underlayment: Tri-Built S/A HTTU Underlayment, self -adhered.
#3 Maximum Design Pressure = -150.0 osf-
Deck: Min. 15/32-inch APA-rated BOX plywood (may be installed C-side up) to meet project
requirements to satisfaction of Authority Having Jurisdiction.
Deck Preparation: Plywood shall be thoroughly cleaned to remove dust and debris that may inhibit
adhesion. All sheathing fasteners shall be driven flush with the surface. All sharp
splinters and wood projections shall be removed/sanded.
Primer: (Optional) RESISTO EXTERIOR PRIMER
Underlayment: Tri-Built S/A HT TU Underlayment, self -adhered, shall be thoroughly roll using hand
roller and/or weighted roller to ensure there are no voids, and ensure there are no
voids/bridging at side and end -laps.
#4 Maximum Design Pressure=-60.0 Dsf,
Deck: Min. 19/32-inch plywood to meet project requirements to satisfaction of Authority
Having Jurisdiction.
Base Sheet: Soprema Sopra-G or Modified Sopra-G mechanically attached with nails (FBC 1517.5.1)
and tin caps (FBC 1517.5.2) spaced 6-inch o.c. at the 4-inch laps and 6-inch o.c, in three,
equally spaced rows in the center of the sheet.
Underlayment: Tri-BuiltS/A HT TU Underlayment, self -adhered.
Exterior Research and Design, U.C. Evaluation ReportA42960.10.12-R6
Certff¢ote ofAudrorkirtioo 99503 6'"EDmON(2017)FBC NON-HVH2 EVALUATION FL16048-R6
TRFBUILT Roof Underlaymesns, (800) 516-1485 Revision 6: 09/25/2017
Page 4 of 6
\,�TWNITY I ERD
5.6.4.1 For mechanically attached Base Sheet, the maximum design pressure for the selected assembly shall meet
or exceed that required under FRSA/TRI April 2012 (04-12), Appendix A, Table 1A.
Alternatively, the maximum design pressure for the selected assembly shall meet or exceed the Zone 1
design pressure determined in accordance with FK 1609. In this case, Zones 2 and 3 shall employ an
attachment density designed by a qualified design professional to resist the elevated pressure criteria.
- Commonly used methods are ANSI/SPRI WD3, FM -Loss Prevention DataSheet1-29 and Roofing
Application Standard RAS 117. Assemblies marked with an asterisk* carry the limitations set forth in
Section 2.2.10.1 of FM Loss Prevention Data Sheet 1-29 (January 2016) for Zone 2/3 enhancements.
5.7 Exposure Limitations:
Tri-Built Sand-R SA Shingle Underlayment or Tri-Built Smooth HT S/A Underlayment shall not be left
exposed for longer than 30-days after installation
Tri-Built S/A HTTU Underlayment shall not be left exposed for longer than 180-days after installation.
5.8 Tile Slippage Umitations (TAS 103 per FRSA/!RI April 2012 (04-121):
When loading roof tiles on the underlayment in direct -deck file assemblies, the maximum roof slope shall
be as follows. These slope limitations can only be exceeded by using battens during loading of the roof
tiles.
:1 •, ySLIPPAGE LIMRA710NS FOR DIRri7-DEOC,TnEINSFArlAT10Ns..
.
-`.`.,,TABIE2:TIIE
Underlayment
Tile Profile
Staging Method
Maximum
Slope
Flat
Max:10-tile stack
6:12
Lugged
Max. 10-tile stack
5:12
Max.10-tile stack (bottom 2-tile stack
shall be inverted, followed by B tiles high 6:12
on slope, as shown below)
Tri-Built S/AHTTU
i'
Underlayment.:�.,,
Lugged
Exterior Research and Design, U.C. Evaluation ReportA42960.10.12-R6
CerttflaateofAuthorhadon99903 6�"EDITION (2017)FBC NON-HVHZ EVALUATION FL26048-RG
TRI-BUILT Roof Underlaymemr (800) 516.148S Revision 6: 09/25/2017
Page 9 of 6
`J 1 RINIZY j ERD
6. INSTALLATION:
6.1 TRI-BUILT Roof Underlayments shall be installed in accordance with TRI-BUILT Materials Group, LLC
published installation requirements subject to the Limitations set forth in Section 5 herein and the
specifics noted below.
6.2 Re -fasten any loose decking panels, and check for protruding nail heads. Sweep the substrate thoroughly
to remove any dust -and debris prior to application, and prime the substrate (if applicable).
6.3 Tri-Built Sand-R SA Shingle Underlavment Tri-Built S/A HT TU Underlavment or Tri-Built Smooth HT S/A
Underlavment:
6.3.1 Shall be installed in compliance with the requirements for ASTM D1970 underlayment in FBC Table
1507.1.1 for the type of prepared roof covering to be installed.
6.3.2 Non -Tile applications:
While priming is optional, TRI-BUILT Materials Group, LLC recommends priming the deck if the final roof
cover is not slated for installation within 24 hours.
Apply sheet parallel to the roof edge. Roll out approximately 10 fit of membrane and peel back the first 3
ft of release film.
Adhere the exposed part to the substrate and unroll the remaining membrane as far as possible.
Once the entire length of membrane is in place, peel -off the release film diagonally while holding the
membrane tight. Firmly roll, broom or hand -press the membrane into place to achieve a bond.
Horizontal seams should be minimum 3-inches, configured to shed water. Vertical seams should be 6-
inches and staggered not less than 2-ft from vertical seams in the course below, sealed in accordance with
TRI-BUILT Materials Group, LLC requirements.
When installing at slopes above 8:12, TRI-BUILT Materials Group, LLC recommends back -nailing in the
overlap area at the top of the sheet at 12-inch o.c
For Valleys and Ridges: Cut underlayment into 4 to 6 foot lengths. Peel the release paper and center sheet
over valley or ridge. Drape and press sheet into place, working from the center of the valley or ridge in
each direction. For valleys, apply the sheet starting at the lowest point and work upward. .
6.3.3 Tile Applications (Tri-Built S/A HT TU Underlavment only):
Reference is made to FRSA/TRI April 2012 (04-22) Installation Manual and Table 1 herein, using the
instructions noted above as a guideline.
For toam-on tile applications, reference is made to Section S.6.4 herein for wind resistance limitations that
fall outside the scope of FRSA/TRI April 2012 (04-12).
Tile shall be loaded and staged in a manner that prevents tile slippage and/or damage to the
underlayment. See Table 2 herein, and TRI-BUILT Materials Group, LLC published requirements for tile
staging.
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or Authority Having Jurisdiction in order to properly evaluate the installation of
this product.
8. MANUFACTURING PLANTS:
Gulfport, MS
9. QUALITY ASSURANCE ENTITY:
UL, LLC—QUA9625; (314) 578-3406; k.chancellor@us.ul.com
Exterior Research and Design, I.I.C.
Certificate ofAuthonratfon 09503
- END OF EVALUATION REPORT -
6ry EDITION (2017) FBC NON-HVHZ EVALUATION
TRFBUILT Roof Underlayments; (WO) 516-1485
Evaluation Report A42960.10.12-116
FL16048-R6
Revision 6: 09/25/2017
Page 6 of 6