Loading...
HomeMy WebLinkAboutNOAMIMI M DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BOARD AND CODE ADMINISTRATION DIVISION NOTICE OF ACCEPTANCE (VOA) Entegra Roof Tile, LLC 1289 NE 9"' Ave Okeechobee, FL. 34972 MIAMI-DADE COUNTY SCANNEI RODUCT CONTROL SECTION 11805 SW 26 Street, Room 208 By Miami, Florida 33175-2474 St. Lucie Couf4t�786)315-2s90 F (786) 315-2599 www.miamidade.eov/economy SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Galena Spanish "S" Concrete Roof Tile LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This renews and revises NOA 10-0518.04 and consists of pages 1 through 6. The submitted documentation was reviewed by Juan E. Collao, R.A. NOA No.: 14-0416.12 Expiration Date: 11/18/19 Approval Date: 11/27/14 Page 1 of 6 ROOFING ASSEMBLY APPROVAL Category: Roofing Sub -Category: Roofing Tiles Material: Concrete 1. SCOPE This approves a roofing system using Galena Spanish "S" Concrete Roof Tile, as manufactured by Entegra Roof Tile, LLC as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using the values listed in section 4 herein. The attachment calculations shall be done as a moment based system. 2. PRODUCT DESCRIPTION Manufactured by Test Product Applicant Dimensions Specifications Description Oalena Spanish `S' Roof L = 17" TAS 112 High profile, interlocking, one-piece, "S" Tile W = 10" shaped, concrete roof tile equipped with H = 2.7" two nail holes. For direct deck or Thickness: %" battened nail -on, mortar or adhesive set applications. Trim Pieces L = varies TAS 112 Accessory trim, concrete roof pieces for W = varies use at hips, rakes, ridges and valley Varying thickness terminations. Manufactured for each tile profile. 2.1. MANUFACTURING LOCATION 1. Okeechobee, FL 2.2. EVIDENCE SUBMITTED Test Agency Test Identifier Test Name/Reyort Date Redland Technologies 7161-03 Static Uplift Testing Dec. 1991 Appendix III PA 102 & PA 102(A) Redland Technologies 7161-03 Wind Tunnel Testing Dec. 1991 Appendix II PA 108 (Nail -On) Redland Technologies P0647-01 Wind Tunnel Testing Aug. 1994 PA 108 (Mortar Set) Redland Technologies P0402 Withdrawal Resistance Testing of Sept. 1993 screw vs. smooth shank nails The Center for Applied 94-084 Static Uplift Testing May 1994 Engineering, Inc. PA 101 (Mortar Set) The Center for Applied 94-083 Static Uplift Testing April 1994 Engineering, Inc. PA 161 (Adhesive Set) NOA No.: 14-0416.12 MAMI•DADE COUNTY Expiration Date: 11/18/19 Approval Date: 11/27/14 Page 2 of 6 Test Agency The Center for Applied Engineering, Inc. The Center for Applied Engineering, Inc. Redland Technologies The Center for Applied Engineering, Inc. Nutting Engineering Celotex Corporation Testing Service Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Walker Engineering, Inc. Test Identifier 25-7183-4 25-7214-3 Letter Dated Aug. 1, 1994 Project No. 307025 Test #MDC-78 13343.1 520111-3 520191-2-1 Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Evaluation Calculations Calculations American Test Lab of South RT0624.04-14 Florida I LIMITATIONS 3.1 Fire classification is not part of this acceptance. Test Name/Report Static Uplift Testing PA 102 (2 Quik-Drive Screws, Direct Deck) Static Uplift Testing PA 102 (1 Quik-Drive Screw, Direct Deck) Wind Tunnel Testing PA 108 (Nail -On) Wind Driven Rain PA 100 Physical Properties TAS 112 Static Uplift Testing PA 101 Two Patty Adhesive Set System 25-7094 25-7496 25-7584 25-7804b-8 25-7804-4 & 5 25-7848-6 25-7183 Restoring Moment Due to Gravity Aerodynamic Multiplier TAS 112 Date Feb. 1995 March, 1995 Aug. 1994 Oct. 1994 June 2007 Dec. 1998 March 1999 April 1999 February 1996 April 1996 December 1996 March 1995 09/14/09 09/14/09 07/07/14 3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with TAS 106. 3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product Control office for review. 3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed section 4.1 herein. 3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated otherwise by the underlayment material manufacturers published literature. 3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with applicable building code. 3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61G20-3 of the Florida Administrative Code. MAHMADE COUNTY NOA No.: 14-0416.12 [TIT. Imp Expiration Date: 11/18/19 Approval Date: 11/27/14 Page 3 of 6 4. INSTALLATION 4.1 Galena Spanish "S" Concrete Roof Tile and its components shall be installed in strict compliance with Roofing Application Standard RAS 118, RAS 119 and RAS 120. 4.2 Data For Attachment Calculations Table 1: Average Weight (W) and Dimensions (I x w ) Tile Profile Weight-W (Ibf) Length-1 (ft) Width-w (ft) Galena S anish 'S' Roof Tile 8.5 1.42 0.833 Table 2: Aerodynamic Multipliers -?L (ft) Tile Profile ?L (ft) Direct Deck Application Galena S anish 'S' Roof Tile 0.235 Table 3: Restoring Moments due to Gravity - Ms (ft-lbf) Tile 2":12" 3":12" 4":12" 5":12" VAT' 7":12" or Profile greater Galena Direct Direct Direct Direct Direct Direct Spanish Deck Deck Deck Deck Deck Deck 'S' Roof Tile 6.20 6.13 6.03 5.89 5.74 5.67 Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Mechanically Attached Systems Tile Profile Fastener Type Direct Deck min 15/32" plywood) Direct Deck min. 19/32" plywood) Galena 2-10d Ring Shank Nails 28.6 41.2 Spanish 'S' Roof Tile 1-10d Smooth or Screw Shank Nail 2 5.1 6.8 2-10d Smooth or Screw Shank Nails11 �.9 9.2 1 #8 Screw . 20.7 20.7 2 #8 Screw 43.2 43.2 1-10d Smooth or Screw Shank Nail Field Cli z 23.1 23.1 1-10d Smooth or Screw ,Shank Nail Eave Cli 29 3 29.3 2-10d Smooth or Screw Shank Nails Field Clip) 27.6 27.6 2-10d Smooth or Screw Shank Nails Eave Clip), 38.1 38.1 2710d Ring Shank Nails 33.1 48.1 1 Installation with a 4"tile headlap and fasteners are located a min. of 2'/2" from head of tile. 2 When using only one fastener use the hole that is approximately 4 %" away from ihtedocking edge. NOA No.: 14-0416.12 MAMMADECOUNTY ..., , Expiration Date: 11/18/19 Approval )gate: 11/27/14 Page 4 of 6 Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf) for Two Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Galena Spanish 'S' Roof Tile Adhesive 29.34 3 See manufacturer's component approval for installation requirements. 4 The Dow Chemical Company TileBond Average weight per patty 10.7 grams. 3W 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams. Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-lbf) for Single Patty Adhesive Set Systems Tile Profile Tile Application Minimum Attachment Resistance Galena Spanish 'S' Roof 3M'" 2-Component Foam Roof Tile Adhesive AH-160 66.55 Tile 3M " 2-Component Foam Roof Tile Adhesive AH-160 38.7 5 5 Large paddy placement of 63 grams of 3M- 2-Component Foam Roof Tile Adhesive AH-160. 6 Medium paddy placement of 27 grams of 3M— 2-Component Foam Roof Tile Adhesive AH-160. Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf) for Mortar or Adhesive Set Systems Tile Tile Application Minimum Attachment Profile Resistance Galena Spanish 'S' Roof Tile Mortar Set 24.5 5. LABELING All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following statement: "Miami -Dade County Product Control Approved". OR GALENA SPANISH "S" CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE) NOA No.: 14-0416.12 Expiration Date: 11/18/19 Approval Date: 11/27/14 Page 5 of 6 6. BUILDING PERMIT REQUIREMENTS: 6.1 Application for building permit shall be accompanied by copies of the following: 6.1.1 This Notice of Acceptance. 6.1.2 Any other documents required by Building Official or Applicable building code in order to properly evaluate the installation of this system. PROFILE DRAWINGS GALENA.SPANISH "S" CONCRETE ROOF TILE END OF THIS ACCEPTANCE NOA No.: 14-0416.12 Expiration Date: 11/18/19 Approval Date: 11/27/14 Page 6 of 6 RECEIVED APR } 7 :'19 5T. Lucie County, Permitting J MIAMI-DARE COUNTY EM M1�F�1 ODUCT CONTROL SECTION SCANNEB� it 505 $W 26 Str9ot, Room 209 DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BY Miami, Florida 33175-2474 BOARD AND CODE ADMINISTRATION DIVISION St. Lucie CoUr"11)315.2590 F (786) 315-2599 NOTICE OF ACCEPTANCE CNOA) www.miamidade..eov/economy ICP Adhesives and Sealants, Inc. 12505 NW 44`4 Street Coral Springs, FL. 33065 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the A13J may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the Florida Building Code including the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: ICP Adhesives Polyset® AH-160 LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall be cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA renews NOA 16-0315.01 and consists of pages I through 11. The submitted documentation was reviewed by Alex Tigera. L77APPROVED NOA No.:17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 1 of 11 ROOFING COMPONENT APPROVAL: Category: Roofing Sub Category: Roof tile adhesive Materials: Polyurethane SCOPE: This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP Adhesives Polyse& AH-160. PRODUCTS MANUFACTURED BY APPLICANT: Product Dimensions Test Specifications ICP Adhesives N/A TAS 101 Polyset®AH-160 ICP Adhesives Foam N/A Dispenser RTF1000 ICP Adhesives ProPack® N/A 30 & 100 Product Descriution Two component polyurethane foam adhesive Dispensing Equipment Dispensing Equipment PRODUCTS MANUFACTURED BY OTHERS: Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment resistance values with the use of ICP Adhesives Polysee AH-160 rooftile adhesive. MANUFACTURING LOCATION: Tomball, TX. PHYSICAL PROPERTIES: Prove Test Density ASTM D 1022 Compressive Strength ASTM D 1621 Tensile Strength ASTM D 1623 Water Absorption ASTM D 2,127 Moisture Vapor Transmission ASTM E 96 Dimensional Stability ASTM D 2126 Closed Cell Content ASTM D 2856 Results 1.6 lbs./ft 3 18 PSI Parallel to rise 12 PSI Perpendicular to rise 28 PSI Parallel to rise 0.08 Lbs./Ftz 3.1 Perm / Inch +0.07% Volume Change @ 40° F., 2 weeks +6.0% Volume Change @1580F., 100% Humidity, 2 weeks 86% Note: The physical properties listed above are presented as typical average values as determined by accepted ASTM test methods and are subject to normal manufacturing variation. MIAM O=E COUNTY NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 2 of 11 EVIDENCE SUBM1TTEp: Test Aeencv Test Identifier Test Name/Report Date' Center for Applied Engineering #94-060 TAS 101 04/08/94 257818-IPA TAS 101 12/10/96 25-7438-3 SSTD 11-93 10/25/95 25-7438-4 25-7438-7 SSTD 11-93 11/02/95 25-7492 SSTD 11-93 12/12/95 Miles Laboratories NB-5$9-631 ASTM D 1623 02/01/94 Polymers Division Ramtech Laboratories, Inc. 9637-92 ASTM E 108 04/30/93 Southwest Research Institute 01-6743-011 ASTM E 108 11/16/94 01-6739-062b[1] ASTM F 84 01/16/95 Trinity Engineering 7050.02.96-1 TAS 114 03/14/96 P36700.04.12 ASTM D 1623 04/18/12 P39740.02.12 TAS 101 02/21/12 TAS 123 Celotex Corp. Testing Services 528454-2-1 TAS 101 10/23/98 528454-9-1 528454-10-1 520109-1 TAS 101 12/28/98 520109-2 520109-3 520109-6 520109-7 520191-1 TAS 101 03/02/99 520109-2-1 LIMITATIONS: 1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating. 2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles. 3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120. 4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset° AH-160 roof tile adhesive with their tile assemblies shall test in accordance with TAS 101. 5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and Rule 61 G20-3 of the Florida Administrative Code. MIAMFDADECOUN Y NOA No.: 17-0322.03 Expiration Date: 05110/22 Approval Date: 04/27/17 Page 3 of 11 INSTALLATION: I. ICP Adhesives Polyset® AH-160 maybe used with any roof tile assembly having a current NOA that lists attachment resistance values with the use of ICP Adhesives Polyset® AH-160. 2. ICP Adhesives Polysete AH-160 shall be applied in compliance with the Component Application section and the corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP Adhesives Polysete AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive attachment data is noted in the roof file assembly NOA. 3. ICP Adhesives Polysete AH-160 and its components shall be installed in accordance with Roofing Application Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet. 4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having jurisdiction. 5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between 1.0-1.15 (A): 1.0 (B). 6. ICP Adhesives Polyset' AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP . Adhesives ProPack' 30 & 100 dispensing equipment only. 7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight. 8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives Polyset' AH-160 has been dispensed. 9. ICP Adhesives Polyset' AH-160 placement and minimum patty weight shall be in accordance with the 'Placement Details' herein. Each generic tile profile requires the specific placement noted herein. MIAMMADECOUNrY NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 4 of 11 Table 1: Adhesive Placement For Each Generic Tile Profile Tile Profile Placement Detail Minimum Paddy Contact Minimum Paddy Gram Area Weight have Course -Flat, Low, High Profiles All Eave Course 17-23 sq. inches 45-65 Flat, Low, High Profiles 91 17-23 sq. inches 45-65 Flat Profile #2 10-12 sq. inches 30 Low Profile #2 12-14 sq. inches 30 High Profile 42 17-19 sq. inches 30 Flat, Low, High Profiles #3 Two Paddys: 8-9 sq. inches at 12 grams per paddy head of tile 9-11 sq. inches at overlap Two -Piece Barrel (Cap Tile) Two Piece 2 Beads (1 each longitudinal 17 grams per bead edge) 20-25 sq. inches each bead Two Piece Barrel (Pan Tile) Two Piece 65-70 sq. inches 34 grams under pan LABELING: All approved products listed herein shall be labeled and shall bear the imprint or identifiable marldng of the manufacturer's name or logo and folldwing statement: "Miami -Dade County Product Control Approved" or the Miami - Dade County Product Control Seal as shown below. %eaAcmm BUILDING PERMIT REQUIREMENTS: As required by the Building Official or applicable building code in order to properly evaluate the installation of this system. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 5 of 11 osatw. APPROVED ADHESIVE PLACEMENT DETAIL # 1 Flat/Low Profile Tile I. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib closest to the overlock of the the being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm)-23 (148.4 cm') square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the cave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. High Profile / Single Pan Tile 1. Starting at the Gave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 2. Continue in same manner. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27117 Page 6 of 11 ADHESIVE PLACEMENT DETAIL # 2 F*W* APPROVED Flat/Low Profile Tile Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib of the tile closest to the Overlock of the file being set. Insure approximately 17 (109.7 omz) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7' (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the strengthening rib closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 10" (64.5 cmz) -12 (77.4 cmz) square inch adhesive contact with the underside of the tile. Medium Profile / Double Pan Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 ram) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. Insure approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. Insure approximately 12" (77.4 cm2) - 14 (90.3 cmz) square inch adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.:17-0322.03 Expiration Date: 0511022 Approval Date: 0427/17 Page 7 of 11 APPROVED ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED) High Profile / Single Pan Tile I . Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x I" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlook of the tile being set. Inspre approximately 17 (109.7 cm2) — 23 (148.4 cm2) square inch adhesive contact with the underside of the tile. 2. At the second course, apply a minimum 2" (50.8mm) x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under the pan portion of the tile closest to the overlock of the tile being set. 3. Continue in same manner. lnsure approximately 17" (109.7 cm2) - 19 (122.6 cm2) square inch adhesive contact with the underside of the tile. NOA No.:17-0322.03 Expiration Date: 05/1042 Approval Date: 04/27/17 Page 8 of 11 ADHESIVE PLACEmlENT DETAIL # 3 im Flatlt.awProffieRlle MG&Um N8111ene APPROVED On the eave course only, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown, under the strengthening rib for flat file or under the pan portion of the tile for low or high profile tile closest to the overtock of the tile being set. Leave approximately 4" (101.6 mm) up from the eave edge free of foam to prevent the expanded adhesive from blocking the weep holes. Insure approximately 17-23 in' (109.7-148.4 cm2) of adhesive contact with the underside of the tile 2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4 mm) foam paddy onto the underlayment just below the second course line positioned foam paddy Under the strengthening rib for flat tile, or under the pan portion of the tile, closest to the underlock for the second course the to be installed. Insure approximately 8-9 0 (51.6-58.1 cmz) of adhesive contact with the underside of the tile. (Instructions continued on next page) NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27117 Page 9 of 11 ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED) Hisb Praft7ne Also apply a 2" (50.8 mm) x 4" (101.6 mm) x W (19 mm) paddy on top of the eave course file surface as shown, on top of the strengthening rib for flat tile or on top of the pan portion of the tile, closest to the underlock of the fast course of tile. Install second course of tile. Insure approximately 9 (58.1 cmt) - 11 (7lem=) square inch adhesive contact with the underside of the file at the overlap and 7 (45.2 cm2) - 9 (58.1 ce) square inch adhesive contact with the underside of the tile at the head of the tile. Continue in same manner. NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 10 of 11 A )mivE PLACEMENT DETAIL TWO PIECE BARREL 'q Plate enw9h ad hesive to achieve 65 to 7a Immntaawdhthe pantile: Remove tappo,uon oftheeaveioersetove UWAb&tt.,e ndtwnm of Pan 61MEn MOaVemdofpanandmverfiWSr"=hateaveiFne. 7tvo Piece Barrel -High Profile,Yile APPROVED Two Piece Barrel (Cap and Pan) Tile 1. Starting at the eave course, apply a minimum 2" (50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy onto the underlayment positioned as shown under two adjacent pan tiles. Support eave tiles from rocldng until adhesive has a chance to cure. 2. Continue in same manner bringing two pan courses up toward the ridge. Insure approximately 65 (419.4 cm) — 70 (451.6 cm2) square inch adhesive contact with the underside of the pan tile. 3. Turn covers upside down exposing the underside of the tile. Apply a minimum 1" (25.4 mm) x 10" (254 mm) bead of adhesive directly on the inner edge of each side of the cover tile. Leave approximately 3/4" (19 mm) to 1" (25.4 mm) from the outside edge of the tile, inward, free of foam to allow for expansion. 4. Turn cover tile over after foam is applied and place onto pan file course. Insure a minimum of 20 (129 etn2) -25 (161.3 em2) square inch contact area on each side of the cover tile to the pan tile. Continue in same manner. Trim away any cured exposed foam adhesive. Pointing of longitudinal edges of the cover tiles are considered optional. 5. When additional nailing is required, 2" (50.8 mm) x 4" (101.6 mm) milers or the tie wire system psing galvanized, stainless steel, or copper wire and compatible nails may be used. END OF TMS ACCEPTANCE NOA No.: 17-0322.03 Expiration Date: 05/10/22 Approval Date: 04/27/17 Page 11 of 11