HomeMy WebLinkAboutNOAMIMI M
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER)
BOARD AND CODE ADMINISTRATION DIVISION
NOTICE OF ACCEPTANCE (VOA)
Entegra Roof Tile, LLC
1289 NE 9"' Ave
Okeechobee, FL. 34972
MIAMI-DADE COUNTY
SCANNEI RODUCT CONTROL SECTION
11805 SW 26 Street, Room 208
By Miami, Florida 33175-2474
St. Lucie Couf4t�786)315-2s90 F (786) 315-2599
www.miamidade.eov/economy
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this
product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted
manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or
suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance,
if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the
requirements of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: Galena Spanish "S" Concrete Roof Tile
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product,
for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section
of this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This renews and revises NOA 10-0518.04 and consists of pages 1 through 6.
The submitted documentation was reviewed by Juan E. Collao, R.A.
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 1 of 6
ROOFING ASSEMBLY APPROVAL
Category: Roofing
Sub -Category: Roofing Tiles
Material: Concrete
1. SCOPE
This approves a roofing system using Galena Spanish "S" Concrete Roof Tile, as manufactured by Entegra Roof
Tile, LLC as described in Section 2 of this Notice of Acceptance, designed to comply with the Florida Building Code
for High Velocity Hurricane Zone. For the locations where the pressure requirements, as determined by applicable
Building Code, does not exceed the design pressure values obtain by calculations in compliance with RAS 127 using
the values listed in section 4 herein. The attachment calculations shall be done as a moment based system.
2. PRODUCT DESCRIPTION
Manufactured by
Test Product
Applicant
Dimensions
Specifications Description
Oalena Spanish `S' Roof
L = 17"
TAS 112 High profile, interlocking, one-piece, "S"
Tile
W = 10"
shaped, concrete roof tile equipped with
H = 2.7"
two nail holes. For direct deck or
Thickness: %"
battened nail -on, mortar or adhesive set
applications.
Trim Pieces
L = varies
TAS 112 Accessory trim, concrete roof pieces for
W = varies
use at hips, rakes, ridges and valley
Varying thickness
terminations. Manufactured for each tile
profile.
2.1. MANUFACTURING LOCATION
1. Okeechobee, FL
2.2. EVIDENCE SUBMITTED
Test Agency
Test Identifier
Test Name/Reyort Date
Redland Technologies
7161-03
Static Uplift Testing Dec. 1991
Appendix III
PA 102 & PA 102(A)
Redland Technologies
7161-03
Wind Tunnel Testing Dec. 1991
Appendix II
PA 108 (Nail -On)
Redland Technologies
P0647-01
Wind Tunnel Testing Aug. 1994
PA 108 (Mortar Set)
Redland Technologies
P0402
Withdrawal Resistance Testing of Sept. 1993
screw vs. smooth shank nails
The Center for Applied
94-084
Static Uplift Testing May 1994
Engineering, Inc.
PA 101 (Mortar Set)
The Center for Applied
94-083
Static Uplift Testing April 1994
Engineering, Inc.
PA 161 (Adhesive Set)
NOA No.: 14-0416.12
MAMI•DADE COUNTY Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 2 of 6
Test Agency
The Center for Applied
Engineering, Inc.
The Center for Applied
Engineering, Inc.
Redland Technologies
The Center for Applied
Engineering, Inc.
Nutting Engineering
Celotex Corporation Testing
Service
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Walker Engineering, Inc.
Test Identifier
25-7183-4
25-7214-3
Letter Dated Aug. 1,
1994
Project No. 307025
Test #MDC-78
13343.1
520111-3
520191-2-1
Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Evaluation Calculations
Calculations
American Test Lab of South RT0624.04-14
Florida
I LIMITATIONS
3.1 Fire classification is not part of this acceptance.
Test Name/Report
Static Uplift Testing
PA 102 (2 Quik-Drive Screws, Direct
Deck)
Static Uplift Testing
PA 102 (1 Quik-Drive Screw, Direct
Deck)
Wind Tunnel Testing
PA 108 (Nail -On)
Wind Driven Rain
PA 100
Physical Properties
TAS 112
Static Uplift Testing
PA 101
Two Patty Adhesive Set System
25-7094
25-7496
25-7584
25-7804b-8
25-7804-4 & 5
25-7848-6
25-7183
Restoring Moment Due to Gravity
Aerodynamic Multiplier
TAS 112
Date
Feb. 1995
March, 1995
Aug. 1994
Oct. 1994
June 2007
Dec. 1998
March 1999
April 1999
February 1996
April 1996
December 1996
March 1995
09/14/09
09/14/09
07/07/14
3.2 For mortar or adhesive set tile applications, a static field uplift test shall be performed in accordance with
TAS 106.
3.3 Applicant shall retain the services of a Miami -Dade County Certified Laboratory to perform quarterly test
in accordance with TAS 112, appendix `A'. Such testing shall be submitted to the Miami -Dade Product
Control office for review.
3.4 Minimum underlayment shall be in compliance with the applicable Roofing Applications Standards listed
section 4.1 herein.
3.5 30/90 hot mopped underlayment applications may be installed perpendicular to the roof slope unless stated
otherwise by the underlayment material manufacturers published literature.
3.6 This acceptance is for wood deck applications. Minimum deck requirements shall be in compliance with
applicable building code.
3.7 All products listed herein shall have a quality assurance audit in accordance with the Florida Building
Code and Rule 61G20-3 of the Florida Administrative Code.
MAHMADE COUNTY NOA No.: 14-0416.12
[TIT. Imp Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 3 of 6
4. INSTALLATION
4.1 Galena Spanish "S" Concrete Roof Tile and its components shall be installed in strict compliance with
Roofing Application Standard RAS 118, RAS 119 and RAS 120.
4.2 Data For Attachment Calculations
Table 1: Average Weight (W) and Dimensions (I x w )
Tile Profile
Weight-W (Ibf)
Length-1 (ft)
Width-w (ft)
Galena S anish 'S' Roof Tile
8.5
1.42
0.833
Table 2: Aerodynamic Multipliers -?L (ft)
Tile
Profile
?L (ft)
Direct Deck Application
Galena S anish 'S' Roof Tile
0.235
Table 3: Restoring Moments due to Gravity - Ms (ft-lbf)
Tile
2":12"
3":12"
4":12"
5":12"
VAT'
7":12" or
Profile
greater
Galena
Direct
Direct
Direct
Direct
Direct
Direct
Spanish
Deck
Deck
Deck
Deck
Deck
Deck
'S' Roof
Tile
6.20
6.13
6.03
5.89
5.74
5.67
Table 4: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Mechanically Attached Systems
Tile
Profile
Fastener Type
Direct Deck
min 15/32" plywood)
Direct Deck
min. 19/32" plywood)
Galena
2-10d Ring Shank Nails
28.6
41.2
Spanish 'S'
Roof Tile
1-10d Smooth or Screw
Shank Nail 2
5.1
6.8
2-10d Smooth or Screw
Shank Nails11
�.9
9.2
1 #8 Screw .
20.7
20.7
2 #8 Screw
43.2
43.2
1-10d Smooth or Screw
Shank Nail Field Cli z
23.1
23.1
1-10d Smooth or Screw
,Shank Nail Eave Cli
29 3
29.3
2-10d Smooth or Screw
Shank Nails Field Clip)
27.6
27.6
2-10d Smooth or Screw
Shank Nails Eave Clip),
38.1
38.1
2710d Ring Shank Nails
33.1 48.1
1 Installation with a 4"tile headlap and fasteners are located a min. of 2'/2" from head of tile.
2 When using only one fastener use the hole that is approximately 4 %" away from ihtedocking edge.
NOA No.: 14-0416.12
MAMMADECOUNTY
..., , Expiration Date: 11/18/19
Approval )gate: 11/27/14
Page 4 of 6
Table 5: Attachment Resistance Expressed as a Moment Mr (ft-lbf)
for Two Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment Resistance
Galena Spanish 'S' Roof Tile
Adhesive
29.34
3 See manufacturer's component approval for installation requirements.
4 The Dow Chemical Company TileBond Average weight per patty 10.7 grams.
3W 2-Component Foam Roof Tile Adhesive AH-160, average weight per patty 8 grams.
Table 6: Attachment Resistance Expressed as a Moment - Mr (ft-lbf)
for Single Patty Adhesive Set Systems
Tile
Profile
Tile Application
Minimum Attachment
Resistance
Galena Spanish 'S' Roof
3M'" 2-Component Foam Roof Tile Adhesive AH-160
66.55
Tile
3M " 2-Component Foam Roof Tile Adhesive AH-160
38.7 5
5 Large paddy placement of 63 grams of 3M- 2-Component Foam Roof Tile Adhesive AH-160.
6 Medium paddy placement of 27 grams of 3M— 2-Component Foam Roof Tile Adhesive AH-160.
Table 7: Attachment Resistance Expressed as a Moment - Mf(ft-lbf)
for Mortar or Adhesive Set Systems
Tile
Tile Application
Minimum Attachment
Profile
Resistance
Galena Spanish 'S'
Roof Tile
Mortar Set
24.5
5. LABELING
All tiles shall bear the imprint or identifiable marking of the manufacturer's name or logo as seen below or following
statement: "Miami -Dade County Product Control Approved".
OR
GALENA SPANISH "S" CONCRETE ROOF TILE LABEL (LOCATED ON UNDERSIDE OF TILE)
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 5 of 6
6. BUILDING PERMIT REQUIREMENTS:
6.1 Application for building permit shall be accompanied by copies of the following:
6.1.1 This Notice of Acceptance.
6.1.2 Any other documents required by Building Official or Applicable building code in order to properly
evaluate the installation of this system.
PROFILE DRAWINGS
GALENA.SPANISH "S" CONCRETE ROOF TILE
END OF THIS ACCEPTANCE
NOA No.: 14-0416.12
Expiration Date: 11/18/19
Approval Date: 11/27/14
Page 6 of 6
RECEIVED
APR } 7 :'19
5T. Lucie County, Permitting J MIAMI-DARE COUNTY
EM
M1�F�1 ODUCT CONTROL SECTION
SCANNEB� it 505 $W 26 Str9ot, Room 209
DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) BY Miami, Florida 33175-2474
BOARD AND CODE ADMINISTRATION DIVISION St. Lucie CoUr"11)315.2590 F (786) 315-2599
NOTICE OF ACCEPTANCE CNOA) www.miamidade..eov/economy
ICP Adhesives and Sealants, Inc.
12505 NW 44`4 Street
Coral Springs, FL. 33065
SCOPE:
This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The
documentation submitted has been reviewed and accepted by Miami -Dade County RER -Product Control Section to be
used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ).
This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section
(In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product
or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the
manufacturer will incur the expense of such testing and the A13J may immediately revoke, modify, or suspend the use
of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is
determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements
of the applicable building code.
This product is approved as described herein, and has been designed to comply with the Florida Building Code
including the High Velocity Hurricane Zone of the Florida Building Code.
DESCRIPTION: ICP Adhesives Polyset® AH-160
LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state and following
statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein.
RENEWAL of this NOA shall be considered after a renewal application has been filed and there has been no change
in the applicable building code negatively affecting the performance of this product.
TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the
materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for
sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of
this NOA shall be cause for termination and removal of NOA.
ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the
expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done
in its entirety.
INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and
shall be available for inspection at the job site at the request of the Building Official.
This NOA renews NOA 16-0315.01 and consists of pages I through 11.
The submitted documentation was reviewed by Alex Tigera.
L77APPROVED
NOA No.:17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 1 of 11
ROOFING COMPONENT APPROVAL:
Category: Roofing
Sub Category: Roof tile adhesive
Materials: Polyurethane
SCOPE:
This approves ICP Adhesives Polyset® AH-160 as manufactured by ICP Adhesives and Sealants, Inc. as described
in this Notice of Acceptance. For the locations where the design pressure requirements, as determined by applicable
building code, do not exceed the design pressure values obtained by calculations in compliance with Roofing
Application Standard RAS 127. For use with approved flat, low, and high profile roof tile systems using ICP
Adhesives Polyse& AH-160.
PRODUCTS MANUFACTURED BY APPLICANT:
Product Dimensions Test
Specifications
ICP Adhesives N/A TAS 101
Polyset®AH-160
ICP Adhesives Foam N/A
Dispenser RTF1000
ICP Adhesives ProPack® N/A
30 & 100
Product Descriution
Two component polyurethane foam adhesive
Dispensing Equipment
Dispensing Equipment
PRODUCTS MANUFACTURED BY OTHERS:
Any Miami -Dade County Product Control Accepted Roof Tile Assembly having a current NOA which list attachment
resistance values with the use of ICP Adhesives Polysee AH-160 rooftile adhesive.
MANUFACTURING LOCATION:
Tomball, TX.
PHYSICAL PROPERTIES:
Prove Test
Density ASTM D 1022
Compressive Strength ASTM D 1621
Tensile Strength
ASTM D 1623
Water Absorption
ASTM D 2,127
Moisture Vapor Transmission
ASTM E 96
Dimensional Stability
ASTM D 2126
Closed Cell Content ASTM D 2856
Results
1.6 lbs./ft 3
18 PSI Parallel to rise
12 PSI Perpendicular to rise
28 PSI Parallel to rise
0.08 Lbs./Ftz
3.1 Perm / Inch
+0.07% Volume Change @ 40° F., 2 weeks
+6.0% Volume Change @1580F., 100% Humidity, 2
weeks
86%
Note: The physical properties listed above are presented as typical average values as determined by
accepted ASTM test methods and are subject to normal manufacturing variation.
MIAM O=E COUNTY NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 2 of 11
EVIDENCE SUBM1TTEp:
Test Aeencv
Test Identifier
Test Name/Report
Date'
Center for Applied Engineering
#94-060
TAS 101
04/08/94
257818-IPA
TAS 101
12/10/96
25-7438-3
SSTD 11-93
10/25/95
25-7438-4
25-7438-7
SSTD 11-93
11/02/95
25-7492
SSTD 11-93
12/12/95
Miles Laboratories
NB-5$9-631
ASTM D 1623
02/01/94
Polymers Division
Ramtech Laboratories, Inc.
9637-92
ASTM E 108
04/30/93
Southwest Research Institute
01-6743-011
ASTM E 108
11/16/94
01-6739-062b[1]
ASTM F 84
01/16/95
Trinity Engineering
7050.02.96-1
TAS 114
03/14/96
P36700.04.12
ASTM D 1623
04/18/12
P39740.02.12
TAS 101
02/21/12
TAS 123
Celotex Corp. Testing Services
528454-2-1
TAS 101
10/23/98
528454-9-1
528454-10-1
520109-1
TAS 101
12/28/98
520109-2
520109-3
520109-6
520109-7
520191-1
TAS 101
03/02/99
520109-2-1
LIMITATIONS:
1. Fire classification is not part of this acceptance. Refer to the Prepared Roof Tile Assembly for fire rating.
2. ICP Adhesives Polyset® AH-160 shall solely be used with flat, low, & high tile profiles.
3. Minimum underlayment shall be in compliance with the Roofing Application Standard RAS 120.
4. Roof Tile manufactures acquiring acceptance for the use of ICP Adhesives Polyset° AH-160 roof tile adhesive
with their tile assemblies shall test in accordance with TAS 101.
5. All products listed herein shall have a quality assurance audit in accordance with the Florida Building Code and
Rule 61 G20-3 of the Florida Administrative Code.
MIAMFDADECOUN Y NOA No.: 17-0322.03
Expiration Date: 05110/22
Approval Date: 04/27/17
Page 3 of 11
INSTALLATION:
I. ICP Adhesives Polyset® AH-160 maybe used with any roof tile assembly having a current NOA that lists
attachment resistance values with the use of ICP Adhesives Polyset® AH-160.
2. ICP Adhesives Polysete AH-160 shall be applied in compliance with the Component Application section and the
corresponding Placement Details noted herein. The roof tile assembly's adhesive attachment with the use of ICP
Adhesives Polysete AH-160 shall provide sufficient attachment resistance to meet or exceed the resistance value
determined in compliance with Miami -Dade County Roofing Application Standards RAS 127. The adhesive
attachment data is noted in the roof file assembly NOA.
3. ICP Adhesives Polysete AH-160 and its components shall be installed in accordance with Roofing Application
Standard RAS 120, and ICP Adhesives and Sealants, Inc.'s Operating Instruction and Maintenance Booklet.
4. Installation must be by a Factory Trained 'Qualified Applicator' approved and licensed by ICP Adhesives and
Sealants, Inc. ICP Adhesives and Sealants, Inc. shall supply a list of approved applicators to the authority having
jurisdiction.
5. Calibration of the ICP Adhesives Foam Dispenser RTF 1000 dispensing equipment is required before application
of any adhesive. The mix ratio between the "A" component and the "B" component shall be maintained between
1.0-1.15 (A): 1.0 (B).
6. ICP Adhesives Polyset' AH-160 shall be applied with ICP Adhesives Foam Dispenser RTF1000 or ICP .
Adhesives ProPack' 30 & 100 dispensing equipment only.
7. ICP Adhesives Polyset' AH-160 shall not be exposed permanently to sunlight.
8. Tiles must be adhered in freshly applied adhesive. Tile must be set within 1 to 2 minutes after ICP Adhesives
Polyset' AH-160 has been dispensed.
9. ICP Adhesives Polyset' AH-160 placement and minimum patty weight shall be in accordance with the
'Placement Details' herein. Each generic tile profile requires the specific placement noted herein.
MIAMMADECOUNrY NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 4 of 11
Table 1: Adhesive Placement For Each Generic Tile Profile
Tile Profile
Placement Detail
Minimum Paddy Contact
Minimum Paddy Gram
Area
Weight
have Course -Flat, Low, High
Profiles
All Eave Course
17-23 sq. inches
45-65
Flat, Low, High Profiles
91
17-23 sq. inches
45-65
Flat Profile
#2
10-12 sq. inches
30
Low Profile
#2
12-14 sq. inches
30
High Profile
42
17-19 sq. inches
30
Flat, Low, High Profiles
#3
Two Paddys: 8-9 sq. inches at
12 grams per paddy
head of tile 9-11 sq. inches at
overlap
Two -Piece Barrel (Cap Tile)
Two Piece
2 Beads (1 each longitudinal
17 grams per bead
edge) 20-25 sq. inches each
bead
Two Piece Barrel (Pan Tile)
Two Piece
65-70 sq. inches
34 grams under pan
LABELING:
All approved products listed herein shall be labeled and shall bear the imprint or identifiable marldng of the
manufacturer's name or logo and folldwing statement: "Miami -Dade County Product Control Approved" or the Miami -
Dade County Product Control Seal as shown below.
%eaAcmm
BUILDING PERMIT REQUIREMENTS:
As required by the Building Official or applicable building code in order to properly evaluate the installation of this
system.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 5 of 11
osatw.
APPROVED
ADHESIVE PLACEMENT DETAIL # 1
Flat/Low Profile Tile
I. Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown,
under the strengthening rib closest to the overlock
of the the being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm)-23 (148.4 cm') square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the cave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
High Profile / Single Pan Tile
1. Starting at the Gave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as shown
under the pan portion of the tile closest to the
overlock of the tile being set.
2. Continue in same manner. Insure approximately 17
(109.7 cm2) — 23 (148.4 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27117
Page 6 of 11
ADHESIVE PLACEMENT DETAIL # 2
F*W*
APPROVED
Flat/Low Profile Tile
Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
strengthening rib of the tile closest to the Overlock of
the file being set. Insure approximately 17 (109.7 omz)
— 23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7' (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the
strengthening rib closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 10"
(64.5 cmz) -12 (77.4 cmz) square inch adhesive
contact with the underside of the tile.
Medium Profile / Double Pan Tile
1. Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 ram) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlock of the
tile being set. Insure approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. Insure approximately 12"
(77.4 cm2) - 14 (90.3 cmz) square inch adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.:17-0322.03
Expiration Date: 0511022
Approval Date: 0427/17
Page 7 of 11
APPROVED
ADHESIVE PLACEMENT DETAIL # 2 (CONTINUED)
High Profile / Single Pan Tile
I . Starting at the eave course, apply a minimum 2" (50.8
mm) x 10" (254 mm) x I" (25.4 mm) foam paddy
onto the underlayment positioned as shown under the
pan portion of the tile closest to the overlook of the
tile being set. Inspre approximately 17 (109.7 cm2) —
23 (148.4 cm2) square inch adhesive contact with the
underside of the tile.
2. At the second course, apply a minimum 2" (50.8mm)
x 7" (177.8 mm) x 1" (25.4 mm) foam paddy onto the
underlayment positioned as shown under the pan
portion of the tile closest to the overlock of the tile
being set.
3. Continue in same manner. lnsure approximately 17"
(109.7 cm2) - 19 (122.6 cm2) square inch adhesive
contact with the underside of the tile.
NOA No.:17-0322.03
Expiration Date: 05/1042
Approval Date: 04/27/17
Page 8 of 11
ADHESIVE PLACEmlENT DETAIL # 3
im
Flatlt.awProffieRlle
MG&Um N8111ene
APPROVED
On the eave course only, apply a minimum 2" (50.8
mm) x 10" (254 mm) x 1" (25.4 mm) foam paddy
onto the underlayment positioned as shown, under
the strengthening rib for flat file or under the pan
portion of the tile for low or high profile tile closest
to the overtock of the tile being set. Leave
approximately 4" (101.6 mm) up from the eave
edge free of foam to prevent the expanded adhesive
from blocking the weep holes. Insure
approximately 17-23 in' (109.7-148.4 cm2) of
adhesive contact with the underside of the tile
2. Apply a 4" (101.6 mm) x 4" (101.6 mm) x 1 " (25.4
mm) foam paddy onto the underlayment just below
the second course line positioned foam paddy
Under the strengthening rib for flat tile, or under the
pan portion of the tile, closest to the underlock for
the second course the to be installed. Insure
approximately 8-9 0 (51.6-58.1 cmz) of adhesive
contact with the underside of the tile.
(Instructions continued on next page)
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27117
Page 9 of 11
ADHESIVE PLACEMENT DETAIL # 3 (CONTINUED)
Hisb Praft7ne
Also apply a 2" (50.8 mm) x 4" (101.6 mm) x W
(19 mm) paddy on top of the eave course file
surface as shown, on top of the strengthening rib
for flat tile or on top of the pan portion of the tile,
closest to the underlock of the fast course of tile.
Install second course of tile. Insure approximately
9 (58.1 cmt) - 11 (7lem=) square inch adhesive
contact with the underside of the file at the overlap
and 7 (45.2 cm2) - 9 (58.1 ce) square inch
adhesive contact with the underside of the tile at
the head of the tile. Continue in same manner.
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 10 of 11
A )mivE PLACEMENT DETAIL
TWO PIECE BARREL
'q Plate enw9h ad hesive to achieve 65 to 7a
Immntaawdhthe pantile:
Remove tappo,uon oftheeaveioersetove UWAb&tt.,e ndtwnm of
Pan 61MEn MOaVemdofpanandmverfiWSr"=hateaveiFne.
7tvo Piece Barrel -High Profile,Yile
APPROVED
Two Piece Barrel (Cap and Pan) Tile
1. Starting at the eave course, apply a minimum 2"
(50.8 mm) x 10" (254 mm) x 1" (25.4 mm) foam
paddy onto the underlayment positioned as
shown under two adjacent pan tiles. Support eave
tiles from rocldng until adhesive has a chance to
cure.
2. Continue in same manner bringing two pan
courses up toward the ridge. Insure
approximately 65 (419.4 cm) — 70 (451.6 cm2)
square inch adhesive contact with the underside
of the pan tile.
3. Turn covers upside down exposing the underside
of the tile. Apply a minimum 1" (25.4 mm) x 10"
(254 mm) bead of adhesive directly on the inner
edge of each side of the cover tile. Leave
approximately 3/4" (19 mm) to 1" (25.4 mm)
from the outside edge of the tile, inward, free of
foam to allow for expansion.
4. Turn cover tile over after foam is applied and
place onto pan file course. Insure a minimum of
20 (129 etn2) -25 (161.3 em2) square inch
contact area on each side of the cover tile to the
pan tile. Continue in same manner. Trim away
any cured exposed foam adhesive. Pointing of
longitudinal edges of the cover tiles are
considered optional.
5. When additional nailing is required, 2" (50.8
mm) x 4" (101.6 mm) milers or the tie wire
system psing galvanized, stainless steel, or
copper wire and compatible nails may be used.
END OF TMS ACCEPTANCE
NOA No.: 17-0322.03
Expiration Date: 05/10/22
Approval Date: 04/27/17
Page 11 of 11