HomeMy WebLinkAboutCALCULATIONS FOR HEAT LOSS - HEAT GAINResidential
In accordance
4/9/2019
Report Prepared By: SCANNED
Central Air Systems Inc. BY
St. Lucie County
For. {ADWARO HOLLOWAY
138 nETTLES BLVD
JENSEN BEACH,11
Design Conditions: Fort Pierce
Indoor: Outdoor:
Summer temperature: 70 Summer temperature: 90
Winter temperature: 70 Winter temperature: 42
Relative humidity: 55 Summer grains of moisture: 127
Daily temperature rangeMedium
Building Component Sensible Latant Total Total
Gain Gain Heat Gain Heat Loss
(BTUH) (BTUH) (BTUH) (BTUH)
Skylights 0 0 0 0
Whole House 16,791 5,028 20,819 14,655
(1.5 tons )
HVAC-Caic Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101