Loading...
HomeMy WebLinkAboutHOME INSTALLATION SPECSManufactured Home Installation Specifications (Must be completed and submitted with your application) Applicant HOWARD HOLLOWAY Address 138 Nettles BLVD JENSEN BEACH, FL Permit # Manufacturers Name JACOBSEN Roof Zone Wind Zone 3 No. of Sections 2 Width 20 Length 35/39 Year 2019 Installation Standard Used (check) Manufacturers Manual YES 15C-1 _ Site Preparation Debris and Organic Removal YES Water Drainage: Natural Foundation Swale Pad YES Other Load bearing soil density 1500 Or assumed 1,000 psf Footing type: Poured in place Portable YES Mainrail frame block: Size 17X22.5 Placement o.c. Perimeter blocking: Size 16X16 Number Location Ridge beam support: Number Size Location Center line blocking: Number Size Location Special supports required (fireplace, bay window) Yes _ No X Mating of Units: Mating gasket FACTORY Type used FOAM Fasteners: Roof Type GALV Spacing o.c. Endwall Type LAG 6" Spacing 24" 0.0. Floors Type LAG 6" Spacing 24" O.C. Anchors: Type 6,000 3,150 Height of Unit (top of foundation to frame): Angle of straps 45 Number of frame ties 20 Spacing 4 O.C. Number of over -roof ties (if required) Number of sidewall anchors 20 Zone II Zone 11I Number of centerline anchors 20 Number of stabilizers Vents required forunderp�{ninning,(lsfl150 sf floor area): No. (� Prepared by: I X�` 40'� SCANNED BY St. Lucie County Serial # Page # Page # Page 4. Page #. Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Page # Date -� k' Revised 722/2014