Loading...
HomeMy WebLinkAboutREVISED INSTALLATION INSTRUCTION2 • (B00) 284-7437 • www.olivertechnologies.com • Fax (931) 796-8811 lr SCANNED OLIVER TECHNOLOGIES, INC. BY INSTALLATION INSTRUCTIONS FOR FLORIDA St. Lucie County MODEL 1101 11V11 SERIES ALL STEEL FOUNDATION SYSTEM PAN & CONCRETE (revision 5118) PATENT#i 6634150 & OTHER PATENT PENDING E ISED GER of 8:31 am, fY]ifl8 E WED BySf of B:]] am, 8Rf/18 •••tlrlrt:lll/ ' • o. 0242 Q STATE OF ; !r !l4fr 1]Ir•••• Aug 24, 2018 OLIVER TECHNOLOGIES, INC. FLORIDA INSTALLATION INSTRUCTIONS FORTHE MODEL 1101 "V" SERIES ALL STEEL FOUNDATION SYSTEM MODEL 1101 "V" (Steps 1-14) LONGITUDINAL ONLY: Follow Steps 1-9 LATERAL ONLY: Follow Steps 1-3 and Steps 10-14 ENGINEERS STAMP FOR CONCRETE APPLICATIONS: Follow Steps 15-18 ENGINEERS STAMP 1. SPECIAL CIRCUMSTANCES: If the following conditions occur - STOP! Contact Oliver Technologies at 1-800-284-7437: a) Pier height exceeds 48" c) Roof eaves exceed 16" e) Location is within 1500 feet of coast b) length of home exceeds 76' d) Sidewall height exceed 96" INSTALLATION OF GROUND PAN 2. Remove weeds and debris in an approximate two foot square to expose firm soil for each ground pan C) . 3. Place ground pan (C) directly below chassis I-beam. Press or drive pan firmly into soil until flush or below soil then install pier per manufacturer's instructions or per Florida Regs. �, SPECIAL NOTE: The longitudinal "V" brace system may also serve as a pier under the home and shoullbe.loaded as any other pier. It is recommended that after leveling piers, and one-third inch (1/3") before home is low`ered`comp etely on to piers, complete steps 4 through 9 below then remove jacks. 4� INSTALLATION OF LONGITUDINAL "V" BRACE SYSTEM (MOdel''11101 L "V'J NOTE: WHEN INSTALDNGTHE LONGITUDINAL SYSTEM ONLY, A MINIMUM OF 25YSTEMS PER FLOOR SECTION IS REQUIRED. SOILTEST PROBE SHOULD BE USEDTO DETERMINE CORRECTTYPE OF ANCHOR PER SOIL CLASSIFICATION. IF PROBE TEST READINGS ARE BETWEEN 175 & 275 A 5 FOOT ANCHOR MUST BE USED. IF PROBETEST READINGS ARE BETWEEN 276 & 350 A 4 FOOT ANCHOR MAYBE USED. USE GROUND ANCHORS WITH DIAGONALTIES AND STABILIZER PLATES EVERY 54". VERTICALTIES ARE ALSO REQUIRED ON HOMES SUPPLIED WITH,�EIiTICALTIE CONNECTION POINTS (PER FLORIDA REG.). 4. Choose one of the approved longitudinal tube installations; either Dial ramlA or B.Then select the correct square tube (E) length from the diagram for appropriate pier height at support location or cut and- drill `1..5'squard tube to achieve appropriate length. PIER HEIGHT 1.25" 1.50" ) \� PEER HEIGHT 1.50" (40" Min. - 45" Max.) Tube Length Tube Length `, f4/j6"Diats52) hole (40" Min. - 60" Max.) Tube Length 7 3/4" to 25" 22" 18" ,r 24 3/4" to 321 /4" 32" 18.'_ :' 33" to 4l" 44" f 18.° 40" to 48" S4" 1 B E Diagram A 0 14" to 18" 20" 18" to 25" 28" 24" to 35" 39" 30" to 40" 44" - 36"to48" 54" - Diagram B S. Install (2) of the 1.50" square tubes (E) iritofthe: U" bracket (J), insert carriage bolt and leave nut loose for final adjustment. 6. Place I-beam connector (F) loosely on the botiom flange of the I-beam. 7. (For Diagram A installation) Slide the selected 1.25" tube (E) into a 1.50" tube (E) and attach to I-beam connectors (F) and fasten loosely with bolt and nut. (For Diagram B installation) Attach the selected 1.5"tubes (E) to the I-beam connectors (F) and fasten loosely with bolts and nuts. 8. Repeat steps 6 through 7 to create the "V" pattern of the square tubes loosely in place. 9. Using standard hand tools tighten all nuts and bolts. (For Diagram A installation only, secure 1.25" and 1 .50" tubes using four(4)1 /4"-14 x 3/4" self -tapping screws in pre -drilled holes.) _INSTALLATION OF LATERAL TELESCOPING TRANSVERSE ARM SYSTEM (Model 1101 T" V'7 THE MODEL 1101 "V" (LONGITUDINAL & LATERAL PROTECTION) ELIMINATES THE NEED FOR STABILIZER PLATES & FRAMETIES. NOTE: THE USE OF THIS SYSTEM REQUIRES VERTICAL TIES SPACED AT 5'4" FOUR FOOT (41 GROUND ANCHOR MAY BE USED EXCEPT WHERE THE HOME MANUFACTURER SPECIFIES DIFFERENT. 10. Install remaining vertical tie -down straps and 4' ground anchors per home manufacturer's instructions. NOTE: Centerline anchors to be sized according to soil torque condition. Any manufacturer's specifications for sidewall anchor loads in excess of 4,000 lbs. require a 5' anchor per Florida Code. 11. Select the correct square tube brace (H) length for set-up lateral transverse at support Iocation.The lengths come in either60" or 72" lengths. (With the 1.50" tube as the bottom tube, and the 1.25" tube as the inserted tube.) 12. Install the 1.50 transverse brace (H) to the ground pan connector (D) with bolt and nut. 13. Slide 1.25" transverse brace into the 1.50" brace and attach to adjacent I-beam connector (1) with bolt and nut 14. Secure 1.50" transverse arm to 1.25" transverse arm using four (4)1 /4" -14 x 3/4" self -tapping screws in pre -drilled holes. Pane I PATFNTS rAIAt Sn R nTHFR PATFNT PFNT1INr" Revision 08/23/1 E INSTALLATION USING CONCRETE RUNNER/ FOOTER 15. A concrete runner, footer or slab may be used in place of the steel ground pan. a) The concrete shall be minimum 2500 psi mix b) A concrete runner may be either longitudinal or transverse, and must be a minimum of 8" deep with a minimum width of 16 inches longitudinally or 18 inches transverse to allow proper distance between the concrete bolt and the edge of the concrete (see below). Q Footers must have minimum surface area of 441 sq. in. (Le. 21" square), and must be a minimum of 8" deep. d) If a full slab is used, the depth must be a 4" minimum. Special inspection of the system bracket installation is not required. Footers must allow for at least 4" from the concrete bolt to the edge of the concrete. NOTE: The bottom of all footings, pads, slabs and runners must be per local jurisdiction. LONGITUDINAL: (Model 1101 LC "V"1 16. When using Part# 1101-W-CPCA (wetset) simply install the bracket in runner/footer OR When installing in cured concrete use Part# 101-D-CPCA (dryset).The 1101 (dryset) CA bracket is attached to the concrete using (2) 5/8"x3" concrete wedge bolts (Simpson part # 5162300H 5/8" X 3" or Powers equivalent). Place the CA bracket in desired location. Mark bolt hole locations, then using a 5/8" diameter masonry bit, drill a hole to a minimum depth of 3". Make sure all dust and concrete is blown out ofthe holes. Place wedge bolts into drille holes, then place 1101 (dry set) CA bracket onto wedge bolts and start wedge bolt nuts.Take\aNhamm re and lightly drive the wedge bolts down by hitting the nut (making sure not to hit the top of threads on bolt). The sleeve of concrete wedge bolt needs to beat or below thl too of concrete. Complete by tightening nuts. r`;\, \\ 17. For wet set (part # 1101-W TACA) installation simply install the anchor bolt intoiunrierAboteri For dry set installation (part # 1101-D TACA mark bolt hole locations, then using a 5/8" diam. masonry bit. drill a hole to a minimum depth of 3" Make sure all dust and concrete is blown out of the hole. Place wedge bolts (Simpson part #S162300H 5/8" X 3" or Powe f�equivalent) into (D) concrete dry transverse connector and into drilled hole. If needed, take a hammer and lightl) diiye the wedge'bolts down by hitting the nut (making sure not to hit the top of threads on bolt), then remove the nut. The sleeve of concrete wedge bolt needs to be at or below the too of concrete. 18. When using part# 1101 CVW (wetset) or 1101 CVD (dryset), instalLpelr tke' s7. 18. Notes: 1. LENGTH OF HOUSE ISTHE ACTUAL BOX SIZE 2.[3—= LOCATION OFTRANSVERSEBRACING ONLY 3 ® = LOCATION OF LONGITUDINAVBRACING ONLY 4. K3-- =TRANSVERSE AND LONGITUDINAL LOCATIONS i ALL,WIDTHSANDLENGTHSUPTO52' ALL WIDTHS AN D LENGTHS OVER 52' TO 80" HOMES WITH 5/12 ROOF PITCH REQUIRE: PER FLORIDA REGULATIONS 6 systems for home lengths up to 52' and 8 systems for homes over 52' and up 80. PATENT# 6634150 & OTHER PATENT PENDING Page i Revision 08/23/1 E I-TranseA, I-Tranverse Arm. I -Beam Connector Pad #1101-D-TACA H-Tanrverse Arm Pad a11or- W-TACA not shown Top (1251 Bottom (I5) 1 Cement Block I I CMU -Pier Omitted I Omitted LFor Clarity D-Concrete Tansvers QFWClarity I J - PanTansverse Connector. y Connector \ C-Conoete5lab/ ° e - C-Ground Pan \ Footer Anchor Bolts Model # 1101 T "V" Model # 1101 TC W" Florida approved 4' ground anchors maybe used in all locations except where home manufacturerApecifications for sidewall straps are in excess of 4,000 lbs. These locations require a 5' anchor. Per Florida code. C = GROUND PAN / CONCRETE FOOTER OR RUNNER t D=GROUND PAN/ CONCRETE UBRACKETS TRANSVERSE CONNECTOR (connects with gra" des. 1/2Sz12"1/2"cardagebolt and nut) E =TELESCOPING V BRACE TUBE ASSEMBLY (1.5" TUBE BOTTOM AND 1.25" TUBE INSERT) - RR 1°5." BE F="V"BRACEI-BEAM CONNECTOR ASSEMBLY H =TELESCOPING TRANSVERSE ARM ASSEMBLY I =TRANSVERSE ARM I -BEAM CONNECTOR (connects with grade 5-1/2"x2 1 /2"carriage bolt and nut) J = V PAN BRACKET (connects with grade 5 -1/2"x 2" 1/20carriage bolt anI.dnut) 1-Transverse Arm, FBeam F- 'V'Brace l-Beam H-Transverse Arm Connectors /Tap Bottom(1.5 15') D - Pan Transverse Connector / Concrete Transverse Bracket C-Ground Pan— / Concrete Footer E-"V'Brace Tube i Pan V Bracket/ Concrete V Bracket 1 _ Model # 1101 "V" Parts 1101 D CPCA 8 Pad # 1107 W-CPCA..rsh . PATENT# 6634150 & OTHER PATENT PENDING Model # 1101 C W" Page 3 Revision 08/23/1 E )� cEKIRAt , HOME � 2 � ` � T 4 VERTICAL VINYL SKIRTING ( conponenta d installation -m p aACK 1y AT•TACMCM W/TFF 4 IrfcM ace kwS 16"^PAwr SNAM0;TO -MP SACK '%'MrWSCQGWZ AND PANEL avT3 V Ea T%1�r1�� 3.9 m4w-s tte Foo-r SECuRfig qP �ENTSS.A-rSow Tb 'MP SACK Amp 4b '7 RAID wt '$y waN SL4Eas 160 Oc 1 'ALL PANELS 4qr ACC64jeue ay , ,REDrovw6 iDPivObyT Awn PuLAjpj ` VP ON PAASEI.J WeTM 71IICq �IF SOSL 15 Si S 0210212018