HomeMy WebLinkAboutGENERAC PAPERWORKINCLUDES: • True Power`" Electrical Technology • Two Line LCD Multilingual Digital Evolution'" Controller (English/Spanish/ French/Portuguese) • Two Transfer Switch Options Available: 100 Amp, 16 Circuit Switch or 200 Amp Service Rated Smart Switch. See Page 4 for Details. SCANNED_ BY St. Lucie County GENERAC" MOMEM GUARDIAN SERIES Residential Standby Generators Air -Cooled Gas Engine Standby Power Rating Models G007036-0, G007037-0 (Aluminum - Bisque) - 16I W 60 Hz Model G007035-0 (Aluminum - Bisque) - 16 k4V 60 Hz tv1odels 0007039-0, G007038-0 (Aluminum - Bisque) - 20I VV 60 Hz Models G007043-1. G007042-1 (Aluminum - Bisque) - 22 kW 60 Hz ST.LUCIE COUNTY PLAN REVIEW • Electronic Governor BLDG: • System Status & Maintenance Interval LED DATE-* Indicators FLE • Sound Attenuated Enclosure DATE: • Flexible Fuel Line Connector PLUMB: • Direct -To -Dirt Composite Mounting Pad DATE: • Natural Gas or LP Gas Operation MECH: • 5 Year Limited Warranty DATE: • Capability to be installed within 18" (457 mm) of a building* e !' Us Q/'� ' 13110 Note: CUL certification ovvlyapplies to unbundled units and units packaged with limited circuit switches. Units packaged with the Smart Switch are UL cringed in the USA only. `Only it located away from doors, vandows and fresh air intakes, and unless othervose directed by local codes. FEATURES FILE Copy O INNOVATIVE ENGINE DESIGN & RIGOROUS TESTING are at the heart of Generac's O success in providing the most reliable generators possible. Generac's G-Force engine lineup offers added peace of mind and reliability for when you need it the most. The G-Force series engines are purpose built and designed to handle the rigors of extended run times in high temperatures and extreme operating conditions. O TRUE POWER— ELECTRICAL TECHNOLOGY: Superior harmonics and sine wave O form produce less than 5%Total Harmonic Distortion for utility quality power. This allows confident operegan of sensitive electronic equipment and micro -chip based appliances, such as variable speed HVAC systems. SOLID-STATE, FREQUENCY COMPENSATED VOLTAGE REGULATION: This state-0f-theaN power maximizing regulation system is standard on all Generac models. It provides optimized FAST RESPONSE to changing load conditions and MAXIMUM MOTOR STARTING CAPABILITY by electronically torque -matching the surge loads to the engine. Digital voltage regulation at ±1 X. SINGLE SOURCE SERVICE RESPONSE from Gen sox's extensive dealer network provides pads and service know-how for the entire unit, from the engine to the smallest electronic component. O TEST CRITERIA: O GENERAC TRANSFER SWITCHES: Long life and reliability are J PROTOTYPE TESTED d HEMA M6I-22 EVALUATION synonymous with GENERAC POWER SYSTEMS. One reason for this J SYSTEM TORSIONAL TESTED J MOTOR STARTING ABILRY confidence is that the GENERAC product line includes its own transfer systems and controls for total system compatibility. Lu GENERAC .>�: I— PROMISE �- �° ' GENERAC° 16/20/22 kW features and benefits Engine • Generac G-Force design Maximizes engine "breathing" for increased fuel efficiency. Plateau honed cylinder walls and plasma molyrings helps the engine run cooler, reducing oil consumption resulting in longer engine life. • "Spiny-lok" cast iron cylinder walls Rigid construction and added durability provide long engine life. - • Electronic ignition/spark advance These features combine to assure smooth, quick starting every time. • Full pressure lubrication system Pressurized lubrication to all vital bearings means better performance, less maintenance and longer engine life. Now featur- ing up to a 2 year/200 hour oil change interval. • Low oil pressure shutdown system Shutdown protection prevents catastrophic engine damage due to low oil. • High temperature shutdown Prevents damage due to overheating. Generator • Revolving field Allows for a smaller, light weight unit that operates 25% more efficiently than a revolving armature generator. • Skewed stator Produces a smooth output waveform for compatibility with electronic equipment. • Displaced phase excitation Maximizes motor starting capability. • Automatic voltage regulation Regulates the output voltage to xl% prevents damaging voltage spikes. • UL 2200 listed For your safety. ..•... , %b k: Transfer Switch (if applicable) • Fullyautomatic Transfers your vital electrical loads to theenergiied source of power. • NEMA 3R Can he installed inside or outside for maximbm`flexibility. • Remote mounting Mounts near your existing distribulion,panel lot simple, low-cost installation. Evolution"' Controls wJ. • Auto/Manual/Off illuminated buttons Selects the operating mode and provides easy, ata-glance status indication in any condition. • Two-line LCD multilingual display Provides homeowners easily visible logs of history, maintenance and events up to 50 occurrences. • Sealed, raised buttons Smooth, weather -resistant user interface for programming and operations. • Utility voltage sensing Constantly monitors utility voltage, setpoints 65%dropout, 80%pick-up, of standard voltage. • Generator voltage sensing Constantly monitors generator voltage to ensure the cleanest power delivered to the home. • Utility interrupt delay Prevents nuisance start-ups of the engine, adjustable 2-1500 seconds from the factory default setting of 5 seconds by a qualified dealer. • Engine warm-up Ensures engine is ready to assume the load, setpoint approximately 5 seconds. • Engine cool -down Allows engine to cool prior to shutdown, setpoint approximately l minute. • Programmable exercise Operates engine to prevent oil seal drying and damage between power outages by running the generalorfor 5 minutes every other week Also offers a selectable setting for weekly or monthly operation providing flexibility and potentially lower fuel costs to the owner. • Smart battery charger Delivers charge to the battery only when needed at varying rates depending on outdoor air temperature. Compatible with lead acid and AGM -style batteries. • Main line circuit breaker Protects generator from overload. • Electronic governor Maintains constant 60 Hz frequency. Unit • SAE weather protective enclosure Sound attenuated enclosures ensure quiet operation and protection against mother nature, withstanding winds up to 150 mph. Hinged key locking roof panel forsecurity. Lift -out front for easy access to all routine maintenance items. Electrostat- ically applied textured epoxy paint for added durability. • Enclosed critical grade muffler Quiet, critical grade muffler is mounted inside the unit to prevent injuries. • Small, compact, attractive Makes for an easy, eye appealing installation, as close as 18" away from a building. Installation System • 1 it (305 mm) Flexible fuel line connector Absorbs any generator vibration when connected to rigid pipe. • Direct -to -dirt composite mounting pad Complex lattice design prevents settling or sinking of the generator system. • Integral sediment trap Prevents particles and moisture from entering the fuel regulator and engine, prolonging engine life. 16/20/22 kW Generator Model Continuous GENERAC` specifications G00703541, G007036-0, G00703M, G007039.0 G007042-1, G0070434 G007037-0 (16 kW) (20 kW) (22 kM GENERAC` 16/20/22 kW switch options Limited Circuits Switch Features • 16 space, 24 circuit, breakers not included. • Electrically operated, mechanically -held contacts for fast, positive connections • Rated for all classes of load. 100% equipment rated, both inductive and resistive. • 2-pole, 250 VAC contactors. • 30 millisecond transfer time. • Dual coil design. • Rated for both copper and aluminum conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA/UL 311 aluminum outdoor enclosure allows for indoor or outdoor mounting flexibility. • Multi listed for use with 1° standard, tandem, GFCI and AFCI breakers from Siemens, Murray, Eaton and Square D for the most flexible and cost effec- tive install. Dimensions Height WUIh H7 H2 w1 � Depth in 26.75 30.1 10.5 13.5 6.91 mm 679.4 764.3 266.7 1 343.0 175.4 Wife Ranges Conductor Lug Neutral Lug Ground Lug 1/0-#14 210-#14 2A-#14 Service Rated Smart Switch Features • Includes Digital Power Management Technology standard (DPM). • Intelligently manages up to four air conditioner loads with no additional hardware. • Up to four more large (240 VAC) loads can be managed when used in conjunction with Smart Management Modules (SMMs). • Electrically operated, mechanically -held contacts for fast, clean connections. • Rated for all classes of load, log% equipment rated, both inductive and resis- tive. • 2-pole, 250 VAC contactors. • Service equipment rated, dual coil design. • Rated for both aluminum and copper conductors. • Main contacts are silver plated or silver alloy to resist welding and sticking. • NEMA7UL 3R aluminum outdoor enclosure allows for indoor or outdoor mount- ing flexibility. Dimensions 200 Amps 120/240, to Open Transition Service Rated Height Width H7 H2 w1 VV2 OePih in 26.75 30.1 10.5 13.5 1 91 mm 679A 764.3 266.7 343.0 1 175.4 Model 6007035-0 (151N) 14rcifPales 2 e s Current Rating (Amps) 100 goiW eq RalinH 4�AG};g..:: �v.,:. `:.7201240.10 Utility Voltage Monitor (Fixed* -Ack-op 80% -Oropoul 65% metumto Utility' 'ap i511 Exercises bl-weekly for 5 minutes't Standard Total Circuits Available 24 l andan Breakei ra�hiri5u m.-. 8tdndem4-1 Circuit Breaker Protected Available RMS Symmetrical 10,0o0 Fault current @ 250 volts *Function of Evolution Contrmller Exercise can be set to weekly or monthly lJ Model G007037-0 (16 kW)/6007039-0 (20 kill G007043-0 (22 kNI I o:efPoles 2 Current Rating (Amps) 200 �ge� A6}�s- r > *�720l24019''+*�'*•:' OlilityVoltage Monitor (rued* -Ack�p Bo% -nronoul 65% Lug Range 250 'Function of Evolution Controller Exercise can be set to weekly or monthly 16/20/22 kW GENERAC available accessories Model# ProductDescription' The Wi-Fl enabled LP fuel level monitor provides constant monitoring of the connected LP fuel tank. Mon G007005-0 Wi-Fi LP Fuel Level Monitor boring the LP tank's fuel level is an important step in making sure your generator is ready to run during an unexpected power failure. Status alerts are available through a free _application to notify when your LP tank is in need of a refill. Generac's Mobile Link allows you to check the status of your generator from anywhere that you have ac G0064634 Mobile Link- cess to an Internet connection from a PC or with any smart device. You will even be notified via e-mail or text message when a change In the generator% status occurs. Available In the U.S, only. G005819-0 26R Wet Cell Battery Every standby generator requires a batteryto staltthe system. Generac offers the recommended 26R wet cell battery for use with all air-cooled standby product (excluding PowerPact@). G007101-0 Battery Pad Wamler The pad wanner rests underthe battery. Recommendedfor use 4thetemperature reguladyfalls below 0°F. (Not necessary for use with AGM -style batteries). G007102-0 Oil Warmer Oil warmer slips directly over the oil fitter. Recommended for used the temperature regularly falls below 0°F. G005621-0 Auxiliary Transfer Switch The auxiliary transfer switch contact kit allows the transfer switch to lock out a single large elecbical load Contact Kit you may not need. Not compatible with 50 amp pre -wired switches. Fascia Base Wrap KO The fascia base wrap snaps together around the bottom of the new air cooled generators. This offers a G007027-0-Bisque (Standard on 22 Wo sleek, contoured appearance as well as offering protection from rodents and Insects by covering the Offing holes located In the base. K the generator enclosure is scratched or damaged, it is important to touch-up the paint to protect from GO 0570M - Bisque Paint Kit future corrosion. The paint kit includes the necessary paint to property maintain or touch-up a generator enclosure. 6006485-0 Scheduled Maintenance Kit Generac's scheduled maintenance kits provide all the hardware necessary to perform complete routine maintenance on a Generac automatic standby generator. G006873-0 Smart Management Modules are used in conjunction with the Automatic Transfer Switch to increase its Smart Management Module (50 Amps) power management capabilities. it provides additional power management flexibility not found in any other power management system. dimensions & PCs Oimensions shmm are appmAmale, Refer IU inaalion manual far eecl dimensiow. DO NOT USE THESE DUENSIONS FOR wSTALIATION PURPOSES. GENERAC® Model UPC G007035-0 696471070354 G007036-0 696471070361 6007037-0 696471070378 G007038-0 696471070305 G007039-0 696471070392 G007042-0 596471070422 G007043-0 696471070439 Generac Power Systems, Inc. • S45 W29290 HWY. 59, Waukesha, WI 53189 • generac.com &2017 Generac Power systems, ho.9 dou resereed.A0 specrWons are sublesdto ehan0e-mums nol'me.Pml No. 10000000194E M 17