HomeMy WebLinkAboutROOF FRAMING PLANSCANNED
BY
®= � PSI APPROVAL 2017-11-14 ly
ROOF SHEATHING OPTIONS: -
- BOX RIB ALUMINUM
„ - 29 GAUGE STEEL AG PANEL DESIGN PRESSURES
-STANDING SEAM STEEL ROOF +27.8/-94.7
ASPHALT SHIGLES WALLS/DOORS/WINDOWS +32.5/-29.2 co iun wax _
BO'-D" MAXIMUM BUILDING LENGTH - 30'-0" MAX FOR VAULTED ROOF
� �n v nuxs
onmw
xION.I n6LIR mNC6N
f,p9 04Y ,un
,Mn4K LVx01f[iWRifi.C[�
MVG,[X,1[n .I
wwL LmKL
RMS�ONS r1' �
R OES[RNiON WE Bf
I
in
O
r
0
ao
w METAL FRAMI I v/n/n
® 24" O.C. x/r.
s PE
naPL �_s_�
END WA TRUSS END WA TRUSS
:A:
I x "w"m4o
m....�en....~
I —OPTIONAL PORCH-4- OR 6'� RAFTERS ARE IN -LINE WITH WALL STUDS g ♦\\\EW T..,Bq 2j�i s
ROOF FRAMING PLAN FOR CONTINUOUS LOAD TRANSFER PATH J ♦♦♦�/� vc Nsc
i .P i\ STATEOF �(V
FLOR IOPt\.Z�`�
O ii��Sylo .......�G♦♦♦
//IINAIII\\♦\♦
w "'M*T. BOWin PL
O CkeMe L:cm.e 6. EOB
� ��•� FBPR-1 OF 7
veu¢o
SLOPL
I
I
I
unno
SLOPC
I�
I w
I r
sxowo
sLORL
STA
iJ
I
ARD!RIDG
fAG6REWEW
3.5 -20GA METAL COLLAR TIE, 4'-0-
LONG ATTACHED WITH (2) #10 SELF
DRILLING GRABBAR SCREWS EACH SIDE
3
SEE ROOF
SCHEDULE FOR RAI
PSI APPROVAL 2017-11-14
2.5'X.5' CORRUGATED ROOF PANELS
FASTENED WRH .25'-1405' HWH
TRAXX/I AT 6' D.C.
3.5-20GA METAL STUDS
SPACED AT 24' D.0 MAX.
ATTACH ROOF FRAMING TO
TOP PLATE OF WALL FRAMING
WITH BUILDEX 10-16X1 TEKS
PANHEAD SCREWS WITH B3 DRILL
POINT AT 6' D.C.
OVERHANG OPTION DETAIL
3.5'-20GA METAL STUDS,
SPACED AT 24' O.0 MAX.
_ SELF BRACE AT
ABOVE FINISHED FLOOR. T/I]/1T
ATTACH TO EACH STUD W/(2) #10
SELF DRILLING GRABBER SCREWS, N/A
FL
(I) INTO EACH FLANGE W_6_L;
SHEATHING FASTENED W/
A8n1.5' GRABBER SCREW (OR ATTACH ROOF FRAMING TO
EQUAL) AT 6' O.C. 70P PLATE OF WALL FRAMING
WITH BUILDEX 10-I6X1 TICKS
PASCREWS WRH /3 DRILL
POINTOINT AT 6' O.C.
—VARIES, 6'-0' TO 13'-B'
SEE ROOF
FRAME SECTION SCHEDULE FOR RAI
BRACING
3.5-20GA METAL STUDS
SPACED AT 24' D.0 MAX.
OVERHANG OPTION DETAIL
W
O
CO
CC
(n
\\�EW T.F8"!'*
\�L��i
L+T
`\FY �j�J�10ENyF
I
TIT
}O i STATEOF
Q�il�.n��,
/It,
��AI toNA
0
fit 11,"\\\
La-
Koun.. t SW " P.[
0
6M.I. FBPR-2 OF 7
=
-=-
PSI APPROVAL 2017-11-14
fA��EW
Ohs-M�eWum�ev
on �imrm nen�
TT
WALL SHEATHING OPTIONS:
— BOX RIB ALUMINUM
— TWIN RIB ALUMINUM
DUTCH LAPSIDING ALUMINUM
SECURED WITH — DUTCH LAPSIDING STEEL SIDING
(2)H3 OR EQUAL — 29 GAUGE STEEL AG PANEL (RUN ANY DIRECTION)
— J" T-111 WOOD SIDING
DOUBLE 3.5" 20GA. — HARDIE PANEL STUCCO AND T-111 SIDING
STEEL TOP PLATE — HARDIE BOARD SIDING
END WALL POLYCARBONATE GREENHOUSE PANELS
4x4 P.T. POST
3.5"
ZGA. STEE
BRACE
(2)
#10 SEII
TAPPINC
SCREWS
E ACH
/ /
/ /
E
(1 INT
EACH FI
IGE)
i+l
(2)MITEK OR ALPINE
.5" 20C
STEEL
3"x5" OR EQUAL
STU
024"
MAX.
—4'&6' OPTIONAL PORCH—
50'-0" MAX.
STANDARD WALL DETAIL
3.5" 20GA. STEEL
/TOP PLATE
END WALL
3.5" 20GA. STEEL
SOLE PLATE
FLOOR FRAMING
18-5-�eE
mR
W
acwa
0
0 .e
OEAR
K
O
a
_
It 11V • fa,"'
F
0
Oa
'ii
i�`1 STATEOF �(V:
FLORIOP
Q
NAL
W
Ror�eo u`enb &zm
N
�.1. FBPR-3 OF 7
_fiffl&__
COOER EW
n.o-wwa� .Hawn
ve/Mf w�l
�� lixx w)qe qir
v m4x gry�r-v'
) 0 P.lLgWmY1 YR6
11Mp r4n Iwx[
PSI APPROVAL 2017-11-14
mw wau nscvo
END WALL FRAMING OPTION
/t Y g (j Mo)Wx Nwa[ [vx rmo ./It�llo
"sivlM'.uq wpu. rm.x
mrr .... R «M� exser ul Ma va ruin)
rou m4 evrcxr e n r-p'
)urN wo ra sw) v w �m nooa
[ rq ul .eo 4c.1uw[ /ul I
essv°mulwl
END WALL FRAMING OPTION
END WALL FRAMING OPTION
� NR.t BI1/[ari.
6 111 MO)4[N NIWQ
we
tS-S-FFE
YIIII
w
YAI,tDIq
O
m
lv.:¢
uoeem
N
�glgr�4 u r
g
fillll
\�A0%11% T: B l�
rn
LQ 4
0
��`\ STATE OF Jf(y�
i0. '-, F�ORIDP f24r\\�
'llll
I10NA� �M\`%`\\\\
3
Wll�e. 1. Bop.n P.F.
Q
flwieo 4[.n,e H6C8
FBPR-4 OF 7
N
roOEREvIEw� m..
'VALUES ARE FROM END Of J06i
TO CENTERS OF SKIDS ONLY.
PSI APPROVAL 2017-11-14
-NOTE: JOISTS CAN BE EITHER S2 S.Y.P. OR 18 GAGE
STEEL CHANNELS. THE STEEL CHANNEL ACTUAL
DIMENSIONS MATCH THE WOOD ACTUAL DIMENSIONS AND
ARE INTERCHANGEABLE,„M
-FLOOR SHEATHING SECURED WITH *XO. 113'
NAIL (OR EQUAL) 0 6-O.C. MAX
50'-0" MAX.
16 O.C. TYP.
CO E INf PVAIpN
CIX H Y
Riga
w m
ouw�m
ornszmlz
alowar. wwo
`°rm
w aT Iwo
"0q1 p°°10'0
ax w'o
Q
sN Na rmw9
r
R NSOIN
R OESCRWNN
MlC Hr
7/12/IT
N/A
W-S-L"
W
Wi'umo"�e
OED
N
ri °O+iue
nou
a.
...P"meao vax
5
N
F-
O
Y
Tau,,,/'
(ow"Oft
i "P STATE OF //j
iG.n AEORION
// Fri..., 'G�
/''/ONAj1T`����`
P.T SIDE RAIL TO MATCH
JOISSCHEDULEE FOR SIZES ING
P.T 4x6 S,Y.P Q2 OR (2) P.T. 2x6
S.Y.P. #2 SKIDS
2 SKID FLOOR FRAMING PLAN
OPTIONAL PORCH
°o
uallne. 1. PoW.w P.E.
FBPR-5 OF 7
SKID RUNNER SPACING*
UNDER 30' LENGTH
SHED WIDTH
A
B
6'_p•
15'
4Y
8'-0"
1B'
6D'
10'-0"
IB'
B4"
11'_p^
29
84
11'-8"
28'
e4'
13'-0"
36'
B4'
6'-1" TO 11'-8"
>
�'� PSI
APPROVAL 2017-11-14
II X' "NOTCH
m E MDR.NIWN
mx nes.x
"�_Ca e
FOR EACH JOIST
mmm�a rvn
ATTACK JOIST TO SKID WITH (`k"x4"
LAG SCREW OR (2)SIMPSON H-3
60P"
(OR EOUAL) AT EACH CROSSING
12" LAP SPLICE FASTENED WITH (6)&"x4"
wuo..1
LAG SCREWS ON INSIDE. (3 LAG
k4" L)
'j SCREWS ON OUTSIDE (9 TOTAL)
JOIST TO SKID
m um
CONNECTION
4"x6" P.T. SKID SPLICE
F
XKRIPTON -ERE
WALL SHEATHING
3.5" 2013A STEEL STUDS 029'b.C.
' Nf9
I/1]/1]
N/.
3.5" 20GA. STEEL-s-Iaz
P7 ........e....
12
SOLE PLATE SECURED
WITH T�"x4" LAG FLOOR SHEATHING
•.�."�."",,. +�nca. ro.. m�
S
SCREWS 016"LAG
FLOOR JOIST
Q
�I, �,x•�n
,��.,.�,,..,.:.n..m....n,,.
1.5
m
•
�. ' SENCO K28 (OR EQUAL) NAILS, TWO
r ---------------------
I
:.an....nR�o,.k�rv.�:"
..,. n.,..n M�..
.e.o-.e.omn...m
j ROWS 1.5" FROM THE EDGE, ® 12"
L
W
rm
.m.,...n..�,...n,.
` •' O.C., STAGGER ROWS 6".
-----------------------
3'x6' SPLICE PLATE FASTENED WRH
(5)—SENCO K28
2"x4" BLOCKING BETWEEN SKIDS 2K BLOCKING BETWEEN SKIDS AT
R
(OR EQUAL) NAILS
EACH SIDE
UNDER DOUBLE END JOIST BOTH ENDS SECURED TO END JOIST
g
\\\\T1W T
E B /
SECURED WITH (3) WITH 3 0.120".3" NAILS 012"O.C.
EACH SIDE STAGGERED
\\ ....E.....
NAILS 012"O.C. STAGGERED
STAGGERED
W
(2) 2"x6" P.T. SKID
WALL TO FLOOR
�`P"Y
�� k
SPLICE/SECURING
CONNECTION DETAIL
=p STATEOF
Q
/A,
i@ ALORIOP
INAf\
pueNm.
I. Rep.im P.[,
sK.1. FBPR-6 OF 7
M,—
�o
F_I F�jURICAL
SYMBOL KEY
ll
1i
I1
RECEPTACLE
240V
240
RECEPTACLE
SINGLE POLE
SWITCH
THREE WAY
SWITCH
CEILING MOUNT
�J
LIGHT FIXTURE
i�
WALL MOUNT
v
LIGHT FIXTURE
FLUORESCENT
LIGHT FIXTURE
JUNCTION BOX
1. ALL WIRE TO BE #12 THHN SOLID COPPER WITH GROUND. WIRING PROTECTED BY NEC 2014 EDITION.
2.Fl%TURF LOCATION AND TYPE MAY VARY
3-PLASTIC OR METAL 'NEW WORK' OUTLET BOXES
4.20A GFCI OUTLETS
5. ALL RECEPTACLES TO BE AT 12 -16' A.F.G.: MAXIMUM B RECEPTACLES.
6. ALL SWRCHES TO BE AT 48'-52' A.F.G.
7. FLUORESCENT k LED LIGHTS MAY SUBSTITUTE FOR INCANDESCENT LIGHTING
B, ALL OUTLETS TO BE GFCI
9. THE MAIN ELECTRICAL PANEL, FEEDERS, POWER HOOKUP TO UNIT (INCLUDING ALL DISCONNECTS, OVER CURRENT
DEWCES. PANELS, GROUNDING, ETC.) IS DESIGNED BY OTHERS. SITE INSTALLED. AND SUBJECT TO LOCAL APPROVAL.
0
0
m
WINDOW HEIGHT, LOCATION
AND OUANBIT MAY VARY
AND ARE OPTIONAL
SEE VARIOUS END WALL
FRAMING SECTIONS FOR
WALL AND DOOR FRAMING
3.5' METAL STUDS
SPACED AT 24'
U.C. MAX
SEE VARIOUS END WALL
\T/{. FRAMING SECTIONS FOR
WALL AND DOOR FRAMING w
x
0
\ I m
/ w
0
IN
a
g
J
J w
w
F-
N
WP I
OPTIONAL ELECTRIC TO EACH UNIT N
WILL BE FIELD CONNECTED FROM
EXISTING POWER SOURCE
W
Q
0'-0' MAXIMUM BUILDING LENGT Q
_U
NOTE: ALL ELECTRICAi EQUIPMENT SHOWN IS OPTIONAL AND LOCATIONS MAY VARY a:
U
w
y J
w
N
Na T . 4
�10ENgF
STATE OF
Al 0RIUP
FBPR-7 OF 7
i