HomeMy WebLinkAboutPRODUCT APPROVALr ('aw-4
Business ®_
M-0
:ProfessionalRegulation
K
BQs Home I Log In i user Regatratlon I Hot Topics submit sumhame st2n a F.= I PubllWtuns I Contatt Us I BQs site Map Unks I seamh i
dba -�y1,-{'
r V-1piUSER:ProdPubliccUaa, Approval SCANNED
yp iii���''' RECEIVED BY
po,,i Approval Menu > Product or Application Seamh > Aoolitation List > Application Detail St. Lucie County
FL # FL27076 APR 2 2 2019
Application Type New
Code Version 2017 ST. Lucie County, Permittinq
Application Status Approved
*Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by
TT the POC and/or the Commission If necessary.
Com-24
Archived VA111i❑
die
ddu�ufacturer
s mail
Au[hortiCzetl.6d p�ur
Technical Rep a[it,
A�d�e �+r�
Address/Phone/Email
Quality Assurance Representative
Address/Phone/Email
Category
Subcategory
Compliance Method
Certification Agency
Validated By
i
Referenced Standard and Year (of Standard)
Equivalence of Product Standards
Certified By
Product Approval Method
Date Submitted
Date Validated
Date Pending FBC Approval
Date Approved
APOC, Sub of Gardner -Gibson, Inc.
4161 E. 7th Avenue
Tampa, FL 33605
(813) 248-2101 Ext 1141
mmullins@gardner-gibson.com
Matthew Mullins
mmullins@gardner-gibson.com
Roofing
Underlayments
Certification Mark or Listing
Miami -Dade BCCO - CER
Miami -Dade BCCO - VAL
Standard
ASTM D1970
ASTM D226
TAS 103
Approved Testing Lab
FL27076 RO Eaviv FL23128 Equivalency Letter odf
Method 1 Option A
04/27/2018
06/04/2018
06/11/2018
Year
2015
2009
1995
Summary of Products
I
FL #
Model, Number or Name
Description
27076.1
APOC 25
Asphalt Saturated Felt underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructions
Other:
FL27076 RO TI 18040906.odf
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
27076.2
APOC 45
Asphalt Saturated Felt underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructions
Other:
FL27076 RO IT 18040906.odf
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
12707(73)
FAPOC.7uff=FeTt_26)
Asphalt Saturated Felt underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructions
Other:
FL27076 RO II 18040906.odf
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
27076.4
APOC Tuff -Felt 46
Asphalt Saturated Felt underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructlons
Other:
FL27076 RO II 18040906.odf
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
27076.5
Gard -Lock
Glass fiber reinforced, polymer modified asphalt, granulated
self -adhered underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructions
Other:
FL27076 RO II 1804090k gi f
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
27076.6
GatorSkin
Synthetic roof underlayment
Limits of Use
Certification Agency Certificate
Approved for use in HVHZ: Yes
FL27076 RO C CAC 18040906.odf
Approved for use outside HVHZ: Yes
Quality Assurance Contract Expiration Date
Impact Resistant: N/A
03/28/2023
Design Pressure: N/A
Installation Instructions
Other:
FL27076 RO II 18040906.2df
Verified By: Miami -Dade BCCO - CER
Created by Independent Third Party:
Evaluation Reports
Created by Independent Third Party:
27076.7
1GatorSkin-10
Synthetic roof underlayment.
Business & Professional Regulation—
irJll
acts Home I Log In I User Registration I Hot Topi¢ I Submit surcharge I Stars&Fact Publications I contact Us I BUS Site Map Links I Search
a
dbpr �IUProduct App
SER: Public
SCANNED
L BY
Pmdud Aoomval Menu > Produd or Avogcation Seamb > AOPgcation List > Application Derail St. Lucie County
FL # FL17022-R7
Application Type Revision
Code Version 2017
Application Status Approved
Comments
08/18/2017v. date reapply 08/21/17
Archived
❑
Product Manufacturer
Extreme Metal Fabricators,
LLC RECEIVED
Address/Phone/Email
2160 SW Ponta Drive
Palm City, FL 34990
(772)872-8034
APR 2 2 M9
fivalidation@yahoo.com
ST. Wrig County, Permitting
Authorized Signature
Richard MCKuhen
-
flvalidation@yahoo.com
Technical Representative
Richard MCKuhen
Address/Phone/Email
2160 SW Poma Drive
Palm City, FL 34990
(772) 872-8034
rchard@emfab.net
Quality Assurance Representative
Address/Phone/Email
Category Roofing
Subcategory Metal Roofing
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida
Professional Engineer
❑ Evaluation Report - Hardcopy, Received
Florida Engineer or Architect Name who developed LOCKE BOWDEN
the Evaluation Report
Florida License PE-49704
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 04/22/2024
Validated By Zachary R. Priest, P.E.
0 Validation Checklist - Hardcopy Received
Certificate of Independence FL17022 R7 COI FL 17022.1 5 V CRIMP ssr.pdf
Referenced Standard and Year (of Standard) Standard
TAS 125
UL 1897
UL 580
Equivalence of Product Standards
Certified By
Sections from the Code
Year
2003
2012
2006
Product Approval Method Method 1 Option D
Date Submitted 08/18/2017
Date Validated 08/25/2017
Date Pending FBC Approval 08/28/2017
Date Approved 10/10/2017
Summary of Products
FIL 7r
Model, Number or Name
Description
17622:.11
-f-jV,Cr
26 Gauge steel, 3/8" rib height, 24" wide lapped roof panel
mechanically attached to 15/32" plywood or Wood Deck with
fasteners
Limits o} Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 11 FL 17022.1 5 V CRIMP ssr odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17022.1 5 V CRIMP ssr.odf
assembly in compliance with the installation method listed in
Created by Independent Third Party: Yes
this report and applicable code sections of FBC. Refer to
manufacturer's installation Instructions.
17022.2
2 - "5V Crimp" (116)
0.032" Aluminum, 3/8" Rib height, 21" wide lapped roof
panel, mechanically attached to 15/32" plywood or Wood
Deck with exposed fasteners
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 II FL 17022,2 5 V CRIMP 0,032 ALUM ssr ndF
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions. Install the
FL17022 R7 AE FL 17072,2 5 V CRIMP 0.032 ALUM ssr odf
Created by Independent Third Party: Yes
assembly in compliance with the installation method listed in
this report and applicable code sections of FBC. Refer to
manufacturer's installation instructions.
17022.3
3 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 24 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 it FL 17022.3 1,5 MECHANICAL
Approved for use outside HVHZ: Yes
seam 24aa ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17027 R7 AE FL 17022.3 1.5 MECHANICAL
installation method listed In this report and applicable code
sections of FBC. Refer to manufacturer's Installation
seam 24aa ssr.odf
Created by Independent Third Party: Yes
instructions.
17022.4
4 - "1.5" Mechanical Seam" (R5)
1.5" rib height, 16" wide, 0.032" aluminum, standing seam
roof panel mechanically attached to 15/32" plywood or Wood
Deck with clips and fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 11 FL 17022.4 MECHANCIAL SEAM
Approved for use outside HVHZ: Yes
ALUMINUM ssr.odf
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Party: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.4 MECHANCIAL SEAM
installation method listed in this report and applicable code
ALUMINUM ssr.odf
sections of FBC. Refer to manufacturer's installation
Created by Independent Third Party: Yes
Instructions.
17022.5
5 - "1 in. Nail Strip" (115)
1" rib height, 16" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 IT FL 17022.51
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.5 1.0 NAILSTRIP ssr.odf
Created by Independent Third Party: Yes
limitations of use. Install the assembly in compliance with the
installation method listed In this report and applicable code
sections of FBC. Refer to manufacturer's installation
Instructions.
17022.6
6 - "1 in. Nail Strip" (RS)
1" rib height, 16" wide, 0.032" aluminum, standing seam roof
panel mechanically attached to attached to 15/32" plywood or
Wood Deck with fasteners,
Limits of Use
Installation Instructions
Approved for use in HVHZ: No
71-17022 R7 II FL 17022 6 1.0 NAIL STRIP 0,032
ALUM ssr.odf
Approved for use outside HVHZ: Yes
Impact Resistant: No
Verified By: Locke Bowden, P.E. 49704
Design Pressure: +N/A/ -Table A
Created by Independent Third Parry: Yes
Other: Refer to evaluation report for conditions and
Evaluation Reports
limitations of use. Install the assembly in compliance with the
FL17022 R7 AE FL 17022.6 1.0 NAIL STRIP 0,032
ALUM ssr.odf
installation method listed In this report and applicable code
sections of FBC. Refer to manufacturer's Installation
Created by Independent Third Parry: Yes
Instructions.
17022.7
7 - "1.5 in. Nail Strip" (RS)
1.5" rib height, 19" wide, 26 gauge steel, standing seam roof
panel mechanically attached to 15/32" plywood or wood deck
with fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 II FL 17022.7 1.5 Nall Strip 26GA ssr odf
Verified By: Locke Bowden, P.E. 49704
Approved for use outside HVHZ: Yes
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.7 1.5 Nall Strip 26GA ssr ndf
Created by Independent Third Party: Yes
limitations of use. Install the assembly In compliance with the
installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
instructions.
17022.8
8 - "EMAX Rib" (115)
29 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 IT FL 177022.8 EMAX Rib ssr odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 177022.8 EMAX Rib ssr odf
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's installation
Instructions.
17022.9
9 - " PER MAX" (RS)
26 gauge steel, lapped roof panel mechanically attached to
15/32" plywood or wood deck with exposed fasteners.
Limits of Use
Installation Instructions
Approved for use In HVHZ: No
FL17022 R7 II FL 17022.9 PBR RIB ssr odf
Approved for use outside HVHZ: Yes
Verified By: Locke Bowden, P.E. 49704
Impact Resistant: No
Created by Independent Third Party: Yes
Design Pressure: +N/A/ -Table A
Evaluation Reports
Other: Refer to evaluation report for conditions and
FL17022 R7 AE FL 17022.9 PBR RIB ssr.odf
limitations of use. Install the assembly in compliance with the
Created by Independent Third Party: Yes
Installation method listed in this report and applicable code
sections of FBC. Refer to manufacturer's Installation
Instructions.
Beck Nea[
Contact Its :: 2601 Blair Stone Real. Tallahassee K 32399 Phone: 850-487,1824
The state of Florida Is an AA/EW employer. Ccovdcht 2007.2013 State of funds.:: Pnvaw Statement :: Awasslbilly Statement :: Refund Statement
Under Florida law, email addresses are public records. If you do not want your e-mall address released in response to a public -records request, do not send electronic
mall to this entity. Instead, contact the office by phone or by traditional mall. If you have any questions, please contact 850.487.1395.'Pumuant to section 455.275(1),
Florida statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. must provide the Department with an small address If they have one. The smalls
provided may be used for official communication with the licensee. However email addresses are public record. If you do not wish to supply a personal address, please
previtle the Department with an email address which can be made available to the public. To determine if you are a licensee under Chapter 455, F.S., please ani<here
Product Approval Accept:
"M go
Credit Card
Safe
Palm City, FL 34990
Compliant with Florida Building Code 2017 (6th ed.)
Compliant with Florida Product Approval Rule # 61G20-3
Compliant: Keystone Certifications
Product: 5 V Crimp 26GA Steel Roof Panel FBC Sec. 1507.4.2
Yield strength: 50 ksi min.; Attached to min.15/32" plywood or Wood
Deck w/ min. 0.42 specific gravity with screws. 24" Coverage
Rib Height 3/8"
Corrosion Resistant Compliant: FBC Sec.1507.4.3
Fastener 1(Method 1 Attachment): #9 x 1-1/2" Hex -Washer Head wood screw* to penetrate
3/16" min. thru deck or 5/8" embedment into wood plank. (*or sufficient length to meet
requirements)
Fastener 2 (Method 2,3, & 4 Attachment): #10 x 1-1/2" Hex -Washer Head wood screw* to
penetrate 3/16rr min. thru deck or 5/8" embedment into wood plank. (*or sufficient length
to meet requirements)
Underlayment: To be compliant with FBC Sec. Chart 1507.1.1
Slope: Shall be in compliance with FBC Sec. 1507.
See Fastener attachment specifications above
Install Details: Table A Allowable Loads
METHOD 1
METHOD 2
METHOD 3
METHOD 4
DESIGN PRESSURE*
-86 PSF _
-93.5 PSF
-101 PSF_
-228 PSF
ROW SPACING
16" o.c.
16" o.c.
8" O.C.
6"o.c.
FASTENER SPACING (ALONG -Panel width)
12" O.C.
12" ox.
12" O.C.
12" o.c.
FASTENER SIZE
#9
#10
#10
#10
Reference Data: ARCHITECTURAL TESTING, INC. TST ID#: 1527
UL 580-06 & 1897-041 Test Report EMS93.01-450-18 05/02/14
Test Report F3366.01-450-18 12/18/15
TAS 125-03 Test Report D05893.02-450-18 07/22/14
*EQUIVALENCY-UL 1897-04 is equivalent to test standard UL 1897-1 *Design pressure margin of safety 2:1
.rr nnr...-
Locke Bowden, P.E. does not have, not will acquire a financial
under this evaluation.
Locke Bowden, P.E. is not owned, operated, or controlled by i
report.
compar0pm4fiafakture►,
cerzip�•.�t
•�: �rONAL �'..;�'
distributing products
products under this
/%
FL17022.1 5V Cri,. , ' (26GA Steel), 24" Wide Roof Pa, - Details
Limitations:
1. Underlayment to be compliance with current Florida Building Code (FBC)2017 6t' ed.
2. Minimum slope to be compliant with Florida Building Code 2017 6th ed., and per with Manufacturer's installation reference.
3. Products are compliant for State of Florida product approval per Rule 61 G20-3. Compliance Method: 1-D
4. Engineering analysis for "project specific approval by local authorities w/jurisdiction is allowed by other registered engineers.
5. Fire classification is not part of this acceptance. Shear diaphragm values are outside this report.
6. Support framing in compliance w/FBC 2017 6r' ed., Chapter 22 for Steel, Chapter 23 for Wood and Chapter 16 for
Structural Loading.
7. This report does not imply warranty, installation, recommended product use outside of this report.
Fasteners -
#9.1-112"Min. or
#10 x 1-1/2• Min. per Table A' for Row 5-V Cnmp Roof Panel
Spacing and Design Pressures
HexWasherHead Wood Screws
g U
s
r
Deck-,
-15132" or greater Plywood, or
- Wood plank
24-
12
31W
T-- - -- -
Nominal 12"
O.G.
Panel Profile
Nominal 1
O.C.
Fasten
g x -1/2" Min. or #10 x 1-1/2" Min. per
Table "A" Hex Masher Head Screw
Spaced 12" o.c. across the Panel Width
Panel Refer to Table "A" for Spacing Along Panel
Overlap Length
Deck-15/32" or greater
Plywood, or
-Mod plank