Loading...
HomeMy WebLinkAboutREVISION BUILDING PERMITOFFICE USE ONLY: DATE FILED: 4&hy REVISION FEE: 00 LOCATION/SITE ADDRESS: FILE COPY PERMIT # S 04-us� RECEIPT # PLANNING & DEVELOPMENT SERVICES BUILDING & CODE REGULATION DIVISION SCANNED 2300 VIRGINIA AVENUE BY FORT PIERCE, FL 34982.5652 (772) 462.1553 St. Lucie County APPLICATION FOR BUILDING PERMIT REVISIONS PROJECT INFORMATION DETAILED DESCRIPTION OF PROJECT CONTRACTOR INFORMATION: STATE of FL REG./CERT. #: BUSINESS NAME: Aull QUALIFIERS NAME: ADDRESS: 21 1 SI: CITY: (- PHONE DAYTIME):� OWNER/BUILDER INFORMATION: NAME: 'K, ADDRESS:_ CITY: " PHONE(DA STATE: ARCHITECT/ENGINEER INFORMATION: IMMI ST. LUCIE CO CERT. #: FAX: FAX: ZIP: ZIP: DI' CITY: STATE: ZIP: PHONE (DAYTIME): FAX: Revised 06130117 ®I IE 1 Professional Regulation BaSHome I Login I User Registratlon I Hat Tapl¢ I submit Sumharge I SMM&Fam I Publications I Caotatt Us I BraSSite Map I Links Search bpre Product SCAN NED O USER: BY au St. Lucie Du Pmautt Poorvval Menu >PmEutt or Application SearcM1>Aoollatlon Lis[>AppllwUon Detail I� jgbq — 0� •. FL# _..._ FL23089-R2 REVIEWED FO / Application Type Revision Code VersionCODE C®MPLI CE 2017 COUNTY Application Status Applied For ST. LUCIE COUNTY Comments BOCC Archived ❑ Product Manufacturer Sun-Tek Mfg Address/Phone/Email 10303 General Dr Orlando, FL 32824 (407)859-2117 jfeudner@sun-tek.com Authorized Signature James Feudner engineering@sun-tek.com Technical Representative James Feudner Address/Phone/Email 10303 General Dr Orlando, FL 32824 engineering@sun-tek.com Quality Assurance Representative James Feudner Address/Phone/Email 10303 General Dr Orlando, FL 32824 (407) 859-2117 Ezt 111 engineering@sun-tek.coni Category Sky Lights Subcategory Skylight Compliance Method Certification Mark or Listing Certification Agency Miami -Dade BCCO - CER Validated By Miami -Dade BCCO - VAL Referenced Standard and Year (of Standard) Standard Year TAS 201 1994 TAS 202 1994 TAS 203 1994 Equivalence of Product Standards Certified By Product Approval Method Date Submitted Date Validated Method 1 Option A 11/26/2018 Summary of Products FL # Model, Number or Name Description 23089.1 fMAsv CMA-D Aluminum Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL23089 R2 C CAC CMA-D17102320 odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 02/22/2021 Design Pressure: +60/-60 Installation Instructions Other: FL23089 R2 11 CMA-D17102320 odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: - Evaluation Reports Created by Independent Third Party: 23089.2 HSF Hurricane Self Flashing (HSF) Aluminum Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL23089 R2 C CAC HSF17102319 odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 01/10/2021 Design Pressure: +60/-60 Installation Instructions Other: FL23089 R2 IT HSF17102319 odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 23089.3 ICMG ICMG skylight system Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes FL23089 R2 C CAC ICMG18071604 odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10/10/2023 Design Pressure: +80/-80 Installation Instructions Other: FL23089 R2 II ICMG38071604 odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 23089.4 ISFG ISFG skylight system Limits of Use Certification Agency Certificate Approved for use In HVHZ: Yes FL23089 R2 C CAC ISFG38071603 df Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes 10131/2023 Design Pressure: +80/-80 Installation Instructions Other: FL23089 R2 II ISFG18071603.odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 23089.5 MD-CMA MD-CMA Skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes F1 23089 R2 C CAC MDCMA17102318 odf Quality Assurance Contract Expiration Date Impact Resistant: Yes 03/13/2023 Design Pressure: +60/-60 Installation Instructions Other: FL23089 R2 II MDCMA17102318 df Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: 23089.6 Sun-Tek Tubular skylight curb mounted tube skylight Limits of Use Certification Agency Certificate Approved for use in HVHZ: Yes F123089 R2 C CAC Tub 18041802 odf Approved for use outside HVHZ: Yes Quality Assurance Contract Expiration Date Impact Resistant: Yes Design Pressure: +65/-65 Other: 05/26/2023 Installation Instructions FL23089 R2 II Tube18041802.odf Verified By: Miami -Dade BCCO - CER Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: Contact Us :: 2601 Blair Stone Road, Tallahassee R 32 99 Phone: 850-482-1824 The State of Fladda Is an AAIEW employer, Copyright 2007-2013 State of Flodtla.:: Pdvacv Statement :: Accessibility Statement:: Refund Statement Under Florida law, email addresses are public records. if you do not want your a -Mali address Misused In response to a public -Moo ds request, do not send electronic mall to this enbry. Instead, contact the office by phone or by traditional mall. if you have any questions, please contact 850.487.1395. *Pursuant to Section 455.275(1), Florida Statutes, effective October 1, 2012, licensees licensed under Chapter 455, F.S. most provide the Department with an email address If they have one. The smalls providetl may be used for official communication with the licensee. However email addresses are public remm. If you do not wish to supply a personal address, please provide the Department with an email address which can be made available to the public To determine if you are a licensee under Chapter 455, ES., please dick here . Produce ApPmval Accepts: ® = ® EE Credit Card Safe MIAMI•DADE MIAMI-DADE COUNTY o PRODUCT CONTROL SECTION DEPARTMENT OF REGULATORY AND ECONOMIC RESOURCES (RER) 11805 SW 26 Street, Room 208 BOARD AND CODE ADMINISTRATION DIVISION Miami Florida 33175-2474 T (786) 315-2590 F (786) 315-2599 NOTICE OF ACCEPTANCE (NOA) www.miamidade.eov/economy Sun-Tek Manufacturing, Inc. 10303 General Drive Orlando, FL 32824 SCOPE: This NOA is being issued under the applicable rules and regulations governing the use of construction materials. The documentation submitted has been reviewed and accepted by Miami -Dade County RER- Product Control Section to be used in Miami Dade County and other areas where allowed by the Authority Having Jurisdiction (AHJ). This NOA shall not be valid after the expiration date stated below. The Miami -Dade County Product Control Section (In Miami Dade County) and/or the AHJ (in areas other than Miami Dade County) reserve the right to have this product or material tested for quality assurance purposes. If this product or material fails to perform in the accepted manner, the manufacturer will incur the expense of such testing and the AHJ may immediately revoke, modify, or suspend the use of such product or material within their jurisdiction. RER reserves the right to revoke this acceptance, if it is determined by Miami -Dade County Product Control Section that this product or material fails to meet the requirements of the applicable building code. This product is approved as described herein, and has been designed to comply with the High Velocity Hurricane Zone of the Florida Building Code. DESCRIPTION: Model CMA-D Aluminum Skylight APPROVAL DOCUMENT: Drawing No. CMA D-004, titled "CMA-D", sheets I and 2 of 2, dated 05i22/2000, prepared by the manufacturer, signed and sealed by James D. Wells, Jr., P.E., on 10/06i2017, bearing the Miami -Dade County Product Control revision stamp with the Notice of Acceptance number and the expiration date by the rvhami-Dade County Product Control Section. MISSILE IMPACT RATING: Large and Small Missile Impact Resistant LABELING: Each unit shall bear a permanent label with the manufacturer's name or logo, city, state, model/series and following statement: "Miami -Dade County Product Control Approved", unless otherwise noted herein. RENEWAL of this NOA shall be considered after renewal application has been filed and there has been no change in the applicable building code negatively affecting the performance of this product. TERMINATION of this NOA will occur after the expiration date or if there has been a revision or change in the materials, use, and/or manufacture of the product or process. Misuse of this NOA as an endorsement of any product, for sales, advertising or any other purposes shall automatically terminate this NOA. Failure to comply with any section of this NOA shall he cause for termination and removal of NOA. ADVERTISEMENT: The NOA number preceded by the words Miami -Dade County, Florida, and followed by the expiration date may be displayed in advertising literature. If any portion of the NOA is displayed, then it shall be done in its entirety. INSPECTION: A copy of this entire NOA shall be provided to the user by the manufacturer or its distributors and shall be available for inspection at the job site at the request of the Building Official. This NOA revises NOA #15-0513.08 and consists of this page I and evidence pages E-I & E-2, as well as approval document mentioned above. The submitted documentation was reviewed by III y A. Makar, NOA No.17-1023.20 MIAMMADECOUNTr �•✓GY -" Expiration Date: 02/22/2021 Approval Date: 02/22/2018 oZlZ2lZ�iB Page 1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 1. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 12-0517.24 A. DRAWINGS 1. Drawing No. CMA-D-004, titled "CMA-D", sheets 1 and 2 of 2, dated 05/22/2000, prepared by the manufacturer, signed and sealed by James D. Wells, Jr., P.E. B. TESTS "Submitted tinder NOA # 11-0114.03" 1. Test reports on 1) Air Infiltration Test, per FBC, TAS 202-94 2) Uniform Static Air Pressure Test, Loading per FBC TAS 202-94 3) Water Resistance Test, per FBC, TAS 202-94 4) Large Missile Impact Test per FBC, TAS 201-94 5) Cyclic Wind Pressure Loading per FBC, TAS 203-94 6) Forced Entry Test, per FBC 2411 3.2.1, TAS 202-94 along with marked -up drawings and installation diagram of CMA-D Polycarbonate Aluminum Fixed Skylights, prepared by National Certified TestingLaboratories, Test Reports No. 210- 3716-2, dated 11/22/2010, with a revision dated 03/07/2010, signed and sealed by Gerard J. Ferrara, P.E. C. CALCULATIONS "SubmRted under NOA # 11-0114.03" 1. Anchor calculations prepared by J & L Wells Consulting LLC, dated 01/04/2011, signed and sealed by James D. Wells, Jr., P.E. D. QUALITY ASSURANCE 1. Miami -Dade Department of Permitting, Environment, and Regulatory Affairs (PERA) E. MATERIAL CERTIFICATIONS 1. Notice of Acceptance No.12-0110.04 issued to Palram Americas, Inc, for their "Corrugated and Flat Polycarbonate Panels", approved on.02/2312012 and expiring on 01/22/2016. 2. Notice of Acceptance No. 08-0305.02 issued to SABIC Innovative Plastics for their "Lexan Sheet Products" approved on 04/24/2008 and expiring on 07/17/2013. 3. Notice of Acceptance No. 10-0329.03 issued to Sheffield Plastics, Inc, for their "Makrolon Polycarbonate Sheets" approved on 07/07/2010 and expiring on 08/27/2012. F. STATEMENTS 1. Statement letter of code conformance to 2010 FBC issued by J & L Wells Consulting LLC, dated 04/25/2012, signed and sealed by James D. Wells, Jr., P.E. "Submitted under NOA # 11-0114, 03" 2. Statement letter of code conformance with FBC 2007 and no financial interest issued by J & L Wells Consulting LLC, dated 03117/2011, signed and sealed by James D. Wells, Jr., P.E. � uiyA.Makar, P.&, M.S. Product Control Section Supervisor NOA No.17-1023.20 Expiration Date: 02/22/2021 Approval Date: 02/2212018 E -1 Sun-Tek Manufacturing, Inc. NOTICE OF ACCEPTANCE: EVIDENCE SUBMITTED 2. EVIDENCE SUBMITTED UNDER PREVIOUS APPROVAL # 15-0513.08 A. DRAWINGS 1. Drawing No. CMA-D-004, titled "CMA-D", sheets I and 2 of 2, dated 0512212000, prepared by the manufacturer, signed and sealed by James D. Wells, Jr., P.E., on 0510412015. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. �IfRami-Dade County Department of Regulatory and economic Resources (PER). E. MATERIAL CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter ofcode conformance to 2014 FBC issued by J & L Wells Consulting LLC, dated 0510512015, signed and sealed by James D. Wells, Jr., P.E. 3. NEW EVIDENCE SUBMITTED A. DRAWINGS 1. Drawing No. CMA-D-004, titled "CMA-D", sheets 1 and 2 of2, dated 0512212000, prepared by the manufacturer, signed and sealed by James D. Wells, Jr., P.E., on 1010612017. B. TESTS 1. None. C. CALCULATIONS 1. None. D. QUALITY ASSURANCE 1. Manti-Dade County Department of Regulatory and economic Resources (RER). E. 1VIATERI4,L CERTIFICATIONS 1. None. F. STATEMENTS 1. Statement letter of code conformance to 2017 FBC issued by J & L Wells Consulting LLC, dated 1010612017, signed and sealed by James D,,j�. Wells, Jr., P.E. p "- d a2 d� HArny A. Makar, P.E., M.S. Product Control Section Supervisor NOA No. 17-1023.20 Expiration Date: 02/22/2021 Approval Date: 02/22/2018 EZ ) & L Wells Consulting LLC 1453 Arbitus Circle T Engineer of Record: Oviedo, FL 32765 James D. Wells, Jr.. P.E. (407) 496-5489 Professional Engineer No.53616 Certificate ofAuthorization No.27162 FOR DETAILS SEE DRAWING CMA—D=004 PAGE 2 OF 2 25.312- I{ I i - 4.000 CMA—D-4689 18 FASTENERS TO CURB IVETS 48 POLY TO ALUM 1 f-- fi.D(T� - Jl 50.6250 MA%. WIDTH I DESIGN PRESSURE RATING +- 60 PSF. LARGE ISSILE IMPACT RESISTANCE 4�e �moP STATE? OF ftORO-' E:V�IS% DWG.N+ CMA-D-004 .118Y7 ATE DOME I18 THK;I( (Polram Palsun, Sheffield Mokmlan or Subic Lexon 9D34) FASTENER SCHEDULE DOME TO CURB i 12 R 2" PHILLIPS PAN HEAD SCREWS RIVET SCHEDULE DOME TO' DECO RING 3/16 % 3/4" POP RIVET MODEL PER LONG SIDE PER SHORT SIDE PER LONG SIDE PER SHORT SIDE 4669 5 4 15 9 4646 4 4 g 9 3636 3069 4 4 3 7 2 7 6 O46 4 3 3030 3 6 6. 2269 5 2 q - - •---------- .. PRODUCT RISVISLL) . Z3 Complying»ifh the Ftorjeh Building. Cod- Acceptanc Exp ;0,09, a4546 F TENER 110 K 2-1//2 SGHIDULE CURB TO DECK DECK SCREWS .MODEL PER LONG SIDE PER SHORT SIDE 4669 0 6 53G38 4 qBy 3069 9 q a roduct Control 3046 5 3 3030 3 3 2269 7 NOTE: ' (1) ALL ROOFING DETAILS SHALL COMPLY WITH CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE (2) 4' MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF ADD TILE HEIGHT AND INSULATION THICKNESS TO 4" MINIMUM HEIGHT. 7LYWOWN47C SHEET ET TMCn 9w. mwb SEe1,1W 9m 0- ar SUCK L". 903a) INNER DOME RISE 5.000 0 U LL a_ HJ n TYPICAL SECTION 1/2 SCALE 19.ODO I DOME RISE 1D' OF SPAN SUN-TEK MANUFACTURING, INC. nWR Nn_ C 4_n—nnn 10303 aENUM UWE "I^00, R 32024 111 Engineer of Record; - J & L Wells Consulting LLC 1453 Arbitus Circle 7¢� • sssis James A Wells, Jr., P.E. Oviedo, PL 32765 0 b Professional Engineer No. 53616 ' (407) 496-5489 Certificate T dtlC STATE OF of Authorization No. 27162 � q SM 0 7 �, +...........� h .71E BV: L. DVG.#,CMA—D-004 c uy'4INgwiththeFlorida #12 x 2" PHILLIPS PAN HEAD SCREW Buill6t8 Cede !/III1111 (5) ON LONG SIDE& (4) ON SHORT SIDE ACCeptance No O Z Deter' (11�/')T,1,oti ,/�/7�///JA fay. 7-K�y-l-7rl._JLV // /'�. OUTER DOME .118 POLYCAR80NATE (Povam Ponan. Saoc Va -Ion an Snctrero Levan Sou) DECO RING 0525 THICK ALUMINUM _ 6063 T5 INSULATED AIR SP CORNERS MITERED & WELDED STI 275 ( \ ao¢ _ INTERIOR. INNER LINER .080 POLYCARBONATE Ie (Pdmm Peisun.She1141a MoYmIan m SP4e Levan 904) MIN. 1.11` c� EMBED 1.11" -►, JJ10 x 2-1/2" DECK SCREW FLASHING FINISHED WALL (8) ON LONG SIDE REQUIRED (4) ON SHORT SIDE NOTE: (1).ALL ROOFING DETAILS SHALL COMPLY WITH •`1 CHAPTER 15 OF THE 2017 FLORIDA BUILDING CODE (2) 4" MINIMUM DISTANCE FROM ANGLE LIP TO ROOF SURFACE IS FOR SHINGLE. OR B.U.R. WITHOUT INSULATION. FOR INSULATION AND TILE ROOF AM ROOF DECK TILE HEIGHT AND INSULATION THICKNESS TO 4" MINIMUM HEIGHT. SILICONE (CONTINUOUS) SEALANT STS 1000 (CONTINUOS) POPPOP Rr5 RNEI 0/LONG SIDE SHORT SIDE I / t MINIMUM SPECIFIC GRAVITY OF CURB WOOD G=D.55 1/4• psolruCon IN.,,gh rod deah R w �^ CMA-D SUN=TEK MANUFACTURING, INC. DArF: . -No- G A-D-004 0503 GENERAL DRAT OR LNfq, rL 32824 N