Loading...
HomeMy WebLinkAboutPRODUCT EVALUATIONWOLTERS ENGINEERING ENGINEERING, DRAFTING, CONSULTING SCANNED BY 15211 97m Road N St. Lucie County West Palm Beach, FL 33412 Ph/Fx:(661)225-1982 PRODUCT EVALUATION PRODUCT: DYNAMIC 1" NAILSTRIP26 GAUGE STEEL ROOF -PANEL (FLPA# 27499.11) MANUFACTURER: DYNAMIC METALS, LLC 340 PIKE ROAD WEST PALM BEACH, FL 33411 To all concerned, The Dynamic 1" Nailstrip 26 Gauge Steel Roof Panel, manufactured by Dynamic Metals LLC, is a non- structural galvalume coated steel roof panel (50 ksi min) that meets the requirements of Sections 1507.4.3 and 1518.9 of the 6"h Edition (2017) Florida Building Code. The panel has been tested per TAS 100 and 125 by Intertek, with results shown in test reports G3443.40.450-44 and G3443.14-450-44. Technical Documentation: 1. • Drawing "NSS16-HZ" dated 6/18118, signed and sealed by Scott Wolters, PE. 2. Test Reports listed above by Architectural Testing, Inc. signed and sealed by Vinu Abraham, PE. 3. Supplemental Calculations to support "NSS.16-HZ' drawing, signed and sealed by Scott Wolters, PE. I have reviewed this submittal per the requirements of FAC Product Approval Rule Chapter 61 G20-3.005 (4). Based on the limitations listed•below and those provided in the documents above, this product meets all the requirements of the 6m Edition (2017) Florida Building Code generally, and chapter 15 specifically, including the HVHZ provisions, Limitations: This panel is approved for use inside and outside of the HVHZ. Overall Limitations: Maximum Panel Width: 16" (nominal) Fastener spacing across panels: 16" O.C. (at nailstrip) (Panels overlap with male/female snap fit) Field Installation Maximum Design Pressure: 116 psf. Max. Fastener Spacing: 2" from ends, 6" max. O.C. Min. Panel Fastener: #10x1" Panclip fastener 5MCIPLIZIN6 IN IMPACf 13;515r*lf CIXrA NWALL5, 5f0lTFRONf5, & WIN70W5 Perimeter and Corner Installation Maximum Design Pressure: 176 psf Panel Clip Anchor Spacing: 2" from ends, 6" max. OL. Min. Panel Fastener: #10x1" Panclip fastener Panel Sealant: Continuous bead of Geoce1.2320 at nailstrip side of seam Underlavment: 1 layer of 30 lb. organic felt paper with 4" overlaps, anchored with .120°x1 '/4" galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C. in rows at the perimeter, at overlaps, and two intermediate rows per sheet.. (or) Any underlayment with a valid FLPA or Miami -Dade NOA Fire Barrier: 1 layer of VersaShield with 4" overlaps, anchored with .120"x1 '/4" galvanized roof nails with 32 Ga. Tin caps spaced 6" O.C. in rows. at the perimeter, at overlaps, and two intermediate rows per sheet. (or) Any fire barrier with a valid FLPA or Miami -Dade NOA Minimum Substrate: 'W (15/32" min) 4-ply CDX Plywood, nailed to 2x rafters spaced 24" max. O.C. with 8d ring -shank nails spaced 4" O.C. Other Limitations: Roof slope must meet requirements of FBC Section 1507.4.2. Fire classification is not a part of this evaluation. Shear diaphragm values are not a part of this evaluation. Design of substrate is by others and is not a part of this evaluation. If you have any questions or need more information concerning this approval please contactme. Thank you, #r Or�295=t c o :* = FL PE# 62354 "� a STATF on to JUN29 ?n18RA 5nCKIZIN6 IN IMPACf M515fANf CI1MNWXL 5, %OWONfS, & WINDOWS