HomeMy WebLinkAboutGENERATOR CONCRETE PADAPR t 2 2019TnittiDepB�Dent St. Lie County PAD THICKNESS GENERATOR ,r I ISOMETRIC VIEW PAD DIMENSIONS: CONCRETE PAD GENERATOR GENERATOR UNIT BY o SEPARATE SUBMITTAL (SEE SCHEDULE FOR H MINIMUM WEIGHT aT I REQUIRED) i 54"LENGTH PLAN VIEW CONCRETE PAD ROAD MESH ASTERFIBER MAC100 3" MIN -C-4" MIN AMERICAST GENERATOR CONCRETE PAD GENERATOR TABLE: (ON -GRADE APPLICATIONS ONLY) AMEN ST •MAIaIDIUCBAOA+• FFD TAXIaGJQIPA2 uC@bE /59i1f050+61 51A+MMm,Ave Can Ne,s.R la9G rLL 1rl-0N-19M F¢ T]a4i14Y0 DaelE aR.9..nw�.Hn.c".,...�nn,uNnM�?..gym"i,e, HVHZ OR NON-HVHZ RISK EXPOSURE EXP RISK EXPOSURE EXP RISK EXPOSURE (EXP) COUNTY I C D II C D III,IV C p P. BEACH 150 MPH 30.44 Psf 36.94 Psf 170 MPH 39.09 Psf 47.44 Psf 380 MPH 43.83 PSI 53.19 Psf BROWARD 156 MPH 32.92 Psf 39.95 Psf 170 MPH 39.09 Psf 47.44 Psf 180 MPH 43.83 Psf 53.19 PSf MIAMI-DADE 165 MPH 36.83 Psf 44.69 Psf 175 MPH 41.43 Psf 50.28 Psf I IRA MPH 46.80 Psf 156.80 Psf BRAND &MODEL CAPACITY WIDTH LENGTH HEIGHT WEIGHT ALLOWABLE PRESSURE COMMENTS Generac 005871 & 005883 10 KW 25.00" 48.00" 29.00" 387 lbs 41.43 PSf EXP C 175 MPH &D 156 MPH Generac 005872 & 005884 14 KW 25.00" 48.00" 29.00" 439 lbs 47.44 Psf EXPC 186 MPH &D 156 MPH Generac 6459, 6461, 6462 16 KW 25.00" 48.00" 29.00" 513 lbs 47.44 Psf Generac006721 16 KW 25.00" 48.00" 29.00" 448 lbs 47.44 Psf Generac OD5873 & 005885 17 KW 25.00" 48.00" 29.00" 4551bs 47.44 Psf Generac 005874 & 005886 17 KW 25.00" 49.00" 29.00" 421 lbs 47.44 Psf Generac 005875 & 005887 20 KW 25.00" 48.00" 29.00" 451lbs 47.44 Psf Generac 006729 & 006730 20 KW 25.00" 48.00" 29.00" 516lbs 47.44 Psf Generac 006551 & 006552 22 KW 25.00" 48.00" 29.00" 526lbs 47.44 PSf Kohler 14RES&20RE5 14-20 KW 26.00" 48.00" 29.00" 500lbs 47.44 Psf GE40323GE&40324GE 13 KW 35.00" 39.40" 39.00" 540lbs 39.09 Psf EXPC 170 MPH &D 156 MPH BE 04038215KW 15 KW 33.00" 49.00" 30.50" 484lbs 43.83 Psf EXP C 180 MPH &D 156 MPH GE 04037817KW 17 KW 33.00" 48.00" 30.50" 484 lbs 43.83 Psf GE 40330GE & 40331GE 20 KW 33.00" 48.00" 30.50" 600 lbs 43.83 Psi Briggs&Stratton 040243-0 IO KW 31.00" 32.00" 34.00" 430 lbs 43.83 Psf Briggs & Stratton 040302-2 12 KW 33.75 " 50.00" 31.60 " 507 lbs 41.43 Psi EXP C 175 MPH & D 156 MPH Briggs & Stratton 040303-1 IS KW 33.75" 49.00" 31.60" 562 lbs 43.83 Psf EXP C 180 MPH & D 156 MPH Briggs & Stratton 040304-1 18 KW 33.75 " 49.00" 31.60 " 568lbs 44.00 Psf Briggs & Stratton 040305-1 20 KW 33.75" 49.00" 31.60" 570lbs 44.00 PSf Generac 7035, 7036, 7037 16 KW 25.00" 48.00" 29.00" 4G6lbs 47.44 Psf EXP C 186 MPH & D 156 MPH Generac 007038 & G07039 20 KW 25.00 " 48.00 " 29.00" 448 lbs 47.44 Psf Generac 007042&7D43 22 KW 25.00" 48.00" 29.00" 466lbs 47.44 PSf GENERATOR MOUNTING CONFIGURATION: GENERATOR GENERATOR ATTACHMENT BASE OR SIMPSON A24 ANGLE BRACE W/ (4) #10 SS 316 SELF -DRILLING SCREWS F ___1 I-F = I 2 GENERATOR (SEE CONCRETE PAD .�., lw SCHEDULE FOR DIMENSIONSWEIGHT REQUIRED) 4" �32" WIDTH -� 54" LENGTH-} SIDE VIEW FRONT VIEW TO GENEW (SEE GENERATOR SF ANCHOR TO PAD SCHEDULE: SUBSTRATE DESCRIPTION CONCRETE: (2)-3/8"0 MEN HD (6000 PSI OR EQUIVALENT, MIN.) 2-3/4" FULL EMBED 0 CONCRETE, 3" MIN EDGE DISTANCE, 6" MIN. SPACING TO ANY ADJACENT ANCHOR. NOTES: 1. ANCHOR QUANTITY PER LONG SIDE 2. EMBEDMENT AND EDGE DISTANCE EXCLUDES FINISHES, IF APPLICABLE. 3. ENSURE MINIMUM EDGE DISTANCE AS NOTED IN ANCHOR SCHEDULE. 4. ENSURE MINIMUM SPACING TO ANY ADJACENT ANCHORS. S. FOLLOW MANUFACTURER'S INSTALLATION INSTRUCTIONS TO INSTALL ANCHORS. GENERATOR ATTACHMENT BASE, VARIES WITH MODEL SEE GENERATOR SPECS SIMPSON TITEN HD, - SEE ANCHOR SCHEDULE 2"X3'xl/e" GALV. STEEL WASHER RUBBER VIBRATION PAD THICK GALVANIZED WASHER&RUBBER VIBRATION PAD CONCRETE PAD - PSI LIGHTWEIGHT CONCRETE PAD X CONCRETE MI% 6,000 PSI N/ LIGHTWEIGHT \ MASTERFIBER MAC 100-/ CONCRETE MIX & ROAD MESH NOTES: FOAM CORE 1. Y DISTANCE DEPEND ON GENERATOR BASE LENGTH, NO LESS THAN 2". 2. X DISTANCE 3" FROM UNIT EDGE TO CLIP. 3. Z DISTANCE DEPEND ON GENERATOR BASE WIDTH, NO LESS THAN ANCHOR REQUIREMENTS t --- 2"--t T i P.E. flu: M. @JBATUSTO, P.E. SIGNATURE ON SHEET 1, HIS SHEET IB PART OF A DIGITALLY SIGNED FILE, SHALL REMAIN IN DIGITAL FORMAT, & PRINTED COPIES OF THIS DOCUMEW ARE NOT CONSIDERED SIUNEI AND SEALED. IF HERE IS NO DESIGN REQUIREMENTS: EE I ITAL SIGNATURE ONWIND as HIS SHEET DOES NOT CONTAIN AN ENGINEER'S ORIGINAL SIGNATURE & SEAL, (BASED ON ASCE 7-10 & FLORIDA BUILDING CODE SIXTH EDITION (2017)) HIS SHEET LS A COPY DRAFT. AT -GRADE SIGN METHOD LID ULTIMATE DESIGN WIND SPEED Vult = 186 mph L..7 a NOMINAL DESIGN WIND SPEED Vasd = 144 mphIT 0 RISK CATEGORY = III INTERNAL PRESSURE COEF = N/A ® w M n Ll 2 EXPOSURE CATEGORY = D WIND DIRECTIONALITY FACTOR Kd= LL F- M i m OO w 0.85 U Wff1 7LL As ujm ENCLOSURE CATEGORY = N/A HEIGHT H - AT GROUND W'En u N x w W GUST EFFECT FACTOR = 0.85 PRESSURE AT HEIGHT H Qh = 77.56 O M au z U "yam Ib/ft2 x Q w LU Lu " w FORCE COEFFICIENT Cf = 1.44 !11 fT J, w w- WIND PRESSURE: UU II. OQ C) Zx 8�m40aff P - Qh G Cf = 56.80 Ib/ft2 (ASD) am N S z ID w WW O,yJ^�wD o who? GENERAL NOTES V) W'iw 1. HIS SYSTEM HAS BEEN DESIGNED AND SHALL BE FABRICATED IN ACCORDANCE WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE W w SIXTH EDITION (2017). n 2. REQUIRED WIND LOAD DESIGN PRESSURES CALCULATED FOR USE WITH HIS SYSTEM SHALL BE DETERMINED UNDER SEPARATE CERTIFICATION ON A JOB -SPECIFIC BASIS IN ACCORDANCE WITH THE GOVERNING CODE. N O C SITE -SPECIFIC LOAD REQUIREMENTS AS DETERMINED IN ACCORDANCE WITH O d HE APPLICABLE BUILDING CODE SHALL BE LESS THAN OR EQUALTO HE 0 DESIGN PRESSURE'ASD' CAPACITY VALUES LISTED HEREIN FOR ANY LD J )~ fX ASSEMBLY AS SHOWN. 3. DIMENSIONS AND WEIGHT OF UNITS SHALL CONFORM TO SPECIFICATIONS J 3 w FE1 jED STATED HEREIN. V Q 1� I, Y Z 4. UNITS MUST BE CENTERED ON PAD WITH OPPOSITE SIDES HAVING EQUAL +A m CLEARANCE. A MINIMUM DISTANCE FROM UNIT TO PAD EDGE IS SPECIFIED. S. CALCULATIONS MADE USING UGMW EIGHT CONCRETE 125 PCF I , 1 .. N V 111 6. THE AREA UNDER CONCERETE SLAB ON GROUND SHALL HAVE ALL I --I z: W r 07 = O VEGETATION, STUMPS, ROOTS, AND FOREIGN MATERIALS REMOVED PRIOR J 1 OI n wO TO INSTALLATION ON COMPACTED SOIL AS VERIFIED BY OTHERS. d ry ZG U W FE 7. RESISTANCE TO SUDING OF HPAD ON THE GROUND IS NOT PART OF THIS DOCUMENT AS SOIL CHARACTERISTICS AND PAD PLACEMENT VARIES. K n J r7 C M O v Z M LL 8. ELECTRICAL GROUND, WHEN REQUIRED, TO BE DESIGNED &INSTALLED BY Y Cc OTHERS. ALL MECHANICAL SPECIFICATIONS (CLEAR SPACE, TONNAGE, ETC.) AND ARE In Q ti N m SHALL BE AS PER MANUFACTURER RECOMMENDATIONS THE EXPRESS RESPONSIBILITY OF THE CONTRACTOR. O 9. ENGINEER SEAL AFFIXED HERETO VALIDATES STRUCTURAL DESIGN AS 1-9 SHOWN ONLY. USE OF THIS SPECIFICATION BY CONTRACTOR, at. al. a INDEMNIFIES& SAVES HARMLESS THIS ENGINEER FOR ALL COST &DAMAGES O INCLUDING LEGAL FEES & APPELLATE FEES RESULTING FROM MATERIAL FABRICATION, SYSTEM ERECTION, CONSTRUCTION PRACTICES BEYOND THAT w a WHICH IS CALLED FOR BY LOCAL, STATE, It FEDERAL CODES Is ROM DEVIATIONS OFTHIS PLAN. 10. WATER-TIGHHESS OF EXISTING FINISHES SHALL BE THE FULL G 0 $ 1YW{239i � o S o u� � RESFONSIBILIY OF THE INSTALLING CONTRACTOR. CONTRACTOR SHALL ENSURE THAT ANY REMOVED OR ALTERED WATERPROOFING MEMBRANE IS RESTORED AFTER FABRICATION AND INSTALLATION OF STRUCTURE Yw7i _ PROPOSED HEREIN. THIS ENGINEER SHALL NOT BE RESPONSIBLE FOR ANY Z WATERPROOFING OR LEAKAGE ISSUES WHICH MAY OCCUR AS LL �€ Sao WATER-TIGHHESS SHALL BE THE FULL RESPONSIBILITY OF THE INSTALLING �000 O g g s .. 'Mo=o CONTRACTOR. 11. THE ROLE OF HIS ENGINEER FOR THIS PROJECT IS THAT OF SPECIALTY;g<w ENGINEER AND NOT THE ENGINEER OF RECORD. CONSEQUENTLY, THE RW ARCHITECT/ENGINEER OF RECORD SHALL BE RESPONSIBLE FOR THE ul3 3 3 INTEGRITY OF ALL SUPPORTING SURFACES TO THIS DESIGN WHICH SHALL BE COORDINATED BY THE PERMITTING CONTRACTOR F B w y b n 6 § 12. THIS DOCUMENT IS GENERIC AND DOES NOT PERTAIN TO ANY SPECIFIC PROJECT SITE. INFORMATION CONTAINED HEREIN IS BASED ON a o ¢ o y u CONTRACTOR -SUPPLIED DATA AND MEASUREMENTS. ENGINEERING EXPRESS ¢ w LL uZ3 C E SHALL NOT BE HELD RESPONSIBLE OR LIABLE IN ANY WAY FOR ERRONEOUS M c OR INACCURATE DATA OR MEASUREMENTS. DIMENSIONS ASHOWN TO52 RE - ' ILLUSTRATE DESIGN FORCES AND OTHER DESIGN CRITERIA. THEY MAY VARY SLIGHTLY, BUT MUST REMAIN WITHIN THE LIMITATIONS SPECIFIED HEREIN. COPYRIGHT ENGIN ERwG EXIRESSa 1--3961,1 WORK SHALL BE FIELD VERIFIED BY OTHERS PRIOR TO CONSTRUCTION. ENGINEERING EXPRESS SHALL BE NOTIFIED AND GNEN AN OPPORTUNITY TO REEVALUATE OUR WORK UPON DISCOVERY OF ANY INACCURATE INFORMATION PRIOR TO MODIFICATION OF EXISTING FIELD CONDITIONS SCALE: NTS UNLESS NOTEC AND FABRICATION AND INSTALLATION OF MATERIALS. ALTERATIONS OR OF ADDITIONS TO THIS DONMENT ARE NOT PERMITTED AND INVALIDATE OUR CERTIFICATION. 13. EXPRESSLY PROVIDED HEREIN, NO DNS r�lLllll OR AFFIRMATIONS OR AFFIRMATIONS ARE INTENDED. v�1�1jH�L./ MY