Loading...
HomeMy WebLinkAboutOPTIOANL LOAD CALCULATIONOptional Load Calculation , • `a —a Heat Larger Than Air C90I&5 SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 Refrigerator @ 1500 Freezer @ 1500 Washing Machine @ 1500 Dishwasher @ 1500 Disposal @ 1500 Mini Sewer @ 1500 Clothes Dryer @ 5000 Range @ 12000 Water heater @ 4500 Fixed microwave @ 1500 Vacuum @ 1500 Trash Compactor @ 1500 Pool Heater @ 'name plate' Spa @'name plate' Motors 746VA per HP Garage Door Opener 1) Total 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 4) Multiply line 3 @ 40% 5) Add lines 2 and 4 6) 60/50amp breakerfor heat (10000) 7) 40/30amp breaker for heat (5000) 8) Total heat -Add lines 6 and 7 9) Multiply line 8 @ 65% 10) Add lines 5 and 9 11) Divide fine 10 by240 Sur"Mary. L ine10 is the total KW 11 is.the totalAmps SCANNED By = CP77qS St Luce County 3000 - /566 A310 L15 l6ovb /3&y5 _ lS458 / 60eX = 60 .= 19 58 (Generator Size Needed) = 9114M (Breaker Size Needed)