HomeMy WebLinkAboutOPTIONAL LOAD CALCULATIONOptional Load Calculation p Heat Larger Than Air (9-3 t 3 SF x 3VA Living Only (2) Small appliance ckts @ 1500VA each Refrigerator @ 1500 Refrigerator @ 1500 Freezer @ 1500 Washing Machine @ 1500 Dishwasher @ 1500 Disposal @ 1500 Mini Sewer @ 1500 Clothes Dryer @ 5000 •Range @ 12000 Water heater @ 4500 Fixed microwave @ 1500 Vacuum @ 1500 Trash Compactor @ 1500 Pool Heater @ 'nameplate' Spa @'name plate' 1, S I, Motors 746VA per HP 1, S b, p ft>cs Garage Door Opener A 1) Total 2) First 10 KVA of general load @ 100% 3) Subtract line 2 from 1 4) Multiply line 3 @ 40% 5) Add lines 2 and 4 6) 60/50amp.breaker for heat (10000) 7) 40/30amp breaker for heat (5000) s) Total heat -Add lines 6 and 7 9) Multiply line 8 @ 65% 10) Add lines 5 and 9 11) Divide line 10 by240 Summary: FUne 101s the total KW 11 is.the total Amps '76aG SCANNED BY .Soo 300o St. Lucie County Lc�a.d S�,e - 1 Svo — Law ,SI•,eCl — Ill�i — ItSc%i bZ3111 - 13117 - 5ILI62,$ ST.LUCIE COUNTY PLAN REVIEW BLDG: DATE: D E. DATE: PLUMB: DATE MECH: DATE: FILE Copy (Generator Size Needed) (Breaker Size Needed)