Loading...
HomeMy WebLinkAboutEVALUATION REPORTCBUCK Engineering Specialty Structural Enc3lnecarinq Evaluation Report "Englert® Series 1101" Metal Roof Assembly Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732)826-8614 for Florida Product Approval # FL 11698.6 R4 CBUCK, Inc Certificate of Authorization Florida Building Code 6th Edition (2017) Method: 1- D Category: Sub - Category: Product: Material: Panel Thickness: Panel Width: Panel Seam: Support: Prepared by: James L. Buckner, P.E., SECB Florida Professional Engineer # 31242 Florida Evaluation ANE ID: 1916 Project Manager: Diana Galloway Report No. 17-135-S1101-S4W-ER (Revises 15.126-SI10144W-ER, F111698.6 R4&R3) Date: 9 / 16 / 17 Contents: Evaluation Report Pages 1-8 Roofing Metal Roofing "Series 1101" Roof Panel Steel 24 gauge 16" Snap -Lock Wood Deck SCANNED BY St. Lucie County Facsimile of digital copy signed by James L. Buckner, P.E. Electranicallysigned and sealed documents shall comply with the provisions of FAC Rule 61G15.23. , 4 ' B BCi � � :'uCEN3F''.•.��i *'• Na 31242 •.*' ­0,n ••.• STATE OF •'• 2017.10.11 13:33:36-04'00' CBUCK, Inc. dba CBUCK Engineering Phone: (561) 491-9927 • Email: cbuck@cbuckincnet • Website: w .cbuckinc.net Business: 1374 Community Dr., Jupiter, FL 33458 • Corp/Mailing: 2637 E. Atlantic Blvd, #34069, Pompano Beach, FL 33062 FL #: FL 11698.6 R4 Date: 9 / 16 / 17 Page Report No.: 2 of 8 51101-saW-ER CBUCK Enc ineen Sp 4=1cs ty Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Manufacturer: Englert, Inc. 1200 Amboy Avenue Perth Amboy, NJ 08862 (732) 826-8614 http://www.englertinc.com/ Product Name: "Series 110V Product Category: Roofing Product Sub -Category Metal Roofing Compliance Method: State Product Approval Rule 611320-3.005 (1) (d) Product/System "Series 1101" Roof Panel Description: 24 gauge steel Nailstrip roof panel mechanically attached to Wood Deck with screws. Product Assembly as Refer to Page 4 of this report for product assembly components/materials & Evaluated: standards: 1. Roof Panel 2. Fasteners 3. Adhesive (select systems) 4. Underlayment S. Insulation (Optional) Support: Type: Wood Deck (Design of support system is outside the scope of this evaluation.) Description: • 15/32" or greater plywood, • or Wood plank (min. specific gravity of 0.42) Slope: Minimum slope shall be: 3 :12 or greater In compliance with FBC Chapter 15 based on the type of roof covering, applicable code sections and in accordance with manufacturer's recommendations. Performance: Wind Uplift Resistance: • Design Uplift Pressure: METHOD 1: - 350 PSF (Refer to "Table A" attachment details herein) METHOD 2: -165 PSF CBUCK Engineering FL #: FL 11698.6 R4 Date: 9 / 16 / 17 Report No.:17-135-S1101-S4W-ER Page 3 of 8 Spedalty Structural Englneerinq CBUCK, Inc. Certificate of Authorization #8064 Performance The product described herein has demonstrated compliance with: Standards: • ULS80-06 —Test for Uplift Resistance of Roof Assemblies • UL 1897-12 — Uplift test for roof covering systems • TAS 12S-03 —Standard Requirements for Metal Roofing Systems Standards Equivalency: The UL 580-94 & UL 1897-98 standard version used to test the evaluated product assembly is equivalent with the prescribed standard UL 580-06 & UL 1897-12 adopted by the Florida Building Code 6th Edition (2017). Code Compliance: The product(s) described herein have demonstrated compliance with the performance standards listed above as referenced in the current Florida Building Code. Evaluation Report This product evaluation is limited to compliance with the structural Scope: requirements of the Florida Building Code, as related to the scope section to Florida Product Approval Rule 61G20-3.001. Limitations and • Scope of "Limitations and Conditions of Use" for this evaluation: Conditions of Use: This evaluation report for "Optional Statewide Approval" contains technical documentation, specifications and installation method(s) which include "Limitations and Conditions of Use" throughout the report in accordance with Rule 61G20-3.005. Per Rule 61G20-3.004, the Florida Building Commission is the authority to approve products under "Optional Statewide Approval'. Option for application outside "Limitations and Conditions of Use" Rule 61G20-3.005(1)(e) allows engineering analysis for "project specific approval by the local authorities having jurisdiction in accordance with the alternate methods and materials authorized in the Code". Any modification of the product as evaluated in this report and approved by the Florida Building Commission is outside the scope of this evaluation and will be the responsibility of others. Design of support system is outside the scope of this report. Fire Classification is outside the scope of Rule 61G20-3, and is therefore not included in this evaluation. This evaluation report does not evaluate the use of this product for use in the High Velocity Hurricane Zone code section. (Dade & Broward Counties) Quality Assurance: The manufacturer has demonstrated compliance of roof panel products in accordance with the Florida Building Code and Rule 61G20-3.0005 (3) for manufacturing under a quality assurance program audited by an approved quality assurance entity through Keystone Certifications, Inc. (FBC Organization ID# QUA 1824). C®UCK Engineering FL #: FL 11698.6 R4 Date: 9 / 16 / 17 Report No.. 17-135-S1101-S4W-ER Page 4 of 8 Specldll'y Structural &ngincerinq CBUCK, Inc Certificate of Authorization 88064 Components/Materials Roof Panel: Englert Series 1101 (by Manufacturer): Material: Steel Thickness: 24 gauge (min.) Panel Widths: 16" (max.) Coverage Rib Height: 1" Yield Strength: 40 ksi min. Corrosion Resistance: Per FBC Section 1507.4.3 Fastener: Type: Pancake -Head Wood Screw Size : #10 x 1" Corrosion Resistance: Per FBC Section 1506.6 and 1507.4.4 Standard: Per ANSI/ASME B18.6.1 Seam Adhesive/Sealant: Product Name: Bostik Chem-Chaulk 915 Type: One component, polyurethane adhesive Application Size: 3/8" bead Application Location: along male flange the full length of panel (Refer to Table "A" and drawing Pg 6-7) Components& Underlayment: Materials: Material and application shall be in compliance with FBC Section 1507.1.1 and in (by Others) accordance with applicable code sections and manufacturer's recommendations. Insulation (Optional): Type: Thickness: Properties: Density: Or Compressive Strength: Rigid Insulation Board 3" (max.) 2.25 pcf (lbs/ft3) min. 20 psi min. Insulation Notes: • Rigid Insulation shall meet minimum density OR compressive strength. • Insulation shall comply with FBC Section 1508. When insulation is incor porated, fastener length shall conform to penetrate thru bottom of support a minimum of 3/16". FL#: FL 11698.6 R4 Date: 9 / 16 / 17 CSUCK Engineering Pagert No.: 5 of g 51101-54W-ER Speciatru Structural Engineering CBUCK, Inc. Certificate of Authorization #8064 Installation: Installation Method: (Refer t0 "TABLE A" below and drawings at the end of this evaluation report.) • Fastener Spacing: Refer to `TABLE W Below (along the length of the panel) • Rib Interlock: Snap -Lock (Panel ribs shall be fully engaged to form an integral snap -lock.) ■ Seam Adhesive: Refer to Table "A" & Drawing Page6. (Apply along male flange the full length of the panel.) • Minimum fastener penetration thru bottom of support, 3/16". • For panel construction at the end of panels, refer to manufacturer's instructions and any site specific design. TABLE "A" ALLOWABLE LOADS METHOD 1 METHOD 2 Design Pressure: -150 PSF -165 PSF Fastener Spacing: 6" O.C. 3" o.c. 3/8" bead Seam Adhesive: Not required (Refer to pg . 6-7) Notes: • Allowable design pressure(s) for allowable stress design (ASD). Install the "Series 1101" roof panel assembly in compliance with the installation method listed in this report and applicable code sections of FBC 6th Edition (2017). The installation method described herein is in accordance with the scope of this evaluation report. Refer to manufacturers installation instructions as a supplemental guide for attachment. Referenced Data: 1. TAS 125 Uplift Test By Architectural Testing, Inc. (FBC Organization ID# TST 1558) Report No. 93745.01-109-18, Date: 11/16/09 Specimens #1-3 2. Quality Assurance Keystone Certifications, Inc. (FBC Organization ID# QUA 1824) Englert, Inc. Licensee #420 3. Equivalency of Test Standard Certification By James L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) 4. Certification of Independence By lames L. Buckner, P.E. @ CBUCK Engineering (FBC Organization # ANE 1916) CBUCK Engineering FL #: FL 11698.6 R4 Date: 9 / 16 / 17 Report No.:17-135-S1301-54W-ER Page 7 of 8 SpeCldlFy Structural Englneering CBUCX, Inc. Certifkate of Authorization #8064 Installation Method Englert, Inc. "Series 1101" (24 gauge Steel) Roof Panel attached to Wood Deck Fastener. 1a oc vvuuu uetx ..........____ __.. .._ _.._ (Refer to Table "A ) Typical Roof Assembly Isometric View (Optional) Rigid Insulation Board per Page 4 of this report TABLE "A" METHOD 1 METHOD 2 Design Pressure: -150 PSF -165 PSF Fastener Spacing: 6" ox. 3" ox. Seam Adhesive: Not required 3/8" bead FL M FL 11698.6 R4 Date: 9 / 16 / 17 g Page Report No.: 6 of g 51101-s4W-ER CSUCK Engineerin SpEeCldlty St rUcturc5l Er7QIr7PPrUlQ CBUCX, Inc. Certificate of Authorization M64 Installation Method Englert, Inc. "Series 1101" (24 gauge Steel) Roof Panel attached to Wood Deck Drawings -r- 3/4" J— Panel Profile 16" o.c. Integral Snap Lock For METHOD 2: Apply 3f8" bead Bostlk Sealant entire length of panel #lox 1" Pancake -Head Screw Typical Assembly Profile View (Typical Fastening Pattern Across Width) CREEK TECHNICAL SERVICES, LLC EVALUATION REPORT Certificate of Authorization No. 29824 17520 Edinburgh Drive Tampa, FL 33647 (813)480-3421 FLORIDA BUILDING CODE, 6'a EDITION Manufacturer: OWENS CORNING ROOFING AND ASPHALT LLC 1 Owens Coming Parkway Toledo, OH 43657 (800)438-7465 www.owenscoming.com Manufacturing Location: Brentwood, NH Houston, TX Quality Assurance: UL LLC (QUA9625) SCOPE Category: Roofing Subcategory: Underlayments Code Sections: 1504.3.1, 1507.1.1 Properties: Physical properties REFERENCES Entity PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Matedals Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Materials Technologies PRI Construction Matedals Technologies Report No. NEI-039-02-01 NEI-042-02-01REV2 NEI-045-02-01 NEI-045-02-01 NEI-053-02-01 NEI-053-02-01 NEI.093-02-D2 OCF-213-02.01 OCF-237-02-01 OCF-252-02-01 OCF-252-02-01 OCF-253-02-02 OCF-272-02-01 OCF-296-02-02 PRI Construction Materials Technologies (TST5878) OCF-297-02-01.1 PRI Construction Materials Technologies (TST5878) OCF318-02-01 PRI Construction Materials Technologies (TST5878) OOF320-02-01 PRI Construction Materials Technologies (TST5878) OCF-32D-02-01 PRI Construction Materials Technologies (TST5878) OCF-321-02-01 PRI Construction Materials Technologies (TST5878) OCF-322-02-01 PRI Construction Materials Technologies (I'ST5878) OCF-356-02-01 'Determined to be equivalent to ASTM D 226-09, Type I and II Issued Oct ,{ z�, , 9D l BY St. Lucie County Standard ASTM D 1970 ASTM D 1970 TAS 103 ASTM G 155 TAS 103 ASTM G 155 ASTM D 1970 ASTM D 1623 UL 1897 ASTM D 4798 ASTM D 1970 ASTM D 1970 TAS 103 ICC-ES AC 188' ICC-ES AC 48 ASTM D 1970 ASTM D 1970 TAS 103 ASTM G 155 ASTM D 1623 UL 1897 UL 1897 Year 2015 2015 1995 2005a 1995 2005a 2015 2009 2012 2001 2015 2015 1995 2012 2012 2015 2015 1995 2005a 2009 2012 2012 OCR14002.8a FL9777-Rl l Pagel of 4 This evaluation report is provided for State of Florida product approval under Rule 61 G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. _ CREEK TECHNICAL SERVICES, LLC PRODUCT DESCRIPTION AND LIMITS OF USE OWENS CORNING ROOFING AND ASPHALT LLC WeatherLock® Self -Seating Ice & Water Barriers WeatherLock® G WeatherLock® G is an ASTM D 1970 self-adhesive undedayment constructed from SBS (Brentwood, NH) modified asphalt, a fiberglass mat reinforcement and surfaced with granules. The product is supplied In 2-sq. rolls with nominal dimensions of 3-ft x 66.7-ft. WeatherLock® G is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roofing coverings. Exposure on the roof deck shall be limited to a maximum 30 days. WeatherLock® Mat WeatherLock® Mat is an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood, NH or SBS modified asphalt with a fiberglass mat reinforcement. The product is supplied in 1- Houston, TX) sq. rolls with nominal dimensions of 3-ft x 33.3-ft and 2 sq. rolls with nominal dimensions of 3-ftx 66.7-ft. WeatherLock® Mat is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. Weatherl-ock® Metal WeatherLock® Metal is an ASTM D 1970 self-adhesive undedayment constructed from (Brentwood, NH) SBS modified asphalt with a fiberglass mat reinforcement and plastic film surface. The product is supplied in 2.0 sq. rolls with nominal dimensions of 3-ft x 56.7-ft.. WeatherLock® Metal is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 90 days. WeatherLock® WeatherLock@ Specialty Tile & Metal is an ASTM D 1970 sell -adhesive undedayment Specialty Tile & Metal constructed from SBS modified asphalt and surfaced with a non -woven polyester fabric. (Brentwood, NH or The product is supplied in 2.14 sq. rolls with nominal dimensions of 3-ft x 71.3-ft. Houston, TX) WeatherLock® Specialty Tile & Metal is permitted to be used as prescribed in FBC Section 1507.1.1. WeatherLock® Specialty Tile & Metal is permitted to be used with adhered clay or concrete tile roofing using either ICP Adhesives Polyset AH-160 (ICP Adhesives and Sealants, Inc.) or TILE BONDr"" Roof Tile Adhesive (The Dow Chemical Company). Exposure on the roof deck shall be limited to a maximum 90 days. The maximum roof slope shall be 6:12 when used with day or concrete file installations without battens. Tile shall be stored on battens for roof slopes greater than 6:12. Tiles shall not be stacked greater 10 tiles per stack. Weathert-ock8i G (High WeatherLock® G (High Tear) is a self -adhered, undedayment used as an alternative to Tear) ASTM D 226, Type I or Type II roofing felt and ASTM D 1970 self -adhering polymer (Houston, TX) modified bitumen underlayment. The undedayment is composed of SBS modified asphalt with a fiberglass mat internal reinforcement and is surfaced with granules. The product is supplied with a nominal thickness of 50 mils in 1.95-sq rolls with nominal dimensions of 3-ft x 65-ft. WeatherLockO G (High Tear) is permitted to be used as prescribed in FBC Section 1507.1.1 for mechanically attached roof coverings. Exposure on the roof deck shall be limited to a maximum 30 days. OCR14002.8a FL9777-RN Page 2 of 4 This evaluation report is provided for State of Florida product approval under Rule 61G20-3. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. } CREEK TECHNICAL SERVICES, LLC PRODUCT APPLICATION Min. Roof Slope: 2:12 in accordance with the FBC OWENS CORNING ROOFING AND ASPHALT LLC WeatherLockO Self -Sealing Ice & Water Barriers Application: All undedayments shall be installed in accordance with the FBC. Deck substrates shall be clean, dry, and free from any irregularities and debris. Alt fasteners in the deck shall be chocked forprotmsion and corrected prior to underlayment application. Prior to beginning installation, the undedayment shall be unrolled and allowed to relax for a minimum of 3-5 minutes. The undedayment shall be installed with the release backer removed and pressed firmly Into place to ensure complete contact with the deck. The underlayment shall be installed with the roll length parallel to the eave, starting at the eave, and with minimum 3" side laps and minimum 6" end laps staggered min. 6-ft,from preceding course. Additionally, if applying WeatherLock® Specialty Tile & Metal, end laps shall be primed with ASTM D 41 primer or sealed with asphalt roof cement a minimum of 3-4 inches across the width of the lap. It is permissible to back nail the undedayment 12-Inches on -center as needed (nails shall be installed perpendicular to deck with the nail heads flush to the top surface of the undedayment). Additionally, WeatherLock® Specialty Tile & Metal shall be back nailed when installed on roof slopes greater than 3:12. Min. Application 40"F; Contact the manufacturer when installing at temperatures below the minimum Temperature: application temperature. WIND RESISTANCE The Maximum Design Pressures shown below were calculated using a 2:1 margin of safety per FBC Section 1504.9 Undedayment System No.1 — WeatherLock SDecialty Tile & Metal Only Roof Deck: Min. 15132-inch CDX plywood attached to wood supports spaced a maximum 24" o.c. Undedayment: WeatherLocidiD Specialty Tile & Metal shall be applied in accordance with manufacturer's installation instructions to the fastened deck and backnailed along the selvage with minimum 12ga., 1-1/4-inch galvanized ring shank roofing nails through optionally primed, 32ga. x 1-5/8-inch 0 fin caps spaced 12" o.c. The applied undedayment shall be rolled with a minimum 751b steel roller immediately following application. Maximum Design -142.5 psf Pressure: OCR14002.Ea 3 of Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein. CREEK TECHNICAL SERVICES, LLC GENERAL LIMITATIONS OWENS CORNING ROOFING AND ASPHALT LLC WeatherLoek® Self -Sealing Ice & Water Barriers 1) This evaluation report is not use in the HVHZ. 2) Fire Classification is not within the scope of this evaluation. 3) Installation of the evaluated product shall comply with this report, the FBC, and the manufacturees published application instructions. Where discrepancies exist between these sources, the more restrictive and FBC compliant Installation detail shall prevail. 4) The roof deck shall be constructed of closely fitted plywood sheathing for new or existing construction. 5) The space under the deck area shall be properly ventilated in accordance with the FBC requirements. 6) All side lap seams shall be installed to shed water from the deck. 7) The undedayment may be used as described in other current FBC product approval documents. 8) Design wind load pressures shall be determined for components and cladding in accordance with FBC 1609. 9) The roof deck shall be designed by others In accordance with FBC requirements to resist the design wind load pressures for components and cladding. 10) Maximum Design Pressures for a given undedayment shall meet or exceed the design wind loads determined for the roof assembly. 11) All products listed in this report shall be manufactured under a quality assurance program in compliance with Rule 61 G20-3. COMPLIANCE STATEMENT The products evaluated herein by Zachary R. Priest, P.E. have demonstrated compliance with the Florida Building Code 6"' Edition (2017) as evidenced in the referenced documents submitted by the named manufacturer. C E IV 8F No 74021 STATE OF AL CERTIFICATION OF INDEPENDENCE 2017.10.1 09:06:29 o-04'00' Zachary R. Priest, P.E. Florida Registration No. 74021 Organization No. ANE9641 CREEK Technical Services, LLC does not have, nor vdll it acquire, a financial interest in any company manufacturing or distributing products under this evaluation. CREEK Technical Services, LLC is not owned, operated, or controlled by any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any company manufacturing or distributing products under this evaluation. Zachary R. Priest, P.E. does not have, nor will acquire, a financial interest in any other entity involved in the approval process of the product END OF REPORT FL9777-Rl of 4 I his evaluation report is provided for State of Florida product approval under Rule 61G203. The manufacturer shall notify CREEK Technical Services, LLC of any product changes or quality assurance changes throughout the duration for which this report is valid. This evaluation report does not express nor imply warranty, installation, recommended use, or other product attributes that are not specifically addressed herein.